- _ _ _ _ _ _ _ _ . _ ._ _ __m_ , _ _ _ _ _ . _ _ . . _ _ . , , _ . _

t U. S. NUcLL AH HLbuL AIUM T 4,,UMMIMivro P.VC 5 oRM 3GG (777)

LICENSEE EVENT REPORT CQ'4 ? POL e LOCK: l l l l l l lh (PLE ASE PRINT CA TYPE ALL REQUIRED INFORMATioN) l lo lil [N ] C j B 1 E I p ] I j@l 0.10 l - LectNSE .

l 0_jNuv oJd0 l 0 l- l010 26 l@l4L,CLN5E 2%

Il ll 11 li j@lb7 CA1 T vFE JJ l

bd l@

l 7 8 9 LiC E *.bE E CODE 94 tt uE ft CON'T lolil 7"y [@[0 ] 5 l 0 l - l o 1312 I SMl fel l 10101517 63 E WENT DATE l a @[1 ] 1 l 0 l 6 l 7 l 86J]@

le 7$ REPORT D AT E 7 8 E,3 61 DOCK ET NWYd E A EVENT DESCRIPTION ANo PROB ABLE CONSEQUENCES h g) A control operator received the control rod drif t alana for rod 10-31. tihen the I rod position display was selected, a false "3" position was superimposed on the f io i3l l actual rod position. I

[c 141 I Io Is] I (Technical Specification 3.1.3.7) 1 l

0 6 l I

o 7 I I

UUa1I 80 E CODE SteC0 E COYPONENT CODE Sue OE $ E lI lD j@ {@ Q@ l C l El T l B l R l K l@ y@ y @

lol91 9 80 ft 12 13 is 19 20 7 8 REVISION SE QUENTI A L OCCURRENCE REPORT

_,EVENTYEAR REPCRT NO. CODE TYPE N O.

@ u"EEn,po' u'i ay [-- j [_0 l 7 l 8 l [.(_) l0 I3 I [.,I.] [---] [Q_]

l217l8l 22 2J 24 26 27 28 29 30 31 32 HOURS SS IT FCA >B. SUPPLI M ANUF ACTUR ER TAK N A TC C 4 PLANT .T

, [,.ZJgl34Cl@

33 , W@ lZl@

34 36 l0l0l0l0l 33 40

[Y 41 j@ W@ W@ lGl0l8l0lh[

42 43 44 47 CAUSE DESCRIPTION AND CCHRECTIVE ACTIONS h I

l i l o l I The position of control rod 10-31 tm 4 nd f only va,-f rf n A hy -fir,3 t he . ~s

,,,,,j to an operabic reed switch position. It was determined that the superimposed "3" l l

, , , position was caused by a ground on thcEPIS probe. The position indication will bc I shutdown. Due to the large number of reed l g g g restored to normal during the next Unit i 4 l switches in use on both Units (14. 248 reed switches), this is considered an f sn1*nda0I co 7 8 9 oTHER STATVS 15 RY DISCOVERY CE5CRIPTION 57  % POWER y [E j@ l 0 l 9 l 7 l@l NA l l B l@l Operator Observation l ACTIVITY CONTENT LOC ATICN OF RELEASE RELEa5ED C# RELE A5E AvouNT of ACTIVITY i c tz_J @ L.:ij@l n i I n 80 I

10 44 45 7 8 9 tt PE# SON'.E L E uPC5u A E5 NU'/af e TYPE l i I 7 I 10 10 10 l@l: l@CE5CaiPTION l n ' '

I i

' ' ' ,E.5C NEl',N;u'4E5

'2 i N o.,. . CESCo ,rie @ -

1 li i s..1 ,10 10 10 l@l>> n .0 I

, ii L0ss CF Ca CavaCE TO F ACIUTY YvPE CESCaiPT CN li 19112 l@l n a ,7/ S 83 I

7 8 9 to NRC USE ONLY

  • "'"*LPT,C @78111b ()4
  • d
121 o l LUutSI

.ss m I 1811111111111 80 = ;

68 69 7 8 9 to sAvEar,nt,Anen A. c. To111 son, Jr. proye: olo-4s7-s701 2,

IIR 1-78-78 Continued event and no further corrective action is required.

I e

i 1

I

( -