ML14351A171
| ML14351A171 | |
| Person / Time | |
|---|---|
| Site: | Hatch (DPR-057, NPF-005) |
| Issue date: | 12/17/2014 |
| From: | Brian Bonser NRC/RGN-II/DRS/PSB1 |
| To: | Vineyard D Southern Nuclear Operating Co |
| Linda K. Gruhler 404-997-4633 | |
| References | |
| Download: ML14351A171 (8) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 December 17, 2014 Mr. David R. Vineyard Southern Nuclear Operating Company, Inc.
Edwin I. Hatch Nuclear Plant 11028 Hatch Parkway North Baxley, GA 31513
SUBJECT:
EDWIN I. HATCH NUCLEAR PLANT - NOTIFICATION OF INSPECTION AND REQUEST FOR INFORMATION
Dear Mr. Vineyard:
During the weeks of February 09 - 13, 2015, and February 23 - 27, 2015, the U.S. Nuclear Regulatory Commission (NRC) will perform a baseline Occupational Radiation Safety Inspection at the Edwin I. Hatch Nuclear Plant. The inspection will consist of NRC Inspection Procedures (IPs) 71124.01, 71124.02, 71124.03, 71124.04, 71124.05, and Radiation Safety sections of 71151.
Experience has shown that this inspection is resource-intensive for both the NRC inspectors and your staff. In order to minimize the impact to your onsite resources and to ensure a productive inspection, we have enclosed a request for documents needed for this inspection. It is important that all of these documents are up-to-date and complete, in order to minimize the number of additional documents requested during the preparation and/or the on-site portions of the inspection. The NRC requests that these documents be provided to the NRC staff no later than January 23, 2015.
We have discussed the schedule for these inspection activities with your staff, and understand that our regulatory onsite contact for this inspection will be Mr. Steve Tipps of your organization.
If there are any questions about this inspection or the material requested, please contact the lead inspector, Carmen Dykes at 404-997-4401, or the Plant Support Branch 1 Chief, Brian Bonser at 404-997-4653.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public inspections, exemptions, requests for withholding, of the NRCs Rules of Practice, a copy of this letter, and its Enclosure, will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS); accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
This letter does not contain new, or amended, information collection requirements subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
D. Vineyard 2
requirements were approved by the Office of Management and Budget under control numbers 3150-0044, 3150-0135, 3150-0014, 3150-0011, and 3150-0008. The NRC may not conduct or sponsor, and a person is not required to respond to, a request for information, or an information collection requirement, unless the requesting document displays a currently valid Office of Management and Budget control number.
Sincerely,
/RA/
Brian Bonser, Chief Plant Support Branch 1 Division of Reactor Safety Docket Nos. 50-321 and 50-366 License Nos. DPR-57 and NPF-5
Enclosure:
Document Request List cc: Distribution via Listserv
ML14351A171 SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DRS/PSB1 RII:DRS/PSB1 SIGNATURE CMD4 WTL for BRB1 NAME C. Dykes B. Bonser DATE 12/ 17 /2014 12/ 17 /2014 E-MAIL COPY YES NO YES NO
Enclosure DOCUMENT REQUEST LIST Site: Hatch Nuclear Plant Report Number: 05000321-366/2015001 Inspection Dates:
February 09 - 13, 2015 and February 23 - 27, 2015 Inspection Procedures:
IP 71124.01 Radiological Hazard Assessment and Exposure Controls IP 71124.02 Occupational As Low As Reasonably Achievable Planning and Controls IP 71124.03 In-Plant Airborne Radioactivity Control and Mitigation IP 71124.04 Occupational Dose Assessment IP 71124.05 Radiation Monitoring Instrumentation IP 71151 Performance Indicator Verification NRC Inspector:
Carmen Dykes (Carmen.Dykes@nrc.gov)
Health Physicist US NRC Region II 404-997-4401 Note: The current version of these documents is expected unless specified otherwise.
Electronic media is preferred if readily available. The preferred file format is Word or searchable.pdf files on CDROM. [Note that the inspectors cannot accept data provided on USB or flash drives due to NRC IT security policies.] Please organize the information as it is arranged below to the extent possible. Experience has shown that a well-organized CD leads to a more efficient inspection, and lessens additional burden on licensee staff. During the inspection, the inspectors may request additional documents.
General Information Needed
- 1. List of primary contacts for each inspection area; with phone numbers.
- 2. Electronic copy of Updated Final Safety Analysis Report (UFSAR) chapters 11 and 12.
(radwaste and radiation protection)
- 4. Corrective action program (CAP) procedure.
- 5. Outage schedule of major activities (Gantt chart if available).
- 6. Current Part 61 Analysis Results for dry active waste (DAW) 71124.01 Radiological Hazard Assessment and Exposure Controls (Last Inspected 2/10/14)
- 1. List of outage Radiation Work Permits (RWPs).
- 2. Procedures related to Health Physics (HP) controls (e.g., Posting, labeling, surveys, RWPs, contamination control, high radiation area(HRA)/locked high radiation area (LHRA)/very high radiation area (VHRA) control, key control, control of divers, special controls during fuel offload, hot spots, etc.).
- 3. List of locations of all locked HRAs and VHRAs. Include areas with the potential to become a LHRA during routine operations or outages.
2
- 4. Procedures related to release of personnel and materials (e.g., release surveys, decontamination, guidance for alarm followup, etc.).
- 5. List of Nationally Tracked Sources and any change-of-ownership or inventory transactions.
- 6. Inventory list of all sealed sources stored onsite.
- 7. List of all non-fuel items stored in spent fuel pool.
- 8. All self-assessment or audit covering HP controls since January 2014 (if none, then provide the most recent).
- 9. LIST of condition reports (CRs) regarding radiological hazard assessment and exposure controls (e.g., HRA/LHRA/VHRA controls, posting, surveys, radworker performance, HP tech performance) issued since January 2014. [This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
- 10. All CRs related to Nationally Tracked Sources since January 2014.
71124.02 Occupational As Low As Reasonably Achievable Planning and Controls (Last Inspected 2/25/2013)
- 1. All procedures related to As Low As Reasonably Achievable (ALARA) (e.g., temporary shielding, ALARA planning, source term reduction, etc.).
- 2. List of top five dose jobs for the upcoming refueling outage and ALARA planning packages, if available.
- 3. List of temporary shielding requests generated for the upcoming outage.
- 4. Crudburst/cleanup and trending point data for last two outages.
- 5. Source term reduction strategic plan, if available.
- 6. Most recent self-assessment or audit of ALARA program.
- 7. Most recent annual ALARA report, and most recent refueling outage report, if available.
- 8. Annual ALARA goals for 2015 and the methodology utilized to make the projections.
- 9. Completed ALARA packages (including post-job reviews) for five work activities completed during the previous outage which had the greatest collective dose.
- 10. LIST of CRs related to ALARA since January 2013. [This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
71124.03 In-Plant Airborne Radioactivity Control and Mitigation (Last Inspected 2/25/2013)
- 1. Procedures related to airborne monitoring and control (e.g., use of containment purge, use of portable HEPA/charcoal units, temporary ventilation enclosures, use of continuous air monitors (CAMs), air sampling guidance, Alpha air sampling, etc.).
- 2. Procedures related to the use of respiratory protection devices, (e.g., self-contained breathing apparatus (SCBA), Total Effective Dose Equivalent (TEDE)-ALARA guidance, powered air purifying respirators (PAPRs), storage, maintenance, training, quality assurance (QA), fit-testing, etc.).
- 3. All records of grade D air certification for supplied air system, and SCBA filling equipment since January 2013.
- 4. SCBA qualification records
- a. Vendor training certificates for all individuals qualified to repair SCBA
- b. List of all licensed operators qualified to use SCBA
- c. List of all maintenance personnel qualified to use SCBA
- 5. Documentation for last two surveillances performed on SCBA stored for emergency use.
3
- 6. Two most recent HEPA filter dioctyplthalate (DOP) and charcoal test results; or the following ventilation systems:
- a. Main Control Room
- b. Auxiliary Ventilation Exhaust
- 7. Most recent audit or self-assessment covering airborne controls and respiratory protection.
- 8. LIST of CRs related to airborne monitoring and respiratory protection since January 2013.
[This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
71124.04 Occupational Dose Assessment (Last Inspected 2/25/2013)
- 1. Procedures related to occupational dose assessment (e.g., external dose monitoring, dosimetry issuance and use, unusual dosimetry occurrences, multi-badging/extremity dosimetry/badge relocation, Effective Dose Equivalent, personnel contamination events, storage/care of personal dosimeters, use of electronic dosimeters, in-vivo and in-vitro internal dose assessment, skin dose assessment, quality control for whole body counter (WBC), use of passive monitoring, if applicable, declared pregnant workers).
- 2. National Voluntary Laboratory Accreditation Program (NVLAP) accreditation documentation for current dosimetry used by site.
- 3. LIST of all positive whole body counts, in vitro, or air-sampling analyses which resulted in an assigned Committed Effective Dose Equivalent (CEDE), equal to or exceeding, 10 millirem since January 2013. [Note: Only a listing should be provided for use by the inspectors to select a sample of issues for in-depth review during the onsite inspection.]
- 4. LIST of all personnel contamination events identified since January 2011. Include full documentation for any personnel containment events (PCEs) requiring skin dose assessment. [Note: Only a listing should be provided, for use by the inspectors, to select a sample of issues for in-depth review during the onsite inspection, however; please include full dose assessment documentation as applicable.]
- 5. Most recent audit or self-assessment of the dosimetry program, and the most recent audit of the lab that processes site dosimetry.
- 6. LIST of CRs generated since January 2013, for internal or external dosimetry issues/events.
[This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
71124.05 - Radiation Monitoring Instrumentation (Last Inspected 2/25/2013)
- 1. Procedures/Guidance Documents for:
- a. Use of portable instrument calibrators (e.g., Shepherd calibrator).
- b. Calibration and functional test/source checks of portable radiation detection instrumentation.
- c. Calibration and functional tests of small article monitor (SAM); personnel contamination monitor (PCM); portal monitor (PM); WBC equipment; and CAMs.
- e. Collection and analysis of high-range, post-accident effluent samples.
- f.
QA program for count room instruments.
- 2. Provide the last two calibration records for the following Unit 1 monitors:
- a. Reactor building ventilation exhaust radiation monitors
4
- b. Vent stack radiation monitors
- c. Drywell high range area monitors
- d. Main control room air intake radiation monitors
- e. Radwaste area monitors
- f. List of the last two calibration dates for listed monitors in Unit 2
- 3. Documentation for the sources used to calibrate the above requested monitors showing traceability to a national standard, National Institute of Standards & Technology/National Bureau of Standards (NIST/NBS), and to the primary calibration, as applicable.
- 4. The last two surveillances performed on the Post-accident Sampling System (PASS).
- 5. The last test record of the instrument calibrator (Shepherd validation testing/dose rate curves).
- 6. Last two system health reports for the Radiation Monitoring system.
- 7. Copies of all audits, self-assessments, and/or reviews of radiation monitoring equipment, and portable radiation survey instruments, generated since January 2013. The records should include any reviews conducted of vendor facilities (e.g., outside calibration laboratories, as applicable).
- 8. LIST of CRs generated since January 2013, related to portable instruments, effluent and area monitors, CAMs, radiological controlled area (RCA) release point monitors, WBCs, and count room instruments. [This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
Performance Indicator Verification (Occupational and Public Cornerstones)
(Last Inspected 2/10/2014)
- 1. Procedure for gathering and reporting performance indicator (PI) data.
- 2. List of all CRs related to effluent dose/offsite dose calculation manual (ODCM) issues since January 2014. [This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
- 3. LIST of all CRs related to LHRA/VHRA issues, and unintended dose issues since January 2011. [This should be a list of corrective action documents containing a CR number and brief description, not full CRs.]
- 4. Most recent gaseous and liquid effluent release permits showing year-to-date doses to the public.
- 5. LIST of electronic dosimeter (ED) alarms since January 2014 (dose and dose rate).
LIST OF ACRONYMS ALARA As Low As Reasonably Achievable ARM Area Radiation Monitor CAMs Continuous Air Monitors CAP Corrective Action Program CEDE Committed Effective Dose Equivalent CRs Condition Reports DAW Dry Active Waste DOP Dioctyplthalate ED Electronic Dosimeter HP Health Physics HRAs High Radiation Areas IP Inspection Procedure
5 ISFSI Independent Spent Fuel Storage Installation LHRA Locked High Radiation Area NIST National Institute of Standards and Technology NVLAP National Voluntary Laboratory Accreditation Program ODCM Offsite Dose Calculation Manual PAPRs Powered Air Purifying Respirators PASS Post-accident Sampling System PCE Personnel Containment Event PCM Personnel Contamination Monitor PIs Performance Indicators PM Portal Monitor QA Quality Assurance QC Quality Control RCA Radiological Controlled Area RSPS Risk Significant Planning Standard RWPs Radiation Work Permits SAM Small Article Monitor SCBA Self-contained Breathing Apparatus TEDE Total Effective Dose Equivalent UFSAR Updated Final Safety Analysis Report VHRA Very High Radiation Area WBC Whole Body Counter