Exe onM Exelon Generation Company, LLC www.exeloncorp.com Nuclea LaSalle County Station 2601 North 21"1Road Marseilles, IL 61341-9757 June 9, 2003 10 CFR 50.46 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 LaSalle County Station, Units 1 and 2 Facility Operating License Nos. NPF-1 1 and NPF-18 NRC Docket Nos. 50-373 and 50-374
Subject:
Plant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report
Reference:
Letter from M. A. Schiavoni (Exelon) to U.S. NRC, Plant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report,"
dated June 8, 2002.
In accordance with 10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors," Exelon Generation Company (EGC), LLC, submits the enclosed attachments to fulfill the annual reporting requirement for LaSalle County Station, Units 1 and 2. The previously calculated Peak Cladding Temperature (PCT) of 1301 degrees Fahrenheit (F) for General Electric (GE) fuel and 1827°F for Framatome-ANP (FANP) fuel were reported in Reference 1. The PCT for GE fuel increased by 35°F to a value of 1336°F, while the PCT for FANP fuel increased by 5°F to a value of 1832°F.
Unit I employs a mixed core design containing co-resident GE and SPC fuel.
Unit 2 employs a core design containing only SPC fuel. The Loss of Coolant Accident (LOCA) analyses of record for both GE and SPC fuel are within all of the acceptance criteria set forth in 10 CFR 50.46.
Attachments 1 and 2 provide PCT information for the limiting LOCA evaluations for LaSalle County Station, Units 1 and 2, including all assessments as of May 1, 2003. The assessment notes are contained in Attachment 3 and provide a detailed description for each change or error reported.
June 9, 2003 U.S. Nuclear Regulatory Commission Page 2 Should you have any questions conceming this letter, please contact Mr. Glen Kaegi, Regulatory Assurance Manager, at (815) 415-2800.
Respectfully, Susan R. Landahl Plant Manager LaSalle County Station Attachments cc: Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - LaSalle County Station
Attachment I LaSalle Units I and 2 10 CFR 50.46 Report (GE Fuel)
PLANT NAME: LaSalle Units 1 and 2 ECCS EVALUATION MODEL: SAFERJGESTR LOCA REPORT REVISION DATE: May 9, 2003 CURRENT OPERATING CYCLES: L1CIOA and L2C10 ANALYSIS OF RECORD Evaluation Model Methodology: "GESTR-LOCA and SAFER Models for the Evaluation of the Loss-of-Coolant Accident," Volumes , 11 and III, NEDE-23785-1-P-A, dated February 1985.
Calculation: "Project Task Report, LaSalle County Station, Power Uprate Evaluation, Task 407: ECCS Performance," GE report number GE-NE-Al 300384-39-01, Revision 1, dated September 1999.
Fuel: GE8x8NB (GE9)
Limiting Single Failure: HPCS Diesel Generator Limiting Break Size and 1.0 Double Ended Guillotine of Recirculation Pump Suction Location: Piping Reference PCT: 1301F MARGIN ALLOCATION A. PRIOR LOCA MODEL ASSESSMENTS 10 CFR 50.46 Report dated June 12, 2000 (see Note 1) APCT = 0 F 10 CFR 50.46 Report dated June 8, 2001 (see Note 2) APCT = 0 OF 10 CFR 50.46 Report dated June 8, 2002 (see Note 7) APCT = 0 F Net PCT 1301 F B. CURRENT LOCA MODEL ASSESSMENTS SAFER Core Spray Injection Elevation Error (9) APCT = 25 F SAFER Bulk Water Level Error (10) APCT = 10 F GESTR Input File Interpolation Error (11) APCT = 0 F SAFER04 Computer Plafform Change (12) APCT = 0 F WEVOL S1 Volume Error (13) APCT = OF Unit 2 Jet Pump Riser Leakage (14) APCT= OF Unit I Mid-Cycle Reload (17) APCT = 0 F Total PCT Change from Current Assessments YAPCT = 35 °F Cumulative PCT Change from Current Assessments I APCT =35 F Net PCT 1336 OF
Attachment 2 LaSalle Units I and 2 10 CFR 60.46 Report (FANP Fuel)
PLANT NAME: LaSalle Units 1 and 2 ECCS EVALUATION MODEL: EXEM BWR Evaluation Model REPORT REVISION DATE: May 9, 2003 CURRENT OPERATING CYCLE: LlCIOA and L2C10 ANALYSIS OF RECORD Evaluation Model Methodology: Advanced Nuclear Fuels Corporation Methodology for Boiling Water Reactors EXEM BWR Evaluation Model, ANF 048(P)(A), January 1993.
BWR Jet Pump Model Revision for RELAX, ANF 048(P)(A), Supplement I and Supplement 2, Siemens Power Corporation, October 1997.
Calculation: 1. LaSalle LOCA-ECCS Analysis MAPLHGR Limits for ATRIUM Th -9B Fuel, EMF-2175(P), March 1999.
- 2. LOCA Break Spectrum Analysis for LaSalle Units I and 2, EMF-2174(P), March 1999.
- 3. LaSalle Units 1 and 2 LOCA-ECCS Analysis MAPLHGR Limit for ATRIUMy-10 Fuel, EMF-2641(P), November 2001.
- 4. LaSalle Units I and 2 LOCA Break Spectrum Analysis for ATRIUMTm-10 Fuel, EMF-2639(P), November 2001.
Fuel: ATRIUMT-9B and ATRIUM T m-10 Limiting Fuel ATRIUM Tm-9B Limiting Single Failure: HPCS Diesel Generator Limfting Break Size and Location: 1.1 f 2 Recirculation Pump Discharge Side Line Break Reference PCT: 1807 "F MARGIN ALLOCATION x DDU1 I ^^A EflnCl ACCCCUI:RT
. F-iI%O %.I V% 5IU b6L.L. I I a 10 CFR 50.46 report dated May 7, 1999 (See Note 3) APCT = 0 F 10 CFR 50.46 report dated February 20, 2000 (See Note 4) APCT =18 F 10 CFR 50.46 report dated June 12, 2000 (See Note 5) APCT = 0 F 10 CFR 50.46 report dated June 8, 2001 (See Note 6) APCT = 0 F 10 CFR 50.46 report dated June 8, 2002 (See Note 8) APCT = 2 F Net PCT 1827 F
- 6. CURRENT LOCA MODEL ASSESSMENTS Unit 2 Jet Pump Riser Leakage (14) APCT = 0 F Unit 2 Cycle 10 Reload Fuel (15) APCT = 0 F Incorrect Calculation of Junction Inertia (16) APCT = 5 F Unit I Mid-Cycle Reload (17) APCT = 0 F Total PCT Change from Current Assessments EAPCT = 5 F Cumulative PCT Change from Current Assessments I I APCT = 5 F Net PCT 1832 F
Attachment 3 LaSalle Units I and 2 10 CFR 50.46 Report Assessment Notes
- 1. Prior LOCA model assessment for GE fuel The reference leter reported a new analysis of record for GE fuel as a result of the mid-cycle power uprate to 3489 MWt during Unit 1 Cycle 9 and Unit 2 Cycle 8.
[
Reference:
Leter from C.G. Pardee (ComEd) to U.S. NRC, PIant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report," dated June 12, 2000.]
- 2. Prior LOCA model assessment for GE fuel The reference letter assessed impact of Unit 2 LPCS riser leakage and errors in GE LOCA analysis model.
[
Reference:
Letter from M.A Schiavoni (Exelon) to U.S. NRC, "Plant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report,* dated June 8, 2001.]
- 3. Prior LOCA Model Assessment for FANP fuel The May 1999 LOCA model assessment was a new analysis of record for Framatome (Formerly Siemens) due to the introduction of ATRIUM-9B fuel into the Unit 2 Cycle 8 core. Therefore, there is no PCT change. Analysis was performed for a core power of 3722 MWt that bounds the current uprated power of 3489 MWt.
[
Reference:
Letter from J. A. Benjamin (CornEd) to U.S. NRC, Report of Significant Change in Calculated Peak Cladding Temperature (PCT) - 10CFR 50.46 Report," dated May 7, 1999.]
- 4. Prior LOCA Model Assessment for FANP fuel The February 2000 50.46 report assessed the impact of errors in the LOCA evaluation model.
[
Reference:
Letter from J. A. Benjamin (ComEd) to U.S. NRC, *Plant Specific ECCS Evaluation Changes - 10CFR 50.46 Report," dated February 9, 2000.]
- 5. Prior LOCA Model Assessment for FANP fuel The June 2000 10 CFR 50.46 report does not have any PCT assessment for ATRIUM-9B fuel.
[
Reference:
Letter from C. G. Pardee (CornEd) to U.S. NRC, "Plant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report," dated June 12, 2000.]
- 6. Prior LOCA model assessment for FANP fuel The reference leter assessed impact of Unit 2 LPCS riser leakage, errors in FANP LOCA analysis model and Unit 2 Cycle 9 reload fuel.
[
Reference:
Letter from M. A Schiavoni Exelon) to U.S. NRC, "Plant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report," dated June 8, 2001.]
Attachment 3 LaSalle Units I and 2 10 CFR 50.46 Report Assessment Notes
- 7. Prior LOCA model assessment for GE fuel The reference letter reported no new model error for the GE LOCA analysis, thus no change to PCT.
[
Reference:
Letter from M. A Schiavoni (Exelon) to U.S. NRC, Plant Specific ECCS Evaluation Changes - 10 CFR 50.46 Report," dated June 8, 2002.]
- 8. Prior LOCA model assessment for FANP fuel The reference letter assessed impact of errors in FANP LOCA analysis model, Unit I Cycle 10 reload fuel and ATRIUM-9B exposure extension.
[
Reference:
Letter from M. A Schiavoni (Exelon) to U.S. NRC, Pant Specific ECCS Evaluaton Changes - 10 CFR 50.46 Report,' dated June 8, 2002.]
- 9. SAFER Core Spray Injection Elevation Error GE reported an error in the automation code that prepares the input basedeck for the SAFER analysis. This error resulted in too low a value calculated for the injection elevation for the lower Core Spray sparger. GE determined the PCT impact for this error to be an increase of 25°F.
[
Reference:
10 CFR 50.46 Notification Letter, 2002-01, Issued by Glen A. Watford, no date shown.]
- 10. SAFER Bulk Water Level Error GE reported that the initial vessel water level used in the SAFER LOCA analysis did not properly account for the effect of the steam dryer pressure drop on the initial inventory of water in the vessel. The SAFER code used the indicated water level as the initial level, which resulted in too high an initial liquid inventory. GE determined the PCT impact for this error to be an increase of 10°F.
[
Reference:
10 CFR 50.46 Notification Letter, 2002-02, Issued by Glen A. Watford, no date shown.]
- 11. GESTR Input File Interpolation Error GE reported that an error in the initial gap conductance for cases at or beyond the knee in the LHGR curve. Due to this error, the initial gap conductance used in the SAFER calculations was slighUy lower than it should have been. GE determined that the PCT impact of this error to be negligible.
[
Reference:
10 CFR 50.46 Notification Letter, 2002-03, Issued by Glen A. Watford, August 26, 2002.]
Attachment 3 LaSalle Units I and 2 10 CFR 60.46 Report Assessment Notes
- 12. SAFER04 Computer Plafform Change GE reported that the LOCA evaluation code SAFER04 has been migrated from the VAX computer platform (SAFER04V) to the Alpha computer platform (SAFER04A). The change in computer platform may result in a change in the calculated peak cladding temperature (PCT) due to changes in the processor word size and FORTRAN compiler characteristics. GE determined that the PCT impact of this error to be negligible.
[
Reference:
10 CFR 50.46 Notification Letter, 2002-04, Issued by Glen A. Wafford, August 26, 2002.]
- 13. WEVOL SI Volume Error GE reported that an error was found in the WEVOL code, which affects the calculated vessel volume in the downcomer region. The free volume in the region of the shroud head is calculated incorrectly. The code did not properly account for the volume of the standpipes inside the shroud head thickness. This resulted in the value for the free volume in the downcomer being too small by 4-10 ft3. GE determined that the PCT impact of this error to be negligible.
[
Reference:
10 CFR 50.46 Notification Letter, 2002-05, Issued by Glen A. Watford, August 26, 2002.]
- 14. Unit 2 Jet Pump Riser Leakage The referenced letter assessed impact of the leakage due to jet pump riser flaw identified through the latest inspection at LaSalle Unit 2. There is no impact on PCT due to the jet pump riser leakage.
[
Reference:
Impact of Unit 2 Jet Pump Riser Leakage on LaSalle LOCA analysis,'
NF:MW:03-055, February 7, 2003.1
- 15. Unit 2 Cycle 10 reload fuel LOCA analysis for the new fuel type (ATRIUM-1 0) shows its PCT to be less than the PCT of the limiting fuel type (ATRIUM-9B). Therefore, the PCT change is reported as 0°F.
[
Reference:
- LaSalle Unit 2 Cycle 10 Reload Analysis," EMF-2830, Revision 0, Framatome ANP, January 2003.]
- 16. Incorrect Calculation of Inertia Terms for Recirculation Pump Discharge Break Junctions Framatome reported that an error was found in the junction inertia value calculated for recirculation pump discharge break. Framatome determined the impact of this error on the limiting PCT for ATRIUM-9B fuel is an increase of 50F.
[
Reference:
Letter from A. W.Will (Framatome ANP) to F.W. Trikur (Exelon),
- Transmittal of 10CFR50.46 Reporting for LaSalle Units," AWW:03:034, March 28, 2003.]
Attachment 3 LaSalle Units I and 2 10 CFR 50.46 Report Assessment Notes
- 17. Unit 1 Mid-Cycle Reload (ClOA)
LaSalle Unit I was shutdown on May 18, 2002 to perform in core fuel sipping to identify the location of failed fuel. Three failed assemblies were replaced. LOCA analysis was assessed for the change and there was no PCT impact.
[
References:
LaSalle 1 Cycle 1OA Reload Package," NFM-MW:02-0176, May 23, 2002.
Letter from D.E. Garber (Framatome ANP) to F.W. Trkur (Exelon), "Licensing Letter Report for Impact of Revised Core Loading on LaSalle 1 Cycle 10 Licensing,"
DEG:02:094, May 23, 2002.]