_TimothyO'Hara - Oyster Creek, Drywell and Torus related Inspection Schedule

-'I From:

To:

Date:

Subjec

<Peter.Tam burro @ exeloncorp.com>

<TLO1 @nrc.gov>

09/26/2006 12:37:53 PM t:

Oyster Creek, Drywell and Torus related Inspection Schedule Tim Attached is a summary of the Outage Schedule for Drywell and Torus related Inspections (as of If there are any question please call - (609)-971-4141

<<Schedule Trans to NRC.doc>>

9/25/06 This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.

This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout.

Thank You.

CC:

<pdk@nrc.gov>, <howie.ray@ exeloncorp.com>, <johnf.orourke@exeloncorp.com>,

<Tom.Quintenz @ exeloncorp.com>

1 :\\te

\\GW100001.TMP P-a-a -e 1ý I OW}oooO1.TMP Paoe ill Mail Envelope Properties (4519573C.67F: 10 : 18047)

Subject:

Creation Date From:

Created By:

Oyster Creek, Drywell and Torus related Inspection Schedule 09/26/2006 12:36:59 PM

<Peter.Tamburro @exeloncorm.com>

Peter.Tamburro @exeloncoro.com Recipients nrc.gov kplpo.KPDO TLO1 (Timothy O'Hara)

PDK CC (Paul Kaufman) exeloncorp.com Tom.Quintenz CC johnf.orourke CC howie.ray CC Post Office kpl-po.KPDO Files MESSAGE TEXT.htm Schedule Trans to NRC.doc Mime.822 Options Expiration Date:

Priority:

ReplyRequested:

Return Notification:

Concealed

Subject:

Security:

Route nrc.gov exeloncorp.com Size 1135 1982 26112 41884 Date & Time 09/26/2006 12:36:59 PM None Standard No None No Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User

c:\\temp\\GW})0001.TMP

"-bi Page 21I Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled

Activity Spec/Section Early Start Early Activity Ref.

Date &

Finish Date No.

Time.

& Time Internal UT Inspections of IS-328227-Oct.; 16; Oct 17; R209125801 the Upper Drywell 004 Sec 12:00 12:00 3.2.1 Visual Inspection of Sec. XI; Oct. ;16; Oct 17; 9:00 R209080401 Internal Drywell Shell IWE 9:00 Surface (IWE)

Visual Inspection of IS-328227-Oct. ;18; Oct 19; R208890301, Exterior Sandbed Coating 004 Sec 17:00 18:00 0501, 0601, in Bays 1, 5, 7, 9, 13, 15 3.2.4 0801, 2001, and 19 2401, 2601, UT Inspection of thin IS-328227-Oct. ;19; Oct. ;20; R20889206 areas found in 1992 on 004 Sec 17:00 15:00 C201347701 Exterior Sandbed in Bays 3.2.3 1, and 13 Leakage monitoring of Oct. ;17; J208849501 Sandbed Drains and Rx 23:00 Cavity Trough Drains Visual and UT Inspection IS-328227-Oct. ;18; Oct 20; C201347802 of Bay 5 Trench 004 Sec 6:00 16:00 3.2.6 Visual and UT Inspection IS-328227-Oct. ;18; Oct 20; C201347803 of Bay 17 Trench 004 Sec 6:00 16:00 3.2.6 Torus Diver Inspections SP-1302 Oct. 21; 0600 Oct. 28; R208598309 120 Sec 4.0 0800 Internal UT Inspection of IS-328227-Oct. 21; 0300 Oct. 22; R209091701 Drywell in the Sandbed.

004 Sec 0300 1 3.2.2 1

1 1

I

_ I _

_ I _

I

_