ML17333A497

From kanterella
Jump to navigation Jump to search
Provides Notification of Periodic Chemical Addition Which Will Affect Turbine Room Sump Outfall 00D
ML17333A497
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 07/12/1996
From: Fitzpatrick E
AMERICAN ELECTRIC POWER CO., INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
AEP:NRC:1208Q, NUDOCS 9607150239
Download: ML17333A497 (8)


Text

CATEGORY REGULA Y INFORMATION DISTRIBUTIO SYSTEM (RIDS)

ACCESSION NBR:9607150239 DOC.DATE: 96/07/12 NOTARIZED: NO FACIL'50-315 Donald C. Cook Nuclear Power Plant, Unit 1, Indiana M DOCKET I 05000315 50-316 Donald C. Cook Nuclear Power Plant, Unit 2, Indiana M 05000316 AUTH. NAME AUTHOR AFFILIATION FITZPATRICK,E. American Electric Power Co., Inc.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Provides notification of periodic chemical addition, effecting turbine room sump outfall.

DISTRIBUTION CODE: ROOID COFIES RECEIVED:LTR g ENCL i SIZE:

TITLE: OR Submittal: General Distribution NOTES:

RECIPIE COPIES RECIPIENT COPIES ID CODE/NAM LTTR ENCL ID CODE/NAME LTTR ENCL PD3-1 LA 1 1 PD3-1 PD 1 1 HICKMAN,J 1 1 INTERNAL: FILE CENTER 01 1 1 NRR/DE/EMCB 1 1 RR DRC HTBB 1 1 NRR/DSSA/SPLB 1 1' NRR/DSSA/SRXB 1 1 NUDOCS-ABSTRACT 1 OGC/HDS2 1 0 EXTERNAL: NOAC 1 1 NRC PDR 1 1 D

N NOTE TO ALL "RZDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTEl CONTACT THE DOCUMENT CONTROL 6ESK, ROOM OWFN 5D-5(EXT. 415-2083) TO ELIMINATE YOUR NAME PROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDI TOTAL NUMBER OF COPIES REQUIRED: LTTR 12 ENCL ll

'I I

I I

American Electric r 1 Riverside Plaza Columbus, OH 4321 373 614 223 1000 ANMECSN KLKCTREC PClWKR July 12, 1996 AEP:NRC'1208Q Docket Nos.: 50-315 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:

Donald C. Cook Nuclear Plant Units 1 and 2 PERIODIC CHEMICAL ADDITION The attached notification is forwarded for your information pursuant to Appendix B of the Donald C. Cook Nuclear Plant Environmental Technical Specifications. The sub]ect of this notification concerns a periodic chemical addition which will affect the turbine room sump outfall.

Should you have any questions or concerns regarding this notification, please contact Mr. John Carlson at 616-465-5901, extension 1153

'incerely, E. E. Fitzpatrick Vice President jen Attachment c; A. A. Blind G. Charnoff J. Miller NFEM Section Chief NRC Resident Inspector - Bridgman J. R. Padgett 9607i 50239,'.960712 PDR- ~~ADOCK'050003'L5 P PDR

ATTACHMENT TO AEP:NRC:1208Q LETTER: D. M. FITZGERALD TO F. MORLEY, DATED JULY 1, 1996

American Electric Po~

Cook Nuclear Plant One Gook Place Bridgrnan. Ml 49106 616 465 6901 AN MICA'LECTRlC POMfM Mr. Fred Morley, Surface Water Quality Division Mr. Thomas Leep, Waste Management Division Michigan Department of Environmental Quality 621 North Tenth Street P.O. Box 355 Plainwell, Ml 49080 July 1, 1996

Subject:

NPDES Permit MI0005827

Dear Messrs. Morley and Leep:

As required by Part ll.A.2 of the Cook Nuclear Plant National Pollutant Discharge Elimination System (NPDES) Permit No. MI0005827, we are providing notification of a periodic chemical addition which will affect Outfall 00D, Turbine Room Sump.

Betz Depositrol 855D will be used to clean the Plant Heater Drain Sump Pumps. Cleaning is required due to calcium carbonate scale which builds up in the pump casings and associated piping. The associated sumps discharge to the plant Turbine Room Sump, and are neutralized if necessary before being discharged via Outfall 00D.

A similar notification was made on January 15, 1995, to use Betz Depositrol 855D to clean calcium carbonate deposits from the Heater Drain Sump Pumps, which are failing at a high rate due to a calcium carbonate buildup on the casing and impellers. The January 15, 1995 notification contained a plan to add Depositrol 855D on a monthly schedule to the sumps. Due to persistent pump failures, we have found it necessary to increase the addition fro'm monthly to daily.

Betz Depositrol 855D will be added to each of two separate sumps on an as needed basis (approximately daily.) We estimate that up to one gallon of 855D will to be added to each sump per treatment. The total estimated volume of Depositrol 855D used per year is approximately 365 gallons.

The deposits removed by this operation, consisting mainly of sodium chloride, sodium carbonate, and calcium carbonate, will be discharged via Outfall 00D. A dilution flow of approximately 250 gallons per minute will be achieved.

Page 2 Mr. Fred Morley Re: NPDES Permit MI0005827 A copy of the Material Safety Data Sheet (MSDS) for Oepositrol 8550 is attached. Proprietary MSDS information has been previously sent to your office from Betz.

Please contact John Garison at (616} 465-5901 ext. 1153 with any questions you may have regarding this notification.

Sincerely, PCZra P~/Ci( c D.M. Fitzgerald Environmental, Safety and Health Superintendent c: S. Heaton, GLEAS SWQD-Lansing D. MacKenzie-Taylor, WMO-Lansing M. Fields, SWQD-Plainwell T. Unseld, WMO-Plainwell

Page 3 Mr. Fred Morley Re: NPDES Permit MI0005827 1 certify under penalty of law that have personally examined and am 1

familiar with the information submitted on this and all attached documents; and based on my inquiry of those individuals immediately responsible for obtaining the information, believe the submitted information is true, 1

accurate and complete. am aware that there are significant penalties for 1

submitting false information, including the possibility of fine and imprisonment.

E.

A.A. Blind Site Vice President

bc: A.A. Blind J.P. Garison S.J. Brewer C.E. Hawk W.T. MacRae B.K. Zordell