PAM Instrumentation 3.3.3.1 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D. Required Action and D.1 Enter the Condition Immediately associated Completion Time referenced in of Condition C not met.

Table 3.3.3.1-1 for the channel.

E. As required by Required E.1 Be in MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action D.l and referenced in Table 3.3.3.1 -1.

F. As required by Required F.1 Initiate action in accordance Immediately Action D.1 and referenced in with Specification 5.6.6.

Table 3.3.3.1-1.

SURVEILLANCE REQUIREMENTS


NOTE ----------------------------------------------------------

These SRs apply to each Function in Table 3.3.3.1-1.

SURVEILLANCE FREQUENCY SR 3.3.3.1.1 Perform CHANNEL CHECK.

31 days SR 3.3.3.1.2 (Not Used.)

(continued)

I Brunswick Unit 2 3.3-27 Amendment No. 261 I

PAM Instrumentation 3.3.3.1 SURVEILLANCE REQUIREMENTS (continued)

SURVEILLANCE FREQUENCY SR 3.3.3.1.3 Perform CHANNEL CALIBRATION for each required 24 months PAM Instrumentation channel.

I Brunswick Unit 2 3.3-28 Amendment No. 261 l

PAM Instrumentation 3.3.3.1 Table 3.3.3.1-1 (page I ot 1 Post Accident Monitoring Instrumentation CONDITIONS REFERENCED REQUIRED FROM REOURED FUNCTION CHANNELS ACTION D.1

1.

Reactor Vessel Pressure 2

E

2.

Reactor Vessel Water Level

a.

-150 inches to +160 inches 2

E

b.

0 inches to +210 inches 2

E

c.

+150inches to +550 inches 2

E

3.

Suppression Chamber Water Level 2

E

4.

Suppresslon Chamber Water Terrperalura 2

E

5.

Suppression Chanber Pressure 2

E

6.

Drywell Pressure 2

E

7.

Drywell Temperature 2

E

8.

PCIV PosItion 2 per penetration E

RawS path" N"

9.

(Not Used.)

10.

Drywall Area Radiation 2

F I

(a) Not required for isolatlIon valves whose essocdated penetraton flow path I isoated by at least one losed and deactivated automatic valve, closed nanual valve, blind flange, or check valve wIth fow through the valve secured.

(b) Only one position Incication channel I required for penetratfon flow paths with only one instaled contrd room indcatfon channel.

Brunswick Unit 2 3.3-29 Amendment No. 261 1