Text

__

@ HAZLECON ENVIRONMENTAL SCIENCES C'\\

A CMSION OF HAZLETON LABCAATORES AMEAICA,INC.

V mOG FAONTAGE ACAO, NORTHBACOK. ILLINOIS 60062. U S.A.

REPORT TO IOWA ELECTRIC LIGHT AND POWER CEDAR RAPIDS, IOWA ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM FOR THE DUANE ARNOLD ENERGY CENTER CEDAR RAPIDS, IOWA Docket No. 50-331 O

ANNUAL REPORT - II DATA TABULATIONS AND ANALYSES i

v l

FEBRUARY - DECEMBER 1982 PREPARED AND SUBMITTED BY HAZLETON ENVIRONMENTAL SCIENCES PROJECT NO. 8001-101

(

i l

Approved by:

3-4/A L. G. Rcebner, M.S.

Director, Nuclear Sciences l

l 22 February 1983 e304040400 e30320 PDR ADOCK 05000331 R

PDR AMONE (3121564-0700 o TELE X 28-9403 (M AZES NBAK)

HAZLETON GNVIRIINMINTAL. SCIENC'.Q OLJ PREFACE The staff members of the Nuclear Sciences Department of Hazleton Environmental Sciences (HES), a Division of Hazleton Laboratories America, Inc. (HLA), were responsible for the acquisition of data presented in this report. All environ-mental samples were collected by personnel of DAEC.

The report was prepared by C. R. Marucut, Section Supervisor, Nuclear Sciences, under the direction of L.

G.

Huebner, Director, Nuclear Sciences. She was assisted in the report preparation by L. Nicia, Group Leader, and other staff members of the Nuclear Sciences Department.

O O

i

-. ~. _

=.

4 HAZLETON QNVIRONMHNTAL ECCNC33 TABLE OF CONTENTS No.

Page PREFACE 11 LIST OF TABLES iv

1.0 INTRODUCTION

1 2.0 DATA TABLES 8

Appendices A

Crosscheck Program Results A-1 B.

Data Reporting Conventions B-1 0

l l

l F

O i11

HAZLETON ENVIRONMENTAL CCl2NC3I3 A'(,)

LIST OF TABLES No.

Title Page 1

Sampling locations, Duane Arnold Energy Center 3

2 Type and frequency of collection 6

3 Sample codes used in Table 2 8

4 Airborne particulates collected at Location D-1 (Cedar Rapids), analysis for gross beta 9

5 Airborne particulates collected at Location D-2 (Marion),

analysis for gross beta 10 6

Airborne particulates collected at Location D-3 (Hiawatha),

analysis for gross beta 11 7

Airborne particulates collected at Location D-4 (Johnson),

analysis for gross beta 12 8

Airborne particulates collected at Location D-5 (Palo),

analysis for gross beta 13 9

Airborne particulates collected at Location D-6 (Center Point), analysis for grosc beta 14 10 Airborne particulates collected at Location D-7 (Shellsburg),

analysis for gross beta 15 11 Airborne particulates collected at Location D-8 (Urbana),

analysis for gross beta 16 12 Airborne particulates collected at Location D-9 (Route W26),

analysis for gross beta 17 13 Airborne particulates collected at Location D-10 (Atkins),

analysis for gross beta 18 14 Airborne particulates collected at Location D-11 (Toddville),

analysis for gross beta 19 15 Airborne particulates collected at Location D-12 (Iowa City),

analysis for gross beta 20 16 Airborne particulates collected at Location D-13 (Alburnett),

analysis for gross beta 21 17 Airborne particulates collected at Location D-14 (Alice sub-pd station), analysis for gross beta 22 iv

HA2LETON CNVIRONMZNTAL Sci:NCEJ LIST OF TABLES (continued)

No.

Title Page 18 Airborne particulates collected at Location D-15 (On-site, north), analysis for gross beta 23 19 Airborne particulates collected at Location D-16 (On-site, south), analysis for gross beta 24 20 Airborne particulate samples, quarterly composites of weekly samples, analysis for strontium-89, strontium-90, and gamma-emitting isotopes 25 21 Charcoal samples, weekly composites from indicator locations D-4, D-5, D-7, D-11, and 0-15; analysis for iodine-131 33 22 Charcoal samples, weekly composites from control locations D-8, D-12, and D-14; analysis for iodine-131 34 23 Ambient gamma radiation (TLD), monthly exposure 35 24 Ambient gamma radiation (TLD), annual exposure 43 p

25 Milk samples collected during the non-grazing season, analysis C

for iodine-131 44 26 Milk samples collected during the grazing season, analysis for iodine-131 and gamma-emitting isotopes 45 l

27 Milk samples collected during grazing season, analysis for strontium-89, strontium-90 and elemental calcium 52 28 Ground water samples, analysis for gross beta 55 29 Ground water samples, quarterly composites of monthly samples, 57 analysis for gross beta and tritium 30 Vegetation samples (brcad leaf), analysis for iodine-131 59 31 Vegetation samples (grain), analysis for strontium-90 and gamma-emitting isotopes 60 32 Meat and poultry samples, analysis for gamma-emitting isotopes 64 33 Wildlife samples, analysis for gamma-emitting isotopes 65 34 Soil samples, analysis for strontium-90 and gamma-emitting isotopes 66 O

V

HAZLETON CNVIRONMINTAL GCGNC30 O

LIST OF TABLES (continued)

No.

Title Page 36 Surface water samples, analysis for gamma-emitting isotopes 73 37 Surface water samples, quarterly composites of monthly samples, analysis for gross beta, tritium, strontium-89, and strontium-90 80 38 Fish samples, analysis for gamma-emitting isotopes 81 39 Periphyton samples, analysis for gamma-emitting isotopes 83 40 River sediment samples, analysis for strontium-90 and gamma-emitting isotopes 85 41 Precipitation samples, analysis for gross beta and tritium 87 O

I l

bv vi

HAZLETON CNVIRONMINTAL ECIENC23 O

1.0 Introduction The following consists of data tabulations and analyses for the Annual Reprot - Part II for the 1982 Environmental Radiological Monitoring Prograni conducted at the Duane Arnold Energy Center, Cedar Rapids, Iowa.

A summary with interpretation of the data presented here is contained in a separate report to the Iowa Electric Light and Power Company.

' O O

1

HAZLETON ENVIRONMENTAL. SCCNC2O Table 1.

Sampling locations, Duane Arnold Energy Center.

Sampling Location Distance and Code Type" Sampling Location Direction from Point Description Site Stack D-1 C

1 Cedar Rapids 11 mi 0 135* SE D-2 C

2 Marion 11 mi 0 125* SE D-3 3

Hiawatha 7 mi 0 130* SE i

D-4 4

Johnson 3 mi 0 140* SE D-5 5

Palo 3 mi 0 200* SW D-6 6

Center Point 7 mi 0 0* N 0-7 7

She11sburg 6 mi 0 255* W D-8 8

Urbana 9 mi 0 345* NW D-9 9

Route W26 7 mi 0 295* NW D-10 10 Atkins 8 mi 0 210' SW D-11 11 Toddville 4 mi 0 90* E D-12 C

12 Iowa City 25 mi 0 160* S D-13 C

13 Alburnett 8 mi 0 70* NE D-14 14 Alice Substation 7 mi 0 35* NE D-15 15 On-site, North 0.5 mi 0 305* NW D-16 16 On-site, South 0.5 mi 0 190* S D-17 17 0.5 mi N i

D-18 18 0.5 mi NE J

D-19 19 0.5 mi NE D-20 20 0.5 mi NE D-21 21 0.5 mi E D-22 22 0.5 mi SE D-23 23 0.5 mi SE D-24 24 0.5 mi S D-25 25 0.5 mi SW D-26 26 0.5 mi SW D-27 27 0.5 mi SW D-28 28 0.5 mi SW D-29 29 0.5 mi SW D-30 30 0.5 mi W 0-31 31 0.5 mi NW D-32 32 0.5 mi NW D-33 33 3.0 mi N D-34 34 3.0 mi NE D-35 35 3.0 mi NE D-36 36 3.0 mi NE D-37 37 3.0 mi E D-38 38 3.0 mi SE D-39 39 3.0 mi SE D-40 40 3.0 mi SE D-41 41 3.0 mi S D-42 42 3.0 mi SW D-43 43 1.0 mi SW 2

HAZLETON GNVIRONM2NTAL CCl2NC'.CO

)

Table 1.

(continued)

Sampling Location Distance and Code Type" Sampling Location Direction from Point Description Site Stack D-44 44 1.0 mi SW D-45 45 1.0 mi SW D-46 46 1.0 mi W D-47 47 1.0 mi NW D-48 48 1.0 mi NW D-49 C

49 Lewis access, upstream of DAEC D-50 50 Plant Intake D-51 51 Plant Discharge D-52 52 Cedar Rapids City Park 7.5 mi SE D-53 53 Treated Municipal Water D-54 54 Inlet to Municipal Water Treatment System D-55 55 On-site Well D-57 57 Bull (Off-site well)

D-58 58 Frantz Fam, 0.5 mi of DAEC D-59 59 Frantz Farm, 0.5 mi of DAEC D-60 60 Wiley, Off-site within 1.0 mi of DAEC D-61 61 One-half mile down-stream of plant discharge D-63 63 Andrews Fam,1.5 mi NW D-72 72 Van Note Fam, within 2 miles of site, SW l

D-73 C

73 Hansen Fam, within i

22 miles of site D-76 76 0.5 mi NE D-77 77 0.5 mi NE D-78 78 0.5 mi NE D-79 79 0.5 mi E D-80 80 0.5 mi SE D-81 81 0.5 mi SE l

l 3

l

Ha7E FTON ENVIRONMSNTAL CCGNCO2 Table 1.

(continued)

Sampling Location Distance and Code Type

  • Sampling Location Direction from Point Description Site Stack D-82 82 0.5 mi SE D-83 83 0.5 mi S D-84 84 0.5 mi SW D-85 85 0.5 mi SW D-86 86 0.5 mi SW D-87 87 0.5 mi SW D-88 88 0.5 mi W D-89 89 0.5 mi W D-90 90 0.5 mi NW D-91 91 0.5 mi N 0-93 93 Yarborough Fam 2.8 mi of site, NW D-94 94 Hines Farm 2.7 mi NE D-96 96 Keiper Fam 7.5 mi SW D-99 99 Pleasant Creek 2.2 mi NW D-101 101 Flecksing Fam 4.0 mi NE D-102 C

102 McCardle Farm 20.0 mi NW D-103 103 Park Pond 1.5 mi E D-104b 104 Jim Miller Fann 1.2 mi NE D-105 C

105 Schulte Farm 21.3 mi SW D-106 106 David R. Stallman 4.5 mi SE a"C" denotes control location. All other locations are indicatocs.

Location D-104 was dropped frca the program effective 8-24-82 and was replaced by location D-106 O

4

HAZLETON ENVIRONMENTAL SCENCEJ Table 2.

Type and frequency of collection.

Loc.

S eni-Location Type" Weekly Monthly Quarterly Annually Annually D-1 C

AP TLD TLD D-2 C

AP TLD TLD D-3 AP TLD TLD D-4 AP,AI TLD TLD D-5 AP,AI D-6 AP TLD TLD D-7 AP,AI TLD TLD D-8 AP,AI TLD TLD D-9 AP TLD TLD D-10 AP TLD TLD D-11 AP,AI TLD TLD D-12 C

AP,AI TLD TLD D-13 C

AP TLD TLD D-14 AP,AI TLD TLD D-15 AP,AI TLD S0b TLD D-16 AP TLD S0b TLD D-17-48 TLD TLD D-49 C

SW SL F,BS D-50 SW BS D-51 SW BS p

V D-52 SW D-53 WWc D-54 WWd D-55 WW D-57 WW S0bse D-58 WW S0bse D-59 WW D-60 WW 0-61 SL F,BS D-63 Mf S0b Ge D-72 Mf S0b G8 D-73 C

SW D-76-91 TLD TLD l

D-93 Mf S0b Ge D-94 Mf S0b ge,ME D-96 Mf S0b ge D-99 SW O

5

HAZLETON CNVIRONMENTAL SCCNCTO Table 2.

(continued)

Loc.

Semi-Location Type" Weekly Monthly Quarterly Annually Annually D-101 Mf S0bse D-102 C

Mf S0b Ge,ME D-103 SW D-1049 S0b Ge D-105 C

Mf S0bse D-106 Mf S0b ge On-site P

Inside 10 mile radius of plant WL

  • Control locations are indicated by a "C" in this column. All other locations are indicators.

b Soil is collected three times per year.

cd Collected hourly and composited monthly and quarterly.

Collected daily and composited monthly and quarterly, e Vegetation (G) includes broad leaf vegetation and grain.

f Monthly from October through April; weekly from May through September.

\\

9 D-104 was dropped from the program starting 8-31-82 and was replaced by location D-106.

I O

6

_ =.

HA71 INTON CNVIRUNMINTAL CCIINC!!3 Table 3 Sample codes used in Table 2 Code Description AP Airborne Particulates AI Airborne Iodine TLD Thermoluminescent Dosimeter P

Precipitation M

Milk WW Well Water G

Vegetation (broad leaf and grain)

E Meat and Poultry SO Soil SW Surface Water F

Fish SL Periphyton (aquatic biota)

BS River Sediment WL Wildlife l

lO l

7

.,g.

HAZLETON ENVIRONMZNTAL CCIENC'IG O

2.0 DATA TABLES O

l l

f I

I 8

)

HAZLETON ENViptONMZNTAL. SCIENC]'3 Table 4.

Airbcrne particulates collected at Loce. tion D-1, (Cedar Rapids),

analysis for gross beta. Collection: Weekly.

Date Volume Gross Beta Date Volume Gross Beta Collected (m )

(pCi/m3)

Collected (m )

(pCi/m3) 3 3

1-07-82 287 0.061i0.005 7-08-82 242b 0.024i0.004 1-14-82 281 0.04810.004 7-15-82 285 0.02610.003 1-21-82 281 0.048i0.004 7-22-82 286 0.022i0.003 1-28-82 281 0.036i0.004' 7-29-82 287 0.034i0.004 2-04-82 284 0.045i0.004 8-05-82 283 0.03210.004 2-11-82 281 0.050t0.005 8-12-82 285 0 02310.003 2-18-82 287 0.056i0.005 8-19-8?

286 0.035i0.004 2-25-82 292 0.02510.003 8-26-82 287 0.032i0.004 3-04-82 284 0.023i0.003 9-02-82 277 0.017*0.003 3-11-82 283 0.033i0.004 9-09-82 277 0.016i0.003 3-18-82 285 0.014i0.003 9-16-82 268 0.014i0.003 3-2E-82 286 0.014i0.003 9-23-82 280 0.021i0.004 4-01-82 283 0.020i0.003 9-30-82 276 0.033i0.004 1st Qtr. mean i s.d.

0.036i0.016 3rd Qtr. mean i s.d.

0.025t0.007 4-08-82 286 0.029i0.003 10-07-82 276 0.023i0.004 4-15-82 289 0.031i0.004 10-14-82 278 0.015i0.003 4-22-82 284 0.019i0.003 10-21-82 274 0.028i0.004 4-29-82 284 0.029i0.004 10-28-82 279 0.023i0.004 5-06-82 284 0.034i0.004 11-04-82 287 0.023i0.003 5-13-82 284 0.033i0.004 11-1L 82 286 0.029i0.004 5-20-82 287 0.023i0.003 11-18-82 285 0.03410.004 5-27-82 300 0.012i0.003 11-24-82 242b 0.037i0.003 6-03-82 298 0.018i0.003 12-02-82 329c 0.033i0.003 6-10-82 294 0.018i0.003 12-09-82 286 0.026i0.003 6-17-82 287 0.033i0.005 12-16-82 286 0.03010.003 6-24-82 293 0.017i0.003 12-22-82 243b 0.022i0.003 7-01-82 52a 0.038i0.014 12-30-82 326c 0.023i0.003 2nd Qtr. mean i s.d.

0.026i0.008 3rd Qtr. mean t s.d.

0.027i0.006 Pump ran for only 28 hours3.240741e-4 days <br />0.00778 hours <br />4.62963e-5 weeks <br />1.0654e-5 months <br />.

b Pump ran for 6 days.

c Pump ran for 8 days.

O 9

,m_._

L HAZLETON ENVIRONMENTAL. SCCNCE'3 x

gv

+ p

/

r

  • be Tab 1 5.

'Airbdrne particulates collected at Location D-2, (Marion) 2 analysis far gross beta. Collection: Weekly.

./

Date

- Volume.

Gross Bgta Date Volyme Gross Bgta Collected,- (m3) p (pC1/m4)

Collected (m3)

(pci/m4) t.1-07-82

.' 1927 O.058*0.005 7-08-82 287 0.016i0.003 1-14-82, 285 0.0$110.004 7-15-62 285 0.020f0.003 1-21-82

'285,

'?O.052i0.004 7-22-82 287 0.013i0.003 J,284 ;

0'.035t0.004 7-29-82 286 0.016i0.003 pfm 1-2G-82 7

-285'

. 0.048i0.1104 t.-05-82 293 0.027*0.003

/2 h04-62

^

L 7/

M 1?o2

' 283

- 0.052*0:005 8-12-82 293 0.01610.003 i/

t J2-18.02.

286,

0.053t0.005 8-19-82 286 0.03110.004

/'- / ' 2-26-02' 289'-

<0.02210.003 0-26-82 286 0.028i0.004

. c3-04-8't.

283 0'033*0.004 9-02-82 282 0.019i0.003 4

3-11-82,, f 28?:

0.046tn.004 6 9-09-82 285 0.015*0.003

/'

.'3-18-82'/, 487 '. C'0.017tG'.003 9-16-82 285 0.018i0.003

'/. p 7q$25 42n #, 285, '

01020t6.'003 9-23 288 0.012t0.003 i

,.. 0:025t0.003 9-30-82 284 0.028i0.003 4-01-82

?.86.

9, j'

v;,

n..

' 41st-Qtr. m an i s.d.i 0.03910'.014 3rd Qtr. mean i s.d.

0.020io.006 1

~

y

- y

, i,

,e v

.-v J4-08-EC M 256.. ' O.029i0.003 e

10-07-82 285 0.026i0.004

/

./ ~;4-15-827,, f289*~'O037i0.004 10-1982 284 0.012i0.003 4-20-82i,

"?84" J. : 0.'023*0.003 e ' 10-21:32 286 0.019i0.003 r

4 29fE2+>

'28i',

-4 0.036+0.004 '

+

/g -'5-06-82 }

284-0.02810.004-10-28-82 285 0.026i0.004 e

11-04-82 287 0.019i0.00's e s

~*

5-13-82 285 '. 0.023i0.003

'11-11-8; 297 0.011*0.003 0.021*0.003 11-18-82 284.

0.032i0.004 5-20-82 287

~.: 27-82,

204 3 0.01010.003*-

11-25-02 243a 0.035*0.004 6-03-82 /

286 ' ~ 0.014i0.0.03 12-02-82 329b 0.020f0.003 285 7 / 0.014i0.003.

12-09-82 286 0.027tG.003

'6-10-82
  • 6:.17-82

' 285 '

.0.024*0.004 12-16-82 284 0.030i0.003

'6-24-82 285l 0.011i0.003 12-22-82 244a 0.023i0.004 7 /

?-01-82 28h' 0.025 0.003 12-30-82 326b 0.022i0.003

(

2nd Qtr. mean i 9 4.

0.022i0.009 <,' '

4th Qtr. mean i s.d.

0.023i0.007 y

a

[

=

1 ab. Pump 'ran for 61 dad

.,. Pum9 ran for 8 day:1.

.<~

y LC l

10 l

I

HAZl.ETON ENVIRONMENTAL SCENCE]

p Table 6.

Airborne particulates collected at Location D-3, (Hiawatha) analysis for gross beta.

Collection:

Week 1).

Date Volume Gross Bgta Date Volyme Gross Bgta Collected (mJ)

(pCi/m3)

Collected (m3)

(pC1/m4) 1-11-82 450a 0.042i0.003 7-08-82 286 0.02110.003 1-14-82 122b 0.039*0.007 7-15-82 285 0.023i0.003 1-21-82 285 0.049i0.004 7-22-82 286 0.020i0.003 1-28-82 284 0.03810.004 7-29-82 287 0.032t0.004 2-04-82 285 0.04710.004 8-05-82 284 0.032i0.004 2-11-82 285 0.057i0.005 8-12-82 286 0.020*0.003 2-18-82 286 0.076i0.005 8-19-82 285 0.034i0.004 2-25-82 290 0.02910.003 8-26-82 287 0.025i0.004 3-04-82 285 0.02910.004 9-02-82 284 0.022i0.003 3-11-82 283 0.045i0.004 9-09-82 285 0.01910.003 3-18-82 286 0.018i0.003 9-16-82 285 0.019i0.003 3-25-82 286 0.023i0.003 9-23-82 287 0.021i0.003 4-01-82 286 0.02410.003 9-30-82 284 0.041*0.004 1st Qtr. mean i s.d.

0.040i0.016 3rd Qtr. mean i s.d.

0.025i0.007 l

4-08-82 285 0.025i0.003 10-07-82 286 0.031*0.004 x

4-15-82 290 0.047i0.004 10-14-82 285 0.011i0.003 4-22-82 284 0.030f0.004 10-21-82 287 0.021i0.004 4-29-82 283 0.040f0.004 10-28-82 285 0.021i0.003 5-06-82 285 0.03410.004 11-04-82 287 0.020*0.003 5-13-82 284 0.028i0.004 11-11-82 285 0.02410.003 5-20-82 286 0.02410.003 11-18-82 286 0.027IO.003 5-27-82 285 0.012i0.003 11-25-82 243c 0.031i0.004 6-03-82 286 0.01410.003 12-02-82 328d 0.025t0.003 6-10-82 285 0.016i0.003 12-09-82 282 0.022i0.003 6-17-82 286 0.03210.005 12-16-82 279 0.024i0.003 6-24-82 285 0.014i0.003 12-22-82 241c 0.023i0.004 7-01-82 286 0.019i0.003 12-30-82 326d 0.023i0.003 2nd Qtr. mean i s.d.

0.026i0.011 4th Qtr. mean i s.d.

0.023i0.005 Pump ran for 11 days.

Collection was delayed because of snow storm.

b l

Pump ran for only 3 days.

c Pump ran for 5 days.

d Pump ran for 8 days.

l 11

HAZLETON CNVIRONMENTAL SCENCEJ C) ra,le 7.

,,,,o,ne,a,ticuiates coiiected at tocat,on 0 4, (ao,nson) analysis for gross beta.

Collection: Weekly.

Vol p)

(pC1/m3)

Gross 8gta Date Volume Gross Bgta Date Collected (m3)

(pCi/m3)

Collected (m3 1-07-82 297 0.048*0.004 7-08-82 286 0.017i0.003 1-14-82 292 0.047i0.004 7-15-82 287 0.018i0.003 1-21-82 297 0.04710.004 7-22-82 284 0.01310.003 1-28-82 291 0.03410.004 7-29-82 287 0.02810.004 2-04-82 296 0.04210.004 8-05-82 284 0.026i0.003 2-11-82 294 0.053t0.005 8-12-82 285 0.020i0.003 2-18-82 291 0.02710.004 8-19-82 285 0.03010.004 2-25-82 297 0.023i0.003 8-26-82 288 0.02710.004 3-04-82 284 0.02710.003 9-02-82 283 0.018t0.003 3-11-82 283 0.041i0.004 9-09-82 286 0.018i0.003 3-18-82 286 0.017i0.003 9-16-82 285 0.020t0.003 3-25-82 283 0.018i0.003 9-23-82 286 0.014t0.003 4-01-82 285 0.021i0.003 9-30-82 285 0.023i0.003 1st Qtr. mean i s.d.

0.034i0.013 3rd Qtr. mean i s.d.

0.021*0.005 4-08-82 285 0.026t0.003 10-07-82 285 0.027*0.004 hq 4-15-82 285 0.032i0.004 10-14-82 285 0.01110.003 4-22-82 288 0.023i0.003 10-21-82 285 0.022*0.004 4-29-82 282 0.024i0.003 10-28-82 286 0.025i0.004 5-06-82 282 0.027i0.004 11-04-82 287 0.022i0.003 5-13-82 287 0.027*0.003 11-11-82 286 0.027i0.004 5-20-82 290 0.021i0.003 11-18-82 285 0.031i0.004 5-27-82 286 0.010i0.003 11-25-82 245a 0.026i0.004 6-03-82 287 0.014i0.003 12-02-82 327b 0.029i0.003 6-10-82 299 0.016i0.003 12-09-82 286 0.020i0.003 6-17-82 285 0.026i0.004 12-16-82 285 0.020i0.003 6-24-82 292 0.015i0.003 12-22-82 245a 0.003i0.003c 7-01-82 308 0.015i0.003 12-30-82 327 0.004i0.002c 2nd Qtr. mean i s.d.

0.021i0.007 4th Qtr. mean i s.d.

0.021*0.009

$Pumpranfor6 days.

Pump ran for 8 days.

c Filter paper very light. Very little air particulate matter on the filter.

12

MAZLATON ENVIRONMENTAL CCl!NCE3 Table 8.

Airborne particulates collected at Location D-5, (Palo), analysis for gross beta. Collection:

Weekly.

Gross Beta Date Volyme Gross Bgta Vol p)

(pCi/md)

Collected (m3)

(pCi/m3)

Date (m3 Collected 1-07-82 288 0.050f0.004 7-08-82 286 0.017f0.003 1-15-??

329a 0.050i0.004 7-15-82 289 0.018i0.003 1-21-82 240b 0.053i0.005 7-22-82 114c 0.011i0.006 1-28-82 285 0.041*0.004 7-29-82 288 0.031i0.004 2-04-82 295 0.057i0.005 8-05-82 283 0.029i0.004 2-11-82 276 0.06710.005 8-12-82 285 0.022i0.003 2-18-82 285 0.07810.006 8-19-82 285 0.03210.004 2-25-82 288 0.021i0.003 8-26-82 287 0.025i0.004 3-04-82 285 0.022i0.003 9-02-82 243d 0.01710.003 3-11-82 283 0.038i0.004 9-09-82 286 0.016i0.003 3-18-82 286 0.015i0.003 9-16-82 285 0.01810.003 3-25-82 283 0.016i0.003 9-23-82 286 0.016i0.003 4-01-82 285 0.019i0.003 9-30-82 285 0.030i0.004 1st Qtr. mean i s.d.

0.041i0.021 3rd Qtr. mean i s.d.

0.022i0.007 4-08-82 286 0.028i0.003 10-07-82 285 0.032i0.004 4-15-82 285 0.033i0.004 10-14-82 285 0.013i0.003 4-22-82 289 0.018io.003 10-21-82 285 0.01910.003 4-29-82 279 0.034*0.004 10-28-82 285 0.024i0.004 5-06-82 288 0.030t0.004 11-04-82 287 0.018i0.003 5-13-82 281 0.02210.003 11-11-82 285 0.024i0.003 5-20-82 285 0.023i0.003 11-18-82 285 0.024i0.003 5-27-82 279 0.012i0.003 11-25-82 245b 0.027i0.004 6-03-82 284 0.017i0.003 12-02-82 3268 0.025i0.003 6-10-82 282 0.015i0.003 12-09-82 286 0.022i0.003 6-17-82 287 0.022i0.004 12-16-82 285 0.02110.003 6-24-82 282 0.017i0.003 12-22-82 245b 0.019i0,004 7-01-82 284 0.015i0.003 12-30-82 3278 0.019i0.003 2nd Qtr. mean i s.d.

0.022i0.007 4th Qtr. mean i s.d.

0.02210.005

$Pumpranfor8 days.

Collection was delayed because of snow storm.

I Pump ran or 6 days.

c Low volume due to pump malfunction.

g Pump ran for only 143.1 hrs. Started 8-27-82.

e Pump ran for 8 days.

13

HAZLETON ENVIRONMENTAL SCENCO3 Table 9.

Airborne particulates collected at Location D-6, (Center Point),

analysis for gross beta.

Collection: Weekly.

Date Volyme Gross Bgta Date Volume Gross Bgta 3

d Collected (m3)

(pCi/m3)

Collected (m )

(pCi/m )

1-07-82 299 0.051i0.004 7-08-82 280 0.01810.003 1-14-82 281 0.044t0.004 7-15-82 291 0.022i0.003 1-21-82 307 0.048i0.004 7-22-82 29a 0.027i0.021 1-28-82 304 0.041i0.004 7-29-82 283 0.020i0.003 2-04-82 301 0.046i0.004 8-05-82 278 0.018i0.003 2-11-82 303 0.048i0.004 8-12-82 281 0.019i0.003 2-18-82 290 0.038i0.004 8-19-82 284 0.03610.004 2-25-82 294 0.02410.003 8-26-82 287 0.026i0.004 3-04-82 297 0.024i0.003 9-02-82 283 0.018i0.003 3-11-82 290 0.03810.004 9-09-82 286 0.01810.003 3-18-82 290 0.013i0.003 9-16-82 287 0.021i0.003 3-25-82 285 0.01810.003 9-23-82 285 0.020i0.003 4-01-82 285 0.021i0.003 9-30-82 285 0.033i0.004 1st Qtr. mean i s.d.

0.035i0.013 3rd Qtr. mean i s.d.

0.023t0.006 4-08-82 281 0.02610.003 10-07-82 286 0.034i0.004 O.

4-15-82 288 0.033i0.004 10-14-82 285 0.014i0.003 4-22-82 289 0.021t0.003 10-21-82 285 0.022i0.004 4-29-82 271 0.035*0.004 10-28-82 286 0.026t0.004 5-06-82 284 0.025i0.003 11-04-82 287 0.022i0.003 5-13-82 287 0.019i0.003 11-11-82 283 0.02110.003 5-20-82 285 0.020*0.003 11-18-82 276 0.035i0.004 5-27-82 283 0.01210.003 11-25-82 238b 0.036i0.004 6-03-82 282 0.019i0.003 12-02-82 320c 0.027i0.003 6-10-82 278 0.017i0.003 12-09-82 286 0.028i0.004 l

6-17-82 288 0.02410.004 12-16-82 285 0.028i0.003 6-24-82 279 0.016i0.003 12-22-82 244b 0.02210.004 7-01-82 281 0.01610.003 12-30-82 344c 0.019i0.003 2nd Qtr. mean i s.d.

0.022i0.007 4th Qtr. mean i s.d.

0.026t0.007 Low volume caused by blown fuse.

b Pump ran for 6 days.

c Pump ran for 8 days.

O 14

HAZLETCN ENVIRONMENTAL. SCENC~T3 3

(O Table 10.

Airborne particulates collected at Location D-7, (Shellsburg),

analysis for gross beta.

Collection: Weekly.

Date Vol me Gross B ta Date Vol me Gross Beta 3

Collected (m )

(pCi/m)

Collected (m )

(pCi/m) 1-07-82 235 0.047*0.004 7-08-82 282 0.017*0.003 1-14-82 284 0.041i0.004 7-15-82 285 0.02310.003 1-21-82 284 0.045i0.004 7-22-82 280 0.018i0.003 1-28-82 293 0.034i0.004 7-29-82 287 0.032i0.004 2-04-82 284 0.04710.004 8-05-82 286 0.030f0.004 2-11-82 284 0.046i0.005 8-12-82 285 0.019i0.003 2-18-82 282 0.050i0.005 8-19-82 285 0.03610.004 2-25-82 274 0.021i0.003 8-26-82 286 0.028i0.004 3-04-82 265 0.024t0.004 9-02-82 285 0.021i0.003 3-11-82 303 0.030i0.003 9-09-82 286 0.018i0.003 3-18-82 286 0.012i0.003 9-16-82 285 0.018i0.003 3-25-82 283 0.015i0.003 9-23-82 286 0.018i0.003 4-01-82 286 0.018i0.003 9-30-82 285 0.033i0.004 1st Qtr. mean i s.d.

0.03310.014 3rd Qtr. mean i s.d.

0.024i0.007 p

4-08-82 285 0.022i0.003 10-07-82 285 0.035t0.004 d

4-15-82 285 0.030i0.004 10-14-82 285 0.01210.003 4-22-82 289 0.02610.003 10-21-82 286 0.021i0.004 4-29-82

?87 0.024i0.003 10-28-82 285 0.027i0.004 5-06-82 285 0.027i0.004 11-04-82 287 0.023i0.003 5-13-82 284 0.023i0.003 11-11-82 285 0.029i0.004 5-20-82 286 0.021i0.003 11-18-82 285 0.03410.004 5-27-82 284 0.010i0.003 11-25-82 245a 0.036i0.004 6-03-82 286 0.018i0.003 12-02-82 327b 0.031i0.003 6-10-82 285 0.018i0.003 12-09-82 286 0.032i0.003 6-17-82 286 0.01910.004 12-16-82 285 0.029i0.003 6-24-82 289 0.015i0.003 12-22-82 245a 0.02110.004 7-01-82 296 0.015i0.003 12-30-82 326b 0.025i0.003 2nd Qtr. mean s.d.

0.021i0.006 4th Qtr. mean i s.d.

0.027i0.007

" Pump ran for 6 days.

Pump ran for 8 days.

O 15

HAZLETON ENVIRONMENTAL. CClZNC'))

Table 11.

Airborne particulates collected at Location D-8, (Urbana),

analysis for gross beta.

Collection: Weekly.

Volgme Gross Bgta Date Volyme Gross Bgta Date (m )

(pC1/m) 3 Collected (m3)

(pCi/m )

Collected 3

1-07-82 288 0.04810.004 7-08-82 286 0.016i0.003 1-14-82 284 0.042i0.004 7-15-82 285 0.019i0.003 1-21-82 284 0.043i0.004 7-22-82 286 0.011i0.003 1-28-82 285 0.038i0.004 7-29-82 287 0.020i0.003 2-04-82 285 0.03910.004 8-05-82 284 0.021*0.003 2-11-82 285 0.042i0.004 8-12-82 285 0.013i0.003 2-18-82 285 0.043i0.004 8-19-82 292 0.039i0.004 2-25-82 286 0.022i0.003 8-26-82 304 0.023i0.003 3-04-82 286 0.022i0.003 9-02-82 283 0.013i0.003 3-11-82 283 0.027i0.003 9-09-82 286 0.01710.003 3-18-82 286 0.004i0.002a 9-16-82 291 0.01710.003 3-25-82 286 0.011i0.002 9-23-82 285 0.01810.003 4-01-82 286 0.013i0.003 9-30-82 290 0.032i0.004 1st Qtr. mean i s.d.

0.030i0.015 3rd Qtr. mean i s.d.

0.02010.008 l

l 4-08-82 285 0.012i0.003 10-07-82 290 0.02410.004 0-4-1s-82 28s o ote*o oo3 to-14-82 281 o o12*o oo3 4-22-82 288 0.019i0.003 10-21-82 285 0.021i0.004 4-29-82 296 0.034i0.004 10-28-82 285 0.02810.004 5-06-82 267 0.01910.003 11-04-82 287 0.02010.003 5-13-82 284 0.023t0.003 11-11-82 285 0.019i0.003 5-20-82 286 0.017i0.003 11-18-82 285 0.007*0.002a 5-27-82 284 0.011i0.003 11-25-82 245b 0.032i0.004 l

6-03-82 286 0.012i0.003 12-02-82 327c 0.015i0.003 6-10-82 285 0.013t0.003 12-09-82 286 0.019i0.003 6-17-82 286 0.022i0.004 12-16-82 285 0.023i0.003 6-24-82 285 0.014i0.00?

12-22-82 245b 0.011*0.003 7-01-82 286 0.012i0.003 12-30-82 327c 0.020i0.003 2nd Qtr. mean i s.d.

0.017i0.006 4th Qtr. mean i s.d.

0.01910.007

  1. Filter paper very light. Small amount of air particulate matter on the filter.

b Pump ran for 6 days.

c Pump ran for 8 days.

16

HAZLETON ENVIRONMENTAL SCIZNCE]

Table 12.

Airborne particulates collected at Location D-9, (Route W26),

analysis for gross beta.

Collection: Weekly.

Date Volyme Gross Bgta Date Volyme Gross Bgta Collected (m3)

(pCi/md)

Collected (m3)

(pCi/m )

a 1-07-82 273 0.046i0.004 7-08-82 294 0.018i0.003 1-14-82 265 0.044i0.004 7-15-82 291 0.019i0.003 1-21-82 265 0.04610.004 7-22-82 293 0.013i0.003 1-28-82 270 0.04210.004 7-29-82 294 0.027f0.004 2-04-82 254 0.046i0.005 8-05-82 283 0.021*0.003 2-11-82 252 0.052i0.005 8-12-92 259 0.019t0.003 2-18-82 259 0.052i0.005 8-19-82 300 0.02910.004 2-25-82 288 0.023i0.003 8-26-82 280 0.028i0.004 3-04-82 282 0.02010.003 9-02-82 290 0.01810.003 3-11-82 278 0.02710.003 9-09-82 287 0.014i0.003 3-18-82 287 0.012i0.003 9-16-82 285 0.014i0.003 3-25-82 288 0.01410.003 9-23482 277 0.019i0.003 4-01-82 287 0.020i0.003 9-30-82 287 0.030f0.004 1st Qtr. mean i s.d.

0.034i0.015 3rd Qtr. mean i s.d.

0.021t0.006

s 4-08-82 285 0.023i0.003 10-07-82 289 0.025t0.004 (d

4-15-82 289 0.03310.004 10-14-82 282 0.012i0.003 4-22-82 288 0.026i0.003 10-21-82 281 0.02120.004 4-29-82 285 0.029i0.004 10-28-82 286 0.019i0.003 5-06-82 285 0.031i0.004 11-04-82 277 0.019i0.003 5-13-82 289 0.020i0.003 11-11-82 281 0.019i0.003 5-20-82 295 0.019i0.003 11-18-82 279 0.03110.004 5-27-82 288 0.012i0.003 11-25-82 232a 0.034i0.004 6-03-82 286 0.014i0.003 12-02-82 328b 0.021*0.003 6-10-82 290 0.017*0.003 12-09-82 277 0.023i0.003 l

6-17-82 290 0.017*0.003 12-16-82 288 0.027i0.003 6-24-82 291 0.015t0.003 12-22-82 251a 0.017t0.004 7-01-82 296 0.015i0.003 12-30-82 313b 0.011i0.002 2nd Qtr. mean i s.d.

0.021i0.007 4th Qtr. mean i s.d.

0.021i0.007 a Pump ran for 6 days.

Pump ran for 5 days.

17

HAZLETON CNVIRONMENTAL. SCENCE]

Table 13.

Airborne particulates collected at Location D-10, (Atkins),

analysis for gross beta.

Collection: Weekly.

Date Volume Gross Bgta Date Volgme Gross Bgta 3

3 (m )

(pC1/m3)

Collected (m )

(pCi/m)

Collected 1-07-82 288 0.052i0.004 7-08-82 285 0.017i0.003 1-14-82 285 0.044i0.004 7-15-82 284 0.022i0.003 1-21-82 284 0.05010.004 7-22-82 287 0.014i0.003 1-28-82 284 0.04410.004 7-29-82 286 0.027i0.004 2-04-82 286 0.044i0.004 8-05-82 284 0.025t0.003 2-11-82 284 0.048i0.005 8-12-82 286 0.020i0.003 2-18-82 285 0.068i0.005 8-19-82 281 0.037i0.004 2-25-82 290 0.026i0.003 8-26-82 283 0.022i0.004 3-04-82 283 0.027i0.004 9-02-82 275 0.016i0.003 3-11-82 283 0.036i0.004 9-09-82 277 0.017i0.003 3-18-82 286 0.016i0.003 9-16-82 278 0.014i0.003 3-25-82 285 0.022i0.003 9-23-82 277 0.020i0.003 4-01-82 284 0.029i0.003 9-30-82 277 0.020i0.004 1st Qtr. mean

  • s.d.

0.03910.015 3rd Qtr. mean i s.d.

0.022i0.007 4-08-82 286 0.029i0.003 10-07-82 285 0.025i0.004 4-15-82 290 0.035i0.004 10-14-82 288 0.012*0.003 4-22-82 283 0.025i0.003 10-21-82 286 0.021i0.004 4-29-82 285 0.03710.004 10-28-82 280 0.022i0.004 5-06-82 285 0.036i0.004 11-04-82 288 0.017i0.003 5-13-82 285 0.03010.004 11-11-82 287 0.022t0.003 5-20-82 286 0.026t0.003 11-18-82 285 0.032i0.004 5-27-82 285 0.012i0.003 11-25-82 245a 0.027i0.004 6-03-82 283 0.015i0.003 12-02-82 325b 0.019i0.003 6-10-82 286 0.017i0.003 12-09-82 284 0.024i0.003 6-17-82 286 0.018te.003 12-16-82 289 0.027i0.003 6-24-82 286 0.013t0.003 12-22-82 249a 0.017i0.004 7-01-82 284 0.01410.003 12-30-82 329b 0.020i0.003 2nd Qtr. mean i s.d.

0.024i0.009 4th Qtr. mean i s.d.

0.022i0.005

$Pumpranfor6 days.

Pump ran for 8 days.

O 18

HAZLETON ENVIRINMENTAL SClZNCO3 O

Table 14.

Airborne particulates collected at Location D-11, (Toddv111e),

analysis for gross beta.

Collection: Weekly.

Date Volyme Gross Beta Date Volyme Gross 8gta d

Collected (m3)

(pCi/m)

Collected (m3)

(pCi/md) 1-07-82 288 0.06210.005 7-08-82 275 0.014i0.003 1-14-82 284 0.05010.004 7-15-82 272 0.020i0.003 1-21-82 284 0.058i0.005 7-22-82 284 0.01810.003 1-28-82 284 0.044i0.004 7-29-82 287 0.02910.004 2-04-82 285 0.062i0.005 8-05-82 284 0.02610.003 2-11-82 285 0.05910.005 8-12-82 285 0.01810.003 2-18-82 286 0.068i0.005 8-19-82 286 0.034i0.004 2-25-82 288 0.023i0.003 8-26-82 288 0.027i0.004 3-04-82 285 0.021i0.003 9-02-82 283 0.017*0.003 3-11-82 283 0.03210.004 9-09-82 279 0.017i0.003 3-18-82 286 0.011i0.002 9-16-82 286 0.018i0.003 3-25-82 270 0.018i0.003 9-23-82 286 0.01410.003 4-01-82 285 0.014i0.003 9-30-82 285 0.037i0.004 1st Qtr. mean i s.d.

0.040i0.021 3rd Qtr. mean i s.d.

0.022i0.008 L (%

4-08-82 285 0.025i0.003 10-07-82 285 0.03010.004

' s#

4-15-82 285 0.029i0.003 10-14-82 285 0.021i0.003 4-22-82 288 0.020i0.003 10-21-82 285 0.040i0.004 4-29-82 282 0.029i0.004 10-28-82 285 0.052 0.005 5-06-82 288 0.025t0.003 11-04-82 287 0.040i0.004 5-13-82 277 0.02010.003 11-11-82 86 0.04510.004 5-20-82 276 0.019t0.003 11-18-82 285 0.060i0.005 5-27-82 283 0.012i0.003 11-25-82 245a 0.073i0.006 6-03-82 282 0.015i0.003 12-02-82 327b 0.053i0.004 6-10-82 286 0.01410.003 12-09-82 286 0.046i0.004 6-17-82 280 0.018i0.003 12-16-82 285 0.028i0.003 6-24-82 291 0.015i0.003 12-22-82 245a 0.020i0.004 7-01 42 280 0.016i0.003 12-30-82 327b 0.023i0.003 2nd Qtr. mean i s.d.

0.020i0.006 4th Qtr. mean i s.d.

0.041i0.016

  • Pump ran for 6 days.

Pump ran for 8 days.

O 19

HAZLETON ENVIRONM2NTAL CCCNC]O O

Table 15.

Airborne particulates collected at Location 0-12, (Iowa City),

analysis for gross beta. Collection: Weekly.

Date Volume Gross Beta Date Volume Gross Bgta 3

3 3

3 Collected (m )

(pCi/m )

Collected (m )

(pCi/m )

1-07-82 288 0.052i0.004 7-08-82 286 0.019i0.003 1-14-82 285 0.048i0.004 7-15-82 286 0.024i0.003 1-21-82 284 0.04810.004 7-22-82 287 0.016i0.003 1-28-82 284 0.038i0.004 7-29-82 287 0.031i0.004 2-04-82 286 0.042i0.004 8-05-82 284 0.02810.003 2-11-82 284 0.049i0.005 8-12-82 286 0.01810.003 2-18-82 284 0.053i0.005 8-19-82 277 0.02910.004 2-25-82 290 0.023i0.003 8-26-82 292 0.02210.004 3-04-82 283 0.024i0.003 9-02-82 288 0.012t0.002 3-11-82 283 0.036i0.004 9-09-82 285 0.017i0.003 3-18-82 286 0.013i0.003 9-16-82 281 0.011i0.003 3-25-82 285 0.017i0.003 9-23-82 287 0.01610.003 4-01-82 285 0.018i0.003 9-30-82 284 0.035i0.004 1st Qtr. mean i s.d.

0.035i0.015 3rd Qtr. mena t s.d.

0.02110.008

's 4-08-82 286 0.023i0.003 10-07-82 285 0.037i0.004 (V

4-15-82 289 0.031*0.004 10-14-82 284 0.01310.003 4-22-82 284 0.01910.003 10-21-82 287 0.02210.004 4-29-82 284 0.034t0.004 10-28-82 287 0.029i0.004 5-06-82 284 0.029i0.004 11-04-82 286 0.020i0.003 5-13-82 284 0.029i0.004 11-11-82 286 0.032i0.004 5-20-82 287 0.022i0.003 11-18-82 285 0.034i0.004 5-27-82 285 0.011*0.003 11-25-82 243a 0.026*0.004 6-03-82 284 0.015i0.003 12-02-82 329b 0.031i0.003 6-10-82 286 0.020i0.003 12-09-82 293 0.027i0.003 6-17-82 285 0.016i0.003 12-16-82 293 0.029i0.003 6-24-82 285 0.01410.003 12-22-82 250a 0.024i0.004 7-01-82 286 0.020i0.003 12-30-82 317b 0.021i0.003 2nd Qtr. mean t s.d.

0.022i0.007 4th Qtr. mean i s.d.

0.027i0.007 Pump ran for 6 days.

b Pump ran for 8 days.

O 20

HAZLETON ENVIRONMENTAL SCENCE]

Table 16.

Airborne particulates collected at Location 0-13, (Alburnett),

analysis for gross beta.

Collection: Weekly.

Date Volpe GrossBgta Date Volgme GrossBgta (m )

(pCi/m )

Collected (m3)

(pC1/m)

Collected 1-07-82 288 0.05110.004 7-08-82 286 0.020t0.003 1-14-82 284 0.046i0.004 7-15-82 285 0.02Ei0.003 1-21-82 284 0.050i0.004 7-22-82 282 0.015i0.003 1-28-82 284 0.036i0.004 7-29-82 290 0.025i0.004 2-04-82 285 0.04410.004 8-05-82 286 0.022i0.003 2-11-82 285 0.055i0.005 8-12-82 284 0.016i0.003 2-18-82 286 0.064i0.005 8-19-82 286 0.034t0.004 2-25-82 287 0.021i0.003 8-26-82 286 0.027i0.004 3-04-82 285 0.023i0.003 9-02-82 280 0.019i0.003 3-11-82 283 0.045i0.004 9-09-82 285 0.019*0.003 3-18-82 286 0.010i0.002 9-16-82 283 0.016t0.003 3-25-82 286 0.019i0.003 9-23-82 286 0.013i0.003 4-01-82 286 0.019i0.003 9-30-82 285 0.028i0.003 1st Qtr. mean i s.d.

0.037i0.017 3rd Qtr. mean i s.d.

0.021i0.006 4-08-82 285 0.028i0.003 10-07-82 286 0.028i0.004 4-15-82 285 0.041i0.004 10-14-82 285 0.010i0.003 4-22-82 288 0.020i0.003 10-21-82 285 0.018i0.003 4-29-82 282 0.03910.004 10-28-82 286 0.025i0.004 5-06-82 285 0.033i0.004 11-04-82 287 0.017i0.003 5-13-82 284 0.03010.004 11-11-82 286 0.020t0.003 5-20-82 286 0.026i0.003 11-18-82 285 0.024i0.003 5-27-82 284 0.010i0.003 11-25-82 245a 0.026t0.004 6-03-82 286 0.016i0.003 12-02-82 327b 0.026i0.003 6-10-82 285 0.020i0.003 12-09-82 286 0.019i0.003 6-17-82 284 0.018i0.003 12-16-82 285 0.027i0.003 6-24-82 286 0.016i0.003 12-22-82 245a 0.024i0.004 7-01-82 286 0.020i0.003 12-30-82 327b 0.021i0.003 l

2nd Qtr. mean i s.d.

0.024i0.009 4th Qtr. mean i s.d.

0.022i0.005 l

l 8 Pump ran for 6 days.

Pump ran for 8 days.

O 21

HAZLETON CNVIRONMENTAl. SCENC]D f

Table 17.

Airborne particulates collected at Location D-14, (Alice),

analysis for gross beta.

Collection:

Weekly.

Date Volyme Gross 8gta Date Volyme Gross Beta Colleci.ed (m3)

(pCi/m )

Collected (m3)

(pCi/m)

J J

1-07-82 284 0.051*0.004 7-08-82 205a 0.021*0.004 1-14-82 298 0.045i0.004 7-15-82 213b 0.025i0.004 1-21-82 277 0.05210.004 7-22-82 281 0.018i0.003 1-28-82 273 0.037i0.004 7-29-82 287 0.026f0.004 2-04-82 276 0.048i0.004 8-05-82 278 0.020i0.003 2-11-82 295 0.04510.004 8-12-82 278 0.014i0.003 2-18-82 272 0.032i0.004 8-19-82 276 0.032i0.004 2-25-82 273 0.02210.003 8-26-82 284 0.02?i0.004 3-04-82 285 0.025i0.003 9-02-82 271 0.018i0.003 3-11-82 283 0.029*0.003 9-09-82 299 0.015i0.003 3-18-82 286 0.012i0.002 9-16-82 290 0.014i0.003 3-25-82 286 0.01910.003 9-23-82 288 0.015t0.003 4-01-82 285 0.024i0.003 9-30-82 286 0.033i0.004 1st Qtr. mean i s.d.

0.034i0.013 3rd Qtr. mean i s.d.

0.021i0.006 4-08-82 285 0.028i0.003 10-07-82 287 0.024i0.004 4-15-82 286 0.034i0.004 10-14-82 290 0.012i0.003 s

4-22-82 288 0.024i0.003 10-21-82 288 0.015f0.003 4-29-82 282 0.029i0.004 10-28-82 282 0.014i0.003 5-06-82 281 0.031i0.004 11-04-82 285 0.017*0.003 5-13-82 290 0.021i0.003 11-11-82 285 0.025i0.003 5-20-82 295 0.022i0.003 11-18-82 285 0.027i0.003 5-27-82 292 0.012i0.003 11-25-82 244b 0.027i0.004 6-03-82 294 0.018i0.003 12-02-82 327c 0.026i0.003 6-10-82 288 0.01910.003 12-09-82 286 0.026i0.003 6-17-82 284 0.013i0.003 12-16-82 285 0.01810.003 6-24-82 289 0.016i0.003 12-22-82 245b 0.020i0.004 7-01-82 282-0.018i0.003 12-30-82 327c 0.021i0.003 2nd Qtr. mean t s.d.

0.022i0.007 4th Qtr. mean i s.d.

0.021t0.005 Electrical fuse blown.

b Pump ran for 6 days.

c Pump ran for 8 days.

22

HAZR ETON ENVIRONMENTAL SCCNC3 Table 18.

Airborne particulates collected at Location D-15, (On-site),

analysis for gross beta.

Collection: Weekly.

Date Volume GrossBgta Date Volgme GrossBgta Collected (md)

(pCi/m)

Collected (m )

(pCi/m) 1-08-82 328a 0.054i0.004 7-08-82 282 0.010io.003 1-15-82 276 0.050i0.004 7-15-82 285 0.015i0.003 1-21-82 229b 0.04610.005 7-22-82 270

<0.003d 1-28-82 275 0.035i0.004 7-29-82 288 0.02810.004 2-04-82 269 0.048i0.004 8-05-82 293 0.025i0.003 2-11-82 277 0.05210.005 8-12-82 194 0.015t0.003 2-18-82 269 0.027t0.004 8-19-82 30

<0.270 2-25-82 280 0.023i0.003 8-26-82 255 0.02010.004 3-04-82 286 0.024i0.003 9-02-82 285 0.021*0.003 3-11-82 281 0.036i0.004 9-09-82 287 0.014i0.003 3-18-82 272 0.014i0.003 9-16-82 285 0.02010.004 3-25-82 261 0.02210.003 9-23-82 286 0.014i0.003 4-01-82 275 0.019i0.003 9-30-82 285 0.037i0.004 1st Qtr. mean i s.d.

0.035i0.014 3rd Qtr. mean i s.d.

0,02010.008 4-08-82 273 0.026i0.003 10-07-82 286 0.033i0.004 l /]

4-15-82 283 0.030i0.004 10-14-82 285 0.012i0.003 V

4-22-82 7

0.214i0.092c 10-21-82 286 0.020i0.004 4-29-82 233 0.026t0.004 10-28-82 285 0.023i0.004 5-06-82 290 0.029i0.004 11-04-82 288 0.01810.003 l

5-13-82 289 0.02710.003 11-11-82 285 0.027i0.003 5-20-82 293 0.020i0.003 11-18-82 285 0.030t0.004 5-27-82 285 0.012i0.003 11-25-82 255b 0.031i0.004 6-03-82 289 0.017i0.003 12-02-82 318f 0.01710.003 6-10-82 291 0.016i0.003 12-09-82 244 0.029i0.004 6-17-82 285 0.012i0.003 12-16-82 258 0.032i0.004 6-24-82 292 0.014i0.003 12-22-82 225b 0.023t0.004 7-01-82 286 0.012i0.003 12-30-82 328f 0.020i0.003 2nd Qtr. mean i s.d.

0.02010.007 4th Qtr. mean i s.d.

0.024i0.007 l

l Pump ran for 8 days. Collection was delayed because of snow storm.

I Pump ran for 6 days.

c Result unreliable due to a very low volume caused by electrical failure and was excluded in the 2nd Qtr. mean.

d Filter paper was light because filter was torn thus letting all the air pass through.

e Low volume due to blown fuse.

f Pump ran for 8 days.

l 23

MAZl.ETON ENVIRONMENTAI. SCl~NCED

()

Table 19.

Airborne particulates collected at Location D-16, (On-site),

analysis for gross beta.

Collection: Weekly.

Date Volyme Gross Bgta Date Volyme Gross Bgta Collected (m3)

(pC1/m)

Collected (m3)

(pCi/m) 3 3

1-07-82 287 0.047i0.004 7-08-82 294 0.018i0.003 1-14-82 302 0.043i0.004 7-15-82 294 0.019i0.003 1-21-82 274 0.043i0.004 7-22-82 290 0.014i0.003 1-28-82 285 0.032i0.004-7-29-82 288 0.030i0.004 2-04-82 285 0.050i0.004 8-05-82 283 0.026i0.003 2-11-82 285 0.055i0.005 8-12-82 285 0.016i0.003 2-18-82 285 0.065i0.005 8-19-82 285 0.036i0.004 2-25-82 286 0.021i0.003 8-26-82 283 0.025i0.003 3-04-82 287 0.025*0.003 9-02-82 276 0.025i0.003 3-11-82 283 0.03910.004 9-09-82 282 0.017i0.003 3-18-82 286 0.013i0.003 9-16-82 294 0.01610.003 3-25-82 286 0.019i0.003 9-23-82 290 0.015i0.003 4-01-82 285 0.019i0.003 9-30-82 293 0.030i0.004 1st Qtr. mean i s.d.

0.03610.016 3rd Qtr. mean i s.d.

0.022i0.007 4-08-82 286 0.02710.003 10-07-82 294 0.027i0.004 C

4-15-82 284 0.030i0.004 10-14-82 290 0.0lli0.003

)

s--

4-22-82 286 0.022i0.003 10-21-82 288 0.013i0.003 4-29-82 285 0.031i0.004 10-28-82 292 0.024i0.004 5-06-82 286 0.029i0.004 11-04-82 288 0.020i0.003 5-13-82 292 0.024i0.003 11-11-82 289 0.015i0.003 5-20-82 296 0.017i0.003 11-18-82 286 0.030i0.004 5-27-82 287 0.013i0.003 11-25-82 245a 0.036i0.004 6-03-82 296 0.015i0.003 12-02-82 318b 0.019i0.003 6-10-82 296 0.016i0.003 12-09-82 277 0.026i0.003 6-17-82 291 0.01610.003 12-16-82 280 0.02910.003 6-24-82 295 0.01710.003 12-22-82 244a 0.022i0.003 7-01-82 295 0.020i0.003 12-30-82 326b 0.018i0.003 2nd Qtr. mean i s.d.

0.021i0.006 4th Qtr. mean i s.d.

0.022i0.007 Pump ran for 6 days.

b Pump ran for 8 days.

O v

24

O O

O Table 20.

Airborne particulate samples, quarterly composites of weekly samples, analysis for strontium-89, strontium-90, and gamma emitting isotopes.

3 Sample Description and Activity (pCi/m )

location Isotope 1st Q 2nd Q 3rd Q 4th Q D-1 Lab Code DAP-23 DAP-%

DAP-170 DAP-244 Volume (m3) 3695 3522 3619 3677 Sr-89

<0.0024

<0.0018

<0.0015

<0.0009 I*

Sr-90

<0.0007

<0.0011

<0.0006

<0.0006 Be-7 0.09710.026 0.11110.028

<0.056 0.10310.024 Nb-95

<0.0019

<0.0023

<0.0025

<0.0028 0

Zr-95

<0.0053

<0.0056

<0.0047

<0.0042 Z

Ru-103

<0.0053

<0.0039

<0.0047

<0.0036 m2 Ru-106

<0.017

<0.012

<0.015

<0.016 Cs-134

<0.0016

<0.0010

<0.0014

<0.0020 g

Cs-137

<0.0017

<0.0010

<0.0014

<n.0020 0

m Ce-141

<0.0092

<0.0078

<0.0073

<0.0068 Z

m l

Ce-144

<0.0098 0.02010.006

<0.0071

<0.011 D-2 Lab Code DAP-24 DAP-97 DAP-171 DAP-245 3

Volume (m )

3714 3708 3727 3710 g.

Sr-89

<0.0019

<0.0017

<0.0015

<0.0008 Sr-90

<0.0005

<0.0007

<0.0006

<0.0004 E

Z Be-7 0.13410.029 0.14310.032

<0.059 0.10810.024 m

Nb-95

<0.0039

<0.0022

<0.0022

<0.0014 m

Zr-95

<0.0053

<0.0028

<0.0028

<0.0042 Ru-103

<0.0045

<0.0043

<0.0026

<0.0036 Ru-106

<0.013

<0.019

<0.011

<0.011 Cs-134

<0.0012

<0.0014

<0.0016

<0.0009 Cs-137

<0.0017

<0.0020

<0.0011

<0.0019 Ce-141

<0.0090

<0.0067

<0.0045

<0.0074 Ce-144

<0.0095

<0.0099

<0.0081

<0.0068 l

l

O O

O Table 20.

(continued) 3 Sample Descriation and Activity (pCi/m )

Location Isotope 1st Q 2nd Q 3rd Q 4th Q D-3 Lab Code DAP-25 DAP-98 DAP-172 DAP-246 Volume (m3) 3713 3710 3711 3700 Sr-89

<0.0033

<0.0018

<0.0017

<0.0008 Sr-90

<0.0009

<0.0008 0.000710.0005-

<0.0005 g

i D

Be-7 0.12210.028 0.16310.033 0.12010.028 0.11110.026 Nb-95

<0.0031

<0.0020

<0.0016

<0.0025 g

Zr-95

<0.0050

<0.0050

<0.0040

<0.0053 0

Ru-103

<0.0037

<0.0036

<0.0062

<0.0033 Z

Ru-106

<0.017

<0.019

<0.010

<0.013 m

Cs-134

<0.0019

<0.0014

<0.0017

<0.0019 2

l Cs-137

<0.0014

<0.0023

<0.0025

<0.0014 Ce-141

<0.0096

<0.0087

<0.0051

<0.0067 3l g

Ce-144

<0.0396

<0.0084

<0.0093

<0.012 h

D-4 Lab Code DAP-26 DAP-99 DAP-173 DAP-247 3

Volume (m )

3776 3756 3711 3714 Sr-89

<0.0039

<0.0018

<0.0017

<0.0008 r

Sr-90

<0.0019

<0.0008

<0.0007

<0.0005 W

O Be-7

<0.071 0.137i0.030 0.09210.024

<0.050 l

Nb-95

<0.0037

<0.0025

<0.0022

<0.0019 n

Zr-95

<0.0042

<0.0050

<0.0040

<0.0026 m"

Ru-103

<0.0054

<0.0039

<0.0034

<0. 00.'! a 1

Ru-106

<0.015

<0.011

<0.012

<0.013 Cs-134

<0.0017

<0.0022

<0.0016

<0.0014 Cs-137

<0.0017

<0.0023

<0.0019

<0.0016 Ce-141

<0.0085

<0.0068

<0.0057

<0.0047 Ce-144

<0.0096

<0.0082

<0.0073

<0.011

p p

n V

Table 20.

(continued) 3 Sample Descr13 tion and Activity (pCi/m )

location Isotope 1st Q 2nd 1 3rd Q 4th Q D-5 Lab Code DAP-27 DAP-100 DAP-174 DAP-248 Volume (m3) 3708 3691 3502 3711 Sr-89

<0.0040

<0.0018

<0.0018

<0.0010 Sr-90

<0.0021

<0.0008

<0.0008

<0.0006 I>l Be-7 0.10710.026 0.11210.027

<0.056 0.08510.021 4

Nb-95

<0.0025

<0.0025

<0.0023

<0.0026 q

Zr-95

<0.0050

<0.0030

<0.0048

<0.0039 0

Ru-103

<0.0054

<0.0048

<0.0028

<0.0031 2

Ru-106

<0.016

<0.014

<0.022

<0.012 m

Cs-134

<0.0016

<0.0014

<0.0015

<0.0012 2

Cs-137

<0.0013

<0.0014

<0.0013

<0.0016 Ce-141

<0.0071

<0.0081

<0.0076

<J.0059 0

Ce-144

<0.0067

<0.010

<0.0079

<0.0057 Z

l D-6 Lab Code DAP-28 DAP-101 DAP-175 DAP-249 m

Volume (m3) 3826 3676 3439 3705 r

Sr-89

<0.0019

<0.0014

<0.0016

<0.0009 Sr-90

<0.0007

<0.00%

<0.0007

<0.0005 E

Be-7 0.07910.016 0.11910.029 0.11710.030

<0.048 Z

Nb-95

<0.0015

<0.0020

<0.0036

<0.0023 0

Zr-95

<0.0028

<0.003G

<0.0040

<0.0047 l

Ru-103

<0.0023

<0.0026

<0.0079

<0.0036 Ru-106

<0.011

<0.0092

<0.013

<0.0071 l

Cs-134

<0.0007

<0.0014

<0.0019

<0.0012 Cs-137

<0.0012

<0.0016

<0.0017

<0.0015 Ce-141

<0.0037

<0.0062

<0.0070

<0.0070 Ce-144

<0.0064

<0.011

<0.0071

<0.011 l

l

O O

O Table 20.

(continued) 3 Sample Descri ation and Acti rity (pCi/m )

4 Location Isotope 1st Q 2nd Q 3rd Q 4th Q D-7 Lab Code DAP-29 DAP-102 DAP-176 DAP-250 3

Volume (m )

3703 3717 3703 3712 Sr-89

<0.0018

<0.0019

<0.0017

<0.0012 Sr-90

<0.0007 0.001110.0005 0.000510.0005

<0.0006 I

Be-7

<0.073 0.13510.030

<0.062 0.09210.022 Nb-95

<0.0022

<0.0017

<0.0030

<0.0019 q

Zr-95

<0.010

<0.0047

<0.0028

<0.0030 0

Ru-103

<0.0054

<0.0053

<0.0030

<0.0026 Z

Ru-106

<0.017

<0.0090

<0.0017

<0.014 m

l Cs-134

<0.0023

<0.0007

<0.0012

<0.0011 l

Cs-137

<0.0014

<0.0014

<0.0017

<0.0014 g

Ce-141

<0.011

<0.0071

<0.0090

<0.0067 o

mm Ce-144

<0.0085

<0.0095

<0.011

<0.0092 Z

l D-8 Lab Code DAP-30 DAP-103 DAP-177 DAP-251 m

Volume (m3) 3709 3703 3744 3713 Sr-89

<0.0018

<0.0023

<0.0016

<0.0010 l

Sr-90

<0.0006

<0.0013

<0.0007

<0.0005 m

Be-7

<0.047

<0.060

<0.054 0.08410.023 Z

Nb-95

<0.0028

<0.0020

<0.0038

<0.0026 Q

Zr-95

<0.0047

<0.0062

<0.0034

<0.0059 m

Ru-103

<0.0042

<0.0048

<0.0043

<0.0053 l

Ru-106

<0.015

<0.017

<0.010

<0.0015 Cs-134

<0.0016

<0.0016

<0.0010

<0.0011 Cs-137

<0.0016

<0.0019

<0.0012

<0.0011 Ce-141

<0.010

<0.011

<0.0050

<0.0073 Ce-144

<0.0078

<0.0076

<0.0082

<0.0096

O O

O Table 20.

(continued) 3 Sample Description and Activity (pCi/m )

Location Isotope 1st Q 2nd Q 3rd Q 4th Q D-9 Lab Code DAP-31 DAP-104 DAP-178 DAP-252 Volume (m3) 3548 3757 3720 3664 Sr-89

<0.0024

<0.0028

<0.0017

<0.0010 Sr-90

<0.0009

<0.0008

<0.0006

<0.0006 g

Be-7 0.11420.028 0.122i0.031 0.10310.026 0.07610.019 Nb-95

<0.0030

<0.0026

<0.0020

<0.0012 Zr-95

<0.0037

<0.0047

<0.0036

<0.0034 4l Ru-103

<0.0043

<0.0042

<0.0036

<0.0026 Ru-106

<0.011

<0.014

<0.015

<0.0084 Cs-134

<0.0015

<0.0014

<0.0019

<0.0017 z

Cs.'.37 10.0017

<0.0017

<0.0013

<0.0012 Ce-141

<0.010

<0.0057

<0.0063

'0.0042 3j Ce-144

<0.0079

<0.0084

<0.0071

<0.0076 h

D-10 Lab Code DAP-32 DAP-105 DAP-179 DAP-253 3

Volume (m )

3707 3710 3660 3770 Sr-89

<0.0027

<0.0023

<0.0020

<0.0011 r-Sr-90

<0.0010 0.000610.0004

<0.0008

<0.0005 m

G

!5

' *Mi

'eM EMi' lUM0 i

Zr-95

<0.0036

<0.0059

<0.0030

<0.0045 m

Ru-103

<0.0042

<0.0051

<0.0030

<0.0034 8

Ru-106

<0.019

<0.016

<0.017

<0.013 Cs-134

<0.0019

<0.0007

<0.0014

<0.0017 Cs-137

<0.0022

<0.0025

<0.0013

<0.0011 Ce-141

<0.0088

<0.0081

<0.0065

<0.0076 Ce-144

<0.012

<0.0067

<0.012

<0.0070

O O

O Table 20.

(continued) 3 Sample Description and Activity (pCi/m )

location Isotope 1st Q 2nd Q 3rd Q 4th Q D-11 Lab Code DAP-33 DAP-106 DAP-180 DAP-254 3

Volume (m )

3693 3683 3680 3713 Sr-89

<0.0021

<0.0023

<0.0020

<0.0013 Sr-90

<0.0013 0.000710.0004

<0.0008

<0.0006 g

Be-7 0.09910.026

<0.020

<0.048 0.09910.022 Nb-95

<0.0031

<0.0020

<0.0028

<0.0023 Zr-95

<0.0051

<0.0037

<0.0036

<0.0026 l

Ru-103

<0.00'8

<0.0036

<0.0036

<0.0048 Ru-106

<0.01c

<0.016

<0.012

<0.010 m

Cs-134

<0.0016

<0.0017

<0.0014

<0.0013 z

Cs-137

<0.0020

<0.0011

<0.0011

<0.0011 Ce-141

<0.0057

<0.0059

<0.0053

<0.0048 3

g Ce-144

<0.0076

<0.0073

<0.011

<0.0061 l

h D-12 Lab Code DAP-34 DAP-107 DAP-181 DAP-255 3

l Volume (m )

3707 3709 3710 3725 Sr-89

<0.0044

<0.0023

<0.0018

<0.0012 r

Sr-90

<0.0023

<0.0008

<0.0007

<0.0006 e

i 9

Be-7 0.125i0.028 0.11910.031 0.10810.027 0.09110.029 m

h Nb-95

<0.0030

<0.0031

<0.0023

<0.0054 Zr-95

<0.0050

<0.0051

<0.0030

<0.0060 m

Ru-103

<0.0071

<0.0043

<0.0047

<0.0057 8

Ru-106

<0.012

<0.0022

<0.017

<0.022 Cs-134

<0.0015

<0.0012

<0.0010

<0.0026 Cs-137

<0.0012

<0.0022

<0.0008

<0.0023 Ce-141

<0.0082

<0.0087

<0.0057

<0.0028 Ce-144

<0.0078

<0.0096

<0.0087

<0.012

O O

O Table 20.

(continued) 3 Sample Description and Activity (pCi/m )

Location Isotope 1st Q 2nd Q 3rd Q 4th Q D-13 Lab Code DAP-35 DAP-108 DAP-182 DAP-256 3

Volume (m )

3709 3707 3704 3714 Sr-89

<0.0021

<0.0027

<0.0016

<0.0010 Sr-90 0.0005i0.0003

<0.0009

<0.0007

<0.0005 x

Be-7 0.11810.030 0.16410.036

<0.062 0.05110.035 Nb-95

<0.0031

<0.0020

<0.0025

<0.0082 Zr-95

<0.0062

<0.0042

<0.0030

<0.0050 0

Ru-103

<0.0045

<0.0071

<0.0040

<0.0067 Z

Ru-106

<0.014

<0.011

<0.010

<0.023 m

Cs-134

<0.0014

<0.0020

<0.0012

<0.0028 Z

Cs-137

<0.0023

<0.0015

<0.0011

<0.0025 5

Ce-141

<0.0056

<0.0061

<0.0065

<0.0028 3l Ce-144

<0.0065

<0.0073 0.021i0.007

<0.012 r

D-14 Lab Code DAP-36 DAP-109 DAP-183 DAP-257 m

3 Volume (m )

3673 3736 3536 3716 Sr-89

<0.0024

<0.0024

<0.0021

<0.0010 r-Sr-90

<0.0006

<0.0007

<0.0013

<0.0006 Be-7 0.11710.026 0.15110.032

<0.060 0.08310.020 Nb-95

<0.0033

<0.0017

<0.0025

<0.0028 0

Zr-95

<0.0067

<0.0022

<0.0043

<0.0034 l

l Ru-103

<0.0040

<0.0045

<0.0062

<0.0025 l

Ru-106

<0.011

<0.012

<0.015

<0.012 Cs-134

<0.0019

<0.0019

<0.0019

<0.0015 Cs-137

<0.0019

<0.0011

<0.0016

<0.0013 Ce-141

<0.0071

<0.0062

<0.0093

<0.0073 Ce-144

<0.010

<0.0074

<0.0073

<0.0067

O O

O Table 20.

(continued) 3 Sample Descri ation and Activ Hy (pC1/m )

Location Isotope 1st Q 2nd Q 3rd Q 4th Q D-15 Lab Code _

DAP-37 DAP-110 DAP-184 DAP-258 Volume (m3) 3578 3396 3298 3627 Sr-89

<0.0020

<0.0051

<0.0018

<0.0010 Sr-90

<0.0005

<0.0015

<0.0007

<0.0005 g

Be-7

<0.057 0.10610.029 0.106i0.028

<0.051 Nb-95

<0.0023

<0.0020

<0.0022

<0.0025 g

Zr-95

<0.0053

<0.0037

<0.0047

<0.0045 Ru-103

<0.0028

<0.0051

<0.0057 so.0051 ~

0 Z

Ru-106

<0.016

<0.012

<0.012

<0.016 m

Cs-134

<0.0014

<0.0012.

<0.0011

<0.0017 2

Cs-137

<0.0023

<0.%20

<0.0011

<0.0022 S

Ce-141 0.01310.004

<0.i ?. 32

<0.0074

<0.0062 3l M

Ce-144

<0.0099

<0.0071

<0.012

<0.011 D-16 Lab Code DAP-38 DAP-111 DAP-185 DAP-259 3

Volume (m )

3716 3775 3737 3713 Sr-89

<0.0024

<0.0028

<0.0018

<0.0010 r-i Sr-90

<0.0006

<0.0010

<0.0008

<0.0005 D

Be-7 0.10910.027 0.10710.027 0.09810.026 0.08910.023 l

Nb-95

<0.0023

<0.0033

<0.0020

<0.011 O

Zr-95

<0.0030

<0.0051

<0.0036

<0.019 m8 Ru-103

<0.0050

<0.0040

<0.0026

<0.0045 Ru-106

<0.022

<0.010

<0.020

<0.051 Cs-134

<0.0016

<0.0014

<0.0007

<0.0064 Cs-137

<0.0013

<0.0015

<0.0010 0.02910.004 Ce-141

<0.0093

<0.0057

<0.0050

<0.0053 Ce-144

<0.0070

<0.0076

<0.0090

<0.0062

MA2LETON ENVIRONMENTAL SCENCEJ

(' T Table 21.

Charcoal samples, weekly composites from indicator locations D-4, D-5, D-7, D-11, and D-15; analysis for iodine-131.

Collection: Weekly.

Date Volyme I-131 Activity Date Volyme I-131 Activity 3

3 Collected (m3)

(pC1/m )

Collected (m3)

(pCi/m )

1-07-82a 1496

<0.007 9-09-82 1424

<0.006 1-14-82b 1465

<0.006 9-16-82 1426

<0.006 1-21-82 1334

<0.006 9-23-82 1430

<0.006 1-28-82 1428

<0.006 9-30-82 1425

<0.006 2-04-82 1429

<0.006 10-07-82 1426

<0.006 2-11-82 1416

<0.006 10-14-82 1425

<0.006 2-18-82 1413

<0.006 10-21-82 1427

<0.006

' 25-82 1447

<0.008 10-28-82 1426

<0.006

.-04-82 1405

<0.006 11-04-82 1436

<0.006 3-11-82 1433

<0.006 11-11-82 1427

<0.006 3-18-82 1416

<0.006 11-18-82 1425

<0.006 3-25-82 1380

<0.006 11-25-82 1265

<0.006 4-01-82 1416

<0.006 12-02-82 1625

<0.006 4-08-82 1414

<0.006 12-09-82 1388

<0.006 4-15-82 1423

<0.007 12-16-82 1398

<0.0:e 4-22-82 1210

<0.006 12-22-82 1205

<0.006

~

4-29-82 1363

<0.006 12-30-82 1635

<0.006

(,')

5-06-82 1433

<0.006 5-13-82 1418

<0.006 5-20-82 1430

<0.006 5-27-82 1417

<0.006 6-03-82 1428

<0.006 6-10-82 1443

<0.006 6-17-82 1423

<0.006 1

6-24-82 1446

<0.006 l

7-01-82 1444

<0.006 7-08-82 1411

<0.006 l

7-15-82 1418

<0.006 7-22-82 1232

<0.006 7-29-82 1437

<0.006 8-05-82 1430 (0.006 8-12-82 1434

<0.006 8-19-82 1144

<0.006 8-26-82 1404

<0.006 9-02-82 1379

<0.006 l

b Sample at Location D-15 was collected on 1-08-82 Samples at location D-15 and D-5 were collected 1-15-82.

O 33

MAzLaTON ENVIRONMaNTAL SCCNCD

/^

(,)

Table 22.

Charcoal samples, weekly composites from control locations D-8, D-12, and 0-14; analysis for iodine-131. Collection: Weekly.

Date Volyme I-131 Activity Date Vol I-131 Activity Collected (m3)

(pC1/m)

Collected (m )

(pCi/M) 3 1-07-82 861

<0.01 9-09-82 870

<0.01 1-14-82 867

<0.01 9-16-82 862

<0.01 1-21-82 845

<0.01 9-23-82 860

<0.01 1-28-82 842

<0.01 9-30-82 860

<0.01 2-04-82 845

<0.01 10-07-82 862

<0.01 2-11-82 846

<0.01 10-14-82 855

<0.01 2-18-82 841

<0.01 10-21-82 860

<0.01 2-25-82 849

<0.01 10-28-82 854

<0.01 3-04-82 845

<0.01 11-04-82 858

<0.01 3-11-82 849

<0.01 11-11-82 856

<0.01 3-18-82 858

<0.01 11-18-82 855

<0.01 3-25-82 857

<0.01 11-25-82 732

<0.01 4-01-82 856

<0.01 12-02-82 983

<0.01 4-08-82 856

<0.01 12-09-82 865

<0.01 4-15-82 860

<0.01 12-16-82 863

<0.01 4-22-82 875

<0.01 12-22-82 740

<0.01 4-29-82 862

<0.01 12-30-82 971

<0.01 x

3-06-82 832

<0.01 s

5-13-82 858

<0.01 5-20-82 868

<0.01 5-27-82 861

<0.01 6-03-82 864

<0.01 6-10-82 859

<0.01 6-17-82 855

<0.01 6-24-82 859

<0.01 7-01-82 854

<0.01 7-08-82 777

<0.01 7-15-82 784

<0.01 7-22-82 854

<0.01 7-29-82 861

<0.01 8-05-82 846

<0.01 8-12-82 849

<0.01 8-19-82 845

<0.01 8-26-82 880

<3.01 9-02-82 842

<0.01 0

35

O O

O Table 23.

Ambient gamma radiation (TLD), monthly exposure.

Location Location mR/30 days No.

Descr.

January February March Kiiril M3y June 0-1 Cedar Rapids 2.910.6 3.210.5 3.710.6 NDa 3.110.3 3.610.5 D-2 Marion 2.910.7 3.110.4 3.310.3 3.510.2 3.310.2 3.610,3 0-3 Hiawatha 4.110.8 3.210.4 3.510.4 3.510.2 3.310.4 3.710.2 y

D-4 Johnson 3.610.7 2.610.5 3.810.2 3.210.2 3.510.2 3.610.5 D-6 Center Point 3.210.8 3.110.5 3.110.4 3.410.2 3.610.3 3.410.3 0

Z D-7 Shellsberg 2.510.6 3.010.4 3.710.4 3.719.2 3.810.2 4.010.4 2

D-8 Urbana 3.510.6 3.310.6 3.510.4 3.810.3 3.910.2 3.910.6 53l D-9 Route W26 4.910.6 3.410.4 3.910.4 3. 9.+ 0. 5 4.810.5 4.410.5 I

D-10 Atkins 2.710.8 3.210.5 3.510.3 3.810.2 3.810.1 4.210.4 m

D-11 Toddville 2.610.6 3.210.6 4.210.5 4.010.2 4.410.4 4.110.4 r-D-12 Univ. of Iowa 2.7t0.5 3.410.6 3.410.4 3.310.3 3.910.6 3.810.6 m

0" D-13 Albrunett 3.410.7 2.410.6 2.910.5 NDa NDa 4.210.3 b

D-14 Alice 6.010.8 3.110.7 3.910.4 4.210.3 4.310.5 4.510.5 g

D-15 On-Site 3.710.9 3.1i0.7 3.610.4 4.610.3 4.910.5 5.210.6 D-16 On-Site 3.010.5 3.410.5 3.710.4 NDa 3.910.4 3.710.3 l

Mean i s.d.

3.Sil.0 3.110.3 3.610.3 3.710.4 3.910.5 4.010.5 l

t l

l

O O

O Table 23.

(continued) mR/30 days Location July August September October November December D-1 3.810.4 3.410.4 3.310.3 4.010.3 3.410.3 3.610.4 0-2 3.510.4 3.510.5 3.510.4 4.210.4 3.410.3 3.910.7 D-3 3.410.2 3.410.4 3.610.4 3.810.3 3.410.3 3.610.2 g

D-4 3.7 0.2 3.510.8 3.810.2 3.810.4 3.410.2 3.6i0.5 D-6 3.810.3 5.li0.6 3.510.3 3.810.2 3.510.3 3.710.3 Z

0-7 4.010.4 3.910.6 3.710.2 4.510.4 NDa 3.810.5 m

Z D-8 4.010.3 4.510.5 3.810.4 4.410.4 3.710.3 4.210.6 53l D-9 3.910.2 3.610.3 4.210.3 4.710.6 4.210.5 4.510.7 h

D-10 4.110.3' 4.110.6 3.910.4 4.010.4 3.810.5 3.810.3 D-11 3.810.3 4.510.7 3.610.3 3.910.2 3.810.5 3.710.3 t~

D-12 3.710.4 3.610.4 3.610.5 3.610.2 3.0i0.3 3.410.2 W

D D-13 3.910.3 3.410.4 4.0i0.5 4.410.4 3.810.2 4.210.4 ln 0-14 3.910.2 4.510.8 4,.210.3 5.110.4 3.810.4 4.010.4 g

0-15 5.410.7 5.310.6 4.910.5 4.810.2 4.410.2 5.010.4 D-16 4.010.4 3.3t0.3 3.710.3 4.610.5 4.010.5 4.510.4 Mean i s.d.

3.910.4 4.410.7 3.810.4 4.210.4 3.710.4 4.010.4 w.,

e

Table 23..

(continued)

Location Location aft /30 days No.

Descr.

January-February HarcF fpril May June D-17 v.5 mi N 3.716.7 3.010.5 3.010.2 4.010.3 4.210.2 4.216.3 D-18 0.5 mi NNE 3.210.5 3.510.5 3.210.2 3.810.3 4.110.5 3.710.5 D-19 0.5 mi NE 3.010.5 3.110.7 3.810.6 3.810.4 4.310.4 4.210.3 h

D-20 0.5 mi ENE 3.510.6 3.310.4 4.210.6 3.810.3 3.710.1 3.810.4 4

.h D-21 0.5 mi E 3.11017 3.510.6 3.610.3 3.710.3 4.010.6 3.810.3 a

0-22 0.5 mi ESE 3.4i0.6 2.810.6 4.210.7 NDa 3.6i0.4 3.810.5 Z

S D-23 0.5 mi SE 3.710.6 2.610.6 3.410.5 4.010.3 4.010.3 3.710.3 g

Z D-24 0.5 mi SSE 2.710.8 3.011.1 3.310.2 3.810.3 3.910.5 4.010.4 ga D-25 0.5 mi S NDa 2.810.6 3.410.3 NDA 3.610.3 3.910 5 D-26 0.5 mi SSW NDa 3.0i0.5 3.310.4 3.910.2 4.210.3 4.410.4 r-e D-27 0.5 mi SW 3.110.6 3.110.6 3.910.4 4.010.2 4.410.5 4.010.5 9ml D-28 0.5 mi WSW 2.810.8 2.5 0.5 3.310.4 4.310.4 4.810.7 4.810.5 m8 D-29 0.5 mi W 2.810.6 2.410.4 3.810.5 4.410.4 4.310.4 5.0i0.4 D-30 0.5 mi WNW 4.110.5 2.810.7 NDa 4.7i3.4 4.610.4 4.610.2 D-31 0.5 mi NW NDa 3.210.5 3.810.2 4.910.?

4.910.5 5.710.6 D-32 0.5 mi NNW 4.lil.0 3.110.5 3.910.3 5.110.3 5.510.5 4.610.4 Mean i.s.d.

3.310.5 3.010.3 3.610.4 4.210.5 4.310.5 4.310.6 l

l I

O O

O Table 23.

(cant rued) mR/30 days Location July August September October November December D-17 4.510.7 3.610.4 4.0i0.5 4.810.5 3.810.2 4.110.3 D-18 3.810.5 3.710.7 3.810.4 4.li0.3 3.710.2 4.0i0.6 D-19 3.6i0.2 3.F50.5 3.910.4 4.6i0.4 4.210.5 4.110.3 D-20 3.710.4 4.110.7 3.810.3 4.410.4 4.310.7 4.910.6 D-21 3.910.4 3.910.4 4.Di0.6 4.110.3 NDa 4.410.3 D-22 3.410.3 3.710.7 3.510.3 4.010.2 3.510.2 4.110.3 D-23 3.510.2 3.810.9 3.610.2 4.410.4 3.610.3 4.510.5 N$

D-24 4.010.6 4.010.5 4.0i0.8 4.310.4 3.810.3 4.310.4 D-25 3.6i0.3 4.111.0 3.910.4 4.610.7 4.110.9 4.310.5 D-26 4.010.2 3.610.7 3.810.4 4.510.6 4.210.3 4.210.5 D-27 4.210s3 3.710.4 4.2i0.4 4.410.3 4.210.6 4.410.4 D-28 4.510.3 4.010.5 4.810.7 5.210.6 4.510.7 4.610.3 D-29 4.710.4 4.010.3 4.110.2 5.110.5 4.810.4 4.810.3 D-30 4.410.2 4.310.5 4.310.2 5.610.5 4.610.2 5.0i0.4 D-31 5.310.5 4.810.4 4.710.2 d.810.8 5.210.5 5.6i0.7 D-32 4.210.2 4.510.5 4.710.4 5.310.3 4.610.5 4.7i0.4 Mean i s.d.

4.110.5 4.010.4 4.110.4 4.7i0.5 4.2i0.5 4.510.4

O O

O Table 23.

(continued)

Location Location nR/30 days No.

Descr.

January February March April May June D-33 3.0 mi N 2.710.7 2.810.6 3.010.2 3.910.3 4.210.3 4.110.4 0-34 3.0 mi NE NDa 2.710.6 3.310.6 4.110.3 4.110.3 4.410.4 D-35 3.0 mi NE 3.010.6 2.810.4 3.510.4 3.410.2 4.210.6 3.510.4 D-36 3.0 mi NE 3.110.8 3.011.1 NDa 4.010.3 4.6i0.3 4.110.5 D-37 3.0 mi E 4.810.8 3.910.6 4.010.5 4.6i0.4 5.310.7 5.010.4 z"

D-38 3.0 mi SE' 3.410.6 3.010.7 2.910.2 4.210.2 4.310.4 4.210.4 2

S D-39 3.0 mi SE 3.310.7 2.910.6 3.210.4 4.510.4 4.410.5 4.410.4 3

0-40 3.0 mi SE 3.410.5 3.310.6 3.410.4 3.910.5 4.110.3 4.210.5 D-41 3.0 mi S 3.910.7 2.810.6 3.810.6 4.010.3 4.010.3 4.510.5 0-42 3.0 mi SW 3.510.6 3.010.8 3.4i0.2 NDa 4.110.4 4.210.;

r al D-43 3.0 mi SW 3.810.6 2.810.6 4.310.5 4.010.3 3.710.4 4.110.5 h.

D-44 1.0 mi SW 3.310.5 3.110.5 4.310.4 4.710.3 5.210.4 5.810.5 D-45 1.0 mi SW 4.911.1 3.110.4 3.110.4 4.5i0.3 5.510.8 4.410.4 D-46 1.0 mi W 3.710.7 3.310.4 4.610.7 4.610.3 5.310.4 4.810.3 D-47 1.0 mi NW 4.0f0.9 3.110.6 4.710.5 4.510.3 4.810.4 5.010.6 D-48 1.0 mi NW 3.li0.7 2.810.5 3.910.4 4.510.4 5.110.2 5.010.4 Mean i s.d.

3.610.6 3.010.3 3.7i0.6 4.210.4 4.710.6 4.510.5

O O

O Table 23.

(continued) mR/30 days Location July August September October November December D-33 3.910.4 3.710.3 4.110.4 4.510.3 4.710.6 4.410.7 D-34 3.710.3 3.410.4 3.910.3 4.510.6 4.310.3 5.010.5 0-35 3.610.3 3.110.2 3.510.2 4.210.2 3.6i0.3 4.310.6 g

D-36 4.510.5 3.510.6 4.310.4 5.110.7 4.4 0.4 4.610.3 D-37 4.510.3 4.110.3 4.910.4 5.0i0.4 4.610.6 4.8i0.3 Z

D-38 4.010.3 4.0i0.4 4.110.4 4.6i0.6 4.010.3 4.7i0.4 mZ D-39 4.2i0.2 3.810.6 4.310.3 4.710.5 3.810.3 4.810.4 S3l D-40 3.910.1 3.610.7 4.410.6 4.510.3 4.310.6 4.210.3 h

D-41 4.210.3 3.810.6 4.310.3 4.710.9 3.910.3 4.310.3 D-42 3.510.2 4.710.7 3.710.5 4.110.5 3.7i0.2 4.010.6 r-D-43 4.0r0.3 3.510.6 3.610.5 3.910.6 3.910.4 3.810.3 m

0 D-44 4.910.7 4.310.7 5.110.4 5.410.9 4.610.5 4.710.2 lO D-45 4.310.3 4.410.6 4.910.3 5.110.6 NDa 4.910.3 l

i D-46 4.810.4 4.610.6 4.510.3 5.510.5 4.710.2 5.110.5 D-47 4.810.2 4.210.6 4.710.3 5.510.7 4.710.4 5.310.2 0-48 4.910.2 4.410.3 4.710.5 5.510.4 4.410.3 5.010.5 l

Mean i s.d.

4.210.5 3.910.5 4.310.5 4.810.5 4.210.4 4.610.4 l

l

O O

O Table 23.

(continued)

Location Location mR/30 days No.

Descr.

January February March April May June D-76 0.5 mi NE NDa 3.110.5 3.510.5 4.210.3 4.410.4 4.610.3 0-77 0.5 mi NE 3.li0.6 3.310.6 3.410.3 3.610.2 3.710.2 4.010.5 D-78 0.5 mi NE 3.310.5 3.710.5 3.810.4 3.810.2 4.310.6 3.810.4 j

D-79 0.5 mi E 4.210.6 3.310.5 3.910.6 3.8 0.3 4.110.4 4.310.3 D-80 0.5 mi SE 2.610.6 3.010.4 3.410.4 3.610.4 3.610.4 3.910.3 O

D-81 0.5 rai SE 3.510.8 3.lil.0 3.410.7 3.510.3 3.510.2 3.410.2 m

D-82 0.5 mi SE 3.711.2 2.410.5 3.210.4 3.310.3 3.410.3 3.110.3 5

3 0

D-83 0.5 mi S NDa 2.910.5 3.910.6 3.710.2 3.810.4 4.010.6 Z

E" D-84 0.5 mi SW 3.7i0.8 2.610.4 3.310.4 3.7i0.3 4.210.3 3.810.5 i

D-85 0.5 mi SW 3.410.5 3.010.5 3.410.3 3.910.5 4.310.7 3.810.4 r-D-86 0.5 ni SW 3.610.6 3.410.6 3.810.4 NDa 4.710.5 4.410.5 E

D-87 0.5 mi SW 3.310.8 2.610.4 3.510.8 4.610.3 5.410.3 4.7i0.5 2

m D-88 0.5 mi W NDa 3.410.5 4.410.7 4.710.5 4.610.3 5.010.7 N

D-89 0.5 mi W 3.810.5 3.210.6 3.910.3 5.210.5 4.810.3 5.320.3 D-90 0.5 mi NW 4.510.8 3.710.7 4.210.5 4.610.2 5.410.5 5.510.6 D-91 0.5 mi N 4.010.8 3.4i0.7 3.810.3 4.610.5 4.710.6 4.510.8 l

Mean i s.d.

3.610.5 3.110.4 3.710.3 4.110.6 4.310.6 4.310.7

O O

f V

V

(

Table 23.

(continued) mrem /30 days Location July August September October November December D-76 4.310.4 4.110.6 4.410.4 5.310.8 4.310.5 4.310.3 0-77 3.710.5 3.510.3 3.910.3 4.210.4 3.910.2 3.7i0.2 D-78 3.910.3 3.810.3 4.210.3 5.010.4 4.010.3 5.211.0 I*

D-79 4.010.6 3.910.6 4.110.2 4.210.4 3.910.2 4.210.4 D-80 3.610.2 3.310.3 3.610.5 4.110.3 3.510.2 4.010.3

-eO D-81 3.410.2 3.010.4 3.510.3 4.310.4 3.910.5 4.110.3 2

4 m2 D-82 3.610.4 3.4i0.5 3.5i0.5 3.810.3 3.510.3 3.510.2 s

g D-83 3.810.3 3.410.5 4.210.5 4.110.1 NDa 4.110.4 0

Zl D-84 3.910.3 3.410.7 4.010.2 4.410.3 4.210.3 4 /510.5 f

D-85 3.910.4 2.910.3 3.810.3 4.710.5 3.910.4 3.810.3 h

D-86 4.010.3 3.310.4 4.210.4 4.910.4 4.210.3 4.110.4 n

D-87 4.6i0.4 4.010.4 4.210.2 4.7i0.2 4.410.4 4.710.4 E

Z D-88 4.510.5 4.410.5 4.310.3 4.710.3 4.510.5 4.910.6 m.

D-89

.5.110.5 5.110.6 5.010.5 5.510.5 4.810.5 5.110.4 D-90 4.610.3 4.517).3 5.110.6 5.710.4 5.310.3 5.li0.8 D-91 4.410.4 4.2i0.0 4.7i0.6 4.910.7 4.li0.5 5.110.5 Mean i s.d.

4.110.5 3.810.6 4.210.5 4.710.5 4.2i0.5 4.410.6 a ND = No data. TLDs lost in the field.

HAZ1.ETON C NVIRONMENTAR. CCCNC33 Table 24.

Anbient gamma radiation (TLD), annui.1 exposure.

Normalized Normalized Location mR/365 days to 30 days Location nR/365 days to 30 days D-1 40.5i4.6 3.3i0.4 D-33 44.2i3.4 3.6t0.3 D-2 43.9i3.1 3.6i0.3 D-34 47.0i3.8 3.9t0.3 D-3 42.lil.5 3.5t0.1 D-35 48.8i4.3 4.0i0.4 D-4 41.li4.0 3.4i0.3 D-36 48.0i5.5 3.9i0.5 D-6 45.li5.0 3.7i0.4 D-37 60.8i4.3 5.0i0.4 D-7 45.5*3.2 3.7i0.3 D-38 LOST IN THE FIELD D-8.

51.li2.3 4.2*0.2 D-39 53.2t5.2 4.4i0.4 D-9 55.3i3.2 4.5i0.3 D-40 47.lt5.2 3.910.4 0-10 49.1*7.0 4.0i0.6 D-41 LOST IN THE FILED D-ll 50.2i3.5 4.li0.3 D-42 48.2i2.9 4.0iO.2 0-12 41.9i5.0 3.4i0.4 D-43 46.li2.5 3.8i0.2 D-13 60.Si3.7 5.0i0.3 D-44 62.4i5.4 5.li0.4 D-14 55.3tl.7 4.Si0.1 D-45 LOST IN THE FIELD D-15 59.6*5.1 4.9*0.4 D-46 61.2i5.8 5.0i0.5 0-16 48.9i6.3 4.0i0.5 D-47 53.Si4.0 4.4t0.3 0-48 66.2*2.3 5.4i0.2 i (v, Mean i s.d 48.7t6.ti 4.0i0.5 Mean i s.d 52.8i7.4 4.3i0.6 D-17 50.0i4.4 4.li0.4 D-76 51.3i7.2 4.2i0.6 D-18 49.2i3.1 4.0i0.3 D-77 47.2i3.4 3.9i0.3 D-19 43.2i2.5 3.5i0.2 D-78 53.li5.0 4.4i0.4 D-20 49.8i4.3 4.110.4 0-79 48.2i2.7 4.010.2 D-21 45.li4.6 3.710.4 0-80 47.3i2.7 3.910.2 D-22 45.2i4.4

. 7i0.4 D-81 43.414.3 3.6i0.4 l

D-23 45.7i4.1 3.7i0.3 0-82 40.6i4.2 3.3i0.3 l

D-24 46.li3.7 3.8i0.3 0-83 49.9i2.7 4.li0.2 0-25 50.214.3 4.110.4 D-84 52.4t4.9 4.3i0.4 D-26 47.Si3.0 3.910.3 D-85 50.7i3.7 4.210.3 0-27 50.2i3.2 4.li0.3 0-86 52.5tl.9 4.3i0.2 0-28 53.113.8 4.4i0.3 0-87 49.4i2.0 4.110.2 0-29 55.6i4.6 4.6i0.4 D-88 56.lt3.6 4.6i0.3 D-30 61.0i6.1 5.0i0.5 D-89 60.6i5.4 5.0i0.4 D-31 63.3i3.1 5.2i0.3 D-90 60.816.6 5.0t0.5 l

D-32 56.0i3.9 4.6i0.3 D-91 56.9i5.2 4.610.4 l

Mean i s.d.

50.7i5.8 4.2i0.5 Mean i s.d 51.3i5.6 4.210.5 O

43

~

HAZLETON GNVIRONMENTAL CCCNCED Db Table 25.

Milk samples collected during the non-grazing season, analysis l

for Iodine-131.

Collection: Monthly, October through April.

Location and Lab Activity (pCi/1)

Date Collected Code I-131 Indicator a

Composite 1-06-82 DMI-32

<0.4 2-02-82 78

<0.4 3-02-82 131

<0.4 4-06-82 195

<0.4 10-05-82 1165

<0.4 11-02-82 1291

<0.4 12-07-82 1358

<0.4 Control b

Composite i

1-06-82 DMI-33

<0.4 2-02-82 79

<0.4 3-02-82 132

<0.4 4-06-82 196

<0.4 10-05-82 1166

<0.4 11-02-82 1292

<0.4 12-07-82 1359

<0.4 acomposite of samples from locations D-63, D 72, D-93, D-94, D-96, b -101, and D-106.

D Composite of samples from locations 0-102 and D-105.

O 44

Hart ETON ENVIRONMENTAL. SCCNCE3 O

Table 26.

Milk samples collected during the grazing season, analysis for iodine-131 and gamma-emitting isotopes.

Collection: Weekly, May through September.

i Location and Lab Activity (pCi/1)

Date Collected Code K-40 I-131 Cs-137 Ba-La-140a

]

\\

D-63

!i 64-82 DMI-245 1230i180

<0.4

<15

<15 5-11-82 282 1250i130

<0.4

<l5

<15 5-18-82 321 1230il70

<0.4

<l5

<15 5-25-82 352 1100i200

<0.4

<15

<23 6-01-82 409,10 1190i30

<0.4

<l5

<15 6-08-82 453 1380i210

<0.4

<15

<15 6-15-82 491 1390il50

<0.4

<l5

<l5 6-22-82 523 1330i140

<0.4

<15

<15 6-29-82 562 1060t170

<0.4

<15

<15 7-06-82 610 1050i190

<0.4

<15

<20 7-13-82 646 1300i220

<0.4

<15

<19 7-20-82 695 1180t180

<0.4

<15

<15 7-27-82 726 1340i140

<0.4

<15

<15 8-03-82 785 1680il20

<0.4

<15

<15 8-10-82 820 1400t160

<0.4

<15

<15 8-17-82 855,6 1330il10

<0.4

<15

<l5 O

8-24-82 892,3 1530i60

<0.4

<15

<15 8-31-82 934 1470i210

<0.4

<15

<20 9-08-82 976 1510il10

<0.4

<15

<15 9-14-82 1016 1470i90

<0.4

<15

<15 9-21-82 1064 1400i100

<0.4

<l5

<15 9-28-82 1102 1330i190

<0.4

<15

<17 Annual mean i s.d.

1330t160

<0.4

<15

<23 I

O l

45 l

l~-

HAZLETON ENVIFIONMENTAL SCENCEJ Table 26.

(continued)

Location and Lab Activity (pCi/l)

Date Collected Code K-40 I-131 Cs-137 Ba-La-140a D-93 R 4-82 DMI-246 1590il50

<0.4

<15

<15 5-11-82 283 1390i140

<0.4

<15

<l5 5-18-82 322 1660i200

<0.4

<15

<15 5-25-82 353 1530il70

<0.4

<15

<15 6-01-82 411 1630i160

<0.4

<15

<20 6-08-82 454 1510i220

<0.4

<l5

<15 6-15-82 492 1510t210

<0.4

<15

<15 6-22-82 524 1620il50

<0.4

<15

<15 6-29-82 563 810t80

<0.4

<15

<15 7-06-32 611 1690t150

<0.4

<15

<15 7-13-82 647,8 1710i110

<0.4

<15

<15 7-20-82 696,7 1670il10

<0.4

<15

<15 7-27-82 727 1990il20

<0.4

<15

<15 8-03-82 786 2020t120

<0.4

<15

<17 8-10-82 821 2120i70

<0.4

<l5

<l5 8-17-82 857 1460i220

<0.4

<15

<22 8-24-82 894 1820t60

<0.4

<l5

<15 8-31-82 935 1900il10

<0.4

<l5

<15 9-07-82 977,8 1940i160

<0.4

<15

<15 l

9-14-82 1017 1970i70

<0.4

<15

<l5

' {3

}

9-21-82 1065 1970il20

<0.4

<l5

<15 9-28-82 1103 2040t250

<0.4

<15

<15 Annual mean i s.d.

1710i290

<0.4

<l5

<20 l

~

O 9

l 46 l

Hays ePTON ENVIRONMENTAL Scl~_~NCE3 Table 26.

(continued)

Location and Lab Activity (pCi/1)

Date Collected Code K-40 1-131 US-13/

Ba-La-140a D-94 T 54-82 DMI-247 1270 190

<0.4

<15

<15 5-11-82 284 1330*150

<0.4

<1E

<15 5-18-82 323 1370*130

<0.4

<15

<15 5-25-82 354 1440i240

<0.4

<15

<15 6-01-82 412 1450i190

<0.4

<15

<20 6-08-82 455 1570t220

<0.4

<15

<15 6-15-82 493 1440i190

<0.4

<15

<15 6-22-82 525 1550i200

<0.4

<15

<15 6-29-82 564 1600t160

<0.4

<15

<15 7-06-82 612 1420i190

<0.4

<15

<15 7-13-82 649 1420i190

<0.4

<15

<15 7-20-82 698 1710*150

<0.4

<15

<15 7-27-82 728 1550i240

<0.4

<15

<15 8-03-82 787 1610i200

<0.4

<15

<15 2

8-10-82 822 1680i170

<0.4

<15

<15 8-17-82 858 1720i230

<0.4

<15

<15 8-24-82 895 1790*110

<0.4

<15

<15 8-31-82 936 1630i210

<0.4

<15

<17 9-07-82 979 1660*230

<0.4

<15

<15 hs 9-14-82 1018 1610*170

<0.4

<15

<15 9-21-82 1066 1620il10

<0.4

<15

<15 9-28-82 1104 1560i220

<0.4

<15

<15 Annual mean i s.d.

1540+140

<0.4

<15

<20 1

l 47

MAZLATON CNVIRONMINTAL CCl!NC"j3 Table 26.

(continued)

Location and Lab Activity (pCi/1)

Date Collected Code K-40 I-131 Cs-137 3a-La-1408 0-101 5-04-82 DMI-248 1870*140

<0.4

<l5

<l5 5-11-82 285 1790i160

<0.4

<l5

<l5 5-18-82 324,5 l'i70*100

<0.4

<l5

<l5 5-25-82 355 1780t170

<0.4

<l5

<l5 6-01-82 413 1510il90

<0.4

<l5

<l5 6-08-82 456,7 1810il70

<0.4

<15

<l5 6-15-82 494 1600i210

<0.4

<l5

<l5 6-22-82 526 1860il60

<0.4

<l5

<l5 6-29-82 565 1760i160

<0.4

<15

<l5 7-06-82 613 1860i230

<0.4

<l5

<15 7-13-82 650 1750*220

<0.4

<l5

<l5 7-20-32 699 1670i210

<0.4

<15

<l5 7-27-82 729 1830t250

<0.4

<l5

<15 8-03-82 788 1570i210

<0.4

<l5

<l5 8-10-82 823 1740*180

<0 A

<l5

<19 8-17-82 859 1810tl60

<0. 3

<l5

<l5 8-24-82 896 2040il20

<0.4

<l5

<l5 8-31-82 937 2180t150

<0.4

<l5

<l5 9-07-82 980 1890t60

<0.4

<l5

<l5 Oi 9-14-82 1019 2090il20

<0.4

<l5

<15 9-21-82 1067 2020i70

<0.4

<l5

<l5 9-28-82 1105 2210i270

<0.4

<l5

<l5 Annual mean i s.d.

1840t180

<0.4

<l5

<l5 l

I O

48

HAZLETON GNVIRONMENTAL SCCNCE3 Tahle 26.

(continued)

Location and Lab Activity (pCi/1)

Date Collected Code K-40 1-131 Cs-137 Ba-La-140a D-104 5-04-82 DMI-249 1250t130

<0.4

<l5

<15 5-11-82 286 780i100

<0.4

<15

<l5 5-18-82 326 1340i180

<0.4

<15

<15 5-25-82 356 1020il70

<0.4

<l5

<15 6-01-82 414 1100il90

<0.4

<15

<19 6-08-82 458 1120t190

<0.4

<15

<15 6-15-82 495 1300il20

<0.4

<l5

<l5 6-22-82 NDb ND ND ND ND 6-29-82 566 1190i140

<0.4

<l5

<l5 7-06-82 614 1310t160

<0.4

<l5

<15 7-13-82 651 1320*140

<0.4

<l5

<15 7-20-82 700 1370i90

<0.4

<15

<15 7-27-82 730 1550t100

<0.4

<15

<15 8-03-82 789 1580il10

<0.4

<15

<15 8-10-82 824 1180i150

<0.4

<l5

<l5 8-17-82 860 950il90

<0.4

<l5

<15 8-24-82 897 1320i200

<0.4

<15

<15 c

D-106 T3T-82 938 1530i210

<0.4

<15

<15 9-07-82 981 1480i100

<0.4

<15

<17 9-14-82 1020 1370150

<0.4

<l5

<l5 9-21-82 1068 1510i100

<0.4

<15

<15 9-28-82 1106 1460i50

<0.4

<l5

<15 Annual mean i s.d.

1290t210

<0.4

<15

<19 49

HAZLETON CNVIRONMENTAL CCEINCZ']

}

Table 26.

(continued)

Location and Lab Activity (pCi/1)

Date Collected Code K-40 1-131 Cs-137 Ba-La-140a Indicator Composited 5-04-82 DMI-250 1210i180

<0.4

<15

<15 5-11-828 287 1130i210

<0.4

<15

<15 l

5-18-82 327 1340i190

<0.4

<15

<15 5-25-82 357 1350i140

<0.4

<15

<15 6-01-82 415 1270*200

<0.4

<15

<15 6-08-82 459 1560i200

<0.4

<15

<15 6-15-82 497 1720*210

<0.4

<15

<15 6-22-82 527 1710*220

<0.4

<15

<15 6-29-82 567 1200i130

<0.4

<15

<15 7-06-82 615 1260il70

<0.4

<15

<15 7-13-82 651 1130i180

<0.4

<15

<15 7-20-82 701 1390i210

<0.4

<15

<15 7-27-82 731 1520i110

<0.4

<15

<15 8-03-82 790 860i200

<0.4

<15

<15 8-10-82 825 1050*120

<0.4

<15

<15 8-17-82 861 1250il50

<0.4

<15

<15 8-24-82 898 1440iS0

<0.4

<15

<15

{/}

8-31-82 939 1230 ISO

<0.4

<15

<15 s_

9-07-82 982 1440iS0

<0.4

<15

<15 9-14-82 1021 1230*150

<0.4

<15

<15 9-21-82 1069 1310il70

<0.4

<15

<15 9-28-82 1107 1520i110

<0.4

<15

<15 Annual mean i s.d.

1320*210

<0.4

<15

<15 O

50

-nw-n-

HazLETON ENVIRONMENTAL SCENCEJ Table 26.

(continued)

Location and Lab Activity (pC1/1)

Date Collected Code K-40 I-131 Cs-137 Ba-La-1408 Control C_ompositef 5-04-82 DMI-251 1370i130

<0.4

<l5

<15 5-11-82 288 1330il20

<0.4

<15

<15 5-18-82 328 1250i180

<0.4

<15

<15 5-25-82 358 1210i180

<0.4

<l5

<15 6-01-82 416 1140*180

<0.4

<15

<15 6-08-82 460 1470i140

<0.4

<15

<l5 6-15-82 498 1290il50

<0.4

<15

<15 6-22-82 528 1530i240

<0.4

<15

<15 6-29-82 568 1240t130

<0.4

<l5

<15 7-06-82 616 1120il90

<0.4

<l5

<20 7-13-82 653 1210i140

<0.4

<15

<15 7-20-82 702 1290il40

<0.4

<15

<15 7-27-82 732 1280il50

<0.4

<15

<15 8-03-82 791 720t70

<0.4

<15

<15 8-10-82 826 790i60

<0.4

<15

<15 P

8-17-82 862 1500 ISO

<0.4

<1:i

<15

\\

8-24-82 899 1490i90

<0.4

<15

<15 8-31-82 940 1400i100

<0.4

<15

<l5 9-07-82 983 1140il20

<0.4

<15

<15 l

9-14-82 1022 1190150

<0.4

<15

<15 9-21-82 1070 1370t100

<0.4

<l5

<15 l

9-28-82 1108 1170iS0

<0.4

<l5

< 15_

Annual mean i s.d.

1250i200

<0.4

<15

<20

  • Ba-140 minimum sensitivity is at counting time.

ND = No Data. Sample not available.

c D-106 replaces D-104 starting 8-24-82 because farmer at location D-104 has gone out of the dairy business.

d Composite of samples from locations D-72 and 0-96 e Composite does not include location D-96. Sample not available.

f Composite of samples from locations D-102 and D-73 (before 12 May, 1982) i l

and locations D-102 and D-105 (after 12 May,1982).

O 51

MAZl.ETON ENVIRONMENTAL SCCNC"I.3 Table 27.

Milk samples collected during the grazing season, analysis for strontium-89, strontium-90 and elemental calcium.

Collection: Monthly Composites - May through September t

Location and Lab Calcium Activity (pCi/1)

Date Colle::ted Code g/l Sr-89 Sr-90 Indicator D-63 May Comp.

DMI-389 1.1

<10 2.7i0.8 June Comp.

580 1.3

<10 2.0i0.6 July Comp.

747 1.0

<10 2.8i0.7 Aug.

Comp.

952 1.2

<10 2.1.*0. 7 Sept. Comp.

1120 1.3

<10 2.6t0.8 Annual Mean i s.d.

1.2i0.1

<10 2.4i0.4 D-72 May Comp.

DMI-390 1.1

<10 1.9*1.0 q

June Comp.

581 1.2

<10 1.7i0.5 Q

July Comp.

748 1.2

<10 1.9i0.6 Aug.

Comp.

961 1.1

<10 1.8i0.5 Sept. Comp.

1121 1.2

<10 2.1*0.8 Annual Mean i s.d.

1.2 0.1

<10 1.9i0.1 l

D-93 I

May Comp.

DMI-391 1.4

<10 7.9tl.6 June Comp.

582 1.4

<10 6.7i0.7 July Comp.

749,50 1.5

<10 5.5i0.8 Aug.

Comp.

953 1.3

<10 4.li0.8 Sept. Comp.

1122 1.2

<10 4.9tl.0 Annuai Mean i s.d.

1.4 0.1

<10 5.8tl.5 52

HAZLETON GNVIRONMENTAL CCCNCE3 Table 27 (continued)

Locat'cn and Lab Calcium Activity (pci/1)

Date Collected Code g/l Sr-89 Sr-90 D-94 May Comp.

DMI-392 1.3

<10 4.9i0.9 June Comp.

583 1.4

<10 5.0i0.7 July Comp.

751 1.3

<10 3.8i0.7 Aug.

Comp.

954 1.3

<10 5.4i2.4 Sept. Comp 1123 1.3

<10 2.2i0.8 Annual Mean i s.d.

1.520.1

<10 4.3*1.3 D-96 May Comp.

DMI-393 1.3

<10 3.2i2.1 June Comp.

584 1.2

<10 2.1*0.6 July Comp.

752 1.2

<10 1.6i0.7 Aug. Comp.

955 1.2

<10 1.8i0.7 O

Sept. Comp.

1124 1.2

<10 1.7i0.8 Annual Mean i s.d.

1.2i0.1

<10 2.110.7 D-101 May Comp.

DMI-394 1.3

<10 2.4tl.3 June Comp.

585 1.1

<10 2.5i0.8 July Comp.

753 1.1

<10 3.110.7 Aug.

Comp.

956,7 1.2

<10 4.6i0.6 Sept. Comp.

1125,6 1.1

<10 2.3i0.7 Annual Mean i s.d.

1.210.1

<10 3.0il.0

.O V

53

HAZLETON CNVIRQNMENTAR. SCCNCE3 Table 27.

(continued)

Location and Lab Calcium Activity (pCi/1)

I Date Collected Code g/l Sr-89 Sr-90 D-104a May Comp.

DMI-396 1.4

<10 4.9i0.8 June Comp.

586,7 1.3

<10 2.7 0.5 July Comp.

755 1.3

<10 7.8i0.9 Aug.

Comp.

959 1.4

<10 3.6i0.6 D-106 Sept. Comp.

DMI-1129 1.3

<10 2.0i0.6 Annual Mean i s.d.

1.3i0.1

<10 4.2i2.3 Control D-102 May Comp.

DMI-395 1.3

<10 2.7i0.8 June Comp.

588 1.2

<10 9.7i0.9 i

July Comp.

754 1.2

<10 2.6i0.7 Aug. Comp.

958 1.1

<10 2.0t0.7 Sept. Comp.

1127 1.2

<10 2.0i0.5 Annual Mean i s.d.

1.2i0.1

<10 3.8t3.3 D-105 May Comp.

DMI-397 1.2

<10 2.5tl.6 June Comp.

589 1.6

<10 4.3i0.7 JJ1y Comp.

756 1.1

<10 1.8i0.5 Aug.

Comp.

960 1.1

<10 1.8i0.5 Sept. Comp.

1128 1.3

<10 2.4i0.7 Annual Mean i s.d.

1.3i0.2

<10 2.6tl.0

  • Location D-104 was replaced by Location D-106 starting 8-24-82.

O 54

Ha Fi IPTON ENVIRIiNMENTAL. CCl!_NC'3D Table 28.

Ground water samples, analysis for gross beta.

Collection: Monthly Location and Lab Gross Beta Location and Lab Gross Beta Date Collected Code (pCi/1)

Date Collected Code (pCi/1) 0-53 D-54 Treated Municipal Inlet to Municipal Water Water Treatment 1/82 DWW-338 3.2i0.5 1/82 DWW-339 2.910.5 2/82 554,5 2.8i0.4 2/82 556 1.9i0.5 3/82 806 2.8i0.6 3/82 807,8 2.3*0.4 4/82 1197 2.7i0.6 4/82 1198 3.li0.6 5/82 1515 2.1*0.5 5/82 1516 3.3t0.6 6/82 1783 3.2i0.7 6/82 1784 2.7t0.6 7/82 2179 2.2i0.5 7/82 2180 3.2i0.6 8/82 2455 2.610.6 8/82 2456 3.1i0.7 9/82 2761 2.6i0.5 9/82 2762 2.7i0.5 10/82 3128 3.3i0.7 10/82 3129 3.3i0.7 11/82 3444,5 2.9i0.5 11/82 3446 7.2i2.3 12/82 3748 3.0i0.6 12/82 3749 3.8tl.1 Annual Mean i s.d.

2.8i0.4 Annual Mean i s.d.

3.3tl.3 D-55 D-57 On-Site Well Bull 1/29/82 DWW-267,8 2.010.4 1/29/82 DWW-269 1.Si0.5 2/22/82 473 2.li0.5 2/22/82 474,5 1.6i0.3 3/29/82 802 3.3i0.7 3/29/82 803 1.7i0.6 4/26/82 1199,1200 0.7i0.3 4/?C/82 1201 1.4i0.5 5/24/82 1437 1.li0.5 5/24/82 1438 1.510.5 6/30/82 1785 0.7i0.5 6/30/82 1786 0.8i0.5 7/27/82 2181 1.6i0.5 7/27/82 2182 1.4i0.5 8/30/82 2457 1.2i0.6 8/30/82 2458 0.8i0.6 9/30/82 2723

<0.8 9/27/82 2724 2.0iO.5 10/26/82 3119 2.4i0.6 10/26/82 3120 2.0i0.6 11/29/82 3439 2.210.6 11/29/82 3440 2.010.9 12/27/82 3717 1.7*0.5 12/27/82 3718 1.410.7 Annual Mean i s.d.

1.7i0.8 Annual Mean i s.d.

1.5i0.4 O

55

HAZLETON ENVIRONMZNTAL SCC.NCE3 Table 28.

(continued)

Location and Lab Gross Beta Location and Lab Gross Beta Date Collected Code (pCi/1)

Date Collected Code (pCi/1)

D-58 D-59 Frantz Frantz Cottage 1/29/82 DWW-270 6.0i0.5 1/82 ND" ND 2/22/82 476 4.2*0.6 2/82 3/29/82 804 4.8i0.7 3/82(3-29-82)

DWW-805 3.Si0.6 4/26/82 1202 4.5*0.7 4/82(4-26-82) 1203 3.0*0.6 5/24/82 1439 4.5t0.6 5/24/82 1440 2.li0.5 6/30/82 1787 3.4i0.7 6/30/82 1788 3.8i0.7 7/27/82 2183,4 1.110.3 7/27/82 2185 5.1i0.7 8/30/82 2459 4.7i0.8 8/30/82 2460 3.4i0.7 9/27/82 2725,6 4.5i0.4 9/27/82 2727 3.6i0.6 10/26/82 3121 6.7i0.8 10/26/82 3122 5.li0.8 11/29/82 3441 7.9tl.2 11/29/82 3442 4.3tl.0 12/27/82 3719,20 5.7i0.9 12/27/82 3721 4.6i0.9 Annual Mean i s.d.

4.8 1.7 Annual Mean i s.d.

3.9tl.0 D-60 e

Comp a

ND i

1/82

^

ND 2/82 b

NC 3/82 NC 4/82 NC 5/82 NC 6/82 7/27/82 DWW-2186 1.2i0.5 8/30/82 2461 1.li0.5 9/27/82 2728 1.lil.4 10/26/82 3130 1.0i0.5 11/29/82 3443 1.6i0.7 12/27/82 3722 1.0*0.4 Annual Mean i s.d.

1.2i0.2 a ND = No Data. Samples were not collected due to frozen well.

NC = No Collection.

Pump was still off.

c New location replaces Wiley Farm. Collection started 7/27/82.

O 56

HAZLETON ENVIRONMINTAL CCENCEJ On Table 29.

Well water samples, quarterly composites of monthly samples, V

analysis for gross beta and tritium.

Location and Lab Activity (pC1/1)

Date Collected Code Gross Beta H-3 D-53 Treated Municipal Water 1st Q, 1982 DWW-853 2.6i0.6

<330 l

2nd Q, 1982 1832 2.2i0.6

<330 3rd Q, 1982 2801 2.7i0.5

<330 1

4th Q, 1982 3788 2.5i0.6

<330 Annual Mean t s.d.

2.5*0.2

<330 D-54 Inlet to Municipal Water Treatment 1st Q, 1982 DWW-854 8.0i0.8

<330 2nd Q, 1982 1833,4 2.5i0.4

<330 3rd Q, 1982 2802 3.5i0.6

<330 4th Q, 1982 3789 4.lil.2

<330 Annual Mean i s.d.

4.5i2.4

<330 J

D-55 On-site Well 1st Q, 1982 DWW-855 1.9i0.5

<330 2nd Q, 1982 1835 0.7i0.6

<330 3rd Q, 1982 2803 1.2t0.5

<330 4th Q, 1982 3790 1.9i0.5

<330 Annual Mean i s.d.

1.4i0.6

<330 D-57 Bull 1st Q, 1982 DWW-856 2.li0.6

<33G 2nd Q, 1982 1836 1.6*0.6

<330 3rd Q, 1982 2804 1.110.5

<330 4th Q, 1982 3791 1.210.7

<330 Annual Mean i s.d.

1.Si0.5

<330 57

HAZLETON CNVIRONMENTAL. CCCNCEJ O

Table 29.

(continued)

Location and Lab Activity (pCi/1)

Date Collected Code Gross beta H-3 D-58 Frantz lst Q, 1982 DWW-857 5.3i0.7

<330 2nd Q, 1982 1837 5.8f0.8

<330 3rd Q, 1982 2805 3.2i0.6

<330 4th Q, 1982 3792 6.4fl.0

<330 Annual Mean i s.d.

5.2il.4

<330 l

D-59 Frantz Cottage 1st Q, 1982 DWW-858a 3.5t0.6

<330 2nd Q, 1982 1838 3.lt0.6

<330 3rd Q, 1982 2806 1.7i0.5

<330 4th Q, 1982 3793 4.3*0J

<330 Annual Mean i s.d.

3.2il.1

<330 D-60 Willey NDb ND 1st Q, 1982 ND ND 2nd Q, 1982 3rd Q, 1982 DWW-2807 1.5i0.5

<330 4th Q, 1982 3794,5 1.0i0.6

<330 Annual Mean i s.d.

1.3i0.4

<330

  • Only sample collected in March is included in the composite, because there were no collections in January and February due to frozen well.

b No Data. No sample collections because well was off.

l O

1 58

HA78 NN CNVIRONMENTAL SC11NCD Table 30.

Vegetation Ecmples (broad leaf), analysis for ;udine-131.

Collection: Annualiy.

Date Lab Activity (pCi/g) wet Location Collected Code I-131 Indicator D-57 7-26-82 DG-65

<0.028 D-58 7-26-82 DG-66

<0.029 D-63 7-27-82 DG-67

<0.034 D-72 7-30-82 DG-68,69

<0.029 D-93 7-27-82 DG-70

<0.023 D-94 7-13-82 DG-54

<0.070 D-96 7-27-82 DG-71

<0.036 D-101 7-27-82 DG-72

<0.048 '

D-104 7-30-82 DG-73

<0.026 Control a

D-102 9-21-82 DG-106

<0.050 D-105 7-20-82 DG-64

<0.031

  • Grass in lieu of broad leaf vegetation sample.

O 59

HAZl ETON ENVIRONMENTAL CCl2NCEJ Table 31.

Vegetation samples analysis for strontium-90 and gamma-emitting isotopes.

Collection: Annually.

l Sample Description and Activity (pCi/g wet) l Indicator Location D-57 D-58 D-63 D-63 Date Collected 11-08-82 11-08-82 11-02-82 11-02 82 Type Dried corn Dried corn Dried corn Hay Lab Code DVE-83 DVE-82 DVE-68 DVE-87 Sr-90

<0.006

<0.008

<0.004 0.213i0.024 K-40 3.09i0.54 5.42i0.41 2.94i0.21 13.10*0.86 Mn-54

<0.048

<0.017

<0.034

<0.11 Co-58

<0.080

<0.028

<0.052

<0.16 Co-60

<0.054

<0.017

<0.033

<0.16 Nb-95

<0.11

<0.045

<0.086

<0.27 Zr-95

<0.12

<0.056

<0.11

<0.33 Ru-103

<0.085

<0.047

<0.078

<0.23 Ru-106

<0.42

<0.20

<0.31

<1.15 Cs-134

<0.043

<0.033

<0.036

<0.12 Cs-137

<0.044

<0.023

<0.034

<0.12

(")

Ce-141

<0.15

<0.091

<0.12

<0.46 Ce-144

<0.28

<0.17

<0.23

<0.86 Location D-72 D-72 0-93 0-93 Date Collected 11-02-82 11-16-82 11-02-82 11-02-82 Type Dried corn Hay Dried corn Soy beans l

Lab Code DVE-69 OVE-88,9 DVE-70 DVE-76 Sr-90

<0.005 0.159*0.023

<0.003 0.033i0.011 K-40 3.58i0.61 19.20tl.68 2.87i0.53 12.20*1.10 i

Mn-54

<0.040

<0.096

<0.053

<0.051 Co-58

<0.070

<0.12

<0.072

<0.075 Co-60

<0.041

<0.089

<0.049

<0.050 1

Nb-95

<0.11

<0.15

<0.11

<0.13 l

Zr-95

<0.11

<0.22

<0.13

<0.14 l

Ru-103

<0.087

<0.13

<0.095

<0.11 Ru-106

<0.45

<0.70

<0.37

<0.43 Cs-134

<0.044

<0.072

<0.04

<0.041 Cs-137

<0.049

<0.076

<0.053

<0.053 Ce-141

<0.13

<0.22

<0.12 (0.25 Ce-144

<0.23

<0.48

<0.23

<0.44 O

60

HAZLETON CNVIRONMENTAL SCl2NCE3 Table 31.

(continued)

Sample Description and Activity (pCi/g wet)

Location D-93 D-94 D-94 D-94 Date Collected 11-16-82 11-03-82 11-03-82 11-16-82 Type Hay 3ried corn Soy beans Hay Lab Code DVE-90 DVE-71 DVE-77,8 DVE-91 Sr-90 0.140*0.027

<0.003 0.031i0.006 0.311i0.028 K-40 12.50il.85 2.24i0.47 8.09i0.36 8.50il.50 Mn-54

<1.30

<0.020

<0.056

<0.056 Co-58

<0.18

<0.022

<0.079

<0.060 Co-60

<0.14

<0.022

<0.055

<0.074 Nb-95

<0.32

<0.048

<0.13

<0.091 Zr-95

<0.36

<0.063

<0.15

<0.23 Ru-103

<0.23

<0.065

<0.11

<0.15 Ru-106

<1.33

<0.20

<0.45

<0.91 Cs-134

<0.13

<0.025

<0.039

<0.054 Cs-137

<0.13

<0.023

<0.052

<0.088 Ce-141

<0.52

<0.085

<0.29

<0.19

()

Ce-144

<0,"1

<0.14

<0.51

<0.59 Location D-96 D-96 D-96 D-10^

l Date Collected 11-02-82 11-02-82 11-16-82 11-16-02 l

Type Dried corn Soy beans Hay Hay Lab Code DVE-72 DVE-79 DVE-92 DVE-93 Sr-95

<0.003 0.055i0.018 0.260i0.029 0.344t0.027 i

l K-40 2.91 0.48 15.30il.64 11.90i2.10 7.57i0.98 l

Mn-54

<0.041

<0.086

<0.15

<0.042 Co-58

<0.054

<0.10

<0.24

<0.048 l

Co-60

<0.042

<0.089

<0.18

<0.037 Nb-95

<0.10

<0.25

<0.40

<0.079 Zr-95

<0.12

<0.26

<0.46

<0.11 Ru-103

<0.063

<0.17

<0.33

<0.078 Ru-106

<0.31

<0.69

<1.51

<0.40 Cs-134 (0.036

<0.065

<0.15

<0.039 Cs-137

<0.032

<0.089

<0.15

<0.060 Co-141

<0.12

<0.41

<0.61

<0.19 Ce-144

<0.23

<0.75

<1.16

<0.36 O

61

Hart ETON GNVIR'ZNMENTAL SclZMCE'3 Table 31.

(continued)

Sample Description and Activity (pCi/g wet) location 0-106 D-106 Date Collected 11-02-82 11-16-82 Type Dried corn Hay Lab Code DVE-75 DVE-96 i

Sr-90

<0.004 0.264i0.026 K-40 3.39i0.53 12.60il.05 Mn-54

<0.042

<0.066 Co-58

<0.060

<0.099 Co-60

<0.034

<0.076 Nb-95

<0.088

<0.15 Zr-95

<0.11

<0.17 Ru-103

<0.094

<0.13 Ru-106

<0.38

<0.64 Cs-134

<0.039

<0.066 Cs-137

<0.042

<0.065 l

Ce-141

<0.23

<0.27 I

Ce-144

<0.043

<0.52 O

l l

t O

62

I HA21.ETON ENVIRONMENTAL SClZNCEJ Table 31.

(continued)

Sample Description and Activity (pCi/g wet)

CONTROL Location D-102 D-102 D-10P Date Collected 11-02-82 11-02-82 11-16-82 Type Dried corn Soy beans Hay Lab Code DVE-73 DVE-80 DVE-94 Sr-90

<0.003 0.05410.025 0.16020.034 K-40 3.00i0.24 12.61tl.10 12.10 1.92 Mn-54

<0.039

<0.048

<0.15 Co-58

<0.054

<0.045

<0.24 Co-60

<0.032

<0.039

<0.13 Nb-95

<0.082

<0.053

<0.36 Zr-95

<0.099

<0.091

<0.36 Ru-103

<0.088

<0.079

<0.32 Ru-106

<0.35

<0.37

<1.43 Cc-134

<0.034

<0.040

<0.16 l

C -137

<0.037

<0.045

<0.15 Ce-141

<0.20

<0.16

<0.64 Ce-144

<0.38

<0.23

<1.33 Location D-105 D-105 D-105 Date Collected 11-02-82 11-02-82 11-16-82 Type Dried corn Soy beans Hay Lab Code DVE-74 DVE-81 DVE-95 Sr-90

<0.004 0.042t0.023 0.21910.029 K-40 2.84i0.22 14.70il.44 13.40i0.48 Mn-54

<0.039

<0.065

<0.064 Co-58

<0.056

<0.076

<0.093 Co-60

<0.040

<0.074

<0.056 Nb-95

<0.085

<0.18

<0.081 Zr-95

<0.099

<0.21

<0.11 Ru-103

<0.081

<0.15

<0.084 Ru-106

<0.31

<0.68

<0.66 Cs-134

<0.032

<0.060

<0.047 Cs-137

<0.039

<0.065

<0.065 Ce-141

<0.20

<0.38

<0.13 Ce-144

<0.35

<0.62

<0.34 O

63

HAZLETCN CNVIRONMENTAL SCCNC2'3 Table 32.

Meat and poultry samples, analysis of edible portion for gamma-emitting isotopes.

Collection: Annually.

Sample Description and Activity (pCi/g wet)

Outside 10 Miles of Plant Location D-94 Bill Cook Floyd Young Date Collected 10-05-82 9-28-82 9-28-82 Type Chicken Beef Park Lab Code DME-9 DME-13 DME-15 K-40 2.31i0.43 3.18i0.47 2.5110.47 Mn-54

<0.015

<0.023

<0.031 Co-58

<0.029

<0.026

<0.023 Co-60

<0.020

<0.026

<0.023 Nb-95

<0.028

<0.034

<0.037 Zr-95

<0.045

<0.073

<0.048 Ru-103

<0.053

<0.091

<0.060 Ru-106

<0.19

<0.28

<0.29 Cs-134

<0.020

<0.031

<0.025 Cs-137

<0.023

<0.026

<0.028 Ce-141

<0.10

<0.074

<0.074 Ce-144

<0.22

<0.26

<0.16 Inside 10 Miles of Plant Location D-102 Eugene Hugh's Paul Quass Date Collected 10-05-82 9-23-82 10-18-82 Type Chicken Beef Pork l

Lab Code DME-10,11 DME-12 DME-14 K-40 2.74i0.29 2.62i0.51 2.48i0.42 Mn-54

<0.026

<0.022

<0.023 Co-58

<0.031

<0.047

<0.043 Co-60

<0.023

<0.019

<0.034 Nb-95

<0.034

<0.026

<0.026 Zr-95

<0.047

<0.064

<0.070 Ru-103

<0.065

<0.040

<0.088 l

Ru-106

<0.20

<0.26

<0.23 Cs-134

<0.025

<0.022

<0.025 Cs-137

<0.019

<0.043

<0.025 Ce-141

<0.081

<0.067

<0.071 Ce-144

<0.16

<0.13

<0.16 64 l

HATE INTON CNVIRONMENTAL SCl2NCCD O

Table 33.

Wildlife sample, analysis for gamma-emitting isotopes.

Collection: Annually.

Sample Description and Activity (pCi/g wet)

Insida 10 Miles of Plant Location (300' from site front gate)

Date Collected 1-28-82 Type Squirrel Lab Code DWL-1 K-40 3.61*0.62 Mn-54

<0.050 Co-58

<0.088 Co-60

<0.050 Nb-95

<0.17 Zr-95

<0.14 Ru-103

<0.11 Ru-106

<0.37 Cs-134

<0.056 Cs-137

<0.064 Ce

<0.33 O

ce-141

-144

<o 39 O

65

HAZLETON ENVIRONMENTAL SCI'lNC:'J.3 0V Table 34.

Soil samples, analysis for strontium-90 and gamma-emitting isotopes.

Collection: Tri-annually.

Sample Description and Activity (pCi/g dry)

Indicator Location D-15 0-15 D-15 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-1 DS0-75 DS0-90 Sr-90 0.103i0.011 0.071i0.012 0.034i0.013 K-40 16.68i0.92 16.62*1.30 16.68i0.97 Mn-54

<0.056

<0.079

<0.056 Co-58

<0.033

<0.064

<0.059 Co-60

<0.060

<0.079

<0.040 Nb-95

<0.034

<0.059

<0.060 Zr-95

<0.047

<0.13

<0.11 Ru-103

<0.073

<0.17

<0.077 Ru-106

<0.28

<0.76

<0.51 Cs-134 0.168i0.033

<0.088

<0.062 Cs-137 0.377i0.046 0.193i0.049 0.141 0.038 Ce-141

<0.079

<0.12

<0.13 Ce-144

<0.25

<0.43

<0.26 Location D-16 D-16 D-16 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-2 DS0-76 DS0-91 Sr-90 0.111*0.013 0.067i0.014 0.074i0.015 K-40 16.75tl.40 11.53i0.99 11.06i0.86 Mn-54

<0.057

<0.048

<0.043 Co-58

<0.045

<0.042

<0.042 Co-60

<0.054

<0.070

<0.047 Nb-95

<0.073

<0.057

<0.036 Zr-95

<0.076

<0.099

<0.057 Ru-103

<0.048

<0.087

<0.071 Ru-106

<0.51

<0.47

<0.25 Cs-134

<0.078

<0.039

<0.034 Cs-137 0.410i0.057 0.208i0.040 0.214i0.035 Ce-141

<0.063

<0.093

<0.099 Ce-144

<0.28

<0.23

<0.20 O

V 66

MAZLATON CNVIRONMENTAL CCENC~D O

Table 34.

(continued)

Sample Description and Activity (pCi/g dry)

Indicator Location D-57 D-57 D-57 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-3 DS0-77,8 DS0-92 Sr-90 0.150i0.019 0.10510.010 0.094i0.016 K-40 19.56tl.50 19.35i0.92 15.60il.20 Mn-54

<0.023

<0.068

<0.062 Co-58

<0.028

<0.050

<0.059 Co-60

<0.034

<0.065

<0.065 Nb-95

<0.050

<0.074

<0.051 Zr-95

<0.064

<0.11

<0.081 Ru-103

<0.036

<0.093

<0.10 Ru-100

<0.15

<0.45

<0.36 Cs-134

<0.043

<0.078

<0.048 Cs-137

<0.057 0.563i0.048 0.302*0.050 Ce-141

<0.051

<0.17

<0.14 Ce-144

<0.15

<0.38

<0.29 Location D-58 D-58 U-58 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS 0-4 050-79 DS0-93 Sr-90 0.183i0.013 0.212i0.024 0.194i0.020 K-40 15.51i0.89 14.68i0.89 14.45tl.10 Mn-54

<0.054

<0.036

<0.034 l

Co-58

<0.039

<0.037

<0.054 i

Co-60

<0.070

<0.057

<0.053 Nb-95

<0.034

<0.040

<0.057 Zr-95

<0.060

<0.090

<0.087 Ru-103

<0.096

<0.064

<0.078 Ru-106

<0.37

<0.39

<0.50 Cs-134

<0.045

<0.048

<0.068 Cs-137 0.579i0.050 0.534t0.050 0.53110.060 Ce-141

<0.073

<0.087

<0.096 Ce-144

<0.25

.: <0.22

<0.28 4

l O

67

HAZLETON ENVIRINMENTAL CCENCO Table 34.

(continued)

Sample Description and Activity (pCi/g dry)

Indicator Location D-63 0-63 D-63 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-5 050-80 DS0-94 Sr-90 0.109i0.011 0.297i0.025 0.285i0.022 K-40 18.69tl.20 16.25tl.30 16.72il.40 Mn-54

<0.068

<0.059

<0.064 Co-58

<0.074

<0.045

<0.056 Co-60

<0.056

<0.057

<0.060 Nb-95

<0.071

<0.062

<0.12 Zr-95

<0.11

<0.12

<0.096 Ru-103

<0.11

<0.13

<0.15 Ru-106

<0.53

<0.65

<0.79 Cs-134

<0.074

<0.090

<0.10 Cs-137 0.390i0.053 1.3710.095 1.27i0.099 Ce-141

<0.11

<0.17

<0.20 Ce-144

<0.29

<0.37

<0.40 Location D-72 0-72 D-72 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DSD-6 0S0-81 0S0-95 Sr-90 0.129i0.013 0.138i0.022 0.13210.015 K-40 16.69i0.93 14.40tl.10 15.16*1.10 Mn-54

<0.048

<0.068

<0.057 Co-58

<0.060

<0.060

<0.036 l

Co-60

<0.043

<0.068

<0.057 Nb-95

<0.067

<0.082

<0.079 Zr-95

<0.082

<0.091

<0.10 Ru-103

<0.067

<0.13

<0.14 Ru-106

<0.28

<0.37

<0.50 Cs-134

<0.051

<0.071

<0.057 Cs-137 0.402i0.044 0.299i0.045 0.350i0.049 Ce-141

<0.11

<0.17

<0.096 Ce-144

<0.23

<0.29

<0.34 O

68 I

HAZLETON ENVIRONM NTAL. CClZNC22 Table 34.

(continued)

Sample Description,and Activity (pCi/g dry)

Indicator Location D-93 0-93 0-93 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-7 DS0-82 DS0-96 Sr-90 0.135i0.015 0.191i0.023 0.164i0.016 K-40 16.84tl.00 17.31tl.20 17.95tl.30 Mn-54

<0.064

<0.056

<0.045 Co-58

<0.059

<0.057

<0.057 Co-60

<0.067

<0.051

<0.057 Nb-95

<0.082

<0.084

<0.060 Zr-95

<0.11

<0.084

<0.11 Ru-103

<0.15

<0.11

<0.12 Ru-106

<0.42

<0.50

<0.43 Cs-134

<0.060

<0.067

<0.088 Cs-137 0.310i0.047 0.386i0.049 0.487i0.063 Ce-141

<0.13

<0.19

<0.016 Ce-144

<0.28

<0.31

<0.33 O

Location D-94 D-94 D-94 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-8 0S0-83 DS0-97 Sr-90 0.226i0.014 0.254i0.035 0.227i0.020 K-40 13.67i0.81 15.80tl.40 13.41tl.10 Mn-54

<0.031

<0.071

<0.053 Co-58

<0.039

<0.070

<0.048 Co-60

<0.056

<0.065

<0.045 Nb-95

<0.060

<0.099

<0.059 Zr-95

<0.079

<0.19

<0.11 Ru-103

<0.058

<0.20

<0.10 Ru-106

<0.43

<0.64

<0.51 i

l Cs-134

<0.036

<0.087

<0.053 Cs-137 0.56010.048 0.730i0.081 0.60010.064 Ce-141

<0.095

<0.25

<0.13 Ce-144

<0.25

<0.64

<0.33 O

69

HAZLETON CNVIRONMENTAL SclZNCE3 Table 34.

(continued)

Sample Description and Activity (pCi/g dry)

Indicator Location D-96 D-96 D-96 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-9 DS0-84 DS0-98 Sr-90 0.160i0.017 0.14910 022 0.125i0.017 K-40 18.60il.20 16.97tl.50 17.38tl.40 Mn-54

<0.087

<0.067

<0.054 Co-58

<0.076

<0.053

<0.098 Co-60

<0.062

<0.090

<0.087 Nb-95

<0.098

<0.12

<0.12 Zr-95

<0.090

<0.14

<0.12 Ru-103

<0.095

<0.14

<0.24 Ru-106

<0.54

<0.54

<0.88 Cs-134

<0.082

<0.079

<0.10 Cs-137 0.665i0.071 0.622i0.085 0.464i0.067 Ce-141

<0.19

<0.16

<0.17 Ce-144

<0.33

<0.43

<0.42 Location D-101 D-101 D-101 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-10,ll DS0-85 DS0-99,100 Sr-90 0.137i0.009 0.178i0.024 0.14210.015 K-40 14.00i0.62 15.06tl.30 14.81i0.66 Mn-54

<0.050

<0.053

<0.053 Co-58

<0.026

<0.070

<0.033 Co-60

<0.060

<0.065

<0.037 Nb-95

<0.031

<0.095

<0.064 Zr-95

<0.065

<0.16

<0.068 Ru-103

<0.062

<0.15

<0.074 Ru-106

<0.31

<0.68

<0.31 Cs-134

<0.053

<0.084

<0.047 Cs-137 0.511i0.034 0.453tc.063 0.46010.024 Ce-141

<0.079

<0.22

<0.091 Ce-144

<0.23

<0.33

<0.22 O

70

MATE BTON GNVIRONMZNTAL CCCNCQ Table 34.

(continued)

Sample Description and Activity (pCi/g dry)

Indicator Location D-104 D-106 D-106 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code 0S0-13 DS0-88,89 DS0-103 Sr-90 0.040i0.007 0.020i0.007 0.058i0.014 K-40 8.26i0.64 9.96i0.54 10.05i0.64 Mn-54

<0.022

<0.028

<0.032 Co-58

<0.031

<0.039

<0.020 Co-60

<0.028

<0.040

<0.031 Nb-95

<0.025

<0.040

<0.025 Zr-95

<0.082

<0.065

<0.068 Ru-103

<0.087

<0.062

<0.050 Ru-106

<0.22

<0.19

<0.17 Cs-134

<0.033

<0.036

<0.037 Cs-137 1.37i0.066 0.10110.021 0.208i0.027 Ce-141

<0.10

<0.062

<0.056 i

Ce-144

<0.23

<0.16

<0.15 O

l 4

O 71

HAZLETON ENVIRONMENTAL SCENCE3 Table 34.

(continued)

Sample Description and Activity (pCi/g dry)

Control Location D-105 0-105 D-105 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-14 DS0-87 DS0-102 Sr-90 0.152i0.012 0.14010.018 0.12710.014 K-40 19.58tl.40 19.19tl.60 18.21tl.30 Mn-54

<0.081

<0.062

<0.047 Co-58

<0.07P

<0.099

<0.051 Co-60

<0.067

<0.088

<0.081 Nb-95

<0.056

<0.13

<0.10 Zr-95

<0.16

<0.19

<0.11 Ru-103

<0.081

<0.22

<0.16 Ru-106

<0.47

<0.90

<0.42 Cs-134

<0.078

<0.096

<0.081 Cs-137 0.558t0.067 0.550i0.080 0.477i0.060 Ce-141

<0.14

<0.25

<0.20 Ce-144

<0.32

<0.43

<0.34 Location D-102 0-102 D-102 Date Collected 4-14-82 9-21-82 9-28-82 Lab Code DS0-12 DS0-86 DS0-101 Sr-90 0.079i0.009 0.075i0.020 0.038i0.009 K-40 10.91i0.82 9.8010.85 10.0910.83 Mn-54

<0.037

<0.026

<0.042 Co-58

<0.026

<0.043

<0.039 Co-60

<0.034

<0.040

<0.065 Nb-95

<0.043

<0.067

<0.037 Zr-95

<0.070

<0.096

<0.050 Ru-103

<0.054

<0.070

<0.10 Ru-106

<0.26

<0.26

<0.23 Cs-134

<0.034

<0.050

<0.037 i

Cs-137 0.440i0.045 0.342i0.044 0.201i0.036 Ce-141

<0.070

<0.14

<0.088 Ce-144

<0.19

<0.22

<0.37 72

HAZLETON CNVIRONMENTAL CClZNCE3 Table 36.

Surface water samples, analysis for gamma-emitting isotopes.

Collection:

Monthly Locatiori Sample Description and Activity (pCi/1)

Lewis Access Indicator D-49 Date Collected 1/8{

5/24/82 9/27/82 Lab Code ND DSW-1429 DSW-2716 Mn-54

<15

<l5 Co-58

<l5

<l5 Co-60

<l5

<l5 Nb-95

<l5

<l5 Zr-95

<15

<l5 Cs-134

<l5

<15 Cs-137

<l5

<l5 Date Collected 2/22/82 6/30/82 10/26/82 Lab Code DSW-466 DSW-1775 DSW-3111 Mn-54

<l5

<l5

<l5 Co-58

<15

<l5

<15 Co-60

<15

<l5

<l5 Nb-95

<l5

<15

<l5 Zr-95

<l5

<l5

<15 l

Cs-134

<l5

<15

<l5 Cs-137

<l5

<l5

<15 Date Collected 3/29/82 7/27/82 11/29/82 Lab Code DSW-794 DSW-2171 DSW-3431 Mn-54

<l5

<l5

<15 Co-58

<15

<l5

<15 Co-60

<15

<l5

<15 Nb-95

<15

<l5

<l5 f

Zr-95

<l5

<20

<17 l

Cs-134

<l5

<l5

<15 Cs-137

<15

<15

<15 Date Collected 4/26/82 8/30/82 12/27/82 Lab Code DSW-1190 DSW-2447 DSW-3710 Mn-54

<l5

<15

<15 Co-58

<l5

<l5

<l5 Co-60

<15

<15

<15 Nb-95

<15

<17

<15 Zr-95

<15

<15

<l5 Cs-134

<l5

<15

<15 Cs-137

<l5

<l5

<15 O

73

HAZLETON Cb!VIRONMENTAL SCIINCKJ

( )

Table 36.

(continued)

Location Sample Description *tnd Activity (pCi/1)

Plant Intake Indicator D-50 Date Collected 1/29/82 5/24/82 9/27A82 Lab Code DSW-261 DSW-1430 DSW-2717 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 1

Nb-95

<l5

<15

<l5 Zr-95

<24

<15

<20 Cs-134

<15

<15

<15 Cs-137

<15

<15

<l5 Date Collected 2/22/82 6/30/82 10/27/82 Lab Code DSW-467 DSW-1776 DSW-3112 Mn-54

<15

<15

<15 Co-58

<15

<l5

<15 Co-60

<15

<15

<15 Nb-95

<15

<l5

<l5 Zr-95

<16

<15

<l5 Cs-134

<15

<15

<15 Cs-137

<15

<l5

<15 Date Collected 3/29/82 7/27/82 11/29/82 Lab Code DSW-795 DSW-2172,3 DSW-3432 Mn-54

<l5

<15

<15 Co-58

<l5

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<l5

<15 -

Zr <15

<15

<19 Cs-134

<15

<15

<l5 Cs-137

<15

<15

<l5 Date Collected 4/26/82 8/30/82 12/27/82 Lab Code DSW-1191 DSW-2448 DSW-3711 Mn-54

<15

<15

<15 Co-58

<15

<15

<l5 Co-60

<15

<15

<15 Nb-95

<15

<15

<15 Zr-95

<15

<15

<15 Cs-134

<15

<15

<l5 Cs-137

<15

<15

<l5 O

~

74

. ~ -.

HAZLETON CNVIRONMENTAL SCENCE3 Table 36.

(continued)

Location Sample Description and Activity (pCi/1)

Plant Discharge Indicator D-51 Date Collected 1/29/82 5/24/82 9/27/82 Lab Code DSW-262 DSW-1431,2 DSW-2718 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<l5

<15

<l5 Nb-95

<15

<15

<15 Zr-95

<16

<15

<17 Cs-134

<15

<15

<15 Cs-137

<l5

<15

<15 j

Date Collected 2/22/82 6/30/82 10/26/82 Lab Code DSW-468 DSW-1777 DSW-3113 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<15

<15 i

Zr-95

<17

<15

<19 l

Cs-134

<15

<15

<15 l

Cs-137

<l5

<15

<15 Date Collected 3/29/82 7/27/82 11/29/82 Lab Code DSW-796,7 DSW-2174 DSW-3433,4 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<15

<15 Zr-95

<15

<18

<22 Cs-134

<l5

<15

<15 Cs-137

<15

<15

<15 Date Collected 4/26/82 8/30/82 12/27/82 Lab Code DSW-1192 DSW-2449 DSW-3712 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<15

<20 Zr-95

<15

<20

<30 Cs-134

<15

<15

<15 Cs-137

<15

<15

<15 O

75

Maya BTON ENVIRONMENTAL SCCNC ID Table 36.

(continued)

Location Sample Description and Activity (pCi/1)

Cedar Rapids City Park Indicator D-52 Date Collected 1/29/82 5/24/82 9/27/82 Lab Code DSW-263 DSW-1433 DSW-2719 Mn-54

<15

<l5

<15 i

Co-58

<l5

<l5

<15 i

Co-60

<l5

<15

<l5 I

Nb-95

<15

<15

<15 Zr-95

<19

<15

<15 Cs-134

<15

<15

<15 Cs-137

<l5

<15

<l5 Date Collected 2/22/82 6/30/82 10/26/82 Lab Code DSW-469 DSW-1778,9 DSW-3114 Mn-54

<15

<15

<15 Co-58

<l5

<15

<l5 Co-60

<l5

<l5

<l5

~ l5

<15

<15 Nb-95 i

Zr-95

<20

<l5

<25 Cs-134

<15

<l5

<l5 Cs-137

<l5

<l5

<l5 Date Collected 3/29/82 7/27'/82' 11/29/82 Lab Code DSW-798 DSW-2175 DSW-3435 Mn-54

<l5

<15

<l5 Co-58

<l5

<15

<l5 Co-60

<l5

<15

<15 Nb-95

<l5

<15

<l5 Zr-95

<18

<19

<23 Cs-134

<l5

<15

<15 i

Cs-137

<l5

<15

<15 l

Date Collected 4/26/82 8/30/82 12/27/82 i

Lab Code DSW-1193 DSW-2450 DSW-3713 Mn-54

<l5

<15

<l5 Co-58

<15

<15

<l5 Co-60

<15

<15

<l5 Nb-95

<15

<15

<18 Zr-95

<l5

<20

<21 i

Cs-134

<l5

<l5

<15 Cs-137

<l5

<15

<l5 l

'O 76 l

HAZLETON ENVIRONMENTAL SCENCEJ Table 36.

(continued)

Location Sample Description and Activity (pCi/1)

Farm Pond Control D-73 Date Collected 1/29/82 5/24/82 9/27/82 Lab Code DSW-264 DSW-1434 DSW-2720 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 4

Nb-95

<15

<15

<15 Zr-95

<15

<15

<15 Cs-134

<15

<15

<15 Cs-137

<15

<15

<15 Date Collected 2/22/82 6/30/82 10-27-82 Lab Code DSW-470 DSW-1780 DSW-3115 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<15

<15 Zr-95

<17

<15

<17 Cs-134

<15

<15

<15 O-Cs-137

<15

<15

<15 Date Collected 3/29/82 7/27/82 11/29/82 Lab Code DSW-799 DSW-2176 DSW-3436 i

Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

-<15

<15 Zr-95

<19

<15

<23 Cs-134

<15

<15

<15 Cs-137

<15

<15

<15 f

Date Collected 4/26/82 8/30/82 12/27/82 Lab Code DSW-1194 DSW-2451 DSW-3714 Mn-54

<15

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<15

<15 Zr-95

<15

<15

<15 Cs-134

<15

<15

<15 Cs-137

<15

<15

<15 l

l O

77

HAZLETON ENVIRCNMENTAL SCt!NCEJ Table 36.

(continued)

Location Sample Description and Activity (pCi/1)

Pleasant Creek Indicator D-99 Date Collected 1/29/82 5/24/82 9/27/82 Lab Code DSW-265 DSW-1435 DSW-2721 Mn-54

<l5

<15

<15 Co-58

<15

<15

<15 Co-60

<15

<15

<l5 Nb-95

<15

<15

<15 Zr-95

<21

<15

<15 Cs-134

<15

<l5

<15 Cs-137

<l5

<15

<l5 Date Collected 2/22/82 6/30/82 10/26/82 Lab Code DSW-471 DSW-1781 DSW-3116,7 Mn-54

<15

<15

<l5 Co-58

<l5

<l5

<15 Co-60

<l5

<15

<l5 l

Nb-95

<l5

<l5

<l5 Zr-95

<19

<15

<17 Cs-134

<l5

<l5

<l5 Cs-137

<15

<l5

<15 Date Collected 3/29/82 7/27/82 11/29/82 Lab Code DSW-800 DSW-2177 DSW-3437 Mn-54

<15

<l5

<15 Co-58

<l5

<15

<15 Co-60

<15

<15

<l5 l

Nb-95

<15

<l5

<15 l

Zr-95

<19

<l5

<23 I

Cs-134

<15

<15

<15 l

Cs-137

<l5

<l5

<15 Date Collected 4/26/82 8/30/82 12/27/82 Lab Code DSW-1195 DSW-2452,3 DSW-3715 Mn-54

<15

<l5

<l5 Co-58

<15

<15

<l5 Co-60

<l5

<15

<l5 Nb-95

<15

<l5

<l5 Zr-95

<19

<l5

<l5 Cs-134

<15

<15

<15 Cs-137

<l5

<15

<15 O

78 l

i.

HAZLETON ENVIRONMENTAL SCt:NCE3 Table 36.

(continued)

Location Sample Description and Activity (pC1/1)

Park Pond Indicator D-103 Date Collected 1/29/82 5/24/82 9/27/82 Lab Code DSW-266 DSW-1436 DSW-2722 Mn-54

<15

<15

<l5 Co-58

<l5

<l5

<l5 Co-60

<15

<15

<15 Nb-95

<15

<l5

<15 Zr-95

<l5

<15

<l5 Cs-134

<l5

<l5

<15 Cs-137

<15

<l5

<15 Date Collected 2/22/82 6/30/82 10/26/82 Lab Code DSW-472 DSW-1782 DSW-3118 Mn-54

<l5

<15

<15 Co-58

<15

<15

<l5 Co-60

<l5

<l5

<l5 Nb-95

<15

<15

<l5 Zr-95

<23

<15

<19 O

Cs-134

<15

<15

<l5 V

Cs-137

<l5

<15

<l5 Date Collected 3/29/82 7/27/82 11/29/82 Lab Code DSW-801 DSW-2178 DSW-3438 Mn-54

<15

<15

<15 Co-58

<l5

<15

<15 Co-60

<15

<15

<15 Nb-95

<15

<l5

<15 Zr-95

<l5

<15

<15 Cs-134

<15

<l5

<15 Cs-137

<15

<15

<15 Date Collected 4/26/82 8/30/82 12/27/82 Lab Code DSW-1196 DSW-2454 DSW-3716 Mn-54

<l5

<l5

<15 Co-58

<15

<15

<15 Co-60

<l5

<15

<15 Nb-95

<l5

<15

<15 l

Zr-95

<15

<l5

<15 Cs-134

<15

<l5

<15 Cs-137

<15

<15

<15 a ND = No Data. Sample could not be collected because the road was closed due to snow.

79

r HAZLETON ENVIRONMENTAL SCENCED Table 37.

Surface water samples, quarterly composites of monthly samples, analysis for gross beta, tritium, strontium-89, and strontium-90.

Activity (pCi/l) location and Lab Period Collected

Code, Gross Beta H-3 Sr-89 Sr-90 Indicator D-50 i

ist Q, 1982 DSW-860,1 5.9i0.5

<330

<l.1

<0.7 2nd Q, 1982 1828 4.0i0.7

<330

<1.6 0.8i0.6 3rd Q, 1982 2796 2.4i0.5

<330

<2.6

<0.9 4th Q, 1982 3783 3.2i0.8

<330

<1.5

<1.0 Annual Mean i s.d.

3.9tl.5

<330

<2.6 0.8i0.6 D-51 1st Q, 1982 DSW-862 4.7t0.7

<330

<1.1

<0.7 2nd Q, 1982 1829 3.8i0.7

<330

<l.4 1.1*0.5 3rd Q, 1982 2797 3.6i0.6

<330

<3.0

<1.0 4th Q, 1982 3784,5 3.2i0.5

<330

<1.5

<1.0 Annual Mean i s.d.

3.8i0.6

<330

<3.0 1.110.5 i

D-52 1st Q, 1982 OSW-863 4.2*0.7

<330

<1.1 0.6i0.4 2nd Q, 1982 1830 4;4 0.7

<330

<1.6

<1.2 3rd Q, 1982 2798 3.0i0.5

<330

<2.6

<0.9 4th Q, 1982 3786 2.9i0.7

<330

<1.3

<1.0 Annual Mean i s.d.

3.6i0.8

<330

<2.6 0.6i0.4 l

D-99 1st Q, 1982 DSW-864 7.7i0.8

<330

<l.8 1.8i0.7 2nd Q, 1982 1831 5.8i0.7

<330

<1.6 1.5i0.6 3rd Q, 1982 2799,2800 6.0i0.5

<330

<3.5 1.210.4 4th Q, 1982 3787 4.2i0.8

<330

<1.7

<0.9 Annual Mean i s.d.

5.9tl.4

<330

<3.5 1.Si0.3 Control D-49 1st Q, 1982 DSW-859 2.8i0.6

<330

<l.0 0.6i0.5 2nd Q, 1982 1827 3.8i0.7

<330

<l.5

<0.7 3rd Q, 1982 2795 2.7i0.5

<330

<2.5

<0.7 4th Q, 1982 3782 4.2i0.8

<330

<l.3

<0.8 Annual Mean t s.d.

3.4i0.7

<330

<2.5 0.6i0.5 80

HAZLETON ENVIRONMINTAL SCENCQ s

Table 38.

Fish samples, analysis of edible portion for gamma-emitting isotopes.

Collection: Serai-annually.

Sample Description and Activity (pCi/g wet)

Indicator Location D-61 D-61 0-61 Date Collected 5-26-82 5-26-82 11-17-82 Type River Carpsucker Carp River Carpsucker Lab Code DF-43,4 DF-45.

DF-135 K-40 3.55i0.31 2.95i0.41 3.81i0.47 Mn-54

<0.022

<0.045

<0.040 Co-58

<0.023

<0.047

<0.053 Co-60

<0.020

<0.036

<0.038 Nb-95

<0.037

<0.037

<0.085 Zr-95

<0.057

<0.073

<0.11 Ru-103

<0.067

<0.040

<0.081 Ru-106

<0.19

<0.26

<0.40 Cs-134

<0.029

<0.037

<0.040 Cs-137

<0.029

<0.029

<0.043 Ce-141

<0.054

<0.10

<0.18 n

Ce-144

<0.13

<0.23

<0.37 V

Location D-61 D-61 Date Collected 11-17-82 12-01-82 Type Carp Golden Redhorse Lab Code DF-136 DF-140 K-40 3.97i0.59 4.56i0.54 Mn-54

<0.042

<0.050 Co-58

<0.061

<0.072 Co-60

<0.058

<0.041 Nb-95

<0.083

<0.13 Zr-95

<0.097

<0.14 Ru-103

<0.077

<0.098 Ru-106

<0.38

<0.40 Cs-134

<0.034

<0.041 Cs-137

<0.042

<0.048 Ce-141

<0.11

<0.15 Ce-144

<0.25

<0.21 O

81

HAZLETON GNVIRONMENTAL SCENC'I3 O'

Table 38.

(continued)

Sample Description and Activity (pCi/g wet)

Control Location D-49 D-49 D-49 Date Collected 5-26-82 5-26-82 11-17-82 Type Quillback River Carpsucker River Carpsucker Lab Code DF-39 DF-40 DF-134 K-40 3.10i0.56 2.87i0.62 4.98i0.62 Mn-54

<0.037

<0.036

<0.054 Co-58

<0.051

<0.025

<0.077 Co-60

<0.048

<0.028

<0.059 Nb-95

<0.037

<0.034

<0.11 Zr-95

<0.13

<0.067

<0.14 Ru-103

<0.065

<0.033

<0.11 Ru-106

<0.48

<0.36

<0.52 Cs-134

<0.053

<0.039

<0.052 Cs-137

<0.045

<0.023

<0.061 Ce-141

<0.073

<0.064

<0.24 q

Ce-144

<0.33

<0.17

<0.52 l

V Location D-49 D-49 D-49 Date Collected 12-01-82 12-01-82 12-01-82 Type Bigmouth 8uffalo Carp River Carpsucker Lab Code DF-137 DF-138 DF-139 K-40 4.21i0.50 3.10i0.47 3.23i0.53 Mn-54

<0.047

<0.034

<0.045 Co-58

<0.068

<0.055

<0.078 Co-60

<0.042

<0.047

<0.050 Nb-95

<0.12

<0.093

<0.12 Zr-95

<0.13

<0.11

<0.17 Ru-103

<0.093

<0.089

<0.11 Ru-106

<0.41

<0.33

<0.37 Cs-134

<0.040

<0.032

<0.044 Cs-137

<0.043

<0.041

<0.043 4

Ce-141

<0.13

<0.12

<0.15 Ce-144

<0.20

<0.18

<0.23 O

U 82

HAZLETON CNVIRONMENTAL SClZNC~2 Table 39.

Periphyton samples, analysis for gamma-emitting isotopes.

Collection: Quarterly.

Sample Description and Activity (pCi/g wet)

Indicator Location D-61 D-61 Date Collected 3-9-82 5-27-82 Lab Code DB0-2 D80-7 K-40 4.03tl.60 4.14tl.50 Mn-54

<0.14

<0.16 Co-58

<0.17

<0.11 Co-60

<0.14

<0.17 Nb-95

<0.20

<0.10 Zr-95

<0.34

<0.25 Ru-103

<0.28

<0.091 Ru-106

<1.40

<l.35 Cs-134

<0.11

<l.11 Cs-137

<0.10

<0.15 Ce-141

<0.22

<0.16 C

<0.56

<0.65 O

e-144 Location D-61 0-61 Date Collected 8-19-82 11-18-82 Lab Code D80-13 080-17 K-40 4.28t2.20 9.31tl.73 Mn-54

<0.16

<0.22 Co-58

<0.12

<0.32 Co-60

<0.23

<0.22 Nb-95

<0.23

<0.40 Zr-95

<0.29

<0.54 Ru-103

<0.15

<0.37 Ru-106

<1.7

<l.92 Cs-134

<0.15

<0.21 Cs-137

<0.20

<0.23 Ce-141

<0.22

<0.80 Ce-144

<0.82

<l.84 O

83

MAZl.ETON ENVIRONMENTAL ECl2NCC Table 39.

(continued)

Sample Description and Activity (pCi/g wet)

Control Location D-49 D-49 Date Collected 3-9-82 5-27-82 Lab Code D80-1 080-6 K-40 1.87tl.30

<6.36 Mn-54

<0.10

<0.16 Co-58

<0.22

<0.26 Co-60

<0.11

<0.23 Nb-95

<0.14

<0.40 Zr-95

<0.37

<0.43 Ru-103

<0.22

<0.19 Ru-106

<1.29

<2.64 Cs-134

<0.16

<0.31 Cs-137

<0.096 0.69i0.24 Ce-141

<0.25

<0.37 Ce-144

<0.50

<1.44 Location D-49 D-49 Date Collected 8-19-82 11-18-82 i

Lab Code 080-12 080-16 K-40 3.91i2.20 6.11tl.35 Mn-54

<0.20

<0.20 Co-58

<0.13

<0.25 Co-60

<0.22

<0.18 Nb-95

<0.16

<0.35 Zr-95

<0.22

<0.47 Ru-103

<0.13

<0.30 Ru-106

<1.55

<l.64 Cs-134

<0.14

<0.16 Cs-137

<0.14

<0.19 Ce-141

<0.25

<0.63 Ce-144

<0.99

<1.47 l

l

' O 84 l

HAZLETON CNVIRONMENTAL SCl2NCOO Table 40.

River sediment samples, analysis for strontium-90 and gamma-emitting isotopes.

Collection: Semi-annually.

Sample Description and Activity (pCi/g dry)

Indicator Location D-50 0-50 Date Collected 5-27-82 11-18-82

(

Lab Code DBS-27 DBS-97 Sr-90 0.043i0.009

<0.012 K-40 12.27i0.77 10.80il.14 Mn-54

<0.053

<0.051 Co-58

<0.039

<0.060 Co-60

<0.036

<0.038 Nb-95

<0.051

<0.11 Zr-95

<0.053

<0.14 Ru-103

<0.070

<0.094 Ru-106

<0.28

<0.52 Cs-134

<0.047

<0.076 Cs-137 0.35i0.04

<0.052

<0.065

<0.13 O

Ce-141 Ce-144

<0.22

<0.26 Location D-51 0-51 Date Collected 5-27-82 11-18-82 Lab Code DBS-28 DBS-98 Sr-90

<0.021

<0.014 K-40 9.72 0.61 10.50il.14 Mn-54

<0.040

<0.052 Co-58

<0.039

<0.070 Co-60

. <0.036

<0.061 Nb-95

<0.039

<0.10 Zr-95

<0.071

<0.12 Ru-103

<0.054

<0.10 Ru-106

<0.28

<0.44 i

Cs-134

<0.036

<0.071 Cs-137

<0.039

<0.042 Ce-141

<0.070

<0.14 Ce-144

<0.17

<0.29 i

>O 85

MATI WTON GNVIRONMENTAL. CClZNCE~)

Table 40.

(continued)

Sample Description and Activity (pCi/g dry)

Indicator Location D-61 D-61 Date Collected 5-27-82 11-18-82

(

Lab Code DBS-29 DBS-99 Sr-90

<0.027

<0.016 K-40 8.81t0.55 9.78i0.46 Mn-54

<0.019

<0.033 Co-58

<0.025

<0.048 Co-60

<0.026

<0.037 Nb-95

<0.029

<0.072 Zr-95

<0.047

<0.094 Ru-103

<0.029

<0.084 Ru-106

<0.14

<0.39 Cs-134

<0.026

<0.053 Cs-137

<0.023

<0.037 Ce-141

<0.050

<0.092 C

<0.20

<0.21 O

e-144 Control Location D-49 D-49 Date Collacted 5-27-82 11-18-82 Lab Code DBS-26 DBS-96 Sr-90 0.009i0.006 0.008i0.007 K-40 9.80f0.60 9.79tl.06 Mn-54

<0.025

<0.055 Co-58

<0.025

<0.070 Co-60

<0.023

<0.050 Nb-95

<0.026

<0.079 Zr-95

<0.057

<0.11 Ru-103

<0.034

<0.098 Ru-106

<0.26

<0.047 Cs-134

<0.020

<0.080 Cs-137 0.09i0.02

<0.058 Ce-141

<0.056

<0.13 Ce-144

<0.13

<0.26 n

v 86

HAZLETON CNVIRONMZNTAL ECGNC2A Table 41.

Precipitation samples, analysis for gross beta and tritium.

Collection:

Monthly.

pCi/l Collection Date Lab Code Gross Beta H-3 1/82 DP-6 16.li3.1

<280 2/82 17 12.5tl.4

<280 3/82 27,8 2.2il.1

<280 4/82 46 2.9i0.5

<280 5/82 58 3.3i0.5

<280 6/82 75 ll.8i0.9

<280 7/82 90 2.li0.5

<280 8/82 101 1.9i0.6

<280 9/82 115 7.2i0.8

<280 10/82 131 3.li0.6

<280 11/82 143 9.8tl.1

<280 12/82 157 1.8i0.6

<280 Annual mean i s.d.

6.2i5.1

<280 O

4 O

87 a

HAZLETON UNVIRONMENTAL CCIENC2D O

i Appendix A Crosscheck Program Results O

l l

f i

O A-1

Hart NTON ENVIRONM3NTAL. SCl!NCOD Appendix A Crosscheck Program Results The Nuclear Sciences Department of Hazleton Environmental Sciences has parti-cipated in interlaboratory comparison (crosscheck) programs since the formula-tion of its quality control program in December 1971.

These programs are operated b agencies which supply environmental-type samples (e.g.,

milk or water) ycontaining concentrations of radionuclides known to the issuing agency but not to participant laboratories

'The purpose of such 4 program is to provide an independent check on the laboratory's analytical procedures and to alert it to any possible problems.

~~~

Participant laboratories measure the concentrations of specified radionuclides and report them to the issuing agency.

Several months later, the agency reports the known values to the participant laboratories and specifies control limits.

Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

The results in Table A-1 were obtained through participation in the environ-mental sample crosscheck program for milk and water samples during the period t,'

1975 through 1982.

This program has been conducted by the U. S. Environmental Protection Agency Intercomparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, Las Vegas, Nevada.

The results in Table A-2 were obtained for thermoluminescent dosimeters (TLD's) during the period 1976, 1977, 1979, 1980, and 1981 through participation in the Second, Third, Fourth, and Fifth International Intercomparison of Environmental Dosimeters under the sponsorships listed in Table A-2.

O e

O A-2

HA78 WTON GNVIR*JNM3NTAL SCI'_NC'23

()

Table A-1.

U.S. Environinental Protection Agency's crosscheck progran, comparison of EPA and Hazleton ES results for milk and water samples, 1975 through 1982a, Concentration in 3Ci/lb Lab Sample Date HES Result EPA lesult d

Code Type Coll.

Analysis i20 c i3a, n=1 r

STM-40 Milk Jan. 1975 Sr-89

<2 Oil 5 Sr-90 73t2.5 75*11.4 I-131 99i4.2 101*15.3 Cs-137 76i0.0 75i15 Ba-140

<3.7 0il5.0

' K(mg/1) 1470*5.6

  • 1510i228 STW-45 Water Apr. 1975 Cr-51

<14 0

Co-60 421i6 425163.9 Zn-65 487i6 497t74.7 Ru-106 505*16 497*74.7 Cs-134 385i3 400i60.0 Cs-137 468t3 450i67.5 l

STW-47 Water Jun. 1975 H-3 1459i144 1499i1002

(}

STW-48 Water Jun. 1975 H-3 2404i34 2204t1044 i

STW-49 Water Jun. 1975 Cr-51

<14 0

Co-60 344t1 350iS3 Zn-65 330i5 327i49 Ru-106 315i7 325i49 Cs-134 291i1 304i46 Cs-137 38 7i2 378i57 STW-53 Water Aug. 1975 H-3 3317i64 3200i1083 STW-54 Water Aug. 1975 Cr-51 223til 225t38 Co-60 305t1 307i46 Zn-65 289i3 281i42 Ru-106 346t5 279i57 l

l Cs-134 238t1 256t38 Cs-137 292i2 307i46 STW-58 Water Oct. 1975 H-3 1283i80 1203i988

! O l

l A-3

Havn NTON ENVIRONMZNTAL CCENC23 Table A-1.

(continued)

Concentration in )Ci/lb Lab Sample Date HE5 Result EPA lesult d

Code Type Coll.

Analysis i20 e i3a, n=1 STM-61 Milk Nov. 1975 Sr-90 68.9t2.1 74.6*11.2 I-131 64.6*3.8 75t15 Cs-137 75.6i20 75i15 Ba-140

<3.7 0

K(Mg/l) 1435i57 1549i235

.STW-63 Water Dec. 1975 H-3 1034i39 1002*972 STW-64 Water Dec. 1975 Cr-51

<14 0

Co-60 221t1 203*30.5 Zn-65 215i6 201i30.2 Ru-106 171i9 181i27.2 Cs-134 198i2 202*30.3 Cs-137 152i4 151*22.7 STW-68 Water Feb. 1976 H-3 1124i31 1080i978 O

STW-78 Water Jun. 1976 H-3 2500t44 2502*1056 STW-84 Water Aug. 1976

~H-3 3097t21 3100i1080 STM-91 Milk Nov. 1976 I-131 83i0.6 85t15 Ba-140

<4 0

Cs-137 12*1.7 11i15 K(mg/1) 1443t31 1510*228 STW-93 Water Dec. 1976 Cr-51 105t15 104t15 Co-60

<4 0

Zn-65 97i4 102il5 Ru-106 87*3 99i15 Cs-134 85i4 93t15 i

l Cs-137 103i4 101t15 STW-94 Water Dec. 1976 H-3 2537 15 2300i1049 STM-97 Milk Mar. 1977 I-131 55i2.5 51i15 l

Ba-140

<6 0

Cs-137 34t1 29t15 K(mg/1) 1520i35 1550i233 STW-101 Water Apr. 1977 H-3 1690i62 1760i1023 A-4

HA71 NTON CNVIRONMENTAL CCCNCE]

Table A-1.

(continued)

Concentration in )Ci/lb Lab Sample Date HES Result EPA lesult d

Code Type Coll.

Analysis t2a e f3a, n=1 STM-130 Milk May 1977 Sr-89 38i2.6 44*15 Sr-90 12i2.1 10i4.5

)

I-131 59i2.1 50il5 Ba-140 53i4.4 72*15 Cs-137 14tl.2 10il5 K(mg/l) 1533i21 1560i234 STW-105 Water Jun. 1977 Cr-51

<14 0

Co-60 29t1 29 15 Zn-65 74i7 74t15 Ru-106 64t8 62*15 Cs-134 41t1 44t15 s

Cs-137 35*3 35*15 s

STW-107 Water Jun. 1977 Ra-226 4.7i0.3 5.li2.42 s

STW-113 Water Aug. 1977 Sr-89 13t0e 14t15 Sr-90 10i2e 10i4.5 STW-116 Water Sep.1977 Gross Alpha 1216 10t15 s

Gross Beta 32i6 30il5 STW-118 Water Oct.,1977 H-3 1475i29 1650i1017 STW-119 Water Oct. 1977 Cr-51 132i14 153t24 Co-60 39t2 38t15 Zn-65 51i5 53i15 Ru-106 63i6 74i15 Cs-134 30i3 30il5 Cs-137 26i1 25 15 l

STW-136 Water Feb. 1978 H-3 1690i270 1680i1020 STW-137 Water Feb. 1978 Cr-51

<27 0

Co-60 36*2 34*15 Zn-65 32i4 29*15 Ru-106 41i2 36t15 Cs-134 47i2 52*15 Cs-137

<2 0

O A-5 g

wy-w

HAZLETON CNVIRONMENTAL SCCNCED O

Table A-1.

(continued)

Concentration in 2Ci/lb t3a,n=1glt EPA les Lab Sample Date HE5 Result Code Type Coll.

Analysis

  • 2a c 5.4ip.1 5.5i0.6 STW-138g Water Mar. 1978 Ra-226 Ra-228 NA 16.7i2.5 STW-150 Water Apr. 1978 H-3 2150t220 2220t1047 STW-151 Water Apr. 1978 Gross Alpha 20i1 20il5 Gross Beta 56i4 59t15 r

Sr-89 1912 21t15 Sr-90 8t1 10i4c5 Co-60 19i3 20il5 Cs-134 16t1 15i15 Cs-137

<2 0

s STM-152 Milk Apr.1978 Sr-89 85i4 101i15 l

Sr-90 8il 9i4.5 I-131 78t1 82il5 Cs-137 29*3 23t15 Ba-140

<11 0

K(mg/1) 1503i90 1500i225 STW-154g Water May 1978 Gross Alpha 12i1 13t15 Gross Beta 21i4 18t15 3.7i0.6 STW-1579 Water Jun. 1978 Ra-226 4.0i}.0 Ra-228 NA 5.6i0.8 STW-159g Water Jul. 1978 Gross Alpha 19*3 22i6 Gross Beta 28i3 30t5 STW-162 Water Aug. 1978 H-3 1167i38 1230i990 STW-165g Water Sep. 1978 Gross Alpha 4t1 5t5 Gross Beta 13i1 10i5 O

A-6

d HAZLETON ENVIRINMENTAL CCCNCES l

Table A-1.

(continued)

Concentration-in )Ci/lb Lab Sample Date HE5 Result EPA lesult Code Type Coll.

Analysis i2a e i3 a, n=1d STW-167 Water Oct. 1978 Gross Alpha 19i2 19i15 Gross Beta 36i2 34i15 Sr-89 9tl 10il5 Sr-90 4i0 Si2.4 Ra-226 5.Si0.3 5.0i2.4 Ra-228 NAf 5.4i2.4 Cs-134 1011 10il5 Cs-137 15t1 13i15 STW-170 Water Dec. 1978 Ra-226 11.5i0.6 9.2il.4 Ra-228 NAf 8.914.5 STW-172 Water Jan. 1979 Sr-89 11*2 14*15 Sr-90 5t2 6i4.5 STW-175 Water Feb. 1979 H-3 1344t115 1280i993 O

STW-176 Water Feb. 1979 Cr-51

<22 0

Co-60 10i2 9t15

'Zn-65 26i5 21 15 Rn-106

<16 0

Cs-134 8i2 6t15 Cs-137 15i2 12t15 STW-178 Water Mar. 1979 Gross Alpha 6.3i3 10il5 Gross Beta 1514 16*15 STW-195g Water Aug. 1979 Gross Alpha 6.3tl.2 Si5 Gross Beta 42.7i7.0 40i4 STW-193 Water Sep. 1979 Sr-89 5.0*1.2 3.0*1.5 Sr-90 25.0i2.7 28.0i4.5 STW-196 Water Oct. 1979 Cr-51 135i5.0 113i18 Co-60 7.0il.0 6i5 Cs-134 7.3i0.6 7t15 Cs-137 12.7tl.2 11t15 STW-198 Water Oct. 1979 H-3 1710i140 1560i1111 0

A-7

Mays NTON ENVIRONMZNTAI. SCl2NC3]

O Table A-1.

(continued)

Concentration in aci/lb Lab Sample Date HES Result EPA lesult Code Type Coll.

Analysis

  • 2a c i3a, n=1d STW-199 Water Oct. 1979 Gross Alpha 16.0t3.6 21*15 Gross Beta 36.3*1.2 49i15 Sr-89 10.7*0.6 12*15 Sr-90 5.7*0.6 7*15 Ra-226 11.110.3 11i5 Ra-228 1.610.7 0

Co-60 35.0il.0 33i15 Cs-134 50.7i2.3 56t15 Cs-137

<3 0

STW-206 Water Jan. 1980 Gross Alpha 19.0i2.0 30.0t8.0 Gross Beta 48.0i2.0 45.0i5.0 STW-208 Water Jan. 1980 Sr-89 6.1tl.2 10.0i0.5 l

Sr-90 23.9tl.1 25.5*1.5 t

STW-209 Water Feb. 1980 Cr-51 112i14 101i5.0 Co-60 12.7i2.3 11i5.0 Zn-65 29.7i2.3 25i5.0 Ru-106 71.7tl.5 51i5 Cs-134 12.0t2.0 10i5.0 l

Cs-137 30.0i2.7 3015.0 STW-210 Water Feb. 1980 H-3 1800il20 1750t340 STW-211 Water March 1980 Ra-226 15.7i0.2 16.0i2.4 Ra-228 3.Si0.3 2.6i0.4 l

STM-217 Milk May 1980 Sr-89 4.4i2.69 Si5 Sr-90 10.0tl.0 12il.5 STW-221 Water June 1980 Ra-226 2.0i0.0 1.7i0.8 t

Ra-228 1.6i0.1 1.7i0.8 l

l O

j A-8 l

HAZLET.')N ENVIRONMENTAL CCCNCEJ O

Table A-1.

(continued)

Concentration in 1Ci/lb Lab Sample Date HES Result EPA lesult d

Code Type Coll.

Analysis i2o C i3a, n=1 STW-223 Water July 1980 Gross Alpha 31i3.0 38i5.0 Gross Beta 44i4 35i5.0 STW-224 Water July 1980 Cs-137 33.910.4 35i5.0 Ba-140

<12 0

K-40 1350i60 1550i78 I-131

<5.0 0

STW-225 Water Aug. 1980 H-3 1280 ISO 1210i329 STW-226 Water Sept. 1980 Sr-89 22il.2 24i8.6 Sr-90 1210.6 15i2.6 STW-228 Water Sept. 1980 Gross Alpha NAf 32.0i8.0 Gross Beta 22.Si0.0 21.0i5.0 STW-235 Water Dec. 1980 H-3 2420i30 2240i604 STW-237 Water Jan. 1981 Sr-89 13.0tl.0 16i8.7 Sr-90 24.0i0.6 34i2.9 STM-239 Milk Jan. 1981 Sr-89

<210 0

Sr-90 15.7i2.6 20i3.0 l

I-131 30.9i4.8 26i10.0 Cs-137 46.912.9 43t9.0 Ba-140

<21 0

K-40 1330iS3 1550i134 STW-240 Water Jan. 1981 Gross alpha 7.3i2.0 9i5.0 Gross beta 41.0i3.1 44t5.0 STW-243 Water Mar. 1981 Ra-226 3.Si0.06 3.4i0.5 Ra-228 6.Si2.3 7.3*1.1 l

l I

A-9 l

HAZLETON ENVIRINMZNTAL CCENC""3 OU Table A-1.

(continued)

Concentration in 3Ci/lb Lab Sample Date HES Result EPA Result Code Type Coll.

Analysts

  • 2a e i3a, n=ld STW-245 Water Apr. 1981 H-3 3210*115 2710i355 STW-249 Water May 1981 Sr-89 51i3.6 3618.7 Sr-90 22.7i0.6 2212.6 STW-251 Water May 1981 Gross alpha 24.0i5.29 21i5.25 Gross beta 16.111.9 14i5.0 STM-252 Water Jun. 1981 H-3 2140i95 1950iS96 STW-255 Water Jul. 1981 Gross alpha 20il.5 22 9.5 Gross beta 13.0i2.0

,15i8.7 STW-259 Water Sep. 1981 Sr-89 16.1*1.0 23i5 Sr-90 10.3i0.9 11tl.5 p

STW-265 Water Oct. 1981 Gross alpha 71.2i19.1 80i20 V

Gross beta 123.3i16.6 111i5.6 Sr-89 14.9i2.0 21i5 Sr-90 13.1*1.7 14.4tl.5 Ra-226 13.0i2.0 12.7tl.9 -

STW-269 Water Dec. 1981 H-3 2516i181 2700i355 STW-270 Water Jan. 1982 Sr-89 24.3i2.0 21.0i5.0 l

Sr-90 9.4t0.5 12.0il.5 STW-273 Water Jan. 1982 I-131' 8.6t0.6 8.4tl.5 STW-275 Water Feb. 1982 H-3 1580t147 1820t342 STW-276 Water Feb. 1982 Cr-51

<61 0

Co-60 26.0i3.7 20i5 Zn-65

<13 15i5 Ru-106

<46 20i5 Cs-134 26.8i0.7 2215 Cs-137 29.7tl.4 23i5 STW-277 Water Mar. 1982 Ra-226 11.9tl.9 11.6tl.7

~

STW-278 Water Mar. 1982 Gross alpha 15.6tl.9 19i5 Gross beta 19.2i0.4 19i5 l

l l

A-10

MAZLETON GNVIRONMZNTAL CCIZNCOO O'

Table A-1.

(continued)

Concentration in )C1/lb Lab Sample Date HES Result EPA tes It Code Type Coll.

Analysis

  • 2a e i30, n=1 STW-280 Water Apr. 1982 H-3 2690i80 2860i360 STW-281 Water Apr. 1982 Gross alpha 75i7.9 85*21 Gross beta 114.li5.9 106i5.3 Sr-89 17.4tl.8 24*5 Sr-90 10.5i0.6 12 1.5 Ra-226 11.4*2.0 10.9tl.5 Co-60

<4.6 0

STW-284 Water May 1982 Gross alpha 31.5i6.5 27.Si7 Gross beta 25.9t3.4 29i5 STW-285 Water June 1982 H-3 1970i1408 1830i340 STW-286 Water June 1982 Ra-226 12.6*1.5 13.4i3.5 Ra-228 11.li2.5 8.7i2.3 STW-287 Water June 1982 I-131 6.Si0.3 4.4i0.7 STW-290 Water Aug. 1982 H-3 3210i140 2890i619 STW-291 Water Aug. 1982 I-131 94.6i2.5 87t15 STW-292 Water Sept 1982 Sr-89 22.7i3.8 24.Si8.7 Sr-90 10.9i0.3 14.Si2.6 STW-296 Water Oct. 1982 Co-60 20.0il.0 20i8.7 l

Zn-65 32.315.1 24t8.7 Cs-134 15.3tl.5 19.0i8.7 Cs-137 21.0il.7 20.0i8.7 STW-297 Water Oct. 1982 H-3 2470t20 2560i612 STW-298 Water Oct. 1982 Gross alpha 32i30 55i24 Gross beta 81.7i6.1 81i8.7 Sr-89

<2 0

Sr-90 14.li0.9 17.2i2.6 Cs-134

<2 1.8i8.7 l

i Cs-137 22.7i0.6 20i8.7 Ra-226 13.6i0.3 12.5i3.2 Ra-228 B.9tl.0 3.6i0.9 O

A-11

i Ha78 UON CNVIRONM2NTAL ECl2NCE'3

O Table A-1.

(continued)

Concentration.in >Ci/lb Lab Sample Date HES Result EPA lesylt Code Type Coll.

Analysis

  • 2a C i3a, n=18 STW-301 Water Nov. 1982 Gross alpha 12.0il.0 19.0i8.7 I

Gross beta 34.0*2.7 24.0i8.7 J

STW-302 Water Dec. 1982 I-131 40.0t0.0 37.0*10 1

aResults obtained by the Nuclear Sciences Department of Hazleton Environ-mental Sciences as a participant in the environmental sample crosscheck program operated by the Intercomparison and Calibration Section, Quality Assurance Branch, Environmental Monitoring and Support Laboratory, U.S.

Environme.ntal Protection Agency, (EPA), Las Vegas, Nevada.

ball results are in pCi/1, except for elemental potassium (K) data which are in mg/1.

cUnless otherwise indicated, the HES results given as the mean *2a standard deviations for three determinations, duSEPA results are presented as the known values i control limits of 3a for n=1.

eMean i 2a standard deviations of two determinations.

fNA = Not analyzed.

9 Analyzed but not reported to the EPA.

I O

A-12

O O

O Table A-2.

Crosscheck program results, thermoluminescent dosimeters (TLD's).

mR d

Hazleton Average 12o Lab TLD Result Known (all Code Type Measurement i2 o a Value participants) b 2nd International Intercomparison 115-2b CaF :Mn Gamma-Field 17.011.9 17.lc 16.417.7 2

Bulb

+

~

Gamma-Lab 20.814.1 21.3c 18.8i7.6 y

3rd International Intercomparisone f

CaF :Mn Gamma-Field 30.7i?.2 34.914.8f 31.5i3.0 115-3e 2

Bulb a

y Gamma-Lab 89.6i6.4 91.7114.6f 86.2i24.0 0

4th International Intercomparison9 h

CaF :Mn Gamma-Field 14.111.1 14.lil.4f 16.09.0 115-49 2

Bulb r-Gamma-Lab (Low) 9.3fl.3 12.2i2.4f 12.017.6 mOl Gamma-Lab (High) 40.411.4 45.819.2f 43.9113.2 5th International Intercomparisonh Qm 115-5Ah CaF :Mn Gamma-Field 31.4tl.8 30.016.01 2

30.2i14.6 Gamma-Lab 77.4i5.8 75.217.6I 75.8i40.4 at beginning Gamma-Lab 96.6i5.8 88.418.81 90.7i31.2 at the end

O O

O Table A-2.

(Continued) mR d

Hazleton Average i 20 Lab TLD Result Known (all Code Type Measurement 12aa Value participants) 115-5Bh LiF-100 Gamma-Field 30.314.8 30.016i 30.2114.6 I

Chips i

Gamma-Lab 81.lt7.4 75.2i7.61 75.8i40.4 l

at beginning Gamma-Lab 85.4i11.7 88.418.8I 90.7i131.2 O

l at the end Z<

alab result given is the mean 120 standard deviations of three determinations.

5 O

bSecond International Intercomparison of Environmental Dosimeters conducted in April of 1976 by the Health l

}-

2 and Safety Laboratory (GASL), New York, New York, and the School of Public Health of the University of i

l Texas, Houston, Texas.

cValue determined by sponsor of the intercomparison using continuously operated pressurized ion chamber.

dMean 120 standard deviations of results obtained by all laboratories participating in the program.

eThird International Intercomparison of Environmental Dosimeters conducted in summer of 1977 by Oak Ridge National Laboratory and the School of Public Health of the University of Texas, Houston, Texas.

g f alue 120 standard deviations as determined by sponsor of the intercomparison using continuously operated Q

V R

pressurized ion chamber.

9 Fourth International Intercomparison of Environmental Dosimeters conducted in summer of 1979 by the l

School of Public Health of the University of Texas, Houston, Texas.

m8 hFifth International Intercomparison of Environmental Dosimeter conducted in fall of 1980 at Idaho Falls, Idaho and sponsored by the School of Public Health of the University of Texas, Houston, Texas and Environmental Measurements Laboratory, New York, New York, U.S. Department of Energy.

+

IValue determined by sponsor of the intercomparison using continuously operated pressurized ion chamber.

4

HAMON ENVIRONMENTAL SCIENCES O

Appendix 8 Data Reporting Conventions t

O 8-1

HAZLETON ENVIRONMENTAL SCIENCES l

(

Data Reporting Conventions 1.0.

All activities are decay corrected to collection time.

2.0.

Single Measurements Each single measurement is reported as follows:

xis where x = value of the measurement; s=2 counting uncertainty (corresponding to the 95% confidence level.).

In cases where the activity is found to be below the lower limit of detection L it is reported as

<L.

where L = is the lower limit of detection based on 4.66o uncertainty for a background sample.

3.0.

Duplicate Analyses 3.1.

Individual results: x1 i s1 x2 i s2 Reported result:

xis where x = (1/2) (x1 + x2) 2+s2 s = (1/2) s 3.2.

Individual results: <L1 l

<L2 Reported result:

<L

~

~

where L = lower of L1 and L2 3.3.

Individual results: xis

<L Reported result:

x i s if x < L;

<L otherwise o

B-2 1

L

HAZLETON ENVIRONMENTAL SCIENCES

's

\\

4.0.

Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviations of a set of n numbers x1, x2, Xn are defined as follows:

x=fIx II*-*)2

)

s=

n-1 4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all of the values in the averaging group are less than the highest LLD, the highest LLD is reported.

(m 4.4 If all but one of the values are less than the highest LLD. the

(,)

single value x and associated two sigma error is reported.

4.5. In rounding off, the following rules are followed:

4.5.1. If the figure following those to be retained is less than 5, the figure is dropped, and the retained figures are kept unchanged. As an example,11.443 is rounded off to 11.44.

4.5.2 If the figure following those to be retained is greater than j

5, the figure is dropped, and the last retained figure is raised by 1.

As an example, 11.446 is rounded off to 11.45.

4.5.3. If the figure following those-to be retained is 5, and if there are no figures other than zeros beyond the five, the figure 5 is dropped, and the last-place figure retained is increased by one if it is an odd number or it is kept l

unchanged if an even number. As an example,11.435 is rounded off to 11.44, while 11.425 is rounded off to 11.42.

B-3 l

l