ML16293A365
Text
Appendix C-Analytical Methodology.
Appendix C-Analytical Methodology Analytical Parameter Method MDC Units Standard Analysis Gross Alpha
- EPA 900.0 Mod/SW 4
pCi/g.
Gross Beta (Nonvolatile Beta)
EPA 900.0 Mod/SW 10 pCi/g Gamma Scan DOE HASL'300 0.1 (Cs-137
'pCi/g 4.5.2.3/Ga-Ol-R Onlvl Expanded Analysis An;i-241,Cm~24i,Cm-243/244,Cm-24S/246.
DOE HASL 300 1
pCi/g Am-OS-RC Mod C-14 EPA EERF c~of Mod 2
pCi/g l-;129 DOE HASL 300 1-01 1
pCi/g Npc237 DOE HASL 300. -
1 pCl/g
. Pu-23'8,.239/240
.DOE HASC300
- 1 pti/g:
Pu'-ll:RC Mod:"
Pu-241'
-EPA 905.0Mod 2.
pCi/g Tc-02-RC Mod pCi/g U~232 DOE HASL 300 1
- U-02-RC Mod
_ 1)~233/:234; U-235/236, U-238 r)ci/g '
DOE HASL 300 1
U-02-~C Mod H-3 EPA 906.0 Mod 6
pCi/g, Th-01-RC Mod Th-228, T_b-230, Th-232 DOE HASL 300 1
pCi/g Th~Ol-RC Mod Raaium 226 (20;day ingrowth)
DOEHASL 300*
- 1
- pCi/,g..:
4.5.2.3/GA~Ol:,R Radium 228 DOEHASL 300 3
pCi/g 4.5.2.3/GA-01-R