ML101160149

From kanterella
Jump to navigation Jump to search

Enclosure 3: Meeting Slides, Prairie Island ISFSI TN-40HT Amendment Second Request for Additional Information
ML101160149
Person / Time
Site: Prairie Island  
Issue date: 04/22/2010
From: Pamela Longmire
NRC/NMSS/SFST/LID/LB
To: Douglas Weaver
NRC/NMSS/SFST/LID
Shared Package
ML101160130 List:
References
TAC L24203
Download: ML101160149 (17)


Text

1 Prairie Island ISFSI TN-40HT Amendment Second Request for Additional Information (RAI)

Public Meeting April 20, 2010

2 Agenda Purpose Importance of TN-40HT Amendment Prairie Island (PINGP) Independent Spent Fuel Storage Installation (ISFSI) Background TN-40HT Amendment Status Outstanding Request for Additional Information (RAI) Issues Schedule Questions

3 Purpose Communicate importance of amendment Communicate Xcel responses, solicit feedback for supplement Promote license amendment progress Mutually-agreeable schedule for amendment

4 Importance of TN-40HT Amendment Essential for reactor operation after 2012 40-assembly capacity essential Strategic

- State Certificate of Need assumed TN-40HT

- State of Minnesota legislative stay Cask fabrication is at risk Need for TN-40HT Amendment

- Spent fuel discharge status

5 PINGP ISFSI Background Site-Specific License (1993)

One cask design (TN-40)

Mature ISFSI Program

6 Outstanding RAI Issues Helium Leak Testing of base metal

- 2nd Round RAI A5-2 [ML093310293]

QA Categories not NUREG/CR-6407

- 2nd Round RAI A1-1 [ML093310293]

TN use of foreign material standards

7 TN-40HT Amendment Status Submitted 3-28-2008 RAI response 6-26-2009 RAI response 1-18-2010

- Telecon 1-27-2010

- Telecon 2-1-2010

- Telecon 4-1-2010 Three (3) outstanding items Amendment review suspended

8 Issue: Helium Leak Testing of Base Metal N14.5 fabrication testing refers to entire containment boundary

9 Reply: Helium Leak Testing of Base Metal SAR already requires fabrication helium leak test of welds and seals Revise SAR to extend fabrication leak test to include:

- shell base metal

- lid plate and port covers

- All tests in compliance with N14.5

10 Issue: QA Categories not NUREG/CR-6407 Existing QA Categories not per NUREG

11 Reply: QA Categories not NUREG/CR-6407 Adopt NUREG categories for TN-40HT

- QA Topical Report allows for NUREG categories

- Revise TN-40HT parts list categories

12 Issue: TN use of foreign material standards SAR does not define equivalence for use of non-ASTM materials

13 Reply: TN use of foreign material standards Only ASTM/ASME materials will be used on Important to Safety parts as listed on SAR drawings SAR drawings will be revised to remove note that allowed equivalent material standards

14 Summary

1. Helium leak test entire cask
2. Implement NUREG/CR-6407 categories
3. Remove ASTM equivalence note from SAR Drawings

15 Schedule Targeting responses by May 7th Fall 2010 cask loading campaign Requested 90 days for implementation

16 Questions

17 Xcel Energy*