LER 81-057/03L-0:on 811123,bypass Valves Found in Open Position During Normal Operation While Performing Check of Valve Lineup for 1R-11/12 Containment Radiation Monitor Sys. Cause Not Determined.Caution Tag Placed on Valves
ML20039C854
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 12/23/1981
From: Palmer R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20039C853 List:
References
LER-81-057-03L-01, LER-81-57-3L-1, NUDOCS 8112310008
Download: ML20039C854 (1)


Text

- . . . . . . _ . . . . . . . . . .. _ .__....

+ LICENSEE EVENT REPORT lh CONTROL BLOCK: l l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI i e

[o W8 l9 M l ILICENSEE 1

lDlC CODE l C l 14l' l@l 15 01010 l 0 LICENSE10 10NUMBEH 10 l 0l 0l 01 Ol@l 23 26 4l llLICENSE 1 l~ 11 TYPE11@lJu l

57 CAT 58 l@

CON'T lolil I 8 S uRCE ll60 l@l015101010 61 l311 15 l@ll DOCKET NUMBER 68 69 11 121318 EVENT DATE l1 l@l1 12121318 14 75 REPORT DATE 1180l@.

EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h 10 l 21 l DURING NORMAL OPERATION, A CHECK OF THE VALVE LINE-UP FOR 1R-ll/12 CONTAINMENT RADIA- 1 iO i3i l TION MONITOR SYSTEM WAS PERFORMED. AT THIS TIME IT WAS NOTED THAT THE BYPASS l VAL IO pllWERE IN THE OPEN POSITION, THE BYPASS VALVES WERE IMMEDIATELY RETURNED TO THE CLOSED l 1Ol5l l POSITION. THIS CONDITION WAS NONCONSERVATIVE WITH RESPECT TO TECHNICAL SPECIFICATIONS l 10 ls l l3.3.3.1 AND 3.4.6.1. THIS WAS THE FIRST OCCURRENCE OF THIS TYPE. l 10 l 7 l l l I

10 6 81 l

  • $DE C C0$E SUBC DE COVPONENT CODE SUS DE S E lOI91 l B l B l@ [A_l@ [X_j @ l I I N l S l T l R l U lh [_X_j@ [Z__j @

J 8 9 10 11 12 13 18 19 20

_ SECUENTIAL OCCURRENCE REPORT REVISION LER EVENT YEAR REPORT NO. CODE TYPE NO.

@,aggRO, I 81 il

,_ 21 22 1-1 23 I of si 7l 24 26 W

21 10131 28 29 IL l JG l-l 31 l0_j 32 KEN A N ONP NT ME HOURS 22 $8 IT FO 8. SU PL1 MAN FA URER

[.E__j@l X l@

33 J4 lZl@

35 lZl@

36 l01010l0l 31 40

[_N_J al

@ [N_j@ 42 lN 43 l@ lWl1l2-10l@

44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS lilOi IALL PERSONNEL WHO HAD BEEN INVOLVED WITH ANY RECENT MAINTENANCE PERFORMED ON 1R-ll/12 I t i ii i l WERE QUESTIONED AS TO THE VALVE LINE-UP, NOTHING COULD BE DETERMINED AS TO WHY THE I i,i2i iVALVES WERE OPEN. TO PREVENT A SIMILAR OCCURRENCE, A CAUTION TAG HAS BEEN PLACED ON l

[ i l 3 l l THE BYPASS VALVES. THIS CAUTION TAG WILL BE UTILIZED UNTIL DESIGN CHANGE RFC 12-2448 l m iIS COMPLETED. THE NEW SYSTEM BEING INSTALLED BY THE RFC DOES NOT HAVE BYPASS VALVES. l ST S  % POWE R OTHER STATUS Dis O RV DISCOVERY DESCRIPTION Ii l5 l l E l@ l 1101 Ol@l NA l [_Aj@l VALVE LINE-UP CHECK l ACTIVITY CO TENT RELE ASED OF RELE A. AMOUNT JF ACTIVITY LOCATION OF RELE ASE L' Lc_1 LZ_1 @ t_Z_Jg"El NA l l NA l 7 8 9 10 11 44 45 80

[ PERSONNEL E XPOSURES NUMBER TYPE DESCRIPTION li l 71 101010 l@l Z l@l NA l PERSONNEL INJURIES l NUMBE R DESCRIPTION i NA l Li_1__] l o I o 1011 l@l12 80 7 8 9 S ' " ^

'TPE T ESC %PTON '' " @

l

(

W lZl@l 7 8 9 10 NA l 80 i 2 o ISdSUE l @ DESCRIPTION NA l lllllllllllllf b h o!bobb 5 PDR ngn R. A. MWR ,Hgy, b$kME o L-