ML063460507

From kanterella
Jump to navigation Jump to search

E-MAIL: (PD) Information Pilgrim LRA
ML063460507
Person / Time
Site: Pilgrim
(DPR-035)
Issue date: 05/19/2006
From: Egan J
Entergy Corp
To: Duda S, Nash H, Williamson A
- No Known Affiliation, Office of Nuclear Reactor Regulation
References
%dam200612, TAC 3698
Download: ML063460507 (3)


Text

Page 1 of 1 Duda, Steve From:

Egan, Joseph [jeganl @entergy.com]

Sent:

Friday, May 19, 2006 4:45 PM To:

Harriet Nash; Duda, Steve; Alicia Williamson Cc:

Ellis, Douglas; Scheffer, Jacob

Subject:

Information re: Pilgrim LRA Attachments: MEMP Rept-Series list.doc; PNPS lmpg_ Nov-Dec '05.doc I trust you all had a good return trip. Thanks for spending time with us yesterday, I felt it was very worthwhile.

I have enclosed 2 documents (WORD files) that you requested:

1. [item 298] List of reports in the series prepared by Mass. Division of Marine Fisheries (Bob Lawton et al.) relating to Pilgrim.

These all have the heading Marine Environmental Monitoring Program (MEMP). I am planning to send report numbers 6,8,9+10 to you.

The others (1,4,5+7) have already been provided.

2. Info on minor Fish impingement incidents in November/December 2005. Entergy is agreeable if you choose to docket this 'table'.

Also, I came across a reference on "Overfishing, Contamination, and Habitat Degradation" you may find interesting...

[link = http://massbay.mit.edu/publications/NEFishResources/index.htmrl.

Please feel free to contact me with any questions, concerns or recommendations.

Thanks, Joe J.W. Egan 508.830.8915 Environmental Protection Group Entergy Nuclear -

PILGRIM STATION

'jeganl@entergy.com' 10/24/2006

Mass. Division of Marine Fisheries - Marine Environmental Monitoring Program MEMP Report Series I - 10 [nos. 2+3 missing] Prepared by Mass. DMF [R. Lawton et al.]

Sponsored by Pilgrim Station (Entergy / Boston Edison) 1 1

l i

e I I i

l i

l l

i i i--

l i l i l i 1-I l l e l i o i-i

- I l e - i l i MEMP #1 January 1986 FINAL REPORT ON DISSOLVED GAS SATURATION IN THE INSHORE MARINE WATERS OF CAPE COD BAY AND INCIDENTS OF GAS BUBBLE DISEASE AT PILGRIM NUCLEAR POWER STATION, 1973-1985

==----

MEMP Reports 2+3 missing, subjects unknown.

=--------------------------=----

MEMP#4 June 1990 FINAL REPORT ON SPAWNING SEA-RUN RAINBOW SMELT (Osmerus mordax)

IN THE JONES RIVER AND IMPACT ASSESSMENT OF PILGRIM STATION ON THE POPULATION, 1979-1981 MEMP #5 December 1992 FINAL REPORT ON IRISH MOSS (Chondrus crispus) HARVESTING ALONG THE PLYMOUTH SHORELINE AND IMPACT ASSESSMENT OF PILGRIM STATION ON THE FISHERY, 1971 -w1 982 MEMP #6 December 1992 FINAL REPORT ON HAUL-SEINE SURVEY AND IMPACT ASSESSMENT OF PILGRIM STATION ON SHORE-ZONE FISHES, 1981-1991 MEMP #7 November 1995 FINAL REPORT ON BOTTOM TRAWL SURVEY (1970-1982)

AND IMPACT ASSESSMENT OF THE THERMAL DISCHARGE FROM PILGRIM STATION ON GROUNDFISH MEMP #8 December 1999 FINAL REPORT ON RAINBOW SMELT RESTORATION EFFORTS IN THE JONES RIVER, 1994-1999

==--

MEMP#9 January 2000 FINAL REPORT-STUDIES (1990-1997) AND IMPACT ASSESSMENT OF PILGRIM STATION ON CUNNER IN WESTERN CAPE COD BAY MEMP #10 March 2000 FINAL REPORT - WINTER FLOUNDER STUDIES (1993-1999)

IN RELATION TO IMPACT ASSESSMENT OF PILGRIM STATION ON THE LOCAL POPULATION

?

Pilgrim Station Environmental FISH IMPINGEMENT -

Nov, Dec. 2005 5 Minor Incidents [1] Nov. 2-3 [2] Nov. 12 [3] Nov. 30-Dec. 1 [4] Dec. 10 [5] Dec. 14-15 Incident#1 11/2-11/3/05 (1

Estimated Number Impinged = 400, Total Duration = 17 hours1.967593e-4 days <br />0.00472 hours <br />2.810847e-5 weeks <br />6.4685e-6 months <br /> > 20/hr, Total No. Species [when rate elev.] = 4 16.8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />) Wed. pm predom. spec. - menhaden (YOY)

Max. Rate = 28/hr [28, 23, 24, 8]

No. Species > 20 per hour = 1 10 days later Incident #2 11/12/05 Estimated Number Impinged = 301 Total Duration = 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> > 20/hr, Total No. Species [when rate elev.] =

(9.8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />) Fri midn.

3, predom. spec. - menhaden (YOY)

Max. Rate = 29/hr [29,29, 6]

4 No. Species > 20 per hour = 1 18 days later Incident #3 11/30 - 12/1/05 (1

Estimated Number Impinged = 300, Total Duration = 11 hours1.273148e-4 days <br />0.00306 hours <br />1.818783e-5 weeks <br />4.1855e-6 months <br /> > 20/hr, Total No. Species [when rate elev.] = 9 10 days later 10.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />) Wed. pm predom. spec. - blueback herring (YOY)

Max. Rate = 40/hr [40, 10, 20, 12]

No. Species > 20 per hour = 1 i.2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />) Fri midn.

predom. spec. - cunner, str. killifish Max. Rate = 21.3/hr [21, 5]

No. Species > 20 per hour = 0 Incident #4 12/10/05 (r

Estimated Number Impinged = 110, Total Duration = 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> > 20/hr, Total No. Species [when rate elev.] = 8 4 days later Incident #5 12/14 - 12/15/05 (15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />) Wed. pm Estimated Number Impinged = 500, Total Duration = 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> >'20/hr, Total No. Species [when rate elev.] = 9 predom. spec. - Atl. silverside Max. Rate = 37/hr [37,32,5]

No. Species > 20 per hour = 1