December 13, 2005 Mr. Joseph E. Venable Vice President Operations Entergy Operations, Inc.
17265 River Road Killona, LA 70066-0751
SUBJECT:
WATERFORD STEAM ELECTRIC STATION UNIT 3 RE: TEMPORARY EXEMPTION FROM THE REQUIREMENTS OF 10 CFR PART 50, APPENDIX E, SECTION IV.F.2.b AND c (TAC NO. MC8756)
Dear Mr. Venable:
The U.S. Nuclear Regulatory Commission (NRC) has approved the enclosed exemption from specific requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix E,Section IV.F.2.c and b for the Waterford Steam Electric Station, Unit 3. This action is in response to your letter dated October 24, 2005, that requested an exemption from the requirement of Appendix E,Section IV.F.2.c that requires offsite plans for each site to be exercised biennially with full participation by each offsite authority having a role under the plan.
Though not referenced in your request, the NRC staff has determined that an exemption from Section IV.F.2.b of Appendix E to 10 CFR Part 50 is also necessary.
The letter requested that the exercise be rescheduled to June 28, 2006. The NRC staff understands that future exercises would be scheduled biennially from the year 2005.
A copy of the exemption has been forwarded to the Office of the Federal Register for publication.
Sincerely,
/RA/
Mel B. Fields, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-382
Enclosure:
Exemption cc w/encl: See next page
Waterford Steam Electric Station, Unit 3 cc:
Mr. Michael E. Henry, State Liaison Officer Regional Administrator, Region IV Department of Environmental Quality U.S. Nuclear Regulatory Commission Permits Division 611 Ryan Plaza Drive, Suite 400 P.O. Box 4313 Arlington, TX 76011 Baton Rouge, Louisiana 70821-4313 Parish President Council Vice President Operations Support St. Charles Parish Entergy Operations, Inc. P. O. Box 302 P. O. Box 31995 Hahnville, LA 70057 Jackson, MS 39286-1995 Executive Vice President Director & Chief Operating Officer Nuclear Safety Assurance Entergy Operations, Inc.
Entergy Operations, Inc. P. O. Box 31995 17265 River Road Jackson, MS 39286-1995 Killona, LA 70066-0751 Chairman Wise, Carter, Child & Caraway Louisiana Public Services Commission P. O. Box 651 P. O. Box 91154 Jackson, MS 39205 Baton Rouge, LA 70825-1697 General Manager Plant Operations Vanessa E, Quinn, Chief Waterford 3 SES Radiological Emergency Preparedness Entergy Operations, Inc. Section 17265 River Road Department of Homeland Security Killona, LA 70066-0751 1800 S. Bell Street, Room 837 Crystal City - Arlington, VA 22202-3546 Licensing Manager Entergy Operations, Inc.
17265 River Road Killona, LA 70066-0751 Winston & Strawn 1700 K Street, N.W.
Washington, DC 20006-3817 Resident Inspector/Waterford NPS P. O. Box 822 Killona, LA 70066-0751 December 13, 2005 May 2005
Mr. Joseph E. Venable Vice President Operations Entergy Operations, Inc.
17265 River Road Killona, LA 70066-0751
SUBJECT:
WATERFORD STEAM ELECTRIC STATION UNIT 3 RE: TEMPORARY EXEMPTION FROM THE REQUIREMENTS OF 10 CFR PART 50, APPENDIX E, SECTION IV.F.2.b AND c (TAC NO. MC8756)
Dear Mr. Venable:
The U.S. Nuclear Regulatory Commission (NRC) has approved the enclosed exemption from specific requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix E,Section IV.F.2.c and b for the Waterford Steam Electric Station, Unit 3. This action is in response to your letter dated October 24, 2005, that requested an exemption from the requirement of Appendix E,Section IV.F.2.c that requires offsite plans for each site to be exercised biennially with full participation by each offsite authority having a role under the plan. Though not referenced in your request, the NRC staff has determined that an exemption from Section IV.F.2.b of Appendix E to 10 CFR Part 50 is also necessary.
The letter requested that the exercise be rescheduled to June 28, 2006. The NRC staff understands that future exercises would be scheduled biennially from the year 2005.
A copy of the exemption has been forwarded to the Office of the Federal Register for publication.
Sincerely,
/RA/
Mel B. Fields, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-382
Enclosure:
Exemption cc w/encl: See next page Distribution:
PUBLIC LPLIV Reading RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDorlLplg (DTerao) RidsNrrPMMFields RidsNrrLADJohnson RidsRgn4MailCenter (DGraves) NMamish DBarss NrrDorl (KWilliams) JDixon-Herrity, EDO RIV A Gody, Region IV ADAMS Accession Number: ML053470524 NRR-048 OFFICE NRR/LPL4/PM NRR/LPL4/PM NRR/LPL4/LA NSIR/EP OGC NRR/LPL4/BC NRR/DORL NAME NKalyanam MFields DJohnson EWeiss MSpencer nlo DTerao CHaney DATE 12/12/05 12/12/05 12/12/05 12/01/2005 12/01/2005 12/12/05 12/13/05 E:\Filenet\ML053470524.wpd OFFICIAL RECORD COPY
7590-01-P UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ENTERGY OPERATIONS, INC.
WATERFORD STEAM ELECTRIC STATION, UNIT 3 DOCKET NO. 50-382 EXEMPTION
1.0 BACKGROUND
Entergy Operations, Inc. (the licensee) is the holder of Facility Operating License No. NPF-38 which authorizes operation of Waterford Steam Electric Station, Unit 3 (Waterford 3).
The license provides, among other things, that the facility is subject to all rules, regulations, and orders of the U.S. Nuclear Regulatory Commission (NRC, the Commission) now or hereafter in effect.
The facility consists of one pressurized-water reactor located in St. Charles Parish, Louisiana.
2.0 REQUEST/ACTION Sections IV.F.2.b and c of Appendix E, to Title 10 of the Code of Federal Regulations (10 CFR) Part 50 require the licensee at each site to conduct an exercise of its onsite emergency plan and of its offsite emergency plans biennially with full or partial participation by each offsite authority having a role under the offsite plan. During such biennial exercises, the NRC evaluates onsite and the Federal Emergency Management Agency (FEMA) evaluates offsite emergency preparedness activities, including interaction with the various State and local emergency
management agencies. The licensee successfully conducted a full-participation emergency preparedness exercise on May 21, 2003, and it was evaluated by the NRC and FEMA.
The licensee had scheduled a plume exposure pathway exercise for December 7, 2005.
However, due to Hurricanes Katrina and Rita, the State of Louisiana was unable to support the exercise. Under the current regulations, the licensee would have had until December 31, 2005, to complete its next biennial full or partial-participation emergency preparedness exercises consisting of both onsite and offsite exercises. By letter dated October 24, 2005, the licensee requested an exemption from Section IV.F.2.c of Appendix E to 10 CFR Part 50. Though not referenced in the licensees request, the NRC staff has determined that an exemption from Section IV.F.2.b of Appendix E to 10 CFR Part 50 is also necessary, since the last full participation onsite exercise was completed on May 21, 2003. The licensee commits to conduct the next biennial full participation emergency preparedness exercise on June 28, 2006. Future onsite and offsite exercises will be scheduled biennially from the year 2005.
3.0 DISCUSSION The Commission, pursuant to 10 CFR 50.12(a)(1), may grant exemptions from the requirements of 10 CFR Part 50 that are authorized by law, will not present an undue risk to public health and safety, and are consistent with the common defense and security. The Commission, however, pursuant to 10 CFR 50.12(a)(2), will not consider granting an exemption unless special circumstances are present. Under 10 CFR 50.12(a)(2)(ii), special circumstances are present when application of the regulation in the particular circumstances would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule. Under 10 CFR 50.12(a)(2)(v), special circumstances are present whenever the exemption would provide only temporary relief from the applicable regulation and the licensee or applicant has made good faith efforts to comply with the regulation.
The underlying purposes for conducting a biennial exercise are to ensure that emergency organization personnel are familiar with their duties and to test the adequacy of emergency plans.
In order to accommodate the scheduling of exercises, the NRC has allowed licensees to schedule the exercises at any time during the calendar biennium. Conducting the Waterford 3 exercise in calendar year 2006 places the exercise past the previously scheduled biennial calender year of 2005.
Since the last exercise conducted at Waterford 3 on May 21, 2003, Waterford 3 has conducted two emergency response team tabletops (site drills without state or parish participation) on August 8 and December 9, 2003, and Waterford 3 site-wide drills (which includes state and parish participation) on March 11, June 17, September 30, and December 2, 2004, and February 17, and August 4, 2005. The licensee also states:
Emergency response team tabletops are conducted prior to each site-wide drill. The local parishes had limited participation (communication only) in each of the site-wide drills. The Louisiana Office of Homeland Security and Emergency Preparedness also participated to a limited extent (communications only) in these drills. The Louisiana Department of Environmental Quality participated in all the site-wide drills by manning the Waterford 3 Emergency Operations Facility and the Emergency News Center.
The NRC and FEMA did not participate in any of the tabletops or site-wide drills.
Although these drills were not evaluated by NRC and FEMA, the results were critiqued by the drill participants, our emergency response organization, and the parish and state officials who participated in the drills. The drills were also evaluated by our Quality Assurance Department. An emergency preparedness medical drill at Ochsner Medical Center (Ochsner) took place on July 23, 2003, and FEMA evaluated a medical drill at Ochsner on August 6, 2003. Issues identified during all emergency
preparedness drills and in the critiques that follow all the drills have been resolved or are being resolved under our corrective action program.
The Waterford 3 emergency response, along with the parish and state emergency response, were further tested as a result of Hurricane Katrina. Many of the elements of the Waterford 3 emergency response were implemented in the preparation, response, and restoration efforts for Hurricane Katrina. This includes activation of the Waterford 3, parish and state emergency response organizations, evacuation and re-entry of the population, environmental sampling, and assisting Waterford 3 in the plans for restart of the unit.
The NRC staff considers the intent of the regulatory requirement is met by having conducted these series of drills and the emergency response to Hurricane Katrina. The NRC staff considers that these measures are adequate to maintain an acceptable level of emergency preparedness during this period, satisfying the underlying purposes of the rule. Therefore, the special circumstances of 10 CFR 50.12(a)(2)(ii) are satisfied. In addition, the staff has concluded that the above drills and exercises provide adequate protection of the public health and safety and are consistent with the common defense and security.
Only temporary relief from the regulation is provided by the requested exemption, since Waterford 3 will resume their normal biennial exercise schedule in 2007. The licensee has made a good faith effort to comply with the regulation. The exemption is being sought by the licensee in response to a request by the State of Louisiana to postpone the exercise. Louisiana was unable to support the original schedule for the exercise due to a series of severe weather events. FEMA, in its letter dated October 14, 2005, to the State of Louisiana, stated, ...we concur that the Waterford-3 Radiological Emergency Preparedness (REP) Exercise currently scheduled for December 7, 2005,
... should be postponed due to the effects of Hurricanes Katrina and Rita on the local infrastructure....
The NRC staff, having considered the schedule and resource issues with those agencies that participate in and evaluate the offsite portion of the exercises, concludes that the licensee made a good faith effort to meet the requirements of the regulation. The NRC staff, therefore, concludes that the exemption request meets the special circumstances of 10 CFR 50.12(a)(2)(v) and should be granted.
4.0 CONCLUSION
Accordingly, the Commission has determined that, pursuant to 10 CFR 50.12(a), the exemption is authorized by law, will not present an undue risk to the public health and safety, and is consistent with the common defense and security. Additionally, special circumstances are present, which make conducting the exercise impracticable in 2005, and which allow the underlying purposes of the regulation to be served with a postponement. Therefore, the Commission hereby grants Entergy Operations, Inc. an exemption from the requirements of 10 CFR Part 50, Appendix E, Sections IV.F.2.b and c for Waterford 3.
Pursuant to 10 CFR 51.32, the Commission has determined that the granting of this exemption will not have a significant effect on the quality of the human environment (70 FR 73311).
This exemption is effective upon issuance.
Dated at Rockville, Maryland, this 13th day of December, 2005.
FOR THE NUCLEAR REGULATORY COMMISSION
/RA/
Catherine Haney, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation