Text
ExeI ¢n SM Exelon Generation Company, LLC www.exeloncorp.com NEclear LaSalle County Station uclear 2601 North 21" Road Marseilles, IL 61341-9757 October 15, 2004 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 LaSalle County Station, Units 1 and 2 Facility Operating License Nos. NPF-1 1 and NPF-1 8 NRC Docket Nos. 50-373 and 50-374
Subject:
Amended 90-Day Post Outage ISI Summary Reports
References:
(1) Letter from Charles G. Pardee (Exelon) to the United States Nuclear Regulatory Commission, "90-Day Post Outage ISI Summary Report," dated, February 20, 2001.
(2) Letter from George P. Barnes (Exelon) to the United States Nuclear Regulatory Commission, "Post Outage 90-Day Inservice Inspection (ISI) Summary Report,"
dated, May 6, 2002.
(3) Letter from George P. Barnes (Exelon) to the United States Nuclear Regulatory Commission, "Post Outage 90-Day Inservice Inspection (ISI) Summary Report,"
dated, May 21, 2003.
Exelon Generation Company, LLC (EGC), submitted the above referenced letters associated with the eighth refueling outage for Unit 2 (L2R08), the ninth refueling outage for Unit 1 (L1 R09) and the ninth refueling outage for Unit 2 (L2R09). The documentation for several replacement activities was omitted in error. The required documentation is enclosed. Attached is the amended Table E for each Summary Report and the associated FORM NIS-2, Owner's Report of Repairs or Replacements.
0IO41
October 15, 2004 U.S. Nuclear Regulatory Commission Page 2 If you have any questions concerning this letter, please contact Mr. Terrence W. Simpkin, Regulatory Assurance Manager, at (815) 415-2800.
Respectfully, George P. Barnes Site Vice President LaSalle County Station Attachments
UNIT 2 Amended Table E L2R08 Replacement Activities The following Unit 2 Owner's Report of Repairs or Replacements, form NIS-2, have been prepared by the ISI Program Owner and certified by the Authorized Nuclear Inservice Concrete Inspector (ANIC):
Work Order Number Description
- 1. 99128403 Replace Snubber Load Pin Assembly
- 2. 99129499 Replace Snubber Load Pin Assembly
UNIT 1 Amended Table E LI R09 Replacement Activities The following Unit 1 Owner's Report of Repairs or Replacements, form NIS-2, have been prepared by the ISI Program Owner and certified by the Authorized Nuclear Inservice Concrete Inspector (ANIC):
Work Order Number Description
- 1. 99183933 Replace Snubber Assembly
- 2. 99183935 Replace Snubber Assembly
- 3. 99248478 Replace Snubber Assembly
UNIT 2 Amended Table E L2R09 Replacement Activities The following Unit 2 Owner's Report of Repairs or Replacements, form NIS-2, has been prepared by the ISI Program Owner and certified by the Authorized Nuclear Inservice Concrete Inspector (ANIC):
Work Order Number Description
- 1. 99234572 Replace Snubber Assembly
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl
- 1. Owner Exelon Generation Company (EGC) LLC Date 11121/00 (Name) 200 Exelon Way. Kenneth Square. PA., 19348 Sheet 1 of I Address
- 2. Plant LaSalle Countv Nuclear Station Unit 2 Name 2601 N. 21"t Rd. Marseilles. II. 61341 W.-0 # 9912R403f (Address) Repair Organization, P.O. No., Job No., etc.
- 3. Work Performed bIi MUhnn1,ca Mnlnftannn- Type Code Symbol Stamp- NIA M1-(Name) A-U-2-1-lz PULI1IUI&OLIUII 1lU.
LIPA 5I/
Mechanical Maintenance Expiration Date. NIA (Address)
- 4. Identification of System (MS) Main Steam
- 5. (a) Appiicable Construction Code ANSI B31.7 19 69 Edition No Addenda, Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements-1989 . No Ad, Code Cases None
- 6. Identification of Comoonents Reoalred or Replaced, and Replacement Comoonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
(1) Load Stud Pacific NIA MSO6-2803S Replaced NIA Scientific (1) Load Stud Pacific 4R4010 NIA L94-00450 1994 Replacement N/A I Scientific I I _III
- 7. Description of Work: Class 1 Reolacement of Mechanical Snubber Load Stud Assembly.
- 8. Tests Conducted: Hydrostatic I I Pneumatic II Normal Operating Pressure I I Other Visual Pressure asl Test Temp._. Deg. F
- 9. Remarks: * = Per Orlalnal Deslan Snecification J-2530.
(Applicable Manufacturer's Data Report to be Attached )
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this_ Replacement conforms to the rules of the ASME Code,Section XI. (repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No. KIA Ir, C-nlnr-inn nfDl P.--.ru vv.. N/A Signed t -- ISI Coordinator Date o___ t__ 2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L2R07 to L2R08 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty ,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
, A 1/'1A Inspectp9s Signature t1/22- .. Commissions IL 1927 National Board, State, Province, and Endorsements Date d- / 2 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1. Owner Exelon Generation Company (EGC) LLC Date 11/18/00 (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Sheet 1 of 1 Address
- 2. Plant LaSalle County Nuclear Station Unit 2 Name 2601 N. 21' Rd. Marseilles. II. 61341 (Address) Repair Organization, P.O. No., Job No., etc.
- 3. Work Performed b'V Urhan~leal M.lnfena... Type Code Symbol Stamp- N/A (Name) Authorization No. N/A Mechanical Maintenance Expiration Date N/A (Address)
- 4. Identification of System (RH) Residual Heat Removal
- 5. (a) Applicable Construction Code ANSI B31.1 19 73 Edition S74 Addenda, Code Cases None (b) Applicable Edition of Section XI Utilized for Repairs or Replacements-1989 , No Ad, Code Cases None
- 6. Identification of Comnonents Renalred or Renlaced. and Renlacement Comoonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
(1)- Load Stud PSA N/A RH40-2882S Replaced N/A Assy __ __ __ _____19Rlen _
(1)- Load Stud Grinnell 4N5098 NIA RH40-2882S 1999 Replacement N/A Assy I __ __ I_ I__II__II
- 7. Description of Work: Class 2 Replacement of Load stud assembly for a Mechanical Snubber.
- 8. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I I Other Visual Pressure psl Test Temp.___Deg. F
- 9. Remarks: * = Per Original Design Specification J-2530.
(Applicable Manufacturer's Data Report to be Attached)
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this_ Replacement conforms to the rules of the ASME Code,Section XI. (repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No. - KIIA I.,r.
r LAjJaWJ.. *J-n+
%l~~# N/A Slgnedf*e eC K ISI Coordinator Date ec6 /3 / 2004 Owner or Owner's Designee, Title 7 CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler lnsp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L2R07 to L2R08 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner foranypersonal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
,A&, dCommissions IL 1927 InsB or's Signature National Board, State, Province, and Endorsements Date R /3 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xl
- 1. Owner Exelon Generation Companv (EGC) LLC Date 01112/02 (Name) 200 Exelon Way. Kenneth Square. PA.. 19348 Sheet I of 1 Address
- 2. Plant LaSalle County Nuclear Station Unit I Name 2601 N. 21'" Rd. Marseillies. II. 61341 W.O. # 99183933 (Address) Repair Organization, P.O. No., Job No., etc.
- 3. Work Performed by Mechanical Maintenance Type Code Symbol Stamp. N/A (Name) Authorization No. NIA I II~I IVII.
MULvIldilModi
IdlIU MISIMU11MIL.41 nlNn- I L;AI.J1dUUII LJO_____________________
- 4. lelnt~~rn-n nf-Ret IUt:lilillUdllUII Up Cyan (RR) Reactor Recirculation
- 5. (a) Applicable Construction Code ANSI B31.7 19 69 Edition No Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 No Ad, Code Cases None A Idintifientinn.. nf Cnmnnnnntq Reialred or Rnilarpd- and Renlacpment
____________nd_l rz Comnonnnts w ____________-o Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Mechanical Pacific 7232 NIA RR0O-1 032S Replaced N/A Snubber Scientific Hydraulic lsega 61279129 NIA RROO-1 032S 2002 Replacement NIA Snubber I I I _II
- 7. Description of Work: Class I Replacement of Mechanical Snubber Assembly.
- 8. Tests Conducted: Hydrostatic I I Pneumatic Il I Normal Operating Pressure I I Other Visual Pressure -- psi Test Temp.__Deg. F
- 9. Remarks: * = Per Original Design Specificatlon J-2530.
(Applicable Manufacturer's Data Report to be Attached )
CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this_ Replacement conforms to the rules of the ASME Code,Section XI. (repair or replacement)
Type Code Symbol Stamp NONE Certificate of Authorization No. UIA IMIM . . . . . . . . . . r J.JIIOUULWL-
.V-A1J9 IO Li VI I LJO&W NIA qlenpei - Z. ISI Coordinator Date ° /A/ 2004
_--- ', I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Insy. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LJR08 to LIR09 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements-of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty , expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
CCommissions IL 1927 I 2 zfector's Signature National Board, State, Province, and Endorsements Date / - 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1. Owner Exelon Generation Company (EGC) LLC Date 01/19102 (Name) 200 Exelon Way, Kenneth Square. PA.. 19348 Sheet 1 of I Address
- 2. Plant LaSalle County Nuclear Station Unit I Name 2601 N. 21t Rd. Marseilles. II. 61341 W.O. # 99183935 (Address) Repair Organization, P.O. No., Job No., etc.
- 3. IAI-A, DA 1-e vwouI% Irenorrne61u 9yJ an al caialmleac an- -t -ifa -- -
Type Code Symbol Stamp_ NIA (Name) Authorization No. N!A Mechanical Maintenance Expiration Date_ NIA (Address)
- 4. Identification of System 1RH) Residual Heat Removal
- 5. (a) Applicable Construction Code ANSI B31.7 19 69 Edition No Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1 989, .No Ad, Code Cases None
- 6. Identification of Components Repalred or Replaced, and Replacement Components Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Mechanical Pacific N/A RH04-1 508S Replaced NIA Snubber Scientific .
Hydraulic Llsega 61344/86 NIA RH04-1508S 2002 Replacement NIA A Snubber II I _I
- 7. Description of Work: Class 1 Replacement of Mechanical Snubber Assembly.
S. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure l I Other Visual Pressure psi Test Temp.___Deg. F
- 9. Remarks: * = Per Original Desian Specification J-2530.
(Applicable Manufacturer's Data Report to be Attached )
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. (repair or replacement)
Type Code Symbol Stamp NONE Certificate of thorization No. NIA -Expiration Date NIA Slaned ISI Cnnrdinatnr Date ' _ _ _ 2004 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period LIR08 to LIR09 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty , expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
Coosmissions IL 1927 Inspector" gnature National Board, State, Province, and Endorsements Date ye_ z2- 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section Xi
- 1. n--~
-we
- .. C-1 zll
_-.1~ll tvlnFnr~n lrdlw 61- nv{r 1-1s I-oI r. Date 01128102 (Name) 200 Exelon Wav. Kenneth Sauare. PA.. 19348 Sheet 1 of 1 Address
- 2. Plant LaSalle County Nuclear Station Unit 1 Name 2601 N. 21" Rd. Marseilles. II. 61341 W.O. # 99248478 (Address) Repair Organization, P.O. No., Job No., etc.
- 3. Work Performed k- %Aehnlea- - - - - - Type Code Symbol Stamp N/A (Name) Authorization No. N/A Mechanical Maintenance Expiration Date_ N/A (Address)
- 4. Identification of System (RR) Reactor Recirculation
- 5. (a) Applicable Construction Code ANSI 631.7 19 69 Edition No Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 , No Ad, Code Cases None IdenfIfleratinn of Comnnnnnts Reralred or RPntacePd and Renlacrment Cnmrnonanft Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Mechanical Pacific 37716 N/A RR17-1007S
- Replaced N/A Snubber Scientific Mechanical Pacific 37741 N/A RR17-1007S 1994 Replacement N/A Snubber Scientific I
- 7. Description of Work: Class 1 Reolacement of Mechanical Snubber Assembly.
- 8. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I I Other Visual Pressure psl Test Temp.__ Deg. F
- 9. Remarks: * = Per Orlainal Design Specification J-2530.
(Applicable Manufacturer's Data Report to be Attached)
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this Replacement -conforms to the rules of the ASME Code, Section Xl. (repair or replacement)
Type Code Symbol Stamp NONE Certificate of Auth IzatIon No. N/A .Expiratlon Date N/A Sinned
- in *
- _ _ _ - _ _ _ -
j 1s1 arQnnn
.o, .
buululll>zul Date 2004 e
Owner or Owner's Designee, Title .I CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boiler Insp. & Ins. Co. of Connecticut have Inspected the components described In this Owner's Report during the period L1R08 to LIR09 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the Inspector nor his employer makes any warranty ,expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner forany personal injury or property damage or a loss of any kind arising from or connected w nspection.
7 4Z Commissions IL 1927 1 spor's Signature National Board, State, Province, and Endorsements Date ______ _ 2004
FORM NIS-2 OWNER'S REPORT OF REPAIRS OR REPLACEMENTS As Required by the Provisions of ASME Code Section XI
- 1. Owner Exelon Generation Company (EGC) LLC Date 01122103 (Name) 200 Exelon Way. Kenneth Square, PA.. 19348 Sheet I of I Address
- 2. Plant LaSalle County Nuclear Station Unit 2 Name 2601 N. 21" Rd. Marseilles. ii. 61341 WA # 99234572 (Address) Repair Organization, P.O. No., Job No., etc.
- 3. Work Performed Ibv MnRhAnlrel Matnton.nr. Type Code Symbol Stamp- NIA (Name) Authorization No. NIA Mechanical Maintenance Fynlratinn Dlafp NIA (Address)
- 4. Identification of System (RR) Reactor Recirculation
- 5. (a) Applicable Construction Code ANSI B31.7 19 69 Edition No Addenda, Code Cases None (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements-1989 . No Ad, Code Cases None S. Identification of Comnonents Renalred or Renlaced. and Renlacement Comnonents Name of Name of Mfrs. Ser. Nat'l Other Year Repaired ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Mechanical Pacific 2726 NIA RROO-2032S Replaced N/A Snubber Scientific Hydraulic Llsega 61359152 N/A RROO-2032S 2002 Replacement N/A Snubber .
Description of Work: Class 1 Renlacement of Mechanical Snubber Assembly.
- 8. Tests Conducted: Hydrostatic I I Pneumatic I I Normal Operating Pressure I_
Other Visual Pressure psl Test Temp.__Deg. F
- 9. Remarks: * = Per Orialnal Deslan Soecification J-2530.
(Applicable Manufacturer's Data Report to be Attached )
CERTIFICATION OF COMPLIANCE We certify that the statements made In the report are correct and this_ Replacement conforms to the rules of the ASME Code,Section XI. (repair or replacement)
Type Code Symbol Stamp NONE Certificate of Aorization No. L11A RI-r InlrStlin cxpAIIOLIicr LIOLC Wale NIA SignedC- ._ ISI Coordinator Date Z) Cf X / 2004 Owner or Owner's Designee, Title a CERTIFICATE OF INSERVICE INSPECTION I, The undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of Illinois and employed by The Hartford Steam Boller Inso. & Ins. Co. of Connecticut have inspected the components described in this Owner's Report during the period L2R08 to L2R09 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty , expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection.
4P, / & Commissions IL 1927 Insp r's Signature National Board, State, Province, and Endorsements Date _ _ 2004
\