NG-94-0819, Ctr Semiannual Radioactive Matl Release Rept for Jul-Dec 1993
ML20064D186 | |
Person / Time | |
---|---|
Site: | Duane Arnold |
Issue date: | 12/31/1993 |
From: | Denise Wilson IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT |
To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
References | |
NG-94-0819, NG-94-819, NUDOCS 9403110071 | |
Download: ML20064D186 (27) | |
Text
. . -.
? .-
lowa Electric Light and Power Company February 25, 1994 NG-94-0819 Mr. John B. Martin Regional Administrator U.S. Nuclear Regulatory Commission Region III 801 Warrenville Road Lisle, Illinois 60532-4351
SUBJECT:
Duane Arnold Energy Center Docket No: 50-331 Op. License No: DPR-49 l
Semi-Annual Radioactive Material Release Report (July 1, 1993 through December 31, 1993)
FILE: A-118e, NRC-7a
Dear Mr. Martin:
Please find enclosed a copy of the Semi-Annual Radioactive Material Release Report for the Duane Arnold Energy Center, Unit No. 1, for the period July 1, 1993 through December 31, 1993. This report satisfies the requirements for the Semi-Annual Radioactive Material Release Report, as stated in Section 6.11.1F of Technical Specifications, (Appendix A to the Operating License DPR-49).
Sincerely, David L. Wilson Plant Superintendent - Nuclear DLW/RL/hc
Attachment:
Semi-Annual Radioactive Material Release Report l cc: Dr. Thomas E. Murley, Director (original w/a) l U.S. Nuclear Regulatory Commissier.
Attn: Document Control Desk )
Mail Station Pl-137 Washington, D.C. 20555 L. Lui (all w/ attachments)
L. Root NRC Resident Office R. Pulsifer (NRC-NRR)
J. Franz P. Bessette DCRC 0 % 141- -
9403110071 931231 ,
PDR ADOCK 05000331 ! '
[
R PDR n .danu JSTRIES Company Duane Arnold Energy Center
- 3277 Dr EC Road
- Palo, Iowa 32324
- 319/831-7611 - \
l
- - - - - - -- .ssa. ~ s. -, a--- .n- z- _ - -- a --- a w- ,-,r,--.
h e
DUANE ARNOLD ENERGY CENTEE SEMI-ANNUAL l
RADIOACTIVE MATERIAL RELEASE REPORT l
l l
JULY 1.1993 THROUGH DECEMBER 31.1993 1
m+-- - w e- A
s.
TABLE OF CONTENTS 1
ITEM PAGE i
TITLE PAGE. . . . . . . . . . . . . . . . . . . . . . . . . . .1 l
l
- TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . , . . .2 1
i j INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . .3 LIQUID EFFLUENT TABLE . . . . . . . . . . . . . . . . . . . . .4 GASEOUS EFFLUENT TABLE. . . . . . . . . . . . . . . . . .. . .5 i
SUMMARY
OF RADIOACTIVE SOLID WASTE. . . . . . . . . . . . .6 - 9 l
i
SUMMARY
OF METEOROLOGICAL DATA COLLECTED. . . . . . . . .10 - 26
.l l
2
.. INTRODUCTION This Semi-Annual Radicactive Material Release Report is for the period of July 1, 1993, through December 31, 1993.
There were no radioactive liquid effluent releases from the Duane Arnold Energy Center during this report period.
Gaseous effluent releases were continuous fcr the period and resulted in site boundary concentrations below 10 CFR 20 limits.
There were no abnormal releases of radioactive material to the environment.
A total of eleven (11) solid radioactive waste shipments were made during the period. Four shipments were spent resin and aqueous mechanical filters and four shipments were irradiated components, all sent directly.for burial at Barnwell, South Carolina. Three shipments were dry activated waste and were sent to Scientific Ecology Group (SEG) for processing at Oak Ridge, Tennessee. One shipment of contaminated liquids was sent to SEG i at Oak-Ridge, Tennessee for incineration.
There were no changes made to the Offsite Dose Assessment Manual or the Process Control Plan.
l I
I l
i i
3
... SEMI-ANNUAL RADIOACTIVE MATERIAL RELEASE REPORT (1993)
.~
LIQUID EFFLUENT Nuclides Released Unit 3rd Quarter 4th Quarter strontium-89 Ci <LLD <LLD strontium-90 Ci <LLD <LLD cesium-134 Ci <LLD <LLD cesium-137 Ci <LLD <LLD iodine-131 Ci <LLD <LLD l
l cobalt-58 Ci <LLD <LLD cobalt-60 Ci <LLD <LLD iron-55 Ci <LLD <LLD iron-59 Ci <LLD <LLD zinc-65 Ci <LLD <LLD manganese-54 Ci <LLD <LLD chromium-51 Ci <LLD <LLD zirconium-nobium-95 Ci <LLD <LLD molybdenum-99 Ci <LLD <LLD technetium-99m Ci <LLD <LLD barium-lanthanum-140 Ci <LLD <LLD cerium-141 Ci <LLD <LLD i
l other (specify) Ci <LLD <LLD Ci <LLD <LLD Ci <LLD <LLD Ci <LLD <LLD 1
l Total for Period (above) Ci <LLD <LLD l xenon-133 Ci <LLD <LLD gxenon-135 Ci <LLD <LLD l
<LLD means that the radionuclide was not identified in any samples and all measurement results were less than the lower limit of detection as required by the DAEC Offsite Dose Assessment Manual.
There were no radioactive liquid discharges from DAEC during this I report period.
i 4
SEMI-ANNUAL RADIOACTIVE MATERIAL RELEASE REPORT (1993)
GASEOUS EFFLUENT Nuclides Released Unit 3rd Quarter 4th Quarter
- 1. Fission Gases krypton-85 Ci <LLD <LLD krypton-85m Ci 6.26E-01 1.98E+00 krypton-87 Ci <LLD <LLD krypton-88 Ci <LLD <LLD xenon-133 Ci 8.72E-01 1.15E+00 xenon-135 Ci 1.19E+01 8.73E-01 xenon-135m Ci 2,62E+00 1.21E+00 xenon-138 Ci <LLD <LLD argon-41 Ci 2.43E-02 1.55E+00 tritium Ci 1.88E+00 2.08E+00 Total for period (above) Ci 1.79E+01 8.84E+00
- 2. Iodines iodine-131 Ci 2.65E-05 3.07E-05 iodine-132 Ci <LLD 1.31E-06 iodine-133 Ci 1.15E-05 4.04E-05 iodine-134 Ci <LLD 7.74E-07 iodine-135 Ci <LLD 9.90E-06 Total for Period Ci 3.82E-05 8.31E-05
- 3. Particulates strontium-89 Ci 1.11E-06 4.92E-06 strontium-90 Ci 1.90E-08 5.15E-07 cesium-134 Ci <LLD <LLD cesium-137 Ci <LLD 1.00E-06 barium-lanthanum-140 Ci <LLD <LLD chromium-51 Ci 8.63E-06 2.10E-05 manganese-54 Ci 3.26E-04 1.33E-04 cobalt-58 Ci 2.04E-05 2.17E-06 iron-59 Ci 1.68E-05 <LLD cobalt-60 Ci 4.',4E-04 4.75E-04 total for Period Ci 8.10E-04 6.38E-04
<LLD means that the radionuclide was not identified in any samples and all measurement results were less than the lower limit of detection as required by the DAEC Offsite Dose Assessment Manual.
5
l l
SUMMARY
OF RADIOACTIVE SOLID WASTE
. (July 1, 1993 - December 31, 1993)
SHIPMENTS MADE TO BURIAL FACILITIES l WASTE TYPE NO. VOLUME ACTIVITY SHIPMENTS M' (C1) l Resin and Aqueous Mechanical 4 17.8 3.45E+02 l Filters l Irradiated Components 4 3.0 5.08E+04 l DESTINATION NO. OF SHIPMENTS Barnwell, South Carolina 8 )
i 1 l
i l
SHIPMENT MADE TO PROCESSING FACILITIES: ;
I l WASTE TYPE NO. VOLUME ACTIVITY l
SHIPMENTS M' (Ci)
Dry Active Waste 3 118.0 4.69E-01 l
(*) Contaminated Liquids 1 7.2 3.13E-04
(*) Contaminated Liquids sent to SEG for Incineration. I I
DESTINATION NO. OF SHIPMENTS l l Scientific Ecology Group (SEG) 4 l Oak Ridge, Tennessee l SOLIDIFICATION AGENT: None MODE OF TRANSPORTATION: Exclusive-Use Vehicle (Trucks)
TOTAL SOLID WASTE DISPOSITION:
l I
l WASTE VOLUME M' ACTIVITY (Ci) l Shipped 138.8** 5.12E+04**
Buried *** 25.1 5.12E+04 l
l (**) Does not include 7.2 m3 of contaminated liquid shipped to SEG for incineration.
(***) Includes waste buried directly by DAEC and waste buried by processing facilities.
l WASTE CLASSIFICATION PER 10 CFR 61 NUMBER OF SHIPMENTS l A-Unstable 4 A-Stable 3 B 1 C 4 l
... i
SUMMARY
OF RADIOACTIVE SOLID WASTE (July 1, 1993 - December 31, 1993)
MAJOR NUCLIDE COMPOSITION DRY ACTIVE WASTE PRINCIPLE 3RD QTR 4TH QTR TOTAL PERCENT NUCLIDES (Ci) (Ci) (Ci) ABUNDANCE Cr-51 0.00E+00 2.69E-03 2.69E-03 0.57 Mn-54 6.21E-03 1.19E-03 7.40E-03 1,58 Fe-55 2.85E-01 2.66E-02 3.12E-01 66.54 Co-58 0.00E+00 5.24E-04 5.24E-04 0.11 Co-60 1.26E-01 1.09E-02 1.36E-01 29.10 Fe-59 0.00E+00 4 89E-04 4.89E-04 0.10 Ni-59 0.00E+00 7.93E-06 7.93E-06 0.00 Ni-63 8.51E-03 6.69E-04 9.17E-03 1.96 H-3 1.20E-07 2.13E-06 2.25E-06 0.00 C-14 3.40E-05 3.48E-05 6.88E-05 0.01 Sr-90 0.00E+00 1.48E-07 1.48E-07 0.00 Tc-99* 1.80E-05 1.80E-05 1.80E-05 0.00 I-129* 1.06E-05 4.37E-05 4.37E-05 0.00 Cs-137 0.00E+00 5.87E-05 5.87E-05 0.01 Pu-241 0.00E+00 6.52E-06 6.52E-06 0.00 Cm-242 0.00E+00 5.37E-08 5.37E-08 0.00 TOTAL 4.26E-01 4.32E-02 4.69E-01 100.00 Lower Limit of Detection (LLD) in units of uCi/ swipe.
NOTE: H-3, C-14, Tc-99, and I-129, were required to be manifested per 10 CFR 20.311.
7
SUMMARY
OF RADIOACTIVE SOLID WASTE (July 1, 1993 - December 31, 1993)
MAJOR NUCLIDE COMPOSITION IRRADIATED COMPONENTS i
PRINCIPLE 3RD QTR 4TH QTR TOTAL- PERCENT NUCLIDES (Ci) (Ci) (Ci) ABUNDANCE i Cr-51 0.00E+00 2.45E+03 2.45E+03 4.82 Mn-54 0.00E+00 1.88E+03 1.88E+03 3.70 Fe-55 0.00E+00 2.86E+04 2.86E+04 56.28 l Co-60 0.00E+00 1.67E+04 1.67E+04 32.83 Ni-59 0.00E+00 6.12E+00- 6.12E+00 0.00 Ni-63 0.00E+00 1.19E+03 1.19E+03 2.35 Nb-94 0.00E+00 1.85E-02 1.85E-02 0.00 l
H-3 0.00E+00 5.34E-02 5.34E-02 0.00 C-14 0.00E+00 1.95E+00 1.95E+00 0.00 I
i Zr-95 0.00E+00 2.24E-04 2.24E-04 0.00 Tc-99 0.00E+00 9.12E-03 9.12E-03 0.00 l Sb-125 0.00E+00 9.47E-03 9.47E-03 0.00 l
I-129* N.P. N.P. N.P. N.P.
Pu-238 0.00E+00 6.91E-04 6.91E-04 0.00 ;
Pu-239/40 0.00E+00 8.86E-07 8.86E-07 0.00 I Pu-241 0.00E+00 1.36E-04 1.36E-04 0.00 Pu-242 0.00E+00 1.21E-09 1.21E-09 0.00 Cm-242 0.00E+00 2.73E-05 2.73E-05 0.00 Cm-243/44 0.00E+00 7.02E-06 7.02E-06 0.00 Am-241 0.00E+00 1.81E-07 1.81E-07 0.00 Am-243 0.00E+00 1.52E-08 1.52E-08 0.00 Np-237 0.00E+00 6.02E-8 6.02E-08 0.00 l l TOTAL 0.00E+00 5.08E+04 5.08E+04 100.00 (N.P.) Not Present NOTE: H-3, C-14, Tc-99 and I-129 were required to be manifested per 10 CFR 20.311.
8
SUMMARY
OF RADIOACTIVE SOLID WASTE (July 1, 1993 - December 31, 1993)
MAJOR NUCLIDE COMPOSITION SPENT RESINS AND AQUEOUS MECHANICAL FILTERS l
PRINCIPLE 3RD QTR 4TH QTR TOTAL PERCENT l (Ci) (Ci) (Ci)
NUCLIDES ABUNDANCE ,
Cr-51 0.00E+00 7.19E+00 7.19E+00 2.08 l Mn-54 0.00E+00 7.20E+01 7.20E+01 20.87 Fe-55 0.00E+00 1.65E+02 1.65E+02 47.94 Co-58 0.00E+00 9.54E+00 9.54E+00 2.76
- Co-60 0.00E+00 8.68E+01 8.68E+01 25.16 Fe-59 0.00E+00 2.11E-01 2.11E-01 0.06 Ni-59 0.00E+00 2.60E-02 2.60E-02 0.01 Ni-63 0.00E+00 1.76E+00 1.76E+00 0.51 H-3 0.00E+00 5.69E-02 5.69E-02 0.02 C-14 0.00E+00 4.20E-01 4.20E-01 0.12 !
Sr-90 0.00E+00 1.73E-03 1.73E-03 0.00 Tc-99* 0.00E+00 1.33E-05 1.33E-05 0.00 I-129* 0.00E+00 1.42E-05 1.42E-05 0.00 Cs-137 0.00E+00 1.60E+00 1.60E+00 0.46 Pu-241 0.00E+00 5.13E-04 5.13E-04 0.00 Cm-242 0.00E+00 6.64E-06 6.64E-06 0.00 TOTAL 0.00E+00 3.45E+02 3.45E+02 100.00 i (LLD) Lower Limit of Detection in units of uCi/gm.
NOTE: H-3, C-14, Tc-99 and I-129 were required to be manifested per 10 CFR 20.311.
l 9
SUMMARY
OF CHANGES QE METEOROLOGICAL DATA The following pages are a summation of meteorological data accumulated during the calendar year 1993 by the MIDAS (Meteorological Information and Dose Assessment) System at the Duane Arnold Energy Center. Each table includes wind speed, wind direction, and stability class at the specified sensor height (33 feet or 156 feet). A summary table of all stability classes at each height is also included.
Data recovery for atmospheric stability, wind speed, and wind direction was 97% or greater at both 33 feet and 156 feet.
10 t
-_- ,- . _ _ . . - . . . . . ~ . - . . .- . . . - - . . . . . .- .., ~ . _ . . . . - - - . .
02/21/94.14:49 SITE: DUANE ARNOLD )
- ' \
HOURS AT EACH WIND SPEED AND. DIRECTION I PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: .A DT/DZ j ELEVATION: SPEED:WS33 DIRECTION:WD33 LAPSE
- DEL T WIND SPEED (MPH) l WIND l
. DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL l
N O O 1 0 0 0 1 I NNE 0- 1 1 0 0 0 2 NE O 7 1 0 0 _0 8: l ENE 1 4 1 0 0 0. 6 E 1 4 2 0 0 0 7 ESE 2 7 4 0 0 0 13 SE 2 20 3 0 0 0 25 l- SSE. 3 22 16 0 0 0 41 S- 1 11 17 1 0 0 30 SSW 0 7 19 -- 8 2 0 36 SW 0 3 16 10 0 0 29 WSW 1 '3 2 6 4 0 17 ;
l W 0 0 1 9 1 0 11 l WNW 1 5 7 11 1 0 25-NW 0 1 10 2 0 0 .13 NNW 0 2 6 3 -0 0 11 l
t TOTAL 12 97 107 50 0 0 275 i l
PERIODS OF CALM (HOURS): 132 VARIABLE DIRECTION O' l HOURS OF MISSING DATA: 263 l l ENTER: (RETURN) CONTINUE,-(SO] START OVER, [EX) TO EXIT t
l l
l i
l l
l 11 l
l._ . , , ,. . , _ . . .__.. _ , - . . - . ,_. _- - - - _.-- _ - . . -
i
.- 02/21/94 14:49 SITE: DUANE ARNOLD HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: B DT/DZ ELEVATION: SPEED:WS33 . DIRECTION:WD33 LAPSE: DEL T WIND SPEED (MPH)
WIND
. DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N O 2 3 0 0 0 5 NNE O 1 2 0- 0 0 4 NE- 2 2 2 0 0 0 6 ENE 1 4 2 0 0 0 7 E O 4 3 0 0 0 7
'ESE 'O 1 3 0 0 0 4 SE O 5 7 0 0 0 12 SSE 4. 13 3 1 0 0 21 S 0 9- 13 2 1 0 25 SSW 0 7 4 6 0 0 17 SW 0 3 3 3 0 0 9 WSW 0 3 3 6 0 0 12 W 1 0 1 0 1 1 4 WNW 0 0 5 10 3 0 18-NW 0 3 10 11 1 0' 25 NNW 0 2 7 6 0 0 15 TOTAL 8 59 71 45 6 1 191 l PERIODS OF CALM (HOURS): 132 VARIABLE DIRECTION O l HOURS OF MISSING DATA: 263 l ENTER: [ RETURN] CONTINUE, (SO) START OVER, (EX] TO EXIT f
l I l i
1 l
l 12 1
, .__- _ ~ . .. . - . - . ..-.. - .. .. . - . . . . - - . . - - . _ - - . - - - -._ .~. - _
. 02/21/94 14:49 SITE: DUANE ARNOLD HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: C DT/DZ ELEVATION: SPEED:WS33 DIRECTION:WD33 LAPSE: DEL T WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL ,
i N 1 2 3 0 0 0 6 l
.NNE O 2 2 0 0 0 4 l
. NE 2 3 3 0 0 0 8 I ENE 2 1 2 0 0 0 5 E O 3 2 0 0 0 5 ESE 1- 5 2 0 0 0 8' SE 1 3 3 0 0 0 ?
SSE 2 7 10 1 0 0 20 S 0 6 8 3 0 0 17 SSW 2 4 5 1 0 0 12 SW 0 3 7 1 0 0 11 WSW 1 4 7 3 4 0 19 W 0 3 6 6 0 0 15 WNW 1 5 6 5 2 0 19 NW 0 5 13 10 1 0 29 NNW 0 6 5 8 1 0 20 TOTAL 13 62 84 38 8 0 205
..................................... ........................ I PERIODS OF CALM (HOURS): 132 VARIABLE DIRECTION O HOURS OF MISSING DATA: 263 ENTER: [ RETURN) CONTINUE, (SO) START OVER, [EX) TO EXIT 13
I i
1
.* 02/21/94 14:50 SITE: DUANE ARNOLD HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 .)
STABILITY CLASS: D DT/DZ ~
l ELEVATION: SPEED:WS33 DIRECTION:WD33 LAPSE: DEL T i ....__........_..........__............... __.. ................
WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 20 -33 31 6 0 0 94 NNE 7 33 27 6 4 0 77' NE. 13- 74 72 11 0 0 171 ENE 12 67 28 3 0 0 110 E 24 83 27 0 0 0 134 ESE 16 85 34 3 0 0 139 SE 19 81 67 4 0 0 172 l SSE 13 72 79 22 0 0 186 S 18 77 92 27 0 0 214 SSW 4 38 48 -16 3 0 109 SW 16: 27 30 16 0 0 89 WSW 15 61 42 20- 3 0 141 W 8 47 88 27 7 0 177 WNW 6 75- 130 88 20 0 322 NW 9 98 179 91 20 1 406 NNW 7 41 134 90 14 0 294 TOTAL 207 992 1108 430 71 .1 2835 PERIODS OF CALM (HOURS) : 132
' VARIABLE DIRECTION O HOURS OF MISSING DATA: 263 ENTER: (RETURN] CONTINUE, (SO) START OVER, [EX] TO EXIT l
.I i
J i
14
. ~ . . . . - - .. . .._ . . =- . . _ - . - . - . .
l-
+ l c
02/21/94 14:50 SITE: DUANE ARNOLD !
l HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASSt E -DT/DZ ELEVATION: SPEED:WS33 DIRECTION:WD33 LAPSE: DEL T '
...................._..._................................_...... I WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 43 92 22 7 0 0 166 a NNE 37 51 61- 31 1 0 183 NE 21 93 50 20 5 0 199 ENE 45 90 46 17 0 0 198 E 66 154 30 0 0 0 251 ESE 36 146 63 4 0- 0- 249 SE' 63 146 47 5 0 0 262 ;
SSE 68 155 94 12 0 0 329 S 36 154 139 22 0 0 352 '
SSW 44 77 46 6 0 0 173 SW 19 37 34 9 0 0 100-WSW 28 50 42 11 1 0 133 W 23 66 38 16 0 0 143 WNW 24 100 83 27 1 0 237 NW 9 109 95 13 1 0 232 i
NNW 13 54 83 20 1 0 171 TOTAL 575 1574 973 220 10 0 3378
- PERIODS OF CALM (HOURS) : 132 VARIABLE DIRECTION O HOURS OF MISSING DATA: 263
' ENTER: [ RETURN] CONTINUE, [SO) START OVER, (EX} TO EXIT l
1 15
. _ _ . - __ ._ _ ., _ . . - _ _ _ _ - _ . - . . . . _ . _.._.m . _ . . _ _ - . _ _ . _ . ~
J l
1 l
02/21/94 14:51 SITE: DUANE ARNOI D I
HOURS AT EACH WIND SPEED AND DIRECTION '
2 PERIOD OF RECORD = 93010101-93123124 .
l STABILITY CLASS: F DT/DZ I
. ELEVATION: SPEED:WS33 DIRECTION:WD33 LAPSE: DEL T WIND SPEED (MPH) '
! WIND I
DIRECTION 1-3 47 8-12 13-18 19-24 >24 TOTAL N 7 4 1 1 0 0 15 NNE 17 21 13 11 2 1 68 NE 22 34 18 14 2 0 91 l
ENE 29 35 21 3 0 0 89 E- 25 27 17 1 0 0 76 ESE 22 21 6 1 0 0 56 SE 42 32 0 1 0 0 77 SSE 46 45 4 0 0 0 95 <
S 52 36 13 0 0 0 102 SSW 61 41 8 0 0 0 110 SW 36 27 3 0 0 0 67 )
WSW 21 18 3 0 0 0 42 t W 18 14 1 1 1 0 36 WNW 16 22 5 0 0 0 44 NW 10 14 6 1 0 0 32 NNW 10 8 11 2 0 0 31 TOTAL 434 399 130 36 5 1 1031 PERIODS OF CALM (HOURS); 132 VARIABLE DIRECTION 0-HOURS OF MISSING DATA: 263 ENTER: [ RETURN) CONTINUE, [SO) START OVER, [EX) TO EXIT l
l l
16 1
i l
l 02/21/94 14:51 SITE: DUANE ARNOLD !
HOURS AT EACH WIND SPEED AND DIRECTION l PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: G DT/DZ ELEVATION: SPEED WS33 DIRECTION:WD33 LAPSE: DEL T WIND SPEED (MPH)
WIND DIRECTION 'l-3 4-7 8-12 13-18 19-24 >24 TOTAL N 5 'l 0 2 1 0 12 NNE 18 6 4 17 2 0 48 NE -41 21 1 0 0 0 63 ENE 39 1 3 2 0 0 45 E 29 4 4 0 0 0 45 l ESE 20 5 3 0 0 0 46 SE 44 1 0 0 0 0 47 SSE 49 8 0 -0 0 0 62 S 40 3 4 'O O O 48 SSW 45 7 3 0 0 0 59 SW 32 6 0 0 0 0 42 WSW 16 3 0 0 0 0 20 W 12 2 0 0 0 0 15 WNW 2 0 0 0 0 0 4 NW 5 4 0 0 0 0 10 ;
NNW 4 0 1 11 0 0 16 TOTAL 401 72 23 32 3 0 582 PERIODS OF CALM (HOURS): 132
. VARIABLE DIRECTION O HOURS OF MISSING DATA: 263 ENTER: (RETURN] CONTINUE, (SO] START OVER, (EX] TO EXIT l i i
' l.
l i
i l
17 i l
I
[ .I l
. m . _ _ _ ._ .- . _ - - - _ _ _ . _ . _ - _ _ . _ . .
i
\. .
j
." 02/21/94 14:51 SITE: DUANE ARNOLD .i i
HOURS AT EACH WIND SPEED AND DIRECTION .)
PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: ALL DT/DZ <
ELEVATION: SPEED:WS33 DIRECTION:WD33 LAPSE: DEL T WIND SPEED (MPH)
WIND
- DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL j i
i N 76 134 61 16 1 0 299 NNE 79 115 110 65 9 1 386 ;
'- NE 101 234 147 45 7 0 546 l
l ENE 129 .202 103 25 0 -0 460 l E 145 279 85 1 0 0 525 ESE 97 270 115 8 0 0 515 SE 171 288- 117. 10 0 0 602 SSE 185 322 206 36 0 0 754 5 147 296 286 55 1 0 788 SSW 156 181 133 37 $. 0 -516 SW 103 106 93 39 0 0 347 WSW 82 142 99 46 12 0 384 W 62 132 135 59 10 1 401
( WNW 50 207' 236 141 27 0 669 NW 33 234 313 128 23 1 747 NNW 34 113 247 140 16 0 558 TOTAL 1650 '3255 2496. 851 111 3 8497 PERIODS OF CALM (HOURS): 132
! VARIABLE DIRECTION 3 l t HOURS OF MISSING DATA: 263 l ENTER: (RETURN] CONTINUE, [SO] START OVER, [EX] TO EXIT i
r i
i
(
I l
l b
18 i
l' l
L
l 02/21/94-14:53 SITE: DUANE ARNOLD i
l HOURS AT EACH WIND SPEED AND DIRECTION
! PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: A DT/DZ i ELEVATION: SPEED:WS156 DIRECTION:WD156 LAPSEtDEL T 1 I
WIND GPEED (MPH) l WIND l DIRECTION- '1-3 4-7 8-12 13-18 19-24 >24 TOTAL
! N O 1 1 0 0 0 2
~ NNE O 1 2 0 0 0 3 i
i NE O 6 4 0 0 0 10 i l ENE O 3 0 1 0 0 4 E 2 3 2 0' 1 0 8.
ESE O 3 5 5 .0 0 13 SE 1 8 7 1 0 0 17 l SSE 2 11 13 11 0 0 37 l S 0 7 14 13 0 0 34-SSW 4 3 5 16 7 2 37 SW 1 1 1 23 7 0 33 WSW 0 4 1 6 6 1 18-W 0 0 1 5 0 0 6 WNW 2 4 3 7 7 .0 23 NW D 4 9 4 2 0 19 NNW 0 1 5 4 1 0 11 TOTAL 12 60 73 96- 31 3 275 PERIODS OF CALM (HOURS) : 37 VARIABLE DIRECTION O HOURS OF MISSING DATA: 226 l ENTER: (RETURN] CONTINUE, [SO] START OVER, [EX] TO EXIT l
l l
19 l
02/21/94 14:53 SITE: DUANE ARNOLD '
HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS:. B DT/DZ ,
ELEVATION: SPEED:WS156 DIRECTION WD156 LAPSE: DEL T WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL j
'N- 0 2 3 4 0 0 9 NNE O 1 1 0 0 0 2 NE 1 4 3 0 0 0 9 ENE O 2 3 0 0 0 5 E O 3 -2 1 0 0 6 ESE O O 3 1 0 0 4 SE 2 4 3 6 0 0 15 i SSE 2 7 6 2 1 0 18 S 2 5 8. 4 2 0 21 I
SSW 2 3 3 9 0 0 17 SW .0 3 2 1 4 1 11-WSW 2 1 5. 6 1 1 16 W- 0 0 1 1 0 0 2 WNW 2 2 4 6 4 1 19 '
NW 0 4 3 12 5 3 27 NNW 0 0 3 8 0 0 11 TOTAL 13 41 53 61 17 6 191
' PERIODS OF CALM (HOURS): 37 VARIABLE DIRECTION O HOURS OF MISSING DATA: 226 ENTER: [ RETURN] CONTINUE, [SO] START OVER, [EX) TO EXIT -
20
.. = . . . . . .. . _. .
02/21/94 14:53 SITE: DUANE ARNOLD HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: C DT/DZ LELEVATION: SPEED:WS156 DIRECTION:WD156 LAPSE: DEL T WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24' TOTAL f N O 1 3 3 0 0 '7 .
- NNE 1 0 2 0 0' O 3 j NE O 5 5 1 0 0 11 ENE 1 1 0 0 0 0 2 ;
E 1 2 4 1 0 0 8 !
ESE O 1 3 2 0 0 6 SE O 5 'l 1 0 0 7 SSE 2 1 0 9 1 0 21 j S 1 1 7 5 1 0 15 SSW 0 3 2 6 0 0 11 SW D 1 6 3 1 0 11 WSW '2 2 4 6 1 4 19 -
a W 1 4 5 7 0 0 17 WNW 3 2 3 5 4 0 17 NW 0 4 8 20 3 1 36 NNW 0 3 4 6 1 0 14 TOTAL 12 36 65 75 12 5 205 ;
PERIODS OF CALM (HOURS): 37 VARIABLE DIRECTION O HOURS OF MISSING DATA: 226 ENTER: [ RETURN] CONTINUE, [SO) START 'EX] TO EXIT I
l 1
21
i i- '
l 02/21/94 14:53 SITE: DUANE ARNOLD l HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 I STABILITY CLASS: D DT/DZ, ELEVATION: SPEED:WS156 DIRECTION:WD156 LAPSE: DEL T WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 24 36 29 13 4 1 107 i NNE 11 36 54 32 5 1 139 l j NE 10 38 51 23 2 0 124 l l ENE 12 35 38 17 0 0 103 1 l i E 10 50 72 12 0 0 144 ESE 13 44 59 23 5 2 146 i SE 6 31 58 42 5 7 143 j SSE 14 31 62 62 22 4 195 j 49 66 198 S 5 68 10 0 l SSW 12 18 41 35 4 1 111
! SW 4 30 27 29 11 0 101 )
i WSW 20 33 44 23 8 0 128 I W 10 40 65 42 17 4 178 i
WNW 6 55 90 112 50 16 329 NW 4 64 141 155 69 20 453 l NNW 7 32 82 108 20 3 252 l TOTAL 168 622 979 796 232 53 2851 PERIODS OF CALM (HOURS) 37 VARIABLE DIRECTION O HOURS OF MISSING DATA: 226 ENTER: [ RETURN) CONTINUE, (SO) START OVER, [EX] TO EXIT i
22
. - - - - . _ ~ . - -. . . _ . _ - . - - - - - _ _ _ _ _ _ _ _ _
i.
a..
02/21/94 14:54 SITE: DUANE ARNOLD HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: E DT/DZ ELEVATION: SPEED WS156 DIRECTION:WD156 LAPSE: DEL T WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 56 58 38 32 2 0 186 I NNE 15 28 78 64 22 0 207 NE 15 67 65 40 12 2 201 ENE 22 55 55 26' 1 0 167 i E 56 56 114 23 0. 0 '249 i ESE 7 53 127 43 4 1 235 l SE 9 56 124 49 8 0 246 l SSE 8 38 126 88 17 0 278 S 4 65 143 117 17 0 346 SSW 20 46 94 38 3 0- 201 SW 6 43 32 26 7 0 -114 WSW 11 36 30 29 5 1 115 W 6 47 45 36 14 0 148 WNW 24 78 -83 63 IO 1 259 NW 9 42 125 51 13 3 244 NNW 12 34 105 49 .1 0 201 TOTAL 280 802 1384 774 136 8 3397 l
j PERIODS OF CALM (HOURS) : 37 VARIABLE DIRECTION 0 l HOURS OF MISSING DATA: 226 l ENTER: [ RETURN] CONTINUE, [SO) START OVER, [EX) TO EXIT '
'l ;
I i
i 1
23 1.
i l l I
I
_ _ _ _ . = . . . . . _ . _ . . . . . _ . . . _ . _ . . ._ _ . . . . _ _ _ _ _ _ . _ _ . . ..__ _ _ _ __ _ _ _ . _ _
02/21/P4 14:54 SITE: DUANE ARNOLD l HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: F DT/DZ ;
ELEVATION: SPEED:WS156 DIRECTION:WD156 LAPSE DEL T l
WIND SPEED (MPH)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL j
N 10 11 5 3 1 0 31- l 10 03 11 13 27 21- 7 1 80 i NE 9 27 43 19 6 2 106 ENE 17 31 20 1 1 0 73 E 5 34 12 13 1 0 68 ESE 6 9 16- 6 0 0 37 i SE 8 17 27 5 0 1 58 SSE 4 19 51 3 0 0 77 ]
S 5 22 28 12 1 0 68
'SSW 12 29 22 8 0 0 73 SW 8 39 29 7 0 0 83 WSW 6 30 22 1 0 0 62 i W 7 29 21 1 2 0 60 )
, WNW 8 30 16 4 0 0' ~ 58 l NW 4 22- 22 4- 2 0 54 NNW~ 11 & 21 3 0 0 43 TOTAL 131 370 382- 111 21 4 1031 -)
PERIODS OF CALM (HOURS): 37 VARIABLE DIRECTION O l HOURS OF MISSING DATA: 226 ENTER: (RETURN] CONTINUE, (SO] START OVER, [EX] TO EXIT l
i 24 4
1
- - - ~, ,_ . - ~ ,m . , . , _ _ , . , _ -...-._ , ,, ..--,,n,, , - _ -,7,-y- . . , -
1 l
02/21/94 14:54 SITE: DUANE ARNOLD
' HOURS AT EACH WIND SPEED AND DIRECTION PERIOD.OF RECORD = 93010101-93123124
, STABILITY CLASS: G DT/DZ ELEVATION: SPEED:WS156 DIRECTION:WD156- LAPSE: DEL T WIND SPEED (MPH)
' WIND DIRECTION 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 12 22 3 6 9 0 52
.NNE 17 15 17 6 5 0 61 1 NE 14 9 6 1 0 0 30 l ENE 14 4 4 2- 0 0 2 5 .-
l- E 17 9 2 2 0 0 33 j ESE 16 20 6 4 0 0 46 l SE. 8 18 5 0 0 0 31 SSE 14 30 15 2 0 0 67 S 9 28 7 4 0- 0 '48 l SSW 25 19 3 0 0 0 47
, SW 10 7 6 0 0 0 23 WSW '10 7 3 0 0 0 20 l W 3 13 4 0 0 0 20
! 1067 11 8 4 0 0 'O. 23 NW 7' -10 3 0 0 0 20 NNW 17 6 3 2 10 0 38 l
'l TOTAL 204 225 91 29 24 0 584 '
l PERIODS OF CALM (HOURS): 37 j VARIABLE DIRECTION O HOURS OF MISSING DATA: 226 ENTER: [ RETURN] CONTINUE, [SO) START OVER, [EX] TO EXIT l l 1
I .
l l
l' 25 l
02/21/94 14:54 SITE: DUANE ARNOLD HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD = 93010101-93123124 STABILITY CLASS: -ALL DT/DZ
-ELEVATION: SPEED:WS156 DIRECTION:WD156 LAPSE: DEL T WIND SPEED (MPH)
WIND
, DIRECTION. 1-3 4-7 8-12 13-18 19-24 >24 TOTAL N 102 131 82 61 16 1 394' NNE 55 94 181' 123 39 2 495
.NE 49 156 177 84 20 4 490 ENE 66 131 120 47 2 0 379 E 91 157 208 52 2 0 516 ESE 42 130 219 84 9 3- 487 SE 34 139 225 104 13 2 517 SSE 46 137 281 177 41 '4 693 S 26 177 273 223 31 0 730 SSW 75 121' 170 112 14 3 497 SW 29 124 103 89 30. 1 376 WSW 51 113 109 71 21 7 378-W 27 133 142 92 33 4 431 WNW 56 179 203 197 75 18 728 l NW 24 150 311 246 94 '27 853 NNW 47 84 223 180 33 3 570 TOTAL 820 2156 3027 1942 473 79 8534
.. _.........._ ....___... ....._............................. 1 PERIODS OF CALM (HOURS) : 37 VARIABLE DIRECTION 0 j HOURS OF MISSING DATA: 226 ENTER: [ RETURN] CONTINUE, [SO] START OVER, [EX] TO EXIT l
i I
i l- 26 i
- , - - .- , , ,-