Letter Sequence Acceptance Review |
---|
|
|
MONTHYEARML14212A0712014-07-30030 July 2014 10 CFR 50.55a Request No. Vr 05: Proposed Alternative to Lnservice Testing Requirements Pursuant to 10 CFR 50.55a(a)(3)(ii) Project stage: Request ML14220A1352014-08-0606 August 2014 NRR E-mail Capture - Monticello Nuclear Generating Plant Acceptance Review Relief Request RR VR05 Project stage: Acceptance Review ML14223A5812014-08-27027 August 2014 Alternative Request Vr 05 to the Testing Requirements of the ASME OM Code for the Fifth 10-Year Inservice Inspection Program Interval Project stage: Acceptance Review 2014-08-27
[Table View] |
|
---|
Category:Code Relief or Alternative
MONTHYEARML23248A2092023-09-18018 September 2023 Proposed Alternative VR-11 to the Requirements of the ASME OM Code Associated with Periodic Verification Testing of MO-2397, Reactor Water Cleanup Inboard Isolation Valve ML23123A4222023-05-16016 May 2023 Request RR 001 to Use Later Edition of ASME BPV Section XI Code for Cisi Program ML23107A2852023-04-25025 April 2023 Authorization and Safety Evaluation for Alternative Request PR-08 ML23017A2222023-01-13013 January 2023 Verbal Authorization of Proposed Alternative PR-08 Regarding Inservice Testing Requirements of Certain High Pressure Coolant Injection System Components (EPID L-2022-LLR-0088) (Email) ML22314A2162022-11-16016 November 2022 Withdrawal of Alternative Request VR-08 ML22270A2312022-09-30030 September 2022 Authorization and Safety Evaluation for Alternative Request No. VR-10 ML22208A1952022-08-0303 August 2022 Summary of July 26, 2022, Meeting with Northern States Power Company, Doing Business as Xcel Energy, Related to the Alternative Request for Excess Flow Check Valves at Monticello Nuclear Generating Plant ML22126A1052022-06-21021 June 2022 Authorization and Safety Evaluation for Alternative Request No. VR-01 ML22154A5502022-06-0707 June 2022 Authorization and Safety Evaluation for Alternative Request No. PR-02 ML22126A1342022-05-12012 May 2022 Authorization and Safety Evaluation for Alternative Request No. PR-05 ML22130A6562022-05-11011 May 2022 Authorization and Safety Evaluation for Alternative Request No. PR-04 ML22098A1272022-05-0202 May 2022 Authorization and Safety Evaluation for Alternative Request No. VR-02 ML22110A1232022-04-25025 April 2022 Withdrawal of Relief Requests PR-09 and VR-07 (Epids: L 2021 Llr 0095 and L 2022 Llr 0021) ML22018A1772022-01-21021 January 2022 Authorization and Safety Evaluation for Alternative Request No. VR-05 ML20307A0172020-11-0202 November 2020 Request for Alternative for Core Support Structure Weld Examination ML20174A5452020-07-15015 July 2020 Request for Alternative for Pressure Isolation Valve Testing ML20135G9922020-05-29029 May 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML18270A0152018-10-19019 October 2018 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME OM Code L-MT-18-023, 10 CFR 50.55a Request RR-012: Inservice Inspection Impracticality in Accordance with 10 CFR 50 .55a(g)(5)(iii) During the Fifth Ten-Year Interval2018-05-11011 May 2018 10 CFR 50.55a Request RR-012: Inservice Inspection Impracticality in Accordance with 10 CFR 50 .55a(g)(5)(iii) During the Fifth Ten-Year Interval ML17122A1572017-05-15015 May 2017 Request for Alternative to Use Code Case OMN-20 for the Fifth 10-Year Inservice Testing Interval ML16208A4622016-08-0303 August 2016 Safety Evaluation for Request for Alternative Associated with Reactor Pressure Vessel Internals and Components Inspection for the Fifth 10-Year Interval L-MT-15-083, 10 CFR 50.55a Request No. RR-010: Request for Approval of an Alternative to Apply the BWRVIP Guidelines in Lieu of Specific ASME Section XI Code Requirements for Reactor Pressure Vessel Internals and Components Inspection2015-11-20020 November 2015 10 CFR 50.55a Request No. RR-010: Request for Approval of an Alternative to Apply the BWRVIP Guidelines in Lieu of Specific ASME Section XI Code Requirements for Reactor Pressure Vessel Internals and Components Inspection ML15028A1522015-02-19019 February 2015 Relief Request RR-009 Regarding Relief from Examination Coverage Requirements of Section XI of the ASME Code for the Fifth 10-Year Inservice Inspection Program Interval ML15013A0362015-01-23023 January 2015 Relief Request RR-008 Alternative to ASME Code, Section XI, Examination Requirements for the Reactor Pressure Vessel Shroud Support Plate Welds H8 and H9 for the Fifth 10-Year ISI Interval ML14223A5812014-08-27027 August 2014 Alternative Request Vr 05 to the Testing Requirements of the ASME OM Code for the Fifth 10-Year Inservice Inspection Program Interval ML12244A2722012-09-26026 September 2012 Relief from the Requirements of ASME OM Code for the Fifth Ten-Year IST Program Interval (TAC Nos. ME8067, ME8088 Through ME8096) ML12180A5882012-07-12012 July 2012 Approval of ISI Relief Request RR-007 for the Fifth 10-year Interval ML1020006722010-07-28028 July 2010 Approval of Alternative to Use ASME Code Case N-705 to Address Cracks at the Standby Liquid Control Tank L-MT-10-014, Request 10 CFR 50.55a Request 17: Extension of Permanent Relief from Volumetric Examination of Reactor Pressure Vessel Circumferential Shell Welds for the Renewed Operating License Term2010-03-12012 March 2010 Request 10 CFR 50.55a Request 17: Extension of Permanent Relief from Volumetric Examination of Reactor Pressure Vessel Circumferential Shell Welds for the Renewed Operating License Term ML0617103642006-07-0303 July 2006 Monticello Nuclear Generating Plant, Palisades Nuclear Plant, Point Beach Nuclear Plant Units 1 and 2, Prairie Island Nuclear Generating Plant, Units 1 and 2 - Use of ASME Code Case N-513-2 L-MT-05-074, Request to Use Subsequent Edition and Addenda of ASME Code for Inservice Testing2005-07-29029 July 2005 Request to Use Subsequent Edition and Addenda of ASME Code for Inservice Testing ML0505600492005-03-0808 March 2005 Fourth 10-Year Inservice Inspection Interval Request for Relief to Use Code Case N-661 ML0436300192005-01-0606 January 2005 Relief, Fourth 10-year Inservice Inspection Interval Request for Relief No. 4, MC2222 ML0407004152004-03-25025 March 2004 Third 10-Year Interval Inservice Inspection Request for Relief RR-17, Involving Repair/Replacement Activity on the Topworks of Main Steam Safety Relief Valve (SRV) G ML0401607382004-02-26026 February 2004 Prairie, Units 1 and 2, Kewaunee, Point Beach, Units 1 and 2, Palisades, Re Request for Alternatives to ASME Section XI, Appendix Viii, Supplement 10 ML0320401572003-10-0303 October 2003 Relief Request No. 7, Fourth 10-Year Interval Inservice Inspection Program Plan L-MT-03-045, Request for Approval of Inservice Inspection Program Third 10-Year Interval Relief Request No. 172003-08-27027 August 2003 Request for Approval of Inservice Inspection Program Third 10-Year Interval Relief Request No. 17 ML0320605802003-08-0707 August 2003 Relief, Fourth 10-Year Interval Inservice Testing Program ML0317002092003-07-17017 July 2003 Relief Request, Nos. PR-01, PR-02, PR-03, PR-04, PR-05, and VR-02 Related to the Fourth 10-Year Interval Inservice Testing Program L-MT-03-048, Request for Authorization of Inservice Inspection Program Fourth 10-Year Interval Relief Request No. 82003-06-12012 June 2003 Request for Authorization of Inservice Inspection Program Fourth 10-Year Interval Relief Request No. 8 ML0316008642003-06-0909 June 2003 Relief Request, Fourth 10-Year Interval Inservice Inspection Program Plan Relief Request No. 5, TAC No. MB6956 ML0314001192003-05-19019 May 2003 Relief, Third 10-Year Interval Inservice Inspection Relief Request No 16, Parts a, B, and C L-MT-03-001, Relief Request No. Pr 06 for Fourth 10-Year Inservice Testing Interval - High Pressure Coolant Injection Pump Testing2003-05-0606 May 2003 Relief Request No. Pr 06 for Fourth 10-Year Inservice Testing Interval - High Pressure Coolant Injection Pump Testing 2023-09-18
[Table view] Category:Letter
MONTHYEARML24025A9362024-01-31031 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0055 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) IR 05000263/20230042024-01-31031 January 2024 Integrated Inspection Report 05000263/2023004 ML24024A0722024-01-24024 January 2024 Independent Spent Fuel Storage Installation, Onticello, Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation IR 05000263/20244012024-01-22022 January 2024 Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection 05000263/2024401 L-MT-23-054, Subsequent License Renewal Application Supplement 82024-01-11011 January 2024 Subsequent License Renewal Application Supplement 8 L-MT-23-047, License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data2023-12-29029 December 2023 License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data L-MT-23-056, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 22023-12-18018 December 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 2 ML23349A0572023-12-15015 December 2023 and Independent Spent Fuel Storage Installation, Revision to Correspondence Service List for Northern States Power - Minnesota IR 05000263/20234022023-12-13013 December 2023 Security Baseline Inspection Report 05000263/2023402 L-MT-23-042, 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462023-12-11011 December 2023 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-23-052, Subsequent License Renewal Application Supplement 72023-11-30030 November 2023 Subsequent License Renewal Application Supplement 7 L-MT-23-051, Update to the Technical Specification Bases2023-11-28028 November 2023 Update to the Technical Specification Bases L-MT-23-049, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 12023-11-21021 November 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 ML23319A3182023-11-15015 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation IR 05000263/20230032023-11-13013 November 2023 Integrated Inspection Report 05000263/2023003 and 07200058/2023001 L-MT-23-043, 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-092023-11-13013 November 2023 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-09 L-MT-23-038, License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.62023-11-10010 November 2023 License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.6 L-MT-23-046, Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 12023-11-0909 November 2023 Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 1 ML23291A1102023-10-23023 October 2023 Environmental Audit Summary and RCIs and RAIs ML23285A3062023-10-12012 October 2023 Implementation of the Fleet Standard Emergency Plan for the Monticello Nuclear Generating Plant and the Prairie Island Nuclear Generating Plant L-MT-23-041, Subsequent License Renewal Application Response to Request for Confirmation of Information Set 22023-10-0303 October 2023 Subsequent License Renewal Application Response to Request for Confirmation of Information Set 2 L-MT-23-037, Subsequent License Renewal Application Response to Request for Additional Information Set 32023-09-22022 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 3 ML23262B0372023-09-19019 September 2023 Response to NRC Request for Additional Information Regarding the 2023 Monticello and Prairie Island Plant Decommissioning Funding Status Reports ML23248A2092023-09-18018 September 2023 Proposed Alternative VR-11 to the Requirements of the ASME OM Code Associated with Periodic Verification Testing of MO-2397, Reactor Water Cleanup Inboard Isolation Valve ML23256A1682023-09-13013 September 2023 Independent Spent Fuel Storage Installation and Monticello Nuclear Generating Plant - Voluntary Security Clearance Program 2023 Insider Threat Program Self-Inspection IR 05000263/20230102023-09-0707 September 2023 Commercial Grade Dedication Inspection Report 05000263/2023010 L-MT-23-036, Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 62023-09-0505 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 6 ML23214A2412023-08-31031 August 2023 Letter: Aging Management Audit - Monticello Unit 1 - Subsequent License Renewal Application IR 05000263/20230052023-08-30030 August 2023 Updated Inspection Plan for Monticello Nuclear Generating Plant (Report 05000263/2023005) L-MT-23-035, Subsequent License Renewal Application Supplement 52023-08-28028 August 2023 Subsequent License Renewal Application Supplement 5 ML23241A9732023-08-21021 August 2023 Request for Scoping Comments Concerning the Environmental Review of Monticello Nuclear Generating Plant, Unit 1, Subsequent License Renewal Application (Docket No. 50-263) L-MT-23-034, Subsequent License Renewal Application Response to Request for Additional Information Set 12023-08-15015 August 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 1 ML23222A0122023-08-10010 August 2023 Independent Spent Fuel Storage Installation and Monticello Nuclear Generating Plant - Changes in Foreign Ownership, Control or Influence ML23215A1312023-08-0909 August 2023 License Renewal Regulatory Audit Regarding the Environmental Review of the Subsequent License Renewal Application IR 05000263/20230022023-08-0707 August 2023 Plantintegrated Inspection Report 05000263/2023002 L-MT-23-028, 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report2023-07-31031 July 2023 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report L-MT-23-032, 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-112023-07-31031 July 2023 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-11 ML23198A0412023-07-28028 July 2023 LRA Availability Letter ML23206A2342023-07-25025 July 2023 Independent Spent Fuel Storage Installation, and Monticello Nuclear Generating Plant, Changes in Foreign Ownership, Control or Influence ML23201A0352023-07-24024 July 2023 Notification of an NRC Biennial Licensed Operator Requalification Program Inspection and Request for Information ML23202A0032023-07-21021 July 2023 Independent Spent Fuel and Independent Spent Fuel Storage Installation, Monticello Nuclear Generating Plant, Submittal of Quality Assurance Topical Report (NSPM-1) L-MT-23-031, Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 12023-07-18018 July 2023 Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 1 ML23195A1732023-07-14014 July 2023 Revision of Standard Practice Procedures Plan IR 05000263/20235012023-07-13013 July 2023 Emergency Preparedness Inspection Report 05000263/2023501 2024-01-31
[Table view] Category:Safety Evaluation
MONTHYEARML23248A2092023-09-18018 September 2023 Proposed Alternative VR-11 to the Requirements of the ASME OM Code Associated with Periodic Verification Testing of MO-2397, Reactor Water Cleanup Inboard Isolation Valve ML23107A2852023-04-25025 April 2023 Authorization and Safety Evaluation for Alternative Request PR-08 ML23079A0742023-04-11011 April 2023 Request RR-003 to Use Later Edition of ASME Section XI Code for ISI Code of Record ML22357A1002023-03-31031 March 2023 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendments Standard Emergency Plan and Consolidated Emergency Operations Facility ML23012A1562023-01-13013 January 2023 Issuance of Amendment No. 210 Re Revised Methodologies for Determining the Core Operating Limits (EPID L-2021-LLA-0144) - Non-proprietary ML22318A2152022-12-27027 December 2022 Issuance of Amendment No. 209 Ten-Year Inspection of the Diesel Generator Fuel Oil Storage Tank ML22264A1062022-10-31031 October 2022 Issuance of Amendment No. 208 Residual Heat Removal Drywell Spray Header and Nozzle Surveillance Frequency ML22270A2312022-09-30030 September 2022 Authorization and Safety Evaluation for Alternative Request No. VR-10 ML22154A5502022-06-0707 June 2022 Authorization and Safety Evaluation for Alternative Request No. PR-02 ML22126A1342022-05-12012 May 2022 Authorization and Safety Evaluation for Alternative Request No. PR-05 ML22098A1272022-05-0202 May 2022 Authorization and Safety Evaluation for Alternative Request No. VR-02 ML22018A1772022-01-21021 January 2022 Authorization and Safety Evaluation for Alternative Request No. VR-05 ML21223A2802021-10-15015 October 2021 Issuance of Amendment No. 207 Adoption of TSTF-564 Safety Limit MCPR ML21148A2742021-07-12012 July 2021 Issuance of Amendment No. 206 TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML20352A3492021-01-0808 January 2021 Issuance of Amendment No. 205, Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-582, RPV WIC Enhancements, and TSTF-583-T, TSTF-582 Diesel Generator Variation ML20346A0972020-12-21021 December 2020 Request for Alternative for Examination of Reactor Pressure Vessel Threads in Flange ML20336A1602020-12-0909 December 2020 Request to Use a Provision of a Later Edition of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI ML20307A0172020-11-0202 November 2020 Request for Alternative for Core Support Structure Weld Examination ML20210M0142020-09-0808 September 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendment Nos. 204, 231, and 219 TSTF-529 Clarify Use and Application Rules ML20153A8042020-07-31031 July 2020 Co. - Issuance of Amendments Revising Emergency Action RA3 ML20174A5452020-07-15015 July 2020 Request for Alternative for Pressure Isolation Valve Testing ML20153A4012020-06-0101 June 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML20135G9922020-05-29029 May 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML20134H9582020-05-29029 May 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML19255F5822019-10-0101 October 2019 Safety Evaluation Regarding Implementation of Hardened Containment Vents Capable of Operation Under Severe Accident Conditions Related to Order EA-13-109 (CAC No. MF4376; EPID No. L-2014-JLD-0052) ML19162A0932019-07-30030 July 2019 Issuance of Amendment No, 202 Regarding Deletion of the Note Associated with Technical Specification 3.5.1., Erccs - Operating ML19074A2692019-04-22022 April 2019 Non-Proprietary - Issuance of Amendment Revision to Technical Specifications 2.1.2 Safety Limit Minimum Critical Power Ratio ML19052A1422019-03-11011 March 2019 Correction to License Amendment No. 198 Related to Adoption of TSTF-542, Reactor Pressure Vessel Water Inventory Control ML19065A2002019-03-11011 March 2019 Correction to License Amendment No. 200 Related to Adoption of TSTF-425, Relocated Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B ML19007A0902019-01-28028 January 2019 Issuance of Amendment Adoption of TSTF-425, Relocate Surveillance Frequencies to Licensee Control-RITSTF Initiative 5B ML18291B2142018-11-26026 November 2018 Issuance of Amendment Adoption of TSTF-551 Revise Secondary Containment Surveillance Requirements ML18250A0752018-10-29029 October 2018 Issuance of Amendment Adoption of TSTF-542, Reactor Pressure Vessel Water Inventory Control ML18270A0152018-10-19019 October 2018 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME OM Code ML17345A0462018-03-0606 March 2018 Issuance of Amendment No. 197 to Adopt Changes to the Emergency Plan (CAC No. MF9560; EPID L-2017-LLA-0184) ML17319A5912017-12-10010 December 2017 Safety Evaluation Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051 ML17310B2392017-11-28028 November 2017 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendment Unit Staff Qualifications (CAC Nos. MF9545, MF9546, and MF9547; EPID L-2017-LLA-0195) ML17123A3212017-06-16016 June 2017 Issuance of Amendment Adoption of TSTF-545, Revision 3, TS Inservice Testing Program Removal and Clarify SR Usage Rule Application to Section 5.5 Testing ML17122A1572017-05-15015 May 2017 Request for Alternative to Use Code Case OMN-20 for the Fifth 10-Year Inservice Testing Interval ML17103A2352017-04-25025 April 2017 Issuance of Amendment Technical Specification 5.5.11 Primary Containment Leakage Rate Testing Program ML17013A4352017-02-27027 February 2017 Issuance of Amendment Revision to Technical Specification Surveillance Requirement 3.8.4.2 ML17054C3942017-02-23023 February 2017 Non-Proprietary Issuance of Amendment Extended Flow Window ML16320A0212016-11-28028 November 2016 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Review of Changes to the Northern States Power Company Quality Assurance Topical Report ML16244A1202016-09-0606 September 2016 Generation Plant - Interim Staff Evaluation Relating to Overall Integrated Plan in Response to Phase 2 of Order EA-13-109 (Severe Accident Capable Hardened Vents) ML16208A4622016-08-0303 August 2016 Safety Evaluation for Request for Alternative Associated with Reactor Pressure Vessel Internals and Components Inspection for the Fifth 10-Year Interval ML16196A3032016-08-0101 August 2016 Issuance of Amendment Technical Specifications Surveillance Requirement 3.5.1.3 B to Correct Alternative Nitrogen System Pressure (Cac. No. MF6704) ML16125A1652016-06-21021 June 2016 Issuance of Amendment Technical Specifications Task Force (TSTF) Standard Technical Specifications (STS) Change Traveler TSTF-523, Revision 2 Generic Letter 2008-01, Managing Gas Accumulation ML15175A0162015-06-30030 June 2015 Staff Evaluation of 10 CFR 50.54(p)(2) Changes to Security Plans ML15072A1412015-06-0505 June 2015 Issuance of Amendment No. 188 Regarding Transition to Areva Atrium 10XM Fuel and Areva Safety Analysis Methods ML15154A4772015-06-0505 June 2015 Safety Evaluation Regarding License Amendment No. 188 Associated with Areva Atrium 10XM Fuel Transition (TAC No. MF2479) - (Redacted) ML14358A0392015-02-20020 February 2015 Northern States Power Company, Minnesota (NSPM) - Monticello Nuclear Generating Plant, Prairie Island Nuclear Generating Plant, Prairie Island ISFSI - Review of Changes to the NSPM Quality Assurance Topical Report 2023-09-18
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August 27, 2014 Karen D. Fili Site Vice-President Northern States Power Company - Minnesota Monticello Nuclear Generating Plant 2807 West County Road 75 Monticello, MN 55362-9637
SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT -ALTERNATIVE TO THE TESTING REQUIREMENTS OF THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS CODE FOR OPERATIONS AND MAINTENANCE OF NUCLEAR POWER PLANTS FOR THE FIFTH 10-YEAR INSERVICE INSPECTION PROGRAM INTERVAL (TAG NO. MF4544)
Dear Mrs. Fili:
By letter dated July 30, 2014, Northern States Power Company, a Minnesota corporation (NSPM, the licensee), doing business as Xcel Energy, submitted a request to the U.S. Nuclear Regulatory Commission (NRC) for authorization of an alternative to the testing requirements of the American Society of Mechanical Engineers (ASME) Code for Operations and Maintenance of Nuclear Power Plants (OM Code), 2004 Edition with Addenda through OMb Code-2006, for the Monticello Nuclear Generating Plant (MNGP).
Specifically, pursuant to Title 10 of the Code of Federal Regulations (1 0 CFR), Section 50.55a(g)(3)(ii), the licensee requested to defer its quarterly valve exercise testing on the inboard and outboard main steam line drain valves (M0-2373 and M0-2374) to the next MNGP refueling outage in spring 2015 on the basis that complying with the specified requirement would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
The NRC staff has reviewed MNGP Request No. VR 05 and concludes, as set forth in the enclosed safety evaluation, that NSPM has adequately addressed all of the regulatory requirements set forth in 10 CFR 50.55(a)3)(ii) and remains in compliance with ASME OM Code requirements.
Therefore, the NRC staff authorizes the proposed alternative request VR 05 for the fifth 10-year inservice testing interval at MNGP which began on September 1, 2012, and is currently scheduled to end on August 31, 2022. The proposed alternative shall only be utilized until completion of the MNGP spring 2015 refueling outage.
K. Fili If you have any questions, please contact Terry Beltz at (30 1) 415-3049 or via e-mail at Terry. Beltz@nrc.gov.
Sincerely, Dav1d L. Pelton, Chief Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-263
Enclosure:
Staff Evaluation of the Fifth 10-Year lnservice Inspection Interval Alternative Request No. VR 05 cc w/encl: Distribution via ListServ
~p.~ REG(/{ UNITED STATES
~-:P" ~)'o-1> NUCLEAR REGULATORY COMMISSION
<(
~
0 WASHINGTON, D.C. 20555-0001
\n ~
~ r;;
'('/.
1--? -.,o~
SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO THE FIFTH 10-YEAR INSERVICE INSPECTION PROGRAM INTERVAL REQUEST NO. VR 05 MONTICELLO NUCLEAR GENERATING PLANT NORTHERN STATES POWER COMPANY- MINNESOTA DOCKET NO. 50-263
1.0 INTRODUCTION
By letter to the U.S. Nuclear Regulatory Commission (NRC, the Commission) dated July 30, 2014 (Agencywide Documents Access and Management System (ADAMS) Accession Nos.
ML14212A071), Northern States Power Company (NSPM, the licensee). doing business as Xcel Energy, submitted alternative request VR 05 for the Monticello Nuclear Generating Plant (MNGP). The licensee requested an alternative test plan in lieu of certain inservice testing (1ST) requirements of the 2004 Edition with 2006 Addenda of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants (OM Code) for the 1ST program at MNGP during the fifth 10-year 1ST program interval, which began on September 1, 2012, and is currently scheduled to conclude on August 31, 2022.
Specifically, NSPM requested to defer its quarterly valve exercise testing on the inboard and outboard main steam line drain valves (M0-2373 and M0-2374, respectively) to the next refueling outage in spring 2015 at MNGP. Pursuant to Title 10 of the Code of Federal Regulations (1 0 CFR) Section 50.55a(a)(3)(ii), the licensee requested the use of proposed alternative VR 05 since complying with the current ASME OM Code requirements would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
The NRC staff's evaluation of the licensee's proposed alternative request is provided below.
2.0 REGULATORY EVALUATION
The regulations under 10 CFR 50.55a(f), "lnservice Testing Requirements," require, in part, that 1ST of certain ASME Code Class 1, 2, and 3 components must meet the requirements of the ASME OM Code and applicable addenda, except where alternatives have been authorized pursuant to paragraphs (a)(3)(i) or (a)(3)(ii).
Pursuant to 10 CFR 50.55a(f)(6)(i), a licensee may submit a request for relief from the given requirements, along with information to support the determination. The Commission is authorized to Enclosure
evaluate a licensee's relief request, and may grant the requested relief or impose alternative requirements, considering the burden that the licensee might incur if the Code requirements were enforced for the given facility.
Pursuant to 10 CFR 50.55a(a)(3)(i) and 10 CFR 50.55a(a)(3)(ii), the Commission may also authorize the licensee to implement an alternative to the Code requirements, provided that the alternative either provides an acceptable level of quality and safety, or compliance with the Code requirement would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
Based on the above, and pursuant to the NRC staff's findings with respect to authorizing the alternative VR 05 as given below, the NRC staff finds that regulatory authority exists for the licensee to request and the Commission to authorize the relief requested by the licensee.
MNGP is currently in its fifth 10-year 1ST program interval. The fifth 10-year 1ST program interval began on September 1, 2012, and is currently scheduled to conclude on August 31, 2022.
Finally, NSPM states in the submittal its commitment to the ASME OM Code, 2004 Edition, with Addenda through OMb Code-2006.
3.0 TECHNICAL EVALUATION
3.1 Licensee's Alternative Request VR 05 ASME OM Code Requirement ISTC-3510, "Exercising Test Frequency", states, in part, that "Active Category A, Category 8, and Category C check valves shall be exercised nominally every 3 months, except as provided by ISTC-3520, ISTC-3540, ISTC-3550, ISTC-3570, ISTC-5221, and ISTC-5222."
Alternative testing is requested for the following valves:
Table 1 Valve 10 System Category Class M0-2373 Main Steam Line Drain Valve- Inboard A 1 M0-2374 Main Steam Line Drain Valve - Outboard A 1
Reason for Request
In its July 30, 2014, submittal, the licensee provided the following reasons to support its request:
In May 2014, an upward trend in unidentified drywellleakage was identified in conjunction with an increased radiation count rate on the drywell continuous air monitor. These changes occurred during exercise (stroke time) testing of M0-2373. The licensee suspected that the increase in unidentified drywell leakage to be the result of a possible packing leak on M0-2373,
and that backseating the valve could likely reduce leakage into the drywell.
The licensee developed a backseat testing methodology to maintain the functional performance parameters of both the inboard and outboard valves within acceptable limits. On July 10, 2014, M0-2373 was backseated and testing performed to demonstrate operability of the valves. After completion of the testing on M0-2373, it was fully-opened and backseated to isolate the packing leak. The unidentified leakage in the drywell was reduced to the level that existed prior to exercising M0-2373. With M0-2373 on its backseat, M0-237 4 was closed and de-energized to prevent opening due to 10 CFR 50, Appendix R concerns.
The next quarterly valve exercise testing of M0-2373 and M0-2374 is on October 10, 2014.
The licensee is requesting to defer this quarterly testing until the next MNGP refueling outage, scheduled for the spring of 2015. Performance of the quarterly exercise testing would require multiple opening and closing evolution of the both valves, including the need to re-energize and de-energize the circuit breaker for M0-2374. Multiple opening and closing of M0-2373 has the potential to increase drywell leakage, which the backseating operation has previously restored to normal levels.
As previously discussed, quarterly exercise testing of both valves with M0-2373 on its backseat requires multiple circuit breaker manipulations. The quarterly test starts with M0-2373 being stroke timed closed. Next, the circuit breaker for M0-2374 would have to be closed to restore power to M0-2374. M0-2374 would be stroke timed open and closed, and then the circuit breaker for M0-237 4 would be reopened. M0-2373 would then be stroke-timed open and placed on its backseat to reduce unidentified drywell leakage resulting from the packing leak.
This evolution would be required to be performed each quarter (two more quarterly tests) until the refueling outage in the spring of 2015 when the valve will be repaired.
The repeated backseating of M0-2373 increases the risk of causing damage to the backseat or valve stem as described in NRC Information Notice 87-40, "Backseating Valves Routinely to Prevent Packing Leakage." Each time that a valve is placed on its backseat requires opening the circuit breaker and connecting a reduced voltage source to the motor-operated valve bypassing the open circuit until the motor is stalled. The reduced voltage source is then removed and the circuit breaker is closed. Repeatedly performing this evolution increases the potential for human errors to occur. Motor damage could also occur if the locked-rotor current is in excess of 15 seconds. If reduced voltage is not properly controlled during the evolution, then the valve backseat or stem may be damaged. Finally, an increase in unidentified drywell leakage, such as might occur from repeated cycling of M0-2373, could ultimately result in a Technical Specification required shutdown.
In NUREG 1482, "Guidelines for lnservice Testing at Nuclear Power Plants: lnservice Testing of Pumps and Valves and lnservice Examination and Testing of Dynamic Restraints (Snubbers) at Nuclear Power Plants- Final Report," Revision 2, Section 3.1.1, it states that a licensee may request relief from quarterly testing where such testing would impose a hardship, such as entering a limiting condition for operations of 3 to 4 hours0.167 days <br />0.0238 weeks <br />0.00548 months <br /> in duration or repositioning a circuit breaker from "off' to "on." Other acceptable reasons for relief include the need to keep personnel radiation exposure as low as reasonably achievable (ALARA), and personnel safety.
Repair of M0-2373 valve packing would require entry into the drywell (i.e., primary containme.nt). Entry into the drywell requires the plant to either enter Mode 3 (Hot Shutdown) or
reduce reactor power below 10 percent to minimize radiation levels. Personnel entry into the drywell with the plant at operation is increases risk due to radiation exposure and does not support the practice of maintaining ALARA. Drywell entry presents a personnel safety concern due to high ambient temperatures, and it is typically inaccessible during normal power operation due to being inerted with nitrogen gas.
Additionally, maneuvering the reactor to below 10 percent power or into Mode 3 involves an inherent risk and increases the nuclear safety risks due to cycling plant equipment. The licensee states that maintaining the packing leak isolated with the M0-2373 backseated in the open position and M0-2374 closed is the lower risk option.
For all of these reasons, NSPM states that with the current plant configuration the quarterly exercise testing of M0-2373 and M0-237 4 involves a hardship. There is not a sufficient corresponding increase in the level of safety versus the potential to increase drywell unidentified leakage or cause further damage to M0-2373.
Proposed Alternative The main steam line drain valves are exercise tested quarterly: The present configuration of having M0-2373 backseated in the open position to decrease drywell leakage, and closing and de-energizing M0-2374 to isolate the containment penetration, is a temporary configuration.
Quarterly exercise testing of the M0-2373 from the backseated position increases vulnerability of having unacceptable drywell leakage, for which the backseating operation was previously performed and which reduced drywell leakage to acceptable levels.
NSPM proposes to stroke M0-2373 and M0-2374 during the next MNGP refueling outage in lieu of the current quarterly exercise testing. Both valves have successfully passed each quarterly exercise test since plant startup from the 2013 refueling outage. Historical exercise trending results for both valves for performances prior to the 2013 refueling outage are consistent with current cycle results.
Both M0-2373 and M0-2374 are normally closed during power operation. The valves safety function is to close to prevent inventory loss following a main steam line pipe break outside containment and to provide containment isolation. The proposed operating configuration for the remainder of the cycle maintains the required safety function of containment isolation. Multiple backseating evolutions of M0-2373 could potentially result in either backseat or stem damage, and quarterly exercise testing unnecessarily challenges this safety function. Also, since both valves are normally closed during power operation, there are no operational reasons to require stroking of these valves during this period.
NSPM requests to extend the exercise testing due to the hardship without a compensating increase in the level of quality and safety presented by the temporary configuration of the main steam line drain valves. There is reasonable assurance that these valves will perform their safety function to close to prevent inventory loss following main steam line pipe breaks outside containment and to provide containment isolation. The proposed alternative identified in this relief request shall be utilized until the next MNGP refueling outage in spring of 2015.
3.2 NRC Staff Evaluation ASME OM Code requirement ISTC-3510 requires that active Category A and B valves be exercised nominally every three months. In addition, the ASME OM Code specifies that if the exercise tests are not practicable to perform during power operation, the test may be deferred to either cold shutdowns or refueling outages.
The licensee has been exercise testing the valves noted in Table 1 nominally every three months. However, following the exercise testing completed in May 2014, there was a noted increase in drywall unidentified leakage due to possible valve packing leakage from M0-2373.
Continued operation of M0-2373 in its normally closed position could mask or potentially challenge the technical specification acceptance criteria for reactor coolant system operational leakage associated with unidentified leakage. Repair of the valve packing would require the plant either reduce reactor power or enter Mode 3.
To preclude a potential plant power reduction or shutdown, the licensee electrically backseated M0-2373 to seal off the packing area, operationally tested it from this configuration, and then re-opened it on the backseat. Unidentified leakage in the drywall returned to expected levels, thus supporting the most likely source of the increased leakage to be from M0-2373 packing.
Continuation with quarterly exercise testing and maintaining a normally closed valve position could result in an unnecessary plant shutdown which is considered an impractical condition as noted in NUREG-1482 Revision 2, Section 2.4.5. Continuation with the quarterly valve exercise testing and returning the faulty valve to a backseated configuration requires several special valve stroke manipulations at the motor control center. This represents an additional hardship or unusual difficulty without a compensating increase in the level of quality or safety.
The licensee proposes to maintain the current configuration of maintaining M0-2374 in the closed (i.e., safety) position with the valve motor electrically de-energized, and with M0-2373 in the full-open and backseated position with electrical power provided to maintain isolation capability on receipt of an automatic close signal. This configuration will be maintained until maintenance can be performed at the next refueling outage, currently scheduled for the spring of 2015.
The NRC staff finds that the proposed alternative is within the ASME OM Code guidelines for deferring impractical exercise testing to the refueling outage and provides reasonable assurance that the components remain operationally ready.
4.0 CONCLUSION
As set forth above, the NRC staff determines that the proposed alternative described in alternative request VR 05 provides reasonable assurance that valves listed in Table 1 are operationally ready. Accordingly, the staff concludes that the licensee has adequately addressed all of the regulatory requirements set forth in 10 CFR 50.55a(a)(3)(ii), and is in compliance with the ASME OM Code requirements. Therefore, the NRC staff authorizes the proposed alternative in request VR 05 at MNGP for the fifth 1ST interval which began on September 1, 2012, and is currently scheduled to end on August 31, 2022. The proposed alternative is only authorized until completion of the MNGP spring 2015 refueling outage.
All other ASME OM Code requirements for which relief was not specifically requested and approved in the subject request for relief remain applicable.
Principle Contributor: Michael Farnan, NRR Date of issuance: August 2 7, 2014
K. Fili If you have any questions, please contact Terry Beltz at (301) 415-3049 or via e-mail at Terry.Beltz@nrc.gov.
Sincerely, IRA/
David L. Pelton, Chief Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-263
Enclosure:
Staff Evaluation of the Fifth 10-Year lnservice Inspection Interval Alternative Request No. VR 05 cc w/encl: Distribution via ListServ DISTRIBUTION:
PUBLIC LPL3-1 R/F TBowers, EDO R-Ill RidsNrrDorllpl3-1 Resource RidsNrrDeEpnb Resource DAiley, NRR RidsAcrsAcnw_MaiiCTR Resource RidsNrrDoriDpr Resource MFarnan, NRR RidsNrrPMMonticeilo Resource RidsRgn3Mai1Center Resource RidsNrrLAMHenderson Resource ADAMS A ccesston No.: ML14223A581
- v1a e-ma1*1 d ate d A ugust7,2 0 14 0
OFFICE LPL3-1/PM LPL3-1/LA EPNB/BC LPL3-1/BC NAME TBeltz MHenderson DAiley* DPelton DATE 08/14/2014 08/13/2014 08/07/2014 08/27/2014 OFFICIAL RECORD COPY