1 NRR-PMDAPEm Resource From:

Feintuch, Karl Sent:

Thursday, May 19, 2011 8:39 AM To:

'thomas.l.breene@dom.com'; 'jack.gazala@dom.com' Cc:

Bedi, Gurjendra; McMurtray, Anthony

Subject:

ME4722 - Sampling Schemes Discussion Reviewer Bedi has responded to the Kewaunee understanding of the selection process for Large Bore Snubbers for testing:

========== begin NRC understanding==================

NRC staff has the following understanding of the same text of OMa-1988, Section 3.2.3.1.a as you quoted:

For the first sample lot tested, 10% of the snubbers in the general population shall be selected. As far as practical, this sample selected for testing shall include the various designs, configurations, operating environments, range or sizes, and capacity of snubbers, etc. The first sample lots tested shall be a composite based on the ratio of each particular category to the total numbers of snubbers installed in the plant. Sample lot selection from the representative categories of snubbers shall be random.

As acknowledged, KPS has a total of 99 snubbers installed onsite that are subject to this Code requirement (2 of these 99 are the SG large bore hydraulic snubbers). Further, these 99 snubbers were randomly assigned into 9 groups per the Code requirement.

However, NRC staff believes that the KPS selection of snubbers to populate the 9 groups from the total of 99 snubbers, must be based on the various attributes of design, configuration, environment, ranges or sizes, and capacity.

Without knowing the details (size, design, location, capacity etc.) of all of the 99 snubbers at KPS, NRC staff believes that there are only two large bore hydraulic snubbers which are SG large bore hydraulic snubbers (LBHSs), each with a capacity of 900 KIPs. If there are no other large bore snubbers, these two snubbers will form a single group (out of 9 groups).

During the 10% sampling process, one SG large bore snubber needs to be selected from this group.

Therefore, for every 10% sampling process, there will be one SG snubbers selected for sample testing.

Applying the NRCs understanding of OMa-1988 leads to a different result than the understanding that KPS applies.

Additional information pertaining to snubber testing:

(1) Please note that the statistical method only provides a confidence that applies to the population as a whole in the absence of testing each snubber. By using this sampling method, the NRC staff has observed for some plants that some of the snubbers were tested few times in their expected life of 40 years while some snubbers were never tested at all. Therefore, based on snubber aging study process, in the NUREG/CR-5870, Results of LWR Snubber Aging Reseach, dated May 1992, the NRC recommended the Service Life Monitoring (SLM) of snubbers in addition to the statistical testing process. Most of the plants have included SLM in their TS, TRM etc. in the past. The ASME OM Code, Subsection ISTD also included SLM along with snubbers examination and inservice testing requirements.

(2) NRC Generic Issue 113, Dynamic Qualification and Testing of Large-Bore Hydraulic Snubbers (LBHSs), recommended that plants should (1) establish a separate ISI/IST LBHS category; and (2)

2 perform fluid sampling and analysis of LBHSs. Some of the plants are following these recommendations. Also these requirements have been incorporated in ASME OM Code.

(3) NRC issued Regulatory Issue Summary (RIS) 2010-06, Inservice Inspection and Testing Requirements of Dynamic Restraints (Snubbers) on June 1, 2010 to remind all the licensees of the NRCs rules and regulations regarding snubber ISI and testing.

(4) Within the regulations 10 CFR 50.55a(g)(5)(ii) states, in part, that If a revised inservice inspection program for a facility conflicts with the technical specification (TS) for the facility, the licensee shall apply to the Commission for amendment of the TSs to conform the TS to the revised program.

====== end NRC staff understanding=============

TheKewauneeUnderstandingofSection3.2.3.1.afollows From: Jack Gadzala [1]

Sent: Thursday, May 12, 2011 4:20 PM To: Feintuch, Karl

Subject:

KPS Relief Request RR-2-2 (ME4722) RAI Discussion

Karl, As a followup from our earlier call today, I am providing the following reference for further discussion.

OMa1998,Section3.2.3.1.astatesthefollowing.

Forthefirstsamplelottested,10%ofthesnubbersinthegeneralpopulationshallbeselected.Asfaras practical,thissampleselectedfortestingshallincludethevariousdesigns,configurations,operating environments,rangeorsizes,andcapacityofsnubbers,etc.Thefirstsamplelotstestedshallbeacomposite basedontheratioofeachparticularcategorytothetotalnumbersofsnubbersinstalledintheplant.Sample lotselectionfromtherepresentativecategoriesofsnubbersshallberandom.

KPShasatotalof99snubbersinstalledonsitethataresubjecttothisCode(2ofthese99arethelargeboresnubbers).

These99snubberswererandomlyassignedinto9groupspertheCoderequirement(all99ofthesesnubbersarepart ofthegeneralpopulation).Thisrandomselection,incompliancewiththeaboveCoderequirement,resultedinthe2 largeboresnubbersbeingassignedintotwodifferentgroups(sincetheCoderequiresthatthesamplegroupseach includethevarioustypesofsnubbers).Assuch,thecurrentCodeofRecordonlyrequiresthatthesesnubbersbetested atthesameintervalasanyothersnubberonsite.Consequently,theCodeofRecorddoesnotrequirethatthelarge boresnubbersbetestingmorefrequentlythananyothersnubbersubjecttotheCode(forthecurrent10year interval).

Weunderstandthatforthenext10yearinterval,thiswillneedtochange(i.e.,thesnubberswillbegroupedseparately perthenewereditionoftheCode).However,theexistingCodeofrecorddoesnotrequirethis.

Jack Dominion KPS Licensing 920-388-8604

CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The

3 information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.

Hearing Identifier:

NRR_PMDA Email Number:

42 Mail Envelope Properties (26E42474DB238C408C94990815A02F094C0C5287F3)

Subject:

ME4722 - Sampling Schemes Discussion Sent Date:

5/19/2011 8:39:12 AM Received Date:

5/19/2011 8:39:00 AM From:

Feintuch, Karl Created By:

Karl.Feintuch@nrc.gov Recipients:

"Bedi, Gurjendra" <Gurjendra.Bedi@nrc.gov>

Tracking Status: None "McMurtray, Anthony" <Anthony.McMurtray@nrc.gov>

Tracking Status: None

"'thomas.l.breene@dom.com'" <thomas.l.breene@dom.com>

Tracking Status: None

"'jack.gazala@dom.com'" <jack.gazala@dom.com>

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 6758 5/19/2011 8:39:00 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: