ML030870664

From kanterella
Jump to navigation Jump to search
Technical Specification Page for Amendment 254 to License DPR-62, Revising Safety Limit Minimum Critical Power Ratio Values from 1.09 to 1.11
ML030870664
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 03/25/2003
From: Mozafari B
NRC/NRR/DLPM/LPD2
To:
References
Download: ML030870664 (1)


Text

SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:

THERMAL POWER shall be

2.1.1.2 With the reactor steam dome pressure z 785 psig and core flow ; 10% rated core flow:

MCPR shall be ; 1.11 for two recirculation loop operation or

  • 1.13 for single recirculation loop operation.

2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.

2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be 5 1325 psig.

2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.

2.0-1 Amendment No. 254 Brunswick Unit 2