MONTHYEARML20217J3751999-10-15015 October 1999 Informs That Applicable Portions of NEDC-32778P, Safety Analysis Rept for River Bend 5% Power Uprate, Marked as Proprietary Will Be Withheld from Public Disclosure Pursuant to 10CFR2.790(b)(5) & Section 103(b) Project stage: Other ML0232502012002-11-15015 November 2002 License Amendment Request Pursuant to 10 CFR 50.90: Revision of Reactor Pressure Vessel Pressure-Temperature Limits and Request for Exemption from Requirements of 10 CFR 50.60 Project stage: Request ML0236501962002-12-31031 December 2002 Additional Questions Re 11/15/02 Amendment Request Project stage: Other ML0302900562003-01-15015 January 2003 Transmittal of Neutron Transport Calculations Benchmarking Report Project stage: Request ML0307704482003-03-0606 March 2003 Inservice Inspection Relief Requests Regarding Inner Radius Examination of Class I Reactor Pressure Vessel Nozzles Project stage: Request ML0311401882003-04-23023 April 2003 P-T Limits Amendment Project stage: Other ML0311402082003-04-24024 April 2003 NMP1 P-T Limits Curve Amendment - Issues for Discussion Project stage: Other ML0312603012003-05-0606 May 2003 Request for Additional Information - Amendment Application Pressure-Temperature Limit Curves Project stage: RAI ML0314001372003-05-16016 May 2003 Current Active Action List Project stage: Other ML0317702342003-06-18018 June 2003 Change to Commitment Date for Response to Request for Additional Information - Amendment Application Pressure-Temperature Limit Curves (TAC No.MB6687 & MB6703) Project stage: Response to RAI ML0319600782003-07-14014 July 2003 Draft RAI Re. Nine Mile Point 03/06/2003 Request for Relief Project stage: Draft RAI ML0320504542003-07-24024 July 2003 Issuance of License Amendment No. 136, Reactor Vessel Material Surveillance Program Project stage: Approval ML0322505952003-07-31031 July 2003 Response to Request for Additional Information Pressure-Temperature Limit Curves Project stage: Response to RAI ML0324006252003-08-19019 August 2003 Withdrawal of Request for Exemption from the Requirements of 10 CFR 50.60 Regarding an Alternate for Developing Reactor Pressure Vessel Pressure-Temperature Limits Project stage: Withdrawal ML0326810102003-09-15015 September 2003 Transmittal of Revised Neutron Transport Calculations Benchmarking Report Project stage: Request ML0327606962003-10-27027 October 2003 License Amendment, Issuance of Amendment Re. Pressure Temperature Limit Curves Project stage: Approval RBG-46368, Additional Information Regarding River Bend Station Fluence Calculations2004-12-0808 December 2004 Additional Information Regarding River Bend Station Fluence Calculations Project stage: Other 2003-05-16
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24008A0592024-01-0808 January 2024 E-mail Dated 1-8-2024 from R. Guzman to R. Reynolds Correct TS Page 204 for License Amendment No. 250 Adoption of TSTF-505 ML24008A2622024-01-0808 January 2024 Acceptance Review Determination for Relief Request I5R-12, Concerning Installation of a FSWOL on RPV Recirculation Inlet Nozzle N2E Safe End-to-Nozzle Dissimilar Metal Weld ML23268A0022023-09-22022 September 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-264-A, Revision 0 ML23264A7992023-09-21021 September 2023 NRR E-mail Capture - Final RAI - Constellation Energy Generation, LLC Fleet Request License Amendment Request to Adopt TSTF-580, Revision 1 ML23255A2872023-09-12012 September 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Alternative to Use the Successive Inspection Requirements of BWRVIP-75-A ML23237B3972023-08-24024 August 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Alternative Request to Use Updated BWRVIP Guidelines ML23205A2432023-07-19019 July 2023 NRC Staff Follow-up Question on Audit Question 18 TSTF-505 and 50.69 Regulatory Audit (E-mail Dated 7/19/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23207A0762023-07-14014 July 2023 EN 56557 - Update to Part 21 Report Re Potential Defect with Trane External Auto/Stop Emergency Stop Relay Card Pn: XI2650728-06 ML23205A2412023-07-11011 July 2023 NRC Staff Follow-up Comments on Audit Questions 6a, 6b, and 6c TSTF-505 and 50.69 Regulatory Audit (E-mail Dated 7/11/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23205A2422023-07-11011 July 2023 NRC Staff Follow-up Comments on Audit Questions 17 and 19 TSTF-505 and 50.69 Regulatory Audit (E-mail Dated 7/11/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23209A7692023-06-14014 June 2023 Draft Audit Results File TSTF-505 and 50.69 (E-mail Dated 6/14/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23209A7672023-06-13013 June 2023 Share File Observations on Response to Question 06 and 22 TSTF-505 and 50.69 (E-mail Dated 6/13/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23163A2292023-06-12012 June 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-580, Revision 1 ML23159A0052023-06-0505 June 2023 56557-EN 56557 - Paragon - Redlined ML23149A0012023-05-29029 May 2023 Audit Agenda TSTF-505 and 50.69 (E-mail Dated 5/29/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23142A0222023-05-22022 May 2023 Regulatory Audit Questions (PRA) TSTF-505 and 50.69 (E-mail Dated 5/22/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23118A3882023-04-28028 April 2023 Regulatory Audit Questions TSTF-505 and 50.69 (E-mail Dated 4/28/2023) (EPIDs L-2022-LLA-0185 and L-2022-LLA-0186) ML23104A3472023-04-14014 April 2023 Verbal Authorization for Relief Request I5R-14, Proposed Alternative Associated with N2E Dissimilar Metal Weld Overlay Repair with Laminar Indication ML23093A1782023-04-0303 April 2023 E-mail from T. Loomis to R. Guzman Proposed Alternative to Utilize Specific Provisions of Code Case N-716-3 ML23090A1302023-03-31031 March 2023 Verbal Authorization for Relief Request I5R-11, Proposed Alternative Repair of Recirculation Inlet Nozzle N2E Dissimilar Metal Weld ML23087A2912023-03-28028 March 2023 Request for Additional Information (3/28/2023 E-mail) - Proposed Emergent I5R-11 Alternative Associated with a Weld Overlay on RPV Recirculation Nozzle N2E DM Weld ML23061A0522023-03-0202 March 2023 Request for Additional Information (3/2/2023 E-mail) - Proposed Alternative Associated with a Weld Overlay Repair to the Torus ML23047A3832023-02-15015 February 2023 (2-15-2023 Email from J. Nelson to R. Guzman) Long Island Power Authority and Long Island Lighting Company Request for Threshold Determination ML23033A0142023-02-0202 February 2023 E-mail Dated 2-2-2023 from R.Guzman to R.Reynolds Correction to Error in NMP1 TSTF-505 and 50.69 Audit Plan ML23019A3092023-01-19019 January 2023 Acceptance Review Determination License Amendment Request to Adopt 10 CFR 50.69 Categorization Process ML23019A3032023-01-19019 January 2023 Acceptance Review Determination License Amendment Requets to Adopt TSTF-505 ML23013A3332023-01-13013 January 2023 Acceptance Review Determination Proposed Alternative for Weld Overlay Repair to the Torus ML22354A2622022-12-20020 December 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Request to Use Certain Provisions of the 2019 Edition of the ASME BPV Code, Section XI ML22342B1462022-11-21021 November 2022 NRR E-mail Capture - Acceptance Review for TSTF 295A ML22314A2262022-11-10010 November 2022 E-mail Dated 11/10/2022 Relief Request Associated with Pump Periodic Verification Tests of Core Spray System Pumps ML22301A0902022-10-28028 October 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-301, Revision 2 ML22252A1522022-09-0909 September 2022 Acceptance Review Determination Partial Adoption of TSTF-568 to Revise TS 3.3.1 for Primary Containment Oxygen Concentration ML22207A0192022-07-26026 July 2022 (E-mail Dated 7/26/2022) Setup of Online Reference Portal for Revision to Alternative Source Term Calculation for MSIV and Non-MSIV Leakage ML22207A0122022-07-26026 July 2022 Acceptance Review Determination Revision to Alternative Source Term Analysis for Containment Leakage ML22200A0782022-07-19019 July 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request to Use Honeywell Mururoa V4F1 R Supplied Air Suits ML22194A9412022-07-13013 July 2022 Request for Additional Information Relief Request CS-PR-02 (7/13/2022 e-mail) ML22173A0802022-06-22022 June 2022 E-mail Dated 6/22/2022, Acceptance of Requested License Amendment Request to Revise Surveillance Requirements to Reduce Number of Fast Starts of EDGs ML22075A0362022-03-16016 March 2022 Acceptance Review Determination - Relief Request CS-PR-02 Associated with Pump Periodic Verification Test of Core Spray System Pumps, E-mail Dated 3/16/2022 ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML22020A0642022-01-13013 January 2022 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21320A3472021-11-16016 November 2021 Request for Additional Information LAR to Revise TSs to Adopt TSTF-582, Revision 0 ML21306A3312021-11-0202 November 2021 Request for Additional Information Alternative Request GV-RR-10 (11/2/2021 e-mail) ML21301A0672021-10-28028 October 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-541 ML21298A0912021-10-25025 October 2021 E-mail Dated 10/25/2021, Acceptance of Requested License Amendment Request to Adopt Technical Specification Task Force Traveler 582 ML21292A2122021-10-19019 October 2021 NRR E-mail Capture - NRC Notification to the State of New York Regarding a Nine Mile Point Nuclear Station, Unit 2 Amendment - Adopt TSTF-501, Rev. 1 ML21278A6872021-10-0505 October 2021 Acceptance Review Determination - Relief Request GV-RR-10 ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21252A0482021-09-0707 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21215A3502021-08-0303 August 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-554 ML21168A3462021-06-17017 June 2021 Acceptance of Requested Licensing Action License Amendment Request - Adoption of TSTF-501, Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control (EPID L-2021-LLA-0096) (Email) 2024-01-08
[Table view] |
Text
From: Peter Tam To: INTERNET:Clyde.Mackaman@nmp.cn.com; INTernet:Denise.Wolniak@nmp.cn.com; internet:steven.leonard@nmp.cn.com Date: 4/24/03 8:44AM
Subject:
NMP1 P-T Limits Curve Amendment - Issues for Discussion Clyde:
Our Reactor Systems Branch has completed its review of your 11/15/02 application for amendment. Based on this review, we plan to approve your proposed use of the curves for 23.38 (in lieu of 28) EFPYs. If you agree, we would request that you revise all the curves with a label to limit their usefulness to 23.38 EFPYs, similar to what Pilgrim and Susquehanna did for similar amendments. If you disagree with this assessment and would like to pursue 28 EFPYs, we would be glad to discuss with you the following issues in a conference call:
Benchmarking - The licensee used the computer program DORT to calculate two-dimensional (r,z) and (r, ) flux distributions, and were combined to produce a three-dimensional flux (fluence) distribution. The cross sections were obtained from BUGLE-96. The BUGLE-96 values are derived from the ENDF/B-VI file, the recommended cross section set in RG 1.190. The licensee derived the neutron sources using the power distribution and the ORIGEN 2.1 code. It is not clear to the NRC staff why this code was used since fuel composition as a function of burnup should be available from reload reports or the licensee.
Poolside Critical Assembly (PCA) Benchmark - The arrangement analyzed has a 12-cm gap between the core and the thermal shield and a 13-cm gap between the thermal shield and the vessel. However, the core-to-shroud distances in Unit 1 range from 10 to about 40 cm and the shroud-to-vessel distance is about 40 cm. The arrangement chosen is not representative of a BWR geometry. In addition, the test excluded the Rh-103 and U-238 detectors. The licensees justification was that the Rh-103 detector is not commonly used due to its short half-life; therefore, the cross sections are not well known. Based on NUREG/CR-6115 (ORNL/TM-13205), the NRC staff disagrees with the justification provided. The licensees basis for rejecting the U-238 dosimeter was due to cross section difficulties. The purpose of benchmarking is to demonstrate the ability of the methodology as an integrated tool to calculate the dosimeter activation. Based on this review, the benchmarking appears not successful because it analyzed the wrong geometry and rejected dosimeters without a reasonable justification.
NMP1 Surveillance Capsule at 210-Degree Azimuthal - The NRC staff reviewed the NMP1 210-degree surveillance capsule report (the capsule was removed at the end of cycle 12 at 16.81 EFPYs). This report does not include any information on the methodology of neutronic calculations and in addition indicates substantial discrepancies between the Cu, Fe and Ni dosimeters. The report recommends the fluence value based on the Cu results, yet Cu activation represents a small part of the spectrum compared to Fe and Ni. Fe and Ni results are also available. Because the neutronic methodology was not presented and because of very large discrepancies in the dosimeter response, the NRC staff finds that the NMP1 210-degree surveillance capsule results do not support the benchmarking of the fluence calculational methodology.
Surveillance Capsules Used in the Proposed Benchmarking - The licensee removed, tested, and analyzed a total of 5 surveillance capsules from both Nine Mile Point units. However, only
two were proposed in the submitted benchmarking analysis. As stated in RG 1.190, one of the objectives of benchmarking is to determine potential bias in the calculation of the best estimate which requires that all of the existing data be used. This licensee ignored the existence of 3 Nine Mile Point capsules and made no effort to determine the existence of a bias. The benchmarking effort appears incomplete.
This e-mail aims solely to prepare you for a conference call. It does not formally state an NRC staff position, nor does it formally request for additional information.
Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 CC: Brian Fuller; Christopher Sydnor; Ed Knutson; Gordon Hunegs; Lambros Lois Mail Envelope Properties (3EA7DC12.638 : 10 : 20510)
Subject:
NMP1 P-T Limits Curve Amendment - Issues for Discussion Creation Date: 4/24/03 8:44AM From: Peter Tam Created By: PST@nrc.gov Recipients Action Date & Time Clyde Transferred 04/24/03 08:44AM Mackaman (INTERNET:Clyde.Mackaman@nmp.cn.
Denise Transferred 04/24/03 08:44AM Wolniak (INTernet:Denise.Wolniak@nmp.cn.c steven Transferred 04/24/03 08:44AM leonard (internet:steven.leonard@nmp.cn.c kp1_po.KP_DO Delivered 04/24/03 08:44AM BJF CC (Brian Fuller)
ECK CC (Ed Knutson)
GKH CC (Gordon Hunegs) owf2_po.OWFN_DO Delivered 04/24/03 08:44AM LXL1 CC (Lambros Lois) Opened 04/24/03 08:52AM nrc.gov
owf2_po.OWFN_DO Delivered 04/24/03 08:44AM CRS CC (Christopher Sydnor) Opened 04/24/03 09:08AM Post Office Delivered Route Clyde INTERNET:nmp.cn.c om Denise INTernet:nmp.cn.com steven internet:nmp.cn.com kp1_po.KP_DO 04/24/03 08:44AM owf2_po.OWFN_DO 04/24/03 08:44AM owf2_po.OWFN_DO 04/24/03 08:44AM nrc.gov Files Size Date & Time MESSAGE 5588 04/24/03 08:44AM Options Auto Delete: No Expiration Date: None Notify Recipients: Yes Priority: Standard Reply Requested: No Return Notification: None Concealed
Subject:
No Security: Standard To Be Delivered: Immediate Status Tracking: Delivered & Opened