Plant Status Report
ML051920055
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 04/13/2004
From:
Nuclear Management Co
To:
Office of Nuclear Reactor Regulation
References
FOIA/PA-2004-0282
Download: ML051920055 (2)


Text

Committed to Nuclear Ezcelec' Plant Status Report Plant: Point Beach Nuclear Plant Date: Tuesday, April 13, 2004 Operations Report (Summary of Last 24 Hours of Operations):

Unit I is at refueling shutdown (Mode 6). Reactor coolant system is at 70%. Unit 2 is at I100% power.

Days Without LTA: 570 Homeland Security Condition: Yellow PWR rWR - ~ VW rW wR PVVR MWE AIIT, Mode Level Gj( Le)Md Lee(Gos(Nt 6 0% 0\ I,/ 0 I 100% 543.3 521.2 Days On Line: 0 Days SinceLast Raetaor Trip: 271 Days On Line: 145 Days Since Last Reactor Trip: 277 Item Unit Condition out or Service Length Tech Expires Responsibility Equip (Ilr/Days) Spec Expected Number _______ ___ RTS Date Date Time Date Time 2RC-508, 2 Out of 11/9/03 0749 31 Days 3.6.3.A 4/26/04 1900 M. Rosseau 8127104 U2CRMW service.

Supply_

1. ~ Ivia IOr Ar-auipment Liiut of ervice nrli~egraned .0i' Item Unit Condition Date Time Work Order Number Due Date Responsibility K-213, Instrument 0 Failed SW solenoid. 4/8/04 1708 WO 0407694 4/12/0-4 D. Laing Air Compressor ____

G-500, G-05 GT 0 Out of service. Fuel 4/11/04 2250 WO 0407739 4/12/04 N. Stuart Generator oil leak.

Starting Diesel Engine _______ ___ _____

  • k:  ;~ 'O.F~i ih Probkefiiis 7_____________

Item Unit Condition Actions Needed Due Date Responsibility W-30B3, F-23/F-29 0 Motor failed. Motor on-site for re-installation. 4/10/04 D. Laing PAB Exhaust Filter Fan___________ _

2RC-508, U2C 2 Valve comes off shut seat Provide decision tree to Plant 4/16/04 K. Krause Reactor Makeup momentarily when RMW pump Manager.

Supply starts.______ ______

Unit 2, Excess 2 Inadequate excess letdown flow. Open and inspect, 2CV-285. 5n104 N. Stuart Letdown Flow ________________ _____________

2RE-2IS, 2HX-46 Air 2 Elevated indication, temperature 4 step action plan is developed. 5/14/04 .B. Carberry Ejector Gas Monitor ____related. Scheduled completion is 5/14/04. _____ _______

I _ _ _ _ I. _ I __ _ _ _ _ I _ _ _ _ _ _ I _ _ _ I __ I

[N Item iUnit Condition .Actions Planned Due Date Responsibility

-:' --" . , . " - il- 1'_-z e, 1 , . 'i-"'

!I--- " '

I NONE I Information Inthis reitord wat deleted inaccordance with t efreedom of Information t

Pagel1 of 2 5-5 *1-AA yptlo /s_