7 GENERAL POPULATION EVACUATION TIME ESTIMATES (ETE)

This section presents the ETE results of the computer analyses using the DYNEV II System described in Appendices B, C and D. These results cover the 38 Evacuation Regions within the BWD EPZ and the 14 Evacuation Scenarios discussed in Section 6.

The ETE for all Evacuation Cases are presented in Table 7-1 and Table 7-2. These tables present the estimated times to clear the indicated population percentages from the Evacuation Regions for all Evacuation Scenarios. The ETE for the 2-mile region in both staged and un-staged regions are presented in Table 7-3 and Table 7-4. Table 7-5 defines the Evacuation Regions considered.

The tabulated values of ETE are obtained from the DYNEV II System outputs which are generated at 5-minute intervals.

7.1 Voluntary Evacuation and Shadow Evacuation "Voluntary evacuees" are people within the EPZ in Sub-areas for which an Advisory to Evacuate has not been issued, yet who elect to evacuate. "Shadow evacuation" is the voluntary outward movement of some people from the Shadow Region (outside the EPZ) for whom no protective action recommendation has been issued. Both voluntary and shadow evacuations are assumed to take place over the same time frame as the evacuation from within the impacted Evacuation Region.

The ETE for the BWD EPZ addresses the issue of voluntary evacuees in the manner shown in Figure 7-1. Within the EPZ, 20 percent of people located in Sub-areas outside of the evacuation region who are not advised to evacuate, are assumed to elect to evacuate. Similarly, it is assumed that 20 percent of those people in the Shadow Region will choose to leave the area.

Figure 7-2 presents the area identified as the Shadow Region. This region extends radially from the plant to cover a region between the EPZ boundary and approximately 15 miles.

The population and number of evacuating vehicles in the Shadow Region were estimated using the same methodology that was used for permanent residents within the EPZ (see Section 3.1). As discussed in Section 3.2, it is estimated that a total of 47,752 people reside in the Shadow Region; 20 percent of them would evacuate. See Table 6-4 for the number of evacuating vehicles from the Shadow Region.

Traffic generated within this Shadow Region, traveling away from the BWD site, has the potential for impeding evacuating vehicles from within the Evacuation Region.

All ETE calculations include this shadow traffic movement.

7.2 Staged Evacuation As defined in NUREG/CR-7002, staged evacuation consists of the following:

1. Sub-areas comprising the 2 mile region are advised to evacuate immediately.
2. Sub-areas comprising regions extending from 2 to 5 miles downwind are advised to shelter in-place while the 2 mile region is cleared.

Braidwood Generating Station 7-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

3. As vehicles evacuate the 2 mile region, people from 2 to 5 miles downwind continue preparation for evacuation while they shelter.
4. The population sheltering in the 2 to 5 mile region is advised to evacuate when approximately 90% of the 2 mile region evacuating traffic crosses the 2 mile region boundary.
5. Non-compliance with the shelter recommendation is the same as the shadow evacuation percentage of 20%.

See Section 5.4.2 for additional information on staged evacuation.

7.3 Patterns of Traffic Congestion during Evacuation Figure 7-3 through Figure 7-7 illustrate the patterns of traffic congestion that arise for the case when the entire EPZ (Region R03) is advised to evacuate during the summer, midweek, midday period under good weather conditions (Scenario 1).

Traffic congestion, as the term is used here, is defined as Level of Service (LOS) F. LOS F is defined as follows (HCM 2010, page 5-5):

The HCM uses LOS F to define operations that have either broken down (i.e., demand exceeds capacity) or have exceeded a specified service measure value, or combination of service measure values, that most users would consider unsatisfactory. However, particularly for planning applications where different alternatives may be compared, analysts may be interested in knowing just how bad the LOS F condition is. Several measures are available to describe individually, or in combination, the severity of a LOS F condition:

e Demand-to-capacity ratios describe the extent to which capacity is exceeded during the analysis period (e.g., by 1%, 15%, etc.);

  • Duration of LOS F describes how long the condition persists (e.g., 15 min, 1 h, 3 h); and e Spatial extent measures describe the areas affected by LOS F conditions. These include measures such as the back of queue, and the identification of the specific intersection approaches or system elements experiencing LOS F conditions.

All highway "links" which experience LOS F are delineated in these figures by a thick red line; all others are lightly indicated. Congestion develops rapidly around concentrations of population and traffic bottlenecks.

Figure 7-3 displays the traffic congestion within the EPZ 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after the Advisory to Evacuate (ATE). At this time, about 90% of transients and employees have begun their evacuation trips, as well as about half of the EPZ residents. Traffic congestion (LOS F) exists at this time along Illinois State Route 53 (IL-53) southbound south of Braceville in Sub-area 10. Evacuees from Godley and Braceville are trying to access Interstate 55 (1-55) in Gardner, leading to the congestion. The 1-55 on ramps at IL-129 and County Route 19 (CR-19) experience congestion as Braidwood Generating Station 7-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

evacuees from Braidwood and employees from Dresden Generating Station attempt to access I-55 northbound. Also, IL-113 is operating at LOS F due to the many evacuees from the Carbon Hill, Coal City and Diamond communities and the numerous traffic control points forcing vehicles westbound on IL-113 and then southbound on IL-47 towards the reception community of Pontiac. The intersection of CR-19 and IU-47 experiences congestion as vehicles are forced south by the traffic control point at the intersection. The population centers of Wilmington, Essex, and Gardner experience congestion as well.

Figure 7-4 displays peak traffic congestion within the EPZ 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 25 minutes after the ATE.

At this time, 98% of transients and employees have begun their evacuation trips, as well as about three-quarters of the EPZ residents. All evacuation routes in Wilmington and Gardner are congested.

1-55 northbound exhibits LOS F due to the heavy volume of vehicles evacuating from Braidwood as well as external traffic along 1-55. IL-113 westbound is congested from the intersection with IL-47 to the intersection with Will Road as a result of heavy volumes and traffic control along the route.

The intersection of 11-47 and CR-19 continues to experience significant congestion. CR-2 in Morris experiences traffic congestion as EPZ evacuees mix with shadow evacuees. Dwight is also congested in the Shadow Region to the southwest of the EPZ.

At 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the ATE, Figure 7-5 shows that traffic congestion within the EPZ is beginning to dissipate on all roads except IL-113. At this time, about 95% of evacuees have begun their evacuation trip and 81% have successfully evacuated the EPZ. Congestion has completely dissipated in Wilmington. CR-15 exhibits the last remnants of congestion in Gardner. The only section of 1-55 experiencing congestion within the EPZ is the segment between CR-19 (Exit 240) and CR-44 (Exit 241) as vehicles from CR-44 merge with 1-55 northbound traffic. At this time, access control points have been established and external through traffic ceases. IL-113 still experiences pronounced congestion and extensive delays.

At 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> after the ATE, as shown in Figure 7-6, IL-113 and IL-47 are the last congested roadways in the EPZ. The 2-mile Region (Sub-areas 1 and 10) has cleared of traffic as the queue along IL-113 has dissipated. All other roads in the EPZ are operating at LOS A. This does not imply that there are no vehicles on the other roads in the EPZ; rather, traffic volume is low and vehicles are experiencing no delay in their evacuation trip.

At this time, nearly all (99.7%)

vehicles have begun their evacuation trips, and 96% of vehicles have successfully evacuated the EPZ.

Finally, at 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 30 minutes after the ATE, Figure 7-7 shows the last of the traffic congestion in the EPZ clearing. IL-47 southbound is the last road to experience LOS F in the EPZ.

All traffic volume (IL-113 westbound) within the 5-mile Region clears 5 minutes later.

Congestion along IL-47 clears 20 minutes later.

7.4 Evacuation Rates Evacuation is a continuous process, as implied by Figure 7-8 through Figure 7-21. These figures indicate the rate at which traffic flows out of the indicated areas for the case of an evacuation of the full EPZ (Region R03) under the indicated conditions. One figure is presented for each scenario considered.

Braidwood Generating Station 7-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

As indicated in Figure 7-8, there is typically a long "tail" to these distributions. Vehicles begin to evacuate an area slowly at first, as people respond to the ATE at different rates. Then traffic demand builds rapidly (slopes of curves increase). When the system becomes congested, traffic exits the EPZ at rates somewhat below capacity until some evacuation routes have cleared. As more routes clear, the aggregate rate of egress slows since many vehicles have already left the EPZ. Towards the end of the process, relatively few evacuation routes service the remaining demand.

This decline in aggregate flow rate, towards the end of the process, is characterized by these curves flattening and gradually becoming horizontal. Ideally, it would be desirable to fully saturate all evacuation routes equally so that all will service traffic near capacity levels and all will clear at the same time. For this ideal situation, all curves would retain the same slope until the end - thus minimizing evacuation time.

In reality, this ideal is generally unattainable reflecting the spatial variation in population density, mobilization rates and in highway capacity over the EPZ.

As discussed in Section 7.3, the major pathway of congestion in the EPZ is IL-113 westbound to IL-47 southbound. This congestion starts in the 2-Mile Region and extends to the EPZ boundary.

This explains why all three curves in Figure 7-8 through Figure 7-21 have the same slope from about 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and 15 minutes after the ATE to 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 30 minutes after the ATE. The slope of this curve is approximately equal to the capacity of IL-113 westbound.

7.5 Evacuation Time Estimate (ETE) Results Table 7-1 and Table 7-2 present the ETE values for all 38 Evacuation Regions and all 14 Evacuation Scenarios. Table 7-3 and Table 7-4 present the ETE values for the 2-Mile Region for both staged and un-staged keyhole regions downwind to 5 miles. The tables are organized as follows:

Tabl Conent ETE represents the elapsed time required for 90 percent of the 7-1 population within a Region, to evacuate from that Region. All Scenarios are considered, as well as Staged Evacuation scenarios.

ETE represents the elapsed time required for 100 percent of the 7-2 population within a Region, to evacuate from that Region.

All Scenarios are considered, as well as Staged Evacuation scenarios.

ETE represents the elapsed time required for 90 percent of the 7-3 population within the 2-mile Region, to evacuate from that Region with both Concurrent and Staged Evacuations.

ETE represents the elapsed time required for 100 percent of the 7-4 population within the 2-mile Region, to evacuate from that Region with both Concurrent and Staged Evacuations.

Braidwood Generating Station 7-4 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

The animation snapshots described above reflect the ETE statistics for the concurrent (un-staged) evacuation scenarios and regions, which are displayed in Figure 7-3 through Figure 7-7.

There is congestion within the 2-mile and 5-mile region for about 21/2 hours. There is congestion beyond the 5-mile region for about 3, hours. This is reflected in the ETE statistics:

The 9 0 th percentile ETE for Region RO0 (2-mile region) range from 1:55 (hr:min) to 2:15 for all scenarios except the roadway closure.

The 9 0 th percentile ETE for Region R02 (5-mile region) are up to 20 minutes longer than the ETE for Region R01 for all scenarios except the roadway closure and range between 2:10 (hr:min) to 2:35 for all scenarios except the roadway closure.

The 9 0 th percentile ETE for Region R03 (full EPZ) are up to 15 minutes longer than the ETE for Region R02 due to the congestion along IL-113 and IL-47. The ETE range from 2:15 to 2:50 for all scenarios except the roadway closure.

The 1 0 0 th percentile ETE for all regions range from 3:30 to 4:25 for non-snow scenarios and between 4:35 and 5:00 for snow scenarios. This reflects the time needed to clear congestion along IL-113 westbound and IL-47 southbound.

Comparison of Scenarios 6 and 13 in Table 7-1 indicates that the Special Event - a refueling outage at BWD - has no impact on the 90th or 100th percentile ETE.

The 1,000 additional employees present for an outage mobilize quickly (see Figure 5-4) and can route either direction along IL-53 to access 1-55 and avoid the congestion along IL-113 westbound and IL-47 southbound.

Comparison of Scenarios 1 and 14 in Table 7-1 indicates that the roadway closure - Interstate-55 northbound from the intersection of W Kennedy Rd/E Reed Rd (Exit 233) to the intersection with Interstate-80 (Exit 250) (see Section 2.2, item 7) - increases the 9 0 th and 1 0 0 th percentile ETE by at most 40 minutes and 30 minutes, respectively - a significant change. As discussed in Section 7.3, evacuees from the plant and from Braidwood use IL-113, IL-129 and CR-19 to access 1-55 and evacuate the EPZ. The closure of a lane on 1-55 northbound diminishes the capacity of the roadway, causing additional delay (and prolonged ETE) for vehicles trying to access 1-55 via ramps from IL-113, IL-129 and CR-19.

The results of the roadway impact scenario indicate that events such as adverse weather or traffic accidents which close a lane on a major evacuation route, could impact ETE. State and local police could consider traffic management tactics such as using the shoulder of the roadway as a travel lane or re-routing of traffic along other evacuation routes to avoid overwhelming any of the major evacuation routes. All efforts should be made to remove the blockage, particularly within the first 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of the evacuation when most people begin their evacuation trip.

Braidwood Generating Station 7-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

7.6 Staged Evacuation Results Table 7-3 and Table 7-4 present a comparison of the ETE compiled for the concurrent (un-staged) and staged evacuation studies. Note that Regions R26 through R38 are the same geographic areas as Regions R02 and R04 through R15, respectively. The times shown in Table 7-3 and Table 7-4 are when the 2-mile region is 90% clear and 100% clear, respectively.

The objective of a staged evacuation strategy is to ensure the ETE for the 2-mile region is not impacted when evacuating people beyond 2 miles from the plant. As shown in Table 7-3 and Table 7-4, the ETE for the 2-mile region is unchanged when a staged evacuation is implemented.

To determine the effect of staged evacuation on residents beyond the 2-mile region, Regions R02 and R04 through R15 are compared to Regions R26 through R38, respectively, in Table 7-1.

The ETE for each region increases when staging evacuation with some regions increasing by up to 15 minutes. As shown in Figure 5-5, staging the evacuation causes a significant "spike" (sharp increase) in mobilization (trip-generation rate) of evacuating vehicles: nearly 80 percent of the evacuating vehicles between 2 and 5 miles who have sheltered in place while residents within 2 miles evacuated, begin their evacuation trip over a 15 minute timeframe. This spike oversaturates evacuation routes, increasing traffic congestion and prolongs ETE.

In summary, the staged evacuation protective action strategy provides no benefit to evacuees from within the 2-mile region and adversely impacts many evacuees located beyond 2 miles from BWD. Staged evacuation is not recommended.

7.7 Guidance on Using ETE Tables The user first determines the percentile of population for which the ETE is sought (The NRC guidance calls for the 9 0 th percentile). The applicable value of ETE within the chosen Table may then be identified using the following procedure:

1. Identify the applicable Scenario:

Season

" Summer

" Winter (also Autumn and Spring)

Day of Week Midweek

" Weekend

" Time of Day Midday Evening Weather Condition Good Weather Rain Snow Braidwood Generating Station 7-6 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Special Event Refueling Outage Road Closure - Single lane closed on 1-55 northbound Evacuation Staging No, Staged Evacuation is not considered Yes, Staged Evacuation is considered While these Scenarios are designed, in aggregate, to represent conditions throughout the year, some further clarification is warranted:

0 The conditions of a summer evening (either midweek or weekend) and rain are not explicitly identified in the Tables. For these conditions, Scenarios (2) and (4) apply.

The conditions of a winter evening (either midweek or weekend) and rain are not explicitly identified in the Tables. For these conditions, Scenarios (7) and (10) for rain apply.

The conditions of a winter evening (either midweek or weekend) and snow are not explicitly identified in the Tables. For these conditions, Scenarios (8) and (11) for snow apply.

0 The seasons are defined as follows:

" Summer assumes that public schools are not in session.

" Winter (includes Spring and Autumn) considers that public schools are in session.

a Time of Day: Midday implies the time over which most commuters are at work or are travelling to/from work.

2. With the desired percentile ETE and Scenario identified, now identify the Evacuation Region 0

Determine the projected azimuth direction of the plume (coincident with the wind direction). This direction is expressed in terms of compass orientation: towards N, NNE, NE,...

Determine the distance that the Evacuation Region will extend from the nuclear power plant. The applicable distances and their associated candidate Regions are given below:

0 2 Miles (Region R01) 0 To 5 Miles (Regions R02, R04 through R15) 0 To EPZ Boundary (Regions R03, R16 through R25)

Enter Table 7-5 and identify the applicable group of candidate Regions based on the distance that the selected Region extends from the plant. Select the Evacuation Region identifier in that row, based on the azimuth direction of the plume, from the first column of the Table.

Braidwood Generating Station Evacuation Time Estimate 7-7 KLD Engineering, P.C.

Rev. 0

3. Determine the ETE Table based on the percentile selected.

Then, for the Scenario identified in Step I and the Region identified in Step 2, proceed as follows:

The columns of Table 7-1 through Table 7-4 are labeled with the Scenario numbers.

Identify the proper column in the selected Table using the Scenario number defined in Step 1.

Identify the row in the table that provides ETE values for the Region identified in Step 2.

The unique data cell defined by the column and row so determined contains the desired value of ETE expressed in Hours:Minutes.

Example It is desired to identify the ETE for the following conditions:

Sunday, August 10th at 4:00 AM.

It is raining.

Wind direction is toward the northeast (NE).

Wind speed is such that the distance to be evacuated is judged to be a 5-mile radius and downwind to 10 miles (to EPZ boundary).

The desired ETE is that value needed to evacuate 90 percent of the population from within the impacted Region.

A staged evacuation is not desired.

Table 7-1 is applicable because the 90th percentile ETE is desired. Proceed as follows:

1. Identify the Scenario as summer, weekend, evening and raining. Entering Table 7-1, it is seen that there is no match for these descriptors.

However, the clarification given above assigns this combination of circumstances to Scenario 4.

2. Enter Table 7-5 and locate the Region described as "Evacuate 5-Mile Radius and Downwind to the EPZ Boundary" for wind direction toward the NE and read Region R17.
3. Enter Table 7-1 to locate the data cell containing the value of ETE for Scenario 4 and Region R17. This data cell is in column (4) and in the row for Region R17; it contains the ETE value of 2:20.

Braidwood Generating Station 7-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 7-1. Time to Clear the Indicated Area of 90 Percent of the Affected Population Summer Summer Summer Winter Winter Winter Winter Summer

________M____

nirwek 2-ieRgoni-ieReindnwEZeek Midweek Weekend e

Midweek Weekend Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Goo Rai Good Rai Go God Ri Snw od Rain Snow Good Refueling Roadwa Rgo Weather od Ri Weather Go Ran Weather God Weather Goo RIn So Weather Weather Outage Impact Entire 2-Mile Region, 5-Mile Region, and EPZ RO1 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R02 2:10 2:20 1:55 2:20 2:15 2:10 2:0 2:15 2:00 2:00 2:10 1:55 2:00 2:50 R03 2:20 2:30 2:155 2:00 1:55 2:00 2:50 2:50 2:15 2:25 2:40 2:20 2:20 2:55 2-Mile Region and Keyhole to 5 Miles R04 2:10 2:15 2:05 2:15 2:10 2:10 2:15 2:30 2:05 2:15 2:25 2:10 2:10 2:45 R05 2:00 2:05 2:00 2:05 1:55 2:05 2:05 2:20 2:00 2:00 2:20 1:55 2:05 2:30 R06 2:00 2:05 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R07 2:00 2:00 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R08 2:00 2:05 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R09 2:00 2:00 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R10 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:25 Rll 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R12 2:15 2:20 2:10 2:15 2:20 2:15 2:20 2:35 2:10 2:15 2:30 2:20 2:15 2:40 Site Specific Regions R13 2:00 2:00 1:55 2:00 1:55 2:00 2:05 2:15 2:00 2:00 2:10 1:55 2:00 2:15 R14 2:10 2:15 2:05 2:10 2:05 2:10 2:15 2:30 2:05 2:10 2:25 2:10 2:10 2:30 R15 2:00 2:05 2:05 2:05 1:55 2:05 2:05 2:20 2:00 2:05 2:20 1:55 2:05 2:30 5-Mile Region and Keyhole to EPZ Boundary R16 2:10 2:20 2:10 2:20 2:10 2:10 2:15 2:30 2:10 2:15 2:30 2:10 2:10 2:45 R17 2:10 2:20 2:10 2:20 2:10 2:10 2:15 2:35 2:05 2:15 2:30 2:10 2:10 2:45 RIB 2:10 2:15 2:10 2:15 2:10 2:15 2:15 2:35 2:10 2:15 2:25 2:10 2:15 2:45 R19 2:10 2:15 2:10 2:15 2:15 2:15 2:20 2:35 2:10 2:15 2:30 2:15 2:15 2:50 R20 2:15 2:20 2:10 2:15 2:15 2:15 2:20 2:35 2:10 2:15 2:30 2:15 2:15 2:50 R21 2:30 2:40 2:25 2:35 2:40 2:35 2:50 3:15 2:30 2:40 3:05 2:40 2:35 3:10 R22 2:25 2:30 2:20 2:25 2:35 2:30 2:35 3:00 2:25 2:30 2:50 2:35 2:30 3:05 R23 2:25 2:30 2:20 2:25 2:30 2:30 2:35 3:00 2:20 2:30 2:45 2:30 2:30 3:05 R24 2:20 2:30 2:15 2:20 2:25 2:25 2:30 2:55 2:20 2:25 2:45 2:30 2:25 3:00 R25 2:15 2:25 2:15 2:25 2:20 2:20 2:25 2:45 2:15 2:20 2:35 2:20 2:20 2:55 Braidwood Generating Station Evacuation Time Estimate 7-9 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Midweek Weekend Weekend Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Good Good Rain S

Good Rain Snow Good Refueling Roadway Weather Weather Rain Weather Weather n

Weather I Weather Outage Impact Staged Evacuation Mile Region and Keyhole to 5 Miles R26 2:20 2:20 2:15 2:20 2:25 2:20 2:20 2:40 2:20 2:20 2:35 2:25 2:20 3:00 R27 2:15 2:20 2:15 2:15 2:20 2:20 2:20 2:35 2:15 2:15 2:30 2:20 2:20 2:50 R28 2:10 2:10 2:05 2:10 2:05 2:10 2:10 2:25 2:05 2:10 2:20 2:05 2:10 2:30 R29 2:05 2:05 2:00 2:05 2:05 2:05 2:10 2:20 2:05 2:05 2:20 2:05 2:05 2:15 R30 2:10 2:10 2:05 2:05 2:10 2:10 2:10 2:25 2:10 2:10 2:20 2:10 2:10 2:15 R31 2:05 2:10 2:05 2:05 2:05 2:10 2:10 2:25 2:05 2:10 2:20 2:05 2:10 2:20 R32 2:10 2:10 2:05 2:10 2:10 2:10 2:10 2:25 2:10 2:10 2:25 2:10 2:10 2:20 R33 2:10 2:10 2:05 2:10 2:10 2:10 2:10 2:25 2:10 2:10 2:20 2:10 2:10 2:25 R34 2:05 2:10 2:05 2:05 2:05 2:05 2:10 2:20 2:05 2:05 2:15 2:05 2:05 2:20 R35 2:15 2:20 2:15 2:15 2:20 2:20 2:20 2:35 2:15 2:20 2:35 2:25 2:20 2:45 Staged Evacuation - Site Specific Regions R36 2:10 2:10 2:05 2:05 2:05 2:10 2:10 2:25 2:05 2:10 2:20 2:10 2:10 2:20 R37 2:15 2:20 2:15 2:15 2:20 2:15 2:20 2:35 2:15 2:15 2:30 2:20 2:15 2:35 R38 2:05 2:10 2:05 2:10 2:05 2:10 2:10 2:20 2:05 2:05 2:20 2:05 2:10 2:35 Braidwood Generating Station Evacuation Time Estimate 7-10 KLD Engineering, P.C.

Rev. 0

Table 7-2. Time to Clear the indicated Area of 100 Percent of the Affected Population Weather Weather Weather Weather Weatherer Witr ume Midweek_

Weekend M__

_Etr

-ileee Rgo,5MilweRegin anden MiPee Midweek Midweek___

Enie2-Mile Region, andeyhle tegon 5

n Mies R01 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R02 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R03

3 3:

35:2 3:35 3:35 3:350 3:35 3:35 4:35 3:350 3:35 4:35 3:350 3:35 3:35 R04 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R09 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R06 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R07 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R08 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R09___

3:35_

3:35 Site Speifi Region 3:5_:5_:5_:3_:3_:3_33_

3333 R10 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 RI4 3:35 3:35 3:35 3:35 j3:35 3:35 3:35 4:35 f3:35 3:35 4:35 3:35 3:35 3:35 R12 3:35 3:35 3:35 3:35 j 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 5-Mile t Secfi RegionsadKyoet P

onay___

R13 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:45 R14 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:45 R15 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:40 R16 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:40 R17 3:40 3:40 3:40 3:40 3:40 3:40 3:40 4:40 3:40 3:40 4:40 3:40 3:40 3:40 RIB 3:55 34:1 3:50 34:0 3:50 3:40 34:0 4:40 3:50 34:0 4:40 3:40 3:55 3420 R22 3:55 4:20 3:50 4:15 3:50 3:55 4:20 5:00 3:50 4:15 4:50 3:50 3:55 4:25 R23 3:55 4:20 3:55 4:15 3:50 4:00 4:25 5:00 3:50 4:20 4:50 3:50 4:00 4:25 R24 3:50 4:10 3:45 4:10 3:45 3:50 4:15 4:55 3:45 4:10 4:45 3:45 3:50 4:15 R25 3:40 4:00 3:40 4:00 3:40 3:40 4:05 4:40 3:40 3:55 4:40 3:40 3:40 4:05 Braidwood Generating Station Evacuation Time Estimate 7-11 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend MdekMidweek Weekend MdekMidweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Rain Good Good Rain Snow Goh Rain Snow Weather eOutag Roac Weather Weather I

Weather Weather Weather Weather Outage Impact Staged Evacuation Mile Region and Keyhole to 5 Miles R26 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:50 R27 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R28 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 R29 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R30 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R31 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R32 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R33 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R34 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R35 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:50 Staged Evacuation - Site Specific Regions R36 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R37 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:35 R38 3:35 3:35 3:35 3:35 3:35 3:35 3:35 4:35 3:35 3:35 4:35 3:35 3:35 3:40 742 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate 7-12 KLD Engineering, P.C.

Rev. 0

Table 7-3. Time to Clear 90 Percent of the 2-Mile Area within the Indicated Region Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend MidU-ed Midweek Weekend 5-Mile Midweek Midweek Weekend Weekend Scnrio1)0 (201:52

0011:4) 5512:0512:0512:1512:002:02:111:5512:0512:2014 Midday Midday Evening Midday Midday Evening Midday Midday Rein Go an Go an Go od Rin So Good Rain Snow Good Refueling Roadway Rgo WeatherG°d Ri WeatherG°d Ri WeatherG° WeatherG°° I Ri SnwWeather Weather Outage Impact Un-staged Evacuation Mile and S-Mile Region R02 2:00 2:05 1:55 2:00 1:55 2:05 1 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Un-staged Evacuation Mile Ring and Keyhole to S-Miles R04 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 ROS 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R06 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R07 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R08 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R09 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 RIO 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R11 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R12 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Un-staged Evacuation - Site Specific Regions R13 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R14 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R15 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Staged Evacuation - S-Mile Region R26 2:00 2:05 [

1:55 2:00 1:55 2:05 1 2:05 1 2:15 1 2:00 2:00 2:10 1:55 2:05 2:20 Staged Evacuation Mile Ring and Keyhole to 5 Miles R27 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R28 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R29 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R30 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R31 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R32 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R33 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R34 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R35 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Braidwood Generating Station Evacuation Time Estimate 7-13 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Midweek Weekend Weekend Midweek Midweek Weewkend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good n

Good Good Rain Good Rain Snow Good Refueling Roadway Region Weather Weather Rain Weather Weather I

now Weather Weather Outage Impact Staged Evacuation - Site Specific Regions R36 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R37 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 R38 2:00 2:05 1:55 2:00 1:55 2:05 2:05 2:15 2:00 2:00 2:10 1:55 2:05 2:20 Braidwood Generating Station Evacuation Time Estimate 7-14 KLD Engineering, P.C.

Rev. 0

Table 7-4. Time to Clear 100 Percent of the 2-Mile Area within the Indicated Region Summer Summer Summer Winter Winter Winter Winter Summer Midweek Weekend MidU-ed Midweek Weekend 5-Mile Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Ran Good Rain Good Good Rain Snow Weahe i

Sn w

eath efelin Impadwa Weather Ran Weather Weather Weather I IWaethr Outage Ipc Un-staged Evacuation Mile and 5-Mile Region R01 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R02 J3:35 3:35 J3:30 j 3:30 L3:30 j

3:35 1 3:35 1 4:35 1 3:30 3:30 4:30 j3:30 J3:3 3:35 Un-staged Evacuation Mile Ring and Keyhole to 5-Miles R04 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R05 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R06 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R07 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R08 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R09 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 RiO 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R11 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R12 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Un-staged Evacuation - Site Specific Regions R13 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R14 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R15 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Staged Evacuation Mile Region R26 3:35 3:35 3:30 3:30 3:30

[

3:35 1 3:35 4:35 1

3:30 3:30 4:30 3:30 3:35 3:35 Staged Evacuation Mile Ring and Keyhole to 5 Miles R27 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R28 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R29 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R30 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R31 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R32 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R33 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R34 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R35 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Braidwood Generating Station Evacuation Time Estimate 7-15 KLD Engineering, P.C.

Rev. 0

Summer Summer Summer Winter Winter Winter Winter Summer Midweek Midweek Midweek Weekend Weekend Midweek Weekend Weekend Midweek Midweek Weekend Weekend Midday Midday Evening Midday Midday Evening Midday Midday Region Good Rain Good Good Good Rain S

Good Rain Snow Good Refueling Roadway Weather Weather Rain Weather Weather Weather Weather Outage Impact Staged Evacuation - Site Specific Regions R36 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R37 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 R38 3:35 3:35 3:30 3:30 3:30 3:35 3:35 4:35 3:30 3:30 4:30 3:30 3:35 3:35 Braidwood Generating Station Evacuation Time Estimate 7-16 KLD Engineering, P.C.

7-16 KLD Engineering, P.C.

Rev. 0

Table 7-5. Description of Evacuation Regions Region R16 R17 R18 R19 R20 R21 R22 R23 R24 R25 Sub-area Wind Direction Toward:

1 2

3 4

5 8

9 10 1

12 13 1 14 15 N

NNE, NE, ENE E, ESE, SE SSE S

SSW SW, WSW W

WNW, NW NNW Sub-area(s) Shelter-in-Place Braidwood Generating Station Evacuation Time Estimate 7-17 KLD Engineering, P.C.

Rev. 0

t Sub-area ReinIDescription 1

0 1

2113 I14 1S 16 R26 I5-Mile Ring R27

INNW, N

R28 I

NNE, NE, ENE R29 E

R30 ESE, SE R31 SSE R32 SSSW R33 SW, WSW R34 W

R35

IWNW, NW R36 I

2 sector approach R37 2 sector approach R38 2 sector approach

~Sub-area(s)

Shelter-in -Place Braidwood Generating Station 7-18 KILD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure 7-1. Voluntary Evacuation Methodology Braidwood Generating Station Evacuation Time Estimate 7-19 KLD Engineering, P.C.

Rev. 0

Mi0e p____

io~t

~

Frank for see-

-N

-M.

~R-.~".

Manhattan flnai§:f?

El ood m

\\-

Moms>

Tllds Sbrea. 4 baa Seneca k-5 Sub-area:2 y erton Sub 8area:-7 icit Mazo I

a r ea.

a r:G o3le yI Verona Sub-areA: 12 ill ub-ea: 1

/

Kinsman U Ironer ua:

Bourbonnais Brooklyn Sub-area: 61

//

(4) u area:

Sub-area:

Sub-area: 9 /Limestone Sub-area: 16 D&jnsi-to55 Ka eke Legend

//ýwqgt a

  • 3WD 8z S

r Buckingham Hrsc;er Irwin 2, 5, 10, 15 Mile Rings Shadow Region Campus S*o*ont m

'w.'I'gEM~ti5.,.mioChebanse i

Figure 7-2. BWD Shadow Region Braidwood Generating Station 72 Evacuation Time Estimate KLD Engineering, P.C.

Rev. 0

3swgo Bolingbrook i'

r emontle Palo$,

Congestion Patterns at 01:00 w

  • in
abo, P.rk A o*k I [2j/

Glen I

'{or~and LO-PrattviHl C

Plubar a:

in ynl

/Lcprr D

0 S

atvia hore wak w

t F

-Plttfle Mokenai SSubo areal 10"R1Sk b-area: 13

-=Sub-area:

12 4ir

,ua Lisbon

  1. bonnaix X" IInsmanrakfr C( -ty Sub ar a4

)

an ata Sub-area:

16S b ý-area -

1 4

if (mid,~'S rtimstnen Legend BWD go Sub-a 2,5,1 shado Hers erIrwin Kankakee

[0, 15 Mile Rings Wte 4/1~2i

Kok, 6/2014u Kqnik~ik,'(

_oc Chebanse ow Region Ccpynght; ESR1 Fiswnp Cei Caberyl Ford C 0

10 KID G--~ecg I~o Milesio I

I Miles Figure 7-3. Congestion Patterns at 1 Hour after the Advisory to Evacuate Braidwood Generating Station Evacuation Time Estimate 7-21 KLD Engineering, P.C.

Rev. 0

Congestion Patterns at 01:25 Blnbook erlr; Park

~wnCollC ntyt OSYorkville W

i Romeo We A

kGlen c

C E

30 F

PlattvillehM 2.~e.

5.

10 1

MleRig 4

E Lisbon tan erennx wooGera S2 Engn E

Time-Earimat Rv0 Su-ra 25-ubaea' Carboe" Diaffio.akewood 47 ub-area: I shores r~

~

S area:WOO 2

=*~~~~~

I.

L--oo-Mzdna

  • insman 41%=

\\ubaa:1J Sub-area:*

_-i(i)- -/

"2 iZubon Leged

=,

i

"*t HesC,Irwi Kanake Essex.,

m I

" - 315 p

S u b -a re a B o n fiepl d-t:£S I a m a D t KI D En-irea 16 K

ub-aonGe erato 1

14ilesb-rea Evacuation-1 Tim UnimonRe.

Congestion Patterns at 02:00sw r

klo, rook Glen BD4D C

PI-aea inil Creb-re:st D

I--

Ciro*

I

\\

E 3

F*I

-}u-lartiea:l Su orwo 0Mk

__(k L_q Libo

-Lie sto ne _(x Le~ed w-am Iwin rankfort BWDManhattan Sub....

/u,,kk~eC Ka uk*",u,,C.

rhaanse 2,

5 10,5 Mie Rngs

'!"CE-L2]*SaowRao pwgtelg

[*

Dt Briwo enerain Stton 7-23ea 5L niernP Evacuation~'

TieEsiat evn

io, Paterns at 03:00 Fswego 0ongbrook Pa o LOSYorkville IO Romeo i/fe me B

30-Plarvillek S-oe

=

ki 2L.01 i sbonng k oko k-----

Cheranseor Ken a o un

-i 0

5 10 Kisbo n

2n....

,Iy.n bMi Braidwood Genrn SMa n

e P.C.

Evaanutoin E aeooR 11

,Sub-are' a

14 P*1fr s~r'_

l

\\

=

S nea-Co baral" 5

\\Sbae'1 Sub-area:1 2

.iL.o/gf

'S r t

  • erubarea a

2 5*;baea Sub-a u-aeaea/I

'7 carborl ron

/

bon /

-M I

rde Braiwoo Genrain onto

-4KDEniernPC Evacuation7 TiimEsimaeonve

at0:0swego Bolingbrook 1

emont n

Palo Congestion Patterns at 03:3030 Park LOS York ville 7>*

Aok leRomeo ile Hbmer

-A Foo 4D i

Glen ONno I B 3

V5an t ctCrbpPar C

Plain field /

rst

-- S b-rew:'

FU~r platvi°a Moken 52oc oortda L

isbo f uoubon Figue77CogsinPternsdt 3Hour an 30 Miue after th dioyoEaut Braidwood5Gene Raings Saio 72KLEnieernPC Eaai Time Estimate Knkou Rhev.n 0 Baidwod Geeratin Staton 7-2 KLDanhattnernP.

EvacutionTimeEstiate ev.

Evacuation Time Estimates Summer, Midweek, Midday, Good (Scenario 1) Mile Region 5-Mile Region Entire EPZ 0

90%

0 100%

'U LU

'U 45 40 35 30

% 25 o 20 15 10 5

0

.000ý 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-8. Evacuation Time Estimates - Scenario I for Region R03 Evacuation Time Estimates Summer, Midweek, Midday, Rain (Scenario 2) 2-Mile Region 5-Mile Region Entire EPZ 90%

0 100%

'U" w

45 40 35 30 25 20 15 10 5

0

-w 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-9. Evacuation Time Estimates - Scenario 2 for Region R03 Braidwood Generating Station Evacuation Time Estimate 7-26 KLD Engineering, P.C.

Rev. 0

Evacuation Time Estimates Summer, Weekend, Midday, Good (Scenario 3) Mile Region Mile Region

ýEntire EPZ 0 90%

0 100%

AP 45 40 tf 35

.r-30 r 25 U.' o 20

>t 15

>~

10 5

0

-w I

I 1

II77 1V 0

30 30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-10. Evacuation Time Estimates - Scenario 3 for Region R03 Evacuation Time Estimates Summer, Weekend, Midday, Rain (Scenario 4) Mile Region Mile Region

-Entire EPZ 0

90%

0 100%

U Ui In 0

C (U

In 0

I-45 40 35 30 25 20 15 10 5

0 30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-11. Evacuation Time Estimates - Scenario 4 for Region R03 7-27 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate 7-27 KLD Engineering, P.C.

Rev. 0

Evacuation Time Estimates Summer, Midweek, Weekend, Evening, Good (Scenario 5) Mile Region Mile Region

-Entire EPZ 90%

0 100%

45 40 tw 35 C

m 7 30 UJ

_ 20 u -15 10 5

0 0

[

[

AM

loop, qW 30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-12. Evacuation Time Estimates - Scenario 5 for Region R03 Evacuation Time Estimates Winter, Midweek, Midday, Good (Scenario 6) 2-Mile Region Mile Region

-Entire EPZ 0 90%

0 100%

M Uj

E C

0 45 40 35 30 25 20 15 10 5

0 I

0 30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-13. Evacuation Time Estimates - Scenario 6 for Region R03 Braidwood Generating Station Evacuation Time Estimate 7-28 KLD Engineering, P.C.

Rev. 0

Evacuation Time Estimates Winter, Midweek, Midday, Rain (Scenario 7) 2-Mile Region 5-Mile Region Entire EPZ 0 90%

0 100%

LU 0).

45 40 35 30 25 20 15 10 5

0 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-14. Evacuation Time Estimates - Scenario 7 for Region R03 Evacuation Time Estimates Winter, Midweek, Midday, Snow (Scenario 8) 2-Mile Region 5-Mile Region Entire EPZ 0 90%

0 100%

'U Ui 45 40 35 2

30 N 25 0 20 15 10 5

0 do 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-15. Evacuation Time Estimates - Scenario 8 for Region R03 7-29 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate 7-29 KLD Engineering, P.C.

Rev. 0

Evacuation Time Estimates Winter, Weekend, Midday, Good (Scenario 9) 2-Mile Region 5-Mile Region Entire EPZ 0 90%

0 100%

LU M 0

45 40 35 30 25 20 15 10 5

0

__ -r,

ý I _

1 -0 Adbooý Ode-Ogw 00, 100 ý_.,O 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-16. Evacuation Time Estimates - Scenario 9 for Region R03 Evacuation Time Estimates Winter, Weekend, Midday, Rain (Scenario 10) 2-Mile Region 5-Mile Region Entire EPZ 90%

0 100%

4-.

U LU U

0 45 40 35 30 25 20 15 10 5

0 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-17. Evacuation Time Estimates - Scenario 10 for Region R03 7-30 KID Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate 7-30 KLD Engineering, P.C.

Rev. 0

Evacuation Time Estimates Winter, Weekend, Midday, Snow (Scenario 11) Mile Region Mile Region

-Entire EPZ

  • 90%

0 100%

45 40 UO 35 4..m 30 M 25 6 20

>I 10 5

0 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-18. Evacuation Time Estimates - Scenario 11 for Region R03 Evacuation Time Estimates Winter, Midweek, Weekend, Evening, Good (Scenario 12) 2-Mile Region 5-Mile Region

-Entire EPZ 0 90%

100%

an C

(U U(U w

Ina, U

a, In 0

45 40 35 30 25 20 15 10 5

0 AdEmp-0 30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-19. Evacuation Time Estimates - Scenario 12 for Region R03 7-31 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate 7-31 KLD Engineering, P.C.

Rev. 0 I

Evacuation Time Estimates Winter, Midweek, Midday, Good, Special Event (Scenario 13) 2-Mile Region 5-Mile Region Entire EPZ 0 90%

0 100%

4-M Ui M

0 45 40 35 30 25 20 15 10 5

0 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-20. Evacuation Time Estimates - Scenario 13 for Region R03 Evacuation Time Estimates Summer, Midweek, Midday, Good, Roadway Impact (Scenario 14) 2-Mile Region 5-Mile Region Entire EPZ 0 90%

0 100%

(U (U

0 45 40 35 30 25 20 15 10 5

0 0

30 60 90 120 150 180 210 240 Elapsed Time After Evacuation Recommendation (min) 270 300 Figure 7-21. Evacuation Time Estimates - Scenario 14 for Region R03 Braidwood Generating Station Evacuation Time Estimate 7-32 KLD Engineering, P.C.

Rev. 0

8 TRANSIT-DEPENDENT AND SPECIAL FACILITY EVACUATION TIME ESTIMATES This section details the analyses applied and the results obtained in the form of evacuation time estimates for transit vehicles. The demand for transit service reflects the needs of three population groups: (1) residents with no vehicles available; (2) residents of special facilities such as schools, pre-schools, day camps, and medical facilities (3) homebound special needs population.

These transit vehicles mix with the general evacuation traffic that is comprised mostly of "passenger cars" (pc's). The presence of each transit vehicle in the evacuating traffic stream is represented within the modeling paradigm described in Appendix D as equivalent to two pc's.

This equivalence factor represents the longer size and more sluggish operating characteristics of a transit vehicle, relative to those of a pc.

Transit vehicles must be mobilized in preparation for their respective evacuation missions.

Specifically:

Bus drivers must be alerted They must travel to the bus depot They must be briefed there and assigned to a route or facility These activities consume time.

It is estimated that bus mobilization time will average approximately 90 minutes for schools buses and 120 minutes for transit dependent buses extending from the Advisory to Evacuate, to the time when buses first arrive at the facility to be evacuated.

During this mobilization period, other mobilization activities are taking place. One of these is the action taken by parents, neighbors, relatives and friends to pick up children from school prior to the arrival of buses, so that they may join their families. Virtually all studies of evacuations have concluded that this "bonding" process of uniting families is universally prevalent during emergencies and should be anticipated in the planning process. The current public information disseminated to residents of the BWD EPZ indicates that schoolchildren will be evacuated to reception centers, and that parents should pick schoolchildren up at the reception centers.

As discussed in Section 2, this study assumes a fast breaking general emergency. Therefore, children are evacuated to reception centers. Picking up children at school could add to traffic congestion at the schools, delaying the departure of the buses evacuating schoolchildren, which may have to return in a subsequent "wave" to the EPZ to evacuate the transit-dependent population. This report provides estimates of buses under the assumption that no children will be picked up by their parents (in accordance with NUREG/CR-7002), to present an upper bound estimate of buses required. This study assumes that pre-schools and day camps are also evacuated to reception centers and parents will pick up these children at the reception centers.

Braidwood Generating Station 8-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

The procedure for computing transit-dependent ETE is to:

Estimate demand for transit service Estimate time to perform all transit functions Estimate route travel times to the EPZ boundary and to the reception centers 8.1 Transit Dependent People Demand Estimate The telephone survey (see Appendix F) results were used to estimate the portion of the population requiring transit service based on the percentage of households with no vehicle available.

Table 8-1 presents estimates of transit-dependent people. Note:

Estimates of persons requiring transit vehicles include schoolchildren.

For those evacuation scenarios where children are at school when an evacuation is ordered, separate transportation is provided for the schoolchildren. The actual need for transit vehicles by residents is thereby less than the given estimates.

However, estimates of transit vehicles are not reduced when schools are in session.

It is reasonable and appropriate to consider that many transit-dependent persons will evacuate by ride-sharing with neighbors, friends or family. For example, nearly 80 percent of those who evacuated from Mississauga, Ontario who did not use their own cars, shared a ride with neighbors or friends (IES, 1981). Other documents report that approximately 70 percent of transit dependent persons were evacuated via ride sharing. We will adopt a conservative estimate that 50 percent of transit dependent persons will ride share, in accordance with NUREG/CR-7002.

The estimated number of bus trips needed to service transit-dependent persons is based on an estimate of average bus occupancy of 30 persons at the conclusion of the bus run. Transit vehicle seating capacities typically equal or exceed 60 children on average (roughly equivalent to 40 adults). If transit vehicle evacuees are two thirds adults and one third children, then the number of "adult seats" taken by 30 persons is 20 + (2/3 xl0) = 27. On this basis, the average load factor anticipated is (27/40) x 100 = 68 percent. Thus, if the actual demand for service exceeds the estimates of Table 8-1 by 50 percent, the demand for service can still be accommodated by the available bus seating capacity.

[20+ (

Xo)0

- 40 x 1.5 = 1.00 Braidwood Generating Station 8-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 8-1 indicates that transportation must be provided for 275 people. Therefore, a total of 10 bus runs are required to transport this population to reception centers.

To illustrate this estimation procedure, we calculate the number of persons, P, requiring public transit or ride-share, and the number of buses, B, required for the BWD EPZ:

P = (EPZ Population - Average HH Size of EPZ) x % of HH with 0 Vehicles x Average HH Size of HH with 0 Vehicles P = (39,762 + 2.40) x 3.1% x 1.07 = 550 B = (0.5 x P) + 30 = 10 According to the telephone survey results, 3.1% of households do not have access to a vehicle (Figure F-2); there are 1.07 people per house - on average - in households with no vehicles available.

8.2 School, Pre-School and Day Camp Population-Transit Demand Table 8-2 presents the school, pre-school, and day camp population and transportation requirements for the direct evacuation of all facilities within the EPZ for the 2012 school year.

The column in Table 8-2 entitled "Buses Required" specifies the number of buses required for each school under the following set of assumptions and estimates:

No students will be picked up by their parents prior to the arrival of the buses.

While many high school students commute to school using private automobiles (as discussed in Section 2.4 of NUREG/CR-7002), the estimate of buses required for school evacuation do not consider the use of these private vehicles.

Bus capacity, expressed in students per bus, is set to 70 for primary schools and pre-schools and 50 for day camps, middle and high schools.

Those staff members who do not accompany the students will evacuate in their private vehicles.

No allowance is made for student absenteeism, typically 3 percent daily.

It is recommended that the counties in the EPZ introduce procedures whereby the schools are contacted prior to the dispatch of buses from the depot, to ascertain the current estimate of students to be evacuated.

In this way, the number of buses dispatched to the schools will reflect the actual number needed. The need for buses would be reduced by any high school students who have evacuated using private automobiles (if permitted by school authorities).

Those buses originally allocated to evacuate schoolchildren that are not needed due to children being picked up by their parents, can be gainfully assigned to service other facilities or those persons who do not have access to private vehicles or to ride-sharing.

Table 8-3 presents a list of the reception centers for each school, pre-school, and day camp in the EPZ.

Children will be transported to these reception centers where they will be subsequently retrieved by their respective families.

Braidwood Generating Station 8-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

8.3 Medical Facility Demand Table 8-4 presents the census of the medical facility within the EPZ. A total of 129 people have been identified as living in, or being treated in this facility. The current census for the facility was provided by Exelon and by county emergency management personnel.

The transportation requirements for the medical facility population are also presented in Table 8-4. The number of ambulance runs is determined by assuming that 2 patients can be accommodated per ambulance trip; the number of wheelchair bus runs assumes 15 wheelchairs per trip and the number of bus runs estimated assumes 30 ambulatory patients per trip.

8.4 Evacuation Time Estimates for Transit Dependent People EPZ bus resources are assigned to evacuating children (if schools, pre-schools, or day camps are in session at the time of the ATE) as the first priority in the event of an emergency. In the event that the allocation of buses dispatched from the depots to the various facilities and to the bus routes is somewhat "inefficient", or if there is a shortfall of available drivers, then there may be a need for some buses to return to the EPZ from the reception center after completing their first evacuation trip, to complete a "second wave" of providing transport service to evacuees.

For this reason, the ETE for the transit-dependent population will be calculated for both a one wave transit evacuation and for two waves. Of course, if the impacted Evacuation Region is other than R03 (the entire EPZ), then there will likely be ample transit resources relative to demand in the impacted Region and this discussion of a second wave would likely not apply.

When school evacuation needs are satisfied, subsequent assignments of buses to service the transit-dependent should be sensitive to their mobilization time. Clearly, the buses should be dispatched after people have completed their mobilization activities and are in a position to board the buses when they arrive at the pick-up points.

Evacuation Time Estimates for transit trips were developed using both good weather and adverse weather conditions. Figure 8-1 presents the chronology of events relevant to transit operations. The elapsed time for each activity will now be discussed with reference to Figure 8-1.

Activity: Mobilize Drivers (A->B->QC)

Mobilization is the elapsed time from the Advisory to Evacuate until the time the buses arrive at the facility to be evacuated. It is assumed that for a rapidly escalating radiological emergency with no observable indication before the fact, school bus drivers would likely require 90 minutes to be contacted, to travel to the depot, be briefed, and to travel to the transit-dependent facilities. Mobilization time is slightly longer in adverse weather - 100 minutes when raining, 110 minutes when snowing.

Braidwood Generating Station 8-4 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Activity: Board Passengers (C-->D)

A loading time of 15 minutes (20 minutes for rain and 25 minutes for snow) for school buses is assumed.

For multiple stops along a pick-up route, (transit-dependent bus routes) estimation of travel time must allow for the delay associated with stopping and starting at each pick-up point. The time, t, required for a bus to decelerate at a rate, "a", expressed in ft/sec/sec, from a speed, "v", expressed in ft/sec, to a stop, is t = v/a. Assuming the same acceleration rate and final speed following the stop yields a total time, T, to service boarding passengers:

2v T=t+B+t=B+2t=B+--,

a Where B = Dwell time to service passengers. The total distance, "s" in feet, travelled during the deceleration and acceleration activities is: s = v2/a. If the bus had not stopped to service passengers, but had continued to travel at speed, v, then its travel time over the distance, s, would be: s/v = v/a. Then the total delay (i.e. pickup time, P) to service passengers is:

a a

Assigning reasonable estimates:

B = 50 seconds: a generous value for a single passenger, carrying personal items, to board per stop S

v = 25 mph = 37 ft/sec a = 4 ft/sec/sec, a moderate average rate Then, P = 1 minute per stop. Allowing 30 minutes pick-up time per bus run implies 30 stops per run, for good weather. It is assumed that bus acceleration and speed will be less in rain; total loading time is 40 minutes per bus in rain, 50 minutes in snow.

Activity: Travel to EPZ Boundary (D->E)

School, Pre-School, and Day Camp Evacuation Transportation resources available were provided by Exelon and are summarized in Table 8-5.

Also included in the table is the number of buses needed to evacuate schools, pre-schools, day camps, medical facilities, transit-dependent population, homebound special needs population (discussed below in Section 8.5), and correctional facilities (discussed below in Section 8.6).

These numbers indicate there are sufficient resources available to evacuate all transit-dependent people in a single wave.

The buses servicing the schools, pre-schools, and day camps are ready to begin their evacuation trips at 105 minutes after the advisory to evacuate - 90 minutes mobilization time plus 15 minutes loading time - in good weather. The UNITES software discussed in Section 1.3 was used to define bus routes along the most likely path from a school being evacuated to the EPZ boundary, traveling toward the appropriate reception center. This is done in UNITES by interactively selecting the series of nodes from the school to the EPZ boundary. Each bus route is given an identification number and is written to the DYNEV II input stream. DYNEV computes Braidwood Generating Station 8-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

the route length and outputs the average speed for each 5 minute interval, for each bus route.

The specified bus routes are documented in Table 8-6 (refer to the maps of the link-node analysis network in Appendix K for node locations). Data provided by DYNEV during the appropriate timeframe depending on the mobilization and loading times (i.e., 100 to 105 minutes after the advisory to evacuate for good weather) were used to compute the average speed for each route, as follows:

Average Speed(y-)

hrhr length of link i (mi) 60 min.

=X x

onlength of link i (mi.)

60 min 1hr.

{Delay onlink(min.

current speed on link i m

Xlhr.

The average speed computed (using this methodology) for the buses servicing each of the schools, pre-schools, and day camps in the EPZ is shown in Table 8-7 through Table 8-9 for school, pre-school and day camp evacuation, and in Table 8-11 through Table 8-13 for the transit vehicles evacuating transit-dependent persons, which are discussed later. The travel time to the EPZ boundary was computed for each bus using the computed average speed and the distance to the EPZ boundary along the most likely route out of the EPZ. The travel time from the EPZ boundary to the Reception Center was computed assuming an average speed of 55 mph, 50 mph, and 45 mph for good weather, rain and snow, respectively. Speeds were reduced in Table 8-7 through Table 8-9 and in Table 8-11 through Table 8-13 to 55 mph (50 mph for rain and 45 mph for snow) for those calculated bus speeds which exceed 55 mph, as the school bus speed limit for state routes in Illinois is 55 mph.

Table 8-7 (good weather), Table 8-8 (rain) and Table 8-9 (snow) present the following evacuation time estimates (rounded up to the nearest 5 minutes) for schools, pre-schools, and day camps in the EPZ: (1) The elapsed time from the Advisory to Evacuate until the bus exits the EPZ; and (2) The elapsed time until the bus reaches the Reception Center (R.C.). The evacuation time out of the EPZ can be computed as the sum of times associated with Activities A--B-->C, C->D, and D->E (For example: 90 min. + 15 + 15 = 2:00 for Braceville Elementary School, in good weather). The average ETE for a single-wave evacuation of schools, pre-schools and day camps is equal to the 9 0 th percentile ETE for the general population for an evacuation of the entire EPZ (Region R03) during Scenario 6 conditions. The evacuation time to the Reception Center is determined by adding the time associated with Activity E--)F (discussed below), to this EPZ evacuation time.

Evacuation of Transit-Dependent Population The buses dispatched from the depots to service the transit-dependent evacuees will be scheduled so that they arrive at their respective routes after their passengers have completed Braidwood Generating Station 8-6 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

their mobilization.

As shown in Figure 5-4 (Residents with no Commuters), nearly all (97%)

evacuees will complete their mobilization when the buses will begin their routes, approximately 120 minutes after the Advisory to Evacuate.

Those buses servicing the transit-dependent evacuees will first travel along their pick-up routes, then proceed out of the EPZ. The state and county emergency plans do not define routes or assembly points to service the transit dependent population. The 8 bus routes shown graphically in Figure 8-2 and described in Table 8-10 were designed as part of this study to service population centers within Sub-areas of the EPZ. It is assumed that residents will walk to and congregate along these routes, and that they can arrive at the routes to be picked up within the 120 minute bus mobilization time during good weather (130 minutes and 140 minutes in rain and snow, respectively).

As previously discussed, a pickup time of 30 minutes (good weather) is estimated for 30 individual stops to pick up passengers, with an average of one minute of delay associated with each stop. Longer pickup times of 40 minutes and 50 minutes are used for rain and snow, respectively.

The travel distance along the respective routes within the EPZ is estimated using the UNITES software. Bus travel times within the EPZ are computed using average speeds computed by DYNEV, using the aforementioned methodology that was used for school, preschool and camp evacuation.

Table 8-11 through Table 8-13 present the transit-dependent population evacuation time estimates for each bus route calculated using the above procedures for good weather, rain and snow, respectively. For example, the ETE for the bus route servicing Sub-area 1 is computed as 120 + 17 + 30 = 2:50 for good weather, rounded up to the nearest 5 minutes. Here, 17 minutes is the time to travel 14.2 miles at 50.5 mph, the average speed output by the model for this route starting at 120 minutes. The ETE for a second wave (discussed below) is presented in the event there is a shortfall of available buses or bus drivers, as previously discussed.

Activity: Travel to Reception Centers (E--F)

The distances from the EPZ boundary to the reception centers are measured using GIS software along the most likely route from the EPZ exit point to the reception center. The reception centers are mapped in Figure 10-1. For a one-wave evacuation, this travel time outside the EPZ does not contribute to the ETE.

For a two-wave evacuation, the ETE for buses must be considered separately, since it could exceed the ETE for the general population. Assumed bus speeds of 55 mph, 50 mph, and 45 mph for good weather, rain, and snow, respectively, will be applied for this activity for buses servicing the transit-dependent population.

Activity: Passengers Leave Bus (F-4G)

A bus can empty within 5 minutes. The driver takes a 10 minute break.

Activity: Bus Returns to Route for Second Wave Evacuation (G->C)

The buses assigned to return to the EPZ to perform a "second wave" evacuation of transit-dependent evacuees will be those that have already evacuated transit-dependent people who Braidwood Generating Station 8-7 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

mobilized more quickly. The first wave of transit-dependent people depart the bus, and the bus then returns to the EPZ, travels to its route and proceeds to pick up more transit-dependent evacuees along the route. The travel time back to the EPZ is equal to the travel time to the reception center.

The second-wave ETE for the bus route servicing Sub-area 1 is computed as follows for good weather:

Bus arrives at reception center at 3:05 in good weather (2:50 to exit EPZ + 15 minute travel time to reception center).

Bus discharges passengers (5 minutes) and driver takes a 10-minute rest: 15 minutes.

Bus returns to EPZ and completes second-wave service along the route: 15 minutes (equal to travel time to reception center) + 16 minutes (14.2 miles @ 55 mph to return to the start of the route) + 16 minutes (14.2 miles @ 53.2 mph to traverse the route providing second-wave bus service) = 47 minutes Bus completes pick-ups along route: 30 minutes.

Bus exits EPZ at time 2:50 + 0:15 + 0:15 + 0:47 + 0:30 = 4:40 (rounded up to nearest 5 minutes) after the Advisory to Evacuate.

The ETE for the completion of the second wave for all transit-dependent bus routes are provided in Table 8-11 through Table 8-13. The average ETE for a one-wave evacuation of transit-dependent people is 40 minutes longer than the ETE for the general population at the 90th percentile for an evacuation of the entire EPZ (Region R03) during Scenario 6 conditions.

The two-wave evacuation of transit-dependent people is 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and 35 minutes longer on average than the ETE for the general population at the 9 0 th percentile for an evacuation of the entire EPZ during Scenario 6 conditions.

Evacuation of Medical Facilities The evacuation of these facilities is similar to school evacuation except:

Buses are assigned on the basis of 30 patients to allow for staff to accompany the patients.

Wheelchair buses can accommodate 15 patients.

Ambulances can accommodate 2 patients.

Loading times of 1 minute, 5 minutes, and 15 minutes per patient are assumed for ambulatory

patients, wheelchair bound
patients, and bedridden
patients, respectively.

Table 8-4 indicates that 3 bus runs, 4 wheelchair bus runs, and 6 ambulance runs are needed to service the medical facility in the EPZ. According to Table 8-5, the counties and the one medical facility can collectively provide 635 buses, 51 vans, 63 wheelchair buses, and 49 ambulances.

Thus, there are ample resources to evacuate the medical facility population in a single wave.

As is done for the schools, it is estimated that mobilization time averages 90 minutes (100 in rain and 110 in snow). Specially trained medical support staff (working their regular shift) will Braidwood Generating Station 8-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

be on site to assist in the evacuation of patients. Additional staff (if needed) could be mobilized over this same 90-minute timeframe.

Table 8-14 through Table 8-16 summarize the ETE for the medical facility within the EPZ for good weather, rain, and snow. Average speeds output by the model for Scenario 6 (Scenario 7 for rain and Scenario 8 for snow) Region 3, capped at 55 mph (50 mph for rain and 45 mph for snow), are used to compute travel time to EPZ boundary. The travel time to the EPZ boundary is computed by dividing the distance to the EPZ boundary by the average travel speed. The ETE is the sum of the mobilization time, total passenger loading time, and travel time out of the EPZ. Concurrent loading on multiple buses, wheelchair buses, and ambulances at capacity is assumed such that the maximum loading times for buses, wheelchair buses, and ambulances are 30 minutes, 75 minutes, and 30 minutes, respectively.

All ETE are rounded up to the nearest 5 minutes. For example, the calculation of ETE for Island City Rehab Center with 64 ambulatory residents during good weather is:

ETE: 90 + 1 x 30+ 10 = 130 min. or 2:10 It is assumed that the medical facility population is directly evacuated to appropriate host medical facilities outside of the EPZ. Relocation of this population to permanent facilities and/or passing through the reception center before arriving at the host facility are not considered in this analysis.

8.5 Special Needs Population The special needs population registered within the EPZ was provided by the county emergency management personnel. There are 433 homebound special needs people within the EPZ who required transportation assistance to evacuate.

Using the same breakdown (approximately 50% ambulatory, 41% wheelchair-bound, and 9% bed-ridden) for the medical facility within the EPZ (Table 8-4), 215 special needs people require a bus, 178 would require a wheelchair accessible vehicle, and 40 would require an ambulance.

ETE for Homebound Special Needs Persons Table 8-17 summarizes the ETE for homebound special needs people. The table is categorized by type of vehicle required and then broken down by weather condition. The table takes into consideration the deployment of multiple vehicles to reduce the number of stops per vehicle.

It is conservatively assumed that ambulatory and wheelchair bound households are spaced 3 miles apart and bedridden households are spaced 5 miles apart. Bus and wheelchair bus speeds approximate 20 mph between households and ambulance speeds approximate 30 mph in good weather (10% slower in rain, 20% slower in snow). Mobilization times of 90 minutes were used (100 minutes for rain, and 110 minutes for snow). Loading times of 5 minutes per person are assumed for ambulatory and wheelchair bound people and 15 minutes per person are assumed for bedridden people. The last HH is assumed to be 5 miles from the EPZ boundary, and the network-wide average speed, capped at 55 mph (50 mph for rain and 45 mph for snow), after the last pickup is used to compute travel time. ETE is computed by summing mobilization time, loading time at first household, travel to subsequent households, Braidwood Generating Station 8-9 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

loading time at subsequent households, and travel time to EPZ boundary. All ETE are rounded to the nearest 5 minutes.

For example, assuming no more than one special needs person per HH implies that 215 ambulatory households need to be serviced. Given a bus capacity of 30 people, 8 buses are needed to service the population. While only 8 buses are needed from a capacity standpoint, if 43 buses are deployed to service these special needs HH, then each would require at most 5 stops. The following outlines the ETE calculations:

1. Assume 43 buses are deployed, each with about 5 stops, to service a total of 215 HH.
2.

ETE is equal to the total time to complete the following activities:

a.

Bus arrive at the first pickup location: 90 minutes

b.

Load HH members at first pickup: 5 minutes

c. Travel to subsequent pickup locations: 4 @ 9 minutes = 36 minutes
d. Load HH members at subsequent pickup locations: 4 @ 5 minutes = 20 minutes
e. Travel to EPZ boundary: 6 minutes (5 miles @ 49.8 mph).

ETE: 90 + 5 + 36 + 20 + 6 = 2:40 (rounded up to the nearest 5 minutes)

Table 8-5 indicates that there are sufficient transportation resources available in the EPZ to evacuate the medical facilities and the homebound special needs population simultaneously.

The average ETE for a single wave evacuation of the homebound special needs population is approximately 20 minutes longer than the general population ETE at the 9 0 th percentile for an evacuation of the entire EPZ (Region R03).

8.6 Correctional Facilities The previous ETE report (2003) included the Kankakee Minimum Security Unit. As of April 2010, that facility has been closed. Therefore, there are no operational correctional facilities within the EPZ, and no ETE have been calculated.

Braidwood Generating Station Evacuation Time Estimate 8-10 KLD Engineering, P.C.

Rev. 0

(Subsequent Wave)

Time A

Advisory to Evacuate B

Bus Dispatched from Depot C

Bus Arrives at Facility/Pick-up Route D

Bus Departs for Reception Center E

Bus Exits Region F

Bus Arrives at Reception Center/Host Facility G

Bus Available for "Second Wave" Evacuation Service A->B Driver Mobilization B-->C Travel to Facility or to Pick-up Route C-->D Passengers Board the Bus D-->E Bus Travels Towards Region Boundary E->F Bus Travels Towards Reception Center Outside the EPZ F-*G Passengers Leave Bus; Driver Takes a Break Figure 8-1. Chronology of Transit Evacuation Operations Braidwood Generating Station 8-11 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure 8-2. BWD Transit Dependent Bus Routes Braidwood Generating Station Evacuation Time Estimate 8-12 KLD Engineering, P.C.

Rev. 0

Table 8-1. Transit-Dependent Population Estimates Averag e

Percen Pecn

.H Siz Toa Pepl Population Avrg Hwt oa H

frH eol siae eurn eurn 39,762 2.40 16,568 3.1%

514 1

1.07 1

550 1

50%

275 0.7%

Table 8-1. Transit-Dependent Population Estimates Braidwood Generating Station Evacuation Time Estimate 8-13 KLD Engineering, P.C.

Rev. 0

Table 8-2. School, Pre-School, and Day Camp Population Demand Estimates 7

Coal City Elementary School 328 1

5 10 Braceville Elementary School 176 3

10 Coal City High School 652 14 10 Coal City Intermediate School 315 7

10 Coal City Middle School 488 10 12 M.V.K. Elementary School 189 3

12 M.V.K. Middle School 149 3

14 South Wilmington Grade School 89 2

15 Gardner Elementary School 228 4

15 Gardner/South Wilmington High School 209 5

Shadow Region White Oak Elementary 842 13 Region' Grundy County Subtotal 3,665 69 KANKAKEE COUNTY 9

Reddick Grade School 119 2

Kankakee County Subtotal 119 2

WILLCOUNTY 1

Reed-Custer High School 595 12 1

Reed-Custer Intermediate School 508 11 1

Reed-Custer Middle School 391 8

5 L.J. Stevens Intermediate School 400 8

5 St. Rose School 144 3

5 Trinity Services Island City 25 1

5 Wilmington High School 474 10 5

Wilmington Middle School 330 7

13 Bruning Elementary School 251 4

13 Reed-Custer Primary School 295 5

Will County Subtotal 3,413 69 4

Boy Scouts of America 1,000 20 8

Rainbow Preschool 38 1

1 Facility is located just beyond the EPZ boundary; however, the facility will evacuate as per county plans.

Braidwood Generating Station Evacuation Time Estimate 8-14 KLD Engineering, P.C.

Rev. 0

Sub ue are Failt Na eErlmet Rq ie 10 1

Coal City Early Childhood Center 351 6

10 Kid's Korner 24 1

10 Step by Step Child Care Center -

103 2

Diamond Grundy County Subtotal 1,516 30 WILL COUNTY 1

Godley Park District Child Care Center 102 2

1 Shepherd's Flock Pre-School 30 1

1 Step by Step Child Care Center -

129 2

Braidwood 5

Discovery Schoolhouse 37 1

5 Grace Lutheran Preschool 30 1

Will County Subtotal 328 7

Braidwood Generating Station Evacuation Time Estimate 8-15 KLD Engineering, P.C.

Rev. 0

Table 8-3. School, Pre-School, and Day Camp Reception Centers Facility~~*

ReetonCne GRUNDY COUNTY Braceville Elementary School Coal City Elementary School Coal City High School Coal City Intermediate School Coal City Middle School Gardner Elementary School Pontiac Township High School Gardner/South Wilmington High School M.V.K. Elementary School M.V.K. Middle School South Wilmington Grade School White Oak Elementary KANKAKEE COUNTY Reddick Grade School

]

Pontiac Township High School WILL COUNTY Bruning Elementary School L.J. Stevens Intermediate School Reed-Custer High School Reed-Custer Intermediate School Reed-Custer Middle School Joliet Junior College St. Rose School Wilmington High School Wilmington Middle School Reed-Custer Primary School Kankakee Community College Trinity Services Island City PESCHOOS AN AYAP GRUNDY COUNTY Rainbow Preschool Illinois Valley Community College Boy Scouts of America Coal City Early Childhood Center Pontiac Township High School Kid's Korner Step by Step Child Care Center - Diamond WILL COUNTY Discovery Schoolhouse Godley Park District Child Care Center Grace Lutheran Preschool Joliet Junior College Shepherd's Flock Pre-School Step by Step Child Care Center - Braidwood Braidwood Generating Station Evacuation Time Estimate 8-16 KLD Engineering, P.C.

Rev. 0

Table 8-4. Medical Facility Transit Demand 5

Island City Rehab Center Wilmington 171 129 64 53 12 3

4 6

Braidwood Generating Station Evacuation Time Estimate 8-17 KLD Engineering, P.C.

Rev. 0

Table 8-5. Summary of Transportation Resources Grundy County 80 8

6 2

Kankakee County 189 0

26 23 Kendall County 85 9

5 2

LaSalle County 31 3

2 4

Will County 250 30 23 18 Island City Rehab Center 0

1 1

0 Schools, Pre-Schools, Day Camps (Table 8-21):

177 0

0 0

Medical Facilities (Table 8-4):

3 0

4 6

Transit-Dependent Population (Table 8-10):

10 0

0 0

Homebound Special Needs (Table 8-17):

43 0

30 20 Braidwood Generating Station Evacuation Time Estimate 8-18 KLD Engineering, P.C.

Rev. 0

Table 8-6. Bus Route Descriptions Bus 0

  • I Rout Noe Trvre fro Rot trtt.P 3

Reed-Custer High School, Reed-Custer Middle School 508,1453,510,509,511 L.J. Stevens Intermediate School, Wilmington High School, St. Rose School, Island City Rehab Center, Wilmington 529,528,527 Middle School, Grace Lutheran Preschool, Discovery Schoolhouse, Trinity Services Island City 12 Bruning Elementary School 526, 525, 524 20 Coal City Elementary School 1413, 439, 1414, 1579, 440, 502, 1581, 441, 407 21 Rainbow Preschool 405, 1310, 406, 407 22 Coal City Intermediate School 1411, 439, 1414, 1579, 440, 502, 1581, 441, 407 23 Coal City High School 440, 502, 1581, 441, 407 24 Braceville Elementary School 481, 452,453, 454, 455 25 Coal City Middle School, Coal City Early 494,440,502,1581,441,407 Childhood Center 26 Kid's Korner 1414, 1579, 440, 502, 1581, 441, 407 50 Reed-Custer Primary School 513, 514, 515 506, 444, 443, 35, 34, 45, 46, 33, 32, 31, 30, 52 Reed-Custer Intermediate School 29,4131 29, 1331 56 Reddick Grade School 996, 997, 998 61 M.V.K. Elementary School, M.V.K.

410, 1437, 411, 889, 1312, 1018, 1042, 1041, Middle School 1040 458, 459, 460, 461, 462, 463, 491, 492, 42, 63 South Wilmington Grade School45,94641424341424, 43, 1044, 1045, 1043, 1042, 1041, 1040 490, 463, 491, 492, 42, 43, 1044, 1045, 1043, 64 Gardner Elementary School 14,14,14 1042, 1041, 1040 456, 463, 491, 492, 42, 43, 1044, 1045, 1043, 65 Gardner/South Wilmington High School 42,41,40 1042, 1041, 1040 66 Godley Park District Child Care Center, 499, 37, 36, 35, 34, 45, 46, 33, 32, 31, 30, 29, Shepherd's Flock Pre-School 1331 1410, 438, 1411, 439, 1414, 1579, 440, 502, 68 Diamond 1581, 441, 407, 408, 409, 410, 1437, 411, 889, 1312, 1018, 1042, 1041, 1040 69 Step by Step Child Care Center -

505, 506, 444, 443, 35, 34, 45, 46, 33, 32, 31, Braidwood 30, 29, 1331 71 Boy Scouts of America 416, 417, 418, 419, 420, 421, 422, 404, 405, 1310, 406, 407 Braidwood Generating Station Evacuation Time Estimate 8-19 KLD Engineering, P.C.

Rev. 0

Bus.

  • 0 Rout Noe Trvre fro Rot6.rtt P

82 Transit Dependent - Sub-area 1 499,505,506,476,477,507,508,1453,510, 509,511,512,513,514,515,1462,516,517, 972,973,1404,1503,1405,971 412, 413, 414, 415, 501, 416, 417, 418, 419, 83 Transit Dependent -Sub-area 4 40 2,42 0,10 420,421,422,404,1307 528,529,530,531,1396,1397,567,1399, 84 Transit Dependent - Sub-area 5 566,565,591,590,589,588,587,986,29, 1331 85 Transit Dependent - Sub-area 7 437,438,1411,439,1414,1579,440,502, 1581,441,407,406,1310,405,404,1307 86 Transit Dependent - Sub-area 8 1309,405,404,1307 439,1414,1579,440,502,1581,441,407, 87 Transit Dependent -Sub-area 1040,10,0544,37406,1310,405,404,1307 528,527,526,525,524,523,522,521, 985, 520,1401,519,518,1402,1403,970,971 455,456,457,458,459,460,461,1005, 89 Transit Dependent-Sub-area 151006,1007,1008,1009 Note: White Oak Elementary not listed since the facility is located just outside the EPZ Braidwood Generating Station Evacuation Time Estimate.

8-20 KLD Engineering, P.C.

Rev. 0

Table 8-7. School, Pre-School, and Day Camp Evacuation Time Estimates - Good Weather lV

-1K*l m'

Braceville Elementary School 90 15 13.4 53.7 15 Coal City Elementary School 90 15 20.5 11.3 109 Coal City High School 90 15 19.5 11.0 106 Coal City Intermediate School 90 15 20.5 11.1 111 Coal City Middle School 90 15 19.8 11.3 105 Gardner Elementary School 90 15 10.1 55.0 11 Gardner/South Wilmington High School 90 15 9.8 55.0 11 M.V.K. Elementary School 90 15 10.9 54.8 12 M.V.K. Middle School 90 15 10.8 54.8 12 South Wilmington Grade School 90 15 12.3 55.0 13 White Oak Elementary 90 15 Located Outside EPZ 2 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 24 24 24 24 24 24 24 24 24 24 40.2 44 KANKAKEE COUNTY Reddick Grade School 90 15 1 0.4]

47.6 [

1 35 3 71S SWILL COUNTY Bruning Elementary School 90 15 6.9 46.2 9

L.J. Stevens Intermediate School 90 15 5.2 42.5 7

Reed-Custer High School 90 15 8.7 53.7 10 Reed-Custer Intermediate School 90 15 9.2 38.5 14 Reed-Custer Middle School 90 15 8.9 53.7 10 Reed-Custer Primary School 90 15 7.2 55.0 8

St. Rose School 90 15 4.8 42.5 7

Trinity Services Island City 90 15 10.0 42.3 14 Wilmington High School 90 15 5.7 42.5 8

17.5 17.5 10.4 10.4 10.4 13.5 17.5 13.5 17.5 19 19 11 11 11 15 19 15 19 2 Facility is located just outside the EPZ; however, the facility will evacuate as per county plans. ETE for this facility is not included in the average for the EPZ.

Braidwood Generating Station Evacuation Time Estimate 8-21 KLD Engineering, P.C.

Rev. 0

WILL COUNTY Discovery Schoolhouse 90 15 5.4 42.5 8

Godley Park District Child Care Center 90 15 11.2 44.7 15 Grace Lutheran Preschool 90 15 5.6 42.5 8

Shepherd's Flock Pre-School 90 15 9.9 43.0 14 Step by Step Child Care Center -

90 15 9.3 37.7 15 Braidwood 90 I59. 3_7 Pre-School, Day Camp Maximum for EPZ:

Pre-School, Day Camp Average for EPZ:

17.5 10.4 17.5 10.4 19 11 19 11 10.4 1

11 Pre-School, Day Camp Maximum:

Pre-School, Day Camp Average:

Braidwood Generating Station Evacuation Time Estimate 8-22 KLD Engineering, P.C.

Rev. 0

Table 8-8. School, Pre-School, and Day Camp Evacuation Time Estimates - Rain GRUNDY COUNTY Braceville Elementary School 100 20 13.4 48.6 17 Coal City Elementary School 100 20 20.5 11.3 109 Coal City High School 100 20 19.5 11.0 106 Coal City Intermediate School 100 20 20.5 11.1 111 Coal City Middle School 100 20 19.8 11.3 105 Gardner Elementary School 100 20 10.1 50.0 12 Gardner/South Wilmington High School 100 20 9.8 50.0 12 M.V.K. Elementary School 100 20 10.9 50.0 13 M.V.K. Middle School 100 20 10.8 50.0 13 South Wilmington Grade School 100 20 12.3 50.0 15 White Oak Elementary 100 20 Located Outside EPZ 3 KANKAKEE COUNTY Reddick Grade School 100 20 1

0.4 43.1 1

SWILL COUNTY Bruning Elementary School 100 20 6.9 43.8 9

L.J. Stevens Intermediate School 100 20 5.2 37.3 8

Reed-Custer High School 100 20 8.7 50.0 10 Reed-Custer Intermediate School 100 20 9.2 36.2 15 Reed-Custer Middle School 100 20 8.9 50.0 11 Reed-Custer Primary School 100 20 7.2 50.0 9

St. Rose School 100 20 4.8 37.3 8

Trinity Services Island City 100 20 10.0 34.8 17 Wilmington High School 100 20 5.7 37.3 9

22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 27 27 27 27 27 27 27 27 27 27 40.2 48 31.7 1 38 1 24 17.5 17.5 10.4 10.4 10.4 13.5 17.5 13.5 17.5 21 21 12 12 12 16 21 16 21 Facility is located just outside the EPZ; however, the facility will evacuate as per county plans. ETE for this facility is not included in the average for the EPZ.

Braidwood Generating Station Evacuation Time Estimate 8-23 KLD Engineering, P.C.

Rev. 0

WILL COUNTY Discovery Schoolhouse 100 20 5.4 37.3 9

Godley Park District Child Care Center 100 20 11.2 39.8 17 Grace Lutheran Preschool 100 20 5.6 37.3 9

Shepherd's Flock Pre-School 100 20 9.9 39.9 15 Step by Step Child Care Center -

100 20 9.3 35.5 16 Braidwood 10I2_93_5.

I16 Pre-School, Day Camp Maximum for EPZ:

Pre-School, Day Camp Average for EPZ:

17.5 10.4 17.5 10.4 21 12 21 12 10.4 12 Pre-School, Day Camp Maximum:

Pre-School, Day Camp Average:

Braidwood Generating Station Evacuation Time Estimate 8-24 KLD Engineering, P.C.

Rev. 0

Table 8-9. School, Pre-School, and Day Camp Evacuation Time Estimates - Snow Braceville Elementary School 110 25 13.4 43.6 18 Coal City Elementary School 110 25 20.5 8.9 138 Coal City High School 110 25 19.5 8.5 137 Coal City Intermediate School 110 25 20.5 9.3 133 Coal City Middle School 110 25 19.8 8.9 134 Gardner Elementary School 110 25 10.1 45.0 13 Gardner/South Wilmington High School 110 25 9.8 45.0 13 M.V.K. Elementary School 110 25 10.9 45.0 15 M.V.K. Middle School 110 25 10.8 45.0 14 South Wilmington Grade School 110 25 12.3 45.0 16 White Oak Elementary 110 25 Located Outside EPZ 4 KANKAKEE COUNTY Reddick Grade School T

110 1 25 0.4 [ 38.0 1

3 1 31.7 1 42 WILL COUNTY Bruning Elementary School 110 25 6.9 41.8 10 L.J. Stevens Intermediate School 110 25 5.2 34.2 9

Reed-Custer High School 110 25 8.7 45.0 12 Reed-Custer Intermediate School 110 25 9.2 28.1 20 Reed-Custer Middle School 110 25 8.9 45.0 12 Reed-Custer Primary School 110 25 7.2 43.7 10 St. Rose School 110 25 4.8 34.2 8

Trinity Services Island City 110 25 10.0 34.2 18 Wilmington High School 110 25 5.7 34.2 10 17.5 17.5 10.4 10.4 10.4 13.5 17.5 13.5 17.5 23 23 14 14 14 18 23 18 23 Facility is located just outside the EPZ; however, the facility will evacuate as per county plans. ETE for this facility is not included in the average for the EPZ.

Braidwood Generating Station Evacuation Time Estimate 8-25 KLD Engineering, P.C.

Rev. 0

t3KUNUY LUN I Y Boy Scouts of America 110 25 23.1 42.6 33 Coal City Early Childhood Center 110 25 20.0 8.9 135 Kid's Korner 110 25 19.9 8.7 137 Rainbow Preschool 110 25 1.6 45.0 2

Step by Step Child Care Center -

110 25 21.4 12.6 102 Diamond 1I0 25 2I.4 12.6 102 WILL COUNTY Discovery Schoolhouse 110 25 5.4 34.2 9

Godley Park District Child Care Center 110 25 11.2 32.2 21 Grace Lutheran Preschool 110 25 5.6 34.2 10 Shepherd's Flock Pre-School 110 25 9.9 30.2 20 Step by Step Child Care Center -

110 25 9.3 29.3 19 Braidwood 1I0 25 9.3 29.3 19 Pre-School, Day Camp Maximum for EPZ:

Pre-School, Day Camp Average for EPZ:

22.7 22.4 22.4 43.3 30 30 30 58 22.4 30 17.5 23 10.4 14 17.5 23 10.4 14 10.4 14 Pre-School, Day Camp Maximum:

Pre-School, Day Camp Average:

Braidwood Generating Station Evacuation Time Estimate 8-26 KLD Engineering, P.C.

Rev. 0

Table 8-10. Summary of Transit-Dependent Bus Routes

-o.

of Length-Name Buses Route Description (m

iL Sub-area 1 2

Sub-area 4 Sub-area 5 Sub-area 7 Picks up evacuees along West Kennedy Road, South Division Street, IL-113 through Braidwood and to the EPZ boundary. Travels to the Reception Center 14.2 located at Kankakee Community College.

Picks up evacuees along Pine Bluff Road West from the intersection of North Dresden Road to IL-47 North to the EPZ boundary. Travels to the Reception 8.9 Center located at Joliet Junior College.

Picks up evacuees along IL-102 North to North Water Street to Chicago Street to North Kankakee Street to West Kankakee River Drive to North River Road to 1-55 North to the EPZ boundary. Travels to the Reception Center located at Joliet Junior College.

Picks up evacuees along IL-113 West from the intersection of South Will Road to IL-47 North to the EPZ boundary. Travels to the Reception Center located at 14.3 Joliet Junior College.

Picks up evacuees along Higgins Road North from the intersection of IL-113 to Southmar Road to IL-47 North to the EPZ boundary. Travels to the Reception 6.9 Center located at Joliet Junior College.

Picks up evacuees along North Mitchell Street in Braceville to West Division Street to County Route 8000 E to Spring Road to South Broadway Street to IL-113 West to IL-47 North to the EPZ boundary. Travels to the Reception Center located at Joliet Junior College.

Picks up evacuees along IL-102 South from the EPZ boundary between Sub-area 5 and Sub-area 13 to North 7000W Road to the EPZ boundary. Travels to the 9.5 Reception Center located at Kankakee Community College.

Sub-area 8 Sub-area 10 Sub-area 13 Braidwood Generating Station Evacuation Time Estimate 8-27 KLD Engineering, P.C.

Rev. 0

No ofLnt Nam Bue Rot Decito0mL Sub-area 15 1

Picks up evacuees along IL-53 South from the intersection of County Route 6000 to Washington Street to East Street to West Main Street to Old US-66 to the EPZ boundary. Travels to the Reception Center located at Pontiac Township High School.

8.6

4.

4-Total:

10 Braidwood Generating Station Evacuation Time Estimate 8-28 KLD Engineering, P.C.

Rev. 0

Table 8-11. Transit-Dependent Evacuation Time Estimates - Good Weather Sub-area 1 I 1-2 120 1 14.2 1 50.5 17 30 13.5 15 5

10 47 30 Sub-area 4 1

120 8.9 28.9 18 30 Sub-area 5 1

120 7.8 41.8 11 30 Sub-area 7 1

120 14.3 14.5 59 30 Sub-area 8 1

120 6.9 16.8 25 30 Sub-area 10 1-2 120 18.6 18.5 60 30 Sub-area 13 1

120 9.5 49.4 12 30 Sub-area 15 1

120 8.6 54.3 10 30 Maximum ETE:

Average ETE:

20.0 22 5

10 41 30 11.2 12 5

10 31 30 20.0 22 5

10 53 30 20.0 22 5

10 39 30 20.0 22 5

10 63 30 24.0 26 5

10 47 30 24.0 26 5

10 45 30 Braidwood Generating Station Evacuation Time Estimate 8-29 KLD Engineering, P.C.

Rev. 0

Table 8-12. Transit-Dependent Evacuation Time Estimates - Rain Sub-area 1 1-2 130 14.2 43.9 19 40 Sub-area 4 1

130 8.9 23.8 22 40 Sub-area 5 1

130 7.8 29.1 16 40 Sub-area 7 1

130 14.3 13.1 65 40 Sub-area 8 1

130 6.9 14.1 29 40 Sub-area 10 1-2 130 18.6 16.9 66 40 Sub-area 13 1

130 9.5 44.5 13 40 Sub-area 15 1

130 8.6 48.4 11 40 Maximum ETE:

Average ETE:

13.5 16 5

10 49 40 20.0 24 5

10 44 40 11.2 13 5

10 33 40 20.0 24 5

10 57 40 20.0 24 5

10 42 40 20.0 24 5

10 67 40 24.0 29 5

10 51 40 24.0 29 5

10 49 40 Maximum ETE:

Average ETE:

Braidwood Generating Station Evacuation Time Estimate 8-30 KLD Engineering, P.C.

Rev. 0

Table 8-13. Transit Dependent Evacuation Time Estimates - Snow I Sub-area 1 1-2 140 14.2 39.4 22 50 13.5 18 5

10 53 50 Sub-area 4 1

140 8.9 18.6 29 50 Sub-area 5 1

140 7.8 18.9 25 50 Sub-area 7 1

140 14.3 10.6 81 s0 Sub-area 8 1

140 6.9 13.4 31 50 Sub-area 10 1-2 140 18.6 13.9 80 50 Sub-area 13 1

140 9.5 41.0 14 50 Sub-area 15 1

140 8.6 44.0 12 50 Maximum ETE:

Average ETE:

20.0 27 5

10 49 50 11.2 15 5

10 36 50 20.0 27 5

10 62 50 20.0 27 5

10 47 50 20.0 27 5

10 72 50 24.0 32 5

10 55 50 24.0 32 5

10 53 50 Maximum ETE:

Average ETE:

Braidwood Generating Station Evacuation Time Estimate 8-31 KLD Engineering, P.C.

Rev. 0

Table 8-14. Medical Facility Evacuation Time Estimates - Good Weather Moiizto (mi pe Loain Dit To

.0 ondr I AmhiiI~tnrv I

qn I

1 1 64I 30 5.7 I

10 2:10

.--.---. 1v 1 IslandCity Rehab Center Wheelchair bound 90 Bedridden 90 5

I 53 1

75 I

5.7 I

8 2:55 15 I

12 I

30 I

5.7 I

10 2:10 Maximum ETE:

2:55 Average ETE:1 2:25 Table 8-15. Medical Facility Evacuation Time Estimates - Rain Island City Ambulatory 100 1

6430 5.7 12 2:2 Rehab Center Wheelchair bound 100 5

53 75 5.7 9

3:05 Bedridden 100 15 12 30 5.7 12 2:25 Maximum ETE:

3:05 Average ETE:

2:40 Braidwood Generating Station Evacuation Time Estimate 8-32 KLD Engineering, P.C.

Rev. 0

Table 8-16. Medical Facility Evacuation Time Estimates - Snow m

.Travel.

-Ladn Tim to

  • S

~

S I AmhliI~tnr, I

u1n I

I1ga I

  • nl I

7 I

in Island City l

1 1

1 64 1

30 1

Rehab Center Wheelchair bound 110 5

53 75 5.7 12 3:20 I Bedridden I

110 I

15 I

12 I

30 I

5.7 I

10 2:30 Maximum ETE:

3:20 Average EUE:

2:50 Braidwood Generating Station Evacuation Time Estimate 8-33 KLD Engineering, P.C.

Rev. 0

Table 8-17. Homebound Special Needs Population Evacuation Time Estimates Busesin 21hcle 43ahe Tim Rai 100p Susqun 40squn 20ndr Good 90 6

2:40 Buses 215 43 5Rain 1000 20 7

2:55 Snow 110 8

3:10 Wheelchair Good 90 145 6

2:55 Whee 178 30 6

Rain 100 5

50 25 7

3:10 Buses Snow 110 55 8

3:25 Good 9010 6

2:20 Ambulances 40 20 2

Rain 100 15 11 15 7

2:30 1

1 Snow 110 13 7

2:40 Maximum ETE:

3:25 Average ETE:

2:55 Braidwood Generating Station Evacuation Time Estimate 8-34 KLD Engineering, P.C.

Rev. 0

9 TRAFFIC MANAGEMENT STRATEGY This section discusses the suggested traffic control and management strategy that is designed to expedite the movement of evacuating traffic. The resources required to implement this strategy include:

Personnel with the capabilities of performing the planned control functions of traffic guides (preferably, not necessarily, law enforcement officers).

" Traffic Control Devices to assist these personnel in the performance of their tasks. These devices should comply with the guidance of the Manual of Uniform Traffic Control Devices (MUTCD) published by the Federal Highway Administration (FHWA) of the U.S.D.O.T. All state and most county transportation agencies have access to the MUTCD, which is available on-line: http://mutcd.fhwa.dot.gov which provides access to the official PDF version.

A plan that defines all locations, provides necessary details and is documented in a format that is readily understood by those assigned to perform traffic control.

The functions to be performed in the field are:

1. Facilitate evacuating traffic movements that safely expedite travel out of the EPZ.
2. Discourage traffic movements that move evacuating vehicles in a direction which takes them significantly closer to the power plant, or which interferes with the efficient flow of other evacuees.

We employ the terms "facilitate" and "discourage" rather than "enforce" and "prohibit" to indicate the need for flexibility in performing the traffic control function. There are always legitimate reasons for a driver to prefer a direction other than that indicated. For example:

A driver may be traveling home from work or from another location, to join other family members prior to evacuating.

" An evacuating driver may be travelling to pick up a relative, or other evacuees.

" The driver may be an emergency worker en route to perform an important activity.

The implementation of a plan must also be flexible enough for the application of sound judgment by the traffic guide.

The traffic management plan is the outcome of the following process:

1. The existing TCPs and ACPs identified by the offsite agencies in their emergency plans serve as the basis of the traffic management plan, as per NUREG/CR-7002.
2. Computer analysis of the evacuation traffic flow environment (see Figures 7-3 through 7-7).

This analysis identifies the best routing and those critical intersections that experience pronounced congestion. Any critical intersections that would benefit from traffic or access control which are not already identified in the existing offsite plans are suggested as additional TCPs and ACPs.

Braidwood Generating Station 9-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

3. The existing TCPs and ACPs, and how they were applied in this study, are discussed in Appendix G.
4. Prioritization of TCPs and ACPs.

Application of traffic and access control at some TCPs and ACPs will have a more pronounced influence on expediting traffic movements than at other TCPs and ACPs. For example, TCPs controlling traffic originating from areas in close proximity to the power plant could have a more beneficial effect on minimizing potential exposure to radioactivity than those TCPs located far from the power plant. These priorities should be assigned by state/local emergency management representatives and by law enforcement personnel.

The pronounced traffic congestion along IL-113 westbound and IL-47 southbound discussed in Section 7.3 is the result of the many vehicles evacuating from the densely populated communities of Carbon Hill, Coal City and Diamond, and the limited northbound evacuation routes leaving the EPZ. Additional TCPs or ACPs or modification to existing TCPs and ACPs does not alleviate this congestion. The existing traffic management plans are adequate.

The use of Intelligent Transportation Systems (ITS) technologies can reduce manpower and equipment needs, while still facilitating the evacuation process. Dynamic Message Signs (DMS) can be placed within the EPZ to provide information to travelers regarding traffic conditions, route selection, and reception center information. DMS can also be placed outside of the EPZ to warn motorists to avoid using routes that may conflict with the flow of evacuees away from the power plant.

Highway Advisory Radio (HAR) can be used to broadcast information to evacuees en route through their vehicle stereo systems. Automated Traveler Information Systems (ATIS) can also be used to provide evacuees with information. Internet websites can provide traffic and evacuation route information before the evacuee begins their trip, while on board navigation systems (GPS units), cell phones, and pagers can be used to provide information en route. These are only several examples of how ITS technologies can benefit the evacuation process. Consideration should be given that ITS technologies be used to facilitate the evacuation process, and any additional signage placed should consider evacuation needs.

The ETE analysis treated all controlled intersections that are existing ACP or TCP locations in the offsite agency plans as being controlled by actuated signals. Appendix K, Table K-2 identifies those intersections that were modeled as TCPs.

Chapters 2N and 5G, and Part 6 of the 2009 MUTCD are particularly relevant and should be reviewed during emergency response training.

The ETE calculations reflect the assumption that all "external-external" trips are interdicted and diverted after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> have elapsed from the ATE.

All transit vehicles and other responders entering the EPZ to support the evacuation are assumed to be unhindered by personnel manning ACPs and TCPs.

Study Assumptions 5 and 6 in Section 2.3 discuss ACP and TCP staffing schedules and operations.

Braidwood Generating Station 9-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

10 EVACUATION ROUTES Evacuation routes are comprised of two distinct components:

" Routing from a Sub-area being evacuated to the boundary of the Evacuation Region and thence out of the EPZ.

Routing of transit-dependent evacuees from the EPZ boundary to reception communities or reception centers.

Evacuees will select routes within the EPZ in such a way as to minimize their exposure to risk.

This expectation is met by the DYNEV II model routing traffic away from the location of the plant, to the extent practicable. The DTRAD model satisfies this behavior by routing traffic so as to balance traffic demand relative to the available highway capacity to the extent possible.

See Appendices B through D for further discussion.

The routing of transit-dependent evacuees from the EPZ boundary to reception communities or reception centers is designed to minimize the amount of travel outside the EPZ, from the points where these routes cross the EPZ boundary.

The Radiological Emergency Response Plan (REP) for the State of Illinois indicates evacuees can receive congregate care at reception centers.

Figure 10-1 presents an overview of the general population reception communities (listed in the public information) and reception centers (listed in the state and county RERP) servicing the EPZ. Note reception centers serve both the school population and the general public. The major evacuation routes for the EPZ are presented in Figure 10-2.

It is assumed that all school evacuees will be taken to the appropriate reception center and subsequently picked up by parents or guardians. Transit-dependent evacuees are transported to the nearest reception community.

Braidwood Generating Station Evacuation Time Estimate 10-1 KLD Engineering, P.C.

Rev. 0

Jo i a Jooietno Sh iI.....

.n I

C

' ~

tO I o otOS*

M a n h a t t a n Jolie Ca63*T Col..,

\\

/, let ")

-- j >.

.1 '

P.-n

-P

own,

,1 I.,

ill b-r 1

01

' &urtontt 1 G7 2

Pit Boitktttt.

I7 (C.in

. ~

~-1e wo d!..

ii, BW I

d Legend DonkLni Gtn nn U

Reception Center P nta 4,

etn*

"1 U Reception Community KnnTtwhtp ig on 4f I "I S..t-SSub-area1 0....In IRg C.

2,5, 10, le Shadow Region n

y i

n. a/nloom a 0 (47>

tonotngtn.

thesaoeo.t 2

Figure 10-1. General Population Reception Communities and Reception Centers Braidwood Generating Station 10-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure 10-2. Major Evacuation Routes Braidwood Generating Station Evacuation Time Estimate 10-3 KLD Engineering, P.C.

Rev. 0

11 SURVEILLANCE OF EVACUATION OPERATIONS There is a need for surveillance of traffic operations during the evacuation. There is also a need to clear any blockage of roadways arising from accidents or vehicle disablement. Surveillance can take several forms.

1. Traffic control personnel, located at Traffic and Access Control points, provide fixed-point surveillance.
2. Ground patrols may be undertaken along well-defined paths to ensure coverage of those highways that serve as major evacuation routes.
3. Aerial surveillance of evacuation operations may also be conducted using helicopter or fixed-wing aircraft, if available.
4. Cellular phone calls (if cellular coverage exists) from motorists may also provide direct field reports of road blockages.

These concurrent surveillance procedures are designed to provide coverage of the entire EPZ as well as the area around its periphery. It is the responsibility of the counties to support an emergency response system that can receive messages from the field and be in a position to respond to any reported problems in a timely manner. This coverage should quickly identify and expedite the response to any blockage caused by a disabled vehicle.

Tow Vehicles In a low-speed traffic environment, any vehicle disablement is likely to arise due to a low-speed collision, mechanical failure or the exhaustion of its fuel supply. In any case, the disabled vehicle can be pushed onto the shoulder, thereby restoring traffic flow. Past experience in other emergencies indicates that evacuees who are leaving an area often perform activities such as pushing a disabled vehicle to the side of the road without prompting.

While the need for tow vehicles is expected to be low under the circumstances described above, it is still prudent to be prepared for such a need. Consideration should be given that tow trucks with a supply of gasoline be deployed at strategic locations within, or just outside, the EPZ. These locations should be selected so that:

" They permit access to key, heavily loaded, evacuation routes.

Responding tow trucks would most likely travel counter-flow relative to evacuating traffic.

The state RERP discusses the use of snowplows to assist disabled vehicles and to remove debris from highways. Consideration should also be given that the state and local emergency management agencies encourage gas stations to remain open during the evacuation.

Braidwood Generating Station 11-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

12 CONFIRMATION TIME It is necessary to confirm that the evacuation process is effective in the sense that the public is complying with the Advisory to Evacuate. The offsite agency radiological emergency plans do not discuss a procedure for confirming evacuation. Should procedures not already exist, the following alternative or complementary approach is suggested.

The suggested procedure employs a stratified random sample and a telephone survey. The size of the sample is dependent on the expected number of households that do not comply with the Advisory to Evacuate. It is reasonable to assume for the purpose of estimating sample size that at least 80 percent of the population within the EPZ will comply with the Advisory to Evacuate.

On this basis, an analysis could be undertaken (see Table 12-1) to yield an estimated sample size of approximately 300.

The confirmation process should start at about 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the Advisory to Evacuate, which is when more than 90 percent of evacuees have begun their evacuation trip (see Figure 5-4). At this time, virtually all evacuees will have departed on their respective trips and the local telephone system will be largely free of traffic.

As indicated in Table 12-1, approximately 7Y2 person hours are needed to complete the telephone survey.

If six people are assigned to this task, each dialing a different set of telephone exchanges (e.g., each person can be assigned a different set of Sub-areas), then the confirmation process will extend over a timeframe of about 75 minutes. Thus, the confirmation should be completed before the evacuated area is cleared. Of course, fewer people would be needed for this survey if the Evacuation Region were only a portion of the EPZ. Use of modern automated computer controlled dialing equipment or other technologies (e.g., reverse 911 or equivalent if available) can significantly reduce the manpower requirements and the time required to undertake this type of confirmation survey.

If this method is indeed used by the offsite agencies, consideration should be given to maintain a list of telephone numbers within the EPZ in the EOC at all times. Such a list could be purchased from vendors and could be periodically updated. As indicated above, the confirmation process should not begin until 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the Advisory to Evacuate, to ensure that households have had enough time to mobilize. This 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> s timeframe will enable telephone operators to arrive at their workplace, obtain a call list and prepare to make the necessary phone calls.

Should the number of telephone responses (i.e., people still at home) exceed 20 percent, then the telephone survey should be repeated after an hour's interval until the confirmation process is completed.

Other techniques could also be considered.

After traffic volumes decline, the personnel manning TCPs can be redeployed to travel through residential areas to observe and to confirm evacuation activities.

Braidwood Generating Station 12-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Table 12-1. Estimated Number of Telephone Calls Required for Confirmation of Evacuation Problem Definition Estimate number of phone calls, n, needed to ascertain the proportion, F of households that have not evacuated.

Reference:

Burstein, H., Attribute Sampling. McGraw Hill, 1971 Given:

No. of households plus other facilities, N, within the EPZ (est.) = 16,600 Est. proportion, F, of households that will not evacuate = 0.20

" Allowable error margin, e: 0.05 Confidence level, a: 0.95 (implies A = 1.96)

Applying Table 10 of cited reference, p=F+e=0.25; q=1-p=0.75 A 2 pq + e =

n =

- 308 e2 Finite population correction:

nN nF-

= 303 n+N-1

=0 Thus, some 300 telephone calls will confirm that approximately 20 percent of the population has not evacuated. If only 10 percent of the population does not comply with the Advisory to Evacuate, then the required sample size, nF = 213.

Est. Person Hours to complete 300 telephone calls Assume:

" Time to dial using touch tone (random selection of listed numbers): 30 seconds

" Time for 6 rings (no answer): 36 seconds

" Time for 4 rings plus short conversation: 60 sec.

Interval between calls: 20 sec.

Person Hours:

300[30 + 0.8(36) + 0.2(60) + 20]

3600 7.6 3600 Braidwood Generating Station 12-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

13 REFERENCES

Agarwal, M.

et. al.

Proceedings of the 2005 Mid-Continent Transportation Research Symposium, "Impacts of Weather on Urban Freeway Traffic Flow Characteristics and Facility Capacity," August 2005. (Agarwal, 2005).

Exelon. EP-AA-1001, Revision 31, "Exelon Nuclear Radiological Emergency Plan Annex for Braidwood Station," June 2013. (Exelon, 2013).

Highway Performance Monitoring System (HPMS), Federal Highway Administration (FHWA),

Washington, D.C., 2013. (HPMS, 2013).

Institute for Environmental Studies (IES), University of Toronto. "The Mississauga Evacuation Final Report," June 1981. (IES, 1981).

Lieberman, E. Publication Transportation Research Record 772, "Determining Lateral Deployment of Traffic on an Approach to an Intersection," 1980. (Lieberman, 1980).

Lieberman, E., Xin, W. "Macroscopic Traffic Modeling For Large-Scale Evacuation Planning",

presented at the TRB 2012 Annual Meeting, January 2012. (Lieberman, 2012).

McShane, W. & Lieberman, E. "Service Rates of Mixed Traffic on the far Left Lane of an Approach," Publication Transportation Research Record 772, 1980. (McShane, 1980).

Nuclear Regulatory Commission (NRC). NUREG/CR-1745, "Analysis of Techniques for Estimating Evacuation Times for Emergency Planning Zones," November, 1980. (NRC, 1980a).

Nuclear Regulatory Commission (NRC). NUREG/CR-4873, PNL-6171, "Benchmark Study of the I-DYNEV Evacuation Time Estimate Computer Code," 1988. (NRC, 1988a).

Nuclear Regulatory Commission (NRC).

NUREG/CR-4874, PNL-6172, "The Sensitivity of Evacuation Time Estimates to Changes in Input Parameters for the I-DYNEV Computer Code,"

1988. (NRC, 1988b).

Nuclear Regulatory Commission (NRC).

NUREG-0654/FEMA-REP-1, Rev.

1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980. (NRC, 1980b).

Nuclear Regulatory Commission (NRC). NUREG/CR-6863, SAND2004-5900, "Development of Evacuation Time Estimate Studies for Nuclear Power Plants," January 2005. (NRC, 2005).

Nuclear Regulatory Commission (NRC). NUREG/CR-7002, SAND 2010-0061P, "Criteria for Development of Evacuation Time Estimate Studies," November 2011. (NRC, 2011a).

Nuclear Regulatory Commission (NRC).

Title 10, Code of Federal Regulations, Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities, 2011.

(NRC, 2011b).

State of Illinois, "Illinois Plan For Radiological Accidents (IPRA) Braidwood - Volume VII," March 2012. (IPRA, 2012).

Braidwood Generating Station 13-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Transportation Research Board (TRB). "Highway Capacity Manual." National Research Council, Washington, DC, 2010. (TRB, 2010).

Zhang, L. and Levinson, D. "Some Properties of Flows at Freeway Bottlenecks," Transportation Research Record 1883, 2004. (Zhang, 2004).

Braidwood Generating Station Evacuation Time Estimate 13-2 KLD Engineering, P.C.

Rev. 0

APPENDIX A Glossary of Traffic Engineering Terms

A. GLOSSARY OF TRAFFIC ENGINEERING TERMS Table A-i. Glossary of Traffic Engineering Terms Term~I Deiito Analysis Network Link Measures of Effectiveness Node Origin Prevailing Roadway and Traffic Conditions A graphical representation of the geometric topology of a physical roadway system, which is comprised of directional links and nodes.

A network link represents a specific, one-directional section of roadway.

A link has both physical (length, number of lanes, topology, etc.) and operational (turn movement percentages, service rate, free-flow speed) characteristics.

Statistics describing traffic operations on a roadway network.

A network node generally represents an intersection of network links.

A node has control characteristics, i.e., the allocation of service time to each approach link.

A location attached to a network link, within the EPZ or Shadow Region, where trips are generated at a specified rate in vehicles per hour (vph). These trips enter the roadway system to travel to their respective destinations.

Relates to the physical features of the roadway, the nature (e.g.,

composition) of traffic on the roadway and the ambient conditions (weather, visibility, pavement conditions, etc.).

Maximum rate at which vehicles, executing a specific turn maneuver, can be discharged from a section of roadway at the prevailing conditions, expressed in vehicles per second (vps) or vehicles per hour (vph).

Maximum number of vehicles which can pass over a section of roadway in one direction during a specified time period with operating conditions at a specified Level of Service (The Service Volume at the upper bound of Level of Service, E, equals Capacity).

Service Volume is usually expressed as vehicles per hour (vph).

The total elapsed time to display all signal indications, in sequence.

The cycle length is expressed in seconds.

A single combination of signal indications. The interval duration is expressed in seconds. A signal phase is comprised of a sequence of signal intervals, usually green, yellow, red.

Service Rate Service Volume Signal Cycle Length Signal Interval Braidwood Generating Station Evacuation Time Estimate A-1 KLD Engineering, P.C.

Rev. 0

I TermDefiniio Signal Phase Traffic (Trip) Assignment Traffic Density Traffic (Trip) Distribution Traffic Simulation Traffic Volume Travel Mode Trip Table or Origin-Destination Matrix Turning Capacity A set of signal indications (and intervals) which services a particular combination of traffic movements on selected approaches to the intersection. The phase duration is expressed in seconds.

A process of assigning traffic to paths of travel in such a way as to satisfy all trip objectives (i.e., the desire of each vehicle to travel from a specified origin in the network to a specified destination) and to optimize some stated objective or combination of objectives.

In general, the objective is stated in terms of minimizing a generalized "cost".

For example, "cost" may be expressed in terms of travel time.

The number of vehicles that occupy one lane of a roadway section of specified length at a point in time, expressed as vehicles per mile (vpm).

A process for determining the destinations of all traffic generated at the origins. The result often takes the form of a Trip Table, which is a matrix of origin-destination traffic volumes.

A computer model designed to replicate the real-world operation of vehicles on a roadway network, so as to provide statistics describing traffic performance.

These statistics are called Measures of Effectiveness.

The number of vehicles that pass over a section of roadway in one direction, expressed in vehicles per hour (vph). Where applicable, traffic volume may be stratified by turn movement.

Distinguishes between private auto, bus, rail, pedestrian and air travel modes.

A rectangular matrix or table, whose entries contain the number of trips generated at each specified origin, during a specified time period, that are attracted to (and travel toward) each of its specified destinations. These values are expressed in vehicles per hour (vph) or in vehicles.

The capacity associated with that component of the traffic stream which executes a specified turn maneuver from an approach at an intersection.

Braidwood Generating Station Evacuation Time Estimate A-2 KLD Engineering, P.C.

Rev. 0

APPENDIX B DTRAD: Dynamic Traffic Assignment and Distribution Model

B. DYNAMIC TRAFFIC ASSIGNMENT AND DISTRIBUTION MODEL This section describes the integrated dynamic trip assignment and distribution model named DTRAD (Dynamic Traffic Assignment and Distribution) that is expressly designed for use in analyzing evacuation scenarios. DTRAD employs logit-based path-choice principles and is one of the models of the DYNEV II System. The DTRAD module implements path-based Dynamic Traffic Assignment (DTA) so that time dependent Origin-Destination (OD) trips are "assigned" to routes over the network based on prevailing traffic conditions.

To apply the DYNEV II System, the analyst must specify the highway network, link capacity information, the time-varying volume of traffic generated at all origin centroids and, optionally, a set of accessible candidate destination nodes on the periphery of the EPZ for selected origins.

DTRAD calculates the optimal dynamic trip distribution (i.e., trip destinations) and the optimal dynamic trip assignment (i.e., trip routing) of the traffic generated at each origin node traveling to its set of candidate destination nodes, so as to minimize evacuee travel "cost."

Overview of Integrated Distribution and Assignment Model The underlying premise is that the selection of destinations and routes is intrinsically coupled in an evacuation scenario. That is, people in vehicles seek to travel out of an area of potential risk as rapidly as possible by selecting the "best" routes. The model is designed to identify these "best" routes in a manner that realistically distributes vehicles from origins to destinations and routes them over the highway network, in a consistent and optimal manner, reflecting evacuee behavior.

For each origin, a set of "candidate destination nodes" is selected by the software logic and by the analyst to reflect the desire by evacuees to travel away from the power plant and to access major highways. The specific destination nodes within this set that are selected by travelers and the selection of the connecting paths of travel, are both determined by DTRAD. This determination is made by a logit-based path choice model in DTRAD, so as to minimize the trip "cost", as discussed later.

The traffic loading on the network and the consequent operational traffic environment of the network (density, speed, throughput on each link) vary over time as the evacuation takes place.

The DTRAD model, which is interfaced with the DYNEV simulation model, executes a succession of "sessions" wherein it computes the optimal routing and selection of destination nodes for the conditions that exist at that time.

Interfacing the DYNEV Simulation Model with DTRAD The DYNEV II system reflects NRC guidance that evacuees will seek to travel in a general direction away from the location of the hazardous event. An algorithm was developed to support the DTRAD model in dynamically varying the Trip Table (O-D matrix) over time from one DTRAD session to the next. Another algorithm executes a "mapping" from the specified "geometric" network (link-node analysis network) that represents the physical highway system, to a "path" network that represents the vehicle [turn] movements. DTRAD computations are performed on the "path" network: DYNEV simulation model, on the "geometric" network.

Braidwood Generating Station B-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

DTRAD Description DTRAD is the DTA module for the DYNEV II System.

When the road network under study is large, multiple routing options are usually available between trip origins and destinations. The problem of loading traffic demands and propagating them over the network links is called Network Loading and is addressed by DYNEV II using macroscopic traffic simulation modeling. Traffic assignment deals with computing the distribution of the traffic over the road network for given O-D demands and is a model of the route choice of the drivers. Travel demand changes significantly over time, and the road network may have time dependent characteristics, e.g., time-varying signal timing or reduced road capacity because of lane closure, or traffic congestion. To consider these time dependencies, DTA procedures are required.

The DTRAD DTA module represents the dynamic route choice behavior of drivers, using the specification of dynamic origin-destination matrices as flow input. Drivers choose their routes through the network based on the travel cost they experience (as determined by the simulation model). This allows traffic to be distributed over the network according to the time-dependent conditions. The modeling principles of DTRAD include:

It is assumed that drivers not only select the best route (i.e., lowest cost path) but some also select less attractive routes. The algorithm implemented by DTRAD archives several "efficient" routes for each O-D pair from which the drivers choose.

The choice of one route out of a set of possible routes is an outcome of "discrete choice modeling". Given a set of routes and their generalized costs, the percentages of drivers that choose each route is computed. The most prevalent model for discrete choice modeling is the logit model. DTRAD uses a variant of Path-Size-Logit model (PSL).

PSL overcomes the drawback of the traditional multinomial logit model by incorporating an additional deterministic path size correction term to address path overlapping in the random utility expression.

DTRAD executes the traffic assignment algorithm on an abstract network representation called "the path network" which is built from the actual physical link-node analysis network. This execution continues until a stable situation is reached: the volumes and travel times on the edges of the path network do not change significantly from one iteration to the next. The criteria for this convergence are defined by the user.

Travel "cost" plays a crucial role in route choice. In DTRAD, path cost is a linear summation of the generalized cost of each link that comprises the path. The generalized cost for a link, a, is expressed as c,, = ata + /ll,

+ ysa,,

where cois the generalized cost for link a, anda,,8, andyare cost coefficients for link travel time, distance, and supplemental cost, respectively. Distance and supplemental costs are defined as invariant properties of the network model, while travel time is a dynamic property dictated by prevailing traffic conditions. The DYNEV simulation model Braidwood Generating Station B-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

computes travel times on all edges in the network and DTRAD uses that information to constantly update the costs of paths. The route choice decision model in the next simulation iteration uses these updated values to adjust the route choice behavior. This way, traffic demands are dynamically re-assigned based on time dependent conditions.

The interaction between the DTRAD traffic assignment and DYNEV II simulation models is depicted in Figure B-1. Each round of interaction is called a Traffic Assignment Session (TA session). A TA session is composed of multiple iterations, marked as loop B in the figure.

The supplemental cost is based on the "survival distribution" (a variation of the exponential distribution). The Inverse Survival Function is a "cost" term in DTRAD to represent the potential risk of travel toward the plant:

Sa= - 13 In (p), 0 < p < I; 13 >0 d,

Pdo dn= Distance of node, n, from the plant do =Distance from the plant where there is zero risk 13

= Scaling factor The value of do = 15 miles, the outer distance of the Shadow Region.

Note that the supplemental cost, sa, of link, a, is (high, low), if its downstream node, n, is (near, far from) the power plant.

Braidwood Generating Station Evacuation Time Estimate B-3 KLD Engineering, P.C.

Rev. 0

Network Equilibrium In 1952, John Wardrop wrote:

Under equilibrium conditions traffic arranges itself in congested networks in such a way that no individual trip-maker can reduce his path costs by switching routes.

The above statement describes the "User Equilibrium" definition, also called the "Selfish Driver Equilibrium". It is a hypothesis that represents a [hopeful] condition that evolves over time as drivers search out alternative routes to identify those routes that minimize their respective "costs". It has been found that this "equilibrium" objective to minimize costs is largely realized by most drivers who routinely take the same trip over the same network at the same time (i.e.,

commuters). Effectively, such drivers "learn" which routes are best for them over time. Thus, the traffic environment "settles down" to a near-equilibrium state.

Clearly, since an emergency evacuation is a sudden, unique event, it does not constitute a long-term learning experience which can achieve an equilibrium state. Consequently, DTRAD was not designed as an equilibrium solution, but to represent drivers in a new and unfamiliar situation, who respond in a flexible manner to real-time information (either broadcast or observed) in such a way as to minimize their respective costs of travel.

Braidwood Generating Station Evacuation Time Estimate B-4 KLD Engineering, P.C.

Rev. 0

Start of next DTRAD Session 1 Set To = Clock time.

Archive System State at To I

Define latest Link Turn Percentages B

Execute Simulation Model from time, To to T1 (burn time) l Provide DTRAD with link MOE at time, T1 I

Execute DTRAD iteration; Get new Turn Percentages I

Retrieve System State at To Apply new Link Turn Percents DTRAD iteration converges?

No Yes Simulate from To to T2 (DTA session duration)

Set Clock to T7 Figure B-1. Flow Diagram of Simulation-DTRAD Interface Braidwood Generating Station Evacuation Time Estimate B-5 KLD Engineering, P.C.

Rev. 0

APPENDIX C DYNEV Traffic Simulation Model

C. DYNEV TRAFFIC SIMULATION MODEL The DYNEV traffic simulation model is a macroscopic model that describes the operations of traffic flow in terms of aggregate variables: vehicles, flow rate, mean speed, volume, density, queue length, on each link, for each turn movement, during each Time Interval (simulation time step). The model generates trips from "sources" and from Entry Links and introduces them onto the analysis network at rates specified by the analyst based on the mobilization time distributions. The model simulates the movements of all vehicles on all network links over time until the network is empty. At intervals, the model outputs Measures of Effectiveness (MOE) such as those listed in Table C-1.

Model Features Include:

Explicit consideration is taken of the variation in density over the time step; an iterative procedure is employed to calculate an average density over the simulation time step for the purpose of computing a mean speed for moving vehicles.

Multiple turn movements can be serviced on one link; a separate algorithm is used to estimate the number of (fractional) lanes assigned to the vehicles performing each turn movement, based, in part, on the turn percentages provided by the DTRAD model.

" At any point in time, traffic flow on a link is subdivided into two classifications: queued and moving vehicles. The number of vehicles in each classification is computed. Vehicle spillback, stratified by turn movement for each network link, is explicitly considered and quantified. The propagation of stopping waves from link to link is computed within each time step of the simulation. There is no "vertical stacking" of queues on a link.

Any link can accommodate "source flow" from zones via side streets and parking facilities that are not explicitly represented. This flow represents the evacuating trips that are generated at the source.

The relation between the number of vehicles occupying the link and its storage capacity is monitored every time step for every link and for every turn movement.

If the available storage capacity on a link is exceeded by the demand for service, then the simulator applies a "metering" rate to the entering traffic from both the upstream feeders and source node to ensure that the available storage capacity is not exceeded.

A "path network" that represents the specified traffic movements from each network link is constructed by the model; this path network is utilized by the DTRAD model.

A two-way interface with DTRAD: (1) provides link travel times; (2) receives data that translates into link turn percentages.

Provides MOE to animation software, EVAN Calculates ETE statistics Braidwood Generating Station C-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

All traffic simulation models are data-intensive. Table C-2 outlines the necessary input data elements.

To provide an efficient framework for defining these specifications, the physical highway environment is represented as a network. The unidirectional links of the network represent roadway sections: rural, multi-lane, urban streets or freeways.

The nodes of the network generally represent intersections or points along a section where a geometric property changes (e.g. a lane drop, change in grade or free flow speed).

Figure C-1 is an example of a small network representation. The freeway is defined by the sequence of links, (20,21), (21,22), and (22,23). Links (8001, 19) and (3, 8011) are Entry and Exit links, respectively. An arterial extends from node 3 to node 19 and is partially subsumed within a grid network. Note that links (21,22) and (17,19) are grade-separated.

Table C-1. Selected Measures of Effectiveness Output by DYNEV II Measure~£0 Unt-ppisT Vehicles Discharged Vehicles Link, Network, Exit Link Speed Miles/Hours (mph)

Link, Network Density Vehicles/Mile/Lane Link Level of Service LOS Link Content Vehicles Network Travel Time Vehicle-hours Network Evacuated Vehicles Vehicles Network, Exit Link Trip Travel Time Vehicle-minutes/trip Network Capacity Utilization Percent Exit Link Attraction Percent of total evacuating vehicles Exit Link Max Queue Vehicles Node, Approach Time of Max Queue Hours:minutes Node, Approach Route Statistics Length (mi); Mean Speed (mph); Travel Route Time (min)

Mean Travel Time Minutes Evacuation Trips; Network Braidwood Generating Station Evacuation Time Estimate C-2 KLD Engineering, P.C.

Rev. 0

Table C-2. Input Requirements for the DYNEV II Model HIGHWAY NETWORK Links defined by upstream and downstream node numbers Link lengths Number of lanes (up to 9) and channelization

" Turn bays (1 to 3 lanes)

Destination (exit) nodes Network topology defined in terms of downstream nodes for each receiving link Node Coordinates (X,Y)

Nuclear Power Plant Coordinates (X,Y)

GENERATED TRAFFIC VOLUMES On all entry links and source nodes (origins), by Time Period TRAFFIC CONTROL SPECIFICATIONS Traffic signals: link-specific, turn movement specific Signal control treated as fixed time or actuated Location of traffic control points (these are represented as actuated signals)

Stop and Yield signs Right-turn-on-red (RTOR)

Route diversion specifications

" Turn restrictions Lane control (e.g. lane closure, movement-specific)

DRIVER'S AND OPERATIONAL CHARACTERISTICS Driver's (vehicle-specific) response mechanisms: free-flow speed, discharge headway Bus route designation.

DYNAMIC TRAFFIC ASSIGNMENT Candidate destination nodes for each origin (optional)

Duration of DTA sessions Duration of simulation "burn time" Desired number of destination nodes per origin INCIDENTS Identify and Schedule of closed lanes Identify and Schedule of closed links Braidwood Generating Station C-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Entry, Exit Nodes are numbered 8xxx Figure C-1. Representative Analysis Network Braidwood Generating Station Evacuation Time Estimate C-4 KLD Engineering, P.C.

Rev. 0

C.1 Methodology C.1.1 The Fundamental Diagram It is necessary to define the fundamental diagram describing flow-density and speed-density relationships. Rather than "settling for" a triangular representation, a more realistic representation that includes a "capacity drop", (I-R)Qmax, at the critical density when flow conditions enter the forced flow regime, is developed and calibrated for each link. This representation, shown in Figure C-2, asserts a constant free speed up to a density, kf, and then a linear reduction in speed in the range, kf_ _ k _< kc = 45 vpm, the density at capacity. In the flow-density plane, a quadratic relationship is prescribed in the range, kc < k _* ks = 95 vpm which roughly represents the "stop-and-go" condition of severe congestion. The value of flow rate, Qs, corresponding to ks, is approximated at 0.7 RQmax.

A linear relationship between ks and kj completes the diagram shown in Figure C-2. Table C-3 is a glossary of terms.

The fundamental diagram is applied to moving traffic on every link. The specified calibration values for each link are: (1) Free speed, vf ; (2) Capacity, Qmax ; (3) Critical density, kc =

45 vpm; (4) Capacity Drop Factor, R = 0.9 ; (5) Jam density, ki. Then, vc = Qmax, kf = kc -

I kc (Vf-Vc) k* Setting k = k-kc, thenQ-=RRQmax RQmax k2 for 0_<k_<k

=50. It can be Qmax 8333 shown that Q = (0.98 - 0.0056 k) RQmax for ks - k

  • kj, where ks = 50 and W, = 175.

C.1.2 The Simulation Model The simulation model solves a sequence of "unit problems". Each unit problem computes the movement of traffic on a link, for each specified turn movement, over a specified time interval (TI) which serves as the simulation time step for all links. Figure C-3 is a representation of the unit problem in the time-distance plane. Table C-3 is a glossary of terms that are referenced in the following description of the unit problem procedure.

Braidwood Generating Station C-5 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Volume, vph R

,= Qs A

Vf R vc riowegimes, mph:'re Free,Forced' I-I I

I I

Density, vpm p-Density, vpm kf k

Figure C-2. Fundamental Diagrams Distance Qb Mb OQ OM OE Qe Me O

Down Up Time L

El E2 TI Figure C-3. A UNIT Problem Configuration with tj > 0 Braidwood Generating Station Evacuation Time Estimate C-6 KLD Engineering, P.C.

Rev. 0

Table C-3. Glossary The maximum number of vehicles, of a particular movement, that can discharge Cap from a link within a time interval.

The number of vehicles, of a particular movement, that enter the link over the time interval. The portion, ETI, can reach the stop-bar within the TI.

The green time: cycle time ratio that services the vehicles of a particular turn movement on a link.

h The mean queue discharge headway, seconds.

k Density in vehicles per lane per mile.

The average density of moving vehicles of a particular movement over a TI, on a link.

L The length of the link in feet.

Lb, Le The queue length in feet of a particular movement, at the [beginning, end] of a time interval.

The number of lanes, expressed as a floating point number, allocated to service a particular movement on a link.

ILv The mean effective length of a queued vehicle including the vehicle spacing, feet.

M Metering factor (Multiplier): 1.

The number of moving vehicles on the link, of a particular movement, that are Mb, Me moving at the [beginning, end] of the time interval. These vehicles are assumed to be of equal spacing, over the length of link upstream of the queue.

The total number of vehicles of a particular movement that are discharged from a link over a time interval.

The components of the vehicles of a particular movement that are discharged OQOM 0O.

from a link within a time interval: vehicles that were Queued at the beginning of the TI; vehicles that were Moving within the link at the beginning of the TI; vehicles that Entered the link during the TI.

The percentage, expressed as a fraction, of the total flow on the link that executes a particular turn movement, x.

Braidwood Generating Station C-7 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Qb, Qe The number of queued vehicles on the link, of a particular turn movement, at the

[beginning, end] of the time interval.

The maximum flow rate that can be serviced by a link for a particular movement Qmax in the absence of a control device. It is specified by the analyst as an estimate of link capacity, based upon a field survey, with reference to the HCM.

R The factor that is applied to the capacity of a link to represent the "capacity drop" when the flow condition moves into the forced flow regime. The lower capacity at that point is equal to RQmax.

RCap The remaining capacity available to service vehicles of a particular movement after that queue has been completely serviced, within a time interval, expressed as vehicles.

Sx Service rate for movement x, vehicles per hour (vph).

t1 Vehicles of a particular turn movement that enter a link over the first tj seconds of a time interval, can reach the stop-bar (in the absence of a queue down-stream) within the same time interval.

TI The time interval, in seconds, which is used as the simulation time step.

v The mean speed of travel, in feet per second (fps) or miles per hour (mph), of moving vehicles on the link.

VQ The mean speed of the last vehicle in a queue that discharges from the link within the TI. This speed differs from the mean speed of moving vehicles, v.

W The width of the intersection in feet. This is the difference between the link length which extends from stop-bar to stop-bar and the block length.

Braidwood Generating Station Evacuation Time Estimate C-8 KLD Engineering, P.C.

Rev. 0

The formulation and the associated logic presented below are designed to solve the unit problem for each sweep over the network (discussed below), for each turn movement serviced on each link that comprises the evacuation network, and for each TI over the duration of the evacuation.

Given= Qb, Mb, L, TI, Eo, LN, G/C, h, Lv, Ro, L, E,M Compute = 0, Qe, Me Define O=OQ+OM+OE ; E=E +E 2

1. For the first sweep, s = 1, of this TI, get initial estimates of mean density, ko, the R - factor, Ro and entering traffic, Eo, using the values computed for the final sweep of the prior TI.

For each subsequent sweep, s > 1, calculate E = Zi Pi Oi + S where Pi, Oi are the relevant turn percentages from feeder link, i, and its total outflow (possibly metered) over this TI; S is the total source flow (possibly metered) during the current TI.

Set iteration counter, n = 0, k = ko, and E = Eo.

2. Calculate v (k) such that k < 130 using the analytical representations of the fundamental diagram.

Qmnax(TI) (

Calculate Cap =

0 (G/c) LN,in vehicles, this value may be reduced due to metering SetR= 1.0ifG/c<1 orifk<kc; Set R=0.9onlyifG/C= land k>kc Calculate queue length, Lb = Qbv LL

3. Calculate tj =TI-- L If t1 <0, sett = E1 =O = 0 ; Else, E1 = E t*

v TI

4. Then E2=E-E, ; t 2 =TI-tj
5. If Qb Cap, then OQ = Cap,OM = OE = 0 If tj > 0,then Qe = Qb + Mb + E1 - Cap Else Qe = Qb - Cap End if Calculate Qe and Me using Algorithm A (below)
6. Else (Qb < Cap)

OQ = Qb, RCap = Cap-OQ

7.

If Mb < RCap,then Braidwood Generating Station C-9 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

8.

If t1 > 0, OM = Mb,OE = min RCap - Mb,-----ap 0

Q'e = El -0CI If Q' > 0,then Calculate Qe, Me with Algorithm A Else Qe = 0, Me = E2 End if Else (t, = 0)

OM (v(TI)-Lb Mb and OE 0

OM L--\\

L b

an)O-Me= Mb -

OM + E; Qe = 0 End if

9.

Else (Mb > RCap)

E= 0 If tl>O, then OM=RCap, Qe=Mb--OM+El Calculate Qe and Me using Algorithm A

10.

Else (t, = 0)

Md = [v(TO)-Lb) b K\\

L-Lb )

b]

If Md > RCap, then Om= RCap Qe =Md - OM Apply Algorithm A to calculate Qe and Me Else OM = Md Me= Mb -

OM + E and Qe =0 End if End if End if End if

11. Calculate a new estimate of average density, kn

[kb + 2 km + kel, 4

where kb = density at the beginning of the TI ke = density at the end of the TI km = density at the mid-point of the TI All values of density apply only to the moving vehicles.

If 1kn - kn-1I >E* and n < N where N = max number of iterations, and E is a convergence criterion, then Braidwood Generating Station C-10 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

12.

set n = n + 1, and return to step 2 to perform iteration, n, using k = kn

  • End if Computation of unit problem is now complete. Check for excessive inflow causing spillback.
13. If Qe + Me > (L-W) LN then L,

(L-W) -LN The number of excess vehicles that cause spillback is:

SB = Qe + Me L-W).,N where W is the width of the upstream intersection. To prevent spillback, meter the outflow from the feeder approaches and from the source flow, S, during this TI by the amount, SB. That is, set SB M = 1 -

> 0, where M is the metering factor (over all movements).

(E + S) -

This metering factor is assigned appropriately to all feeder links and to the source flow, to be applied during the next network sweep, discussed later.

Algorithm A This analysis addresses the flow environment over a TI during which moving vehicles can join a standing or discharging queue. For the case Qb Qe

shown, Qb
  • Cap, with t, > 0 and a queue of Qe length, Qe, formed by that portion of Mb and E I

that reaches the stop-bar within the TI, but could v

+

not discharge due to inadequate capacity. That is, Mb Qb+-Mb+E > Cap.

This queue

length, V

L3Qe

= Qb + Mb + El - Cap can be extended to Qe by traffic entering the approach during the current IF ITI, traveling at speed, v, and reaching the rear of the 4

t3 0_11queue within the TI. A portion of the entering T I vehicles, E3 = E will likely join the queue. This analysis calculates t 3, Qe and Me for the input values of L, TI, v, E, t, Lv, LN, Qe.

When t, > 0 and Qb :5 Cap:

Lv Lv

= L" From the sketch, L3 = v(TI - t, - t3) = L -

(Qe + E3) LN Substituting E3 = L3 E yields: -

Vt 3 + L' E L_ = L - v(TI - t1 ) -

L'e. Recognizing that TI TI LN the first two terms on the right hand side cancel, solve for t 3 to obtain:

Braidwood Generating Station C-11 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

t 3 = [

ELv such that 0 5t 3 _TI-tj If the denominator, v

-L 0<, set t 3 = TI - t.

L TI LNJ Then, Qe =Q+E t3 Me=E 1

.. ti +t 3

)

The complete Algorithm A considers all flow scenarios; space limitation precludes its inclusion, here.

C.1.3 Lane Assignment The "unit problem" is solved for each turn movement on each link. Therefore it is necessary to calculate a value, LNx, of allocated lanes for each movement, x. If in fact all lanes are specified by, say, arrows painted on the pavement, either as full lanes or as lanes within a turn bay, then the problem is fully defined. If however there remain un-channelized lanes on a link, then an analysis is undertaken to subdivide the number of these physical lanes into turn movement specific virtual lanes, LN,.

C.2 Implementation C.2.1 Computational Procedure The computational procedure for this model is shown in the form of a flow diagram as Figure C-4. As discussed earlier, the simulation model processes traffic flow for each link independently over TI that the analyst specifies; it is usually 60 seconds or longer. The first step is to execute an algorithm to define the sequence in which the network links are processed so that as many links as possible are processed after their feeder links are processed, within the same network sweep. Since a general network will have many closed loops, it is not possible to guarantee that every link processed will have all of its feeder links processed earlier.

The processing then continues as a succession of time steps of duration, TI, until the simulation is completed. Within each time step, the processing performs a series of "sweeps" over all network links; this is necessary to ensure that the traffic flow is synchronous over the entire network. Specifically, the sweep ensures continuity of flow among all the network links; in the context of this model, this means that the values of E, M, and S are all defined for each link such that they represent the synchronous movement of traffic from each link to all of its outbound links. These sweeps also serve to compute the metering rates that control spillback.

Within each sweep, processing solves the "unit problem" for each turn movement on each link.

With the turn movement percentages for each link provided by the DTRAD model, an algorithm allocates the number of lanes to each movement serviced on each link. The timing at a signal, if any, applied at the downstream end of the link, is expressed as a G/C ratio, the signal timing needed to define this ratio is an input requirement for the model. The model also has the Braidwood Generating Station C-12 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

capability of representing, with macroscopic fidelity, the actions of actuated signals responding to the time-varying competing demands on the approaches to the intersection.

The solution of the unit problem yields the values of the number of vehicles, 0, that discharge from the link over the time interval and the number of vehicles that remain on the link at the end of the time interval as stratified by queued and moving vehicles:

Qe and Me.

The procedure considers each movement separately (multi-piping). After all network links are processed for a given network sweep, the updated consistent values of entering flows, E; metering rates, M; and source flows, S are defined so as to satisfy the "no spillback" condition.

The procedure then performs the unit problem solutions for all network links during the following sweep.

Experience has shown that the system converges (i.e. the values of E, M and S "settle down" for all network links) in just two sweeps if the network is entirely under-saturated or in four sweeps in the presence of extensive congestion with link spillback. (The initial sweep over each link uses the final values of E and M, of the prior TI). At the completion of the final sweep for a TI, the procedure computes and stores all measures of effectiveness for each link and turn movement for output purposes. It then prepares for the following time interval by defining the values of Qb and Mb for the start of the next TI as being those values of Qe and Me at the end of the prior TI. In this manner, the simulation model processes the traffic flow over time until the end of the run. Note that there is no space-discretization other than the specification of network links.

c-13 KLD Engineering, P.c.

Braidwood Generating Station Evacuation Time Estimate C-13 KLD Engineering, P.C.

Rev. 0

Figure C-4. Flow of Simulation Processing (See Glossary: Table C-3)

Braidwood Generating Station Evacuation Time Estimate C-14 KLD Engineering, P.C.

Rev. 0

C.2.2 Interfacing with Dynamic Traffic Assignment (DTRAD)

The DYNEV II system reflects NRC guidance that evacuees will seek to travel in a general direction away from the location of the hazardous event. Thus, an algorithm was developed to identify an appropriate set of destination nodes for each origin based on its location and on the expected direction of travel. This algorithm also supports the DTRAD model in dynamically varying the Trip Table (O-D matrix) over time from one DTRAD session to the next.

Figure B-1 depicts the interaction of the simulation model with the DTRAD model in the DYNEV II system. As indicated, DYNEV II performs a succession of DTRAD "sessions"; each such session computes the turn link percentages for each link that remain constant for the session duration,

[To,,T2], specified by the analyst. The end product is the assignment of traffic volumes from each origin to paths connecting it with its destinations in such a way as to minimize the network-wide cost function. The output of the DTRAD model is a set of updated link turn percentages which represent this assignment of traffic.

As indicated in Figure B-i, the simulation model supports the DTRAD session by providing it with operational link MOE that are needed by the path choice model and included in the DTRAD cost function. These MOE represent the operational state of the network at a time, T1 _< T2, which lies within the session duration, [To, T2]. This "burn time", T1 - To, is selected by the analyst. For each DTRAD iteration, the simulation model computes the change in network operations over this burn time using the latest set of link turn percentages computed by the DTRAD model. Upon convergence of the DTRAD iterative procedure, the simulation model accepts the latest turn percentages provided by the DTA model, returns to the origin time, To, and executes until it arrives at the end of the DTRAD session duration at time, T2. At this time the next DTA session is launched and the whole process repeats until the end of the DYNEV II run.

Additional details are presented in Appendix B.

Braidwood Generating Station C-15 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

APPENDIX D Detailed Description of Study Procedure

D. DETAILED DESCRIPTION OF STUDY PROCEDURE This appendix describes the activities that were performed to compute Evacuation Time Estimates. The individual steps of this effort are represented as a flow diagram in Figure D-1.

Each numbered step in the description that follows corresponds to the numbered element in the flow diagram.

Step 1 The first activity was to obtain EPZ boundary information and create a GIS base map. The base map extends beyond the Shadow Region which extends approximately 15 miles (radially) from the power plant location. The base map incorporates the local roadway topology, a suitable topographic background and the EPZ boundary.

Step 2 2010 Census block information was obtained in GIS format. This information was used to estimate the resident population within the EPZ and Shadow Region and to define the spatial distribution and demographic characteristics of the population within the study area. Transient, employment, and special facility data were obtained from Exelon and the offsite agencies.

Step 3 Next, a physical survey of the roadway system in the study area was conducted to determine the geometric properties of the highway sections, the channelization of lanes on each section of roadway, whether there are any turn restrictions or special treatment of traffic at intersections, the type and functioning of traffic control devices, gathering signal timings for pre-timed traffic signals, and to make the necessary observations needed to estimate realistic values of roadway capacity.

Step 4 The results of a telephone survey of households within the EPZ were obtained from Exelon to identify household

dynamics, trip generation characteristics, and evacuation-related demographic information of the EPZ population. This information was used to determine important study factors including the average number of evacuating vehicles used by each household, and the time required to perform pre-evacuation mobilization activities.

Step 5 A computerized representation of the physical roadway system, called a link-node analysis network, was developed using the UNITES software (see Section 1.3) developed by KLD. Once the geometry of the network was completed, the network was calibrated using the information gathered during the road survey (Step 3). Estimates of highway capacity for each link and other link-specific characteristics were introduced to the network description. Traffic signal timings were input accordingly. The link-node analysis network was imported into a GIS map. 2010 Census data were overlaid in the map, and origin centroids where trips would be generated during the evacuation process were assigned to appropriate links.

Braidwood Generating Station D-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Step 6 The EPZ is subdivided into 16 Sub-areas. Based on wind direction and speed, Regions (groupings of Sub-areas) that may be advised to evacuate, were developed.

The need for evacuation can occur over a range of time-of-day, day-of-week, seasonal and weather-related conditions. Scenarios were developed to capture the variation in evacuation demand, highway capacity and mobilization time, for different time of day, day of the week, time of year, and weather conditions.

Step 7 The input stream for the DYNEV II model, which integrates the dynamic traffic assignment and distribution model, DTRAD, with the evacuation simulation model, was created for a prototype evacuation case - the evacuation of the entire EPZ for a representative scenario.

Step 8 After creating this input stream, the DYNEV II System was executed on the prototype evacuation case to compute evacuating traffic routing patterns consistent with the appropriate NRC guidelines. DYNEV II contains an extensive suite of data diagnostics which check the completeness and consistency of the input data specified. The analyst reviews all warning and error messages produced by the model and then corrects the database to create an input stream that properly executes to completion.

The model assigns destinations to all origin centroids consistent with a (general) radial evacuation of the EPZ and Shadow Region. The analyst may optionally supplement and/or replace these model-assigned destinations, based on professional judgment, after studying the topology of the analysis highway network.

The model produces link and network-wide measures of effectiveness as well as estimates of evacuation time.

Step 9 The results generated by the prototype evacuation case are critically examined. The examination includes observing the animated graphics (using the EVAN software which operates on data produced by DYNEV II) and reviewing the statistics output by the model. This is a labor-intensive activity, requiring the direct participation of skilled engineers who possess the necessary practical experience to interpret the results and to determine the causes of any problems reflected in the results.

Essentially, the approach is to identify those bottlenecks in the network that represent locations where congested conditions are pronounced and to identify the cause of this congestion. This cause can take many forms, either as excess demand due to high rates of trip generation, improper routing, a shortfall of capacity, or as a quantitative flaw in the way the physical system was represented in the input stream. This examination leads to one of two conclusions:

The results are satisfactory; or The input stream must be modified accordingly.

Braidwood Generating Station D-2 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

This decision requires, of course, the application of the user's judgment and experience based upon the results obtained in previous applications of the model and a comparison of the results of the latest prototype evacuation case iteration with the previous ones.

If the results are satisfactory in the opinion of the user, then the process continues with Step 13. Otherwise, proceed to Step 11.

Step 10 There are many "treatments" available to the user in resolving apparent problems.

These treatments range from decisions to reroute the traffic by assigning additional evacuation destinations for one or more sources, imposing turn restrictions where they can produce significant improvements in capacity, changing the control treatment at critical intersections so as to provide improved service for one or more movements, or in prescribing specific treatments for channelizing the flow so as to expedite the movement of traffic along major roadway systems. Such "treatments" take the form of modifications to the original prototype evacuation case input stream. All treatments are designed to improve the representation of evacuation behavior.

Step 11 As noted above, the changes to the input stream must be implemented to reflect the modifications undertaken in Step 10. At the completion of this activity, the process returns to Step 9 where the DYNEV II System is again executed.

Step 12 Evacuation of transit-dependent evacuees and special facilities are included in the evacuation analysis. Fixed routing for transit buses and for school buses, ambulances, and other transit vehicles are introduced into the final prototype evacuation case data set. DYNEV II generates route-specific speeds over time for use in the estimation of evacuation times for the transit dependent and special facility population groups.

Step 13 The prototype evacuation case was used as the basis for generating all region and scenario-specific evacuation cases to be simulated. This process was automated through the UNITES user interface. For each specific case, the population to be evacuated, the trip generation distributions, the highway capacity and speeds, and other factors are adjusted to produce a customized case-specific data set.

Step 14 All evacuation cases are executed using the DYNEV II System to compute ETE. Once results are available, quality control procedures are used to assure the results are consistent, dynamic routing is reasonable, and traffic congestion/bottlenecks are addressed properly.

Braidwood Generating Station D-3 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Step 15 Once vehicular evacuation results are accepted, average travel speeds for transit and special facility routes are used to compute evacuation time estimates for transit-dependent permanent residents, schools, hospitals, and other special facilities.

Step 16 The simulation results are analyzed, tabulated and graphed.

The results were then documented, as required by NUREG/CR-7002.

Step 17 Following the completion of documentation activities, the ETE criteria checklist (see Appendix N) was completed. An appropriate report reference is provided for each criterion provided in the checklist.

Braidwood Generating Station Evacuation Time Estimate D-4 KLD Engineering, P.C.

Rev. 0

Step 1 Create GIS Base Map 4'

Step 2 Step 9 Examine Prototype Evacuation Case using EVAN and DYNEV 11 Output Results Satisfactory Step 10 I

Gather Census Block and Demographic Data for Study Area Step 3 I

Field Survey of Roadways within Study Area 1Step 4

Analyze Telephone Survey and Develo ri Generation Characteristics TStep 5

SCreate and Calibrate Link-Node AnalysiNewr F-Step 6 Develop Evacuation Regions and Scenarios Step 7 Create and Debug DYNEV-11 Input Stream Modify Evacuation Destinations and/or Develop Traffic Control Treatments Step 11 Modify Database to Reflect Changes to Prototype Evacuation Case Step 12 Establish Transit and Special Facility Evacuation Routes and Update DYNEV-11 Database IStep 13 Generate DYNEV-11 Input Streams for All Evacuation Cases Step 14 Use DYNEV-11 Average Speed Output to Compute ETE for Transit and Special Facility Routes IStep 15 Use DYNEV-11 Results to Estimate Transit and Special Facilities Evacuation Time Estimates IStep 16 I

Documentation Step 17 F

Complete ETE Criteria Checklist IStep 8

I Execute DYNEV II for Prototype Evacuation Case Figure D-1. Flow Diagram of Activities Braidwood Generating Station Evacuation Time Estimate D-5 KLD Engineering, P.C.

Rev. 0

APPENDIX E Special Facility Data

E. SPECIAL FACILITY DATA The following tables list population information, as of April 2014, for special facilities, recreational areas and major employers that are located within the EPZ. Special facilities are defined as schools, preschools, day camps, and medical facilities. Transient population data is included in the tables for recreational areas and lodging facilities. Employment data is included in the table for major employers. Each table is grouped by county. The location of the facility is defined by its straight-line distance (miles) and direction (magnetic bearing) from the center point of the plant. Maps of each school, preschool, day camp, medical facility, recreational area, lodging facility, and major employer are also provided.

Braidwood Generating Station Evacuation Time Estimate E-1 KLD Engineering, P.C.

Rev. 0

Table E-1. Schools within the EPZ Su-Ditnce~

IDareceIEnrollP area (mil~EEE~Ees ion Scool Nme Steet AdressMunicpalit ment Staf 7

4.5 NW Coal City Elementary School 300 North Broadway St.

Coal City 328 36 10 2.2 WSW Braceville Elementary School 209 North Mitchell St.

Braceville 176 20 10 4.8 NW Coal City High School 655 West Division St.

Coal City 652 72 10 4.0 NW Coal City Intermediate School 305 East Division St.

Coal City 315 35 10 4.6 WNW Coal City Middle School 500 South Carbon Hill Rd.

Coal City 488 54 12 10.5 W

M.V.K. Elementary School 1013 North St.

Mazon 189 23 12 10.5 W

M.V.K. Middle School 1013 North St.

Mazon 149 18 South 14 5.4 SSW South Wilmington Grade School 375 Fifth Ave.

Wilmington 89 11 15 5.3 SW Gardner Elementary School 598 North Elm St.

Gardner 228 28 15 5.6 SW Gardner/South Wilmington High School 500 East Main St.

Gardner 209 26 Shadow Region' 14.5 NW White Oak Elementary 2001 Duponte Ave.

Morris 842 94 9

10.2 S

Reddick Grade School 210 East Main Reddick 119 25 Will County,llni 1

1.5 NE Reed-Custer High School 249 Comet Dr.

Braidwood 595 66 1

1.4 NNE Reed-Custer Intermediate School 162 South School St.

Braidwood 508 61 1

1.4 NE Reed-Custer Middle School 407 Comet Dr.

Braidwood 391 43 5

6.1 NE L.J. Stevens Intermediate School 221 Ryan St.

Wilmington 400 44 5

6.1 NE St. Rose School 626 South Kankakee St.

Wilmington 144 16 5

5.9 NE Trinity Services Island City 1197 South Buchanan St.

Wilmington 25 3

5 6.4 NE Wilmington High School 209 Wildcat Court Wilmington 474 57 Although Shadow Region facilities are located outside the EPZ, they are listed in county and/or state emergency plans.

E-2 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate E-2 KLD Engineering, P.C.

Rev. 0

6.2 NE~Wilmington Middle School 715 South Joliet St.Wlmntn 304 1

13 1

5.3 1 ENE I Bruning Elementary School 1 1910 Bruning Dr.

I Wilmington 1

251 1

28 1

13 5.2 E

Reed-Custer Prim E-3 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate E-3 KLD Engineering, P.C.

Rev. 0

Table E-2. Preschools and Day Camps within the EPZ Ditac -

ir-Enol Sub-rea (mils) ion chol Nae SreetAddess uniipalty ent taf GrnyCony Ilini 4

8.2 NW Boy Scouts of America (Day Camp) 2600 North Winterbottom Rd.

Morris 1,000 N/A 8

12.3 WNW Rainbow Preschool 455 West Southmore Rd.

Morris 38 7

10 4.3 WNW Coal City Early Childhood Center 755 South Carbon Hill Rd.

Coal City 351 39 10 4.5 NW Kid's Korner 405 West Division Coal City 24 5

10 3.5 NNW Step by Step Child Care Center - Diamond 185 South Berta Rd.

Diamond 103 17 Wil ConyIlni 1

1.1 SW Godley Park District Child Care Center 500 South Kankakee St.

Godley 102 18 1

1.8 NNW Shepherd's Flock Pre-School 1180 West First St.

Braidwood 30 5

1 1.0 N

Step by Step Child Care Center - Braidwood 306 South Division St.

Braidwood 129 18 5

5.9 NE Discovery Schoolhouse 201 East Kahler Rd.

Wilmington 37 7

5 6.1 Grace Lutheran Preschool 907 Luther Dr.

Wilmington 30 6

N/A = Staff data not provided Table E-3. Medical Facilities within the EPZ WILL~

CONT Island City Rehab Center (Formerly 555 West 5

5.6 NE Embassy Care Center)

Kahler Road Wilmington 171 129 64 53 12 E-4 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate E-4 KLD Engineering, P.C.

Rev. 0

Table E-4. Employers within the EPZ 4

1u.z NNW uresoen Lenerating tation bbUU Norrn uresaen Ka.

Morris Z125 I O.Z$o I

.11 4

10.6 NNW Forbo Adhesives 6352 East Collins Rd.

Morris Not a major employer 4

9.8 NNW Morris Operation - G.E. Company East Collins Rd.

Morris 4

10.5 NNW Reichold Chemical Inc.

East Collins Rd.

Morris 65 63.3%

42 4

10.6 NNW Technical Propellant East Collins Rd.

Morris Not a major employer 7

4.2 NNW Chicago Aerosols, LLC 1300 East North St.

Coal City 60 63.3%

38 7

4.3 NNW Evron Industries 1300 East North St.

Coal City 70 63.3%

45 12 9.9 W

ITW Filtration 804 Commercial Dr.

Mazon 50 63.3%

32 14 5.3 SW F&J Metals 113 South State Route 53 Gardner 55 63.3%

35 15 6.1 SW Brownie Special Products Co.

423 Industry Ave.

Gardner Not a major employer 15 6.7 SW Dibble Trucking 7505 South Route 66 Gardner 9

8.0 EE NDY Manufacturing Inc.

4590 North 11000 West Rd.

Bonfield N tamj re poe 9

10.3 SE Van Voorst Lumber Co.

1 Center St.

Union Hill Ntamjrepoe 1

SW Braidwood Generating Station 35100 Illinois 53 Braceville 774 63.3%

490 1

2.5 ESE Exelon Training Center 36400 South Essex Rd.

Wilmington 175 63.3%

111 1

1.0 SW Godley Park District 500 South Kankakee St.

Godley Not a major employer 5

7.1 NE Dow Chemical Co.

901 Kankakee River Rd.

Wilmington 120 63.3%

76 5

5.8 NE Precision Components, Inc.

400 Davy Ln.

Wilmington 65 63.3%

42 5

5.9 NE Trinity Services Island City 1197 South Buchanan St.

Wilmington 65 63.3%

42 5

7.1 NE United States Cold Storage 800 East Kankakee River Dr.

Wilmington 50 63.3%

32 5

6.4 NE Wilmington School District 209 Wildcat Court Wilmington 100 63.3%

64 13 9.3 NE Illinois Transport Inc.

20012 West South Arsenal Rd.

Wilmington Not a major employer 13 9.9 NE Local 150 Operating Engineers 19800 West Arsenal Rd.

Wilmington 60 63.3%

38 KIP2Fd Arm~

ncnrxi Trninina rnntmr

'Arnln Arctnnni QA4 ItAf~f iAn rI i oL E-5 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate E-5 KLD Engineering, P.C.

Rev. 0

Table E-5. Recreational Areas within the EPZ 4

9.0 NW IGoose Lake Prairie State Park 5010 North Jugtown Rd.

Morris 30 13 4

9.8 NNW Heidecke Lake State Fish and Wildlife Area 5010 County Road 5000 East Morris 134 55 7

5.9 NNW CECO Recreation Club Dresden Rd.

Wilmington 450 185 7

5.4 NW Coal City Area Club 1500 North Broadway Rd.

Coal City 400 164 10 3.5 SW Mazonia State Fish & Wildlife Area IL-53 & Hudson Rd.

Braceville 2,500 1,025 14 5.2 SSW South Wilmington Fireman's Club 7019 East Rice Rd.

South Wilmington 655 269 1

3.1 SSE High Point Golf Club S309 Highpoint Dr.

WEssex 27131

,12 S

N Braidwood Dunes & Savannah Forest Preserve Route 113 & Essex Rd.

Braidwood 5

3 2

4.4 E

Braidwood Fairways Golf Course 35504 Essex Rd.

Wilmington 60 25 2

4.3 NE Braidwood Recreational Club 25000 Illinois 113 Braidwood 1,440 591 1

W Godley Park District 500 South Kankakee St.

Godley 50 21 S

NNE Shadow Lakes Association Inc.

24727 Amenity Center Dr.

Wilmington 1,076 441 S

4.

ESouth Wilmington Sportsman's Club 24628 County Line Rd.

Wilmington 3,000 1,230 3

3.5 N

Area # 1 Outdoor Club Frontage Rd.

Boal City 100 41 S

SE Cinder Ridge Golf Course 24801 Lakepoint Dr.

Wilmington 97 40 S

3 NE Fossil Rock Recreation Area 24615 West Stripmine Rd.

Wilmington 968 397 2

8.9 N

Lake Point Club 24801 Lakepoint Dr.

Wilmington 1,080 443 5

6.6 NNE Tameling Campground 32100 S State Route 129 Wilmington 98 41 2 48 NEWill County Sportsmen's Club 23743 Stripmine Rd.

Wilmington 200 82 3

ENew Lenox Sportsmen's Club US Route 53 EBraidwood 300 123 3

ETammen Treeberry Farm 37131 Essex Rd.

Wilmington 1,200 492 3

EWilmington Recreation Area Club 33915 S State Route 53 Braidwood 450 185 5 89 N

Des Plaines Conservation Area 24621 North River Rd.

Wilmington 366 150 5 66 NEDes Plaines Game Propagation Center 30550 S. Boathouse Rd.

Wimnton 20 9

Braidwood Generating Station Evacuation Time Estimate E-6 KLD Engineering, P.C.

Rev. 0

5 1 6.0 1 NE Wilmington Island Park District 1147 North Park St.

tWilmington 1

500 1

205 13 1 6.7 1 NE IForsythe Woods Forest Preserve East Kahler Rd.

Wilmington 182 75 1

13 1 10.9 1 ESE IKankakee River S Table E-6. Lodging Facilities within the EPZ 1

1.6 NN B uraiawool Motel 12U Nortfl Waslnington St.

Braiawooa lb 1

1.3 NW Sands Motel 1179 West Kennedy Rd.

Braidwood 60 30 1

1.5 NNW Sun Motel 140 South Hickory St.

Braidwood 90 45 2

7.3 NNE Knight's Inn Motel 24001 Lorenzo Rd.

Wilmington 68 34 5

6.1 Van Duynes Motel 107 Bridge St.

Wilmington 24 12 Table E-7. Correctional Facilities within the EPZ Sub DitneDrc ma are (mls o

Failt Nam Stree Adrs Muiiplty ct Wil ConyIlni I

13 I

11.1 I

E I Kankakee Minimum Security Unit OFFICIALLY CLOSED 2 2 The Kankakee Minimum Security Unit officially closed in April of 2010.

Braidwood Generating Station Evacuation Time Estimate E-7 KLD Engineering, P.C.

Rev. 0

9 2OVS hanflahon Eloo Sub-arec4 8

Sub-Aare~a 2

Sub-area: 7-Is8 HYIIs 6! Coal Br idwoodak WiSyrngton\\

9 Manhattan Sub-area: 13 4

Verona j

{zon Sub-area: 12 47 Sub-arel: 11 Sub-area: 10O 8\\

1 7 N

't Brast'-

gton Brooklyn ISub-rek I Sub-ara:

16 lo No.

1 Braceville Elementary School I_

2 Brunino Elementary School Cool City ElementarySchool Faclifty Name 4

Coat City High School So Wilmi

/

/

I

-oa4 C.rt intermeoiate Scnool Essex f"

Sub-area: 6

-Miles--

'47 Legend BWD

=

School I

Sub-area 2, S, 10 Mile Rings Sub-area: 14 Sub-arel: 16 Sub-area: 15 4-

~Sub-rea: 9

,/

a 4.Union dick Rdic" Hill 12 4054a/WZ4 1

cons.ESý -.

6 Coal City Middle School 7 Gardner Elementary School 8 Gardner/South Wilmington High School 9

UI. Stevens Intermediate School 10 MVK. Elementary School 11 M.V.K. Middle School 12 Reddick Grade School 13 Reed-Custer High School 14 Reed-Custer Intermediate School 15 Reed-Custer Middle School 16 Reed-custer Primary School 17 South Wilmington Grade School 18 St. Rose School 19 Trinity Services Island City 20 White Oak Elementary 21 Wiimington High School 22 1 Wilmln.ton Middle School 5

10 Miles Figure E-1. Schools within the BWD EPZ E-8 KLD Engineering, P.C.

Braidwood Generating Station Evacuation Time Estimate E-8 KLD Engineering, P.C.

Rev. 0

Figure E-2. Preschools and Day Camps within the BWD EPZ Braidwood Generating Station Evacuation Time Estimate E-9 KLD Engineering, P.C.

E-9 KLD Engineering, P.C.

Rev. 0

I7 Figure E-3. Medical and Correctional Facilities within the BWD EPZ Braidwood Generating Station E-1K Evacuation Time Estimate KLD Engineering, P.C.

Rev. 0

Map No.

1 2

3 4

5 6

7 8

Facillty Name Army Reserve Tra inirg Center Braidwood Generating Station Brownie Special Products Co.

Chicago Aerosols, LLC Dibble Trucking Dow Chemical Co.

Dresden Generating Station Evron Industries

__ I.

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Exelon TrainingCenter F&J Metals Forbo Adhesives Godley Park District Illinois Transport Inc.

ITW Filtration Local 150 Operating Engineers Morris Operation -G.E. Compan NDY Manufacturing Inc, Precision Components, Inc.

Reichold Chemical Inc.

Technical Propellant Trinity Services Island City United States Cold Storage Van Voorst Lumber Co.

Wilmington ScholV District Verona

...1 S Mul........

,ooai

-1 uhannehSy JeLo n

a n

/n ub-area

73'4 Subrea

/

/4 Sub-area: 8 Wim$bgtan

/ I

/

r "

i

  • woo

\\

14

-I Su rCiOty I)

Adaron 2

Esx Sub-aa 6

\\

/

5 Wil ington Brooklyn S"Mlles*

4 2

city1au-a:

Sub-rara 1

l Su-aea 12-=.

ey

/

oi Gard or;;. oi 17*

to 1'~

It,insman Legend BWD Employer Major Employer Sub-area

,. 2,5, 10 Mile Rings I ( Olnll*J Figure E-4. Employers within the BWD EPZ Braidwood Generating Station Evacuation Time Estimate E-11 KLD Engineering, P.C.

Rev. 0

10 Channahon

- 10 Channaho Moareas Sub-ama: 5 Sub-ama: 8 Sub-area: 7SubaraI a Sub-area: 2 F

Tl 7

18 C=) /

Carbo,. "

1 a ULj Hill r

i 12*

Coa map NO.I Facility Name, Elwood Wilmingto L

1 Area #1 Outdoor Club 2 Braldwood Dunes & Savannah Forest Preserve 3 Braidwood Fa irways Golf Course 4 Braldwood Recreational Club 5

CECO Recrea.tion Club 6Cinder Ridge GolffCourse 7CoalI City Area Club 8 Des Plaines Conservation Area 9 Des Plaines Game Propagation Center 10 Dresden Island Lock& Dam U..

r........................

111 Forsythe Woods Forest Preserve 12 1Fossil Rock Recreation Area Mazonl Sub-area: 12 I

Sub-arel: 11

/

Sub-areal 10 Bracei 1 a 19

-7 I,

  • Surarei 11

-23

.U 2

1 Sub-area: 3 125

/

Sub-ar

/

24 TamelinoCamoaround 13 Godley Park District 14 Goose Lake Prairie State Park 15 Heidecke Lake State Fish and Wildlife Area 16 High Point GolfClub 17 Ka nkakee River Sta te Park 18 Lake Point Club 19 Mazonia State Fish & Wildlife Area 20_ New Lenox Sportsmen's Club 21 Shadow Lakes ReAssociation Inc.

22 South Wilmington Fireman's Club 23 South Wilmington Sportsman's Club Verona ala: 13 Legend BWu

]

Campground Golf Hunting / Fishing Other I

Park IJ Sub-area 2, S, 10 Mile Rings Grner E

,,x Sub-area: 6

'5 22 East '~

Brooklyn f~

Sub-area" 16 Sub-area: 15 Sub-area: 14

/

Sub-area: 9

/

Bonfield

/

Limestone 17 17 S1MHill 0si 5

10 j1Re di k_

Coenrieir [SRI~e,n Miles I

an i e..efl. Eiyr, G.e.,.(oe Figure E-5. Recreational Areas within the BWD EPZ E-12 KLD Engineering, P.c, Braidwood Generating Station Evacuation Time Estimate E-12 KLD Engineering, P.C.

Rev. 0

Figure E-6. Lodging Facilities within the BWD EPZ Braidwood Generating Station Evacuation Time Estimate E-13 KLD Engineering, P.C.

Rev. 0

APPENDIX F Telephone Survey

F. TELEPHONE SURVEY F.1 Introduction The development of evacuation time estimates for the BWD EPZ requires the identification of travel patterns, car ownership and household size of the population within the EPZ.

Demographic information can be obtained from Census data. The use of this data has several limitations when applied to emergency planning. First, the Census data do not encompass the range of information needed to identify the time required for preliminary activities (mobilization) that must be undertaken prior to evacuating the area. Secondly, Census data do not contain attitudinal responses needed from the population of the EPZ and consequently may not accurately represent the anticipated behavioral characteristics of the evacuating populace.

These concerns are addressed by conducting a telephone survey of a representative sample of the EPZ population. The survey is designed to elicit information from the public concerning family demographics and estimates of response times to well defined events. The design of the survey includes a limited number of questions of the form "What would you do if...?" and other questions regarding activities with which the respondent is familiar ("How long does it take you to...?")

Attachment A presents the final survey instrument used in this study. A sample size of 384 completed survey forms yields results with a sampling error of +/-5% at the 95% confidence level. The sample must be drawn from the EPZ population.

The preliminary determination of whether a household was located inside the EPZ was based on "land-line" telephone listings with street addresses. Telephone surveys were then conducted using those numbers, selected in random order, until the target level of surveys was completed, or the entire calling list was exhausted. Rejections or households outside the EPZ were discarded. Numbers with "no answer" were re-cycled for up to ten attempts in different time windows.

F.2 Survey Results The results of the survey fall into two categories. First, the household demographics of the area can be identified. Demographic information includes such factors as household size, automobile ownership, and automobile availability. The distributions of the time to perform certain pre-evacuation activities are the second category of survey results. These data are processed to develop the trip generation distributions used in the evacuation modeling effort, as discussed in Section 5.

A review of the survey instrument reveals that several questions have a "don't know" (DK) or "refused" entry for a response. It is accepted practice in conducting surveys of this type to accept the answers of a respondent who offers a DK response for a few questions or who refuses to answer a few questions. To address the issue of occasional DK/refused responses from a large sample, the practice is to assume that the distribution of these responses is the same as the underlying distribution of the positive responses. In effect, the DK/refused responses are ignored and the distributions are based upon the positive data that is acquired.

Braidwood Generating Station F-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

F.2.1 Household Demographic Results Household Size Figure F-1 presents the distribution of household size within the EPZ. The average household contains 2.40 people.

[-Household Size 03 0

0 C

60%

50%

40%

30%

20%

10%

0%IF 2

3 People 5

6+

1 4

Figure F-2. Household Size in the EPZ Automobile Ownership The average number of automobiles available per household in the EPZ is 2.11. Approximately 3.1% of households do not have a vehicle available, as shown in Figure F-2.

Vehicle Availability IA 02 03 0

50%

40%

30%

20%

10%

0%

5 6

7 i

0 1

2 3

4 Vehicles 5

6 7

Figure F-2. Household Vehicle Availability Braidwood Generating Station Evacuation Time Estimate F-2 KLD Engineering, P.C.

Rev. 0

Commuters Figure F-3 presents the distribution of the number of commuters in each household.

Commuters are defined as household members who travel to work or college on a daily basis.

The data shows an average of 0.91 commuters in each household in the EPZ, and 52% of households have at least one commuter.

Commuters Per Household 60%

.* 50%

40%

0Z 30%

0 S20%

t 10%

4--

0% -

0 1245 2

Commuters 3

4 5

Figure F-3. Commuters in Households in the EPZ Braidwood Generating Station Evacuation Time Estimate F-3 KLD Engineering, P.C.

Rev. 0

F.2.2 Evacuation Response Questions were asked to gauge the population's response to an emergency. These are now discussed:

"How many vehicles would your household take if an evacuation were ordered when all household members were at home??" The response is shown in Figure F-4. On average, evacuating households would use 1.32 vehicles.

Evacuating Vehicles Per Household 0

0 U

80%

70%

60%

50%

40%

30%

20%

10%

0%

m*

I 1

2 Vehicles 3

4 Figure F-4. Number of Vehicles Used for Evacuation Braidwood Generating Station Evacuation Time Estimate F-4 KLD Engineering, P.C.

Rev. 0

"If an evacuation notice were given while [the primary commuter] was at work, do you think they would most likely..." The response is shown in Figure F-5. Of the survey participants who responded, 32 percent indicated they would evacuate from work, 40 percent said they would return home first and then evacuate, and 28 percent indicated that they would stay outside the evacuation zone where they work.

Commuter Evacuation Response IA 0

0 U

t,CL 45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

4 4

Evacuate from Work Return Home Stay outside Evacuation Zone Figure F-5. Commuter Evacuation Response Braidwood Generating Station Evacuation Time Estimate F-5 KLD Engineering, P.C.

Rev. 0

F.2.3 Time Distribution Results The survey asked several questions about the amount of time it takes to perform certain pre-evacuation activities. These activities involve actions taken by residents during the course of their day-to-day lives. Thus, the answers fall within the realm of the responder's experience.

The mobilization distributions provided below are the result of having applied the analysis described in Section 5.4.1 on the component activities of the mobilization.

"How long do you think it would take [the primary commuter] to get prepared and actually leave work?" Figure F-6 presents the cumulative distribution; in all cases, the activity is completed within 75 minutes. Eighty-eight percent can leave within 30 minutes.

Time to Prepare to Leave Work EE0 0

100%

80%

60%

40%

20%

0%

0 15 30 45 60 Preparation Time (min) 75 Figure F-6. Time Required to Prepare to Leave Work Braidwood Generating Station Evacuation Time Estimate F-6 KLD Engineering, P.C.

Rev. 0

"About how long does it take [the primary commuter] to get from work to home?" Figure F-7 presents the work to home travel time for the EPZ. Eighty percent of commuters can arrive home within 30 minutes of leaving work; all within 75 minutes.

Work to Home Travel 100%

P 80%

E E 60%

0 40%

U 5 20%

0%

0 15 30 45 60 75 Travel Time (min)

Figure F-7. Work to Home Travel Time Braidwood Generating Station Evacuation Time Estimate KLD Engineering, P.C.

Rev. 0

"if an evacuation were ordered when all household members were at home (for example, at night or on a weekend), approximately how long would it take your household to prepare to depart? Please assume that you are advised to plan to be away from your home for 3 days."

Figure F-8 presents the time required to prepare for leaving on an evacuation trip. In many ways this activity mimics a family's preparation for a short holiday or weekend away from home. Hence, the responses represent the experience of the responder in performing similar activities. Approximately 73 percent of households can be ready to leave home within 40 minutes; the remaining households require up to an additional 80 minutes.

Preparation Time with Everyone Home 100%

  • 2 80%

C, 1A 0X o20%

0%

0 30 60 90 120 Preparation Time (min)

Figure F-8. Time to Prepare Home for Evacuation The survey conducted in support of this study did not ask residents how long it would take them to remove snow from their driveway if there were snow on the ground when an evacuation was ordered. As discussed in Section 5.3, the response to the snow removal question in a survey conducted in 2012 in support of ETE development for the Duane Arnold Energy Center (DAEC) is adapted for this study. DAEC is located in Iowa, 193 miles west-northwest of BWD. It is assumed that snowfall and snow removal times are comparable in both EPZs.

"How long would it take you to clear 6 to 8 inches of snow from your driveway?" During adverse, snowy weather conditions, an additional activity must be performed before residents can depart on the evacuation trip.

Although snow scenarios assume that the roads and highways have been plowed and are passable (albeit at lower speeds and capacities), it may be necessary to clear a private driveway prior to leaving the home so that the vehicle can access the street. Figure F-9 presents the time distribution for removing 6 to 8 inches of snow from a driveway. The time distribution for clearing the driveway has a long tail; about 96 percent of driveways are passable within 60 minutes. The last driveway is cleared two hours after the Braidwood Generating Station F-8 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

start of this activity. Note that those respondents (46%) who answered that they would not take time to clear their driveway were assumed to be ready immediately at the start of this activity. Essentially they would drive through the snow on the driveway to access the roadway and begin their evacuation trip.

Time to Remove Snow from Driveway 0

0 100%

80%

60%

40%

20%

0%

0 15 30 45 60 Time (min) 75 90 105 120 Figure F-9. Time to Clear Driveway of 6V-8" of Snow F.3 Conclusions The telephone survey provides valuable, relevant data associated with the EPZ population, which have been used to quantify demographics specific to the EPZ, and "mobilization time" which can influence evacuation time estimates.

Braidwood Generating Station Evacuation Time Estimate F-9 KLD Engineering, P.C.

Rev. 0

ATTACHMENT A Telephone Survey Instrument Braidwood Generating Station Evacuation Time Estimate F-10 KLD Engineering, P.C.

Rev. 0

Teleohone Survey Instrument Exelon Survey Final v6 - August 23, 2011 INTRODUCTION Hello, my name is and I am calling fiom MDC Research, a public opinion firm. We are conducting a brief survey to gather information from households in your area about emergency response planning, and we'd like to include your opinions. This survey is being conducted on behalf of the (insert facility name) Nuclear Facility, and will take approximately 5 minutes to complete. We are not trying to sell you anything. The information gathered fiom this survey will help local agencies more effectively provide community assistance should an emergency situation arise.

Can I please speak with an adult member of the household?

SCREENER S 1. What is the zip code of your primary residence? This is the home where you live the majority of the time. DO NOT READ ZIP CODE LIST List of appropriate zip codes will be displayed here 99999 Location outside the EPZ - THANK & TERMINATE S2. Which of the following categories best describes your age?

11 Under 18 yrs of age - ASK FOR REFERRAL or THANK & TERMINATE 12 18 to 24 13 25 to 34 14 35 to 44 15 45 to 54 16 55 to 64 17 65 to 74 18 75 or older 98 (DO NOT READ) Refused QUESTIONNAIRE Q I How many people currently reside in your household?

Record:

  1. of residents 98 (DO NOT READ) Refused - THANK & TERMINATE Q2 How many motor vehicles are normally based at your home?

Record:

  1. of vehicles 997 None - SKIP TO Q14 998 (DO NOT READ) Refused Braidwood Generating Station F-11 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Q3 How many members of your household are over the age of 16?

Record:

  1. of residents 998 (DO NOT READ) Refused Q4 How many members of your household are licensed drivers?

Record:

  1. of drivers 998 (DO NOT READ) Refused Q5 How many of the adults in your household work outside the home?

Record ED Skip to Q6A 997 None - Continue to Q5A 998 (DO NOT READ) Refused If refused, explain; The nature of this project is to estimate traffic volumes and flow in the event of an emergency evacuation, so this data is necessary in order for us to continue with the survey.

If still refused - THANK & TERMINATE Q5A (ONLY ASK IF Q5=997) Which of the following best describes the non-working adults in your household? MULTIPLE MENTION - IP NOTE: No more mentions than Q3 mentions.

11 Currently unemployed/actively looking for work 12 Retired 13 On Disability or leave of absence 14 Student/continuing education 15 Homemaker 99 Other - please specify SKIP TO Ql Repeat the following Q6A-F sequence for each working adult cited in Q5 For each of the working adults you just referenced, I'd like to ask a few questions related to what their likely actions would be in the case of an emergency evacuation. I understand that I will be asking you to speculate on what other members of the household may do in this situation, but your best guesses are just fine for our purposes.

Q6A Who is the first working adult in the household that you are thinking about? What is their relationship to you?

1 Self 2 Spouse or significant other 3 Parent of child 4 Other relative or in-law 5 Roommate 6 Boarder 7 Other Braidwood Generating Station F-12 KID Engineering, P.C.

Evacuation Time Estimate Rev. 0

Q6B Which of the following best describes this person's usual work schedule?

1 Monday - Friday, 8:00am to 5:00pm 2 Swing Shift 3 Graveyard 4 Evenings and weekends 5 Rotating shifts 6 Other or irregular schedule 7 (DO NOT READ) Don't know Q6C Does this person generally use a personal vehicle to commute back and forth to work?

1 Yes 2 No 7 (DO NOT READ) Don't know Q6D If an evacuation notice were given while this person was at work, do you think they would most likely...

1 Evacuate directly from work 2 Come home first and then evacuate, or 3 Stay outside the evacuation zone where they work E Skip to Q7 7 (DO NOT READ) Don't know Q6E How long do you think it would take this person to get prepared and actually leave work?

(Read list if necessary) 1 Less than 15 minutes 2 15 to 30 minutes 3 30 to 45 minutes 4 45 to 60 minutes 5 More than 60 minutes 7 (DO NOT READ) Don't know If response at 6D is 1, skip from here to Q7 Q6F About how long does it take this household member to get from work to home?

(Read list if necessary)

I Less than 15 minutes 2 15 to 30 minutes 3 30 to 45 minutes 4 45 to 60 minutes 5 More than 60 minutes 7 (DO NOT READ) Don't know Q7A-F Repeat Q6 sequence for worker #2 Q8A-F Repeat Q6 sequence for worker #3 Q9A-F Repeat Q6 sequence for worker #4 Braidwood Generating Station F-13 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Q 10 And once everyone who is coming home from work has arrived, how long would it take to prepare and depart from home, taking into consideration whether or not someone else is usually home who may be starting these preparation while they are travelling?

1 Less than 15 minutes 2 15 to 30 minutes 3 30 to 45 minutes 4 45 to 60 minutes 5 More than 60 minutes 7 (DO NOT READ) Don't know Q 1I Are any of the licensed drivers in your household restricted to daytime driving only?

1 Yes 2 No 9 (DO NOT READ) Refused Q12 If an evacuation were ordered when all household members were at home (for example, at night or on a weekend), approximately how long would it take your household to prepare to depart? Please assume that you are advised to plan to be away from your home for 3 days. Would you say that it would take... READ LIST 1 Less than 20 minutes to depart 2 20 to 40 minutes to depart 3 40 to 60 minutes to depart 4 60 to 90 minutes to depart; or 5 More than 90 minutes to depart Q 13 How many vehicles would your household take if an evacuation were ordered when all household members were at home?

Record:

  1. of vehicles 998 (DO NOT READ) Refused Q 14 Are any members of your household seasonal residents? And by seasonal we mean any people who do not reside in your home the majority of the year.

I Yes 2 No - SKIP TO Q15 9 (DO NOT READ) Refused Q14A (ASK IF Q14=1) How many of your <insert Q1 response> household members are seasonal?

Record:

  1. of seasonal household members 998 (DO NOT READ) Refused Braidwood Generating Station F-14 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Q14B (ASK IF Q14=1) What seasons do they live in another location away from your home?

READ LIST - Multiple Mention I Spring 2 Summer 3 Fall 4 Winter Q15 Would any member of your household require a specialized vehicle, such as a wheelchair, van or ambulance, to evacuate from your home in case of an emergency?

I Yes 2 No 9 (DO NOT READ) Refused This is all the questions we have for you today/tonight. Thank you for participating in this survey. Your responses will help us to make an accurate prediction of traffic conditions during an emergency situation. If you have any questions about this survey, please feel free to contact

<insert contact name, job title, and phone number/email>.

Braidwood Generating Station Evacuation Time Estimate F-15 KLD Engineering, P.C.

Rev. 0

APPENDIX G Traffic Management Plan

G. TRAFFIC MANAGEMENT PLAN NUREG/CR-7002 indicates that the existing TCPs and ACPs identified by the offsite agencies should be used in the evacuation simulation modeling. The traffic and access control plans for the EPZ were provided by the Illinois Emergency Management Agency.

These plans were reviewed and the TCPs and ACPs were modeled accordingly.

G.1 Traffic Control Points As discussed in Section 9, traffic control points at intersections (which are controlled) are modeled as actuated signals. If an intersection has a pre-timed signal, stop, or yield control, and the intersection is identified as a traffic control point, the control type was changed to an actuated signal in the DYNEV II system. Table K-2 provides the control type and node number for those nodes which are controlled. If the existing control was changed due to the point being a TCP, the control type is indicated as "TCP - Actuated" or "TCP - Uncontrolled" in Table K-2.

The TCPs and ACPs within the study area are mapped in Figure G-1.

G.2 Access Control Points It is assumed that ACPs will be established within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the advisory to evacuate to discourage through travelers from using major through routes which traverse the EPZ.

As discussed in Section 3.6, external traffic was considered on the major routes which traverse the study area 55, 1-80 and 1-355 - in this study. The generation of the external trips ceases at 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after the advisory to evacuate in the simulation due to the ACPs.

As shown in Figure G-1, the TCPs and ACPs identified in the state RERP are concentrated along major evacuation routes and on roadways giving access to the EPZ. These TCPs and ACPs would be manned during evacuation by traffic guides who would direct evacuees in the proper direction away from the plant and facilitate the flow of traffic through the intersections.

Detailed descriptions of each of the TCPs and ACPs and the actions to be taken by traffic guides at these intersections are provided in the state RERP. These actions were modeled explicitly in the DYNEV II system. For additional information, refer to the state RERP.

As discussed in Section 9, this study did not identify any additional intersections as TCPs or ACPs. The existing state traffic management plan is comprehensive and does not require revision.

Braidwood Generating Station G-1 KLD Engineering, P.C.

Evacuation Time Estimate Rev. 0

Figure G-1. Traffic and Access Control Points for the Braidwood Generating Station Braidwood Generating Station Evacuation Time Estimate G-2 KLD Engineering, P.C.

Rev. 0