. LICENSEE EVENT REPORT

'e CONTROL BLOCX: l l l l l l lh (PLEASE PRINT OR TYPE ALL REQU' RED INFORMATION1

-i o i 8 9 l M l LICENSEE

! l D lCODE C l C l 2 l@l 14 15 0 l 0 l 0LICENSE l 010NuMtsEH l0 l0 l0 l0 l0 l0 l@l4 2'a 26 l1 l1 l1 LICENSE TYPEl1J0l@l57 l LAT$8 l@

CON'T lolil

' 8 EUs I60 L l@l 0151010101311 61 DOCKET NUMBER l 686 l@l01110 69 l8 l 812 l@lo REPORT EVENT DATE 74 75 li l2 DATE li la l980l@

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES O'o 10 l21 lWHILE REVIEWING TEST PROCEDURES, IT WAS DISCOVERED THAT THE ESSENTIAL SERVICE WATER l o .i l(ESW) VALVES WM0-734 AND -738 WERE NOT TESTED AS REQUIRED BY T.S.4.7.4.1.8 (EV IO i ; l1735). THIS RENDERED BOTH ESW LOOPS IN0PERABLE PER T.S. 3.7.4.1. A POWER REDUCTION l ioisi lWAS STARTED AT 1825 HOURS ON 01-08-82 AS REQUIRED BY TECHNICAL SPECIFICATION PARAGRAPH; I O is 1 I 3 .0.3. THE ESW LOOPS WERE DECLARED OPERABLE AND THE POWER REDUCTION WAS TERMINATED l l 0 l, g lWHEi, WM0-734 (EAST LOOP) WAS SATISFACTORILY TESTED ON 01-08-82. WM0-734 WAS TESTED AT, io,ai[1837 HOURS AND WM0-738 AT 1847 HOURS. l DE CODE S BCO E COMPONENT CODE SUSC DE SU E 10191 1 8 l Wl Bl@ l Bl@ lZ l@ l Zl Zl Zl Zl Zl Zl@ W@ l z l@

9 10 11 12 13 18 19 20 L EVENT YEAR REP RT O CODE Y N

@ ,a=E R RO la l2 l l-l I o f o f 21 l-l l 01 11 lTl l-1 10l

_ 21 22 23 24 26 27 28 29 30 31 32 AKEN AC r ON PL NT ME HOURS 22 S8 IT O FOH b 8. SU LI R MAN FACTURER LG_j@[ Z_j@ lZl@ l36Z l@' l 0 10 l 0 l 0 l []N_j @ lN l@ [Z__J@ lZ l 9l 9l 9l@

33 34 35 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h litoilINVESTIGATION REVEALED THAT THE ESW VALVES, WM0-734 AND -738 WERE OMITTED DURING A l lii_y l PROCEDURE REVISION IN OCTOBER 1979. THE PROCEDURE WAS ALSO REVISED IN APRIL 1981 AND l i,i,i lTHE ESW VALVES WERE AGAIN NOT INCLUDED IN THE TEST PROCEDURE AS THE OCTOBER 1979 RE- l i1 i3i l VISION WAS USED AS A REFERENCE. THE TESTING 0F VALVES WM0-734 AND -738 WAS AD g lTHE APPROPRIATE PROCEDURES AND TESTED ON 01-08-82. l T S %POWEh OTHER STATUS dis O RY DISCOVERY DESCRIPTION 32 NA l 1115 I lE l@ l 1 l 010 l@l l l C l@l DURING REVIEW 0F T.S. SURVEILLANCES ACTIVITY CO TENT 54ELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELE ASE NA I1I6l [Z_j @ [Z_J @ l NA l l 80 l

! 8 9 10 11 44 45 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION NA l I 1 I 7 l l0 l 0 l 0 l@[Z_J@l

' " ' ,ERSONNa',Na2iES '

NuMeE R DESCniPTiO~@

[i la l l010 l0 l@' NA l OSS ypE DESC PT N O O f6 y W@l NA PDR l 80 1 N 9 10 ISSU l1L2]8 3[3]E @ l DESCRIPTION NA -l Illllll1lllll$

/ 10 68 69 80 5 NAME OF PREPARER R. A. PALMER psoys i616-465-5901

. . _ _ _ _ _