Person / Time
Site: Cook American Electric Power icon.png
Issue date: 10/02/1997
From: Blind A, Noble D
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LER-97-015, LER-97-15, NUDOCS 9710080017
Download: ML17333B063 (5)


Text

CATEGORY j.

REGULATO INFORMATION DISTRIBUTION STEM (RIDS)

ACCESSION NBR:9710080017 DOC.DATE: 97/10/02 NOTARIZED: NO DOCKET FACIL:50-315 Donald C. Cook Nuclear Power Plant, Unit 1, Indiana M 05000315 AUT<.NANP AUTHOR AFFILIATION NOBLE,D. Indiana Michigan Power Co.

BLIND,A.A. Indiana Michigan Power Co.

RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

LER 97-015-00:on 970902,interim LER lack of appropriate C radiation monitoring in drumming room results in condition outside design basis,was concluded. Normal processing of radioactive waste matl discontinued.W/971002 ltr.

DISTRIBUTION CODE: IE22T COPIES RECEIVED:LTR ENCL SIZE:

TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.

NOTES:

RECIPIENT COPIES RECIPIENT COPIES 0 ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD3-3 PD 1 1 HICKMANiJ 1 1 INTERNAL: EOD/SPD~ 2 2 AEOD/SPD/RRAB 1 1 FILE CENTE@ 1 1 NRR/DE/ECGB 1 1 NRR/DE/EEL 1 1 NRR/DE/EMEB 1 1 NRR/DRCH/HHFB 1 1 NRR/DRCH/HICB 1 1 NRR/DRCH/HOLB 1 1 NRR/DRCH/HQMB 1 1 NRR/DRPM/PECB 1 1 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 RES/DET/EIB 1 1 RGN3 FILE 01 1 1 D EXTERNAL: L ST LOBBY WARD 1 1 LITCO BRYCEiJ H 1 1 0

NOAC POOREiW. 1 1 NOAC QUEENERiDS 1 1 NRC PDR 1 1 NUDOCS FULL TXT 1 1 N

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES, RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED: LTTR 24 ENCL 24

indiana Michigan Power Company Cook Nuclear Plant One Cook Piace Bridgman. MI 491 C6 INDIANA NICHIOAN POWER October 2, 1997 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Operating Licenses DPR-58 Docket No. 50-315 Document Control Manager:

d ghh hfll lgd

'l 'llhdbblblgbl gg .3 d.'7-015-00 Sincerely, pu A. A. Blind Site Vice President lmbd

~

Attachment A. B. Beach, Region III E. E. Fitzpatrick P. A. Barrett S. J. Brewer

~/i J. R. Padgett D. Hahn Records Center, INPO NRC Resident Inspector 3

97i00800i7 97i002 PDR ADOCK 050003i5 S PDR

~ ~

l lllllllllllllllllllllllllllillllllllllll

NRC FORM 366 . NUCLEAR REGULATORY COMMISSION ROVED BY OMB NO. 3150.0104 (5-92) EXPIRES 5/31/95 ESTIMATED BURDEN PER RESPONSE TO COMPLY WITH THI INFORMATION COLLECTION REQUEST: 50.0 KRS ~

LICENSEE EVENT REPORT (LER) COMMENTS REGARDING BURDEN ESTIMATE FORWAR TO TH INFORMATION AND RECORDS MANAGEMENT BRANCH (HNB 7714), U.S. NUCLEAR REGULATORY COMMISSION/

WASHINGTON, OC 20555-0001, AND TO THE PAPERWOR REDUCTION PROJECT (3150.0104), OFFICE 0 MANAGEMENT AND BUDGET WASHINGTON DC 20503.

FACILITY NAHE (1) (2)

Donald C. Cook Nuclear Plant - Unit DOCKET NUHBER Page 1 of1 1 50-315 TITLE (4)

Interim LER - Lack of Appropriate'adiation Monitoring in Drumming Room Results in Condition Outside Design Basis MONTH DAY SEQUENTIAL REVISION FACILITY NAME DOCKET NUMBER YEAR YEAR MONTH DAY YEAR NUMBER NUMBER Cook, Unit 2 50-316 09 FACILITY NAME DOCKET NUHBER 02 97 97 015 00 10 02 97 OPERATING MODE (9) 20.2201(b) 20.2203(6)(3)(I) 50.73(a)(2)(iii) 73.71(b)

POWER 100 LEVEL (10) 20.2203(a)(2)(I) 20.2203(a)(4) 50.73(a)(2)(v) OTHER (Specify in 20.2203(a)(2)(iii) 50.36(c)(2) 50.73(a)(2)(viii)(A) Abstract below 20.2203(a)(2)(iv) 50.73(a)(2)(I) 50.73(a)(2)(viii)(B) and in Text, 20.2203(a)(2)(v) X 50.73(a)(2)(ii) 50.73(a)(2)(x) NRC Form 366A)

NAME TELEPHONE NUMBER (Include Area Code Mr. Doug Noble, Radiation Protection Superintendent 616/465-5901, x2527 REPORTABLE REPORTABLE CAUSE SYSTEM COHPONENT LNUFACTURER CAUSE SYSTEH COMPONENT MANUFACTURER TO NPRDS TO NPROS EXPECTED X YES SUBHISSION NO DATE 15 03 97 ABSTRACI'Limit to 1400 spaces, i.e., approximately 15 single-spaced typewritten lines) (16)

On September 2, 1997, with Units 1 and 2 at 100 percent Rated Thermal Power, it was concluded that the room did not meet the Final Safety Analysis Report (FSAR) criterion for the monitoring of waste storage 609'rumming and associated handling areas. Section 11.3 of the FSAR provides criterion for monitoring of waste storage and associated handling areas. Requirements established for meeting this criterion included radiation area monitors in continuous service to actuate high-activity alarms on the Control Room board annunciator. The 609'rumming room did not meet this requirement.

It was determined that this was reportable under 10 CFR 50.50.72(b)(1)(ii)(B) as a condition outside the design basis, and an ENS notification was made at 0916 hours0.0106 days <br />0.254 hours <br />0.00151 weeks <br />3.48538e-4 months <br /> on September 2, 1997. This interim LER is being submitted under 10 CFR 50.73(a)(2)(ii)(B) as a condition that was outside the design basis of the plant.

Once identified as not meeting the FSAR requirement, normal processing of radioactive waste material in the room was discontinued. Radioactive waste materials found in the room were moved to an appropriate 609'rumming storage area. Investigation into this condition continues. This condition was not safety significant based on the monitoring of material prior to placing it in the room, the room being used for low level radioactive waste only, routine radiological surveillances of the room, and the requirement that personnel are provided with electronic dosimeters for entry into the room. The final LER is scheduled to be issued by November 3, 1997.

I