TVA - Staff Exhibit 93 - Rec'D 05/02/02: TVA Oig Record of Interview of Wilson C. Mcarthur, October 29, 1996ML030920084 |
Person / Time |
---|
Site: |
Browns Ferry, Watts Bar, Sequoyah |
---|
Issue date: |
10/29/1996 |
---|
From: |
Tennessee Valley Authority |
---|
To: |
NRC/SECY |
---|
Byrdsong A T |
References |
---|
+adjud/ruledam200506, -RFPFR, 50-259-CIVP, 50-260-CIVP, 50-296-CIVP, 50-327-CIVP, 50-328-CIVP, 50-390-CIVP, ASLBP 01-791-01-CIVP, RAS 6212, TVA-Staff-93 |
Download: ML030920084 (3) |
|
|
---|
Category:Legal-Exhibit
MONTHYEARML15070A2992014-07-31031 July 2014 Official Exhibit - DTE000021-MA-CM01 - Excerpts from Draft NUREG-1437, Supplement 53, Generic Environmental Impact Statement for License Renewal of Nuclear Plants Supplement 53 Regarding Sequoyah Nuclear Plant, Units 1 and 2 (ADAMS No. ML14 IR 05000327/20100042011-12-12012 December 2011 Official Exhibit - NYS000029-00-BD01 - NRC Integrated Inspection Report 05000327/2010004, 05000328/2010004, Sequoyah Nuclear Plant (Oct. 29, 2010) (Sequoyah IR) ML1110911672011-04-19019 April 2011 Declaration of Dr Arjun Makhijani in Support of Emergency Petition to Suspend All Pending Reactor Licensing Decisions and Related Rulemaking Decisions Pending Investigation of Lessons Learned from Fukushima Daiichi Nuclear Power Station Acc ML0924608012009-09-0303 September 2009 Petitioner'S Amended Contention 7 Regarding TVA Aquatic Study ML0329404722003-04-17017 April 2003 TVA - Joint Exhibit 66 - Rec'D 09/13/02: April 17, 2002, Joint Stipulation Between TVA and Staff ML0310000092003-03-0404 March 2003 Joint Exhibit List (TVA Exhibits), Volumes 1 - 6 ML0310000102003-03-0303 March 2003 Tennessee Valley Authority'S Exhibit List, Volumes 1 - 11 ML0229801002002-10-18018 October 2002 Tennessee Valley Authority'S Response in Support of the Admission of TVA Exhibit No. 75 ML0227601262002-09-30030 September 2002 Tennessee Valley Authority'S Submission of Exhibits ML0226601012002-09-20020 September 2002 TVA - NRC Staff Redacted Documents ML0329501412002-09-12012 September 2002 TVA - Licensee Exhibit 94 - Rec'D 09/12/02: Corporate Nuclear Employees' 1996 Surplus Notices (Redacted) ML0307801352002-09-12012 September 2002 TVA - Licensee Exhibit 149 - Rec'D 09/12/02: Vacancy Announcement 66-21 ML0307101442002-09-12012 September 2002 TVA - Licensee Exhibit 86 - Rec'D 09/12/02: Watts BAR Nuclear Plant, Fy 1997 Workforce Planning Documents and Employees' 1997 Retention Registers (Redacted and Substituted) ML0307101022002-09-12012 September 2002 TVA - Licensee Exhibit 95 - Rec'D 09/12/02: Corporate Nuclear Employees' 1996 Retention Registers (Redacted and Substituted) ML0309700782002-09-11011 September 2002 TVA - Staff Exhibit 147 - Rec'D 09/11/02: DOL Brief in Support of Respondents Motion for Summary Decision ML0307801202002-09-11011 September 2002 TVA - Licensee Exhibit 144 - Rec'D 09/11/02: Resume of Heyward R. Rogers ML0307801152002-09-11011 September 2002 TVA - Licensee Exhibit 142 - Rec'D 09/11/02: Resume of H. Keith Fogleman ML0308501032002-09-10010 September 2002 TVA - Licensee Exhibit 148 - Rec'D 09/10/02: Cd Recording of a December 9, 1992 Conversation Between Gary L. Fiser and Robert J. Beecken ML0307801102002-09-10010 September 2002 TVA - Licensee Exhibit 141 - Rec'D 09/10/02: Resume of SAM L. Harvey ML0307801032002-09-10010 September 2002 TVA - Licensee Exhibit 140 - Rec'D 09/10/02: Resume of David F. Goetcheus ML0306500122002-09-10010 September 2002 TVA - Licensee Exhibit 14 - Rec'D 09/10/02: June 17, 1996, SAM Harvey Franklin Planner Note ML0307801002002-09-0909 September 2002 TVA - Licensee Exhibit 139 - Rec'D 09/09/02: Resume of Mark J. Burzynski ML0307800982002-09-0909 September 2002 TVA - Licensee Exhibit 138 - Rec'D 09/09/02: Resume of Robert J. Beecken ML0225501012002-09-0606 September 2002 Tennessee Valley Authority (TVA) - NRC Staff Supplemental Document List ML0224002582002-08-22022 August 2002 Tennessee Valley Authority'S Fifth Supplemental Exhibit List ML0309700412002-07-13013 July 2002 TVA - Staff Exhibit 128 - Rec'D 09/13/02: TVA Nuclear Corporate 1996 Reorganization Impact on Headcount ML0307800452002-06-18018 June 2002 TVA - Licensee Exhibit 133 - Rec'D 06/18/02: Organizational Chart, August 1996, Chemistry Program Manager (Pwr), Chemistry Program Manager (BWR) ML0309700362002-06-17017 June 2002 TVA - Staff Exhibit 124 - Rec'D 06/17/02: Vacant Position Announcement for Manager, Radiological Control, Closing Date August 31, 1994 ML0309006902002-06-17017 June 2002 TVA - Staff Exhibit 53 - Rec'D 06/17/02: NRC OI Interview of Ronald O. Grover, December 18, 1998 ML0309004132002-06-17017 June 2002 TVA - Staff Exhibit 49 - Rec'D 06/17/02: TVA Oig Record of Interview of Ronald O. Grover, July 11, 1996 ML0306500152002-06-13013 June 2002 TVA - Licensee Exhibit 12 - Rec'D 06/13/02: January 11, 1994, Investigation Insert (Oig File No. 20-135) (Ee 75, 79-82) ML0307800412002-06-12012 June 2002 TVA - Licensee Exhibit 132 - Rec'D 06/12/02: Chart Entitled Decision 'To Post' or 'Not to Post' ML0307802342002-05-0707 May 2002 TVA - Joint Exhibit 55 - Rec'D 05/07/02: September 25, 1996 Landers TVA Oig Record of Interview ML0307802032002-05-0202 May 2002 TVA - Joint Exhibit 45 - Rec'D 05/02/02: September 20, 1999 Notice of Apparent Violation to Mcarthur ML0309102222002-05-0101 May 2002 TVA - Licensee Exhibit 24 - Rec'D 05/01/02: Selection Package for Vpa No. 6621 (Hh 1-198) ML0307900182002-04-30030 April 2002 TVA - Joint Exhibit 27 - Rec'D 04/30/02: Fiser Sequence of Events ML0309707202002-04-30030 April 2002 TVA - Staff Exhibit 168 - Rec'D 04/30/02: Compact Disc Recording of Gary L. Fiser (Tape a, Side A/Section II) ML0309707332002-04-30030 April 2002 TVA - Staff Exhibit 169 - Rec'D 04/30/02: Compact Disc Recording of Gary L. Fiser (Tape I, Side A/Sec II, III, IV) ML0307800042002-04-30030 April 2002 TVA - Licensee Exhibit 112 - Rec'D 04/30/02: Tva'S Memorandum on the Admissibility of Depositions ML0329501492002-04-25025 April 2002 TVA - Licensee Exhibit 73 - Rec'D 04/25/02: Significant Corrective Action Report (Scar) No. SQSCA920004 (Cg 1-82) ML0309702652002-04-25025 April 2002 TVA - Staff Exhibit 130 - Rec'D 04/25/02: Organizational Chart for Nuclear Operations, Operations Support, Radiology and Chemistry Control, February 13, 1995 ML0309201322002-04-25025 April 2002 TVA - Staff Exhibit 99 - Rec'D 04/25/02: Employee Action Reasons for Wilson C. Mcarthur ML0307103452002-04-25025 April 2002 TVA - Licensee Exhibit 62 - Rec'D 04/25/02: Operations Support'S Organizational Overview (Bi 1-229), Chapters 1 - 7 ML0307103422002-04-25025 April 2002 TVA - Licensee Exhibit 62 - Rec'D 04/25/02: Operations Support'S Organizational Overview (Bi 1-229), Agenda - Operations Support Business Plan for Fiscal Year 1997 ML0306500732002-04-24024 April 2002 TVA - Licensee Exhibit 48 - Rec'D 04/24/02: January 20, 1994, Investigative Insert (Oig File No. 2D-135 (Aj 297-33 ML0330101752002-04-17017 April 2002 TVA - Joint Exhibit 67 - Rec'D 09/13/02: April 23, 2002, Joint Stipulation Between TVA and Staff ML0309700772002-04-0404 April 2002 TVA - Staff Exhibit 162 - Rec'D 06/19/02: Declaration of G. Donald Hickman, April 4, 2002 ML0306501202002-03-22022 March 2002 TVA - Licensee Exhibit 61 - Rec'D 09/12/02: 1996 Vacancy Posting System Intent ML0217705702002-02-20020 February 2002 Position Description for Radiological and Chemistry Control Manager ML0217603452002-02-20020 February 2002 Department of Labor Brief in Support of Respondent'S Motion for Summary Decision 2014-07-31
[Table view] |
Text
(2la 50-3q6-0 IVP424-- al Jha Edi'bi- q3 - GC g 5j1/6c; nnr'v1T;Fn UUITL I LuL TENNESSEE VALLEY AUTHORITY USNRC Office of the Inspector General, RECORD OF INTERVIEW 2003 MAR I I AM 11: 56 i
)FFICE 0. i4i i-.LCREIARY Ci RULE, ihKINGS AND ADJUDICATIONS STAFF A.,
Name: Wilson C. McArtter Position: Manager, RADobn Office: Chemistry Control Chattanoog& Tennessee Work Tel.: (423) 75.1f8715 Residence:
Home Tel.:
SSN/DOB:
McArthur was contacted at his office, advised of the identity of the interviewing agent, and reinterviewed concerning one specific issue involving a Department of Labor (DOL) complaint filed by Gary L. Fiser. McArthur furnished the following information.
McArthur was contacted to get specific information concerning the selection process used by the review board to fill two vacancies for program managers in the Chemistry Department. The vacancy position announcements (VPA) were numbers 10702 and 10703; 10702 was for the BWR Programri Manager position at Browns Ferry Nuclear Plant (BFN) and PWR was for the Program Manager position to handle Sequoyah (SON) and Watts Bar Nuclear Plants (WBN).
McArthur advised that the review board met on July 18, 1996, to conduct the interviews of the qualified applicants. The review board consisted of Charles Kent, Manager of Radiological and Chemistry Control at SON; John Corey, Manager of Radiological and Chemistry Control at BFN; and H.R. Rogers, Manager of Technical Support/Operations Support.
There were four qualified applicants for VPA 10702 and three applicants interviewed for VPA 10703.
Investigation On: October 29, 1996 At: Chattanooga, Tennessee By: David V. VanBocke4F1' File: 2D-169 - 3 3 28204 OIG-02 (10/93) - -
This document contains neither recommendations nor conclusions of the 01G. It is the property of the 0IG and is loaned to you. It and its contents should not be distributed outside of TVA without the permission of the Inspector General.
-TemupIa+-a zSC/'-y-8 SOOc;L
'ULiAR REGULATORY M, bo.
-e 50 - zq Oan,> . NoL ff`3 Inthe matter of /
Stat" __ IDENTIFIED Avre.ant RECEIVED _______
I xO;'^er_______ _ REJECTED _ ,_
C _______ .WITHDRAWN.
{DA: -/1210 . Witness -
./
'I
, L I
Continuation of Interview of William C. McArthur 2 McArthur advised that he prepared a series of questions that were used during the interview process by the review board. The review board was given the questions prior to conducting the interviews and selected anywhere from six to ten questions from the list of questions to be asked of each applicant. The same questions were asked of each applicant for each position.
McArthur said that he sat in during the interviews, however, he did not ask any questions and had no input during the interview process. Human Resource Officers (HRO) Ben Easley and Melissa Westbrook served as facilitators during the interview process.
At the end of the interview process, the HROs tabulated the scores from the review board members on the questions asked each applicant. They used a rating response of one to ten, ten being the highest rating to be given each applicant on the responses to the questions.
After all scores were tabulated, at the end of the interview process it was determined that E.S. Chandrasekaran received the highest rating by the review board for VPA 10702 which was the BWR position at BFN. Sam L. Harvey received the second highest rating for this position by the review board. Chandrasekaran had previously served in this position at BFN and had the most experience in the BWR plant.
McArthur was also told that Chandrasekaran received the highest score for VPA 10703, the PWR position at SON and WBN. Harvey was ranked second by the review board for this position. Fiser was ranked third by the review board.
Chandrasekaran had received the highest ranking for the BWR position and was the most qualified. The best choice was to keep Chandrasekaran at BFN. Because Harvey placed a close second for the PWR position, he was selected to fill the PWR position at SQNIWBN.
It was pointed out to McArthur that in reviewing the tabulations for the rated response for each question by the review board it was determined that an error had been made and Harvey actually received a slightly higher score than Chandrasekaran for the PWR position.
It was pointed out to McArthur that Harvey actually received a score totaling two-tenths of 1_percent higher than Chandrasekaran for the PWR position. McArthur was unaware of this error and felt it might have been an adding error performed during the tabulation of the scores. McArthur said that it did not affect the selection of Harvey to fill the PWR position.
McArthur said that the review board based the selection process on the responses provided by each applicant during the interview process. McArthur concurred with the rankings of the review board and requested that an offer be extended to both Harvey and Chandrasekaran for the vacant positions.