RA-14-041, Annual Radioactive Effluent Release Report 2013

From kanterella
(Redirected from ML14143A092)
Jump to navigation Jump to search
Annual Radioactive Effluent Release Report 2013
ML14143A092
Person / Time
Site: Oyster Creek
Issue date: 05/01/2014
From: Stathes G
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
RA-14-041
Download: ML14143A092 (110)


Text

n ti 10 CFR 50.36a(a)(2) 10 CFR 72.44 (d)(3)

Technical Specification 6.9.1.d RA-14041 May 1, 2014 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 - 0001 Oyster Creek Nuclear Generating Station Renewed Facility Operating License No. DPR-16 NRC Docket No. 50-219 Independent Spent Fuel Storage Facllity NRC Docket No. 72-15 Subject Annual Radioactive Effluent Release Report for 2013 Enclosed with this cover letter is the Annual Radioactive Effluent Release Report for the period January 1 to December 31, 2013. This report includes the Oyster Creek Nuclear Generating Station Independent Spent Fuel Storage Facmty.

If any further information or assistance is needed, please contact John Renda, Chemistry Manager, at 609-971-2572.

~yj Garey I:. es Vice President -Oyster Creek Nuclear Generating Station

Enclosure:

2013 Annual Radioactive Effluent Release Report cc: Administrator, USNRC Region I {w/o USNRC Senior Project Manager, Oyster Creek (w/o attachment)

USNRC Senior Resident Inspector, Oyster Creek (w/o attachment)

Craig Stewart, American Nuclear insurers

Annual Radioactive Effluent Release Report 2013 Oyster Creek Generating Station

Oyster Creek 2013 Annual Radioactive Effluent Release Report ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1, 2013 through December 31, 2013 EXELON GENERATION COMPANY, LLC OYSTER CREEK GENERATING STATION DOCKET NO. 50-219 (Oyster Creek Generating Station)

DOCKET NO. 72-15 (Independent Spent Fuel Storage Facility)

Submitted to The United States Nuclear Regulatory Commission Pursuant to Renewed Facility Operating License DPR-16

Oyster Creek 2013 Annual Radioactive Effluent Release Report TABLE OF CONTENTS SECTION PAGE EXECUTIVE

SUMMARY

1

1. Introduction 3
2. Supplemental Information 4 A Regulatory Limits 4 B Effluent Concentration Limits 5 C Average Energy 5 D Measurements and Approximations of Total Radioactivity 5 E Batch Releases 9 F Abnormal Releases 9 G Revisions to the ODCM 9 H Radiation Effluent Monitors Out of Service More Than 30 Days 10 I Releases from the Independent Spent Fuel Storage Facility 10 J Program Deviations 10 Appendix A - Effluent and Waste Disposal Summary 11 Appendix B - Solid Waste and Irradiated Fuel Shipments 18 Appendix C - Radiological Impact to Man 23 Appendix D - Meteorological Data 26 Appendix E - ODCM Revisions 100 Appendix F - ERRATA 101 ii

Oyster Creek 2013 Annual Radioactive Effluent Release Report (Page Intentionally Left Blank) iii

Oyster Creek 2013 Annual Radioactive Effluent Release Report EXECUTIVE

SUMMARY

Effluents are strictly monitored to ensure that radioactivity released to the environment is as low as reasonably achievable and does not exceed regulatory limits. Effluent control includes the operation of monitoring systems, in-plant and environmental sampling and analyses programs, quality assurance programs for the effluent and environmental programs, and procedures covering all aspects of effluent and environmental monitoring.

Both radiological environmental and effluent monitoring indicate that the operation of Oyster Creek Generating Station (OCGS) does not result in significant radiation exposure to the people or the environment surrounding OCGS and is well below the applicable levels set by the Nuclear Regulatory Commission (NRC) and the Environmental Protection Agency (EPA).

There were liquid radioactive effluent releases during 2013 of concentrations of tritium too low to detect at an LLD of 200 picocuries per liter (pCi/L) at the New Jersey Pollution Discharge Elimination System (NJPDES) permitted main condenser outfall. The releases were part of nearly continuous pumping of groundwater at approximately 70 gpm containing low levels of tritium and no detectable gamma. Exelon and the State of New Jersey Department of Environmental Protection (NJDEP) agreed to this remediation action instead of natural attenuation to address concentrations of tritium in groundwater. Well 73 and supporting equipment and piping were installed to pump groundwater to the intake structure at the inlet of the main circulating water pumps. Provisions were established for both batch and continuous releases of groundwater. Continuous releases occurred approximately 361 days in 2013. The Continuous releases occurred from January 1, 2013 through December 27, 2013 with a total of 3.50E+07 gallons of groundwater pumped resulting in 2.82E-01 Ci of tritium released to the discharge canal. The dose to the most limiting member of the public due to the release of groundwater was 1.37E-06 mrem.

There were no liquid abnormal releases during 2013.

There was one gaseous abnormal release during 2013. During the annual inspection of the Old Radwaste Building exhaust fan connections to the main stack it was discovered that there were three slits in the top boot connection of exhaust fan EF-1-16 and a bolt missing in the connection of exhaust fan EF-1-17.

The maximum calculated organ dose (Bone) from iodines, tritium, carbon-14 (C-14), and particulates to any individual due to gaseous effluents was 4.93E-01 mrem, which was approximately 3.29E+00 percent of the annual limit of 15 mrem. The majority of organ dose from gaseous effluents was due to C-14. The maximum calculated gamma air dose in the UNRESTRICTED AREA due to noble gas effluents was 3.60E-03 mrad, which was 3.60E-02 percent of the annual 10 CFR 50 Appendix I, As Low As Reasonably Achievable (ALARA) limit of 10 mrad.

For comparison, the background radiation dose averages approximately 300 mrem per year in the Central New Jersey area, which includes approximately 200 mrem from naturally occurring radon gas and 100 mrem from background radiation.

The Independent Spent Fuel Storage Installation (ISFSI) is a closed system and the only exposure is due to direct radiation. Based on offsite TLD readings, dose due to direct radiation from the 1

Oyster Creek 2013 Annual Radioactive Effluent Release Report ISFSI was less than 1 mrem for 2013. Because it is a sealed unit, no radioactive material was released.

Comparison of environmental sampling results to iodine and particulate gaseous effluents released, showed no radioactivity attributable to the operation of OCGS. Both elevated and ground-level release paths were considered in this review, with total iodines released of 3.12E-03 Ci and total particulates with half-lives greater than 8 days less C-14 released of 3.82E-02 Ci.

Joint Frequency Tables of meteorological data, per Stability Classification Category, as well as for all stability classes, are included. All data was collected from the on-site Meteorological Facility. Data recoveries for the 380-foot data and the 33-foot data were 99.4 percent and 99.4 percent, respectively. The UFSAR commits to Regulatory Guide (RG) 1.23 for Meteorological Facility data recovery. RG 1.23 requires data recovery of at least 90% on an annual basis.

2

Oyster Creek 2013 Annual Radioactive Effluent Release Report 1 Introduction In accordance with the reporting requirements of Technical Specification 6.9.1.d applicable during the reporting period, this report summarizes the effluent release data for OCGS for the period January 1, 2013 through December 31, 2013. This submittal complies with the format described in Regulatory Guide 1.21, "Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants", Revision 1, June 1974.

Meteorological data was reported in the format specified in Regulatory Guide 1.23, Revision 1, "Meteorological Monitoring Programs for Nuclear Power Plants".

All vendor results were received and included in the report calculations. Therefore the 2013 report is complete.

3

Oyster Creek 2013 Annual Radioactive Effluent Release Report 2 Supplemental Information Oyster Creek Generating Station Exelon Generation Company, LLC A. Regulatory Limits:

Limit Units Receptor ODCM and 10 CFR 50, Appendix I Design Objective Limits

1. Noble Gases:
a. < 500 mrem/yr Total Body ODCM Control 3.11.2.1

< 3000 mrem/yr Skin

b. <5 mrad Air Gamma Quarterly air dose limits

< 10 mrad Air Beta ODCM Control 3.11.2.2

c. < 10 mrad Air Gamma Yearly air dose limits

< 20 mrad Air Beta ODCM Control 3.11.2.2

d. <5 mrem Total Body 10 CFR 50, Appendix I, (Gamma) Section II.B.2(b)

< 15 mrem Skin (Beta)

2. Iodines, Tritium, Particulates with Half Life > 8 days:
a. < 1500 mrem/yr Any Organ ODCM Control 3.11.2.1
b. < 7.5 mrem Any Organ Quarterly dose limits ODCM Control 3.11.2.3
c. < 15 mrem Any Organ Yearly dose limits ODCM Control 3.11.2.3
3. Liquid Effluents
a. Concentration 10 CFR 20, Appendix B, ODCM Control 3.11.1.1 Table 2 Column 2
b. < 1.5 mrem Total Body Quarterly dose limits

<5 mrem Any Organ ODCM Control 3.11.1.2

c. <3 mrem Total Body Yearly dose limits

< 10 mrem Any Organ ODCM Control 3.11.1.2 4

Oyster Creek 2013 Annual Radioactive Effluent Release Report B. Effluent Concentration Limits:

Gaseous dose rates rather than effluent concentrations are used to calculate permissible release rates for gaseous releases. The maximum permissible dose rates for gaseous releases are defined in ODCM Controls 3.11.2.1.

The Effluent Concentration Limit (ECL) specified in 10 CFR 20, Appendix B, Table 2, Column 2 for identified nuclides, were used to calculate permissible release rates and concentrations for liquid release per ODCM Controls 3.11.1.1. The total activity concentration at the Route 9 bridge for all dissolved or entrained gases was limited to < 2E-04 Ci/ml.

C. Average Energy ( E ):

The Oyster Creek ODCM limits the instantaneous dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The average beta and gamma energies ( E ) of the radionuclide mixture in releases of fission and activation gases as described in Regulatory Guide 1.21, "Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plant", may be used to calculate doses in lieu of more sophisticated software. The Oyster Creek radioactive effluent program employs the methodologies presented in U.S. NRC Regulatory Guide 1.109 "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977. Therefore, average energy

( E ) as described in Regulatory Guide 1.21 is not applicable to Oyster Creek.

D. Measurements and Approximations of Total Radioactivity:

1. Fission and Activation Gases The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a gas Marinelli beaker. Airborne effluent gaseous activity was continuously monitored and recorded in accordance with the Off Site Dose Calculation Manual (ODCM) Table 4.11.2.1.2-1. Additional grab samples were taken from the stack Radioactive and Gaseous Effluent Monitoring System (RAGEMS) sample point and ground-level release sample points and analyzed at least monthly to determine the isotopic mixture of noble gas activity released for the month. If activity was found in the grab isotopic analysis, the results are entered into Simplified Environmental Effluent Dosimetry System (SEEDS) to calculate dose and dose rates. If no activity is detected in the stack grab samples, post treatment or Off Gas Isotopic Analysis data may be used.
2. Iodines The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a charcoal cartridge. Iodine activity was continuously sampled and analyzed in accordance with ODCM Table 4.11.2.1.2-1.

Charcoal samples are taken from the stack RAGEMS sample point and 5

Oyster Creek 2013 Annual Radioactive Effluent Release Report ground-level release sample points and analyzed at least weekly to determine the total activity released from the plant based on the average vent flow rates recorded for the sampling period.

3. Particulates (half-lives > 8 days)

The method used for Gamma Isotopic Analysis is the Canberra Gamma Spectroscopy System with a particulate filter (47 mm). Particulate activity was continuously sampled and analyzed in accordance with ODCM Table 4.11.2.1.2-1. Particulate samples are taken from the stack RAGEMS sample point and ground-level release sample points and analyzed at least weekly to determine the total activity released from the plant based on the average vent flow rates recorded for the sampling period.

4. Tritium A. Gaseous Effluents Air from stack and vent effluents was passed through a desiccant column and distilled to remove the moisture collected. An aliquot of the water from the distillate was analyzed for tritium using a liquid scintillation counter.

B. Liquid Effluents Water from liquid effluents was analyzed for tritium using a liquid scintillation counter.

5. Gross Alpha Gross alpha was measured by an off-site vendor for both the gas and liquid effluent composite samples.
6. Hard-To-Detects Hard-To-Detects was measured by an off-site vendor for one set of gas monthly composites. The analysis included Fe-55, I-129, Ni-59, Ni-63, Tc-99, Am-241, Cm-242, Cm-243/244, Pu-238, Pu-239/240 and Pu241.

Fe-55 and Ni-63 have been added to the routine monthly composite analysis schedule based on previous sample results for Hard-To-Detects.

6

Oyster Creek 2013 Annual Radioactive Effluent Release Report

7. Carbon-14 (C-14)

The amount of C-14 (Ci) released was estimated using the guidance from EPRI Technical Report 1021106, Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents. The C-14 was released primarily through the stack (97%) with a small amount (3%) released through plant vents. The activity in liquid effluents was determined to not be significant.

The offsite dose from C-14 was calculated using SEEDS, which uses approved ODCM methodologies. The resulting annual dose to a child from gaseous releases of C-14 is about 4.67E-01 mrem to the bone.

8. Liquid Effluents Groundwater containing tritium was released during 2013. For continuous releases, tritium and principal gamma emitters were determined for a composite sample daily. The concentration of tritium is limited to ensure concentrations were less than 200 pCi/l in the discharge canal. The gamma emitters were limited to less than detectable concentrations. Gross alpha and Hard-to-detect analyses (Fe-55, Ni-63, Sr-89 and Sr-90) were determined for monthly composite samples for each type of release (batch or continuous).

The leaks into the groundwater were reported in the 2009 Annual Radioactive Effluent Release Report as abnormal releases. Estimates of the curies of the tritium releases were reported. Doses due to the release of the groundwater to the discharge canal were included in the report. To ensure that amount of activity discharge is accurate and limiting, the activity and doses as a result of discharges during 2013 from the groundwater remediation project are included in this report.

9. Estimated Total Error Present Procedure CY-AA-170-2100, Estimated Errors of Effluent Measurements, provides the methodology to obtain an overall estimate of the error associated with radioactive effluents.

7

Oyster Creek 2013 Annual Radioactive Effluent Release Report

10. Composite Samples and Lower Limit of Detection (LLD)

Particulate air samples were composited monthly and analyzed for gross alpha, Sr-89, Sr-90, Fe-55 and Ni-63. Groundwater batch and continuous releases were composited at least monthly and analyzed for gross alpha, Sr-89, Sr-90, Fe-55 and Ni-63. These composites are submitted to an offsite vendor laboratory for analysis. The ODCM required LLD for liquid and airborne releases are as follows:

Liquid: LLD Principal Gamma Emitters (Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, I-131, Ce-141, Cs-134, Cs-137) 5E-07 µCi/ml Principal Gamma Emitters (Ce-144) 5E-06 µCi/ml Dissolved and Entrained Gases 1E-05 µCi/ml H-3 1E-05 µCi/ml Gross Alpha 1E-07 µCi/ml Sr-89 and Sr-90 5E-08 µCi/ml Fe-55 and Ni-63 1E-06 µCi/ml Airborne LLD Principal Gamma Emitters (Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-138) 1E-04 µCi/ml H-3 1E-06 µCi/ml I-131 1E-12 µCi/ml I-133 1E-10 µCi/ml Principal Gamma Emitters (Mn-54, Fe-59, Co-58, Co-60, Zn-65, Cs-134, Cs-137, Ce-141) 1E-11 µCi/ml Principal Gamma Emitters (Mo-99, Ce-144) 1E-10 µCi/ml Gross Alpha 1E-11 µCi/ml Sr-89, Sr-90 1E-11 µCi/ml 8

Oyster Creek 2013 Annual Radioactive Effluent Release Report E. Batch Releases:

1. Liquid There were no batch releases of liquid effluents during 2013.
2. Gaseous There were no batch releases of gaseous effluents during 2013.

F. Abnormal Releases:

There were no abnormal liquid releases during 2013.

There was one abnormal gaseous release during 2013. During the performance of Work Order R2205683, which is to perform an annual inspection of the stack pad exhaust fans, three slits were discovered in the top boot of exhaust fan EF-1-16 and a bolt was missing from exhaust fan EF-1-17. These are the two exhaust fans for the Old Radwaste Building to the Main Stack. One of these two exhaust fans is in operation at all times to maintain a negative pressure in the Old Radwaste Building.

At no times do both of these fans run simultaneously as each fans is designed to provide 100% of the required flow. Engineering performed a calculation to determine a release rate that encompasses the maximum release rate regardless of which exhaust fan is in service. The activity to inspect the exhaust fans is an annual activity.

The following assumptions were made when calculating Curies released and dose:

Both exhaust fans have been leaking since the date of the last inspection until the time of the last repair, 7/29/12 through 7/25/13.

All of the activity due to particulates reported from the Main Stack was coming from the Old Radwaste Building and therefore being released as a groundlevel release from the exhaust fan leaks at the flow rate calculated by Engineering.

Quarter Quarter Quarter Units Quarter 4 1 2 3 Total Release Ci 4.94E-05 5.00E-05 1.37E-05 0.00E+00 G. Revisions to the ODCM:

There were no revisions to the ODCM during 2013.

9

Oyster Creek 2013 Annual Radioactive Effluent Release Report H. Radiation Effluent Monitors Out of Service More Than 30 Days Per ODCM Control 3.3.3.10, "Radioactive Liquid Effluent Monitoring Instrumentation" and 3.3.3.11, Radioactive Gaseous Effluent Monitoring Instrumentation requires:

With less than the minimum number of radioactive liquid/gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3.3.3.10-1/3.3.3.11-1. Make every reasonable effort to return the instrument to OPERABLE status within 30 days and, if unsuccessful, explain in the next Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner.

The following is a discussion of instrumentation out of service for greater than 30 days:

1. The Offgas Building Exhaust Gaseous Effluent Radioactive Noble Gas Monitor was out of service from 5/20/2013 through 8/9/2013. The monitor was taken out of service 5/20/2013 for failing the monitor functional test The original issue for the monitor failing the functional test was a faulty pushbutton on the alarm panel causing the alarm not to function. Parts were ordered and replaced on 6/18/2013 but the alarm still did not function as expected. After multiple troubleshooting attempts it was determined that the annunciator window card wiring was the issue. After changing the wiring in the alarm panel, all alarms responded as expected. The functional test was reperformed 8/9/2013 satisfactorily and the monitor was returned to service. This issue was entered into our Corrective Action Program (CAP) and corrective actions taken have been documented per process. All ODCM required compensatory measures were met.

I. Releases from the Independent Spent Fuel Storage Facility:

The ISFSI is a closed system and the only exposure would be due to direct radiation. This includes iodines, particulates, and noble gases. Based on offsite TLD readings, dose due to direct radiation from the ISFSI was less than 1 mrem for 2013. Because it is a sealed unit, no radioactive material was released.

J. Program Deviations:

1. The groundwater remediation composite sampler was found with no composite collected on December 27, 2013. The composite sampler is required by ODCM Table 4.11.1.1.1-1, Radioactive Liquid Waste Sampling and Analysis Program. A manual sample was obtained per SP 10-003.

Operations department was notified that composite sampler was not working and Operations secured discharging from W-73 and Chemistry secured the composite sampler. This issue was entered into our Corrective Action Program (CAP) and corrective actions taken have been documented per process.

10

Oyster Creek 2013 Annual Radioactive Effluent Release Report Appendix A Effluent and Waste Disposal Summary 11

Oyster Creek 2013 Annual Radioactive Effluent Release Report LIST OF TABLES PAGE Table A - 1 Gaseous Effluents - Summary of All Releases 13 Table A - 2 Gaseous Effluents Release Point: Elevated Release 14 Table A - 3 Gaseous Effluents Release Point: Ground Level Releases 15 Table A - 4 Liquid Effluents - Summary of All Releases 16 Table A - 5 Liquid Release Point: Groundwater Remediation 17 12

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table A-1: Gaseous Effluents - Summary Of All Releases Period: January 1, 2013 through December 31, 2013 Unit: Oyster Creek Est. Total A. Fission & Activation Gases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %

1. Total Release Ci 2.06E+01 1.40E+01 7.04E+00 8.02E+00 25.00%
2. Average Release Rate for Period Ci/sec 2.62E+00 1.79E+00 8.85E-01 1.01E+00
3. Gamma Air Dose mrad 2.60E-03 1.13E-03 3.99E-04 8.36E-04
4. Beta Air Dose mrad 1.87E-04 6.44E-04 2.77E-04 2.79E-04
5. Percent of ODCM Limit

- Gamma Air Dose  % 5.20E-02 2.26E-02 7.98E-03 1.67E-02

- Beta Air Dose  % 1.87E-03 6.44E-03 2.77E-03 2.79E-03 B. Iodines

1. Total - I-131 Ci 3.78E-04 1.27E-04 2.57E-04 5.94E-04 25.00%
2. Average Release Rate for Period Ci/sec 4.81E-05 1.62E-05 3.23E-05 7.47E-05
3. Percent of ODCM limit  % * * *
  • C. Particulate
1. Particulates with T 1/2 > 8 days Ci 1.32E-02 7.61E-03 8.44E-03 8.97E-03 25.00%
2. Average Release Rate for Period Ci/sec 1.69E-03 9.67E-04 1.06E-03 1.13E-03
3. Percent of ODCM limit  % * * *
1. Total Release Ci 8.78E+00 6.40E+00 3.89E+00 5.82E+00 25.00%
2. Average Release Rate for Period Ci/sec 1.12E+00 8.14E-01 4.90E-01 7.32E-01
3. Percent of ODCM limit  % * * *
  • E. Gross Alpha
1. Total Release Ci <LLD <LLD <LLD <LLD 25.00%
2. Average Release Rate for Period Ci/sec <LLD <LLD <LLD <LLD
3. Percent of ODCM limit  % * * *
1. Total Release Ci 2.46E+00 2.49E+00 2.53E+00 2.53E+00
2. Average Release Rate for Period Ci/sec 3.13E-01 3.17E-01 3.18E-01 3.18E-01
3. Percent of ODCM limit  % * * *
1. Organ Dose mrem 5.00E-02 1.40E-01 1.64E-01 1.49E-01
2. Percent of ODCM Limit  % 6.67E-01 1.87E+00 2.19E+00 1.99E+00

13

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table A-2: Gaseous Effluents Release Point: Elevated Release Period: January 1, 2013 through December 31, 2013 Unit: Oyster Creek Nuclides Released Continuous Mode Batch Mode

1. Fission gases Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Kr- 85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr- 85m Ci 1.74E-01 4.12E-01 <LLD 9.02E-02 <LLD <LLD <LLD <LLD Kr-87 Ci 2.33E-01 2.13E+00 9.60E-01 2.44E+00 <LLD <LLD <LLD <LLD Kr-88 Ci 8.48E+00 4.43E+00 6.66E-01 5.43E-01 <LLD <LLD <LLD <LLD Xe-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Ci 1.17E+01 7.07E+00 5.41E+00 3.57E+00 <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-137 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD 1.38E+00 <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 2.06E+01 1.40E+01 7.04E+00 8.02E+00 <LLD <LLD <LLD <LLD
2. Iodines I-131 Ci 3.78E-04 1.27E-04 2.57E-04 5.93E-04 <LLD <LLD <LLD <LLD I-133 Ci 4.02E-04 1.84E-04 4.03E-04 7.74E-04 <LLD <LLD <LLD <LLD I-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 7.80E-04 3.11E-04 6.60E-04 1.37E-03 <LLD <LLD <LLD <LLD
3. Particulates Sr-89 Ci 2.26E-03 4.15E-04 1.95E-04 5.99E-04 <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci 2.82E-04 3.93E-05 1.52E-04 <LLD <LLD <LLD <LLD <LLD Ba-140 Ci 3.61E-03 3.72E-04 4.66E-04 6.93E-04 <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD 8.81E-05 5.42E-04 <LLD <LLD <LLD <LLD Mn-54 Ci 9.47E-04 6.49E-04 5.84E-04 1.01E-03 <LLD <LLD <LLD <LLD Co-58 Ci 2.11E-03 2.28E-03 2.44E-03 2.03E-03 <LLD <LLD <LLD <LLD Co-60 Ci 2.55E-03 2.95E-03 3.45E-03 2.81E-03 <LLD <LLD <LLD <LLD Ni-63 Ci 3.50E-04 <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci 1.48E-04 1.67E-04 1.84E-04 1.57E-04 <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-55 Ci 3.67E-04 <LLD <LLD 3.22E-04 <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci 5.42E-04 6.52E-04 8.51E-04 7.01E-04 <LLD <LLD <LLD <LLD Total for Period Ci 1.32E-02 7.52E-03 8.41E-03 8.86E-03 <LLD <LLD <LLD <LLD
4. Tritium H-3 Ci 8.49E+00 6.28E+00 3.60E+00 5.61E+00 <LLD <LLD <LLD <LLD
5. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD
6. Carbon-14 C-14 Ci 2.39E+00 2.42E+00 2.45E+00 2.45E+00 <LLD <LLD <LLD <LLD 14

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table A-3: Gaseous Effluent Release Point: Ground Level Releases Period: January 1, 2013 through December 31, 2013 Unit: Oyster Creek Nuclides Released Continuous Mode Batch Mode

1. Fission gasesUnit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Kr- 85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr- 85m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-133m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD
2. Iodines I-131 Ci 9.94E-08 <LLD 3.73E-08 8.18E-07 <LLD <LLD <LLD <LLD I-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD I-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 9.94E-08 <LLD 3.73E-08 8.18E-07 <LLD <LLD <LLD <LLD
3. Particulates Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci 2.57E-07 2.59E-07 7.13E-08 <LLD <LLD <LLD <LLD <LLD Ba-140 Ci 2.62E-05 2.65E-05 7.28E-06 <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci 5.30E-06 5.35E-06 1.47E-06 <LLD <LLD <LLD <LLD <LLD Mn-54 Ci 4.78E-06 5.64E-06 1.22E-06 1.80E-05 <LLD <LLD <LLD <LLD Co-58 Ci 3.86E-06 1.33E-05 4.02E-06 3.51E-07 <LLD <LLD <LLD <LLD Co-60 Ci 1.17E-05 2.86E-05 1.69E-05 8.87E-05 <LLD <LLD <LLD <LLD Ni-63 Ci 2.74E-05 <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci 7.96E-07 8.05E-07 2.21E-07 <LLD <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-55 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci 2.09E-06 2.11E-06 5.81E-07 <LLD <LLD <LLD <LLD <LLD Am-241 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 8.24E-05 8.26E-05 3.18E-05 1.07E-04 <LLD <LLD <LLD <LLD
4. Tritium H-3 Ci 2.88E-01 1.22E-01 2.93E-01 2.05E-01 <LLD <LLD <LLD <LLD
5. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD
6. Carbon-14 C-14 Ci 7.40E-02 7.49E-02 7.57E-02 7.57E-02 <LLD <LLD <LLD <LLD 15

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table A-4: Liquid Effluents - Summary Of All Releases Period: January 1, 2013 through December 31, 2013 Unit: Oyster Creek Est. Total A. Fission & Activation Products Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %

1. Total Release not including 25.00%

Ci <LLD <LLD <LLD <LLD tritium, gases, alpha

2. Average Diluted concentration Ci/ml <LLD <LLD <LLD <LLD during period
3. Total Body Dose mrem 4.05E-07 3.30E-07 3.28E-07 3.08E-07
4. Organ Dose mrem 4.05E-07 3.30E-07 3.28E-07 3.08E-07
3. Percent of ODCM Limit

-Total Body Dose  % 2.70E-05 2.20E-05 2.19E-05 2.05E-05

-Organ Dose  % 8.10E-06 6.60E-06 6.57E-06 6.16E-06 B. Tritium Est. Total Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %

1. Total Release Ci 8.42E-02 7.04E-02 6.88E-02 5.84E-02 25.00%
2. Average diluted concentration Ci/ml 1.80E-10 1.45E-10 1.42E-10 1.30E-10 during period
3. Percent of 10CFR20 limit  % 1.80E-05 1.45E-05 1.42E-05 1.30E-05 C. Dissolved and Entrained Gases Est. Total Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
1. Total Release Ci <LLD <LLD <LLD <LLD 25.00%
2. Average diluted concentration Ci/ml <LLD <LLD <LLD <LLD
3. Percent of ODCM limit  % <LLD <LLD <LLD <LLD D. Gross Alpha Activity Est. Total Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
1. Total Release Ci <LLD <LLD <LLD <LLD 25.00%

E. Volume of Waste Released prior to dilution Liters 3.48E+07 3.44E+07 3.42E+07 2.89E+07 F. Volume of Dilution Water Used During Period Liters 4.69E+11 4.85E+11 4.85E+11 4.48E+11 16

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table A-5: Liquid Release Point: Groundwater Remediation Period: January 1, 2013 through December 31, 2013 Unit: Oyster Creek Nuclides Released Continuous Mode Batch Mode Fission & Unit Activation Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter Products 1 2 3 4 1 2 3 4 Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD I-131 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-60 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ni-63 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mn-54 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zr-95 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Nb-95 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Tc-99m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-55 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Dissolved Entrained Gases Xe-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Tritium H-3 Ci 8.42E-02 7.04E-02 6.88E-02 5.84E-02 <LLD <LLD <LLD <LLD Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 17

Oyster Creek 2013 Annual Radioactive Effluent Release Report Appendix B Solid Waste and Irradiated Fuel Shipments 18

Oyster Creek 2013 Annual Radioactive Effluent Release Report A. Solid waste shipped offsite for burial or disposal (not irradiated fuel)

1. Type of waste Types of Waste Total Total Period Est. Total Quantity Activity Error%

(m3 ) (Ci)

a. Spent resins,filter sludges, evaporator bottom, etc 6.20E+01 2.15E+02 2013 2.50E+01
b. Dry compressible waste, contaminated equip, etc 2.37E+02 6.48E-02 2013 2.50E+01
c. Irradiated components, control rods,etc 0.00E+00 0.00E+00 2013 2.50E+01
d. Other 1.32E+02 4.30E-02 2013 2.50E+01 19

Oyster Creek 2013 Annual Radioactive Effluent Release Report

1. Estimate of Major Nuclide Composition (By Waste Type)

Category A - Spent Resin, Filters, Sludges, Evaporator Bottoms, etc.

Isotope Waste Class A Waste Class B Curies Percent Curies Percent H-3 4.10E-02 9.35E-02 3.14E-03 1.84E-03 C-14 1.01E-01 2.30E-01 2.71E-02 1.59E-02 Cr-51 P-32 2.02E-06 4.61E-06 1.30E-10 7.62E-11 Mn-54 3.85E+00 8.78E+00 3.01E+00 1.76E+00 Fe-55 2.22E+01 5.06E+01 1.07E+02 6.27E+01 Fe-59 Co-57 2.96E-03 6.75E-03 Co-58 1.83E-01 4.17E-01 5.74E-03 3.36E-03 Co-60 1.42E+01 3.24E+01 3.89E+01 2.28E+01 Ni-59 2.83E-03 1.66E-03 Ni-63 2.78E-01 6.34E-01 1.92E+00 1.13E+00 Zn-65 8.55E-01 1.95E+00 1.27E+00 7.44E-01 Sr-89 2.87E-04 6.54E-04 1.42E-05 8.32E-06 Sr-90 8.44E-03 1.92E-02 8.95E-02 5.25E-02 Nb-95 Tc-99 8.01E-03 4.69E-03 Ag-110m Sb-125 1.30E-02 2.96E-02 Cs-134 4.13E-04 9.42E-04 1.66E-02 9.73E-03 Cs-137 2.05E+00 4.67E+00 1.81E+01 1.06E+01 Ce-144 4.96E-02 1.13E-01 7.83E-02 4.59E-02 Pu-238 2.65E-04 6.04E-04 2.08E-03 1.22E-03 Pu-239 6.84E-05 1.56E-04 6.31E-04 3.70E-04 Pu-240 1.96E-04 1.15E-04 Pu-241 1.92E-02 4.38E-02 1.80E-01 1.05E-01 Am-241 2.11E-04 4.81E-04 3.27E-03 1.92E-03 Cm-242 4.93E-05 1.12E-04 9.70E-05 5.69E-05 Cm-243 1.54E-04 3.51E-04 1.56E-03 9.14E-04 Cm-244 1.53E-04 3.49E-04 1.53E-03 8.97E-04 Totals 4.39E+01 1.00E+02 1.71E+02 1.00E+02 Note: Grey fields are where results were not reported in the NRC Regulatory Guide 1.21 Report 20

Oyster Creek 2013 Annual Radioactive Effluent Release Report Category B - Dry Compressible Waste, Contaminated Equipment, etc.

Isotope Waste Class A Curies Percent H-3 7.86E-05 1.21E-01 C-14 5.83E-05 9.00E-02 Mn-54 7.73E-03 1.19E+01 Fe-55 4.17E-02 6.44E+01 Co-60 1.31E-02 2.02E+01 Ni-63 8.27E-04 1.28E+00 Zn-65 5.07E-04 7.83E-01 Tc-99 3.31E-05 5.11E-02 Sb-125 1.97E-04 3.04E-01 Cs-137 3.68E-04 5.68E-01 Ce-144 1.43E-04 2.21E-01 Pu-238 8.58E-07 1.32E-03 Pu-239 2.25E-07 3.47E-04 Pu-241 2.01E-05 3.10E-02 Am-241 9.49E-07 1.47E-03 Cm-242 3.62E-07 5.59E-04 Cm-243 7.28E-07 1.12E-03 Cm-244 7.27E-07 1.12E-03 Totals 6.48E-02 1.00E+02 Category C - Irradiated components, control rods, etc.

No Irradiated components, control rods, etc. shipped 21

Oyster Creek 2013 Annual Radioactive Effluent Release Report Category D - Other - Scrap Metal Isotope Waste Class A Curies Percent H-3 5.25E-05 1.22E-01 C-14 3.89E-05 9.04E-02 Mn-54 5.09E-03 1.18E+01 Fe-55 2.77E-02 6.44E+01 Co-60 8.75E-03 2.03E+01 Ni-63 5.52E-04 1.28E+00 Zn-65 3.33E-04 7.74E-01 Tc-99 2.21E-05 5.14E-02 Sb-125 1.31E-04 3.04E-01 Cs-137 2.46E-04 5.72E-01 Ce-144 9.42E-05 2.19E-01 Pu-238 5.73E-07 1.33E-03 Pu-239 1.50E-07 3.49E-04 Pu-241 1.34E-05 3.11E-02 Am-241 6.34E-07 1.47E-03 Cm-242 2.36E-07 5.49E-04 Cm-243 4.86E-07 1.13E-03 Cm-244 4.85E-07 1.13E-03 Totals 4.30E-02 1.00E+02 Note: Grey fields are where results were not reported in the NRC Regulatory Guide 1.21 Report

2. Solid Waste (Disposition)

Number of Shipments Mode of Transportation Destination 10 Hittman Transport Co. Barnwell Disposal Facility 9 Hittman Transport Co. Duratek - Bear Creek 2 Hittman Transport Co. Duratek Radwaste Processing, Inc.

B. Irradiated Fuel Shipments (disposition).

There were no irradiated fuel shipments C. Changes to the Process Control Program There were no changes to the Process Control Program in 2013 22

Oyster Creek 2013 Annual Radioactive Effluent Release Report Appendix C Radiological Impact to Man 23

Oyster Creek 2013 Annual Radioactive Effluent Release Report Per ODCM Administrative Control 6.2, an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year must be made to show conformance with 40 CFR Part 190, Environmental Radiation Protection Standards for Nuclear Power Operation. For purposes of this calculation the following assumptions were made:

Gaseous Nearest member of the public was W sector at 483 meters Actual 2013 meteorology and measured gaseous effluent releases were used All significant pathways were assumed to be present Occupancy factor was considered 22.8% (40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br />s/week for 50 weeks).

Liquid Doses calculated in the discharge canal at the Route 9 bridge Fish, shellfish and shoreline pathways doses calculated 40 CFR Part 190 Compliance Dosimetry measurements (minus average of control stations) measured direct radiation for the nearest member of the public. The nearest member of the public for direct radiation is considered an individual that works in the warehouse west of the site. As a worker, the individual is assumed to work 2,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> per year at this location.

Nearest resident was at SE sector at 937 meters.

The highest calculated dose for gamma air dose and liquid total body were summed for total body dose.

The highest calculated dose for gamma air dose, child bone and liquid organ were summed for organ dose.

The limits for Kr-85, I-129, Pu-239 and other alpha-emitting transuranic radionuclides with half-lives greater than one year were not exceeded.

The ODCM does not require total body doses to the population and average doses to individuals in the population from gaseous effluents to a distance of 50 miles from the site to be calculated.

24

Oyster Creek 2013 Annual Radioactive Effluent Release Report A summary of gaseous and liquid radiation doses to most likely exposed MEMBER OF THE PUBLIC was as follows:

Location  % of Applicable Estimated Age Distance Direction Applicable Effluent Organ Dose Group (meters) (toward) Limit Limit Unit Gamma -

Noble Gas Air Dose 3.60E-03 All 500 ESE 3.60E-02 10 mrad Beta - Air Noble Gas Dose 8.44E-04 All 500 ESE 4.22E-03 20 mrad Total Body Noble Gas (Gamma) 1.42E-03 All 937 SE 2.84E-02 5 mrem Noble Gas Skin (Beta) 1.77E-03 All 972 ESE 1.18E-02 15 mrem

Iodine, Particulate, Bone 4.93E-01 Child 937 SE 3.29E+00 15 mrem Carbon-14 &

Tritium Liquid Total body 1.37E-06 All South Route 9 4.57E-05 3 mrem Liquid Organ 1.37E-06 All Bridge 1.37E-05 10 mrem Direct Radiation Total Body 5.39E+00 All 483 W 2.16E+01 25 mrem Direct Radiation Total Body <LLD All 937 SE <LLD 25 mrem 40 CFR Part 190 Compliance Warehouse Worker Total Dose Total Body 5.39E+00 All 483 W 2.16E+01 25 mrem Total Dose Bone 5.50E+00 All 483 W 2.20E+01 25 mrem Total Dose Thyroid 5.39E+00 All 483 W 7.19E+00 75 mrem Nearest Resident Total Dose Total Body 3.60E-03 All 937 SE 1.44E-02 25 mrem Total Dose Bone 4.97E-01 All 937 SE 1.99E+00 25 mrem Total Dose Thyroid 3.60E-03 All 937 SE 4.80E-03 75 mrem 25

Oyster Creek 2013 Annual Radioactive Effluent Release Report Appendix D Meteorological Data 26

Oyster Creek 2013 Annual Radioactive Effluent Release Report LIST OF METEOROLOGICAL DATA TABLES PAGE Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for 28 the Oyster Creek Generating Station, January - March, 2013 Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for 35 the Oyster Creek Generating Station, January - March, 2013 Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for 42 the Oyster Creek Generating Station, April - June, 2013 Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for 49 the Oyster Creek Generating Station, April - June, 2013 Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for 56 the Oyster Creek Generating Station, July - September, 2013 Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for 63 the Oyster Creek Generating Station, July - September, 2013 Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for 70 the Oyster Creek Generating Station, October - December, 2013 Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for 77 the Oyster Creek Generating Station, October - December, 2013 Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for 84 the Oyster Creek Generating Station, January - December, 2013 Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for 92 the Oyster Creek Generating Station, January - December, 2013 27

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 2 0 0 0 4 NNE 0 1 0 0 0 0 1 NE 0 3 0 0 0 0 3 ENE 0 1 4 0 0 0 5 E 0 2 2 0 0 0 4 ESE 0 2 2 0 0 0 4 SE 0 1 3 0 0 0 4 SSE 0 0 2 0 0 0 2 S 0 0 1 0 0 0 1 SSW 0 1 2 4 0 0 7 SW 0 3 6 1 0 0 10 WSW 0 0 8 2 0 0 10 W 0 6 8 7 0 0 21 WNW 0 1 44 23 0 0 68 NW 0 2 34 5 0 0 41 NNW 0 0 10 0 0 0 10 Variable 0 0 0 0 0 0 0 Total 0 25 128 42 0 0 195 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 28

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 1 0 0 0 0 1 ENE 0 3 4 0 0 0 7 E 0 5 1 0 0 0 6 ESE 0 1 0 0 0 0 1 SE 0 0 1 0 0 0 1 SSE 0 0 3 3 0 0 6 S 0 1 1 0 0 0 2 SSW 0 1 0 1 0 0 2 SW 0 1 2 0 0 0 3 WSW 0 1 2 0 0 0 3 W 0 1 7 3 0 0 11 WNW 0 3 16 7 0 0 26 NW 0 0 15 6 0 0 21 NNW 0 2 4 2 0 0 8 Variable 0 0 0 0 0 0 0 Total 0 20 56 22 0 0 98 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 29

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 1 0 0 0 0 1 ENE 0 3 3 0 0 0 6 E 0 1 0 0 0 0 1 ESE 0 1 0 0 0 0 1 SE 0 1 0 0 0 0 1 SSE 0 2 0 0 0 0 2 S 0 0 0 0 0 0 0 SSW 0 1 0 0 0 0 1 SW 0 0 1 0 0 0 1 WSW 0 0 4 0 0 0 4 W 0 2 5 2 0 0 9 WNW 0 5 8 2 0 0 15 NW 0 1 6 0 0 0 7 NNW 0 0 3 1 0 0 4 Variable 0 0 0 0 0 0 0 Total 0 18 30 5 0 0 53 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 30

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 11 1 0 0 0 15 NNE 1 9 0 0 0 0 10 NE 2 12 1 5 0 0 20 ENE 1 7 10 7 0 0 25 E 1 3 1 0 0 0 5 ESE 1 8 0 0 0 0 9 SE 1 5 1 0 0 0 7 SSE 0 7 2 0 0 0 9 S 2 5 6 0 1 0 14 SSW 1 7 10 4 5 0 27 SW 1 5 4 2 0 0 12 WSW 2 5 1 0 0 0 8 W 3 5 19 4 0 0 31 WNW 1 24 28 15 0 0 68 NW 2 25 23 8 0 0 58 NNW 1 18 9 0 0 0 28 Variable 0 0 0 0 0 0 0 Total 23 156 116 45 6 0 346 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 31

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 25 8 4 0 0 42 NNE 10 14 12 7 1 0 44 NE 5 22 19 7 0 0 53 ENE 5 13 8 9 0 0 35 E 5 9 2 2 0 0 18 ESE 3 6 2 0 0 0 11 SE 4 13 1 1 0 0 19 SSE 5 14 8 10 0 0 37 S 7 14 9 3 2 0 35 SSW 8 19 25 3 1 0 56 SW 5 24 9 2 0 0 40 WSW 11 44 6 0 0 0 61 W 12 74 21 2 0 0 109 WNW 21 135 63 12 0 0 231 NW 19 83 37 1 0 0 140 NNW 4 44 37 1 0 0 86 Variable 0 0 0 0 0 0 0 Total 129 553 267 64 4 0 1017 Hours of calm in this stability class: 3 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 32

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 2 0 0 0 0 3 NNE 1 0 0 0 0 0 1 NE 1 0 0 0 0 0 1 ENE 1 0 0 0 0 0 1 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 SSE 2 0 0 0 0 0 2 S 3 4 0 0 0 0 7 SSW 9 3 0 0 0 0 12 SW 9 15 0 0 0 0 24 WSW 15 24 0 0 0 0 39 W 13 39 0 1 0 0 53 WNW 5 43 1 0 0 0 49 NW 10 5 0 0 0 0 15 NNW 2 3 0 0 0 0 5 Variable 1 0 0 0 0 0 1 Total 73 138 1 1 0 0 213 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 33

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 1 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 0 0 0 0 1 NNE 1 1 0 0 0 0 2 NE 1 0 0 0 0 0 1 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 3 0 0 0 0 0 3 SSE 1 0 0 0 0 0 1 S 8 0 0 0 0 0 8 SSW 6 0 0 0 0 0 6 SW 16 5 0 0 0 0 21 WSW 41 10 0 0 0 0 51 W 50 16 0 0 0 0 66 WNW 28 8 0 0 0 0 36 NW 18 2 0 0 0 0 20 NNW 8 2 0 0 0 0 10 Variable 0 0 0 0 0 0 0 Total 181 45 0 0 0 0 226 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 34

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Extremely Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 S 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 0 0 0 0 W 0 0 0 0 3 0 3 WNW 0 0 0 0 1 0 1 NW 0 0 0 0 4 1 5 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 0 0 0 8 1 9 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 35

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Moderately Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 2 0 0 3 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 1 0 0 0 1 E 0 0 1 0 0 0 1 ESE 0 0 0 0 0 0 0 SE 0 0 0 0 0 0 0 SSE 0 0 0 0 0 0 0 S 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 0 0 2 0 0 2 W 0 0 0 0 2 0 2 WNW 0 0 2 5 3 5 15 NW 0 0 3 6 5 7 21 NNW 0 0 0 3 1 0 4 Variable 0 0 0 0 0 0 0 Total 0 0 8 18 11 12 49 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 36

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Slightly Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 1 3 0 0 6 NNE 0 1 0 0 0 0 1 NE 0 1 1 0 0 0 2 ENE 0 0 2 1 0 0 3 E 0 0 2 0 0 0 2 ESE 0 0 2 0 0 0 2 SE 0 0 0 0 0 0 0 SSE 0 0 0 1 0 0 1 S 0 0 0 2 0 0 2 SSW 0 0 0 0 1 1 2 SW 0 0 1 1 0 0 2 WSW 0 0 2 2 1 1 6 W 0 0 0 0 1 4 5 WNW 0 0 2 4 10 5 21 NW 0 0 2 18 8 8 36 NNW 0 0 0 6 3 1 10 Variable 0 0 0 0 0 0 0 Total 0 4 15 38 24 20 101 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 37

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Neutral - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 5 18 14 3 0 41 NNE 2 10 17 4 2 2 37 NE 0 6 10 7 5 7 35 ENE 0 3 12 12 4 16 47 E 1 6 5 7 5 5 29 ESE 0 3 7 0 0 0 10 SE 0 4 6 1 0 0 11 SSE 0 4 5 1 4 0 14 S 0 4 13 1 1 1 20 SSW 1 8 6 7 7 13 42 SW 0 3 8 12 10 1 34 WSW 1 3 2 14 7 1 28 W 1 2 10 12 16 5 46 WNW 0 2 18 36 28 24 108 NW 1 3 19 83 34 35 175 NNW 0 3 19 29 37 5 93 Variable 0 0 0 0 0 0 0 Total 8 69 175 240 163 115 770 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 38

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Slightly Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 0 10 19 12 2 45 NNE 2 5 6 9 2 8 32 NE 0 5 5 7 2 8 27 ENE 0 0 1 5 3 14 23 E 1 0 3 11 5 3 23 ESE 1 2 5 12 1 0 21 SE 0 1 5 5 2 1 14 SSE 1 3 2 8 4 2 20 S 3 1 5 6 7 15 37 SSW 2 1 5 14 20 6 48 SW 0 1 13 13 22 9 58 WSW 0 4 8 15 9 0 36 W 0 2 3 31 32 8 76 WNW 0 3 12 54 94 3 166 NW 1 4 11 71 76 11 174 NNW 0 1 16 26 23 1 67 Variable 0 0 0 0 0 0 0 Total 13 33 110 306 314 91 867 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 39

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Moderately Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 1 7 1 0 11 NNE 0 2 1 3 0 0 6 NE 1 3 1 1 0 0 6 ENE 0 1 0 1 1 0 3 E 0 0 0 0 0 0 0 ESE 0 0 3 0 0 0 3 SE 0 0 0 1 0 0 1 SSE 0 0 2 1 0 0 3 S 1 0 0 0 2 0 3 SSW 1 1 0 2 3 0 7 SW 0 0 3 10 8 5 26 WSW 0 1 5 4 2 0 12 W 0 1 8 13 8 0 30 WNW 0 1 3 18 16 3 41 NW 0 0 5 16 31 12 64 NNW 0 0 2 13 7 0 22 Variable 0 0 0 0 0 0 0 Total 3 12 34 90 79 20 238 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 40

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 2 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - March, 2013 Oyster Creek Alpha Period of Record: January - March 2013 Stability Class - Extremely Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 4 6 2 0 0 12 NNE 0 3 4 2 0 0 9 NE 0 0 3 1 0 0 4 ENE 0 1 3 3 0 0 7 E 0 0 4 1 0 0 5 ESE 0 0 3 0 0 0 3 SE 0 0 2 0 0 0 2 SSE 0 0 3 1 0 0 4 S 0 0 0 1 0 0 1 SSW 0 0 0 1 0 0 1 SW 0 3 2 3 6 1 15 WSW 1 0 5 5 0 0 11 W 0 4 6 4 2 0 16 WNW 1 1 3 0 1 0 6 NW 0 2 1 5 5 0 13 NNW 0 0 3 4 3 0 10 Variable 0 0 0 0 0 0 0 Total 2 18 48 33 17 1 119 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 41

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 3 0 0 0 6 NNE 0 0 3 0 0 0 3 NE 0 4 15 0 0 0 19 ENE 0 10 53 3 0 0 66 E 0 6 20 0 0 0 26 ESE 0 9 27 0 0 0 36 SE 0 18 37 0 0 0 55 SSE 0 5 36 2 0 0 43 S 1 9 65 36 0 0 111 SSW 1 8 12 7 0 0 28 SW 0 15 19 0 0 0 34 WSW 0 24 23 2 0 0 49 W 1 15 18 4 0 0 38 WNW 0 7 43 13 0 0 63 NW 0 12 14 1 0 0 27 NNW 1 7 7 0 0 0 15 Variable 0 0 0 0 0 0 0 Total 4 152 395 68 0 0 619 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 42

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 0 0 0 3 NNE 0 2 0 0 0 0 2 NE 0 2 2 0 0 0 4 ENE 0 3 7 3 0 0 13 E 0 2 2 2 0 0 6 ESE 0 2 1 0 0 0 3 SE 0 5 0 0 0 0 5 SSE 1 2 4 0 0 0 7 S 0 1 5 1 0 0 7 SSW 0 2 5 2 0 0 9 SW 0 1 1 0 0 0 2 WSW 1 8 3 0 0 0 12 W 0 4 1 0 0 0 5 WNW 1 4 7 0 0 0 12 NW 1 3 6 0 0 0 10 NNW 0 2 1 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 4 43 48 8 0 0 103 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 43

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 0 0 0 0 1 NNE 0 1 1 0 0 0 2 NE 0 2 2 0 0 0 4 ENE 0 0 2 2 0 0 4 E 0 4 0 0 0 0 4 ESE 0 2 0 0 0 0 2 SE 0 0 0 0 0 0 0 SSE 0 2 3 0 0 0 5 S 1 1 4 1 0 0 7 SSW 0 2 0 1 0 0 3 SW 0 2 0 0 0 0 2 WSW 0 5 0 0 0 0 5 W 1 1 1 0 0 0 3 WNW 0 2 0 0 0 0 2 NW 0 1 3 3 0 0 7 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 2 26 16 7 0 0 51 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 44

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 6 2 0 0 0 9 NNE 0 6 8 0 0 0 14 NE 1 16 11 0 0 0 28 ENE 1 7 8 8 0 0 24 E 0 15 5 1 0 0 21 ESE 2 14 14 0 0 0 30 SE 0 20 17 0 0 0 37 SSE 1 15 13 0 0 0 29 S 2 16 34 5 0 0 57 SSW 2 22 22 3 0 0 49 SW 1 5 3 0 0 0 9 WSW 2 14 9 0 0 0 25 W 1 7 2 0 0 0 10 WNW 0 5 20 0 0 0 25 NW 0 6 14 0 0 0 20 NNW 1 2 3 0 0 0 6 Variable 0 0 0 0 0 0 0 Total 15 176 185 17 0 0 393 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 45

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 4 3 0 0 0 11 NNE 2 8 0 0 0 0 10 NE 6 17 6 0 0 0 29 ENE 4 15 17 0 0 0 36 E 2 20 7 0 0 0 29 ESE 1 18 2 0 0 0 21 SE 3 12 5 0 0 0 20 SSE 2 14 8 2 0 0 26 S 8 29 20 0 0 0 57 SSW 13 57 29 2 0 0 101 SW 7 63 9 0 0 0 79 WSW 16 48 4 0 0 0 68 W 10 18 4 0 0 0 32 WNW 8 26 10 0 0 0 44 NW 3 15 5 0 0 0 23 NNW 4 24 3 0 0 0 31 Variable 0 0 0 0 0 0 0 Total 93 388 132 4 0 0 617 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 46

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 0 0 0 0 2 NNE 3 0 0 0 0 0 3 NE 2 1 0 0 0 0 3 ENE 2 1 0 0 0 0 3 E 1 0 0 0 0 0 1 ESE 2 0 0 0 0 0 2 SE 2 1 0 0 0 0 3 SSE 7 2 0 0 0 0 9 S 15 2 0 0 0 0 17 SSW 6 2 0 0 0 0 8 SW 6 7 0 0 0 0 13 WSW 13 15 0 0 0 0 28 W 11 14 0 0 0 0 25 WNW 6 8 0 0 0 0 14 NW 5 8 0 0 0 0 13 NNW 3 5 0 0 0 0 8 Variable 0 0 0 0 0 0 0 Total 85 67 0 0 0 0 152 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 47

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 3 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 0 0 0 0 0 4 NNE 0 1 0 0 0 0 1 NE 0 0 0 0 0 0 0 ENE 2 1 0 0 0 0 3 E 0 0 0 0 0 0 0 ESE 1 0 0 0 0 0 1 SE 0 0 0 0 0 0 0 SSE 2 0 0 0 0 0 2 S 7 0 0 0 0 0 7 SSW 9 2 0 0 0 0 11 SW 11 3 0 0 0 0 14 WSW 39 15 0 0 0 0 54 W 64 8 0 0 0 0 72 WNW 26 6 1 0 0 0 33 NW 19 5 0 0 0 0 24 NNW 7 6 0 0 0 0 13 Variable 0 0 0 0 0 0 0 Total 191 47 1 0 0 0 239 Hours of calm in this stability class: 3 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 48

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Extremely Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 1 0 0 1 ENE 0 0 0 3 1 0 4 E 0 0 2 0 0 0 2 ESE 0 0 0 0 0 0 0 SE 0 0 0 1 0 0 1 SSE 0 0 0 2 0 0 2 S 0 0 1 5 1 0 7 SSW 0 0 0 5 7 1 13 SW 0 0 2 5 0 0 7 WSW 0 0 1 2 1 0 4 W 0 0 5 1 0 0 6 WNW 0 0 1 0 15 1 17 NW 0 0 0 3 2 1 6 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 0 12 28 27 3 70 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 49

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Moderately Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 1 3 0 0 4 ENE 0 0 4 9 4 1 18 E 0 0 4 4 1 0 9 ESE 0 0 1 1 0 0 2 SE 0 0 4 1 0 0 5 SSE 0 1 5 5 1 0 12 S 0 0 2 9 1 0 12 SSW 0 0 6 9 9 3 27 SW 0 0 4 5 0 0 9 WSW 0 0 6 11 2 0 19 W 0 0 8 5 2 0 15 WNW 0 0 2 4 11 2 19 NW 0 0 4 6 0 0 10 NNW 0 0 1 2 0 0 3 Variable 0 0 0 0 0 0 0 Total 0 1 52 74 31 6 164 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 50

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Slightly Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 2 0 0 2 NNE 0 0 0 0 0 0 0 NE 0 1 3 5 0 1 10 ENE 0 0 1 6 3 0 10 E 0 0 2 5 2 0 9 ESE 0 1 1 2 0 0 4 SE 0 2 5 2 0 0 9 SSE 0 0 9 4 0 0 13 S 0 0 6 13 1 0 20 SSW 0 1 3 12 8 2 26 SW 0 1 4 2 0 0 7 WSW 0 1 8 2 2 0 13 W 0 2 7 8 1 0 18 WNW 0 0 1 11 6 1 19 NW 0 0 6 6 1 0 13 NNW 0 0 4 3 1 0 8 Variable 0 0 0 0 0 0 0 Total 0 9 60 83 25 4 181 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 5 51

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Neutral - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 5 10 1 0 16 NNE 0 2 10 6 0 0 18 NE 0 0 16 15 5 0 36 ENE 0 1 21 32 14 16 84 E 0 2 24 15 8 0 49 ESE 1 5 32 28 1 0 67 SE 0 6 31 24 11 0 72 SSE 0 3 21 13 7 0 44 S 0 5 18 37 5 1 66 SSW 0 7 14 48 33 11 113 SW 0 9 10 12 2 0 33 WSW 1 8 11 12 3 0 35 W 0 7 17 11 4 0 39 WNW 1 4 11 9 12 1 38 NW 0 2 10 11 25 16 64 NNW 0 3 5 13 2 0 23 Variable 0 0 0 0 0 0 0 Total 3 64 256 296 133 45 797 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 2 Hours of missing stability measurements in all stability classes: 5 52

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Slightly Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 4 8 3 0 15 NNE 0 4 8 5 0 0 17 NE 0 3 5 3 0 0 11 ENE 0 2 7 11 5 5 30 E 0 1 3 10 6 0 20 ESE 0 1 4 4 3 1 13 SE 0 1 9 6 0 0 16 SSE 0 5 10 16 5 2 38 S 0 3 10 17 6 0 36 SSW 0 1 14 37 38 2 92 SW 0 2 12 42 52 4 112 WSW 1 5 10 16 24 4 60 W 1 3 8 20 14 0 46 WNW 0 4 4 14 16 0 38 NW 0 1 2 10 18 1 32 NNW 0 1 7 9 17 0 34 Variable 0 0 0 0 0 0 0 Total 2 37 117 228 207 19 610 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 53

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Moderately Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 0 1 2 0 4 NNE 0 0 2 3 0 0 5 NE 0 0 4 1 0 0 5 ENE 0 0 0 5 1 0 6 E 0 0 1 0 0 0 1 ESE 0 0 0 0 0 0 0 SE 0 0 2 0 0 0 2 SSE 0 1 1 2 0 0 4 S 0 5 3 13 0 0 21 SSW 0 1 4 6 0 0 11 SW 0 0 3 7 6 0 16 WSW 0 2 6 5 14 5 32 W 0 0 1 9 5 3 18 WNW 1 1 2 8 13 4 29 NW 0 0 3 11 8 0 22 NNW 0 0 1 6 12 1 20 Variable 0 0 0 0 0 0 0 Total 1 11 33 77 61 13 196 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 54

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 4 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, April - June, 2013 Oyster Creek Alpha Period of Record: April - June 2013 Stability Class - Extremely Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 4 3 0 7 NNE 0 0 0 3 2 0 5 NE 0 0 5 2 0 0 7 ENE 0 0 1 3 0 0 4 E 0 0 1 1 0 0 2 ESE 0 1 1 0 0 0 2 SE 0 0 1 0 0 0 1 SSE 0 0 5 1 0 0 6 S 0 2 4 2 0 0 8 SSW 0 5 4 11 0 0 20 SW 1 2 4 4 1 0 12 WSW 0 2 4 12 7 0 25 W 0 2 3 14 4 0 23 WNW 0 0 1 3 4 0 8 NW 1 0 3 8 4 1 17 NNW 0 0 2 1 5 2 10 Variable 0 0 0 0 0 0 0 Total 2 14 39 69 30 3 157 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 55

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 7 0 0 0 0 8 NNE 1 8 4 0 0 0 13 NE 1 8 21 0 0 0 30 ENE 1 14 20 0 0 0 35 E 1 12 3 0 0 0 16 ESE 2 18 11 0 0 0 31 SE 0 12 38 0 0 0 50 SSE 0 7 33 1 0 0 41 S 0 5 57 8 0 0 70 SSW 1 18 17 0 0 0 36 SW 0 31 32 0 0 0 63 WSW 2 31 28 0 0 0 61 W 0 35 8 0 0 0 43 WNW 0 34 15 0 0 0 49 NW 0 36 29 0 0 0 65 NNW 0 23 4 0 0 0 27 Variable 0 0 0 0 0 0 0 Total 10 299 320 9 0 0 638 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 5 Hours of missing stability measurements in all stability classes: 24 56

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 0 0 0 0 1 NNE 0 2 0 0 0 0 2 NE 0 3 2 0 0 0 5 ENE 1 3 0 0 0 0 4 E 1 1 0 0 0 0 2 ESE 0 1 0 0 0 0 1 SE 0 1 3 0 0 0 4 SSE 0 4 5 0 0 0 9 S 0 1 1 0 0 0 2 SSW 2 1 3 0 0 0 6 SW 0 3 2 0 0 0 5 WSW 1 5 0 0 0 0 6 W 0 8 0 0 0 0 8 WNW 2 5 0 0 0 0 7 NW 1 7 4 0 0 0 12 NNW 0 6 1 0 0 0 7 Variable 0 0 0 0 0 0 0 Total 8 52 21 0 0 0 81 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 57

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 1 0 0 0 0 1 NE 0 1 2 0 0 0 3 ENE 0 1 0 0 0 0 1 E 0 1 0 0 0 0 1 ESE 0 3 0 0 0 0 3 SE 0 2 0 0 0 0 2 SSE 0 2 1 0 0 0 3 S 0 3 3 1 0 0 7 SSW 0 2 4 0 0 0 6 SW 0 3 0 0 0 0 3 WSW 1 4 1 0 0 0 6 W 1 3 1 0 0 0 5 WNW 2 3 1 0 0 0 6 NW 0 0 3 0 0 0 3 NNW 0 2 0 0 0 0 2 Variable 0 0 0 0 0 0 0 Total 4 31 16 1 0 0 52 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 58

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 11 0 0 0 0 13 NNE 2 10 4 0 0 0 16 NE 1 6 12 0 0 0 19 ENE 0 8 4 0 0 0 12 E 2 4 0 0 0 0 6 ESE 0 2 0 0 0 0 2 SE 0 7 1 0 0 0 8 SSE 1 10 3 0 0 0 14 S 0 38 38 0 0 0 76 SSW 2 17 14 0 0 0 33 SW 3 20 0 0 0 0 23 WSW 3 16 2 0 0 0 21 W 3 9 0 0 0 0 12 WNW 2 7 0 0 0 0 9 NW 4 13 3 0 0 0 20 NNW 1 11 0 0 0 0 12 Variable 0 0 0 0 0 0 0 Total 26 189 81 0 0 0 296 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 59

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 7 10 1 0 0 0 18 NNE 6 3 1 0 0 0 10 NE 5 14 3 0 0 0 22 ENE 7 6 0 0 0 0 13 E 2 6 0 0 0 0 8 ESE 3 4 0 0 0 0 7 SE 6 4 0 0 0 0 10 SSE 7 10 1 0 0 0 18 S 18 35 13 0 0 0 66 SSW 13 83 7 0 0 0 103 SW 13 93 2 0 0 0 108 WSW 20 73 0 0 0 0 93 W 13 8 0 0 0 0 21 WNW 10 13 0 0 0 0 23 NW 9 22 2 0 0 0 33 NNW 2 13 0 0 0 0 15 Variable 0 0 0 0 0 0 0 Total 141 397 30 0 0 0 568 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 2 Hours of missing stability measurements in all stability classes: 24 60

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 1 0 0 0 0 4 NNE 5 2 0 0 0 0 7 NE 2 1 0 0 0 0 3 ENE 0 0 0 0 0 0 0 E 1 0 0 0 0 0 1 ESE 0 0 0 0 0 0 0 SE 2 0 0 0 0 0 2 SSE 4 0 0 0 0 0 4 S 11 3 1 0 0 0 15 SSW 8 3 0 0 0 0 11 SW 14 12 0 0 0 0 26 WSW 13 18 0 0 0 0 31 W 13 2 0 0 0 0 15 WNW 7 7 0 0 0 0 14 NW 6 16 0 0 0 0 22 NNW 9 6 0 0 0 0 15 Variable 0 0 0 0 0 0 0 Total 98 71 1 0 0 0 170 Hours of calm in this stability class: 3 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 61

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 5 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 1 0 0 0 0 7 NNE 3 1 0 0 0 0 4 NE 0 0 0 0 0 0 0 ENE 0 2 0 0 0 0 2 E 1 0 0 0 0 0 1 ESE 0 0 0 0 0 0 0 SE 1 0 0 0 0 0 1 SSE 2 0 0 0 0 0 2 S 4 0 0 0 0 0 4 SSW 7 0 0 0 0 0 7 SW 11 0 0 0 0 0 11 WSW 61 8 0 0 0 0 69 W 103 5 0 0 0 0 108 WNW 62 9 0 0 0 0 71 NW 49 13 0 0 0 0 62 NNW 12 7 0 0 0 0 19 Variable 0 0 0 0 0 0 0 Total 322 46 0 0 0 0 368 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 24 62

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Extremely Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 1 1 0 0 2 NE 0 0 1 8 0 0 9 ENE 0 0 0 6 0 0 6 E 0 0 4 0 0 0 4 ESE 0 0 3 0 0 0 3 SE 0 0 6 1 0 0 7 SSE 0 0 0 2 0 0 2 S 0 0 0 6 0 0 6 SSW 0 0 0 4 0 0 4 SW 0 0 6 4 1 0 11 WSW 0 0 3 22 1 0 26 W 0 0 6 1 0 0 7 WNW 0 2 7 2 0 0 11 NW 0 0 6 7 0 0 13 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 2 43 64 2 0 111 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 63

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Moderately Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 0 0 0 3 NNE 0 0 3 1 0 0 4 NE 0 0 2 6 0 0 8 ENE 0 0 4 7 0 0 11 E 0 2 2 1 0 0 5 ESE 0 3 5 0 0 0 8 SE 0 1 17 1 0 0 19 SSE 0 1 6 7 0 0 14 S 0 0 2 9 4 0 15 SSW 0 1 7 8 2 0 18 SW 0 1 8 6 0 0 15 WSW 0 4 6 9 1 0 20 W 0 2 8 3 0 0 13 WNW 0 3 13 4 0 0 20 NW 0 3 11 13 3 0 30 NNW 0 1 6 2 0 0 9 Variable 0 0 0 0 0 0 0 Total 0 22 103 77 10 0 212 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 64

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Slightly Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 2 0 0 0 4 NNE 0 1 4 0 0 0 5 NE 0 2 1 5 0 0 8 ENE 0 2 3 2 0 0 7 E 0 0 4 1 0 0 5 ESE 0 1 3 0 0 0 4 SE 0 2 9 1 0 0 12 SSE 0 0 8 3 1 0 12 S 0 0 5 5 0 0 10 SSW 0 0 3 14 5 0 22 SW 0 1 3 4 0 0 8 WSW 0 2 6 13 0 0 21 W 0 2 4 4 1 0 11 WNW 0 4 5 3 0 0 12 NW 0 2 11 8 2 0 23 NNW 0 3 3 4 0 0 10 Variable 0 0 0 0 0 0 0 Total 1 23 74 67 9 0 174 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 65

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Neutral - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 2 10 4 0 0 17 NNE 0 3 7 11 0 0 21 NE 0 4 9 20 7 0 40 ENE 0 7 8 13 3 3 34 E 0 8 6 1 0 0 15 ESE 0 8 1 0 0 0 9 SE 1 7 7 2 1 0 18 SSE 0 3 14 13 1 0 31 S 1 2 34 17 10 0 64 SSW 0 4 15 68 13 0 100 SW 1 6 10 24 0 0 41 WSW 0 5 13 19 2 0 39 W 1 8 20 10 0 0 39 WNW 0 5 11 8 0 0 24 NW 0 8 14 17 3 0 42 NNW 0 2 18 10 1 0 31 Variable 0 0 0 0 0 0 0 Total 5 82 197 237 41 3 565 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 5 Hours of missing stability measurements in all stability classes: 24 66

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Slightly Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 4 13 1 0 21 NNE 0 0 6 3 1 0 10 NE 0 1 8 12 2 0 23 ENE 1 6 9 6 0 0 22 E 0 5 9 0 0 0 14 ESE 0 1 0 1 0 0 2 SE 0 5 4 0 0 0 9 SSE 2 8 12 4 0 1 27 S 0 3 14 20 3 0 40 SSW 1 3 20 64 7 0 95 SW 0 2 19 87 28 0 136 WSW 0 7 5 28 34 0 74 W 0 0 4 25 10 0 39 WNW 0 2 10 5 1 0 18 NW 1 5 9 16 4 0 35 NNW 0 3 4 5 12 0 24 Variable 0 0 0 0 0 0 0 Total 5 54 137 289 103 1 589 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 24 67

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Moderately Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 5 8 1 17 NNE 0 1 5 5 0 0 11 NE 1 0 4 5 0 0 10 ENE 0 0 1 5 0 0 6 E 1 1 1 0 0 0 3 ESE 0 3 0 0 0 0 3 SE 1 5 0 0 0 0 6 SSE 0 2 5 0 0 0 7 S 0 2 2 7 0 0 11 SSW 0 3 4 5 2 0 14 SW 1 2 1 17 16 1 38 WSW 0 3 3 11 24 0 41 W 0 1 1 5 19 0 26 WNW 2 0 1 5 6 0 14 NW 0 1 1 7 11 0 20 NNW 0 0 1 11 20 2 34 Variable 0 0 0 0 0 0 0 Total 6 24 33 88 106 4 261 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 2 Hours of missing stability measurements in all stability classes: 24 68

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 6 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, July - September, 2013 Oyster Creek Alpha Period of Record: July - September 2013 Stability Class - Extremely Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 2 6 4 0 13 NNE 0 0 6 12 0 0 18 NE 2 0 10 4 0 0 16 ENE 0 1 8 5 0 0 14 E 1 6 7 2 0 0 16 ESE 0 4 0 0 0 0 4 SE 1 3 0 0 0 0 4 SSE 0 2 0 0 0 0 2 S 0 2 1 1 0 0 4 SSW 1 6 11 5 0 0 23 SW 1 5 3 8 3 1 21 WSW 0 2 6 6 4 2 20 W 1 3 7 13 4 0 28 WNW 0 2 4 3 2 0 11 NW 1 2 4 7 9 0 23 NNW 0 6 10 9 17 4 46 Variable 0 0 0 0 0 0 0 Total 8 45 79 81 43 7 263 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 24 69

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 0 0 0 0 3 NNE 1 1 3 0 0 0 5 NE 0 18 12 2 0 0 32 ENE 0 6 4 0 0 0 10 E 0 5 0 0 0 0 5 ESE 0 5 1 0 0 0 6 SE 0 7 0 0 0 0 7 SSE 0 3 4 0 0 0 7 S 0 0 6 3 0 0 9 SSW 0 0 3 0 0 0 3 SW 0 3 5 2 0 0 10 WSW 0 14 6 0 0 0 20 W 0 4 17 3 0 0 24 WNW 0 12 34 1 0 0 47 NW 0 3 12 9 0 0 24 NNW 0 3 5 1 0 0 9 Variable 0 0 0 0 0 0 0 Total 1 87 112 21 0 0 221 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 70

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 3 0 0 0 0 3 NNE 0 2 1 0 0 0 3 NE 0 4 4 0 0 0 8 ENE 0 2 0 0 0 0 2 E 0 5 1 0 0 0 6 ESE 0 1 1 0 0 0 2 SE 0 3 1 0 0 0 4 SSE 0 3 1 0 0 0 4 S 0 2 3 1 0 0 6 SSW 0 0 1 2 0 0 3 SW 0 5 2 0 0 0 7 WSW 0 7 7 0 0 0 14 W 0 3 4 1 0 0 8 WNW 0 4 9 2 0 0 15 NW 0 1 1 3 0 0 5 NNW 0 6 5 0 0 0 11 Variable 0 0 0 0 0 0 0 Total 0 51 41 9 0 0 101 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 71

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 2 1 0 0 0 3 NE 0 0 3 0 0 0 3 ENE 0 2 1 0 0 0 3 E 0 2 0 0 0 0 2 ESE 0 2 0 0 0 0 2 SE 0 2 0 0 0 0 2 SSE 0 0 0 0 0 0 0 S 0 0 1 0 0 0 1 SSW 0 0 2 0 0 0 2 SW 0 4 1 0 0 0 5 WSW 1 1 4 0 0 0 6 W 0 2 6 0 0 0 8 WNW 0 1 4 2 0 0 7 NW 1 1 4 0 0 0 6 NNW 0 1 2 0 0 0 3 Variable 0 0 0 0 0 0 0 Total 2 20 29 2 0 0 53 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 72

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 14 1 0 0 0 21 NNE 3 8 2 0 0 0 13 NE 1 7 26 0 0 0 34 ENE 4 9 0 0 0 0 13 E 2 6 1 0 0 0 9 ESE 2 11 0 0 0 0 13 SE 3 11 0 0 0 0 14 SSE 5 4 4 0 0 0 13 S 3 9 9 3 1 0 25 SSW 5 5 14 3 0 0 27 SW 4 17 12 1 0 0 34 WSW 2 16 8 0 0 0 26 W 1 19 11 0 0 0 31 WNW 2 18 22 5 0 0 47 NW 1 10 14 1 0 0 26 NNW 4 24 13 1 0 0 42 Variable 0 0 0 0 0 0 0 Total 48 188 137 14 1 0 388 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 73

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 6 0 0 0 0 9 NNE 6 5 7 0 0 0 18 NE 8 10 60 2 0 0 80 ENE 3 6 10 0 0 0 19 E 4 6 10 0 0 0 20 ESE 1 3 3 1 0 0 8 SE 8 3 0 1 0 0 12 SSE 8 6 3 2 0 0 19 S 13 19 12 1 0 0 45 SSW 7 37 34 12 0 0 90 SW 4 72 9 1 0 0 86 WSW 9 55 2 1 0 0 67 W 7 52 5 1 0 0 65 WNW 10 44 28 3 0 0 85 NW 7 34 15 2 0 0 58 NNW 6 31 9 0 0 0 46 Variable 1 0 0 0 0 0 1 Total 105 389 207 27 0 0 728 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 74

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 10 2 0 0 0 0 12 NNE 4 0 0 0 0 0 4 NE 2 1 2 0 0 0 5 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 1 0 0 0 0 0 1 SE 5 1 0 0 0 0 6 SSE 3 1 0 0 0 0 4 S 5 2 0 0 0 0 7 SSW 2 3 0 0 0 0 5 SW 12 10 0 0 0 0 22 WSW 14 31 0 0 0 0 45 W 17 31 0 0 0 0 48 WNW 17 13 1 0 0 0 31 NW 17 18 0 0 0 0 35 NNW 7 12 0 0 0 0 19 Variable 0 0 0 0 0 0 0 Total 116 125 3 0 0 0 244 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 75

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 7 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 2 0 0 0 0 8 NNE 3 0 0 0 0 0 3 NE 0 1 0 0 0 0 1 ENE 1 0 0 0 0 0 1 E 1 0 0 0 0 0 1 ESE 1 0 0 0 0 0 1 SE 0 0 0 0 0 0 0 SSE 1 0 0 0 0 0 1 S 2 1 0 0 0 0 3 SSW 6 0 0 0 0 0 6 SW 21 8 0 0 0 0 29 WSW 98 28 0 0 0 0 126 W 88 34 0 0 0 0 122 WNW 53 6 0 0 0 0 59 NW 56 7 0 0 0 0 63 NNW 26 10 0 0 0 0 36 Variable 1 0 0 0 0 0 1 Total 364 97 0 0 0 0 461 Hours of calm in this stability class: 5 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 5 76

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Extremely Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 0 0 0 0 0 ENE 0 0 0 0 0 0 0 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 1 0 0 0 1 SSE 0 0 0 0 0 0 0 S 0 0 0 0 0 0 0 SSW 0 0 0 0 0 0 0 SW 0 0 0 0 0 0 0 WSW 0 2 1 1 0 0 4 W 0 0 0 2 0 0 2 WNW 0 0 1 3 0 0 4 NW 0 0 0 1 0 0 1 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 2 3 7 0 0 12 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 77

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Moderately Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 0 0 0 0 0 NE 0 0 7 3 1 2 13 ENE 0 0 0 3 0 0 3 E 0 0 0 0 0 0 0 ESE 0 0 0 0 0 0 0 SE 0 0 1 0 0 0 1 SSE 0 1 0 0 0 0 1 S 0 0 1 2 0 0 3 SSW 0 0 0 0 0 0 0 SW 0 0 1 0 1 1 3 WSW 0 0 3 0 0 0 3 W 0 0 1 1 0 0 2 WNW 0 0 2 9 0 0 11 NW 0 0 2 3 4 3 12 NNW 0 0 0 0 0 0 0 Variable 0 0 0 0 0 0 0 Total 0 1 18 21 6 6 52 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 78

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Slightly Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 0 0 0 0 0 NNE 0 0 1 2 0 0 3 NE 0 0 10 2 1 3 16 ENE 0 0 0 2 0 0 2 E 0 0 0 0 0 0 0 ESE 0 1 0 1 0 0 2 SE 0 1 1 0 0 0 2 SSE 0 0 5 1 0 0 6 S 0 0 1 1 0 1 3 SSW 0 0 1 0 0 1 2 SW 0 1 0 2 1 0 4 WSW 0 1 6 2 0 0 9 W 0 1 4 1 7 2 15 WNW 0 1 3 11 10 1 26 NW 0 0 4 8 4 7 23 NNW 0 0 1 4 1 1 7 Variable 0 0 0 0 0 0 0 Total 0 6 37 37 24 16 120 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 79

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Neutral - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 5 14 14 0 0 33 NNE 1 2 11 6 0 0 20 NE 0 10 11 2 16 36 75 ENE 1 6 8 5 0 0 20 E 1 5 6 3 0 0 15 ESE 1 11 9 4 0 0 25 SE 0 8 6 0 0 0 14 SSE 0 6 4 1 0 0 11 S 0 6 10 6 3 4 29 SSW 1 6 6 15 17 12 57 SW 0 8 8 19 22 4 61 WSW 0 8 14 21 11 1 55 W 1 2 12 31 12 3 61 WNW 1 0 13 35 27 19 95 NW 0 4 5 26 24 15 74 NNW 1 4 10 22 21 3 61 Variable 0 0 0 0 0 0 0 Total 8 91 147 210 153 97 706 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 80

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Slightly Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 1 4 5 4 0 15 NNE 0 0 8 1 0 0 9 NE 1 4 10 9 11 41 76 ENE 0 3 9 6 9 6 33 E 0 0 5 3 9 7 24 ESE 0 5 5 3 1 4 18 SE 0 5 7 2 1 2 17 SSE 0 3 4 2 1 3 13 S 0 1 9 16 5 2 33 SSW 0 3 5 18 18 16 60 SW 0 2 5 38 54 3 102 WSW 0 0 3 14 21 3 41 W 0 2 5 25 26 0 58 WNW 0 0 4 24 43 1 72 NW 0 0 6 16 26 2 50 NNW 0 3 2 12 14 0 31 Variable 0 0 0 0 0 0 0 Total 2 32 91 194 243 90 652 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 81

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Moderately Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 1 17 8 0 27 NNE 0 4 5 5 2 0 16 NE 0 1 9 5 0 0 15 ENE 0 1 2 7 0 0 10 E 0 0 8 2 0 0 10 ESE 0 0 7 1 0 0 8 SE 0 2 4 2 0 0 8 SSE 1 1 3 1 1 0 7 S 0 1 8 4 0 0 13 SSW 0 1 8 3 0 0 12 SW 1 2 2 8 6 2 21 WSW 0 1 1 4 8 4 18 W 0 2 5 10 18 6 41 WNW 1 2 5 16 32 11 67 NW 1 1 6 10 25 1 44 NNW 0 3 4 13 11 4 35 Variable 0 0 0 0 0 0 0 Total 4 23 78 108 111 28 352 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 82

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 8 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, October - December, 2013 Oyster Creek Alpha Period of Record: October - December 2013 Stability Class - Extremely Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 2 3 4 0 0 10 NNE 0 0 2 6 0 0 8 NE 0 1 11 10 3 0 25 ENE 0 2 6 3 0 0 11 E 0 1 15 7 0 0 23 ESE 0 1 5 0 0 0 6 SE 1 1 9 0 0 0 11 SSE 1 2 8 0 0 0 11 S 0 4 1 0 0 0 5 SSW 1 0 1 3 2 1 8 SW 0 1 1 7 5 2 16 WSW 0 1 3 18 11 6 39 W 2 0 7 16 14 2 41 WNW 0 3 2 22 24 4 55 NW 2 5 3 10 9 0 29 NNW 0 6 2 3 0 0 11 Variable 1 0 0 0 0 0 1 Total 9 30 79 109 68 15 310 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 83

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - All Stabilities - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 1 21 35 39 76 24 4 5 3 0 0 208 NNE 0 17 30 26 56 30 23 6 5 2 0 195 NE 1 9 24 30 97 108 85 50 7 1 0 412 ENE 1 10 17 36 62 106 57 42 12 0 0 343 E 0 6 15 25 67 59 19 7 1 0 0 199 ESE 1 3 14 23 74 65 16 2 0 0 0 198 SE 0 13 24 29 72 101 36 1 1 0 0 277 SSE 1 17 32 29 57 80 61 33 9 0 0 319 S 2 40 61 41 116 148 133 84 36 2 3 666 SSW 0 24 76 68 188 145 86 31 33 6 1 658 SW 1 40 84 145 234 132 43 15 2 0 0 696 WSW 4 95 238 260 237 124 36 13 1 0 0 1008 W 2 145 244 170 227 114 52 26 23 0 0 1003 WNW 5 99 141 136 255 227 142 109 42 0 0 1156 NW 3 77 128 139 180 168 110 38 17 0 0 860 NNW 2 37 56 95 146 96 43 13 2 0 0 490 Tot 24 653 1219 1291 2144 1727 946 475 194 11 4 8688 Hours of Calm . . . . . . . 18 Hours of Variable Direction 3 Hours of Valid Data . . . . 8709 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 84

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Extremely Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 1 0 14 6 0 0 0 0 0 21 NNE 0 0 1 2 8 4 7 0 0 0 0 22 NE 0 0 1 1 16 49 6 11 0 0 0 84 ENE 0 0 0 3 16 49 36 12 0 0 0 116 E 0 0 0 1 14 26 8 2 0 0 0 51 ESE 0 0 2 2 23 41 9 0 0 0 0 77 SE 0 0 0 1 21 68 26 0 0 0 0 116 SSE 0 0 0 1 8 31 38 13 2 0 0 93 S 0 0 1 0 8 36 57 64 25 0 0 191 SSW 0 0 0 2 21 24 13 4 10 0 0 74 SW 0 0 0 7 27 53 24 6 0 0 0 117 WSW 0 0 1 5 45 53 27 8 1 0 0 140 W 0 0 1 6 36 39 20 13 11 0 0 126 WNW 0 0 0 6 29 69 52 54 17 0 0 227 NW 0 0 0 5 31 58 44 9 10 0 0 157 NNW 0 0 1 6 22 23 6 3 0 0 0 61 Tot 0 0 9 48 339 629 373 199 76 0 0 1673 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 1673 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 85

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Moderately Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 0 0 3 4 0 0 0 0 0 7 NNE 0 0 0 2 4 0 1 0 0 0 0 7 NE 0 0 0 3 5 6 2 2 0 0 0 18 ENE 0 0 0 2 6 10 2 6 0 0 0 26 E 0 0 1 2 8 6 1 2 0 0 0 20 ESE 0 0 0 0 3 4 0 0 0 0 0 7 SE 0 0 0 0 7 7 0 0 0 0 0 14 SSE 0 0 1 0 7 8 4 6 0 0 0 26 S 0 0 0 0 4 7 2 2 2 0 0 17 SSW 0 0 2 1 2 2 7 1 5 0 0 20 SW 0 0 0 2 8 4 1 2 0 0 0 17 WSW 0 0 1 6 10 11 5 2 0 0 0 35 W 0 0 0 2 14 4 5 4 3 0 0 32 WNW 0 1 2 2 6 13 21 10 5 0 0 60 NW 0 1 1 0 9 15 9 10 3 0 0 48 NNW 0 0 0 4 8 9 5 2 1 0 0 29 Tot 0 2 8 26 104 110 65 49 19 0 0 383 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 383 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 86

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Slightly Unstable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 0 0 1 0 0 0 0 0 0 1 NNE 0 0 0 2 2 1 0 1 0 0 0 6 NE 0 0 0 0 2 6 1 2 0 0 0 11 ENE 0 0 0 2 3 6 1 1 1 0 0 14 E 0 0 0 1 6 1 0 0 0 0 0 8 ESE 0 0 0 2 6 0 0 0 0 0 0 8 SE 0 0 0 0 4 1 0 0 0 0 0 5 SSE 0 0 0 0 3 6 1 0 0 0 0 10 S 0 0 1 0 3 3 5 1 2 0 0 15 SSW 0 0 0 0 4 5 2 0 1 0 0 12 SW 0 0 0 3 4 2 2 0 0 0 0 11 WSW 0 1 1 3 6 8 1 1 0 0 0 21 W 0 0 2 0 6 10 4 1 2 0 0 25 WNW 0 0 2 2 8 9 5 2 2 0 0 30 NW 0 0 0 1 3 10 6 2 1 0 0 23 NNW 0 0 0 1 2 2 3 1 0 0 0 9 Tot 0 1 6 17 63 70 31 12 9 0 0 209 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 209 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 87

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Neutral - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 1 10 10 30 6 1 0 0 0 0 58 NNE 0 0 5 5 22 17 4 0 0 0 0 53 NE 0 1 4 6 28 20 26 11 5 0 0 101 ENE 0 1 5 15 12 13 9 15 4 0 0 74 E 0 1 3 6 18 10 1 2 0 0 0 41 ESE 0 0 4 10 24 11 5 0 0 0 0 54 SE 0 0 4 9 27 17 9 0 0 0 0 66 SSE 0 0 7 9 18 18 9 4 0 0 0 65 S 0 0 6 6 39 55 48 11 4 2 1 172 SSW 0 0 9 7 34 40 25 7 9 4 1 136 SW 0 0 7 12 26 20 9 4 0 0 0 78 WSW 0 2 7 13 34 21 3 0 0 0 0 80 W 0 1 5 6 30 18 18 3 3 0 0 84 WNW 0 1 4 6 35 43 26 24 10 0 0 149 NW 0 0 4 14 34 33 23 13 3 0 0 124 NNW 0 1 6 15 31 22 10 2 1 0 0 88 Tot 0 9 90 149 442 364 226 96 39 6 2 1423 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 1423 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 88

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Slightly Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 6 10 21 24 8 3 5 3 0 0 80 NNE 0 9 13 11 18 8 11 5 5 2 0 82 NE 0 5 15 19 45 25 49 23 2 1 0 184 ENE 0 7 9 13 23 27 9 8 7 0 0 103 E 0 3 9 15 21 16 9 1 1 0 0 75 ESE 0 2 5 9 18 9 2 2 0 0 0 47 SE 0 7 13 17 13 8 1 1 1 0 0 61 SSE 0 7 14 15 21 17 9 10 7 0 0 100 S 1 11 30 27 57 45 21 6 3 0 2 203 SSW 0 6 33 47 122 74 39 19 8 2 0 350 SW 0 6 21 69 152 53 7 3 2 0 0 313 WSW 1 9 40 91 115 31 0 2 0 0 0 289 W 0 11 28 38 94 43 5 5 3 0 0 227 WNW 1 10 31 46 141 89 38 19 8 0 0 383 NW 0 9 25 53 83 52 28 4 0 0 0 254 NNW 0 5 11 28 72 38 19 5 0 0 0 178 Tot 3 113 307 519 1019 543 250 118 50 5 2 2929 Hours of Calm . . . . . . . 4 Hours of Variable Direction 1 Hours of Valid Data . . . . 2934 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 89

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Moderately Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 1 5 9 2 4 0 0 0 0 0 0 21 NNE 0 3 10 0 2 0 0 0 0 0 0 15 NE 1 2 4 0 1 2 1 1 0 0 0 12 ENE 0 1 2 0 0 1 0 0 0 0 0 4 E 0 1 1 0 0 0 0 0 0 0 0 2 ESE 0 0 3 0 0 0 0 0 0 0 0 3 SE 0 5 4 2 0 0 0 0 0 0 0 11 SSE 0 5 10 4 0 0 0 0 0 0 0 19 S 0 15 18 6 5 2 0 0 0 0 0 46 SSW 0 5 18 8 5 0 0 0 0 0 0 36 SW 0 6 32 34 13 0 0 0 0 0 0 85 WSW 0 12 38 69 24 0 0 0 0 0 0 143 W 0 18 30 57 35 0 0 0 1 0 0 141 WNW 0 7 23 41 34 3 0 0 0 0 0 108 NW 0 7 27 33 18 0 0 0 0 0 0 85 NNW 0 6 14 19 6 2 0 0 0 0 0 47 Tot 2 98 243 275 147 10 1 1 1 0 0 778 Hours of Calm . . . . . . . 4 Hours of Variable Direction 1 Hours of Valid Data . . . . 783 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 90

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 9 Wind Speed by Direction Measured at 33 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Extremely Stable - 150Ft-33Ft Delta-T (F)

Winds Measured at 33 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 9 5 6 0 0 0 0 0 0 0 20 NNE 0 5 1 4 0 0 0 0 0 0 0 10 NE 0 1 0 1 0 0 0 0 0 0 0 2 ENE 1 1 1 1 2 0 0 0 0 0 0 6 E 0 1 1 0 0 0 0 0 0 0 0 2 ESE 1 1 0 0 0 0 0 0 0 0 0 2 SE 0 1 3 0 0 0 0 0 0 0 0 4 SSE 1 5 0 0 0 0 0 0 0 0 0 6 S 1 14 5 2 0 0 0 0 0 0 0 22 SSW 0 13 14 3 0 0 0 0 0 0 0 30 SW 1 28 24 18 4 0 0 0 0 0 0 75 WSW 3 71 150 73 3 0 0 0 0 0 0 300 W 2 115 178 61 12 0 0 0 0 0 0 368 WNW 4 80 79 33 2 1 0 0 0 0 0 199 NW 3 60 71 33 2 0 0 0 0 0 0 169 NNW 2 25 24 22 5 0 0 0 0 0 0 78 Tot 19 430 556 257 30 1 0 0 0 0 0 1293 Hours of Calm . . . . . . . 10 Hours of Variable Direction 1 Hours of Valid Data . . . . 1304 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 91

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - All Stabilities - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 4 8 18 71 118 73 39 10 8 0 349 NNE 0 6 15 29 69 42 30 15 6 2 3 217 NE 0 8 9 22 67 73 65 44 87 53 6 434 ENE 0 2 5 16 59 60 70 78 67 47 11 415 E 0 6 6 11 49 62 45 40 27 11 0 257 ESE 0 1 5 12 56 67 51 29 7 2 0 230 SE 0 2 9 10 58 67 75 40 11 2 1 275 SSE 0 4 4 11 57 49 63 53 42 7 3 293 S 0 4 6 14 60 101 110 99 110 25 12 541 SSW 0 2 7 19 73 167 160 156 169 48 26 827 SW 0 5 6 17 74 145 233 179 87 17 1 764 WSW 0 0 7 21 67 112 255 203 87 15 0 767 W 0 3 11 13 47 135 246 224 108 21 16 824 WNW 0 2 8 15 54 112 215 285 232 103 36 1062 NW 1 5 11 11 54 110 215 218 202 61 27 915 NNW 0 2 9 14 47 97 119 131 99 20 0 538 Tot 1 56 126 253 962 1517 2025 1833 1351 442 142 8708 Hours of Calm . . . . . . . 1 Hours of Variable Direction 0 Hours of Valid Data . . . . 8709 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 92

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Extremely Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 1 0 4 8 5 4 0 0 0 22 NNE 0 0 1 1 4 10 3 4 0 0 0 23 NE 0 0 0 1 3 13 31 15 5 8 0 76 ENE 0 0 0 1 4 14 28 36 27 5 0 115 E 0 0 0 1 4 15 17 13 7 0 0 57 ESE 0 0 0 1 10 26 26 8 1 0 0 72 SE 0 0 2 0 7 17 50 26 1 0 0 103 SSE 0 0 0 0 2 9 21 36 17 0 0 85 S 0 0 0 0 3 8 22 47 58 14 3 155 SSW 0 0 0 0 3 10 12 21 45 19 3 113 SW 0 0 0 1 10 23 21 18 13 6 0 92 WSW 0 0 2 2 8 18 37 45 34 8 0 154 W 0 0 1 0 8 28 36 17 27 11 5 133 WNW 0 0 0 0 10 20 29 36 53 47 13 208 NW 0 0 0 2 10 22 41 39 65 15 12 206 NNW 0 0 0 1 6 14 12 14 10 2 0 59 Tot 0 0 7 11 96 255 391 379 363 135 36 1673 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 1673 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 93

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Moderately Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 0 0 2 2 5 1 0 0 0 10 NNE 0 0 0 1 2 2 0 0 0 0 0 5 NE 0 0 0 0 5 2 2 1 6 2 0 18 ENE 0 0 0 0 5 4 7 5 2 4 0 27 E 0 0 0 1 5 3 5 1 3 2 0 20 ESE 0 0 0 0 1 3 2 2 0 0 0 8 SE 0 0 0 0 3 5 2 2 0 0 0 12 SSE 0 0 0 1 1 4 6 2 9 0 0 23 S 0 0 0 0 0 6 5 2 1 2 0 16 SSW 0 0 0 1 1 1 2 4 8 3 2 22 SW 0 0 0 1 2 0 4 3 2 2 0 14 WSW 0 0 0 2 5 4 7 6 8 2 0 34 W 0 0 1 0 5 5 11 4 7 2 2 37 WNW 0 0 1 2 2 4 7 4 21 10 4 55 NW 0 0 1 0 1 5 3 10 16 10 5 51 NNW 0 0 0 0 4 5 2 7 9 4 0 31 Tot 0 0 3 9 44 55 70 54 92 43 13 383 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 383 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 94

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Slightly Unstable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 0 0 1 1 0 1 0 0 0 3 NNE 0 0 0 0 1 0 1 0 0 0 0 2 NE 0 0 0 1 1 2 2 2 2 2 0 12 ENE 0 0 0 0 1 4 3 5 0 2 0 15 E 0 0 0 1 1 3 1 0 1 0 0 7 ESE 0 0 0 0 6 2 1 0 0 0 0 9 SE 0 0 0 0 2 2 1 0 0 0 0 5 SSE 0 0 0 0 1 1 4 3 0 0 0 9 S 0 0 0 0 1 1 3 1 1 1 1 9 SSW 0 0 0 1 1 0 4 7 3 1 0 17 SW 0 0 0 0 2 3 3 0 2 0 0 10 WSW 0 0 1 1 3 2 2 4 2 1 0 16 W 0 0 1 0 2 3 5 4 10 1 1 27 WNW 0 0 0 2 2 1 7 9 6 2 2 31 NW 0 0 0 1 1 4 2 7 9 2 2 28 NNW 0 0 0 0 1 1 1 0 4 2 0 9 Tot 0 0 2 7 27 30 40 43 40 14 6 209 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 209 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 95

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Neutral - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 2 5 15 23 12 7 2 0 0 66 NNE 0 0 2 4 12 12 19 4 0 0 0 53 NE 0 1 0 0 6 17 11 10 24 13 4 86 ENE 0 0 2 5 17 8 10 11 13 17 4 87 E 0 2 0 0 11 11 7 5 4 3 0 43 ESE 0 0 0 4 15 14 6 12 4 0 0 55 SE 0 0 1 5 17 17 12 8 9 0 0 69 SSE 0 0 0 5 8 9 14 4 10 1 0 51 S 0 0 0 5 12 23 30 22 29 3 3 127 SSW 0 0 0 5 10 14 36 46 44 5 15 175 SW 0 0 2 3 8 16 20 15 17 3 0 84 WSW 0 0 1 2 15 10 12 15 11 2 0 68 W 0 0 1 4 7 20 26 14 24 3 3 102 WNW 0 0 0 2 7 13 28 23 28 21 9 131 NW 0 0 3 0 9 17 22 26 43 22 4 146 NNW 0 0 2 3 9 19 12 15 13 7 0 80 Tot 0 3 16 52 178 243 277 237 275 100 42 1423 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 1423 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 96

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Slightly Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 1 1 4 21 29 18 12 8 8 0 102 NNE 0 1 5 5 15 15 6 7 6 2 3 65 NE 0 2 1 6 16 26 16 14 49 27 2 159 ENE 0 2 0 3 13 21 19 18 25 19 7 127 E 0 2 2 3 13 21 13 20 12 6 0 92 ESE 0 1 4 2 10 19 15 7 2 2 0 62 SE 0 1 4 2 14 16 9 4 1 2 1 54 SSE 0 3 0 1 23 12 18 8 6 6 3 80 S 0 2 2 2 21 31 33 25 21 5 5 147 SSW 0 1 3 6 38 76 76 67 68 20 6 361 SW 0 1 1 2 24 59 125 105 47 6 1 371 WSW 0 0 1 6 17 42 98 55 28 2 0 249 W 0 2 0 4 10 40 65 68 27 4 4 224 WNW 0 0 1 5 14 42 70 103 97 23 8 363 NW 0 1 5 1 17 35 75 62 59 12 4 271 NNW 0 2 0 7 15 36 50 44 48 5 0 207 Tot 0 22 30 59 281 520 706 619 504 149 44 2934 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 2934 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 97

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Moderately Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 0 1 4 8 10 8 5 0 0 0 36 NNE 0 1 2 2 7 0 1 0 0 0 0 13 NE 0 3 3 2 7 4 2 1 1 1 0 24 ENE 0 0 0 0 6 3 0 2 0 0 0 11 E 0 0 1 1 2 3 0 0 0 0 0 7 ESE 0 0 0 0 5 1 0 0 0 0 0 6 SE 0 0 0 0 4 5 1 0 0 0 0 10 SSE 0 0 1 1 8 9 0 0 0 0 0 19 S 0 1 0 2 8 19 7 2 0 0 0 39 SSW 0 0 1 0 9 24 8 3 0 0 0 45 SW 0 0 2 4 12 15 36 19 3 0 0 91 WSW 0 0 1 0 7 15 42 35 2 0 0 102 W 0 0 2 0 3 14 44 52 6 0 1 122 WNW 0 0 1 1 5 17 37 47 12 0 0 120 NW 0 0 0 1 8 7 28 31 1 0 0 76 NNW 0 0 2 0 5 9 14 27 5 0 0 62 Tot 0 5 17 18 104 155 228 224 30 1 1 783 Hours of Calm . . . . . . . 0 Hours of Variable Direction 0 Hours of Valid Data . . . . 783 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 98

Oyster Creek 2013 Annual Radioactive Effluent Release Report Table D - 10 Wind Speed by Direction Measured at 380 Feet for various Stability Classes for the Oyster Creek Generating Station, January - December, 2013 Oyster Creek Alpha Period of Record: January - December 2013 Stability Class - Extremely Stable - 380Ft-33Ft Delta-T (F)

Winds Measured at 380 Feet Wind Wind Speed (in m/s)

Direction 0.5- 1.1- 1.6- 2.1- 3.1- 4.1- 5.1- 6.1- 8.1-Sector <0.50 1 1.5 2 3 4 5 6 8 10 >10.00 Total N 0 3 3 5 20 45 25 9 0 0 0 110 NNE 0 4 5 16 28 3 0 0 0 0 0 56 NE 0 2 5 12 29 9 1 1 0 0 0 59 ENE 0 0 3 7 13 6 3 1 0 0 0 33 E 0 2 3 4 13 6 2 1 0 0 0 31 ESE 0 0 1 5 9 2 1 0 0 0 0 18 SE 0 1 2 3 11 5 0 0 0 0 0 22 SSE 0 1 3 3 14 5 0 0 0 0 0 26 S 0 1 4 5 15 13 10 0 0 0 0 48 SSW 0 1 3 6 11 42 22 8 1 0 0 94 SW 0 4 1 6 16 29 24 19 3 0 0 102 WSW 0 0 1 8 12 21 57 43 2 0 0 144 W 0 1 5 5 12 25 59 65 7 0 0 179 WNW 0 2 5 3 14 15 37 63 15 0 0 154 NW 1 4 2 6 8 20 44 43 9 0 0 137 NNW 0 0 5 3 7 13 28 24 10 0 0 90 Tot 1 26 51 97 232 259 313 277 47 0 0 1303 Hours of Calm . . . . . . . 1 Hours of Variable Direction 0 Hours of Valid Data . . . . 1304 Hours of Missing Data . . . 51 Hours in Period . . . . . . 8760 99

Oyster Creek 2013 Annual Radioactive Effluent Release Report Appendix E ODCM Revisions None 100

Oyster Creek 2013 Annual Radioactive Effluent Release Report Appendix F ERRATA 101

Oyster Creek 2013 Annual Radioactive Effluent Release Report Correction to 2012 ARERR There were two issues discovered in 2013 that impacted the amount of Curies released reported in Table A-2 but did not impact any of the Curies released in summary of all releases in Table A-1 nor any of the doses reported Appendix C, Radiological Impact to Man. No limits were exceeded.

1. During performance of the annual Augmented Off Gas (AOG) sample line pressure test per Work Order R2200914 it was discovered that there were two leaks in the sample line that diluted the sample flow from what was used to perform the original release calculations. One leak was the seal where the detector goes into the chamber; the second leak was a small leak directly downstream of an inlet isolation valve. A review determined that these leaks first occurred 8/30/2012 and continued until repairs were completed 5/2/2013.

These leaks only impact the particulate and iodine sampling from the normal sample point. All particulate and iodine samples taken during this time period were evaluated and updated based on the calculated sample flow rate provided by Engineering.

2. During the performance of Work Order R2205683, which is to perform an annual inspection of the stack pad exhaust fans, three slits were discovered in the top boot of exhaust fan EF-1-16 and a bolt was missing from exhaust fan EF-1-17.

These are the two exhaust fans for the Old Radwaste Building to the Main Stack. One of these two exhaust fans is in operation at all times to maintain a negative pressure in the Old Radwaste Building. At no times do both of these fans run simultaneously as each fans is designed to provide 100% of the required flow. Engineering performed a calculation to determine a release rate that encompasses the maximum release rate regardless of which exhaust fan is in service. Since the activity to inspect the exhaust fans is an annual activity, it was conservatively assumed that both exhaust fans have been leaking since the date of the last inspection until the time the repairs were completed, 7/29/12 through 7/25/13. Also, a conservative approach to determining dose to the public was taken that assumed that all of the activity due to particulates reported from the Main Stack was coming from the Old Radwaste Building and therefore being released as a groundlevel release from the exhaust fan leaks at the flow rate calculated by Engineering.

102

Oyster Creek 2013 Annual Radioactive Effluent Release Report ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 1, 2012 through December 31, 2012 EXELON GENERATION COMPANY, LLC OYSTER CREEK GENERATING STATION DOCKET NO. 50-219 (Oyster Creek Generating Station)

DOCKET NO. 72-15 (Independent Spent Fuel Storage Facility)

Submitted to The United States Nuclear Regulatory Commission Pursuant to Renewed Facility Operating License DPR-16 103

Oyster Creek 2013 Annual Radioactive Effluent Release Report ORIGINAL PAGE Table A-3: Gaseous Effluent Release Point: Ground Level Releases Period: January 1, 2012 through December 31, 2012 Unit: Oyster Creek Nuclides Released Continuous Mode Batch Mode

1. Fission gases Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Kr- 85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr- 85m Ci <LLD <LLD 1.87E-02 <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD 1.01E-02 <LLD <LLD <LLD <LLD <LLD Xe-133 Ci <LLD <LLD 9.26E-01 5.33E-02 <LLD <LLD <LLD <LLD Xe-133m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci <LLD <LLD 9.55E-01 5.33E-02 <LLD <LLD <LLD <LLD
2. Iodines I-131 Ci 1.24E-07 1.58E-07 2.84E-07 8.12E-06 <LLD <LLD <LLD <LLD I-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD I-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 1.24E-07 1.58E-07 2.84E-07 8.12E-06 <LLD <LLD <LLD <LLD
3. Particulates Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mn-54 Ci <LLD 5.04E-07 1.17E-06 3.63E-06 <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD 1.65E-07 2.92E-07 <LLD <LLD <LLD <LLD Co-60 Ci 1.06E-06 5.63E-06 6.81E-06 1.12E-05 <LLD <LLD <LLD <LLD Ni-63 Ci <LLD <LLD 2.75E-05 4.15E-05 <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-55 Ci 6.96E-03 6.97E-03 4.61E-03 <LLD <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Am-241 Ci <LLD <LLD <LLD 4.94E-06 <LLD <LLD <LLD <LLD Total for Period Ci 6.96E-03 6.98E-03 4.65E-03 6.16E-05 <LLD <LLD <LLD <LLD
4. Tritium H-3 Ci 1.87E-01 3.62E-01 6.00E-01 4.75E-01 <LLD <LLD <LLD <LLD
5. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD
6. Carbon-14 C-14 Ci 7.48E-02 7.41E-02 7.57E-02 7.57E-02 <LLD <LLD <LLD <LLD 104

Oyster Creek 2013 Annual Radioactive Effluent Release Report CORRECTED PAGE Table A-3: Gaseous Effluent Release Point: Ground Level Releases Period: January 1, 2012 through December 31, 2012 Unit: Oyster Creek Nuclides Released Continuous Mode Batch Mode

1. Fission gases Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Kr- 85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr- 85m Ci <LLD <LLD 1.87E-02 <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD 1.01E-02 <LLD <LLD <LLD <LLD <LLD Xe-133 Ci <LLD <LLD 9.26E-01 5.33E-02 <LLD <LLD <LLD <LLD Xe-133m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci <LLD <LLD 9.55E-01 5.33E-02 <LLD <LLD <LLD <LLD
2. Iodines I-131 Ci 1.24E-07 1.58E-07 2.84E-07 8.12E-06 <LLD <LLD <LLD <LLD I-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD I-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 1.24E-07 1.58E-07 2.84E-07 8.12E-06 <LLD <LLD <LLD <LLD
3. Particulates Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD 1.80E-07 2.62E-07 <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD 1.83E-05 2.68E-05 <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD 3.71E-06 5.41E-06 <LLD <LLD <LLD <LLD Mn-54 Ci <LLD 5.04E-07 4.24E-06 8.11E-06 <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD 2.87E-06 4.24E-06 <LLD <LLD <LLD <LLD Co-60 Ci 1.06E-06 5.63E-06 1.15E-05 1.80E-05 <LLD <LLD <LLD <LLD Ni-63 Ci <LLD <LLD 2.75E-05 4.15E-05 <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD 5.57E-07 8.14E-07 <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-55 Ci 6.96E-03 6.97E-03 4.61E-03 <LLD <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD 1.46E-06 2.14E-06 <LLD <LLD <LLD <LLD Am-241 Ci <LLD <LLD <LLD 4.94E-06 <LLD <LLD <LLD <LLD Total for Period Ci 6.96E-03 6.98E-03 4.68E-03 1.12E-04 <LLD <LLD <LLD <LLD
4. Tritium H-3 Ci 1.87E-01 3.62E-01 6.00E-01 4.75E-01 <LLD <LLD <LLD <LLD
5. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD
6. Carbon-14 C-14 Ci 7.48E-02 7.41E-02 7.57E-02 7.57E-02 <LLD <LLD <LLD <LLD 105