SEMI-ANNUAL REPORT Radioactive Effluent Releases January 1,1982 through June 30, 1982 i
i l
f
(
?
i l
I I
l i
l l
i i
r s
l 8209000379 820827 l
R t
i i
RADIATION EFFLUENT REPORT January 1, 1982 through June 30, 1982 ITEM UNITS IST QUARTER 1982 2ND QUARTER 1982 A. Gaseous Effluents
- 1. Gross Radioactivity' curies 2.25 El 2.07 El
- 2. Maximum I hour Release Rate pCi/sec 2.57 El 2.37 El
- 3. Nuclides Released Xe-138 curies 4.74 E0 1.02 El Kr-87 curies 7.40 E-2 5.00 E-3 Kr-88 curies 2.01 E-1 3.40 E-1 O
Kr-85m curies 3.34 E-1 2.51 E-1 Xe-135 curies 8.20 EO 5.26 EO Xe-133 curies 4.89 E0 2.22 E0 Kr-85(cal.)
curies
<2.4 E-2
<1.2 E-2 Xe-1.35m curies 3.78 E0 2.08 EO Ar-41 curies 1.01 E-1 7.10 E-2 N-13 curies 1.59 E-1 3.17 E-1
- 5. Percent of ETS 0.074 0.031 (16% of Limit)
-**e+%ep,=,.-e--w
- ~ =..
.m.-.%
-,g.i
-g,
,. y~
e.w-w.,
w ws9 ep
RADIATION EFFLUENT REPORT January 1, 1982 through June 30, 1982 ITEM p.,.., UNITS IST QUARTER 1982 2ND QUARTER 1982 B. Iodine Releases
- 1. Total I-131 Released curies 3.46 E-3 1.35 E-3
- 2. Tota,1 1-133 Released curies 4.87 E-3 1.58 E-3
- 3. Total I-135 Released curies 5.64 E-3 1.13 E-3
0.26 %
C. Particulate Releases
, O
- 1. Total Released curies 2.19 E-3 9.24 E-4 i
- 2. Gross Alpha Released curies 8.27 E-6 2.76 E-5
- 3. Nuclides Released Ba-140 curies 1.58 E-4 4.78 E-5 Cs-138 curies 9.22 E-4 5.98 E-4 Co-60 curies 9.65 E-5 2.72 E-5 Mn-54 curies 2.00 E-5 1.86 E-6 l
Cs-137 curies 3.50 E-6 None Rb-89 curies 4.87 E-6 None K-40 curies 2.91 E-5 None
RADIATION EFFLUENT REPORT January 1, 1982 through June 30, 1982 ITEM UNITS IST QUARTER 1982 2ND QUARTER 1982 Co-58 curies 2.41 E-6 None Cr-51 curies None 1.79 E-5 Bi-214 curies None 6.24 E-5 Nb-95 curies None 8.40 E Sr-89 curies 6.53 E-5 1.65 E-5 Sr-90 curies 4.54 E-6 2.71 E-6 Unidentified curies 8.8 E-4 1.49 E-4
- 4. Percent ETS Limit (Part.) Note 3 1.52 %
.62 %
0.89 %
l O
NOTE 1 QSE Q
+
5 y
0.21 (1.4 X 10 )(MPC)
% ETS
=
X 100 l
0.16
)
l NOTE 2 QS Q
+
1.3 X 10-6 1.8 X 10 -7
%ETS(I-131)
=
X 100 0.08 NOTE 3 l
+
l 1.3 X 10-6 1.8 X 10 -7 ETS(PART)
=
X 100 0.08 NOTE 4 P
QS Q
l
+
1.3 X 10-6 1.8 X 10 -7 ETS(PaI-131)
=
X 100 l
0.08 O
r 1
- O LIQUID EFFLUENT 5 l
No Liquid Releases January 1,1982 through June 30, 1982 O
SOLID RADI0 ACTIVE WASTE January 1,1982 through June 30, 1982
~
O o te veie e<<t )
^ctivitu <ci) trae er w ste 1/8/82 85 25.3 Solidified Resin 1/12/82 85 13.5 Solidified Resin 1/14/82 85 33.75 Solidified Resin 1/19/82 180
.3528 Trash 1/20/82 85 6.75 Solidified Resin 1/27/82 85 6.0 Solidified Resin 1/27/82 562.5
.2709 Trash 1/29/82 85 12.0 Solidified Resin 2/2/82 85 30.0 Solidified Resin 2/4/82 85 23.9 Solidified Resin 2/8/82 85 15.7 Solidified Resin 2/17/82 85 9.9 Solidified Resin 2/19/82 85 57.4 Solidified Resin 2/22/82 85 50.8 Solidified Resin D
2/24/82 472.5
.2418 Trash O
3/1/82 85 3.88 Sei484ried aesie 3/3/82 85 5.174 Solidified Resin 3/5/82 85 4.39 Solidified Resin 3/8/82 85 2.576 Solidified Resin 3/10/82 85 5.815 Solidified Resin 3/12/82 85 9.454 Solidified Resin 3/15/82 85 6.061 Solidified Resin 3/17/82 85 4.921 Solidified Resin 3/19/82 85 2.210 Solidified Resin 3/24/82 85 2.711 Solidified Resin 3/26/82 85 2.743 Solidified Resin 3/29/82 165
.1014 Trash 3/31/82 85 24.1 Solidified Resin l
4/7/82 85 4.487 Solidified Resin 4/12/82 85 3.792 Solidified Resin 4/15/82 85 8.165 Solidified Resin lp 4/19/82 85 6.824 Solidified Resin V
4/21/82 85 46.94 Solidified Resin
SOLID RADI0 ACTIVE WASTE January 1,1982 through June 30, 1982 Date Volume (ft )_
Activity (Ci)
Type of Waste 3
4/23/82 85 16.88 Solidified Resin 4/27/82 442.5
.2688' Trash 4/30/82 85 21.96 Solidified Resin 23.0 Solidified Resin 5/3/82 85 5/5/82 85 20.5 Solidified Resin 5/7/82 85 18.27 Solidified Resin 5/12/82 85 2.972 Solidified Resin 5/18/82 85 25.0 Solidified Resin 5/20/82 85
.3.69 Solidified Resin
~
5/24/82 85 47.22 Solidified Resin 5/25/82 532.5
.2904 Trash 5/26/82 85 2.487 Solidified Resin 6/3/82 85 9.570 Solidified Resin 6/7/82 85 2.63 Solidified Resin 6/11/82 85 3.808 Solidified Resin 6.451 Solidified Resin
)
6/14/82 85 6/16/82 85 3.278 Solidified Resin 6/18/82 85 16.2 Solidified Resin 6/23/82 247.5
.215 Trash 6/25/82 85 4.63 Solidified Resin 6/28/82 85 12.9 Solidified Resin All shipments sent to Barnwell, Sath Carolina.
Compacted Trash 2602.5 F3 1.7411 curies Solidified Resin 4080.0 F3 674.471 curies I
t TOTAL 6682.5 F3 676.2121 curies e
m
-