Supplemental Deficiency Rept Updating Status of Improper Solenoid Valve Safety Classification.Bechtel Power Corp Mcar 1-55 Final Rept Will Be Available Oct 1980 & Util Final Deficiency Rept by Nov 1980
ML19330A900
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 07/23/1980
From: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
To:
References
PLA-515, NUDOCS 8007290716
Download: ML19330A900 (1)


Text

.

PP&L T WO N o t f H NIN T H $it E E T, AL L E N T OW N, P A. 18101 PH O N Es (213) $ 21.$l$ 1 NoAMAN W. CURT 1S V'co Pres: cent Eegieseneg & Csestruction Nuc' ear 821 5381 July 23, 1980 Mr. Boyce H. Grier Director, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 SUSQUEHANNA STEAM ELECTRIC STATION UPDATE IN THE STATUS OF IMPROPER SAFETY CLASSIFICATION FOR SOLENOID VALVES ERs 100450/100508 FILE 840-4/900-10 PLA-515 heference: PLA-483 dated May 13, 1980

Dear Mr. Grier:

This letter serves to supplement the above referenced correspondence which advised the Commission of the subject deficiency under the provisions of 10CFR50.55(e).

, PP&L has been advised by our architect engineer, Bechtel Power Corporation, that a final report on MCAR 1-55, which documents this ccadition, will be available in October, 1980. Consequently, we expect to provide our final report to the Commission in November, 1980.

Very truly yours, i

. ~

N. W. Curtis

. Vice President-Engineering & Construction-Nuclear FLW:=cb cc: Mr. Victor Stello (15)

Director-Office of Inspection & Enforcement U. S.- Nuclear Regulatory Coc: mission Washington, D.C. 20555 Mr. G. Mcdonald, Director Office of Management Information & Program Control cy U. S. Nuclear Regulatory Cocmission

/

Washington, D.C. -20555 5 Mr. Robert M. Gallo U. S. Nuclear Regulatory Co= mission  !

P. O. Box 52 Shickshinny, Pennsylvania 18655 P E N N S Y LV A NI A POWER & LIGHTCOMPANY 8 0 0 72 9 07t(s $ . _ _.