ML14141A048

From kanterella
Jump to navigation Jump to search
Attachment 1, Kld TR-635, Rev. 0, Development of Evacuation Time Estimates. Part 1 of 4
ML14141A048
Person / Time
Site: Braidwood  
Issue date: 04/28/2014
From:
KLD Engineering, PC
To:
Document Control Desk, NRC/FSME, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
Shared Package
ML14141A046 List:
References
RS-14-151 KLD TR-635, Rev. 0
Download: ML14141A048 (113)


Text

Attachment 1 Braidwood Generating Station Development of Evacuation Time Estimates

BRAID WOOD GENERATING STATION Development of Evacuation Time Estimates Work performed for Exelon Generation, by:

KLD Engineering, P.C.

1601 Veterans Memorial Highway, Suite 340 Islandia, NY 11749 mailto: kweinisch@kldcompanies.com April 28, 2014 Final Report, Rev. 0 KLD TR - 635

Table of Contents 1

INTRODUCTIO N..................................................................................................................................

1-1 1.1 Overview of the ETE Process......................................................................................................

1-1 1.2 The Braidw ood Generating Station Location.............................................................................

1-3 1.3 Prelim inary Activities.................................................................................................................

1-5 1.4 Com parison w ith Prior ETE Study..............................................................................................

1-9 2

STUDY ESTIM ATES AND ASSUM PTIO NS.............................................................................................

2-1 2.1 Data Estim ates...........................................................................................................................

2-1 2.2 Study M ethodological Assum ptions..........................................................................................

2-2 2.3 Study Assum ptions.....................................................................................................................

2-5 3

DEM AND ESTIM ATION.......................................................................................................................

3-1 3.1 Perm anent Residents.................................................................................................................

3-2 3.1.1 Special Facilities.................................................................................................................

3-2 3.2 Shadow Population....................................................................................................................

3-8 3.3 Transient Population................................................................................................................

3-11 3.4 Em ployees................................................................................................................................

3-15 3.5 M edical Facilities......................................................................................................................

3-19 3.6 Total Dem and in Addition to Perm anent Population..............................................................

3-19 3.7 Special Event............................................................................................................................

3-19 3.8 Sum m ary of Dem and...............................................................................................................

3-22 4

ESTIM ATION OF HIGHW AY CAPACITY................................................................................................

4-1 4.1 Capacity Estim ations on Approaches to Intersections..............................................................

4-2 4.2 Capacity Estim ation along Sections of Highw ay........................................................................

4-4 4.3 Application to the BW D Study Area...........................................................................................

4-6 4.3.1 Tw o-Lane Roads.................................................................................................................

4-6 4.3.2 M ulti-Lane Highw ay...........................................................................................................

4-6 4.3.3 Freew ays............................................................................................................................

4-7 4.3.4 Intersections......................................................................................................................

4-8 4.4 Sim ulation and Capacity Estim ation..........................................................................................

4-8 5

ESTIM ATION OF TRIP GENERATION TIM E..........................................................................................

5-1 5.1 Background................................................................................................................................

5-1 5.2 Fundam ental Considerations.....................................................................................................

5-3 5.3 Estim ated Tim e Distributions of Activities Preceding Event 5...................................................

5-6 5.4 Calculation of Trip Generation Tim e Distribution....................................................................

5-11 5.4.1 Statistical Outliers............................................................................................................

5-12 5.4.2 Staged Evacuation Trip Generation.................................................................................

5-15 5.4.3 Trip Generation for W aterw ays and Recreational Areas.................................................

5-17 6

DEM AND ESTIM ATION FOR EVACUATION SCENARIOS.....................................................................

6-1 7

GENERAL POPULATION EVACUATION TIM E ESTIM ATES (ETE)..........................................................

7-1 7.1 Voluntary Evacuation and Shadow Evacuation.........................................................................

7-1 7.2 Staged Evacuation......................................................................................................................

7-1 Braidwood Generating Station i

KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

7.3 Patterns of Traffic Congestion during Evacuation.....................................................................

7-2 7.4 Evacuation Rates........................................................................................................................

7-3 7.5 Evacuation Tim e Estim ate (ETE) Results....................................................................................

7-4 7.6 Staged Evacuation Results.........................................................................................................

7-6 7.7 Guidance on Using ETE Tables...................................................................................................

7-6 8

TRANSIT-DEPENDENT AND SPECIAL FACILITY EVACUATION TIME ESTIMATES.................................

8-1 8.1 Transit Dependent People Dem and Estim ate............................................................................

8-2 8.2 School, Pre-School and Day Cam p Population - Transit Dem and.............................................

8-3 8.3 M edical Facility Dem and............................................................................................................

8-4 8.4 Evacuation Tim e Estim ates for Transit Dependent People.......................................................

8-4 8.5 Special Needs Population...........................................................................................................

8-9 8.6 Correctional Facilities...............................................................................................................

8-10 9

TRAFFIC M ANAGEM ENT STRATEGY...................................................................................................

9-1 10 EVACUATION ROUTES..................................................................................................................

10-i 11 SURVEILLANCE OF EVACUATION OPERATIONS...........................................................................

11-i 12 CONFIRM ATION TIM E..................................................................................................

.... 12-1 13 References...................................................................................................................................

13-1 List of Appendices A.

GLOSSARY OF TRAFFIC ENGINEERING TERM S..............................................................................

A-i B.

DYNAM IC TRAFFIC ASSIGNM ENT AND DISTRIBUTION M ODEL...................................................

B-i C.

DYNEV TRAFFIC SIM ULATION M ODEL..........................................................................................

C-i C.i M ethodology..............................................................................................................................

C-5 C.1.1 The Fundam ental Diagram............................................................................................

C-5 C.1.2 The Sim ulation M odel...................................................................................................

C-5 C.1.3 Lane Assignm ent.......................................................................................................

C-12 C.2 Im plem entation.......................................................................................................................

C-12 C.2.1 Com putational Procedure................................................................................................

C-12 C.2.2 Interfacing w ith Dynam ic Traffic Assignm ent (DTRAD)..............................................

C-iS D.

DETAILED DESCRIPTION OF STUDY PROCEDURE..........................................................................

D-i E.

SPECIAL FACILITY DATA......................................................................................................................

E-1 F.

TELEPHONE SURVEY...........................................................................................................................

F-i F.1 Introduction...............................................................................................................................

F-i F.2 Survey Results............................................................................................................................

F-1 F.2.1 Household Dem ographic Results...........................................................................................

F-2 F.2.2 Evacuation Response.............................................................................................................

F-4 F.2.3 Tim e Distribution Results.......................................................................................................

F-6 F.3 Conclusions................................................................................................................................

F-9 G.

TRAFFIC M ANAGEM ENT PLAN.....................................................................................................

G-1 Braidwood Generating Station ii KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

G.1 Traffic Control Points................................................................................................................

G-i G.2 Access Control Points................................................................................................................

G-1 H.

EVACUATION REGIONS.....................................................................................................................

H-1 J.

REPRESENTATIVE INPUTS TO AND OUTPUTS FROM THE DYNEV II SYSTEM.................................. J-K.

EVACUATION ROADWAY NETWORK............................................................................................

K-i L.

Sub-area BO U N D A R IES......................................................................................................................

L-1 M.

EVACUATION SENSITIVITY STUDIES..........................................................................................

M-1 M.1 Effect of Changes in Trip Generation Times.......................................................................

M-2 M.2 Effect of Changes in the Number of People in the Shadow Region W ho Relocate................. M-2 M.3 Effect of Changes in EPZ Resident Population.........................................................................

M-3 M.4 Enhancements in Evacuation Time..........................................................................................

M-4 N.

ETE CRITERIA CHECKLIST...................................................................................................................

N-i Note: Appendix I intentionally skipped Braidwood Generating Station iii KLD Engineering, P.C.

Fvacuafinn Time F-,timatp Rev. 0

List of Figures Figure 1-1. BW D Locatio n.........................................................................................................................

1-4 Figure 1-2. BWD Link-Node Analysis Network..........................................................................................

1-7 Figure 2-1. Voluntary Evacuation Methodology.......................................................................................

2-4 Fig u re 3-1. BW D E PZ.................................................................................................................................

3 -3 Figure 3-2. Permanent Resident Population by Sector.............................................................................

3-6 Figure 3-3. Permanent Resident Vehicles by Sector.................................................................................

3-7 Figure 3-4. Shadow Population by Sector.................................................................................................

3-9 Figure 3-5. Shadow Vehicles by Sector...................................................................................................

3-10 Figure 3-6. Transient Population by Sector.............................................................................................

3-13 Figure 3-7. Transient Vehicles by Sector.................................................................................................

3-14 Figure 3-8. Employee Population by Sector............................................................................................

3-17 Figure 3-9. Em ployee Vehicles by Sector................................................................................................

3-18 Figure 4-1. Fundam ental D iagram s............................................................................................................

4-9 Figure 5-1. Events and Activities Preceding the Evacuation Trip..............................................................

5-5 Figure 5-2. Evacuation Mobilization Activities........................................................................................

5-10 Figure 5-3. Comparison of Data Distribution and Normal Distribution......................................................

5-14 Figure 5-4. Comparison of Trip Generation Distributions.......................................................................

5-18 Figure 5-5. Comparison of Staged and Un-staged Trip Generation Distributions in the 2 to 5 M ile R eg io n....................................................................................................................................

5-20 Figure 6-1. BW D EPZ Sub-areas.................................................................................................................

6-6 Figure 7-1. Voluntary Evacuation Methodology.....................................................................................

7-19 Figure 7-2. BW D Shadow Region............................................................................................................

7-20 Figure 7-3. Congestion Patterns at 1 Hour after the Advisory to Evacuate............................................

7-21 Figure 7-4. Congestion Patterns at 1 Hour and 25 Minutes after the Advisory to Evacuate.................. 7-22 Figure 7-5. Congestion Patterns at 2 Hours after the Advisory to Evacuate..........................................

7-23 Figure 7-6. Congestion Patterns at 3 Hours after the Advisory to Evacuate..........................................

7-24 Figure 7-7. Congestion Patterns at 3 Hours and 30 Minutes after the Advisory to Evacuate................ 7-25 Figure 7-8. Evacuation Time Estimates - Scenario 1 for Region R03......................................................

7-26 Figure 7-9. Evacuation Time Estimates - Scenario 2 for Region R03......................................................

7-26 Figure 7-10. Evacuation Time Estimates - Scenario 3 for Region R03....................................................

7-27 Figure 7-11. Evacuation Time Estimates - Scenario 4 for Region R03....................................................

7-27 Figure 7-12. Evacuation Time Estimates - Scenario 5 for Region R03....................................................

7-28 Figure 7-13. Evacuation Time Estimates - Scenario 6 for Region R03....................................................

7-28 Figure 7-14. Evacuation Time Estimates - Scenario 7 for Region R03....................................................

7-29 Figure 7-15. Evacuation Time Estimates - Scenario 8 for Region R03....................................................

7-29 Figure 7-16. Evacuation Time Estimates - Scenario 9 for Region R03....................................................

7-30 Figure 7-17. Evacuation Time Estimates - Scenario 10 for Region R03..................................................

7-30 Figure 7-18. Evacuation Time Estimates - Scenario 11 for Region R03..................................................

7-31 Figure 7-19. Evacuation Time Estimates - Scenario 12 for Region R03..................................................

7-31 Figure 7-20. Evacuation Time Estimates - Scenario 13 for Region R03..................................................

7-32 Figure 7-21. Evacuation Time Estimates - Scenario 14 for Region R03..................................................

7-32 Figure 8-1. Chronology of Transit Evacuation Operations......................................................................

8-11 Figure 8-2. BWD Transit Dependent Bus Routes....................................................................................

8-12 Figure 10-1. General Population Reception Communities and Reception Centers................................

10-2 Figure 10-2. M ajor Evacuation Routes....................................................................................................

10-3 Braidwood Generating Station iv KLD Engineering. P.C.

Fvacuation Time Fstimate Rev. 0

Figure B-i. Flow Diagram of Sim ulation-DTRAD Interface........................................................................

B-5 Figure C-1. Representative Analysis Network...........................................................................................

C-4 Figure C-2. Fundam ental Diagram s...........................................................................................................

C-6 Figure C-3. A UNIT Problem Configuration w ith t1 > 0..............................................................................

C-6 Figure C-4. Flow of Sim ulation Processing (See Glossary: Table C-3)..............................................

C-14 Figure D-1. Flow Diagram of Activities.....................................................................................................

D-5 Figure E-i. Schools w ithin the BW D EPZ...................................................................................................

E-8 Figure E-2. Preschools and Day Cam ps w ithin the BW D EPZ....................................................................

E-9 Figure E-3. M edical and Correctional Facilities within the BW D EPZ..................................................

E-10 Figure E-4. Em ployers w ithin the BW D EPZ.......................................................................................

E-11 Figure E-5. Recreational Areas within the BW D EPZ..........................................................................

E-12 Figure E-6. Lodging Facilities w ithin the BW D EPZ.............................................................................

E-13 Figure F-1. Household Size in the EPZ.......................................................................................................

F-2 Figure F-2. Household Vehicle Availability................................................................................................

F-2 Figure F-3. Com m uters in Households in the EPZ.....................................................................................

F-3 Figure F-4. Num ber of Vehicles Used for Evacuation...............................................................................

F-4 Figure F-5. Com m uter Evacuation Response.............................................................................................

F-5 Figure F-6. Tim e Required to Prepare to Leave W ork...............................................................................

F-6 Figure F-7. W ork to Hom e Travel Tim e.....................................................................................................

F-7 Figure F-8. Tim e to Prepare Hom e for Evacuation....................................................................................

F-8 Figure F-9. Tim e to Clear Driveway of 6"-8" of Snow...............................................................................

F-9 Figure G-1. Traffic and Access Control Points for the Braidwood Generating Station............................

G-2 Figure H-1. Region R01.............................................................................................................................

H-4 Figure H-2. Region R02.............................................................................................................................

H-5 Figure H-3. Region R03.............................................................................................................................

H-6 Figure H-4. Region R04.............................................................................................................................

H-7 Figure H-5. Region R05.............................................................................................................................

H-8 Figure H-6. Region R06.............................................................................................................................

H-9 Figure H-7. Region R07...........................................................................................................................

H-iO Figure H-8. Region R08...........................................................................................................................

H-11 Figure H-9. Region R09...........................................................................................................................

H-12 Figure H-10. Region RiO.........................................................................................................................

H-13 Figure H-11. Region Ri1.........................................................................................................................

H-14 Figure H-12. Region R12.........................................................................................................................

H-15 Figure H-13. Region R13.........................................................................................................................

H-16 Figure H-14. Region R14.........................................................................................................................

H-17 Figure H-iS. Region Ri5.........................................................................................................................

H-18 Figure H-16. Region R16.........................................................................................................................

H-19 Figure H-17. Region R17.........................................................................................................................

H-20 Figure H-18. Region R18.........................................................................................................................

H-21 Figure H-19. Region R19.........................................................................................................................

H-22 Figure H-20. Region R20.........................................................................................................................

H-23 Figure H-21. Region R21.........................................................................................................................

H-24 Figure H-22. Region R22.........................................................................................................................

H-25 Figure H-23. Region R23.........................................................................................................................

H-26 Figure H-24. Region R24.........................................................................................................................

H-27 Figure H-25. Region R25.........................................................................................................................

H-28 Braidwood Generating Station v

KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure H -26. Regio n R26.........................................................................................................................

H -29 Figure H -27. Regio n R27.........................................................................................................................

H -30 Figure H -28. Regio n R28.........................................................................................................................

H -3 1 Figure H -29. Regio n R29.........................................................................................................................

H -32 Figure H -30. Regio n R30.........................................................................................................................

H -33 Figure H -3 1. Regio n R3 1.........................................................................................................................

H -34 Figure H -32. Regio n R32.........................................................................................................................

H -35 Figure H -33. Regio n R33.........................................................................................................................

H -36 Figure H -34. Regio n R34.........................................................................................................................

H -37 Figure H -35. Regio n R35.........................................................................................................................

H -38 Figure H -36. Regio n R36.........................................................................................................................

H -39 Figure H -37. Regio n R37.........................................................................................................................

H -40 Figure H -38. Regio n R38.........................................................................................................................

H -4 1 Figure J-1. ETE and Trip Generation: Summer, Midweek, Midday, Good Weather (Scenario 1)............ J-10 Figure J-2. ETE and Trip Generation: Summer, Midweek, Midday, Rain (Scenario 2).............................

J-10 Figure J-3. ETE and Trip Generation: Summer, Weekend, Midday, Good Weather (Scenario 3)............ J-11 Figure J-4. ETE and Trip Generation: Summer, Weekend, Midday, Rain (Scenario 4)............................

J-11 Figure J-5. ETE and Trip Generation: Summer, Midweek, Weekend, Evening, Good Weather (S ce n a rio 5 )..............................................................................................................................................

J-1 2 Figure J-6. ETE and Trip Generation: Winter, Midweek, Midday, Good Weather (Scenario 6).............. J-12 Figure J-7. ETE and Trip Generation: Winter, Midweek, Midday, Rain (Scenario 7)...............................

J-13 Figure J-8. ETE and Trip Generation: Winter, Midweek, Midday, Snow (Scenario 8).............................

J-13 Figure J-9. ETE and Trip Generation: Winter, Weekend, Midday, Good Weather (Scenario 9).............. J-14 Figure J-10. ETE and Trip Generation: Winter, Weekend, Midday, Rain (Scenario 10)...........................

J-14 Figure J-11. ETE and Trip Generation: Winter, Weekend, Midday, Snow (Scenario 11).........................

J-15 Figure J-12. ETE and Trip Generation: Winter, Midweek, Weekend, Evening, Good Weather (S ce n a rio 1 2 )............................................................................................................................................

J-1 5 Figure J-13. ETE and Trip Generation: Winter, Midweek, Midday, Good Weather, Special Event (S ce n a rio 1 3 )............................................................................................................................................

J-1 6 Figure J-14. ETE and Trip Generation: Summer, Midweek, Midday, Good Weather, Roadway Impact (S ce n a rio 14 )............................................................................................................................................

J-1 6 Figure K-1. Braidwood Generating Station Link-Node Analysis Network.................................................

K-2 Figure K-2. Link-Node Analysis Network-Grid 1......................................................................................

K-3 Figure K-3. Link-Node Analysis Network - Grid 2......................................................................................

K-4 Figure K-4. Link-Node Analysis Network - Grid 3................................................................................

K-5 Figure K-5. Link-Node Analysis Network - Grid 4......................................................................................

K-6 Figure K-6. Link-Node Analysis Network - Grid 5......................................................................................

K-7 Figure K-7. Link-Node Analysis Network-Grid 6......................................................................................

K-8 Figure K-8. Link-Node Analysis Network - Grid 7......................................................................................

K-9 Figure K-9. Link-Node Analysis Network - Grid 8....................................................................................

K-10 Figure K-10. Link-Node Analysis Network - Grid 9............................................................................

K-11 Figure K-11. Link-Node Analysis Network - Grid 10................................................................................

K-12 Figure K-12. Link-Node Analysis Network - Grid 11...............................................................................

K-13 Figure K-13. Link-Node Analysis Network - Grid 12................................................................................

K-14 Figure K-14. Link-Node Analysis Network - Grid 13............................................................................

K-15 Figure K-15. Link-Node Analysis Network-Grid 14............................................................................

K-16 Figure K-16. Link-Node Analysis Network -Grid 15................................................................................

K-17 Braidwood Generating Station vi KID Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure K-17. Link-Node Analysis Network - Grid 16................................................................................

K-18 Figure K-18. Link-Node Analysis Network -Grid 17................................................................................

K-19 Figure K-19. Link-Node Analysis Network - Grid 18................................................................................

K-20 Figure K-20. Link-Node Analysis Network - Grid 19................................................................................

K-21 Figure K-21. Link-Node Analysis Network - Grid 20................................................................................

K-22 Figure K-22. Link-Node Analysis Network - Grid 21................................................................................

K-23 Figure K-23. Link-Node Analysis Network - Grid 22................................................................................

K-24 Figure K-24. Link-Node Analysis Network - Grid 23................................................................................

K-25 Figure K-25. Link-Node Analysis Network-Grid 24................................................................................

K-26 Figure K-26. Link-Node Analysis Network - Grid 25................................................................................

K-27 Figure K-27. Link-Node Analysis Network-Grid 26................................................................................

K-28 Figure K-28. Link-Node Analysis Network - Grid 27................................................................................

K-29 Figure K-29. Link-Node Analysis Network - Grid 28................................................................................

K-30 Figure K-30. Link-Node Analysis Network - Grid 29................................................................................

K-31 Figure K-31. Link-Node Analysis Network - Grid 30................................................................................

K-32 Figure K-32. Link-Node Analysis Network - Grid 31................................................................................

K-33 Figure K-33. Link-Node Analysis Network - Grid 32................................................................................

K-34 Figure K-34. Link-Node Analysis Network - Grid 33................................................................................

K-35 Figure K-35. Link-Node Analysis Network - Grid 34................................................................................

K-36 Figure K-36. Link-Node Analysis Network - Grid 35................................................................................

K-37 Figure K-37. Link-Node Analysis Network - Grid 36................................................................................

K-38 Figure K-38. Link-Node Analysis Network-Grid 37................................................................................

K-39 Figure K-39. Link-Node Analysis Network - Grid 38................................................................................

K-40 Figure K-40. Link-Node Analysis Network - Grid 39................................................................................

K-41 Figure K-41. Link-Node Analysis Network - Grid 40................................................................................

K-42 Figure K-42. Link-Node Analysis Network-Grid 41................................................................................

K-43 Figure K-43. Link-Node Analysis Network - Grid 42................................................................................

K-44 Figure K-44. Link-Node Analysis Network - Grid 43................................................................................

K-45 Figure K-45. Link-Node Analysis Network - Grid 44................................................................................

K-46 Figure K-46. Link-Node Analysis Network-Grid 45................................................................................

K-47 Braidwood Generating Station vii KLD Engineering, P.C.

Fvartiation Timp Fstimatp Rev. 0

List of Tables Table 1-1. Stakeholder Interaction...........................................................................................................

1-1 Table 1-2. H ighw ay Characteristics...........................................................................................................

1-5 Table 1-3. ETE Study Com parisons............................................................................................................

1-9 Table 2-1. Evacuation Scenario Definitions...............................................................................................

2-3 Table 2-2. M odel Adjustm ent for Adverse W eather.................................................................................

2-6 Table 3-1. EPZ Perm anent Resident Population.......................................................................................

3-4 Table 3-2. Permanent Resident Population and Vehicles by Sub-area.....................................................

3-5 Table 3-3. Shadow Population and Vehicles by Sector.............................................................................

3-8 Table 3-4. Sum m ary of Transients and Transient Vehicles.....................................................................

3-12 Table 3-5. Summary of Non-EPZ Resident Employees and Employee Vehicles......................................

3-16 Table 3-6. BW D External Traffic..............................................................................................................

3-21 Table 3-7. Sum m ary of Population Dem and...........................................................................................

3-23 Table 3-8. Sum m ary of Vehicle Dem and.................................................................................................

3-24 Table 5-1. Event Sequence for Evacuation Activities................................................................................

5-3 Table 5-2. Tim e Distribution for Notifying the Public...............................................................................

5-6 Table 5-3. Time Distribution for Employees to Prepare to Leave Work...................................................

5-7 Table 5-4. Time Distribution for Com m uters to Travel Home..................................................................

5-8 Table 5-5. Time Distribution for Population to Prepare to Evacuate.......................................................

5-8 Table 5-6. Time Distribution for Population to Clear 6"-8" of Snow........................................................

5-9 Table 5-7. M apping Distributions to Events............................................................................................

5-11 Table 5-8. Description of the Distributions.............................................................................................

5-12 Table 5-9. Trip Generation Histograms for the EPZ Population for Un-staged Evacuation.................... 5-19 Table 5-10. Trip Generation Histograms for the EPZ Population for Staged Evacuation....................... 5-21 Table 6-1. Description of Evacuation Regions...........................................................................................

6-4 Table 6-2. Evacuation Scenario Definitions...............................................................................................

6-7 Table 6-3. Percent of Population Groups Evacuating for Various Scenarios............................................

6-8 Table 6-4. V ehicle Estim ates by Scenario..................................................................................................

6-9 Table 7-1. Time to Clear the Indicated Area of 90 Percent of the Affected Population...........................

7-9 Table 7-2. Time to Clear the Indicated Area of 100 Percent of the Affected Population....................... 7-11 Table 7-3. Time to Clear 90 Percent of the 2-Mile Area within the Indicated Region............................ 7-13 Table 7-4. Time to Clear 100 Percent of the 2-Mile Area within the Indicated Region.......................... 7-15 Table 7-5. Description of Evacuation Regions.........................................................................................

7-17 Table 8-1. Transit-Dependent Population Estim ates..............................................................................

8-13 Table 8-2. School, Pre-School, and Day Camp Population Demand Estimates.......................................

8-14 Table 8-3. School, Pre-School, and Day Camp Reception Centers..........................................................

8-16 Table 8-4. M edical Facility Transit Dem and............................................................................................

8-17 Table 8-5. Sum m ary of Transportation Resources..................................................................................

8-18 Table 8-6. Bus Route Descriptions..........................................................................................................

8-19 Table 8-7. School, Pre-School, and Day Camp Evacuation Time Estimates - Good Weather................. 8-21 Table 8-8. School, Pre-School, and Day Camp Evacuation Time Estimates - Rain.................................

8-23 Table 8-9. School, Pre-School, and Day Camp Evacuation Time Estimates - Snow................................

8-25 Table 8-10. Sum m ary of Transit-Dependent Bus Routes........................................................................

8-27 Table 8-11. Transit-Dependent Evacuation Time Estimates - Good Weather........................................

8-29 Table 8-12. Transit-Dependent Evacuation Time Estimates - Rain.........................................................

8-30 Table 8-13. Transit Dependent Evacuation Time Estimates - Snow.......................................................

8-31 Braidwood Generating Station viii KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 8-14. Medical Facility Evacuation Time Estimates - Good Weather.............................................

8-32 Table 8-15. Medical Facility Evacuation Time Estimates - Rain.............................................................

8-32 Table 8-16. Medical Facility Evacuation Time Estimates - Snow............................................................

8-33 Table 8-17. Homebound Special Needs Population Evacuation Time Estimates...................................

8-34 Table 12-i. Estimated Number of Telephone Calls Required for Confirmation of Evacuation.............. 12-2 Table A-1. Glossary of Traffic Engineering Term s.................................................................................

A-i Table C-i. Selected Measures of Effectiveness Output by DYNEV II........................................................

C-2 Table C-2. Input Requirem ents for the DYNEV II M odel...........................................................................

C-3 T a b le C -3. G lo ssa ry....................................................................................................................................

C -7 Table E-i. Schools w ithin the EPZ.......................................................................................................

E-2 Table E-2. Preschools and Day Cam ps w ithin the EPZ..............................................................................

E-4 Table E-3. M edical Facilities w ithin the EPZ..............................................................................................

E-4 Table E-4. Em ployers w ithin the EPZ...................................................................................................

E-5 Table E-5. Recreational Areas w ithin the EPZ.....................................................................................

E-6 Table E-6. Lodging Facilities w ithin the EPZ..........................................................................................

E-7 Table E-7. Correctional Facilities w ithin the EPZ...................................................................................

E-7 Table H-1. Percent of Sub-area Population Evacuating for Each Region (Regions RO2-R25).................. H-2 Table J-i. Characteristics of the Ten Highest Volume Signalized Intersections....................................

J-2 Table J-2. Sam ple Sim ulation M odel Input.........................................................................................

J-4 Table J-3. Selected Model Outputs for the Evacuation of the Entire EPZ (Region R03).......................

J-5 Table 1-4. Average Speed (mph) and Travel Time (min) for Major Evacuation Routes (Reg io n R0 3, Sce nario 1)............................................................................................................................

J-6 Table J-5. Simulation Model Outputs at Network Exit Links for Region R03, Scenario 1..................... J-7 Table K-i. Evacuation Roadway Network Characteristics......................................................................

K-48 Table K-2. Nodes in the Link-Node Analysis Network which are Controlled...................................

K-137 Table M-1. Evacuation Time Estimates for Trip Generation Sensitivity Study...................................

M-1 Table M-2. Evacuation Time Estimates for Shadow Sensitivity Study....................................................

M-2 Table M -3. ETE Variation w ith Population Change.................................................................................

M -4 Table N-i. ETE Review Criteria Checklist............................................................................................

N-i Braidwood Generating Station ix KLD Engineering. P.C.

Fvacuafinn Timp Fqfimatp Rpv. 0

EXECUTIVE

SUMMARY

This report describes the analyses undertaken and the results obtained by a study to develop Evacuation Time Estimates (ETE) for the Braidwood Generating Station (BWD) located in Grundy County, Illinois.

ETE are part of the required planning basis and provide Exelon and state and local governments with site-specific information needed for Protective Action decision-making.

In the performance of this effort, guidance is provided by documents published by Federal Governmental agencies. Most important of these are:

NUREG/CR-7002, SAND 2010-0061P, "Criteria for Development of Evacuation Time Estimate Studies," November 2011. (NRC, 2011a).

0 NUREG/CR-1745, "Analysis of Techniques for Estimating Evacuation Times for Emergency Planning Zones," November, 1980. (NRC, 1980a).

NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980. (NRC, 1980b) 0 NUREG/CR-6863, SAND2004-5900, "Development of Evacuation Time Estimate Studies for Nuclear Power Plants," January 2005. (NRC, 2005).

0 Title 10, Code of Federal Regulations, Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities, 2011. (NRC, 2011b).

Overview of Project Activities This project began in January, 2014 and extended over a period of 4 months. The major activities performed are briefly described in chronological sequence:

" Accessed U.S. Census Bureau data files for the year 2010.

Studied Geographical Information Systems (GIS) maps of the area in the vicinity of BWD, then conducted a detailed field survey of the highway network.

Synthesized this information to create an analysis network representing the highway system topology and capacities within the Emergency Planning Zone (EPZ), plus a Shadow Region covering the region between the EPZ boundary and approximately 15 miles radially from the plant.

" Analyzed the results of a telephone survey of residents within the EPZ to gather focused data needed for this ETE study that were not contained within the census database. The survey instrument was reviewed and modified by the licensee and offsite response organization (ORO) personnel prior to conducting the survey.

Data pertaining to employment, transients, and special facilities in each county were provided by Exelon and by state and county OROs.

The traffic demand and trip-generation rates of evacuating vehicles were estimated Braidwood Generating Station ES-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

from the gathered data. The trip generation rates reflected the estimated mobilization time (i.e., the time required by evacuees to prepare for the evacuation trip) computed using the results of the telephone survey of EPZ residents.

" The EPZ is subdivided into 16 Sub-areas. Following federal guidelines, these existing Sub-areas are grouped within circular areas or "keyhole" configurations (circles plus radial sectors) that define a total of 38 Evacuation Regions.

The time-varying external circumstances are represented as Evacuation Scenarios, each described in terms of the following factors: (1) Season (Summer, Winter); (2) Day of Week (Midweek, Weekend); (3) Time of Day (Midday, Evening); and (4) Weather (Good, Rain, Snow). One special event scenario - Refueling Outage at BWD - was considered.

One roadway impact scenario was considered wherein a single lane on 1-55 Northbound was closed.

Staged evacuation was considered for those regions wherein the 2 mile radius and sectors downwind to 5 miles were evacuated.

As per NUREG/CR-7002, the Planning Basis for the calculation of ETE is:

" A rapidly escalating accident at BWD that quickly assumes the status of General Emergency such that the Advisory to Evacuate is virtually coincident with the siren alert, and no early protective actions have been implemented.

" While an unlikely accident scenario, this planning basis will yield ETE, measured as the elapsed time from the Advisory to Evacuate until the stated percentage of the population exits the impacted Region, that represent "upper bound" estimates. This conservative Planning Basis is applicable for all initiating events.

If the emergency occurs while schools, preschools, and day camps are in session, the ETE study assumes that the children will be evacuated by bus directly to reception centers located outside the EPZ. Parents, relatives, and neighbors are advised to not pick up their children at schools, preschools, or camps prior to the arrival of the buses dispatched for that purpose.

The ETE for children at these facilities are calculated separately.

Evacuees who do not have access to a private vehicle will either ride-share with relatives, friends or neighbors, or be evacuated by buses provided as specified in the Illinois Plan for Radiological Accidents.

Those in special facilities will likewise be evacuated with public transit, as needed: bus, wheelchair bus, or ambulance, as required.

Separate ETE are calculated for the transit-dependent evacuees, for homebound special needs population, and for those evacuated from special facilities.

Computation of ETE A total of 532 ETE were computed for the evacuation of the general public. Each ETE quantifies the aggregate evacuation time estimated for the population within one of the 38 Evacuation Regions to evacuate from that Region, under the circumstances defined for one of the 14 Evacuation Scenarios (38 x 14 = 532).

Separate ETE are calculated for transit-dependent Braidwood Generating Station ES-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

evacuees, including children for applicable scenarios.

Except for Region R03, which is the evacuation of the entire EPZ, only a portion of the people within the EPZ would be advised to evacuate. That is, the Advisory to Evacuate applies only to those people occupying the specified impacted region. It is assumed that 100 percent of the people within the impacted region will evacuate in response to this Advisory.

The people occupying the remainder of the EPZ outside the impacted region may be advised to take shelter.

The computation of ETE assumes that 20% of the population within the EPZ but outside the impacted region, will elect to "voluntarily" evacuate. In addition, 20% of the population in the Shadow Region will also elect to evacuate. These voluntary evacuees could impede those who are evacuating from within the impacted region. The impedance that could be caused by voluntary evacuees is considered in the computation of ETE for the impacted region.

Staged evacuation is considered wherein those people within the 2-mile region evacuate immediately, while those beyond 2 miles, but within the EPZ, shelter-in-place. Once 90% of the 2-mile region is evacuated, those people beyond 2 miles begin to evacuate. As per federal guidance, 20% of people beyond 2 miles will evacuate (non-compliance) even though they are advised to shelter-in-place.

The computational procedure is outlined as follows:

A link-node representation of the highway network is coded.

Each link represents a unidirectional length of highway; each node usually represents an intersection or merge point. The capacity of each link is estimated based on the field survey observations and on established traffic engineering procedures.

" The evacuation trips are generated at locations called "zonal centroids" located within the EPZ and Shadow Region. The trip generation rates vary over time reflecting the mobilization process, and from one location (centroid) to another depending on population density and on whether a centroid is within, or outside, the impacted area.

The evacuation model computes the routing patterns for evacuating vehicles that are compliant with federal guidelines (outbound relative to the location of the plant), and then simulates the traffic flow movements over space and time. This simulation process estimates the rate that traffic flow exits the impacted region.

The ETE statistics provide the elapsed times for 90 percent and 100 percent, respectively, of the population within the impacted region, to evacuate from within the impacted region. These statistics are presented in tabular and graphical formats. The 9 0 th percentile ETE have been identified as the values that should be considered when making protective action decisions because the 100th percentile ETE are prolonged by those relatively few people who take longer to mobilize. This is referred to as the "evacuation tail" in Section 4.0 of NUREG/CR-7002.

Traffic Management This study references the comprehensive traffic management plan provided by the Illinois Emergency Management Agency (IEMA).

Braidwood Generating Station ES-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

The ETE simulations discussed in Section 7.3 indicate pronounced traffic congestion along Illinois State Route 113 (IL-113) westbound and IL-47 southbound within the EPZ.

This congestion is the result of the many vehicles evacuating from the densely populated communities of Carbon Hill, Coal City and Diamond, and the limited northbound evacuation routes leaving the EPZ. Additional traffic control points (TCPs) or access control points (ACPs) or modification to existing TCPs and ACPs does not alleviate this congestion. The existing traffic management plans are adequate. See Section 9 and Appendix G.

Selected Results A compilation of selected information is presented on the following pages in the form of figures and tables extracted from the body of the report; these are described below.

Figure 6-1 displays a map of the BWD EPZ showing the layout of the 16 Sub-areas that comprise, in aggregate, the EPZ.

" Table 3-1 presents the estimates of permanent resident population in each Sub-area based on the 2010 Census data.

Table 6-1 defines each of the 38 Evacuation Regions in terms of their respective groups of Sub-areas.

Table 6-2 defines the Evacuation Scenarios.

Tables 7-1 and 7-2 are compilations of ETE. These data are the times needed to clear the indicated regions of 90 and 100 percent of the population occupying these regions, respectively. These computed ETE include consideration of mobilization time and of estimated voluntary evacuations from other regions within the EPZ and from the Shadow Region.

Tables 7-3 and 7-4 present ETE for the 2-mile region for un-staged and staged evacuations for the 9 0 th and 1 0 0 th percentiles, respectively.

Table 8-7 presents ETE for the children at schools, preschools and camps in good weather.

" Table 8-11 presents ETE for the transit-dependent population in good weather.

Figure H-8 presents an example of an Evacuation Region (Region R08) to be evacuated under the circumstances defined in Table 6-1.

Maps of all regions are provided in Appendix H.

Braidwood Generating Station ES-4 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Conclusions

" General population ETE were computed for 532 unique cases - a combination of 38 unique Evacuation Regions and 14 unique Evacuation Scenarios. Table 7-1 and Table 7-2 document these ETE for the 90th and 1 0 0 th percentiles. These ETE range from 1:55 (hr:min) to 3:15 at the 90th percentile.

" Inspection of Table 7-2 indicates that the 100th percentile ETE for all Regions and for all Scenarios, with the exception of the special event, are slightly longer than mobilization time. This is due to the congestion along IL-113 westbound and IL-47 southbound; see Figure 7-3 through Figure 7-7.

" Inspection of Table 7-3 and Table 7-4 indicates that a staged evacuation protective action strategy provides no benefits to evacuees from within the 2-mile Region. See Section 7.6 for additional discussion.

Comparison of Scenarios 6 and 13 in Table 7-1 indicates that the Special Event - a refueling outage - has no impact on the 9 0 th or 1 0 0 th percentile ETE. See Section 7.5.

" Comparison of Scenarios 1 and 14 in Table 7-1 and Table 7-2 indicates that events such as adverse weather or traffic accidents which cause a roadway closure - i.e., 1-55 northbound (see Section 2.2, item 7 for additional information) - increase the 9 0 th and 100th percentile ETE by at most 40 minutes and 30 minutes, respectively - a significant change. See Section 7.5 for additional discussion.

All traffic congestion (LOS F) within the EPZ clears by 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 50 minutes after the Advisory to Evacuate.

See Section 7.3 and Figures 7-3 through 7-7.

" Separate ETE were computed for schools, preschools, day camps, medical facilities, transit-dependent persons, and homebound special needs persons. The average single-wave ETE for this population is at most 40 minutes longer than the general population ETE at the 9 0 th percentile. See Section 8.

" Table 8-5 indicates that there are enough buses, wheelchair buses, and ambulances available to evacuate the transit-dependent population within the EPZ in a single wave.

" The general population ETE at the 1 0 0 th percentile is sensitive to changes in the base trip generation time of 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 30 minutes. The 100th percentile ETE is dictated by the time it takes to clear the traffic congestion along IL-113 and IL-47, up to 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 55 minutes. Beyond this time, the 100th percentile ETE is dictated by trip generation time. The longer it takes people to mobilize, the longer it takes for the last vehicle to cross the EPZ boundary. See Table M-1.

" The general population ETE is not significantly affected by the voluntary evacuation of vehicles in the Shadow Region. See Table M-2.

A population increase of 27% or greater results in 9 0 th percentile ETE changes which meet the federal criteria for updating ETE between decennial Censuses. See Section M.3.

Braidwood Generating Station ES-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure 6-1. BWD EPZ Sub-areas Braidwood Generating Station Evacuation Time Estimate ES-6 KLD Engineering, P.C.

Rev. 0

Table 3-1. EPZ Permanent Resident Population Su-ae 200 Pouato 201 Popuatio 1

6,054 6,948 2

399 387 3

751 724 4

1,765 1,643 5

5,651 5,806 6

795 1,045 7

3,984 4,427 8

2,535 2,454 9

1,432 1,353 10 4,892 6,467 11 242 330 12 1,377 1,487 13 3,741 3,732 14 940 997 15 1,543 1,586 16 392 376 EPZ Population Growth:

8.96%

Braidwood Generating Station Evacuation Time Estimate ES-7 KLD Engineering, P.C.

Rev. 0

Table 6-1. Description of Evacuation Regions Region Wind Direction Toward:

R16 N

R17 NNE, NE, ENE R18 E, ESE, SE R19 SSE R20 S

R21 SSW R22 SW, WSW R23 W

R24 WNW, NW R25 NNW Sub-area(s) Shelter Sub-area

-o

-in-Place Braidwood Generating Station Evacuation Time Estimate ES-8 KLD Engineering, P.C.

Rev. 0

Sub-area Region Description 1213 4 516[7 [8ll01 1 21131141 15 1 16 Stge Evcato l

Raiu Evcats then Evcut Do n

idt ie Sub-area Region Wind Direction Toward:

R26 5-Mile Ring R27 NNW, N R28 NNE, NE, ENE R29 E

R30 ESE, SE R31 SSE R32 SSSW R33 SW, WSW R34 W

R35 WNW, NW R36 2 sector approach R37 2 sector approach 1234 5

7 8 9

1 11 1 12 13 1 14 15 16

____ I I

I I

I I I I I I I I I Sub-area(s) Shelter-in-Place I

I I

I I

I Braidwood Generating Station Evacuation Time Estimate ES-9 KLD Engineering, P.C.

Rev. 0

Table 6-2. Evacuation Scenario Definitions Scnai Seaon Day of Wee Tim ofDy Wahepca 1

Summer Midweek Midday Good None 2

Summer Midweek Midday Rain None 3

Summer Weekend Midday Good None 4

Summer Weekend Midday Rain None S

Summer

Midweek, Evening Good None Weekend 6

Winter Midweek Midday Good None 7

Winter Midweek Midday Rain None 8

Winter Midweek Midday Snow None 9

'Winter Weekend Midday Good None 10 Winter Weekend Midday Rain None 11 Winter Weekend Midday Snow None 12 Winter

Midweek, Evening Good None Weekend 13 Winter Midweek Midday Good Refueling Outage Single Lane 14 Summer Midweek Midday Good Closure on 1-55 Northbound I Winter assumes that school is in session (also applies to spring and autumn). Summer assumes that school is not in session.

Braidwood Generating Station Evacuation Time Estimate ES-10 KLD Engineering, P.C.

Rev. 0

Table 7-1. Time to Clear the Indicated Area of 90 Percent of the Affected Population Summer Summer Summer Winter Winter Winter Winter Summer Midweek M

idekWeedMidweek eekend Midweek Midweek Weekend Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Refueling Roadway Weather Weather Weather Weather I

S Weather Weather Outage Impact Entire 2-Mile Region, 5-Mile Region, and EPZ RO 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R02 2:10 2:20 2:10 2:20 2:15 2:15 2:20 2:35 2:10 2:15 2:30 2:15 2:15 2:50 R03 2:20 2:30 2:15 2:25 2:20 2:20 2:30 2:50 2:15 2:25 2:40 2:20 2:20 2:55 2-Mile Region and Keyhole to 5 Miles R04 2:10 2:15 2:05 2:15 2:10 2:10 2:15 2:30 2:05 2:15 2:25 2:10 2:10 2:45 ROS 2:00 2:05 2:00 2:05 1:55 2:05 2:05 2:20 2:00 2:00 2:20 1:55 2:05 2:30 R06 2:00 2:05 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R07 2:00 2:00 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R08 2:00 2:05 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R09 2:00 2:00 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 RIO 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:25 Rll 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R12 2:15 2:20 2:10 2:15 2:20 2:15 2:20 2:35 2:10 2:15 2:30 2:20 2:15 2:40 Site Specific Regions R13 2:00 2:00 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R14 2:10 2:15 2:05 2:10 2:05 2:10 2:15 2:30 2:05 2:10 2:25 2:10 2:10 2:30 RIS 2:00 2:05 2:05 2:05 1:55 2:05 2:05 2:20 2:00 2:05 2:20 1:55 2:05 2:30 5-Mile Region and Keyhole to EPZ Boundary R16 2:10 2:20 2:10 2:20 2:10 2:10 2:15 2:30 2:10 2:15 2:30 2:10 2:10 2:45 R17 2:10 2:20 2:10 2:20 2:10 2:10 2:15 2:35 2:05 2:15 2:30 2:10 2:10 2:45 R18 2:10 2:15 2:10 2:15 2:10 2:15 2:15 2:35 2:10 2:15 2:25 2:10 2:15 2:45 R19 2:10 2:15 2:10 2:15 2:15 2:15 2:20 2:35 2:10 2:15 2:30 2:15 2:15 2:50 R20 2:15 2:20 2:10 2:15 2:15 2:15 2:20 2:35 2:10 2:15 2:30 2:15 2:15 2:50 R21 2:30 2:40 2:25 2:35 2:40 2:35 2:50 3:15 2:30 2:40 3:05 2:40 2:35 3:10 R22 2:25 2:30 2:20 2:25 2:35 2:30 2:35 3:00 2:25 2:30 2:50 2:35 2:30 3:05 R23 2:25 2:30 2:20 2:25 2:30 2:30 2:35 3:00 2:20 2:30 2:45 2:30 2:30 3:05 R24 2:20 2:30 2:15 2:20 2:25 2:25 2:30 2:55 2:20 2:25 2:45 2:30 2:25 3:00 R25 2:15 2:25 2:15 2:25 2:20 2:20 2:25 2:45 2:15 2:20 2:35 2:20 2:20 2:55 Braidwood Generating Station Evacuation Time Estimate ES-11 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Midweek Midweek Weekend Midweek Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Refueling Roadway Weather Weather Weather Weather I

Weather R

S Weather Outage Impact Staged Evacuation Mile Region and Keyhole to 5 Miles R26 2:20 2:20 2:15 2:20 2:25 2:20 2:20 2:40 2:20 2:20 2:35 2:25 2:20 3:00 R27 2:15 2:20 2:15 2:15 2:20 2:20 2:20 2:35 2:15 2:15 2:30 2:20 2:20 2:50 R28 2:10 2:10 2:05 2:10 2:05 2:10 2:10 2:25 2:05 2:10 2:20 2:05 2:10 2:30 R29 2:05 2:05 2:00 2:05 2:05 2:05 2:10 2:20 2:05 2:05 2:20 2:05 2:05 2:15 R30 2:10 2:10 2:05 2:05 2:10 2:10 2:10 2:25 2:10 2:10 2:20 2:10 2:10 2:15 R31 2:05 2:10 2:05 2:05 2:05 2:10 2:10 2:25 2:05 2:10 2:20 2:05 2:10 2:20 R32 2:10 2:10 2:05 2:10 2:10 2:10 2:10 2:25 2:10 2:10 2:25 2:10 2:10 2:20 R33 2:10 2:10 2:05 2:10 2:10 2:10 2:10 2:25 2:10 2:10 2:20 2:10 2:10 2:25 R34 2:05 2:10 2:05 2:05 2:05 2:05 2:10 2:20 2:05 2:05 2:15 2:05 2:05 2:20 R35 2:15 2:20 2:15 2:15 2:20 2:20 2:20 2:35 2:15 2:20 2:35 2:25 2:20 2:45 Staged Evacuation - Site Specific Regions R36 2:10 2:10 2:05 2:05 2:05 2:10 2:10 2:25 2:05 2:10 2:20 2:10 2:10 2:20 R37 2:15 2:20 2:15 2:15 2:20 2:15 2:20 2:35 2:15 2:15 2:30 2:20 2:15 2:35 R38 2:05 2:10 2:05 2:10 2:05 2:10 2:10 2:20 2:05 2:05 2:20 2:05 2:10 2:35 I

Braidwood Generating Station ES-12 Evacuation Time Estimate KLD Engineering, P.C.

Rev. 0

Table 7-2. Time to Clear the Indicated Area of 100 Percent of the Affected Population Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Midweek Midweek Weekend Midweek Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Go Goi Good Rai Good Refueling Roadway Weather Weather Weather Weather Weather Weather Outage Impact Entire 2-Mile Region, S-Mile Region, and EPZ R01 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R02 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:50 R03 3:55 4:20 3:55 4:20 3:50 4:00 4:25 5:00 3:50 4:20 4:55 3:50 4:00 4:25 2-Mile Region and Keyhole to 5 Miles R04 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 ROS 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R06 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R07 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R08 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R09 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 RiO 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R11 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R12 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 Site Specific Regions R13 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R14 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 RIS 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 5-Mile Region and Keyhole to EPZ Boundary R16 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:45 R17 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:45 R18 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:40 R19 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:40 R20 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:40 R21 3:55 4:15 3:50 4:10 3:50 3:55 4:20 4:55 3:50 4:10 4:45 3:50 3:55 4:20 R22 3:55 4:20 3:50 4:15 3:50 3:55 4:20 5:00 3:50 4:15 4:50 3:50 3:55 4:25 R23 3:55 4:20 3:55 4:15 3:50 4:00 4:25 5:00 3:50 4:20 4:50 3:50 4:00 4:25 R24 3:50 4:10 3:45 4:10 3:45 3:50 4:15 4:55 3:45 4:10 4:45 3:45 3:50 4:15 R25 3:40 4:00 3:40 4:00 3:40 3:40 4:05 4:40 3:40 3:55 4:40 3:40 3:40 4:05 Braidwood Generating Station Evacuation Time Estimate ES-13 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Midweek Midweek Weekend Midweek Midweek Midw Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Refueling Roadway Weather Weather Weather Weather R

Weather I

Weather Outage Impact Staged Evacuation Mile Region and Keyhole to 5 Miles R26 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:50 R27 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R28 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R29 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R30 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R31 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R32 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R33 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R34 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R35 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:50 Staged Evacuation - Site Specific Regions R36 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R37 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R38 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 ES-14 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate ES-14 KLD Engineering, P.C.

Rev. 0

Table 7-3. Time to Clear 90 Percent of the 2-Mile Area within the Indicated Region Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Mi2-MiMidweek Weekend 5-Miee Midweek Midweek Weekend Weekend Scnro 12:

0 51 5

2 00 5

0 202:1512:002:6)

(7

()

9)

(002:1 11:5

[12 :0 2:20(14 Midday Midday Evening Midday Midday Evening Midday Miday Region Good Rain Good Rain Good Good Rain Snow Good Rain Snow Good Refueling Roadway Weat'her Weather IWeather Weather IWeather Weather Outage Impact Un-staged Evacuation Mile and 5-Mile Region R01 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R02 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Un-staged Evacuation Mile Ring and Keyhole to S-Miles1 R04 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R05 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R06 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R07 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R08 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R09 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R10 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R1l 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R12 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Un-staged Evacuation - Site Specific Regions R13 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R14 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R15 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Staged Evacuation Mile Region R26 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Staged Evacuation Mile Ring and Keyhole to 5 Miles R27 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R28 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R29 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R30 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R31 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R32 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R33 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R34 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R35 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Braidwood Generating Station Evacuation Time Estimate ES-15 KLD Engineering, P.C.

Rev. 0

ES-1 KLDEngineering, P.C.

Braidwood Generating Station Evacuation Time Estimate

Table 7-4. Time to Clear 100 Percent of the 2-Mile Area within the Indicated Region Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend Midweek Midweek Weekend Midweek Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Good Good Good Refueling Roadway eather Weather Weather Weather Weather Weather Outage Impact Un-staged Evacuation Mile and 5-Mile Region RO1 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R02 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Un-staged Evacuation Mile Ring and Keyhole to 5-Miles R04 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R05 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R06 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R07 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 ROB 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R09 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 RIO 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Rll 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R12 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Un-staged Evacuation - Site Specific Regions R13 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R14 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R15 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Staged Evacuation Mile Region R26 3:35 3:35 3:30 3:30 3:30 3:35 3:35 1

4:35 3:30 3:30 4:30 3:30 3:35 3:35 Staged Evacuation Mile Ring and Keyhole to 5 Miles R27 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R28 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R29 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R30 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R31 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R32 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R33 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R34 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R35 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Braidwood Generating Station Evacuation Time Estimate ES-17 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Midweek Weekend Weekend Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Good Rain Good Good Rain Snow Good Rain Snow Good Refueling Roadway Weather Rain Weather Weather Weather Weather Weather Outage Impact Staged Evacuation - Site Specific Regions R36 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R37 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R38 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 ES-18 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate ES-18 KLD Engineering, P.C.

Rev. 0

Table 8-7. School and Preschool Evacuation Time Estimates - Good Weather Y COUNTY Braceville Elementary School 90 15 13.4 53.7 15 Coal City Elementary School 90 15 20.5 11.3 109 Coal City High School 90 15 19.5 11.0 106 Coal City Intermediate School 90 15 20.5 11.1 111 Coal City Middle School 90 15 19.8 11.3 105 Gardner Elementary School 90 15 10.1 55.0 11 Gardner/South Wilmington High School 90 15 9.8 55.0 11 M.V.K. Elementary School 90 15 10.9 54.8 12 M.V.K. Middle School 90 15 10.8 54.8 12 South Wilmington Grade School 90 15 12.3 55.0 13 White Oak Elementary 90 15 Located Outside EPZ 2 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 24 24 24 24 24 24 24 24 24 24 40.2 [

44 KANKAKEE COUNTY Reddick Grade School 90 15 J 0.4 47.6 1

1 31.7[

35 SWILL COUNTY Bruning Elementary School 90 15 6.9 46.2 9

L.J. Stevens Intermediate School 90 15 5.2 42.5 7

Reed-Custer High School 90 15 8.7 53.7 10 Reed-Custer Intermediate School 90 15 9.2 38.5 14 Reed-Custer Middle School 90 15 8.9 53.7 10 Reed-Custer Primary School 90 15 7.2 55.0 8

St. Rose School 90 15 4.8 42.5 7

Trinity Services Island City 90 15 10.0 42.3 14 Wilmington High School 90 15 5.7 42.5 8

Wilmington Middle School 90 15 4.8 42.5 7

School Maximum for EPZ:

School Average for EPZ:

17.5 19 17.5 19 10.4 11 10.4 11 10.4 11 13.5 15 17.5 19 13.5 15 17.5 19 17.5 19 School Maximum:

School Average:

2 Facility is located just outside the EPZ; however, the facility will evacuate as per county plans. ETE for this facility is not included in the average for the EPZ.

Braidwood Generating Station Evacuation Time Estimate ES-19 KLD Engineering, P.C.

Rev. 0

Dist Travel GRUNDY COUNTY Boy Scouts of America 90 15 23.1 54.2 26 22.7 25 Coal City Early Childhood Center 90 15 20.0 11.3 106 22.4 24 Kid's Korner 90 15 19.9 11.1 107 22.4 24 Rainbow Preschool 90 15 1.6 55.0 2

43.3 47 Step by Step Child Care Center -

90 15 21.4 15.3 84 3:1 22.4 24 Diamond I1.

I WILL COUNTY Discovery Schoolhouse 90 15 5.4 42.5 8

Godley Park District Child Care Center 90 15 11.2 44.7 15 Grace Lutheran Preschool 90 15 5.6 42.5 8

Shepherd's Flock Pre-School 90 15 9.9 43.0 14 Step by Step Child Care Center -

90 15 9.3 37.7 15 Braidwood I

I I

I Pre-School, Day Camp Maximum for EPZ:

Pre-School, Day Camp Average for EPZ:

17.5 19 10.4 11 17.5 19 10.4 11 10.4 11 Pre-School, Day Camp Maximum:

Pre-School, Day Camp Average:

Braidwood Generating Station Evacuation Time Estimate ES-20 KLD Engineering, P.C.

ES-20 KLD Engineering, P.C.

Rev. 0

Table 8-11. Transit-Dependent Evacuation Time Estimates - Good Weather Sub-area 1 1-2 120 1 14.2 1 50.5 17 1

30 13.5 15 5

10 47 30 Sub-area 4 1

120 8.9 28.9 18 30 Sub-area 5 1

120 7.8 41.8 11 30 Sub-area 7 1

120 14.3 14.5 59 30 Sub-area 8 1

120 6.9 16.8 25 30 Sub-area 10 1-2 120 18.6 18.5 60 30 Sub-area 13 1

120 9.5 49.4 12 30 Sub-area 15 1

120 8.6 54.3 10 30 Maximum ETE:

Average ETE:

20.0 22 5

10 41 30 11.2 12 5

10 31 30 20.0 22 5

10 53 30 20.0 22 5

10 39 30 20.0 22 5

10 63 30 24.0 26 5

10 47 30 24.0 26 5

10 45 30 Braidwood Generating Station Evacuation Time Estimate ES-21 KLD Engineering, P.C.

Rev. 0

Figure H-8. Region R08 Braidwood Generating Station Evacuation Time Estimate ES-22 KLD Engineering, P.C.

Rev. 0

1 INTRODUCTION This report describes the analyses undertaken and the results obtained by a study to develop Evacuation Time Estimates (ETE) for the Braidwood Generating Station (BWD), located in Will County, Illinois. ETE provide state and local governments with site-specific information needed for Protective Action decision-making.

In the performance of this effort, guidance is provided by documents published by Federal Governmental agencies. Most important of these are:

NUREG/CR-7002, SAND 2010-0061P, "Criteria for Development of Evacuation Time Estimate Studies," November 2011. (NRC, 2011a)

NUREG/CR-1745, "Analysis of Techniques for Estimating Evacuation Times for Emergency Planning Zones," November, 1980. (NRC, 1980a)

NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980. (NRC, 1980b)

NUREG/CR-6863, SAND2004-5900, "Development of Evacuation Time Estimate Studies for Nuclear Power Plants," January 2005. (NRC, 2005)

Title 10, Code of Federal Regulations, Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities, 2011. (NRC, 2011b)

The work effort reported herein was supported and guided by Exelon who contributed suggestions, critiques, and the local knowledge base required.

Table 1-1 presents a summary of stakeholders and interactions.

Table 1-1. Stakeholder Interaction Stkhle Naur of-Stkhle Interaction Provided data (telephone

survey, employees, transients, special facilities, transit resources, special Exelon event) needed for the study.

Coordinated information exchange with offsite response organizations. Reviewed draft report and provided comments.

Illinois Emergency Management Agency (IEMA)

Provided existing emergency plans, including traffic Grundy County and access control points and other information critical to the ETE study. Engaged in the ETE Kankakee County development and informed of the study results.

Will County Provided data for medical facility in the EPZ.

1.1 Overview of the ETE Process The following outline presents a brief description of the work effort in chronological sequence:

Braidwood Generating Station 1-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

1. Information Gathering:
a. Defined the scope of work in discussions with representatives from Exelon.
b. Conducted bi-weekly conference calls with Exelon to identify issues to be addressed and resources available.
c.

Conducted a detailed field survey of the highway system and of area traffic conditions within the Emergency Planning Zone (EPZ) and Shadow Region.

d. Obtained demographic data from the 2010 Census and from Exelon.
e. Obtained results of a random sample telephone survey of EPZ residents from Exelon.
f.

Obtained data from Exelon and local offsite response organizations (OROs) to identify and describe schools, special facilities, major employers, transient attractions, transportation providers, and other important information.

2. Estimated distributions of Trip Generation times representing the time required by various population groups (permanent residents, employees, and transients) to prepare (mobilize) for the evacuation trip.

These estimates are primarily based upon the random sample telephone survey.

3. Defined Evacuation Scenarios. These scenarios reflect the variation in demand, in trip generation distribution and in highway capacities, associated with different seasons, day of week, time of day and weather conditions.
4. Reviewed the existing traffic management plan to be implemented by local and state police in the event of an incident at the plant. Traffic and access control are applied at specified Traffic Control Points (TCP) and Access Control Points (ACP) located within the study area.
5.

Utilized the 16 existing Sub-areas which generally follow township boundaries and major roadways or rivers to define Evacuation Regions. "Regions" are groups of contiguous Sub-areas for which ETE are calculated. The configurations of these Regions reflect wind direction and the radial extent of the impacted area. Each Region, other than those that approximate circular areas, approximates a "key-hole section" within the EPZ as recommended by NUREG/CR-7002.

6. Estimated demand for transit services for persons at special facilities and for transit-dependent persons at home.

Braidwood Generating Station 1-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

7. Prepared the input streams for the DYNEV II system.
a. Estimated the evacuation traffic demand, based on the available information derived from Census data, and from data provided by county and state agencies, Exelon and from the telephone survey.
b. Applied the procedures specified in the 2010 Highway Capacity Manual to the data acquired during the field survey, to estimate the capacity of all highway segments comprising the evacuation routes (TRB, 2010).
c.

Developed the link-node representation of the evacuation network, which is used as the basis for the computer analysis that calculates the ETE.

d. Calculated the evacuating traffic demand for each Region and for each Scenario.
e. Specified selected candidate destinations for each "origin" (location of each "source" where evacuation trips are generated over the mobilization time) to support evacuation travel consistent with outbound movement relative to the location of the BWD.
8. Executed the DYNEV II model to determine optimal evacuation routing and compute ETE for all residents, transients and employees ("general population") with access to private vehicles. Generated a complete set of ETE for all specified Regions and Scenarios.
9. Documented ETE in formats in accordance with NUREG/CR-7002.
10. Calculated the ETE for all transit activities including those for special facilities (schools, pre-schools, day camps, and medical facilities), for the transit-dependent population and for homebound special needs population.

1.2 The Braidwood Generating Station Location The BWD site is located in Will County, Illinois, approximately 21 miles south-southwest of Joliet, Illinois and 54 miles southwest of Chicago, Illinois. The EPZ includes part of Grundy, Kankakee, and Will Counties in Illinois. Figure 1-1 shows the location of the BWD site relative to Joliet and Chicago, as well as the major population centers and roadways in the area.

Braidwood Generating Station 1-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure 1-1. BWD Location Braidwood Generating Station Evacuation Time Estimate 1-4 KLD Engineering, P.C.

Rev. 0

1.3 Preliminary Activities These activities are described below.

Field Surveys of the Highway Network KILD personnel drove the entire highway system within the EPZ and the Shadow Region which consists of the area between the EPZ boundary and approximately 15 miles radially from the plant. The characteristics of each section of highway were recorded. These characteristics are shown in Table 1-2:

Table 1-2. Highway Characteristics Number of lanes 0

Posted speed Lane width 0

Actual free speed Shoulder type & width 0

Abutting land use Interchange geometries 0

Control devices Lane channelization & queuing 0

Intersection configuration (including capacity (including turn bays/lanes) roundabouts where applicable)

Geometrics: curves, grades (>4%)

Traffic signal type Unusual characteristics: Narrow bridges, sharp curves, poor pavement, flood warning signs, inadequate delineations, toll booths, etc.

Video and audio recording equipment were used to capture a permanent record of the highway infrastructure. No attempt was made to meticulously measure such attributes as lane width and shoulder width; estimates of these measures based on visual observation and recorded images were considered appropriate for the purpose of estimating the capacity of highway sections. For example, Exhibit 15-7 in the HCM indicates that a reduction in lane width from 12 feet (the "base" value) to 10 feet can reduce free flow speed (FFS) by 1.1 mph - not a material difference - for two-lane highways. Exhibit 15-30 in the HCM shows little sensitivity for the estimates of Service Volumes at Level of Service (LOS) E (near capacity), with respect to FFS, for two-lane highways.

The data from the audio and video recordings were used to create detailed geographical information systems (GIS) shapefiles and databases of the roadway characteristics and of the traffic control devices observed during the road survey; this information was referenced while preparing the input stream for the DYNEV II System.

As documented on page 15-5 of the HCM 2010, the capacity of a two-lane highway is 1,700 passenger cars per hour in one direction. For freeway sections, a value of 2,250 vehicles per hour per lane is assigned, as per Exhibit 11-17 of the HCM 2010. The road survey has identified several segments which are characterized by adverse geometrics on two-lane highways which are reflected in reduced values for both capacity and speed. These estimates are consistent with the service volumes for LOS E presented in HCM Exhibit 15-30.

These links may be Braidwood Generating Station 1-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

identified by reviewing Appendix K. Link capacity is an input to DYNEV II which computes the ETE. Further discussion of roadway capacity is provided in Section 4 of this report.

Traffic signals are either pre-timed (signal timings are fixed over time and do not change with the traffic volume on competing approaches), or are actuated (signal timings vary over time based on the changing traffic volumes on competing approaches). Actuated signals require detectors to provide the traffic data used by the signal controller to adjust the signal timings.

These detectors are typically magnetic loops in the roadway, or video cameras mounted on the signal masts and pointed toward the intersection approaches. If detectors were observed on the approaches to a signalized intersection during the road survey, detailed signal timings were not collected as the timings vary with traffic volume. TCPs at locations which have control devices are represented as actuated signals in the DYNEV II system.

If no detectors were observed, the signal control at the intersection was considered pre-timed, and detailed signal timings were gathered for several signal cycles. These signal timings were input to the DYNEV II system used to compute ETE, as per NUREG/CR-7002 guidance.

Figure 1-2 presents the link-node analysis network that was constructed to model the evacuation roadway network in the EPZ and Shadow Region. The directional arrows on the links and the node numbers have been removed from Figure 1-2 to clarify the figure. The detailed figures provided in Appendix K depict the analysis network with directional arrows shown and node numbers provided. The observations made during the field survey were used to calibrate the analysis network.

Telephone Survey The results of a telephone survey conducted in 2011 were obtained to gather information needed for the evacuation study. Appendix F presents the survey instrument, the procedures used and tabulations of data compiled from the survey returns.

These data were utilized to develop estimates of vehicle occupancy to estimate the number of evacuating vehicles during an evacuation and to estimate elements of the mobilization process.

This database was also referenced to estimate the number of transit-dependent residents.

Computing the Evacuation Time Estimates The overall study procedure is outlined in Appendix D. Demographic data were obtained from several sources, as detailed later in this report. These data were analyzed and converted into vehicle demand data. The vehicle demand was loaded onto appropriate "source" links of the analysis network using GIS mapping software. The DYNEV II system was then used to compute ETE for all Regions and Scenarios.

Analytical Tools The DYNEV II System that was employed for this study is comprised of several integrated computer models. One of these is the DYNEV (DYnamic Network EVacuation) macroscopic simulation model, a new version of the IDYNEV model that was developed by KLD under contract with the Federal Emergency Management Agency (FEMA).

Braidwood Generating Station 1-6 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

i r**.**.*=iiwm.=

10 10 I

tt~ol Co ottot5)

Shertd.n I.

-*r

/

-I--

~.1

  • Mrsellles Grand Legend
  • BWD Node Link Sub-area

%. 2,5,10,15 Mile Rings Shadow Region 20 0),,

H..T Rome,, Mae HOmr 0

n0 Oak

-Glen "il Fora~

P-420 ftird kodlltttt TJ.Aellegtl 0

NZ 0 MiesMG,,,t

atoa, "i

30

  • ioj Ol m i Teltrhn F 0{Ot.tset ad b"*

Ore

/in l

re eI s g

6 N,

Crate Sub~j-

-al

- ~

~

W Zt8t~it~i~~~ti O

Mim U'

Figure 1-2. BWD Link-Node Analysis Network Braidwood Generating Station Evacuation Time Estimate 1-7 KLD Engineering, P.C.

Rev. 0

DYNEV II consists of four sub-models:

A macroscopic traffic simulation model (for details, see Appendix C).

A Trip Distribution (TD), model that assigns a set of candidate destination (D) nodes for each "origin" (0) located within the analysis network, where evacuation trips are "generated" over time. This establishes a set of O-D tables.

" A Dynamic Traffic Assignment (DTA), model which assigns trips to paths of travel (routes) which satisfy the O-D tables, over time. The TD and DTA models are integrated to form the DTRAD (Dynamic Traffic Assignment and Distribution) model, as described in Appendix B.

A Myopic Traffic Diversion model which diverts traffic to avoid intense, local congestion, if possible.

Another software product developed by KID, named UNITES (UNIfied Transportation Engineering System) was used to expedite data entry and to automate the production of output tables.

The dynamics of traffic flow over the network are graphically animated using the software product, EVAN (EVacuation ANimator), developed by KLD. EVAN is GIS based, and displays statistics such as LOS, vehicles discharged, average speed, and percent of vehicles evacuated, output by the DYNEV II System. The use of a GIS framework enables the user to zoom in on areas of congestion and query road name, town name and other geographical information.

The procedure for applying the DYNEV II System within the framework of developing ETE is outlined in Appendix D. Appendix A is a glossary of terms.

For the reader interested in an evaluation of the original model, I-DYNEV, the following references are suggested:

NUREG/CR-4873, PNL-6171, "Benchmark Study of the I-DYNEV Evacuation Time Estimate Computer Code," (NRC, 1988a).

NUREG/CR-4874, PNL-6172, "The Sensitivity of Evacuation Time Estimates to Changes in Input Parameters for the I-DYNEV Computer Code," (NRC, 1988b).

The evacuation analysis procedures are based upon the need to:

Route traffic along paths of travel that will expedite their travel from their respective points of origin to points outside the EPZ.

Restrict movement toward the plant to the extent practicable, and disperse traffic demand so as to avoid focusing demand on a limited number of highways.

Move traffic in directions that are generally outbound, relative to the location of the plant.

DYNEV II provides a detailed description of traffic operations on the evacuation network. This description enables the analyst to identify bottlenecks and to develop countermeasures that are designed to represent the behavioral responses of evacuees.

The effects of these countermeasures may then be tested with the model.

Braidwood Generating Station 1-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

1.4 Comparison with Prior ETE Study Table 1-3 presents a comparison of this ETE study with the previous (2003) study. The ETE in this study are longer (up to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 40 minutes) than in the 2003 study. The major factors contributing to the differences between the ETE values obtained in this study and those of the previous study can be summarized as follows:

An increase in permanent resident population by approximately 9%.

A significant decrease (32%) in resident vehicle occupancy, which results in many more evacuating vehicles and longer ETE.

Consideration of shadow evacuation which can congest roadways outside the EPZ and delay the egress of EPZ evacuees, prolonging ETE.

" Trip generation rates are based on telephone survey results of EPZ residents. The trip generation times in this study are significantly longer than in the previous study.

Longer trip generation time could result in longer ETE (see Appendix M).

Table 1-3. ETE Study Comparisons

-Ip Preious ITE Su Iurren ETE Study Resident Population Basis Data obtained from 2000 Census data at Township and Block Group level.

Population = 36,527 ArcGIS Software using 2010 US Census blocks; area ratio method used.

Population = 39,762 The vehicle data was derived from the Resident demographic data and average number of 2.40 persons/household, 1.32 Population Vehicle persons per household and assumed to be evacuating vehicles/household Occupancy one vehicle per household. Vehicle yielding: 1.82 persons/vehicle occupancy 2.68 persons per household.

Employee estimates based on Data obtained by survey of major information provided about major Employee employers, Harris Infosource, and county employers in EPZ, US Census Population officials.

Longitudinal Employer-Household Employees = 2,601 Dynamics Employees = 1,669 Estimates based upon U.S. Census Based upon discussions with county data and the results of the emergency management officials, it was telephone survey. A total of 275 determined that the number of EPZ people who do not have access to a residents in the general population vehicle, requiring 10 buses to Transit-Dependent requiring transportation assistance is evacuate. An additional 433 Population minimal. Vehicle demand is calculated for homebound special needs persons the residential population based on require special transportation to occupancy factors that are applied to the evacuate (43 buses, 30 wheelchair total population, including those with no buses, and 20 ambulances - are available vehicles, required to evacuate this population).

Braidwood Generating Station Evacuation Time Estimate 1-9 KLD Engineering, P.C.

Rev. 0

Topic Prviu T Std Curn I

Std Uata oDtalned trom mapping soTtware, Braidwood Station Special Facilities Map (IPRA-Map B), county officials, and the 2003 AAA Tour Book For Illinois.

Transient Population Transient estimates based upon information provided by Exelon about transient attractions in EPZ.

Transients = 16,964 Includes Day Camp enrollment.

Transients = 31,769 Medical facility population based on Data obtained from county officials, information provided by Exelon and telephone surveys, and facility websites.

county agencies Medical Facility Population = 171 Current Census = 129 Special Facility Correctional Facility Population = 200 Buses Required = 3 Population Wheelchair Buses Required = 4 Buses/Vans Required = 19 Ambulances Required = 6 Ambulances/Wheelchair Vans Required = 22 Kankakee Minimum Security Unit closed since previous ETE study.

Data obtained from county officials, telephone surveys, and facility websites.

School population based on School enrollment = 6,666 information provided by Exelon School Population Daycare, Nursery, and Preschool School enrollment = 7,197 enrollment = 275 Pre-School enrollment = 844 Day Camp enrollment = 1,000 Voluntary evacuation from Not Considered since based on the 20 percent of the population within within EPZ in areas NUREG-0654 Appendix 4 values, there will the EPZ, but not within the outside region to be a minor effect to network.

Evacuation Region (see Figure 2-1) be evacuated Shadow 20% of people outside of the EPZ Evacuation Not considered.

within the Shadow Region (see Figure 7-2)

Network Size 187 links; 148 nodes 2,215 links; 1,569 nodes Evacuation routes from public brochure, Field surveys conducted in January 2014. Roads and intersections were Roadway highway and local roadway maps verified videoad.

Geometric Data by field road survey data collection in Road apcites o

2003.Road capacities based on 2010 2003.

HCM.

Direct evacuation to designated Reception Direct evacuation to designated Center.

Reception Center.

50 percent of transit-dependent Ridesharing Not Considered.

persons will evacuate with a I

I_ neighbor or friend.

Braidwood Generating Station Evacuation Time Estimate 1-10 KLD Engineering, P.C.

Rev. 0

I-TIc Peo llE S

tud'Culen E"'

Study Response curves were discussed with state and county officials and reflect the same methodology employed in the Trip Generation for Evacuation previous study.

Residents leave between 35 and 155 minutes.

Employees and transients leave between 15 and 65 minutes.

Based on residential telephone survey of specific pre-trip mobilization activities:

Residents with commuters returning leave between 30 and 210 minutes.

Residents without commuters returning leave between 15 and 150 minutes.

Employees and transients leave between 15 and 105 minutes.

All times measured from the Advisory to Evacuate.

Fair or Adverse. The capacity and free Good, Rain, or Snow. The capacity flow speed of all links in the network are and free flow speed of all links in reduced by 20% in adverse conditions in the network are reduced by 10% in the summer and 30% in winter, the event of rain and 20% for snow.

Modeling NetVac 2 DYNEV II System -Version 4.0.19.0 Special Events Not considered.

Refueling Outage - 1,000 additional employees 38 Regions (central sector wind 8 combinations for 28 evacuation zones direction and each adjacent sector producing 224 cases.

technique used) and 14 Scenarios producing 532 unique cases.

Evacuation Time ETE reported for 1 0 0 th percentile for each ETE reported for 9 0 th and 1 0 0 th Estimates Evacuation Section. Results presented by percentile population. Results Reporting Scenario.

presented by Region and Scenario.

Evacuation Time Winter, Midweek, Midday, Estimates for the Winter, Daytime, Fair Weather: 3:10 Good Weather: 4:00 th Summer, Midweek/Weekend, entire EPZ, 100th Summer, Nighttime, Fair Weather: 2:10 Evening percentile Evening Good Weather: 3:50 Braidwood Generating Station Evacuation Time Estimate 1-11 KLD Engineering, P.C.

Rev. 0

2 STUDY ESTIMATES AND ASSUMPTIONS This section presents the estimates and assumptions utilized in the development of the evacuation time estimates.

2.1 Data Estimates

1. Population estimates are based upon Census 2010 data.
2. Estimates of employees who reside outside the EPZ and commute to work within the EPZ are based upon data provided by Exelon and on the US Census Longitudinal Employer-Household Dynamics tools (see Section 3.4). Internet searches of individual employers and aerial imagery were used to supplement data provided by Exelon.
3. Population estimates at special and transient facilities are based on data provided by Exelon and state and county agencies.
4. Roadway capacity estimates are based on field surveys and the application of the Highway Capacity Manual 2010.
5.

Population mobilization times are based on a statistical analysis of data acquired from a random sample telephone survey of EPZ residents (see Section 5 and Appendix F).

6. The relationship between resident population and evacuating vehicles is developed from the telephone survey. Average values of 2.40 persons per household (See Appendix F, Figure F-i) and 1.32 evacuating vehicles per household (Figure F-4) are used. The relationship between persons and vehicles for employees, transients, and the special event is as follows:
a.

Employees: one employee per vehicle.

b. Transients: varies from 2.00 to 2.44 persons per vehicle depending on the type of facility. See Section 3.3 for additional information.
c. Special Event: a refueling outage at BWD with a vehicle occupancy of one employee per vehicle.

Braidwood Generating Station 2-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

2.2 Study Methodological Assumptions

1.

ETE are presented for the evacuation of the 9 0 th and 1 0 0 th percentiles of population for each Region and for each Scenario. The percentile ETE is defined as the elapsed time from the Advisory to Evacuate issued to a specific Region of the EPZ, to the time that Region is clear of the indicated percentile of evacuees. A Region is defined as a group of Sub-areas that is issued an Advisory to Evacuate.

A scenario is a combination of circumstances, including time of day, day of week, season, and weather conditions.

2. The ETE are computed and presented in tabular format and graphically, in a format compliant with NUREG/CR-7002.
3. Evacuation movements (paths of travel) are generally outbound relative to the plant to the extent permitted by the highway network. All major evacuation routes are used in the analysis.
4. Regions are defined by the underlying "keyhole" or circular configurations as specified in Section 1.4 of NUREG/CR-7002. These Regions, as defined, display irregular boundaries reflecting the geography of the Sub-areas included within these underlying configurations.
5.

As indicated in Figure 2-2 of NUREG/CR-7002, 100% of people within the impacted "keyhole" evacuate. 20% of those people within the EPZ, not within the impacted keyhole, will voluntarily evacuate. 20% of those people within the Shadow Region will voluntarily evacuate. See Figure 2-1 for a graphical representation of these evacuation percentages. Sensitivity studies explore the effect on ETE of increasing the percentage of voluntary evacuees in the Shadow Region (see Appendix M).

6. A total of 14 "Scenarios" representing different temporal variations (season, time of day, day of week) and weather conditions are considered. These Scenarios are outlined in Table 2-1.
7. Scenario 14 considers the closure of Interstate-55 northbound from the intersection of W Kennedy Rd/E Reed Rd (Exit 233) to the intersection with Interstate-80 (Exit 250).
8. The models of the I-DYNEV System were recognized as state of the art by the Atomic Safety & Licensing Board (ASLB) in past hearings (NRC, 1988a).

The models have continuously been refined and extended since those hearings and were independently validated by a consultant retained by the NRC. The new DYNEV II model incorporates the latest technology in traffic simulation and in dynamic traffic assignment. The DYNEV II System is used to compute ETE in this study.

Braidwood Generating Station 2-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 2-1. Evacuation Scenario Definitions S

D Sumek MD Week Time o Day W

r Nnei 1

Summer Midweek Midday Good None 2

Summer Midweek Midday Rain None 3

Summer Weekend Midday Good None 4

Summer Weekend Midday Rain None 5Summer

Midweek, Evening Good None Summer Weekend 6

Winter Midweek Midday Good None 7

Winter Midweek Midday Rain None 8

Winter Midweek Midday Snow None 9

Winter Weekend Midday Good None 10 Winter Weekend Midday Rain None 11 Winter Weekend Midday Snow None 12 Winter

Midweek, Evening Good None Weekend 13 Winter Midweek Midday Good Refueling Outage Single Lane 14 Summer Midweek Midday Good Closure on 1-55 Northbound Braidwood Generating Station Evacuation Time Estimate 2-3 KLD Engineering, P.C.

Rev. 0

Figure 2-1. Voluntary Evacuation Methodology Braidwood Generating Station Evacuation Time Estimate 2-4 KLD Engineering, P.C.

Rev. 0

2.3 Study Assumptions

1.

The Planning Basis Assumption for the calculation of ETE is a rapidly escalating accident that requires evacuation, and includes the following:

a. Advisory to Evacuate is announced coincident with the siren notification.
b.

Mobilization of the general population will commence within 15 minutes after siren notification.

c.

ETE are measured relative to the Advisory to Evacuate.

2.

It is assumed that everyone within the group of Sub-areas forming a Region that is issued an Advisory to Evacuate will, in fact, respond and evacuate in general accord with the planned routes.

3.

52 percent of the households in the EPZ have at least 1 commuter (see Figure F-3); 40 percent of those households with commuters will await the return of a commuter before beginning their evacuation trip (see Figure F-5), based on the telephone survey results. Therefore 21 percent (52% x 40% = 21%) of EPZ households will await the return of a commuter, prior to beginning their evacuation trip.

4. The ETE will also include consideration of "through" (External-External) trips during the time that such traffic is permitted to enter the evacuated Region. "Normal" traffic flow is assumed to be present within the EPZ at the start of the emergency.
5. Access Control Points (ACP) will be staffed within approximately 120 minutes following the siren notifications, to divert traffic attempting to enter the EPZ. Earlier activation of ACP locations could delay returning commuters. It is assumed that no through traffic will enter the EPZ after this 120 minute time period.
6. Traffic Control Points (TCP) within the EPZ will be staffed over time, beginning at the Advisory to Evacuate.

Their number and location will depend on the Region to be evacuated and resources available. The objectives of these TCP are:

a.

Facilitate the movements of all (mostly evacuating) vehicles at the location.

b. Discourage inadvertent vehicle movements towards the plant.
c.

Provide assurance and guidance to any traveler who is unsure of the appropriate actions or routing.

d. Act as local surveillance and communications center.
e. Provide information to the emergency operations center (EOC) as needed, based on direct observation or on information provided by travelers.

In calculating ETE, it is assumed that evacuees will drive safely, travel in directions identified in the plans, and obey all control devices and traffic guides.

7. Buses will be used to transport those without access to private vehicles:
a.

If schools, preschools and day camps are in session, transport (buses) will evacuate children directly to the designated reception centers.

b. Buses, wheelchair buses, and ambulances will evacuate patients at medical facilities within the EPZ, as needed.

Braidwood Generating Station 2-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

c. Transit-dependent general population will be evacuated to Reception Communities.
d. School children, if school is in session, are given priority in assigning transit vehicles.
e. Bus mobilization time is considered in ETE calculations.
f. Analysis of the number of required round-trips ("waves") of evacuating transit vehicles is presented.
8. Provisions are made for evacuating the transit-dependent portion of the general population to reception centers by bus, based on the assumption that some of these people will ride-share with family, neighbors, and friends, thus reducing the demand for buses. We assume that the percentage of people who rideshare is 50 percent. This assumption is based upon reported experience for other emergencies, and on guidance in Section 2.2 of NUREG/CR-7002 (IES, 1981).
9. Two types of adverse weather scenarios are considered. Rain may occur for either winter or summer scenarios; snow occurs in winter scenarios only. It is assumed that the rain or snow begins earlier or at about the same time the evacuation advisory is issued.

No weather-related reduction in the number of transients who may be present in the EPZ is assumed. It is assumed that roads are passable and that the appropriate agencies are plowing the roads as they would normally when snowing.

Adverse weather scenarios affect roadway capacity and the free flow highway speeds.

The factors applied for the ETE study are based on recent research on the effects of weather on roadway operations; the factors are shown in Table 2-2 (Agarwal, 2005).

10. School buses used to transport students are assumed to transport 70 students per bus for elementary schools and preschools, and 50 students per bus for middle schools, high schools and day camps. Transit buses used to transport the transit-dependent general population are assumed to transport 30 people per bus. Buses evacuating patients from medical facilities can transport 30 ambulatory people per bus; 15 wheelchair bound persons per wheelchair bus; and 2 bedridden patients per ambulance.

Table 2-2. Model Adjustment for Adverse Weather Rain 90%

90%

No Effect Snow 80%

80%

Clear driveway before leaving home (See Figure F-9)

  • Adverse weather capacity and speed values are given as a percentage of good weather conditions. Roads are assumed to be passable.

Braidwood Generating Station 2-6 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

3 DEMAND ESTIMATION The estimates of demand, expressed in terms of people and vehicles, constitute a critical element in developing an evacuation plan. These estimates consist of three components:

1. An estimate of population within the EPZ, stratified into groups (resident, employee, transient).
2. An estimate, for each population group, of mean occupancy per evacuating vehicle. This estimate is used to determine the number of evacuating vehicles.
3. An estimate of potential double-counting of vehicles.

Appendix E presents much of the source material for the population estimates. Our primary source of population data, the 2010 Census, however, is not adequate for directly estimating some transient groups.

Throughout the year, vacationers and tourists enter the EPZ. These non-residents may dwell within the EPZ for a short period (e.g. a few days or one or two weeks), or may enter and leave within one day. Estimates of the size of these population components must be obtained, so that the associated number of evacuating vehicles can be ascertained.

The potential for double-counting people and vehicles must be addressed. For example:

A resident who works and shops within the EPZ could be counted as a resident, again as an employee and once again as a shopper.

A visitor who stays at a hotel and spends time at a park, then goes shopping could be counted three times.

Furthermore, the number of vehicles at a location depends on time of day.

For example, motel parking lots may be full at dawn and empty at noon. Similarly, parking lots at area parks, which are full at noon, may be almost empty at dawn. Estimating counts of vehicles by simply adding up the capacities of different types of parking facilities will tend to overestimate the number of transients and can lead to ETE that are too conservative.

Analysis of the population characteristics of the BWD EPZ indicates the need to identify three distinct groups:

Permanent residents - people who are year round residents of the EPZ.

Transients - people who reside outside of the EPZ who enter the area for a specific purpose (visit a park, camping) and then leave the area.

Employees - people who reside outside of the EPZ and commute to businesses within the EPZ on a daily basis.

Estimates of the population and number of evacuating vehicles for each of the population groups are presented for each Sub-area and by polar coordinate representation (population rose). The BWD EPZ is subdivided into 16 Sub-areas. The EPZ is shown in Figure 3-1.

Braidwood Generating Station 3-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

3.1 Permanent Residents The primary source for estimating permanent population is the latest U.S. Census data. The average household size (2.40 persons/household - See Figure F-i) and the number of evacuating vehicles per household (1.32 vehicles/household - See Figure F-4) were adapted from the telephone survey results.

Population estimates are based upon Census 2010 data. The estimates are created by cutting the census block polygons by the Sub-area and EPZ boundaries. A ratio of the original area of each census block and the updated area (after cutting) is multiplied by the total block population to estimate what the population is within the EPZ. This methodology assumes that the population is evenly distributed across a census block. Table 3-1 provides the permanent resident population within the EPZ by Sub-area based on this methodology.

The year 2010 permanent resident population is divided by the average household size and then multiplied by the average number of evacuating vehicles per household in order to estimate number of vehicles. Permanent resident population and vehicle estimates are presented in Table 3-2. Figure 3-2 and Figure 3-3 present the permanent resident population and permanent resident vehicle estimates by sector and distance from BWD. This "rose" was constructed using GIS software.

It can be argued that this estimate of permanent residents overstates, somewhat, the number of evacuating vehicles, especially during the summer. It is certainly reasonable to assert that some portion of the population would be on vacation during the summer and would travel elsewhere. A rough estimate of this reduction can be obtained as follows:

Assume 50 percent of all households vacation for a two-week period over the summer.

Assume these vacations, in aggregate, are uniformly dispersed over 10 weeks, i.e. 10 percent of the population is on vacation during each two-week interval.

Assume half of these vacationers leave the area.

On this basis, the permanent resident population would be reduced by 5 percent in the summer and by a lesser amount in the off-season. Given the uncertainty in this estimate, we elected to apply no reductions in permanent resident population for the summer scenarios to account for residents who may be out of the area.

3.1.1 Special Facilities One medical facility, Island City Rehab (formerly Embassy Care Clinic), is located within the EPZ (see Table E-3). The facility has permanent residents that are included in the Census; however, the medical facility is transit dependent (will not evacuate in personal vehicles) and is addressed in Section 8. As such, the medical facility residents are included in the EPZ resident population, but no evacuating vehicles are considered for these residents. The vehicles in Table 3-2 and Figure 3-3 have been adjusted accordingly.

Braidwood Generating Station 3-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure 3-1. BWD EPZ Braidwood Generating Station Evacuation Time Estimate 3-3 KLD Engineering, P.C.

Rev. 0

Table 3-1. EPZ Permanent Resident Population 1

6,054 6,948 2

399 387 3

751 724 4

1,765 1,643 5

5,651 5,806 6

795 1,045 7

3,984 4,427 8

2,535 2,454 9

1,432 1,353 10 4,892 6,467 11 242 330 12 1,377 1,487 13 3,741 3,732 14 940 997 15 1,543 1,586 16 392 376 EPZ Population Growth:

8.96%

Braidwood Generating Station Evacuation Time Estimate 3-4 KLD Engineering, P.C.

Rev. 0

Table 3-2. Permanent Resident Population and Vehicles by Sub-area 201 S.b-are 201 Poplaio Reidn Vehcle 1

6,948 3,825 2

387 212 3

724 399 4

1,643 907 5

5,806 3,184 6

1,045 578 7

4,427 2,439 8

2,454 1,355 9

1,353 748 10 6,467 3,558 11 330 187 12 1,487 820 13 3,732 2,061 14 997 553 15 1,586 874 16 376 210 Braidwood Generating Station Evacuation Time Estimate 3-5 KLD Engineering, P.C.

Rev. 0

NNW 4 0 N

I 2,8-64 1 NNE 0

7 0'-

WNW 191 W

i1.0 IW 1,0 ENE 1,909 46

-I E

=137 ESE 639--

0 SSW 95-g--j 10

.8 SSE 548 Resident Population Miles Subtotal by Ring Cumulative Total 0-1 697 697 1 - 2 3,882 4,579 2 -3 3,469 8,048 3 -4 4,561 12,609 4-5 6,175 18,784 5-6 6,372 25,156 6-7 5,531 30,687 7-8 2,495 33,182 8-9 1,304 34,486 9 - 10 1,103 35,589 10 - EPZ 4,173 39,762 Total:

39,762 10 Miles to EPZ Boundary N

1,061I 615 7

64 17 2

0 E

W Inset 0 - 2 Miles S

Figure 3-2. Permanent Resident Population by Sector Braidwood Generating Station Evacuation Time Estimate 3-6 KLD Engineering, P.C.

Rev. 0

NNW N

IT5 576 1 NNE 0.....

it --..---.-.----

0 -

WNW i-W 559 26 ENE

'I E

-I ESE F353 WSW 0

ssw 59 S

F-30-1 F607--

Resident Vehicles Miles Subtotal by Ring Cumulative Total 0-1 385 385 1-2 2,136 2,521 2-3 1,912 4,433 3 -4 2,509 6,942 4 -5 3,398 10,340 5-6 3,511 13,851 6-7 3,042 16,893 7-8 1,379 18,272 8-9 718 18,990 9-10 614 19,604 10 - EPZ 2,306 21,910 Total:

21,910

-,10 Miles to EPZ Boundary N

583 338 0

404 36 9

1 0

E W

Inset 0 - 2 Miles S

Figure 3-3. Permanent Resident Vehicles by Sector Braidwood Generating Station Evacuation Time Estimate 3-7 KLD Engineering, P.C.

Rev. 0

3.2 Shadow Population A portion of the population living outside the evacuation area extending to 15 miles radially from the BWD (in the Shadow Region) may elect to evacuate without having been instructed to do so. Based upon NUREG/CR-7002 guidance, it is assumed that 20 percent of the permanent resident population, based on U.S. Census Bureau data, in this Shadow Region will elect to evacuate.

Shadow population characteristics (household size, evacuating vehicles per household, mobilization time) are assumed to be the same as that for the EPZ permanent resident population. Table 3-3, Figure 3-4, and Figure 3-5 present estimates of the shadow population and vehicles, by sector.

There are jails and medical facilities in the southwest and northwest sectors of the Shadow Region. These facilities would shelter-in-place in the event of an incident at BWD. As such, the people residing in these facilities are included in the population of the Shadow Region; however, evacuating vehicles are not considered for these facilities.

Table 3-3. Shadow Population and Vehicles by Sector Seco Pouato EvcaigVhce N

20,057 11,030 NNE 2,700 1,483 NE 191 106 ENE 380 209 E

581 319 ESE 930 510 SE 841 463 SSE 1,255 690 S

204 116 SSW 143 79 SW 3,234 1,702 WSW 45 25 W

408 224 WNW 181 98 NW 13,982 7,577 NNW 2,620 1,442 Braidwood Generating Station Evacuation Time Estimate 3-8 KLD Engineering, P.C.

Rev. 0

N NNW 120,0571 NNE F2,620 F2,700 WNW 181 w

408 45 ENE 134 i3 E

142 186 1

41 ESE 930 SE EPZ Boundary to 11 Miles SSW

-L SSE

~s Shadow Population Miles Subtotal by Ring Cumulative Total EPZ - 11 2,101 2,101 11 - 12 3,896 5,997 12-13 9,245 15,242 13 - 14 16,381 31,623 14-15 16,129 47,752 Total:

47,752 Figure 3-4. Shadow Population by Sector Braidwood Generating Station Evacuation Time Estimate 3-9 KLD Engineering, P.C.

Rev. 0

N NNW 111,0301 NNE WNW 98 w

-224-1 wSw 25 ENE F209-74 E

77 102 31 36 242 ESE SE EPZ Boundary to 11 Miles SSW SSE s

F-690 Shadow Vehicles Miles Subtotal by Ring Cumulative Total EPZ - 11 1,157 1,157 11 - 12 2,147 3,304 12 - 13 5,078 8,382 13 - 14 8,949 17,331 14 - 15 8,742 26,073 Total:

26,073 Figure 3-5. Shadow Vehicles by Sector Braidwood Generating Station Evacuation Time Estimate 3-10 KLD Engineering, P.C.

Rev. 0

3.3 Transient Population Transient population groups are defined as those people (who are not permanent residents, nor commuting employees) who enter the EPZ for a specific purpose (visit a park, camping).

Transients may spend less than one day or stay overnight at a campground or lodging facility. Data for the transient facilities within the EPZ were provided by Exelon. The BWD EPZ has a number of facilities that attract transients, including:

Campgrounds - 4,420 transients; 1,814 vehicles; 2.44 people per vehicle 0

Golf Courses - 428 transients; 177 vehicles; 2.44 people per vehicle 0

Parks-10,322 transients; 4,237 vehicles; 2.44 people per vehicle (NOTE: Local parks are not included; visitors to these facilities are local residents and have already been counted as permanent residents in Section 3.1.)

Hunting / Fishing Camps - 320 transients; 132 vehicles; 2.44 people per vehicle 0 Tammen Treeberry Farm - 1,200 transients; 492 vehicles; 2.44 people per vehicle 0

Lodging - 274 transients; 137 vehicles; 2.00 people per vehicle The BWD is located approximately 10 miles south-southeast of the Dresden Generating Station (DRE). The BWD EPZ and DRE EPZ overlap considerably due to the close proximity of the plants to one another. Many of the facilities listed in Appendix E are located within both EPZs. The average household size obtained from telephone survey results for BWD (2.40) and DRE (2.48) are similar. These values were averaged (2.44) to estimate transient vehicle occupancy. It is assumed that families will travel to campgrounds, golf courses, parks, hunting/fishing areas, and other recreational facilities together in a single vehicle. It is further assumed that there are 2 people per vehicle at lodging facilities.

Appendix E, Table E-5 and Table E-6 summarize the transient data that was gathered for the recreational areas and lodging facilities within the EPZ.

In total, there are 16,964 transients evacuating in 6,989 vehicles, an average of 2.43 transients per vehicle. Table 3-4 presents transient population and transient vehicle estimates by Sub-area. Figure 3-6 and Figure 3-7 present these data by sector and distance from the plant.

Braidwood Generating Station 3-11 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 3-4. Summary of Transients and Transient Vehicles S.

T i

Vehicles 1

5,813 2,402 2

2,611 1,078 3

1,950 800 4

172 72 5

910 376 6

271 112 7

850 349 8

0 0

9 0

0 10 2,500 1,025 11 0

0 12 0

0 13 1,232 506 14 655 269 15 0

0 16 0

0 Braidwood Generating Station Evacuation Time Estimate 3-12 KLD Engineering, P.C.

Rev. 0

N NNW NNE 6821 3,639 0

7

~8 WNW E-lI Ww---0 wSW Transients ENE 0

0 0

0 E

0 0

0 0

F60 0

ESE 1,050, 0,

SE 10 Miles to EPZ Boundary N

0 32 0

90 0

0 0

0)0 E

]

0 SSW E655-S 3,271 Miles Subtotal by Ring Cumulative Total 0-1 0

0 1-2 232 232 2 - 3 2,581 2,813 3 -4 7,550 10,363 4 -5 2,714 13,077 5 - 6 2,005 15,082 6-7 226 15,308 7-8 68 15,376 8-9 366 15,742 9-10 164 15,906 10 - EPZ 1,058 16,964 Total:

16,964 W

Inset 0 - 2 Miles S

Figure 3-6. Transient Population by Sector Braidwood Generating Station Evacuation Time Estimate 3-13 KLD Engineering, P.C.

Rev. 0

N NNW

___9_T F-2191

-4 NNE 0

WNW L-i--1 w

F-0 WSWw---

I 0

SSW F269-0 S

lo-1 1,342 N

Transient Vehicles Miles Subtotal by Ring Cumulative Total 0-1 0

0 1-22 112 112 2-3 1,060 1,172 3 -4 3,096 4,268 4-5 1,115 5,383 5 - 6 823 6,206 6-7 96 6,302 7-8 34 6,336 8 -9 150 6,486 9-10 68 6,554 10 - EPZ 435 6,989 Total:

6,989 W

E Inset 0 - 2 Miles S

Figure 3-7. Transient Vehicles by Sector Braidwood Generating Station Evacuation Time Estimate 3-14 KLD Engineering, P.C.

Rev. 0

3.4 Employees Employees who work within the EPZ fall into two categories:

Those who live and work in the EPZ Those who live outside of the EPZ and commute to jobs within the EPZ.

Those of the first category are already counted as part of the permanent resident population. To avoid double counting, we focus only on those employees commuting from outside the EPZ who will evacuate along with the permanent resident population.

Maximum shift employment data were provided by Exelon for the major employers (generally speaking 50 or more employees in accordance with NUREG/CR-7002) in the EPZ. The IEMA requested that major employers listed in the county and state emergency plans be listed in this study. These employers - many of which have less than the 50 employees typical of a major employer - are listed in Table E-4 along with the major employers in the EPZ. Internet research and verification of cars in parking lots using aerial imagery confirmed these employers to be small businesses. Smaller employers typically hire local residents. As such, employees at these smaller employers are not considered because they are already included in the permanent resident population discussed in Section 3.1.

Data obtained from the US Census Longitudinal Employer-Household Dynamics OnTheMap Census analysis tool1 were used to estimate the number of employees commuting into the EPZ to avoid double counting. This tool allows the user to draw a cordon around any area in the US and a report of the number of employees commuting into and out of the cordoned area is produced. The tool was used to draw a cordon around the EPZ. The inflow/outflow report for the EPZ was then used to calculate the percent of employees that work within the EPZ but live outside. Similar to the transient population calculations discussed in Section 3.3 many employers are within both the BWD and DRE EPZs. A combined EPZ was used with the OnTheMap tool to generate a combined percentage. This value, 63.3%, was applied to the maximum shift employment to compute the number of people commuting into the EPZ to work at peak times.

In Table E-4, the Employees (Max Shift) column is multiplied by the percent of employees commuting into the EPZ (63.3%) factor to determine the number of employees who are not residents of the EPZ.

It is conservatively assumed for all major employers that there is 1 employee per vehicle as carpooling in the US is minimal.

Table 3-5 presents employees commuting into the EPZ and their vehicles by Sub-area. Figure 3-8 and Figure 3-9 present these data by sector.

1 http://onthemap.ces.census.govI Braidwood Generating Station 3-15 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 3-5. Summary of Non-EPZ Resident Employees and Employee Vehicles I.*.

Subra E

poes Em lyeVhce.

1 601 601 2

0 0

3 0

0 4

560 560 5

256 256 6

0 0

7 83 83 8

0 0

9 0

0 10 0

0 11 0

0 12 32 32 13 102 102 14 35 35 15 0

0 16 0

0 Braidwood Generating Station Evacuation Time Estimate 3-16 KLD Engineering, P.C.

Rev. 0

N NNW F6431 560 0

NNE 0

WNW L-IZ-ENE L-I--

o0.

W 0

-j

)0 E

wsw ESE Fill 50 SSW E490I

-0 S

F-0---1 Employees Miles Subtotal by Ring Cumulative Total 0-1 490 490 1-2 0

490 2-3 111 601 3-4 0

601 4-5 83 684 5-6 119 803 6-7 64 867 7-8 108 975 8-9 64 1,039 9-10 70 1,109 10 -EPZ 560 1,669 Total:

1,669 10 Miles to EPZ Boundary N

0 0

0 0

0 0

0 0

E W

Inset 0 - 2 Miles S

Figure 3-8. Employee Population by Sector Braidwood Generating Station Evacuation Time Estimate 3-17 KLD Engineering, P.C.

Rev. 0

NNW F64 3 5 60 N

' 0 7

NNE 0

WNW LI6Z-W 0

ENE E

OI 0

E-1 ESE 11 wsw

~. 0 SSW 490--

0 S

FloI- -1 SE 10 Miles to EPZ Boundary N

0 0

0 0

0 0

o 0

E Employee Vehicles Miles Subtotal by Ring Cumulative Total 0-1 490 490 1-2 0

490 2-3 111 601 3-4 0

601 4-5 83 684 5-6 119 803 6-7 64 867 7-8 108 975 8-9 64 1,039 9-10 70 1,109 10 - EPZ 560 1,669 Total:

1,669 W

Inset 0 - 2 Miles S

Figure 3-9. Employee Vehicles by Sector Braidwood Generating Station Evacuation Time Estimate 3-18 KLD Engineering, P.C.

Rev. 0

3.5 Medical Facilities Data were provided by Exelon and the Will County Emergency Management Agency for the Island City Rehab Center. Table E-3 in Appendix E summarizes the data provided. Section 8 details the evacuation of the patients at this medical facility. The number and type of evacuating vehicles that need to be provided depend on the patients' state of health. It is estimated that buses can transport up to 30 people, wheelchair buses up to 15 people, and ambulances up to 2 people.

3.6 Total Demand in Addition to Permanent Population Vehicles will be traveling through the EPZ (external-external trips) at the time of an accident.

After the Advisory to Evacuate is announced, these through-travelers will also evacuate. These through vehicles are assumed to travel on the major routes traversing the EPZ 55, 1-80 and I-355. It is assumed that this traffic will continue to enter the EPZ during the first 120 minutes following the Advisory to Evacuate.

Average Annual Daily Traffic (AADT) data was obtained from Federal Highway Administration (HPMS, 2013) to estimate the number of vehicles per hour on the aforementioned routes. The AADT was multiplied by the K-Factor (TRB, 2010), which is the proportion of the AADT on a roadway segment or link during the design hour, resulting in the design hour volume (DHV).

The design hour is usually the 3 0 th highest hourly traffic volume of the year, measured in vehicles per hour (vph). The DHV is then multiplied by the D-Factor (TRB, 2010), which is the proportion of the DHV occurring in the peak direction of travel (also known as the directional split).

The resulting values are the directional design hourly volumes (DDHV), and are presented in Table 3-6, for each of the routes considered. The DDHV is then multiplied by 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> (access control points - ACP - are assumed to be activated at 120 minutes after the advisory to evacuate) to estimate the total number of external vehicles loaded on the analysis network. As indicated, there are 17,248 vehicles entering the EPZ as external-external trips prior to the activation of the ACP and the diversion of this traffic. This number is reduced by 60% for evening scenarios (Scenarios 5 and 12) as discussed in Section 6.

3.7 Special Event Two events were discussed with Exelon and county emergency management personnel: the Braidwood Lions Club Summerfest and a refueling outage at the plant.

The following information was provided for the Braidwood Lions Club Summerfest:

" The event is a multiday event held annually during a weekend in July.

" The event is located in the Braidwood City Park.

Peak attendance during the event is at the Sunday night fireworks show.

" The peak attendance is approximately 1,100 guests at any one time.

Ninety-five percent of attendees are local residents or from the immediate area.

Braidwood Generating Station 3-19 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Based on this data, only 55 people attending the event are non-EPZ residents (1,100 x 5% = 55).

A refueling outage, however, has an additional 1,000 non-EPZ employees at BWD. As such, a refueling outage results in the largest influx of transient population into the BWD EPZ. Using a vehicle occupancy of 1 employee per vehicle, there are an additional 1,000 employees and employee vehicles present at BWD during the special event.

There are no roadway closures or special traffic control treatments during an outage. There is no transit service for outage employees. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 45 minute mobilization time for employees (see Section 5) is sufficient time for employees to return to their car and begin their evacuation trip.

The special event (Scenario 13) is considered during the winter, midweek, midday with good weather.

Braidwood Generating Station Evacuation Time Estimate 3-20 KLD Engineering, P.C.

Rev. 0

Table 3-6. BWD External Traffic 8263 1574 1-80 Westbound 45,700 0.107 0.25 1,222 2,444 8069 69 1-80 Eastbound 45,700 0.107 0.50 2,445 4,890 8043 1036 1-55 Northbound 34,900 0.107 0.50 1,867 3,734 8003 3

1-55 Southbound 34,900 0.107 0.50 1,867 3,734 8268 268 1-355 Southbound 45,700 0.107 0.25 1,222 2,444 j

Braidwood Generating Station Evacuation Time Estimate 3-21 KLD Engineering, P.C.

Rev. 0

3.8 Summary of Demand A summary of population and vehicle demand is provided in Table 3-7 and Table 3-8, respectively. This summary includes all population groups described in this section. Additional population groups - transit-dependent, special facility, school, preschool and day camp population - are described in greater detail in Section 8. A total of 77,390 people and 53,423 vehicles are considered in this study.

Braidwood Generating Station Evacuation Time Estimate 3-22 KLD Engineering, P.C.

Rev. 0

Table 3-7. Summary of Population Demand 1

b,948 45

!5,813 bU1 U

1,155 U

[

U 15,lblZ 2

387 0

2,611 0

0 0

0 0

2,998 3

724 0

1,950 0

0 0

0 0

2,674 4

1,643 25 172 560 0

1,000 0

0 3,400 5

5,806 30 910 256 129 1,440 0

0 8,571 6

1,045 0

271 0

0 0

0 0

1,316 7

4,427 30 850 83 0

328 0

0 5,718 8

2,454 30 0

0 0

38 0

0 2,522 9

1,353 0

0 0

0 119 0

0 1,472 10 6,467 60 2,500 0

0 2,109 0

0 11,136 11 330 0

0 0

0 0

0 0

330 12 1,487 0

0 32 0

338 0

0 1,857 13 3,732 30 1,232 102 0

546 0

0 5,642 14 997 0

655 35 0

89 0

0 1,776 15 1,586 25 0

0 0

437 0

0 2,048 16 376 0

0 0

0 0

0 0

376 Shadow 00000842 9,550 0

0,392 3 Shadow population has been reduced to 20%. Refer to Figure 2-1 for additional information.

Braidwood Generating Station Evacuation Time Estimate 3-23 KLD Engineering, P.C.

Rev. 0

Table 3-8. Summary of Vehicle Demand Schol Prechol 1

3,825 4

2,402 601 0

72 0

0 6,904 2

212 0

1,078 0

0 0

0 0

1,290 3

399 0

800 0

0 0

0 0

1,199 4

907 2

72 560 0

40 0

0 1,581 5

3,184 2

376 256 20 62 0

0 3,900 6

578 0

112 0

0 0

0 0

690 7

2,439 2

349 83 0

10 0

0 2,883 8

1,355 2

0 0

0 2

0 0

1,359 9

748 0

0 0

0 4

0 0

752 10 3,558 4

1,025 0

0 86 0

0 4,673 11 187 0

0 0

0 0

0 0

187 12 820 0

0 32 0

12 0

0 864 13 2,061 2

506 102 0

18 0

0 2,689 14 553 0

269 35 0

4 0

0 861 15 874 2

0 0

0 18 0

0 894 16 210 0

0 0

0 0

0 0

210 Shadow 0

0 1

0 0

26 5,215 17,246 22,487

~~~0~ 020A0

~

~

4 Vehicles for medical facilities include wheelchair buses, ambulances and buses. Wheelchair buses and buses are represented as two passenger vehicles. Refer to Section 8 for additional information.

s Buses evacuating children from schools, preschools and day camps are represented as two passenger vehicles. Refer to Section 8 for additional information.

6 Vehicles for shadow population have been reduced to 20%. Refer to Figure 2-1 for additional information.

Braidwood Generating Station Evacuation Time Estimate 3-24 KLD Engineering, P.C.

Rev. 0

4 ESTIMATION OF HIGHWAY CAPACITY The ability of the road network to service vehicle demand is a major factor in determining how rapidly an evacuation can be completed. The capacity of a road is defined as the maximum hourly rate at which persons or vehicles can reasonably be expected to traverse a point or uniform section of a lane of roadway during a given time period under prevailing roadway, traffic and control conditions, as stated in the 2010 Highway Capacity Manual (TRB, 2010).

In discussing capacity, different operating conditions have been assigned alphabetical designations, A through F, to reflect the range of traffic operational characteristics. These designations have been termed "Levels of Service" (LOS). For example, LOS A connotes free-flow and high-speed operating conditions; LOS F represents a forced flow condition. LOS E describes traffic operating at or near capacity.

Another concept, closely associated with capacity, is "Service Volume" (SV). Service volume is defined as "The maximum hourly rate at which vehicles, bicycles or persons reasonably can be expected to traverse a point or uniform section of a roadway during an hour under specific assumed conditions while maintaining a designated level of service." This definition is similar to that for capacity. The major distinction is that values of SV vary from one LOS to another, while capacity is the service volume at the upper bound of LOS E, only.

This distinction is illustrated in Exhibit 11-17 of the HCM 2010. As indicated there, the SV varies with Free Flow Speed (FFS), and LOS. The SV is calculated by the DYNEV II simulation model, based on the specified link attributes, FFS, capacity, control device and traffic demand.

Other factors also influence capacity. These include, but are not limited to:

Lane width Shoulder width

" Pavement condition Horizontal and vertical alignment (curvature and grade)

" Percent truck traffic Control device (and timing, if it is a signal)

" Weather conditions (rain, snow, fog, wind speed, ice)

These factors are considered during the road survey and in the capacity estimation process; some factors have greater influence on capacity than others. For example, lane and shoulder width have only a limited influence on Base Free Flow Speed (BFFS1) according to Exhibit 15-7 of the HCM. Consequently, lane and shoulder widths at the narrowest points were observed during the road survey and these observations were recorded, but no detailed measurements of lane or shoulder width were taken. Horizontal and vertical alignment can influence both FFS and capacity. The estimated FFS were measured using the survey vehicle's speedometer and observing local traffic, under free flow conditions. Capacity is estimated from the procedures of 1 A very rough estimate of BFFS might be taken as the posted speed limit plus 10 mph (HCM 2010 Page 15-15)

Braidwood Generating Station 4-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

the 2010 HCM. For example, HCM Exhibit 7-1(b) shows the sensitivity of Service Volume at the upper bound of LOS D to grade (capacity is the Service Volume at the upper bound of LOS E).

As discussed in Section 2.3, it is necessary to adjust capacity figures to represent the prevailing conditions during inclement weather. Based on limited empirical data, weather conditions such as rain reduce the values of free speed and of highway capacity by approximately 10 percent. Over the last decade new studies have been made on the effects of rain on traffic capacity. These studies indicate a range of effects between 5 and 20 percent depending on wind speed and precipitation rates. As indicated in Section 2.3, we employ a reduction in free speed and in highway capacity of 10 percent and 20 percent for rain and snow, respectively.

Since congestion arising from evacuation may be significant, estimates of roadway capacity must be determined with great care. Because of its importance, a brief discussion of the major factors that influence highway capacity is presented in this section.

Rural highways generally consist of: (1) one or more uniform sections with limited access (driveways, parking areas) characterized by "uninterrupted" flow; and (2) approaches to at-grade intersections where flow can be "interrupted" by a control device or by turning or crossing traffic at the intersection. Due to these differences, separate estimates of capacity must be made for each section. Often, the approach to the intersection is widened by the addition of one or more lanes (turn pockets or turn bays), to compensate for the lower capacity of the approach due to the factors there that can interrupt the flow of traffic. These additional lanes are recorded during the field survey and later entered as input to the DYNEV II system.

4.1 Capacity Estimations on Approaches to Intersections At-grade intersections are apt to become the first bottleneck locations under local heavy traffic volume conditions. This characteristic reflects the need to allocate access time to the respective competing traffic streams by exerting some form of control. During evacuation, control at critical intersections will often be provided by traffic control personnel assigned for that purpose, whose directions may supersede traffic control devices. The existing traffic management plans documented in the county emergency plans are extensive and were adopted without change.

The per-lane capacity of an approach to a signalized intersection can be expressed (simplistically) in the following form:

Qcapm = (

) X (UCL)

=(

3 i M )XPm where:

Qcap,m Capacity of a single lane of traffic on an approach, which executes movement, m, upon entering the intersection; vehicles per hour (vph)

Braidwood Generating Station 4-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

hm Mean qu'e-ue discharge headway of vehicles on this lane that are executing movement, m; seconds per vehicle G

=

Mean duration of GREEN time servicing vehicles that are executing movement, m, for each signal cycle; seconds L

=

Mean "lost time" for each signal phase servicing movement, m; seconds C

=

Duration of each signal cycle; seconds Pm

=

Proportion of GREEN time allocated for vehicles executing movement, m, from this lane. This value is specified as part of the control treatment.

m The movement executed by vehicles after they enter the intersection: through, left-turn, right-turn, and diagonal.

The turn-movement-specific mean discharge headway hm, depends in a complex way upon many factors: roadway geometrics, turn percentages, the extent of conflicting traffic streams, the control treatment, and others. A primary factor is the value of "saturation queue discharge headway", hsat, which applies to through vehicles that are not impeded by other conflicting traffic streams. This value, itself, depends upon many factors including motorist behavior.

Formally, we can write, hm = fm(hsat, F1, F2,...)

where:

hsat

=

Saturation discharge headway for through vehicles; seconds per vehicle F1,F2

=

The various known factors influencing hm fM()

=

Complex function relating hm to the known (or estimated) values of hsat, F1, F2,...

The estimation of hm for specified values of hsat, F1, F2,... is undertaken within the DYNEV II simulation model by a mathematical model (Lieberman, 1980), (McShane, 1980), (Lieberman, 2012). The resulting values for hm always satisfy the condition:

hm Ž! hsat That is, the turn-movement-specific discharge headways are always greater than, or equal to the saturation discharge headway for through vehicles.

These headways (or its inverse equivalent, "saturation flow rate"), may be determined by observation or using the procedures of the HCM 2010.

The above discussion is necessarily brief given the scope of this ETE report and the complexity of the subject of intersection capacity. In fact, Chapters 18, 19 and 20 in the HCM 2010 address this topic. The factors, F1, F2,..., influencing saturation flow rate are identified in equation (18-5) of the HCM 2010.

Braidwood Generating Station 4-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

The traffic signals within the EPZ and Shadow Region are modeled using representative phasing plans and phase durations obtained as part of the field data collection. Traffic responsive signal installations allow the proportion of green time allocated (P1m) for each approach to each intersection to be determined by the expected traffic volumes on each approach during evacuation circumstances. The amount of green time (G) allocated is subject to maximum and minimum phase duration constraints; 2 seconds of yellow time are indicated for each signal phase and 1 second of all-red time is assigned between signal phases, typically. If a signal is pre-timed, the yellow and all-red times observed during the road survey are used. A lost time (L) of 2.0 seconds is used for each signal phase in the analysis.

4.2 Capacity Estimation along Sections of Highway The capacity of highway sections -- as distinct from approaches to intersections -- is a function of roadway geometrics, traffic composition (e.g. percent heavy trucks and buses in the traffic stream) and, of course, motorist behavior. There is a fundamental relationship which relates service volume (i.e. the number of vehicles serviced within a uniform highway section in a given time period) to traffic density. The top curve in Figure 4-1 illustrates this relationship.

As indicated, there are two flow regimes: (1) Free Flow (left side of curve); and (2) Forced Flow (right side). In the Free Flow regime, the traffic demand is fully serviced; the service volume increases as demand volume and density increase, until the service volume attains its maximum value, which is the capacity of the highway section. As traffic demand and the resulting highway density increase beyond this "critical" value, the rate at which traffic can be serviced (i.e. the service volume) can actually decline below capacity ("capacity drop"). Therefore, in order to realistically represent traffic performance during congested conditions (i.e. when demand exceeds capacity), it is necessary to estimate the service volume, VF, under congested conditions.

The value of VF can be expressed as:

VF = R x Capacity where:

R Reduction factor which is less than unity We have employed a value of R=0.90. The advisability of such a capacity reduction factor is based upon empirical studies that identified a fall-off in the service flow rate when congestion occurs at "bottlenecks" or "choke points" on a freeway system. Zhang and Levinson describe a research program that collected data from a computer-based surveillance system (loop detectors) installed on the Interstate Highway System, at 27 active bottlenecks in the twin cities metro area in Minnesota over a 7-week period (Zhang, 2004). When flow breakdown occurs, queues are formed which discharge at lower flow rates than the maximum capacity prior to observed breakdown. These queue discharge flow (QDF) rates vary from one location to the next and also vary by day of week and time of day based upon local circumstances. The cited reference presents a mean QDF of 2,016 passenger cars per hour per lane (pcphpl). This figure compares with the nominal capacity estimate of 2,250 pcphpl estimated for the ETE and Braidwood Generating Station 4-4 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

indicated in Appendix K for freeway links.

The ratio of these two numbers is 0.896 which translates into a capacity reduction factor of 0.90.

Since the principal objective of evacuation time estimate analyses is to develop a "realistic" estimate of evacuation times, use of the representative value for this capacity reduction factor (R=0.90) is justified. This factor is applied only when flow breaks down, as determined by the simulation model.

Rural roads, like freeways, are classified as "uninterrupted flow" facilities. (This is in contrast with urban street systems which have closely spaced signalized intersections and are classified as "interrupted flow" facilities.) As such, traffic flow along rural roads is subject to the same effects as freeways in the event traffic demand exceeds the nominal capacity, resulting in queuing and lower QDF rates. As a practical matter, rural roads rarely break down at locations away from intersections.

Any breakdowns on rural roads are generally experienced at intersections where other model logic applies, or at lane drops which reduce capacity there.

Therefore, the application of a factor of 0.90 is appropriate on rural roads, but rarely, if ever, activated.

The estimated value of capacity is based primarily upon the type of facility and on roadway geometrics. Sections of roadway with adverse geometrics are characterized by lower free-flow speeds and lane capacity. Exhibit 15-30 in the Highway Capacity Manual was referenced to estimate saturation flow rates. The impact of narrow lanes and shoulders on free-flow speed and on capacity is not material, particularly when flow is predominantly in one direction as is the case during an evacuation.

The procedure used here was to estimate "section" capacity, VE, based on observations made traveling over each section of the evacuation network, based on the posted speed limits and travel behavior of other motorists and by reference to the 2010 HCM. The DYNEV II simulation model determines for each highway section, represented as a network link, whether its capacity would be limited by the "section-specific" service volume, VE, or by the intersection-specific capacity. For each link, the model selects the lower value of capacity.

Braidwood Generating Station 4-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

4.3 Application to the BWD Study Area As part of the development of the link-node analysis network for the study area, an estimate of roadway capacity is required. The source material for the capacity estimates presented herein is contained in:

2010 Highway Capacity Manual (HCM)

Transportation Research Board National Research Council Washington, D.C. (TRB, 2010)

The highway system in the study area consists primarily of three categories of roads and, of course, intersections:

Two-Lane roads: Local, State Multi-Lane Highways (at-grade)

Freeways Each of these classifications will be discussed.

4.3.1 Two-Lane Roads Ref: HCM Chapter 15 (TRB, 2010)

Two lane roads comprise the majority of highways within the EPZ. The per-lane capacity of a two-lane highway is estimated at 1,700 passenger cars per hour (pc/h).

This estimate is essentially independent of the directional distribution of traffic volume except that, for extended distances, the two-way capacity will not exceed 3,200 pc/h. The HCM procedures then estimate Level of Service (LOS) and Average Travel Speed. The DYNEV II simulation model accepts the specified value of capacity as input and computes average speed based on the time-varying demand: capacity relations.

Based on the field survey and on expected traffic operations associated with evacuation scenarios:

Most sections of two-lane roads within the EPZ are classified as "Class I", with "level terrain"; some are "rolling terrain".

"Class II" highways are mostly those within urban and suburban centers.

4.3.2 Multi-Lane Highway Ref: HCM Chapter 14 (TRB, 2010)

Exhibit 14-2 of the HCM 2010 presents a set of curves that indicate a per-lane capacity ranging from approximately 1,900 to 2,200 pc/h, for free-speeds of 45 to 60 mph, respectively. Based on observation, the multi-lane highways outside of urban areas within the EPZ service traffic with free-speeds in this range. The actual time-varying speeds computed by the simulation model reflect the demand: capacity relationship and the impact of control at intersections. A Braidwood Generating Station 4-6 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

conservative estimate of per-lane capacity of 1,900 pc/h is adopted for this study for multi-lane highways outside of urban areas, as shown in Appendix K.

4.3.3 Freeways Ref: HCM Chapters 10, 11, 12, 13 (TRB, 2010)

Chapter 10 of the HCM 2010 describes a procedure for integrating the results obtained in Chapters 11, 12 and 13, which compute capacity and LOS for freeway components. Chapter 10 also presents a discussion of simulation models. The DYNEV II simulation model automatically performs this integration process.

Chapter 11 of the HCM 2010 presents procedures for estimating capacity and LOS for "Basic Freeway Segments". Exhibit 11-17 of the HCM 2010 presents capacity vs. free speed estimates, which are provided below.

Free Speed (mph):

55 60 65 70+

Per-Lane Capacity (pc/h):

2250 2300 2350 2400 The inputs to the simulation model are highway geometrics, free-speeds and capacity based on field observations. The simulation logic calculates actual time-varying speeds based on demand:

capacity relationships. A conservative estimate of per-lane capacity of 2,250 pc/h is adopted for this study for freeways, as shown in Appendix K.

Chapter 12 of the HCM 2010 presents procedures for estimating capacity, speed, density and LOS for freeway weaving sections. The simulation model contains logic that relates speed to demand volume: capacity ratio.

The value of capacity obtained from the computational procedures detailed in Chapter 12 depends on the "Type" and geometrics of the weaving segment and on the "Volume Ratio" (ratio of weaving volume to total volume).

Chapter 13 of the HCM 2010 presents procedures for estimating capacities of ramps and of "merge" areas. There are three significant factors to the determination of capacity of a ramp-freeway junction: The capacity of the freeway immediately downstream of an on-ramp or immediately upstream of an off-ramp; the capacity of the ramp roadway; and the maximum flow rate entering the ramp influence area.

In most cases, the freeway capacity is the controlling factor. Values of this merge area capacity are presented in Exhibit 13-8 of the HCM 2010, and depend on the number of freeway lanes and on the freeway free speed.

Ramp capacity is presented in Exhibit 13-10 and is a function of the ramp free flow speed. The DYNEV II simulation model logic simulates the merging operations of the ramp and freeway traffic in accord with the procedures in Chapter 13 of the HCM 2010. If congestion results from an excess of demand relative to capacity, then the model allocates service appropriately to the two entering traffic streams and produces LOS F conditions (The HCM does not address LOS F explicitly).

Braidwood Generating Station 4-7 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

4.3.4 Intersections Ref: HCM Chapters 18, 19, 20, 21 (TRB, 2010)

Procedures for estimating capacity and LOS for approaches to intersections are presented in Chapter 18 (signalized intersections), Chapters 19, 20 (un-signalized intersections) and Chapter 21 (roundabouts). The complexity of these computations is indicated by the aggregate length of these chapters. The DYNEV II simulation logic is likewise complex.

The simulation model explicitly models intersections: Stop/yield controlled intersections (both 2-way and all-way) and traffic signal controlled intersections. Where intersections are controlled by fixed time controllers, traffic signal timings are set to reflect average (non-evacuation) traffic conditions. Actuated traffic signal settings respond to the time-varying demands of evacuation traffic to adjust the relative capacities of the competing intersection approaches.

The model is also capable of modeling the presence of manned traffic control. At specific locations where it is advisable or where existing plans call for overriding existing traffic control to implement manned control, the model will use actuated signal timings that reflect the presence of traffic guides. At locations where a special traffic control strategy (continuous left-turns, contra-flow lanes) is used, the strategy is modeled explicitly. Where applicable, the location and type of traffic control for nodes in the evacuation network are noted in Appendix K. The characteristics of the ten highest volume signalized intersections are detailed in Appendix J.

4.4 Simulation and Capacity Estimation Chapter 6 of the HCM is entitled, "HCM and Alternative Analysis Tools." The chapter discusses the use of alternative tools such as simulation modeling to evaluate the operational performance of highway networks. Among the reasons cited in Chapter 6 to consider using simulation as an alternative analysis tool is:

"The system under study involves a group of different facilities or travel modes with mutual interactions invoking several procedural chapters of the HCM. Alternative tools are able to analyze these facilities as a single system."

This statement succinctly describes the analyses required to determine traffic operations across an area encompassing an EPZ operating under evacuation conditions. The model utilized for this study, DYNEV II, is further described in Appendix C. It is essential to recognize that simulation models do not replicate the methodology and procedures of the HCM - they replace these procedures by describing the complex interactions of traffic flow and computing Measures of Effectiveness (MOE) detailing the operational performance of traffic over time and by location. The DYNEV II simulation model includes some HCM 2010 procedures only for the purpose of estimating capacity.

All simulation models must be calibrated properly with field observations that quantify the performance parameters applicable to the analysis network. Two of the most important of Braidwood Generating Station 4-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

these are: (1) Free flow speed (FFS); and (2) saturation headway, hsat. The first of these is estimated by direct observation during the road survey; the second is estimated using the concepts of the HCM 2010, as described earlier. These parameters are listed in Appendix K, for each network link.

Volume, vph Drop R

Qs Density, vpm Speed, mph Vf RvJ ensity, vpm kf kopt 1s Figure 4-1. Fundamental Diagrams Braidwood Generating Station Evacuation Time Estimate 4-9 KLD Engineering, P.C.

Rev. 0

5 ESTIMATION OF TRIP GENERATION TIME Federal Government guidelines (see NUREG/CR-7002) specify that the planner estimate the distributions of elapsed times associated with mobilization activities undertaken by the public to prepare for the evacuation trip. The elapsed time associated with each activity is represented as a statistical distribution reflecting differences between members of the public.

The quantification of these activity-based distributions relies largely on the results of the telephone survey. We define the sum of these distributions of elapsed times as the Trip Generation Time Distribution.

5.1 Background

In general, an accident at a nuclear power plant is characterized by the following Emergency Classification Levels (see Appendix I of NUREG 0654 for details):

1.

Unusual Event

2. Alert
3. Site Area Emergency
4. General Emergency At each level, the Federal guidelines specify a set of Actions to be undertaken by the Licensee, and by State and Local offsite authorities. As a Planning Basis we will adopt a conservative posture, in accordance with Section 1.2 of NUREG/CR-7002, that a rapidly escalating accident will be considered in calculating the Trip Generation Time. We will assume:
1. The Advisory to Evacuate will be announced coincident with the siren notification.
2. Mobilization of the general population will commence within 15 minutes after the siren notification.
3.

ETE are measured relative to the Advisory to Evacuate.

We emphasize that the adoption of this planning basis is not a representation that these events will occur within the indicated time frame. Rather, these assumptions are necessary in order to:

1. Establish a temporal framework for estimating the Trip Generation distribution in the format recommended in Section 2.13 of NUREG/CR-6863.
2.

Identify temporal points of reference that uniquely define "Clear Time" and ETE.

It is likely that a longer time will elapse between the various classes of an emergency.

For example, suppose one hour elapses from the siren alert to the Advisory to Evacuate. In this case, it is reasonable to expect some degree of spontaneous evacuation by the public during this one-hour period. As a result, the population within the EPZ will be lower when the Advisory to Evacuate is announced, than at the time of the siren alert. In addition, many will engage in preparation activities to evacuate, in anticipation that an Advisory will be broadcast.

Thus, the time needed to complete the mobilization activities and the number of people remaining to evacuate the EPZ after the Advisory to Evacuate, will both be somewhat less than Braidwood Generating Station 5-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

the estimates presented in this report. Consequently, the ETE presented in this report are higher than the actual evacuation time, if this hypothetical situation were to take place.

The notification process consists of two events:

1. Transmitting information using the alert notification systems available within the EPZ (e.g. sirens, tone alerts, EAS broadcasts, loud speakers).
2. Receiving and correctly interpreting the information that is transmitted.

The population within the EPZ is dispersed over an area of 402 square miles and is engaged in a wide variety of activities. It must be anticipated that some time will elapse between the transmission and receipt of the information advising the public of an accident.

The amount of elapsed time will vary from one individual to the next depending on where that person is, what that person is doing, and related factors. Furthermore, some persons who will be directly involved with the evacuation process may be outside the EPZ at the time the emergency is declared. These people may be commuters, shoppers and other travelers who reside within the EPZ and who will return to join the other household members upon receiving notification of an emergency.

As indicated in Section 2.13 of NUREG/CR-6863, the estimated elapsed times for the receipt of notification can be expressed as a distribution reflecting the different notification times for different people within, and outside, the EPZ. By using time distributions, it is also possible to distinguish between different population groups and different day-of-week and time-of-day scenarios, so that accurate ETE may be computed.

For example, people at home or at work within the EPZ will be notified by siren, and/or tone alert and/or radio (if available). Those well outside the EPZ will be notified by telephone, radio, TV and word-of-mouth, with potentially longer time lags. Furthermore, the spatial distribution of the EPZ population will differ with time of day - families will be united in the evenings, but dispersed during the day. In this respect, weekends will differ from weekdays.

As indicated in Section 4.1 of NUREG/CR-7002, the information required to compute trip generation times is typically obtained from a telephone survey of EPZ residents. Such a survey was conducted in support of this ETE study. Appendix F discusses the survey sampling plan and documents the survey instrument and survey results. The remaining discussion will focus on the application of the trip generation data obtained from the telephone survey to the development of the ETE documented in this report.

Braidwood Generating Station 5-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

5.2 Fundamental Considerations The environment leading up to the time that people begin their evacuation trips consists of a sequence of events and activities. Each event (other than the first) occurs at an instant in time and is the outcome of an activity.

Activities are undertaken over a period of time. Activities may be in "series" (i.e. to undertake an activity implies the completion of all preceding events) or may be in parallel (two or more activities may take place over the same period of time). Activities conducted in series are functionally dependent on the completion of prior activities; activities conducted in parallel are functionally independent of one another. The relevant events associated with the public's preparation for evacuation are:

Event Number 1

2 3

4 5

Event Description Notification Awareness of Situation Depart Work Arrive Home Depart on Evacuation Trip Associated with each sequence of events are one or more activities, as outlined below:

Table 5-1. Event Sequence for Evacuation Activities SActivit Distri 1-)2 Receive Notification 1

2 -- 3 Prepare to Leave Work 2

2,3 -)4 Travel Home 3

2,4-5 Prepare to Leave to Evacuate 4

N/A Snow Clearance 5

These relationships are shown graphically in Figure 5-1.

0 S

An Event is a 'state' that exists at a point in time (e.g., depart work, arrive home)

An Activity is a 'process' that takes place over some elapsed time (e.g., prepare to leave work, travel home)

As such, a completed Activity changes the 'state' of an individual (e.g. the activity, 'travel home' changes the state from 'depart work' to 'arrive home'). Therefore, an Activity can be described as an 'Event Sequence'; the elapsed times to perform an event sequence vary from one person to the next and are described as statistical distributions on the following pages.

An employee who lives outside the EPZ will follow sequence (c) of Figure 5-1. A household Braidwood Generating Station Evacuation Time Estimate 5-3 KD Engineering, P.C.

Rev. 0

within the EPZ that has one or more commuters at work, and will await their return before beginning the evacuation trip will follow the first sequence of Figure 5-1(a). A household within the EPZ that has no commuters at work, or that will not await the return of any commuters, will follow the second sequence of Figure 5-1(a), regardless of day of week or time of day.

Households with no commuters on weekends or in the evening/night-time, will follow the applicable sequence in Figure 5-1(b). Transients will always follow one of the sequences of Figure 5-1(b). Some transients away from their residence could elect to evacuate immediately without returning to the residence, as indicated in the second sequence.

It is seen from Figure 5-1, that the Trip Generation time (i.e. the total elapsed time from Event 1 to Event 5) depends on the scenario and will vary from one household to the next.

Furthermore, Event 5 depends, in a complicated way, on the time distributions of all activities preceding that event. That is, to estimate the time distribution of Event 5, we must obtain estimates of the time distributions of all preceding events. For this study, we adopt the conservative posture that all activities will occur in sequence.

In some cases, assuming certain events occur strictly sequential (for instance, commuter returning home before beginning preparation to leave, or removing snow only after the preparation to leave) can result in rather conservative (that is, longer) estimates of mobilization times. It is reasonable to expect that at least some parts of these events will overlap for many households, but that assumption is not made in this study.

Braidwood Generating Station Evacuation Time Estimate 5-4 KLD Engineering, P.C.

Rev. 0

1 Ah 2

-Ah 3

4 5

Residents Residents MW

-W

-1W 1

As 2

5 Af 0

Households wait for Commuters1 Households without Commuters and households who do not wait for Commuters W

W W

(a) Accident occurs during miweek, at miday; year round I

Residents, Transients away from Residence Residents, Transients at Residence 1

2 4

5

_w MW Return to residence, then evacuate Residents at home; transients evacuate directly 1

2 5

(b) Accident occurs during weekend or during the evening2 1

2 3,5 (c) Employees who live outside the EPZ ACTIVITIES 1 -

2 Receive Notification 2 --

3 Prepare to Leave Work 2, 3 _

4 Travel Home 2, 4 1 5 Prepare to Leave to Evacuate Activities Consume Time EVENTS

1. Notification
2. Aware of situation
3. Depart work
4. Arrive home
5. Depart on evacuation trip 1 Applies for evening and weekends also if commuters are at work.

2 Applies throughout the year for transients.

Figure 5-1. Events and Activities Preceding the Evacuation Trip Braidwood Generating Station Evacuation Time Estimate 5-5 KLD Engineering, P.C.

Rev. 0

5.3 Estimated Time Distributions of Activities Preceding Event 5 The time distribution of an event is obtained by "summing" the time distributions of all prior contributing activities. (This "summing" process is quite different than an algebraic sum since it is performed on distributions - not scalar numbers).

Time Distribution No. 1, Notification Process: Activity 1 --> 2 Federal regulations (10CFR 50 Appendix E, Item IV.D.3) stipulate, "[t]he design objective of the prompt public alert and notification system shall be to have the capability to essentially complete the initial alerting and initiate notification of the public within the plume exposure pathway EPZ within about 15 minutes" (NRC, 2011b). Furthermore, Item 2 of Section B in Appendix 3 of NUREG/CR-0654/FEMA-REP-1 states that "special arrangements will be made to assure 100%

coverage within 45 minutes of the population who may not have received the initial notification within the entire plume exposure EPZ" (NRC, 1980b). Given the federal regulations and guidance, and the presence of sirens within the EPZ, it is assumed that 100% of the population in the EPZ can be notified within 45 minutes. The assumed distribution for notifying the EPZ population is provided in Table 5-2.

Table 5-2. Time Distribution for Notifying the Public Elase Tim Pecn of (Minutes).

Pouato Notfie 0

0%

5 7%

10 13%

15 27%

20 47%

25 66%

30 87%

35 92%

40 97%

45 100%

Braidwood Generating Station Evacuation Time Estimate 5-6 KLD Engineering, P.C.

Rev. 0

Distribution No. 2. Prepare to Leave Work: Activity 2 -> 3 It is reasonable to expect that the vast majority of business enterprises within the EPZ will elect to shut down following notification and most employees would leave work quickly. Commuters, who work outside the EPZ could, in all probability, also leave quickly since facilities outside the EPZ would remain open and other personnel would remain. Personnel or farmers responsible for equipment/livestock would require additional time to secure their facility. The distribution of Activity 2 -> 3 shown in Table 5-3 reflects data obtained by the telephone survey. This distribution is plotted in Figure 5-2.

Table 5-3. Time Distribution for Employees to Prepare to Leave Work Cumulativ 0

0%

15 71%

30 88%

45 94%

60 98%

75 100%

NOTE: The survey data was normalized to distribute the "Don't know" response. That is, the sample was reduced in size to include only those households who responded to this question. The underlying assumption is that the distribution of this activity for the "Don't know" responders, if the event takes place, would be the same as those responders who provided estimates.

Braidwood Generating Station Evacuation Time Estimate 5-7 KLD Engineering, P.C.

Rev. 0

Distribution No. 3, Travel Home: Activity 3 -> 4 These data are provided directly by those households which responded to the telephone survey. This distribution is plotted in Figure 5-2 and listed in Table 5-4.

Table 5-4. Time Distribution for Commuters to Travel Home 0

0%

15 49%

30 80%

45 91%

60 96%

75 100%

NOTE: The survey data was normalized to distribute the "Don't know" response Distribution No. 4, Prepare to Leave Home:

Activity 2, 4 -> 5 These data are provided directly by those households which responded to the telephone survey. This distribution is plotted in Figure 5-2 and listed in Table 5-5.

Table 5-5. Time Distribution for Population to Prepare to Evacuate

.Cumulativ 0

0%

20 31%

40 73%

60 88%

90 96%

120 100%

NOTE: The survey data was normalized to distribute the "Don't know" response Braidwood Generating Station Evacuation Time Estimate 5-8 KLD Engineering, P.C.

Rev. 0

Distribution No. 5, Snow Clearance Time Distribution Inclement weather scenarios involving snowfall must address the time lags associated with snow clearance.

It is assumed that snow equipment is mobilized and deployed during the snowfall to maintain passable roads. The general consensus is that the snow-plowing efforts are generally successful for all but the most extreme blizzards when the rate of snow accumulation exceeds that of snow clearance over a period of many hours.

Consequently, it is reasonable to assume that the highway system will remain passable - albeit at a lower capacity - under the vast majority of snow conditions. Nevertheless, for the vehicles to gain access to the highway system, it may be necessary for driveways and employee parking lots to be cleared to the extent needed to permit vehicles to gain access to the roadways.

These clearance activities take time; this time must be incorporated into the trip generation time distributions. This distribution is plotted in Figure 5-2 and listed in Table 5-6.

The data in Table 5-6 are adapted from a survey conducted of households in the Duane Arnold Energy Center (DAEC) EPZ in 2012. DAEC is located in Iowa, 193 miles west-northwest of BWD.

It is assumed that snowfall and snow removal times are comparable in both EPZs.

Table 5-6. Time Distribution for Population to Clear 6-8" of Snow

.Cumulativ 0

46%

15 60%

30 82%

45 88%

60 96%

75 97%

90 98%

105 98%

120 100%

NOTE: The survey data was normalized to distribute the "Don't know" response Braidwood Generating Station 5-9 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Mobilization Activities 100%

0 N

0 bA CL Ei 0.

CL 0

0.

80%

60%

40%

20%

L.................

'000

//f

//

Notification Prepare to Leave Work Travel Home Prepare to Leave Home

-Clear Snow 0%

0 15 30 45 60 75 90 105 120 Elapsed Time from Start of Mobilization Activity (mi)

Figure 5-2. Evacuation Mobilization Activities Braidwood Generating Station Evacuation Time Estimate 5-10 KLD Engineering, P.C.

Rev. 0

5.4 Calculation of Trip Generation Time Distribution The time distributions for each of the mobilization activities presented herein must be combined to form the appropriate Trip Generation Distributions. As discussed above, this study assumes that the stated events take place in sequence such that all preceding events must be completed before the current event can occur. For example, if a household awaits the return of a commuter, the work-to-home trip (Activity 3 -> 4) must precede Activity 4 -+ 5.

To calculate the time distribution of an event that is dependent on two sequential activities, it is necessary to "sum" the distributions associated with these prior activities. The distribution summing algorithm is applied repeatedly as shown to form the required distribution. As an outcome of this procedure, new time distributions are formed; we assign "letter" designations to these intermediate distributions to describe the procedure. Table 5-7 presents the summing procedure to arrive at each designated distribution.

Table 5-7. Mapping Distributions to Events Apl "Smmng Aloih To Disriuto.

Obaie Even Defne Distributions 1 and 2 Distribution A Event 3 Distributions A and 3 Distribution B Event 4 Distributions B and 4 Distribution C Event 5 Distributions 1 and 4 Distribution D Event 5 Distributions C and 5 Distribution E Event 5 Distributions D and 5 Distribution F Event 5 Table 5-8 presents a description of each of the final trip generation distributions achieved after the summing process is completed.

Braidwood Generating Station Evacuation Time Estimate 5-11 KLD Engineering, P.C.

Rev. 0

Table 5-8. Description of the Distributions Ditibto Description Time distribution of commuters departing place of work (Event 3). Also applies A

to employees who work within the EPZ who live outside, and to Transients within the EPZ.

B Time distribution of commuters arriving home (Event 4).

Time distribution of residents with commuters who return home, leaving home to begin the evacuation trip (Event 5).

D Time distribution of residents without commuters returning home, leaving home to begin the evacuation trip (Event 5).

E Time distribution of residents with commuters who return home, leaving home to begin the evacuation trip, after snow clearance activities (Event 5).

Time distribution of residents with no commuters returning home, leaving to begin the evacuation trip, after snow clearance activities (Event 5).

5.4.1 Statistical Outliers As already mentioned, some portion of the survey respondents answer "don't know" to some questions or choose to not respond to a question. The mobilization activity distributions are based upon actual responses.

But, it is the nature of surveys that a few numeric responses are inconsistent with the overall pattern of results. An example would be a case in which for 500 responses, almost all of them estimate less than two hours for a given answer, but 3 say "four hours" and 4 say "six or more hours".

These "outliers" must be considered: are they valid responses, or so atypical that they should be dropped from the sample?

In assessing outliers, there are three alternates to consider:

1) Some responses with very long times may be valid, but reflect the reality that the respondent really needs to be classified in a different population subgroup, based upon special needs;
2) Other responses may be unrealistic (6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to return home from commuting distance, or 2 days to prepare the home for departure);
3) Some high values are representative and plausible, and one must not cut them as part of the consideration of outliers.

The issue of course is how to make the decision that a given response or set of responses are to be considered "outliers" for the component mobilization activities, using a method that objectively quantifies the process.

There is considerable statistical literature on the identification and treatment of outliers singly or in groups, much of which assumes the data is normally distributed and some of which uses non-Braidwood Generating Station 5-12 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

parametric methods to avoid that assumption. The literature cites that limited work has been done directly on outliers in sample survey responses.

In establishing the overall mobilization time/trip generation distributions, the following principles are used:

1)

It is recognized that the overall trip generation distributions are conservative estimates, because they assume a household will do the mobilization activities sequentially, with no overlap of activities;

2) The individual mobilization activities (prepare to leave work, travel home, prepare home, clear snow) are reviewed for outliers, and then the overall trip generation distributions are created (see Figure 5-1, Table 5-7, Table 5-8);
3) Outliers can be eliminated either because the response reflects a special population (e.g.

special needs, transit dependent) or lack of realism, because the purpose is to estimate trip generation patterns for personal vehicles;

4) To eliminate outliers, a) the mean and standard deviation of the specific activity are estimated from the responses, b) the median of the same data is estimated, with its position relative to the mean
noted, c) the histogram of the data is inspected, and d) all values greater than 3.5 standard deviations are flagged for attention, taking special note of whether there are gaps (categories with zero entries) in the histogram display.

In general, only flagged values more than 4 standard deviations from the mean are allowed to be considered outliers, with gaps in the histogram expected.

When flagged values are classified as outliers and dropped, steps "a" to "d" are repeated.

Braidwood Generating Station 5-13 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

5) As a practical matter, even with outliers eliminated by the above, the resultant histogram, viewed as a cumulative distribution, is not a normal distribution. A typical situation that results is shown below in Figure 5-3.

100.0%

90.0%

80.0%

L 70.0%

5 60.0%

5 50.0%

.~40.0%

30.0%

E U

20.0%

10.0%

0.0%

LA UA Lq LA V!

Li LAi LA Li LA LA LA LA LA LA LA r-4

-4 C14 r4 cn m

4 LA LA to 60 cn

ý4 Center of Interval (minutes)

-Cumulative Data Cumulative Normal Figure 5-3. Comparison of Data Distribution and Normal Distribution

6) In particular, the cumulative distribution differs from the normal distribution in two key aspects, both very important in loading a network to estimate evacuation times:

Most of the real data is to the left of the "normal" curve above, indicating that the network loads faster for the first 80-85% of the vehicles, potentially causing more (and earlier) congestion than otherwise modeled; The last 10-15% of the real data "tails off' slower than the comparable "normal" curve, indicating that there is significant traffic still loading at later times.

Because these two features are important to preserve, it is the histogram of the data that is used to describe the mobilization activities, not a "normal" curve fit to the data. One could consider other distributions, but using the shape of the actual data curve is unambiguous and preserves these important features;

7) With the mobilization activities each modeled according to Steps 1-6, including preserving the features cited in Step 6, the overall (or total) mobilization times are constructed.

Braidwood Generating Station 5-14 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

This is done by using the data sets and distributions under different scenarios (e.g. commuter returning, no commuter returning, no snow or snow in each). In general, these are additive, using weighting based upon the probability distributions of each element; Figure 5-4 presents the combined trip generation distributions designated A, C, D, E and F. These distributions are presented on the same time scale. (As discussed earlier, the use of strictly additive activities is a conservative approach, because it makes all activities sequential - preparation for departure follows the return of the commuter; snow clearance follows the preparation for departure, and so forth. In practice, it is reasonable that some of these activities are done in parallel, at least to some extent - for instance, preparation to depart begins by a household member at home while the commuter is still on the road.)

The mobilization distributions that result are used in their tabular/graphical form as direct inputs to later computations that lead to the ETE.

The DYNEV II simulation model is designed to accept varying rates of vehicle trip generation for each origin centroid, expressed in the form of histograms. These histograms, which represent Distributions A, C, D, E and F, properly displaced with respect to one another, are tabulated in Table 5-9 (Distribution B, Arrive Home, omitted for clarity).

The final time period (15) is 600 minutes long. This time period is added to allow the analysis network to clear, in the event congestion persists beyond the trip generation period. Note that there are no trips generated during this final time period.

5.4.2 Staged Evacuation Trip Generation As defined in NUREG/CR-7002, staged evacuation consists of the following:

1. Sub-areas comprising the 2 mile region are advised to evacuate immediately
2. Sub-areas comprising regions extending from 2 to 5 miles downwind are advised to shelter in-place while the 2 mile region is cleared
3. As vehicles evacuate the 2 mile region, sheltered people from 2 to 5 miles downwind continue preparation for evacuation
4. The population sheltering in the 2 to 5 mile region are advised to begin evacuating when approximately 90% of those originally within the 2 mile region evacuate across the 2 mile region boundary
5. Non-compliance with the shelter recommendation is the same as the shadow evacuation percentage of 20%

Assumptions

1. The EPZ population in Sub-areas beyond 5 miles will react as does the population in the 2 to 5 mile region; that is they will first shelter, then evacuate after the 90th percentile ETE for the 2 mile region
2. The population in the Shadow Region beyond the EPZ boundary, extending to approximately 15 miles radially from the plant, will react as they do for all non-staged Braidwood Generating Station 5-15 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

evacuation scenarios. That is 20% of these households will elect to evacuate with no shelter delay.

3. The transient population will not be expected to stage their evacuation because of the limited sheltering options available to people who may be at parks, on a beach, or at other venues. Also, notifying the transient population of a staged evacuation would prove difficult.
4. Employees will also be assumed to evacuate without first sheltering.

Procedure

1. Trip generation for population groups in the 2 mile region will be as computed based upon the results of the telephone survey and analysis.
2. Trip generation for the population subject to staged evacuation will be formulated as follows:
a.

Identify the 9 0 th percentile evacuation time for the sub-areas comprising the two mile region. This value, Tscen*, is obtained from simulation results. It will become the time at which the region being sheltered will be told to evacuate for each scenario.

b. The resultant trip generation curves for staging are then formed as follows:
i. The non-shelter trip generation curve is followed until a maximum of 20%

of the total trips are generated (to account for shelter non-compliance).

ii. No additional trips are generated until time Tscen iii.

Following time Tscen, the balance of trips are generated:

1. by stepping up and then following the non-shelter trip generation curve (if Tscen* is < max trip generation time) or
2. by stepping up to 100% (if Tscen* is > max trip generation time)
c.

Note: This procedure implies that there may be different staged trip generation distributions for different scenarios. NUREG/CR-7002 uses the statement "approximately 9 0 th percentile" as the time to end staging and begin evacuating.

The value of Tscen* is 2:00 for non-snow scenarios and 2:15 for snow scenarios.

ged trip generation distributions are created for the following population groups:

a.

Residents with returning commuters

b.

Residents without returning commuters

c.

Residents with returning commuters and snow conditions

d.

Residents without returning commuters and snow conditions

3. Staj Figure 5-5 presents the staged trip generation distributions for both residents with and without returning commuters; the 90th percentile two-mile evacuation time is 120 minutes for good weather and 135 minutes for snow scenarios. At the 9 0 th percentile evacuation time, 20% of the population (who normally would have completed their mobilization activities for an un-staged evacuation) advised to shelter has nevertheless departed the area. These people do not comply with the shelter advisory. Also included on the plot are the trip generation distributions for these groups as applied to the regions advised to evacuate immediately.

Braidwood Generating Station Evacuation Time Estimate 5-16 KLD Engineering, P.C.

Rev. 0

Since the 90th percentile evacuation time occurs before the end of the trip generation time, after the sheltered region is advised to evacuate, the shelter trip generation distribution rises to meet the balance of the non-staged trip generation distribution. Following time Tscen*, the balance of staged evacuation trips that are ready to depart are released within 15 minutes. After Tscen*+15, the remainder of evacuation trips are generated in accordance with the un-staged trip generation distribution.

Table 5-10 provides the trip generation histograms for staged evacuation.

5.4.3 Trip Generation for Waterways and Recreational Areas According to the Illinois Plan For Radiological Accidents (IPRA) for Braidwood (IPRA, 2012), the Grundy County Administrator will interface and coordinate with the responsible municipal officials to arrange transportation for transient populations if needed.

The Will County Emergency Management Director will interface with the responsible municipal Emergency Services and Disaster Agency Coordinators to arrange transportation with transient populations if needed.

Both the Illinois Department of Natural Resources, and the Kankakee County Sheriff's Department are involved in notifying recreational facilities within Kankakee County.

As indicated in Table 5-2, this study assumes 100% notification in 45 minutes. Table 5-9 indicates that all transients will have mobilized within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 45 minutes. It is assumed that this 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 45 minute timeframe is sufficient time for boaters, campers and other transients to return to their vehicles and begin their evacuation trip.

Braidwood Generating Station Evacuation Time Estimate 5-17 KLD Engineering, P.C.

Rev. 0

100 I.-

C 0

CO C

CL 4a CW 4-CL 80 60 40 20 Trip Generation Distributions Employees/Transie-nts Residents with Commuters Residents with no Commuters Res with Comm and Snow Res no Comm with Snow I

I I

I I

I Iý 0

0 30 60 90 120 150 180 Elapsed Time from Evacuation Advisory (min) 210 240 270 Figure 5-4. Comparison of Trip Generation Distributions Braidwood Generating Station Evacuation Time Estimate 5-18 KLD Engineering, P.C.

Rev. 0

Table 5-9. Trip Generation Histograms for the EPZ Population for Un-staged Evacuation Pecn o

Toa Trp Geeae Wihi Iniae Tim Period 0 Residents ~

~

~

~

0eiet-it eiet Residents0 wit Wihu0Cm uesihu Tim Duato Emlye rninsCm ues omtrnwCm uesSo Peio (M

n (Dstiuto A)

(Dsrbto A)

(Dsrbto C)

(Dsrbto0)(itiuto

)

(itiuinF 1

15 5%

5%

0%

2%

0%

1%

2 15 29%

29%

0%

11%

0%

6%

3 15 40%

40%

3%

23%

2%

14%

4 15 16%

16%

10%

26%

5%

18%

5 15 6%

6%

16%

18%

10%

19%

6 15 3%

3%

19%

9%

14%

14%

7 15 1%

1%

17%

4%

15%

10%

8 15 0%

0%

12%

4%

15%

7%

9 15 0%

0%

9%

2%

11%

4%

10 15 0%

0%

6%

1%

9%

3%

11 30 0%

0%

6%

0%

11%

3%

12 30 0%

0%

2%

0%

5%

1%

13 30 0%

0%

0%

0%

2%

0%

14 30 0%

0%

0%

0%

1%

0%

15 600 0%

0%

0%

0%

0%

0%

NOTE:

Shadow vehicles are loaded onto the analysis network (Figure 1-2) using Distributions C and E for good weather and snow, respectively.

Special event vehicles are loaded using Distribution A.

Braidwood Generating Station Evacuation Time Estimate 5-19 KLD Engineering, P.C.

Rev. 0

100 0.

I..W l-C.2 4 80 U

CL

"* 60 CL C

o 40 0.

0 2

0.

Staged and Un-staged Evacuation Trip Generation Employees / Transients Residents with Commuters Residents with no Commuters Res with Comm and Snow Res no Comm with Snow Staged Residents with Commuters Staged Residents with no Commuters Staged Residents with Commuters (Snow)

Staged Residents with no Commuters (Snow)

S r

0 0

30 60 90 120 150 180 210 240 270 Elapsed Time from Evacuation Advisory (min)

Figure 5-5. Comparison of Staged and Un-staged Trip Generation Distributions in the 2 to 5 Mile Region Braidwood Generating Station Evacuation Time Estimate 5-20 KLD Engineering, P.C.

Rev. 0

Table 5-10. Trip Generation Histograms for the EPZ Population for Staged Evacuation 1

15 0%

0%

0%

0%

2 15 0%

3%

0%

1%

3 15 1%

4%

0%

3%

4 15 2%

5%

1%

4%

5 15 3%

4%

2%

4%

6 15 4%

2%

3%

2%

7 15 3%

1%

3%

2%

8 15 2%

0%

3%

2%

9 15 71%

80%

2%

1%

10 15 6%

1%

67%

77%

11 30 6%

0%

11%

3%

12 30 2%

0%

5%

1%

13 30 0%

0%

2%

0%

14 30 0%

0%

1%

0%

15 600 0%

0%

0%

0%

  • Trip Generation for Employees and Transients (see Table 5-9) is the same for Un-staged and Staged Evacuation.

Braidwood Generating Station Evacuation Time Estimate 5-21 KLD Engineering, P.C.

Rev. 0

6 DEMAND ESTIMATION FOR EVACUATION SCENARIOS An evacuation "case" defines a combination of Evacuation Region and Evacuation Scenario.

The definitions of "Region" and "Scenario" are as follows:

Region A grouping of contiguous evacuating Sub-areas that forms either a "keyhole" sector-based area, or a circular area within the EPZ, that must be evacuated in response to a radiological emergency.

Scenario A combination of circumstances, including time of day, day of week, season, and weather conditions. Scenarios define the number of people in each of the affected population groups and their respective mobilization time distributions.

A total of 38 Regions were defined which encompass all the groupings of Sub-areas considered.

These Regions are defined in Table 6-1. The Sub-area configurations are identified in Figure 6-1. Each keyhole sector-based area consists of a central circle centered at the power plant, and three adjoining sectors, each with a central angle of 22.5 degrees, as per NUREG/CR-7002 guidance. The central sector coincides with the wind direction. These sectors extend to 5 miles from the plant (Regions R04 through R15) or to the EPZ boundary (Regions R16 through R25).

Regions R01, R02 and R03 represent evacuations of circular areas with radii of 2, 5 and 10 miles, respectively. Regions R26 through R38 are identical to Regions R02, and R04 through R15, respectively; however, those Sub-areas between 2 miles and 5 miles are staged until 90% of the 2-mile region (Region R01) has evacuated.

Each Sub-area that intersects the keyhole is included in the Region, unless specified otherwise in the Protective Action Recommendation (PAR) determination flowchart on page BW 4-3 of the Exelon Nuclear Radiological Emergency Plan Annex for Braidwood Station (Exelon, 2013).

Regions R13, R14, and R15 were specified in the Exelon emergency plan to use a two sector approach with wind towards the NNE/NE, SSE/SE, and SSW/S, respectively (Exelon, 2013).

There are instances when a small portion of a Sub-area is within the keyhole and the population within that small portion is low (500 people or 10% of Sub-area population, whichever is less).

Under those circumstances, the Sub-area would not be included in the Region.

A total of 14 Scenarios were evaluated for all Regions. Thus, there are a total of 38 x 14 = 532 evacuation cases. Table 6-2 is a description of all Scenarios.

Each combination of Region and Scenario implies a specific population to be evacuated. Table 6-3 presents the percentage of each population group estimated to evacuate for each Scenario.

Table 6-4 presents the vehicle counts for each Scenario for an evacuation of Region R03 - the entire EPZ.

The vehicle estimates presented in Section 3 are peak values. These peak values are adjusted depending on the Scenario and Region being considered, using Scenario and Region specific percentages, such that the average population is considered for each evacuation case. The Braidwood Generating Station 6-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Scenario percentages are presented in Table 6-3, while the regional percentages are provided in Table H-1. The percentages presented in Table 6-3 were determined as follows:

The number of residents with commuters during the week (when workforce is at its peak) is the product of 52% (the number of households with at least one commuter - see Figure F-3) and 40% (the number of households with a commuter that would await the return of the commuter prior to evacuating - see Figure F-5) which equals 21%. See assumption 3 in Section 2.3. It is estimated for weekend and evening scenarios that 10% of households with returning commuters will have a commuter at work during those times.

Employment is assumed to be at its peak (100%) during the winter, midweek, midday scenarios.

Employment is reduced slightly (96%) for summer, midweek, midday scenarios. This is based on the estimation that 50% of the employees commuting into the EPZ will be on vacation for a week during the approximate 12 weeks of summer. It is further estimated that those taking vacation will be uniformly dispersed throughout the summer with approximately 4% of employees vacationing each week. It is further estimated that only 10% of the employees are working in the evenings and during the weekends.

Transient activity is estimated to be at its peak during summer weekends when all transient facilities are open and operational. Transient activity during the week in the summertime is estimated to be at 65% of the weekend peak. Transient activity in the winter is estimated to be slightly less than half of the summer peak - 45% on weekends and 30% during the week - due to the large number of parks within the EPZ that are closed or less populated during winter months. Due to the presence of lodging facilities and campgrounds, transient activity during the evening is estimated to be 15% in the summer and 10% in the winter.

As noted in the shadow footnote to Table 6-3, the shadow percentages are computed using a base of 20% (see assumption 5 in Section 2.2); to include the employees within the Shadow Region who may choose to evacuate, the voluntary evacuation is multiplied by a scenario-specific proportion of employees to permanent residents in the shadow region. For example, using the values provided in Table 6-4 for Scenario 1, the shadow percentage is computed as follows:

20%x (+

1,602 21%

2 4,558 + 17,352)1=

One special event - a refueling outage at BWD - was considered as Scenario 13. Thus, the special event traffic is 100% evacuated for Scenario 13, and 0% for all other scenarios.

It is estimated that summer school enrollment is approximately 10% of enrollment during the regular school year for summer, midweek, midday scenarios. School is not in session during weekends and evenings, thus no buses for school children are needed under those circumstances. As discussed in Section 7, schools are in session during the winter season, midweek, midday and 100% of buses will be needed under those circumstances.

Braidwood Generating Station 6-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Transit buses for the transit-dependent population are set to 100% for all scenarios as it is assumed that the transit-dependent population is present in the EPZ for all scenarios.

External traffic is estimated to be reduced by 60% during evening scenarios and is 100% for all other scenarios.

Braidwood Generating Station Evacuation Time Estimate 6-3 KLD Engineering, P.C.

Rev. 0

Table 6-1. Description of Evacuation Regions Region Wind Direction Toward:

R16 N

R17 NNE, NE, ENE R18 E, ESE, SE R19 SSE R20 S

R21 SSW R22 SW, WSW R23 W

R24 WNW, NW R25 NNW Sub-area(s) Shelter-Sub-area I

M~~4 MM 9I0 1

-in-Place Braidwood Generating Station Evacuation Time Estimate 6-4 KLD Engineering, P.C.

Rev. 0

I

~Sub-areaI Region Description 15 23416 7 8[9 10 11 [121314 [ 15T1 16 Stge Evauaio

-3.l Raiu Evcaete vcatSon idt ie Region Wind Direction Toward:

R26 5-Mile Ring R27 NNW, N R28 NNE, NE, ENE R29 E

R30 ESE, SE R31 SSE R32 SSSW R33 SW, WSW R34 W

R35 WNW, NW R36 2 sector approach R37 2 sector approach Sub-area 1234 5 67 8

9 10 1 12 13 I 14 I 15 16 1-

+/-

  • 1-4-

+/-

I

___ +

4

+

E

-I-f

-i-F--f-+--

I f

I I I I I I I Sub-area(s) Shelter-in-Place I I I

I I

I Braidwood Generating Station Evacuation Time Estimate 6-5 KLD Engineering, P.C.

Rev. 0

Figure 6-1. BWD EPZ Sub-areas Braidwood Generating Station Evacuation Time Estimate 6-6 KLD Engineering, P.C.

Rev. 0

Table 6-2. Evacuation Scenario Definitions Sceari Sesn Day of Wee Tim of Day Wete Speia 1

Summer Midweek Midday Good None 2

Summer Midweek Midday Rain None 3

Summer Weekend Midday Good None 4

Summer Weekend Midday Rain None S

Summer

Midweek, Evening Good None Weekend 6

Winter Midweek Midday Good None 7

Winter Midweek Midday Rain None 8

Winter Midweek Midday Snow None 9

Winter Weekend Midday Good None 10 Winter Weekend Midday Rain None 11 Winter Weekend Midday Snow None 12 Winter

Midweek, Evening Good None Weekend 13 Winter Midweek Midday Good Refueling Outage Single Lane 14 Summer Midweek Midday Good Closure on 1-55 Northbound 1 Winter assumes that school is in session (also applies to spring and autumn). Summer assumes that school is not in session.

Braidwood Generating Station Evacuation Time Estimate 6-7 KLD Engineering, P.C.

Rev. 0

Table 6-3. Percent of Population Groups Evacuating for Various Scenarios 12%79%

96%

65%

21%

0%

10%

100%

100%

3 2%

98%

10%

100%

20%

0%

0%

100%

100%

4 2%

98%

10%

100%

20%

0%

0%

100%

100%

5 2%

98%

10%

15%

20%

0%

0%

100%

40%

6 21%

79%

100%

30%

22%

0%

100%

100%

100%

7 21%

79%

100%

30%

22%

0%

100%

100%

100%

8 21%

79%

100%

30%

22%

0%

100%

100%

100%

9 2%

98%

10%

45%

20%

0%

0%

100%

100%

10 2%

98%

10%

45%

20%

0%

0%

100%

100%

11 2%

98%

10%

45%

20%

0%

0%

100%

100%

12 2%

98%

10%

10%

20%

0%

0%

100%

40%

13 21%

79%

100%

30%

22%

100%

100%

100%

100%

14 21%

79%

96%

65%

21%

0%

10%

100%

100%

Households with Returning Commuters........... Households of EPZ residents who await the return of commuters prior to beginning the evacuation trip.

Households without Returning Commuters...... Households of EPZ residents who do not have commuters or will not await the return of commuters prior to beginning the evacuation trip.

Employees.........................................................

EPZ employees who live outside the EPZ Transients..........................................................

People who are in the EPZ at the time of an accident for recreational or other (non-employment) purposes.

Shadow.............................................................

Residents and employees in the Shadow Region (outside of the EPZ) who will spontaneously decide to relocate during the evacuation. The basis for the values shown is a 20% relocation of shadow residents along with a proportional percentage of shadow employees.

Special Event.....................................................

Additional vehicles in the EPZ due to the identified special event.

School and Transit Buses...................................

Vehicle-equivalents present on the road during evacuation servicing schools, preschools, day camps and transit-dependent people (1 bus is equivalent to 2 passenger vehicles).

External Through Traffic....................................

Traffic on interstates/freeways and major arterial roads at the start of the evacuation. This traffic is stopped by access control 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the evacuation begins.

Braidwood Generating Station 6-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 6-4. Vehicle Estimates by Scenario 1

4,558 17,352 1,602 4,543 5,596 35 20 17,246 50,952 2

4,558 17,352 1,602 4,543 5,596 35 20 17,246 50,952 3

456 21,454 167 6,989 5,254 20 17,246 51,586 4

456 21,454 167 6,989 5,254 20 17,246 51,586 5

456 21,454 167 1,048 5,254 20 6,898 35,297 6

4,558 17,352 1,669 2,097 5,612 354 20 17,246 48,908 7

4,558 17,352 1,669 2,097 5,612 354 20 17,246 48,908 8

4,558 17,352 1,669 2,097 5,612 354 20 17,246 48,908 9

456 21,454 167 3,145 5,254 20 17,246 47,742 10 456 21,454 167 3,145 5,254 20 17,246 47,742 11 456 21,454 167 3,145 5,254 20 17,246 47,742 12 456 21,454 167 699 5,254 20 6,898 34,948 13 4,558 17,352 1,669 2,097 5,612 1,000 354 20 17,246 49,908 14 4,558 17,352 1,602 4,543 5,596 35 20 17,246 50,952 I

Note: Vehicle estimates are for an evacuation of the entire EPZ (Region R03)

Braidwood Generating Station Evacuation Time Estimate 6-9 KLD Engineering, P.C.

Rev. 0