Marc leerdas -F-w: Oyster Creek shennigans Page 1i From:
Ronald Bellamy To:
Marc Ferdas Date:
9/27/2006 3:38:02 PM
Subject:
Fwd: Oyster Creek shennigans
>>> Donald Jackson 09/27/2006 3:32 PM >>>
FYI
>>> 'Dave Lochbaum" <dlochbaum @ ucsusa.orq> 09/26/2006 2:26 PM >>>
Hello Mr. Jackson:
Attached please find a letter regarding the recent NRC inspection report on Oyster Creek. The "observation" in the torus room troubled us on two counts:
- 1) NRC has repeatedly wamed licensees not to precondition before tests and inspections, yet AmerGen preconditioned the torus room before the NRC team got there.
- 2) AmerGen's explanation about water being in the collection jogs for the first time ever is truth-challenged.
- Thanks, Dave Lochbaum Director, Nuclear Safety Project Union of Concerned Scientists 1707 H Street NW Suite 600 Washington, DC 20006-3962 (202) 223-6133 (office)
(202) 331-5430 (direct line)
(202) 223-6162 (fax)
c.\\t6ep\\GW)060')l.TMP teGW1OO0~1.TMP Pane 1 I Page 1 i Mail Envelope Properties (451AD31A.AD9: 0 :26993)
Subject:
Creation Date From:
Created By:
Fwd: Oyster Creek shennigans 9/27/2006 3:38:02 PM Ronald Bellamy RRB1@nrc.gov Recipients nrc.gov kpl-po.KP_.DO MSF2 (Marc Ferdas)
Post Office kpl-po.KPDO Route nrc.gov Files Size MESSAGE 1871 20060926-oc-ucs-nrc-preconditioning.pdf PM Date & Time 9/27/2006 3:38:02 P 211616 9/27/2006 3:32:24 Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
None Standard No None No Standard Junk Mail Handling Evaluation Results Message is not eligible for Junk Mail handling Message is from an internal sender Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled