OT-3701-ADM NRC10-A4 Rev 0 JOB PERFORMANCE MEASURE SETUP SHEET System: Administrative Time Critical: No Applicability: RO/SRO Safety Function: Radiation Control Setting: Classroom Validated: 15 minutes
References:
OBP-OP-4009 rev 0 (p.12), GE C-RWT200901_PY, Attached: Survey Maps A57042, A57403B; RWPs 100002,100005.
Tasks: 299-502-03-01 Maintain Radiation Exposure as Low as Reasonably Achievable (ALARA) 299-848-01-01 Comply with the Administrative Requirements for the Perry Plant Radiation Dose Control Program Task Standard: Calculate maximum stay-time using conect RWP and Survey Map for RHR A walk-down.
K/ A Data: 2.3.7 Ability to comply with radiation work pem1it requirements during n01111al or abnonnal conditions. 3.5/3.6 Required Materials: Calculator
(
- 1. Setup Instructions: N/A
- 2. Location / Method: Classroom / Perfonn
- 3. Initial Condition: The plant is at 100% power. HP reports water leakage in the "A" RHR pump room.
- 4. Initiating Cue: You are to walk-down and inspect the "A" RHR pump and piping. In preparation for this you are to:
- Detennine which, of the two provided survey maps, is the conect survey map to use
- Assuming you remain on the East Side of the pump casing, calculate the maximum stay time before the MG-DRD alanns on Dose Limit.
- State your required actions if the MG-DRD alanns on Dose Limit.
Start Time: _ End Time:
(, Candidate:
OT-3701-ADM NRC10-A4 Rev 0 JPM BODY SHEET
(
Standard: Perfo1111er obtains or simulates obtaining all materials, procedures, tools, keys, radios, etc ...
before perfonning task.
Standard: Perfonner follows management expectations with regards to safety and communication standards.
Step 1 Determine the appropriate survey map.
Critical Step: Operator detem1ines that survey map #57403B is the COlTect map.
Instructor Cue: None Notes: None SAT UNSAT Comment(s): _
(
Step 2 Dete1111ine the appropriate RWP.
Critical Step: Operator detennines that RWP 100002 is the COlTeet RWP.
Instructor Cue: None Notes: RWP 100005 is not for High Rad areas. The survey map shows the RHR room is posted High Rad.
SAT UNSAT Comment(s): _
OT-3701-ADM NRC10-A4 Rev 0 Step 3
(
Calculate the maximum stay time before the MG-DRD alarms on Dose Limit.
Critical Step: Operator divides 25 (the dose limit alarm) by 32 (the east side pump dose) and multiples by 60 (minutes/hour) to obtain 46.875 minutes.
Instructor Cue: None Notes: 46 to 47 minutes is acceptable.
SAT UNSAT Comment(s): _
Step 4 Required actions if the MG-DRD alanns on Dose Limit Critical Step: Operator determines that immediate exit and HP notification is required.
( Instructor Cue: None Notes: None SAT UNSAT Comment(s): _
Terminating Cue: Operator has selected an RWP, Survey Map, performed a dose calculation and stated actions on an alarm.
Evaluation Results: SAT UNSAT End Time:
- . 1 RADIOLOGICAL SURVEY FORf {SURVEY Nl},.1l8ER-----r, ,.AI-' # - 1 RV,/P' UMBI.i~- --;
_ 1001126
___ * ._, 7 02 _ 1-. 10-0621
- .*._ _ _oj I'?* !P..::1B11-o.1.B.eY . .. ._ . . _._ ~_ .:..._ _ _. ._.__. _
I Bun Dl.G __ J r.LEV5'l~ _ I _~RE ~QO~ST~~ ._ __ D:r _03/~1/20~ __
rPfj"- ' - - - ' - - - - - - - - - - _ . - - ' - - ' - - _ . -'-
f PURPOSE
. ._ - Quarterty Taskca'
. . . --- .__.~.__ H*__ __ __ . . . _ ..;..=."'--_
__ --***----:---r----
A 574' - 02
(
I~
I I
P/,GE *.__...*.. OF .... ~. __ ..::...._.