D. shly-Some info on PenPageio1 From:

<john.hufnagel @ exeloncorp.com>

To:

<djal @nrc.gov>

Date:

08/15/2006 4:47:03 PM

Subject:

Some info on Penetrations

Donnie, Attached is a table that has elevation and azimuth information on the larger penetrations. Please pass on to Jason and let's set up a call for sometime later this week if possible. Ahmed is out at TMI for a plant walk down tomorrow, but we can perhaps discuss schedule for obtaining other information with Don W.

Thanks.

- John.

<<Drywell Large Penetrations.doc>>

This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.

This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout.

Thank You.

CC:

<donald.warfel @ exeloncorp.com>, <ahmed.ouaou @ exeloncorp.com>

N, r-,Atemp\\GWJ00001.TMP Paae 1 11 i c:\\temp\\GWIOOOO1.TMP Paae 1 II Mail Envelope Properties (44E232B8.FB4 : 7: 12212)

Subject:

Creation Date From:

Created By:

Some info on Penetrations 08/15/2006 4:46:37 PM

<iohn.hufnagel @exeloncorD.com>

john.hufnagel @exeloncorp.com Recipients nrc.gov DJA1 (D. Ashley) exeloncorp.com ahmed.ouaou CC donald.warfel CC Post Office Route nrc.gov exeloncorp.com Files MESSAGE TEXT.htm Drywell Large Penetrations.doc Mime.822 Options Expiration Date:

Priority:

ReplyRequested:

Return Notification:

Concealed

Subject:

Security:

Size 1260 1883 39936 60702 Date & Time 15 August, 2006 4:46:37 PM None Standard No None No Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled

11 D. Ashley -, Dryvýell Large Penetrations.doc Pageýjij kP~. Ashley - Drywell Large Penetrations.doc Page 1 DRYWELL PENETRATIONS 4 INCH DIAMETER AND LARGER Penetratio Pipe System Name1 Elevation Azimuth Load n

Diameter Ft-In2 Deg -

Number1 Inch min2 X-1A, B 120 DW Personnel/Equip. Hatch 27 - 6 342 - 0 X-2A 24 Main Steam 27 - 0 171 - 15 X-2B 24 Main Steam 27 - 0 188 - 45 X-3A 10 Isolation Condenser(steam supply) 90 - 0 10-30 X-3B 10 Isolation Condenser(steam supply) 90 - 0 349 - 30 X-4A 18 Feedwater 33 - 0 167 - 30 X-4B 18 Feedwater 33 - 0 192 - 30 X-5A 10 Isolation Condenser(Cond. return) 87 - 5 19 - 30 X-5B 10 Isolation Condenser(Cond return) 87 - 5 340 - 30 X-7 14 Shutdown Cooling (Supply) 42 - 0 325 - 0 X-8 14 Shutdown Cooling (Return) 58-3 290-15 X-9 6

Reactor cleanup (return) 62 - 0 85 X-10 6

Reactor Cleanup (Supply) 62 - 0 95 X-12B 8

Core Spray (Supply) 62 - 0 250 - 0 X-70 8

Core Spray (Supply) 79 - 6 100 - 0 X-18 18 Ventilation Intake 84 - 0 190 -0 X-19 18 Ventilation Exhaust 21 -3 314 - 30 X-20A 6

DW closed Cooling (Supply) 47 - 6 5 - 0 X-20B 6

DW closed cooling (Return) 47 - 6 10 - 0 X-63 14 Containment Spray (Supply) 62 330 - 0 X-66 14 Containment Spray 27 38 - 0 Based on UFSAR Table 6.2-12 2 Based on CB&I fabrication drawings 9-0971-Series