ML023500312

From kanterella
Jump to navigation Jump to search
Amergen TMI Emergency Plan Implementing Procedure EPIP-TMI-03, Revision 37, Emergency Notification and Call Outs
ML023500312
Person / Time
Site: Crane Constellation icon.png
Issue date: 12/02/2002
From:
AmerGen Energy Co
To:
Office of Nuclear Security and Incident Response
References
EPIP-TMI-03, Rev 37
Download: ML023500312 (54)


Text

  • Backup TSC,NOB-3
  • Bureau of Rad Protection Central File
  • Control Rm-U/1 File Cony. OOB-1 Control Rm - Shift Mers Office, OOB
  • Control Rm - CRS Workstation, OOB-1 Coatesville EOF, Kennett Square
  • Document Center, NOB-2

,*Document ControlDesk-Labelr......

EACC, EOF

  • EP - NDB, Trng. Bldg. #2
  • Emerg. Prep. Dept.
  • EP Drills, Trng. Bldg.

EP Rep, EOF ESD, EOF ESD Asst., EOF Environ. Affairs-TMI, NOB-1 GLRE&C, EOF Kennett EOF, Kennet Square Logisitcal Support, EOF

  • NRC - Onsite, Service Bldg.
  • NRC - Region 1, (Chief EP Section)
  • PEMA - Bureau of Plans PI Rep, EOF Personnnel/Vehicle Monitor Kit Trne Ctr.
  • Plant Maint. (Library). Serv. Bld2.

RLM, Rad Field Ops.

Rad Con -RAC Locker. Rad Field Ons.

Rad Con -Kit 1 PC. Rad Field Ons.

Rad Con -Kit 2 PC. Rad Field Ops.

Rad Con-Kit 3 EOF Bide Rad Field Ons Rad Con-Kit 4 EOF Blda Rad Field Ons.

Rad Con-Kit 5 EOF Bldg Rad Field Ops.

Rad Con-Simulator LockerRad Field Ops

  • Rad Engineers-Ul, OOB
  • Rad Instrument, Bldg. 159 Secondary Chem Lab-, OOB-1
  • Security Mgr., PC Security U-1, PC
  • Simulator Rm/File Copy Simulator Rm - Shift Mgrs Office
  • Simulator Rm - CRS Workstation Tech Support Rep
  • TSC - Unit 1, NOB-3
  • Training Dept. Library, Trng
  • OSC, Rad Field Ops..

Record Box, SOB + History Package B. Siebler M. Vyenielo D. Marshbank S. Van Ormer S. Van Ormer S. Van Ormer R. Rogers IKON

iNR, IKON N. D. Brown D. Light IKON IKON IKON N. D. Brown IKON IKON IKON W. Ressler IKON R. Rogers IKON P. Sauder N. McNama D. Fleck IKON T. Berstler J. Eckroth T. Berstler T. Berstler T. Berstler T. Berstler T. Berstler T. Berstler T. Berstler T. Berstler T. Griffith T. Griffith S. Van Ormer M. Bruecks M. Bruecks MON MON IKON N. D. Brown B. Siebler C. Flory T. Berstler S. Zimmerman INFO Plain 1

Plai__nn CTRL 1

1 CoXy 1

T A

C1 1_

1 1

1 1

2 1

1 1_!

1.!

1 EPIP/TEP Instruction Memo 9 4.*

Date I

'2Q! o!

Verif' 1

Box No.

TI 1 T2__

Please update your file with the attached listed below, destroy the superseded/cancelled document(s).\\.Also, if Controlled Documents please sign the acknowledgment at the bottom of this memo and return to Debbie Marshbank, Configuration Cntrl., Rm. 135, SOB Document Number e-T~L"--I Rev TC NUMBER Page Replac.

Entire TC/PROC Cld Level ADDITIONAL DISTRIBUTION:

I 3H C 311 I hereby acknowledge receipt of this memo and have complied with the instructions.

required ONLY if CONTROLLED.

Signature Procedure Distribution:

Info Copy A Stapled, 3 Hole Punch Ctrl Copy. Stapled, 3 Hole Punch Signature and returned memo Date Memo Distribution:

I Copies Plain Copy 2 Stapled (Central File & Record Box)

TC Distribution:

Plain Copies Stapled, 3-hole punch Plain Copy Stapled, 3-hole punch for Central File (if TC is original) 09/06/02

FOR INFORMATION ONLY Number Am erGen TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No.

Emergency Notifications and Call Outs 37 Applicability/Scope USAGE LEVEL Effective Date TMI Division 2

12102102 This document is within QA plan scope X

Yes No 50.59 Applicable LJ YesI X I No List of Effective Pages Paqe Revision Paqe Revision Page Revision Paqe Revision 1

37 41 37 2

37 42 37 3

37 43 37 4

37 44 37 5

37 45 37 6

37 46 37 7

37 47 37 8

37 48 37 9

37 49 37 10 37 50 37 11 37 51 37 12 37 52 37 13 37 53 37 14 37 15 37 16 37 17 37 18 37 19 37 20 37 21 37 22 37 23 37 24 37 25 37 26 37 27 37 28 37 29 37 30 37 31 37 32 37 33 37 34 37 35 37 36 37 37 37 38 37 39 37 40 37 I

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 1.0 PURPOSE

a.

To provide guidance in accomplishing initial notifications, reclassification notifications, and closeout notifications to off-site agencies.

b.

To provide guidance in accomplishing contact and call-out of emergency response personnel and facilities.

2.0 APPLICABILITY/SCOPE

a.

This procedure is applicable for all personnel performing notifications, contacts, and call-outs from the ECC.

b.

This procedure is to be used upon declaration of any emergency classification as specified in the Emergency Plan or when directed by the Emergency Director.

3.0 DEFINITIONS

a.

PEMARS - Pennsylvania Emergency Management Agency Radio System.

4.0 RESPONSIBILITIES

a.

Emergency Director Oversees implementation of this procedure Selects and approves Emergency Report Forms

b.

On-Shift ECC Communications Coordinator Initiates/completes notifications until relieved.

Initiates the call-out process.

Provides a turn-over to the Initial Response Emergency Organization Communicator.

Arranges for repairs of malfunctioning communications circuits until relieved by the Initial Response Emergency Organization Communications Coordinator.

2 NOTE The Off-Site Notification process may be TEMPORARILY reassigned to another qualified communicator during circumstances where the CRO/SRO's attention is required for plant operations.

Such reassignment should only occur under the most extreme conditions for initial plant stabilization and ONLY if a qualified alternative is already present in the Control Room The CRO-SRO ECC Communications Coordinator is expected to be available to continue notifications within 30 minutes of event declaration and shall be the individual performing the notification to the NRC on the ENS line, unless relieved by the IREO communicator.

TMI Emergency Plan Implementing Procedure Title Fmreraencv Notifications and Call Outs Number

  • 2

EPIP-TMI-.03 Revision No 37

c.

On-Shift Communicator Completes the call-out/contact process.

Provides a turn-over to the Initial Response Emergency Organization Communications Coordinator or Communicator.

d.

Initial Response Emergency Organization ECC Communications Coordinator Ensures initiation/completion of the notification and call-out processes Interfaces with the Emergency Director Assistant.

Arranges for repairs of malfunctioning communications circuits.

e.

Initial Response Emergency Organization Communicator Initiates/completes notifications until relieved.

Initiates/completes call-outs. The call-out process is not turned over to the EOF Communicators.

Provides a notifications status to the Emergency Support Organization Communicator.

NOTE Steps required to be performed more than once (e.g, at an Alert before an escalation, and at an Alert a second time due to a later reduction in classification) should be initialed for each time performed NOTE If communication system failures are experienced, refer to Exhibit 7, "Back Up Communications".

NOTE Steps that require the documentation of information are not required to have a signoff blank. Completion of the required data is sufficient documentation that the step has been completed.

3 NOTE Responsibility for performing off site notifications remains with the ECC Communicators and should not be turned over to the EOF Communicators except during extreme circumstances (e.g, evacuation of the ECC or failure of ECC telephones).

Emeraencv Notifications and Call Outs I

I

TMI Emergency Plan Implementing Procedure Emerqency Notifications and Call Outs Number EPIP-TMI-.03 Revision No 37 5.0 PROCEDURE 5.1 Upon declaration/reclassification of an emergency, complete the appropriate exhibit listed below:

a.

Unusual Event - Exhibit 1.

b.

Alert - Exhibit 2.

c.

Site Area Emergency - Exhibit 3.

d.

General Emergency - Exhibit 4 5.2 Upon termination of the incident, complete the appropriate following actions.

1.

If off-site notification responsibilities were not transferred to the EOF Communicators, THEN complete Exhibit 5, Closeout Notification Checklist, or

2.

If off-site notification responsibilities were transferred to the EOF Communicators, THEN confirm that the EOF Communicators are performing closeout notifications.

3.

Ensure the appropriate event termination steps in Exhibit 9, "Call-Out Operations", have been completed.

4.

Forward this procedure, all exhibits and associated paperwork to the Emergency Preparedness Department

6.0 REFERENCES

a.

EPIP-TMI-.06, Additional Assistance and Notification

b.

EPIP-TMI-.27, Emergency Operations Facility 7.0 EXHIBITS

a.

Exhibit 1 - Unusual Event Checklist b

Exhibit 2 - Alert Checklist

c.

Exhibit 3 - Site Area Emergency Checklist

d.

Exhibit 4 - General Emergency Checklist

e.

Exhibit 5 - Closeout Notification Checklist

f.

Exhibit 6 - Emergency Response Data System Activation

g.

Exhibit 7 - Back Up Communications

h.

Exhibit 8 - Emergency Status Log

i.

Exhibit 9 - Call-Out Operations 4

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT I Page 1 of 5 UNUSUAL EVENT CHECKLIST 1.0 Obtain an Emergency Report Form Part 1 and 2 from the Emergency Director or Shift Manager's computer printer.

NOTE Do not allow problems encountered in Step 2.0 to interfere with completion of the 15 minute off site notifications per Step 3.0. Steps 2 through 4 may be performed in parallel if manpower is available.

2.0 Activate the automated call out system.

2.1 Lift the EP Pager Call Out Phone receiver or press the "SPEAKER" button.

2.2 Press the applicable "LEVEL" button (designated on Part 1 of the Emergency Report Form, for the Unusual Event classification, the options are Level 1, Level 2, Level 3, Level 4). The telephone will dial the pre-programmed number.

2.3 After you hear the voice prompt: "good-bye", hang-up the receiver or press the "SPEAKER" button.

2.3.1 IF you hear a voice prompt other than "good-bye", THEN hang-up the receiver or press the "SPEAKER" button, wait five (5) seconds, and repeat Steps 2.1 through 2.3.

2.3.2 IF the "good-bye" voice prompt is not heard after the 2 rnd attempt, THEN the automated call out system was NOT successfully activated. DIRECT the ECC Communicator to implement Exhibit 7, "Back-Up Communications,Section II - Equipment Failure Alternatives", AND PROCEED directly to Step 3.0 of this exhibit.

5

TMI Emergency Plan Imolementina Procedure Title Emergency Notifications and Call Outs EXHIBIT I Number

  • 1-.

EPIP-TMI-.03 Revision NO 37 Page 2 of 5 IF the "good-bye" voice prompt was heard, THEN complete the following table. After completing the table, PROCEED directly to Step 3.0 of this exhibit.

TIME ACTIVATION ACTUAL EVENT or INITIATED APPLICABLE DRILL SCENARIO #

(24-Hour Time)

LEVEL (Circle)

(NA If Not Applicable)

Level 1 401 / 405 Level 2 402 / 406 Level 3 403 / 407 Level 4 404 3.0 Perform 15 Minute Notifications.

3.1 Confirm Dial tone on the Notification Line.

3.2 Place Toggle Switch up to OVERRIDE.

3.3 Dial 91.

3.4 When the calling tone is heard, place Toggle Switch down to NORMAL.

3.5 As the agencies answer, state, "This is Three Mile Island Nuclear Station. Stand by for an emergency message." (State once and proceed immediately to the next step.)

3.5.1 Log the time.

Ask if each agency is on the line.

[PEMA, are you on the line? Dauphin County?, etc.]

PEMA (check when on line)

Dauphin County Cumberland County Lancaster County Lebanon County York County 6

2.4 3.6

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No.

Emergency Notifications and Call Outs 37 EXHIBIT 1 Page 3 of 5 3.7 If one or more agencies do not answer promptly, THEN instruct another qualified ECC Communicator if available, to perform a parallel notification to the missing agency using the Off Site Notification Auto Dialer or Exhibit 7 as necessary.

3.7.1 If necessary to perform parallel notifications, THEN log person contacted for the correct county in Step 3.10.

3.8 State, "Please stay on the line after the following message to provide a name or dispatcher number and to confirm receipt."

3.9 Read Emergency Report Form, Part 1.

Time notification completed IF escalation(s) of the event status has occurred; THEN read the Emergency Report Form, Part 1 for each escalation.

3.10 Request receipt confirmation.

"PEMA, name or dispatcher number?"

"Dauphin County?"

"Cumberland County?"

"Lancaster County?"

"Lebanon County?"

"York County?"

3.11 Flash the hook switch until a dial tone is heard THEN hang up.

4.0 If not already notified in parallel by another ECC Communicator, THEN Notify remaining agencies that did not receive the information by using the Off Site Notification Auto Dialer or Exhibit 7, as necessary.

Read the Report Form (should be Report Form, Part 1) for each event level declared.

0 Log receipt confirmation by recording name/dispatcher number and time notified in appropriate blank in Step 3.10.

7

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT I Page 4 of 5 5.0 If the escalation(s) has occurred and notification to the State and Counties for higher events were made in Step 3.9 and/or Step 4.0, THEN perform the following:

1.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate exhibit(s) in Steps 3.9 and 3.10.

2.

Perform Step 2 for the highest event reported.

3.

GO TO Step 6 of the highest event exhibit and continue on. (Substeps 4 and 5 may be performed in parallel with other steps).

4.

When time permits, THEN N/A steps in lower events that were performed in the highest event exhibit.

5.

When time permits, THEN N/A steps in Step 3 of the higher exhibit(s) that were performed during this exhibit.

6.0 If I&C Technicians were performing the previous steps, THEN the I&C Technicians are to provide a turn over of this exhibit to a qualified ECC Communications Coordinator (CRO or IREO Communications Coordinator).

7.0 When an ECC Communicator is available, THEN direct an ECC Communicator to perform Exhibit 9 of this procedure and provide Part 2 of the Emergency Report Form to him/her.

8.0 Pin on the ECC Communications Coordinator pin.

9.0 NRC Notification using the Emergency Notification System (ENS) 9.1 Dial the twelve digit number attached on the ENS telephone.

9.2 Read the Emergency Report Form, Part 1 for each event level declared.

9.3 Record the person contacted.

Name Time 8

TMI Emergency Plan ImDlementina Procedure Title Emeraencv Notifications and Call Outs EXHIBIT 1 Number EPIP-TMI-.03 Revision No 37 Page 5 of 5 Maintain continuous communications unless directed otherwise by the NRC Duty Officer.

If continuous communications are terminated by the NRC Duty Officer, THEN record the name of the individual directing termination.

Name 9

9.4

Title Emergency Notifications and Call Outs TMI Emergency Plan Implementinq Procedure

  • 1 Number EPIP-TMI-.03 Revision No 37 EXHIBIT 2 Page 1 of 5 Obtain an Emergency Report Form Part 1 and 2 from the Emergency Director or Shift Manager's computer printer.

2.0 Activate the automated call out system.

IF a Level 2 or Level 3 activation was performed at the Unusual Event classification, THEN "NA" Steps 2.1 through 2.4 of this exhibit and PROCEED IMMEDIATELY to Step 3.0 of this exhibit.

Lift the EP Pager Call Out Phone receiver or press the "SPEAKER" button.

2.2.1 Press the applicable "LEVEL" button (designated on Part 1 of the Emergency Report Form, for the Alert classification, the options are Level 2 and Level 3). The telephone will dial the pre-programmed number.

2.3 After you hear the voice prompt: "good-bye", hang-up the receiver or press the "SPEAKER" button.

IF you hear a voice prompt other than "good-bye", THEN hang-up the receiver or press the "SPEAKER" button, wait five (5) seconds, and repeat Steps 2.2 and 2.3.

10 1.0 ALERT CHECKLIST NOTE Do not allow problems encountered in Step 2.0 to interfere with completion of the 15 minute off site notifications per Step 3.0. Steps 2 through 4 may be performed in parallel if manpower is available.

2.1 2.2 2.3.1

Title

+

Title

  • -Emerqencv Notifications and Call Outs TMI Emergency Plan Implementinq Procedure Number EPIP-TMI-.03 Revision No 37 EXHIBIT 2 Page 2 of 5 2.4 2.3.2 IF the "good-bye" voice prompt is not heard after the 2nd attempt, THEN the automated call out system was NOT successfully activated. DIRECT the ECC Communicator to implement Exhibit 7, "Back-Up Communications,Section II - Equipment Failure Alternatives", AND PROCEED directly to Step 3.0 of this exhibit.

IF the "good-bye" voice prompt was heard, THEN complete the following table. After completing the table, PROCEED directly to Step 3.0 of this exhibit.

ACTUAL EVENT or TIME ACTIVATION DRILL/EXERCISE INITIATED APPLICABLE SCENARIO #

(24-Hour Time)

LEVEL (Circle)

(NA If Not Applicable)

Level 2 402 / 406 Level 3 403 / 407 3.0 Perform 15 Minute Notifications.

3.1 Confirm Dial tone on the Notification Line.

3.2 Place Toggle Switch up to OVERRIDE.

3.3 Dial 91.

3.4 WHEN the calling tone is heard, place Toggle Switch down to NORMAL.

3.5 As the agencies answer, state, "This is Three Mile Island Nuclear Station.

Stand by for an emergency message."

(State once and proceed immediately to the next step.)

0 Log the time:

11

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 2 Page 3 of 5 3.6 Ask if each agency is on the line.

[PEMA, are you on the line? Dauphin County?, etc.]

PEMA (check when on line)

Dauphin County Cumberland County Lancaster County Lebanon County York County

,3.7 If one or more agencies do not answer promptly, THEN instruct another qualified ECC Communicator if available, to perform a parallel notification to the missing agency using the Off Site Notification Auto Dialer or Exhibit 7 as necessary.

If necessary to perform parallel notifications, THEN log person contacted for the correct county in step 3.10.

3.8 State, "Please stay on the line after the following message to provide a name or dispatcher number and to confirm receipt."

3.9 Read Emergency Report Form, Part 1.

Time notification completed IF escalation(s) of the event status has occurred, THEN read the Emergency Report Form, Part 1 for each escalation.

3.10 Request receipt confirmation.

"PEMA, name or dispatcher number?"

"Dauphin County?"

"Cumberland County?"

"Lancaster County?"

"Lebanon County?"

"York County?"

3.11 Flash the hook switch until a dial tone is heard, THEN hang up.

12

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 2 Page 4 of 5 4.0 If not already notified in parallel by another ECC Communicator, THEN Notify remaining agencies that did not receive the information by using the Off Site Notification Auto Dialer or Exhibit 7 as necessary.

Read the Emergency Report Form for each event level declared.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate blank in Step 3.10.

5.0 IF an escalation(s) has occurred and notification to the State and Counties for the higher event(s) were made in Step 3.9 and/or Step 4.0, THEN perform the following:

1.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate exhibit(s), in Steps 3.9 and 3.10.

2.

Perform Step 2 for the highest event reported.

_3.

GO TO Step 6 of the highest event exhibit and continue on. (Substeps 4 and 5 may be performed in parallel with other steps).

4.

When time permits, THEN N/A steps in lower events that were performed in the highest event exhibit.

5.

WHEN time permits, THEN N/A steps in Step 3 of the higher exhibit(s) that were performed during this exhibit.

6.0 If I&C Technicians were performing the previous steps, I&C Technicians are to provide a turn over of this exhibit to a qualified ECC Communications Coordinator (CRO or IREO Communications Coordinator).

7.0 If not already performed, THEN direct the ECC Communicator when available, to perform Exhibit 9 of this procedure and provide Part 2 of the Emergency Report Form to him/her.

8.0 Pin on the ECC Communications Coordinator pin.

13

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 2 Page 5 of 5 9.0 Verify activation of ERDS (Emergency Response Data System) by the Shift Engineer.

9.1 Provide Exhibit 6 to the Shift Engineer.

9.2 If ERDS cannot be activated, THEN complete Exhibit 8, Emergency Status Log before calling the NRC.

10.0 NRC Notification using the Emergency Notification System (ENS) 10.1 IF not already on line THEN Dial the twelve digit number attached on the ENS telephone.

10.2 Read the Emergency Report Form, Part 1 for each event level declared.

10.3 Record the person contacted.

Name Time 10.4 Maintain continuous communications unless directed otherwise by the NRC Duty Officer.

If continuous communications are terminated by the NRC Duty Officer, THEN record the name of the individual directing termination.

Name 14

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 3 Page 1 of 5 SITE AREA EMERGENCY CHECKLIST 1.0 Obtain an Emergency Report Form Part 1 and 2 from the Emergency Director or Shift Manager's computer printer.

NOTE Do not allow problems encountered in Step 2.0 to interfere with completion of the 15 minute off site notifications per Step 3.0. Steps 2 through 4 may be performed in parallel if manpower is available.

2.0 Activate the automated call out system.

NOTE See the completed "Applicable Level" information in Step 2.4 of Exhibits 1 and 2.

2.1 IF a Level 3 activation was performed at the Unusual Event or Alert classifications, THEN "NA" Steps 2.1 through 2.4 of this exhibit and PROCEED IMMEDIATELY to Step 3.0 of this exhibit.

2.2 Lift the EP Pager Call Out Phone receiver or press the "SPEAKER" button.

2.2.1 Press the applicable "LEVEL" button (designated on Part 1 of the Emergency Report Form, for the Site Area Emergency classification the only choice is Level 3). The telephone will dial the pre-programmed number.

2.3 After you hear the voice prompt: "good-bye", hang-up the receiver or press the "SPEAKER" button.

2.3.1 IF you hear a voice prompt other than "good-bye", THEN hang-up the receiver or press the "SPEAKER" button, wait five (5) seconds, and repeat Steps 2.2 and 2.3.

15

Title Emerqencv Notifications and Call Outs TMI Emergency Plan Implementing Procedure Number EPIP-TMI-.03 Revision No.

37 EXHIBIT 3 Page 2 of 5 2.4 2.3.2 IF the "good-bye" voice prompt is not heard after the 2 nd attempt, THEN the automated call out system was NOT successfully activated. DIRECT the ECC Communicator to implement Exhibit 7, "Back-Up Communications,Section II - Equipment Failure Alternatives", AND PROCEED directly to Step 3.0 of this exhibit.

IF the "good-bye" voice prompt was heard, THEN complete the following table. After completing the table, PROCEED directly to Step 3.0 of this exhibit.

ACTUAL EVENT or TIME ACTIVATION DRILL/EXERCISE INITIATED APPLICABLE SCENARIO #

(24-Hour Time)

LEVEL (Circle)

(NA If Not Applicable)

Level 3 403 / 407 3.0 Perform 15 Minute Notifications.

3.1 Confirm Dial tone on the Notification Line.

3.2 Place Toggle Switch up to OVERRIDE.

3.3 Dial 91.

3.4 When the calling tone is heard, place Toggle Switch down to NORMAL.

3.5 As the agencies answer, state, "This is Three Mile Island Nuclear Station. Stand by for an emergency message."

(State once and proceed immediately to the next step.)

3.5.1 Log the time:

16

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 3 Page 3 of 5 3.6 Ask if each agency is on the line.

[PEMA, are you on the line? Dauphin County?, etc.]

PEMA (check when on line)

Dauphin County Cumberland County Lancaster County Lebanon County York County 3.7 If one or more agencies do not answer promptly, THEN instruct another qualified ECC Communicator if available, to perform a parallel notification to the missing agency using the Off Site Notification Auto Dialer.

If necessary to perform parallel notifications, log person contacted for the correct county in Step 3.10.

L____

3.8 State, "Please stay on the line after the following message to provide a name or dispatcher number and to confirm receipt."

3.9 Read Emergency Report Form, Part 1.

Time notification completed IF escalation(s) of the event status has occurred, THEN read the Emergency Report Form, Part 1 for each escalation.

3.10 Request receipt confirmation.

"PEMA, name or dispatcher number?"

"Dauphin County?"

"Cumberland County?"

"Lancaster County?"

"Lebanon County?"

"York County?"

3.11 Flash the hook switch until a dial tone is heard THEN hang up.

17

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 3 Page 4 of 5 4.0 If not already notified in parallel by another ECC Communicator THEN Notify remaining agencies that did not receive the information by using the Off Site Notification Auto Dialer or Exhibit 7, as necessary.

Read the Emergency Report Form for each event level declared.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate blank in Step 3.10.

5.0 If an escalation(s) has occurred and notification to the Sate and Counties for the Higher Event(s) were made in Step 3.9 and/or Step 4.0, THEN perform the following:

1.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate Exhibit(s), in Steps 3.9 and 3.10.

2.

Perform Step 2 for the highest Event reported.

_3.

GO TO Step 6 of the highest Event Exhibit and continue on. (Substeps 4 and 5 may be performed in parallel with other steps).

4.

WHEN time permits, THEN N/A steps in lower Events that were performed in the highest Event Exhibit.

5.

WHEN time permits, THEN N/A steps in Step 3 of the higher Exhibit that were performed during this exhibit.

6.0 If I&C Technicians were performing the previous steps, THEN I&C Technicians are to provide a turn over of this exhibit to a qualified ECC Communications Coordinator (CRO or IREO Communications Coordinator).

7.0 If not already performed, THEN direct an ECC Communicator when available, to perform Exhibit 9 of this procedure and provide Part 2 of the Emergency Report Form to him/her.

8.0 Pin on the ECC Communications Coordinator pin.

18

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 3 Page 5 of 5

-9.0 Verify activation of ERDS (Emergency Response Data System) by the Shift Engineer.

9.1 Provide Exhibit 6 to the Shift Engineer.

9.2 If ERDS cannot be activated, THEN complete Exhibit 8, Emergency Status Log before calling the NRC.

10.0 NRC Notification using the Emergency Notification System (ENS) 10.1 If not already on line, Then Dial the twelve digit number attached on the ENS telephone.

10.2 Read the Emergency Report Form, Part 1 for each event level declared.

10.3 Record the person contacted.

Name Time 10.4 Maintain continuous communications unless directed otherwise by the NRC Duty Officer.

If continuous communications are terminated by the NRC Duty Officer, record the name of the individual directing termination.

Name 19

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 4 Page 1 of 5 GENERAL EMERGENCY CHECKLIST 1.0 Obtain an Emergency Report Form Part 1 and 2 from the Emergency Director or Shift Manager's computer printer.

NOTE Do not allow problems encountered in Step 2.0 to interfere with completion of the 15 minute off site notifications per' Step 3.0. Steps 2 through 4 may be performed in parallel if manpower is available.

2.0 Activate the automated call out system.

NOTE See the completed "Applicable Level" information in Step 2.4 of Exhibits 1, 2 and 3.

2.1 IF a Level 3 activation was performed at the Unusual Event, Alert, or Site Area Emergency classifications, THEN "NA" Steps 2.1 through 2.4 of this exhibit and PROCEED IMMEDIATELY to Step 3.0 of this exhibit.

2.2 Lift the EP Pager Call Out Phone receiver or press the "SPEAKER" button.

2.2.1 Press the applicable "LEVEL" button (designated on Part 1 of the Emergency Report Form, for the General Emergency classification the only choice is Level 3). The telephone will dial the pre-programmed number.

2.3 After you hear the voice prompt: "good-bye", hang-up the receiver or press the "SPEAKER" button.

2.3.1 IF you hear a voice prompt other than "good-bye", THEN hang-up the receiver or press the "SPEAKER" button, wait five (5) seconds, and repeat Steps 2.2 and 2.3.

20

TMI Emergency Plan Implementing Procedure Title E*merqencv Notifications and Call Outs EXHIBIT 4 Number EPIP-TMI-.03 Revision No 37 Page 2 of 5 2.3.2 IF the "good-bye" voice prompt is not heard after the 2 nd attempt, THEN the automated call out system was NOT successfully activated. DIRECT the ECC Communicator to implement Exhibit 7, "Back-Up Communications,Section II - Equipment Failure Alternatives", AND PROCEED directly to Step 3.0 of this exhibit.

IF the "good-bye" voice prompt was heard, THEN complete the following table. After completing the table, PROCEED directly to Step 3.0 of this exhibit.

ACTUAL EVENT or TIME ACTIVATION DRILLIEXERCISE INITIATED APPLICABLE SCENARIO #

(24-Hour Time)

LEVEL (Circle)

(NA If Not Applicable)

Level 3 403 / 407 3.0 Perform 15 Minute Notifications.

Confirm Dial tone on the Notification Line.

Place Toggle Switch up to OVERRIDE.

Dial 91.

When the calling tone is heard, place Toggle Switch down to NORMAL.

As the agencies answer, state, "This is Three Mile Island Nuclear Station. Stand by for an emergency message."

(State,once and proceed immediately to the next step.)

0 Log the time:

21 2.4 3.1 3.2 3.3 3.4 3.5 I

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 4 Page 3 of 5 3.6 Ask if each agency is on the line.

[PEMA, are you on the line? Dauphin County?, etc.]

PEMA (check when on line)

Dauphin County Cumberland County Lancaster County Lebanon County York County 3.7 If one or more agencies do not answer promptly, THEN instruct another qualified ECC Communicator if available, to perform a parallel notification to the missing agency using the Off Site Notification Auto Dialer.

If necessary to perform parallel notifications, THEN log person contacted for the correct county in Step 3.10.

State, "Please stay on the line after the following message to provide a name or dispatcher number and to confirm receipt."

3.9 Read Emergency Report Form, Part 1.

Time notification completed 3.10 Request receipt confirmation.

"PEMA, name or dispatcher number?"

"Dauphin County?"

"Cumberland County?"

"Lancaster County?"

"Lebanon County?"

"York County?"

3.11 Flash the hook switch until a dial tone is heard, THEN hang up.

22

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 4 Page 4 of 5 4.0 If not already notified in parallel by another ECC Communicator THEN Notify remaining agencies that did not receive the information by using the Off Site Notification Auto Dialer or Exhibit 7, as necessary.

Read the Emergency Report Form for each event level declared.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate blank in Step 3.10.

5.0 If an escalation has occurred and the Emergency Report Form, Part 1 (for the GENERAL EMERGENCY) was read during Notification to the State and Counties using a lower Exhibit, THEN perform the following:

1.

Log receipt confirmation by recording name/dispatcher number and time notified in appropriate Exhibit(s), in Steps 3.9 and 3.10.

2.

Perform Step 2 for this Event.

_3.

GO TO Step 6 of this Event Exhibit and continue on. (Substeps 4 and 5 may be performed in parallel with other steps).

4.

WHEN time permits, THEN N/A steps in lower Events that were performed in the highest Event Exhibit.

5.

WHEN time permits, THEN N/A steps in Step 3 that were performed during the reclassification.

6.0 If I&C Technicians were performing the previous steps, THEN I&C Technicians are to provide a turn over of this exhibit to a qualified ECC Communications Coordinator (CRO or IREO Communications Coordinator).

7.0 If not already performed, THEN direct an ECC Communicator when available, to perform Exhibit 9 of this procedure and provide Part 2 of the Emergency Report Form to him/her.

8.0 Pin on the ECC Communications Coordinator pin.

23

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 4 Page 5 of 5 9.0 Verify activation of ERDS (Emergency Response Data System) by the Shift Engineer.

9.1 Provide Exhibit 6 to the Shift Engineer.

9.2 If ERDS cannot be activated, THEN complete Exhibit 8, Emergency Status Log before calling the NRC.

10.0 NRC Notification using the Emergency Notification System (ENS) 10.1 If not already on line THEN Dial the twelve digit number attached on the ENS telephone.

10.2 Read the Emergency Report Form, Part 1 for each event level declared.

10.3 Record the person contacted.

Name Time 10.4 Maintain continuous communications unless directed otherwise by the NRC Duty Officer.

If continuous communications are terminated by the NRC Duty Officer, THEN record the name of the individual directing termination.

Name 24

TMI Emergency Plan Implementing Procedure Title Emerqencv Notifications and Call Outs EXHIBIT 5 Number EPIP-TMI-.03 Revision No 37 Page 1 of 2 CLOSEOUT NOTIFICATION CHECKLIST 1.0 Obtain an Emergency Report Form from Emergency Director or Shift Manager's computer printer.

2.0 Perform Off Site Notifications.

2.1 Confirm Dial tone on the Notification Line.

2.2 Place Toggle Switch up to OVERRIDE.

2.3 Dial 91.

2.4 When the calling tone is heard, place Toggle Switch down to NORMAL.

2.5 As the agencies answer, state, "This is Three Mile Island Nuclear Station. Stand by for an emergency message."

(State once and proceed immediately to the next step.)

2.6 Ask if each agency is on the line.

[PEMA, are you on the line? Dauphin County?, etc.]

PEMA Dauphin County Cumberland County Lancaster County Lebanon County York County (check when on line)

State, "Please stay on the line after the following message to provide a name or dispatcher number and to confirm receipt."

Read Emergency Report Form.

Time notification completed 25 2.7 2.8

TMI Emergency Plan Implementing Procedure Title Emergency Notifications and Call Outs Number EPIP-TMI-.03 Revision No 37 EXHIBIT 5 Page 2 of 2 2.9 Request receipt confirmation.

"PEMA, name or dispatcher number?"

"Dauphin County?"

"Cumberland County?"

"Lancaster County?"

"Lebanon County?"

"York County?"

2.10 Flash the hook switch until a dial tone is heard, THEN hang up.

3.0 If all agencies did not receive the information, THEN Notify the remaining agencies.

0 4.0 NRC 4.1 4.2 4.3 Log receipt confirmation by recording name/dispatcher number and time notified in appropriate blank in Step 2.9.

Notification using the Emergency Notification System (ENS)

If not already on line then Dial the twelve digit number attached on the ENS telephone.

Read the Emergency Report Form.

Record the person contacted.

Name Time 26

TMI Emergency Plan Implementing Procedure Title Emerqencv Notifications and Call Outs EXHIBIT 6 Number EPIP-TMI-.03 Revision No 37 Page 1 of 2 EMERGENCY RESPONSE DATA SYSTEM ACTIVATION NOTE Perform the following steps at Control Room CRT 3 or CRT 4. If unavailable, use the TSC CRT.

1.0 Select "ERDS". The Emergency Response Data System - page is displayed.

2.0 Select "Initiate". The Emergency Response Data System - Parameter Display page shows ERDS status active and Link Status as "Dialing Modem" 3.0 Confirm link established by the following indication displayed at the bottom of the Emergency Response Data System - Parameter Display page:

Link Status:

ERDS Status:

Link Active Active 4.0 If the link cannot be established, THEN request the ECC Communications Coordinator to pursue resolution of the problem.

5.0 WHEN required to terminate ERDS, THEN perform the following:

5.1 5.2 Select "ERDS".

Select "Terminate".

27 NOTE Activation of ERDS is performed by the Shift Technical Advisor. The ECC Communications Coordinator confirms establishment of the link.

TMI Emergency Plan Implementing Procedure Emergency Notifications and Call Outs EXHIBIT 6 Number EPIP-TMI-.03 Revision No 37 Page 2 of 2 PROBLEM RESOLUTION

1.

Failure to complete the link will be indicated by the following display at the bottom of the Emergency Response Data System - Parameter Display page:

Link Status:

ERDS Status:

NRC Link Denied or Phone Line Lost, Phone Busy, Phone No Answer Active

.2.

Contact the NRC using the ENS Line or dial telephone to ensure a line is available and they are prepared to receive ERDS data.

3.

The software should automatically re-establish the link in the event of a problem, but manual intervention may be required.

4.

If manual intervention is required to re-establish the link.

4.1 Select "ERDS".

4.2 Select "Terminate".

4.3 Select "Reconnect".

5.

To obtain assistance with ERDS problems not resolved by the previous actions, contact the computer support individual listed on the Initial Response Emergency Organization Duty Roster.

28 Title NOTE If NRC terminates the link, the statuses will be:

Link Status:

Not Connected ERDS status:

Inactive

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 7 Page 1 of 7 Back Up Communications SECTION I - ADDITIONAL TELEPHONE NUMBERSIALTERNATE COMMUNICATIONS PATHWAYS Pennsylvania Emergency Management Agency A.

Lines specified in Exhibits 1, 2, 3, 4, & 5 N otification Line................

37 B

Com m ercial telephone lines...............................................................................................

9-651-2001 C.

PEMARS Radio Link D.

Message relay through a risk county.

Risk Counties A.

Lines specified in the Exhibits 1, 2, 3, 4, & 5.

Notification Line Dauphin County.....................................................................

38 York County.............................................................................

30 Lancaster County.....................................................................

34 Cumberland County...............................

35 Lebanon County................................................................... 39 B.

Commercial telephone lines Dauphin C ounty......................................................................

9-911

...................................................................................... 9-558-6900 S..................................................................................

9-558-6800 York County....................................................................

9-854-5571

........................................................................................ 9-840-7555

ý.

.................................. 9-1-800-427-8347 Lancaster County............................................................

9-664-1200

.................................................................................. 9-664-1190 Cumberland County........................................................

9-238-9676

........................................................................................ 9-243-4 12 1 9-532-8878 Lebanon County..............................................................

9-272-2025

..................................................................................... 9-272-762 1

...................................................................................... 9-272-2054 C

PEMARS Radio Link D.

Message relay through PEMA E.

Message relay through neighboring risk county.

29

TMI Emergency Plan Implementing Procedure Title Emerqencv Notifications and Call Outs EXHIBIT 7 Number EPIP-TMI-.03 Revision No 37 Page 2 of 7 Nuclear Regulatory Commission A.

NRC Dedicated Telephone Circuits Emergency Notification System (ENS)

Health Physics Network (HPN)

Protective Measures Counterpart Link (PMCL)

Reactor Safety Counterpart Link (RSCL)

Management Counterpart Link (MCL)

Local Area Network (LAN)

Prim ary Num ber......................................................................................

9-1-800-532-3469 Back up Num ber 1..................................................................................

9-1-800-449-3694 B

Commercial telephone lines Primary Number.........

............................... 9-1-800-532-3469 Back up Number 1.............................................

9-1-800-449-3694 C.

Message relay through PEMA or Risk County.

30 NOTE When using the Emergency Notification System (ENS), Health Physics Network (HPN), Protective Measures Counterpart Link (PMCL), Reactor Safety Counterpart Link (RSCL), Management Counterpart Link (MCL),

or Local Area Network (LAN) telephones, dial only the ten digit number.

Do not dial "9" or "1" before dialing the numbers listed when using these NRC telephones.

NOTE

1. Although local telephone service may be affected, the microwave/fiber optics telephone system to remote facilities may be functional and allow a message relay.
2. If all telephone service to TMI is lost, a relay to the EOF over the Environmental Assessment Radio could be used for communications. Telephone service at the EOF may still be functional allowing notifications to be made by the EOF staff.

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No

/

Emergency Notifications and Call Outs 37 EXHIBIT 7 Page 3 of 7 SECTION II - EQUIPMENT FAILURE ALTERNATIVES NOTE All communications equipment failures should be reported to the ECC Communications Coordinator for resolution.

Meridian Telephone System Failure A.

Use available telephones with a 944 prefix. (e g., EP Pager Call Out Phone) These telephones are connected directly to the Middletown Central Office and are independent of the Meridian System.

The Automated Call Out System DID NOT Activate After Utilizing The Designated Buttons On The EP Pager Call Out Phone As Specified In Step 2.2 of Exhibits 1, 2, 3, or 4 (the system did not generate an initial "RESPONSE STATUS REPORT" and transmit it to the ECC facsimile (fax) machine as expected) THEN perform a manual activation of the automated call out system as follows:

A.

Obtain the automated call out system telephone number from the Shift Manager's Office safe or in the Control Room from the Control Room Supervisor desk cabinet.

B.

Utilizing any functional touch-tone telephone, manually dial the automated call out system activation number that was determined in step A C.

After hearing the voice prompt: "This is the remote activation module. Please enter your scenario activation password followed by the pound (#) sign", THEN promptly proceed as follows:

1.

Level 1 - Utilize the telephone keypad to enter "4 0 1 #" (ACTUAL EVENT) or "4 0 5 #" (Level 1 DRILL), wait approximately five (5) seconds, and enter "4 0 1 # 3 #" (ACTUAL EVENT).r "4 0 5 # 3 #" (Level I DRILL) and hang-up the telephone receiver.

2.

Level 2 - Utilize the telephone keypad to ENTER "4 0 2 #" (ACTUAL EVENT) or "4 0 6 #" (Level 2 DRILL), wait approximately five (5) seconds, and enter "4 0 2 # 3 #" (ACTUAL EVENT) or "4 0 6 # 3 #" (Level 2 DRILL) and hang-up the telephone receiver.

3.

Level 3 - Utilize the telephone keypad to ENTER "4 0 3 #" (ACTUAL EVENT) or "4 0 7 #" (Level 3 DRILL), wait approximately five (5) seconds, and enter "4 0 3 # 3 #" (ACTUAL EVENT) or "4 0 7 # 3 #" (Level 3 DRILL) and hang-up the telephone receiver.

4.

Level 4 - Utilize the telephone keypad to ENTER "4 0 4 #" (Level 4 ACTUAL EVENT or DRILL),

wait approximately five (5) seconds, and enter "4 0 4 # 3 #" (Level 4 ACTUAL EVENT or DRILL) and hang-up the telephone receiver.

31

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No.

Emergency Notifications and Call Outs 37 EXHIBIT 7 Page 4 of 7 The Automated Call Out System DID NOT Activate After Utilizing the EP Pager Call Out Phone AND The Manual Activation Process Contained In This Exhibit (the system DID NOT generate an initial "RESPONSE STATUS REPORT" and transmit it to the ECC facsimile (fax) machine as expected, after either attempt), THEN utilize the off-site redundant back-up system as follows:

A.

Obtain the off-site redundant back-up system telephone number and company ID number from the Shift Manager's Office safe or in the Control Room from the Control Room Supervi~or desk cabinet.

B.

Utilizing any functional touch-tone telephone, pick-up the receiver and manually dial the off-site redundant back-up system telephone number that was determined in step A.

C.

After hearing the voice prompt: "This is the DCC service bureau. Please enter your company ID number followed by the pound (#) sign", THEN promptly enter the company ID number that was determined in Step A followed by the pound (#) sign.

D.

After hearing the voice prompt. "Please enter your scenano activation password followed by the pound (#)

sign", THEN promptly proceed as follows:

1.

Level 1 - Utilize the telephone keypad to enter "4 0 1 #" (ACTUAL EVENT) or "4 0 5 #" (Level 1 DRILL), wait approximately five (5) seconds, and enter "4 0 1 # 3 #" (ACTUAL EVENT) or "4 0 5 # 3 #" (Level 1 DRILL) and hang-up the telephone receiver.

2 Level 2 - Utilize the telephone keypad to ENTER "4 0 2 #" (ACTUAL EVENT) or "4 0 6 #" (Level 2 DRILL), wait approximately five (5) seconds, and enter "4 0 2 # 3 #" (ACTUAL EVENT) or "4 0 6 # 3 #" (Level 2 DRILL) and hang-up the telephone receiver.

3.

Level 3 - Utilize the telephone keypad to ENTER "4 0 3 #" (ACTUAL EVENT) or "4 0 7 #" (Level 3 DRILL), wait approximately five (5) seconds, and enter "4 0 3 # 3 #" (ACTUAL EVENT) or"4 0 7 # 3 #" (Level 3 DRILL) and hang-up the telephone receiver.

4.

Level 4 - Utilize the telephone keypad to ENTER "4 0 4 #" (Level 4 ACTUAL EVENT or DRILL),

wait approximately five (5) seconds, and enter "4 0 4 # 3 #" (Level 4 ACTUAL EVENT or DRILL) and hang-up the telephone receiver.

32

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 7 Page 5 of 7 The Automated Call Out Systems DID NOT Activate After Utilizing the EP Pager Call Out Phone AND The Manual Activation Process Contained In This Exhibit AND The Offsite Redundant Back Up System (the systems DID NOT generated an initial "RESPONSE STATUS REPORT" and transmit it to the ECC facsimile (fax) machine, as expected), THEN utilize any functional touch-tone telephone to perform a manual activation of the group pagers AND utilize the EP Pager Call Back Line (948-8801) as follows:

1.

Obtain the group page activation number and password numbers from the Shift Manager's Office safe or in the Control Room from the Control Room Supervisor desk cabinet.

2.

Using any touch-tone telephone (i.e., non-rotary dial telephone), dial the group page activation number.

3.

When the voice prompt "Please enter your caller password" is heard, promptly proceed as follows based on the level of response indicated on the Emergency Report Form.

a.

Level I Enter password from Step 1 followed by Dial "948*8801*1#" to notify the Public Information Duty representative. When the voice prompt "Thank You" or the page tones are heard, THEN wait 10 seconds and then hang up."

b.

Level 2 Enter password from Step 1 followed by Dial "948*8801*2#" to activate the Initial Response Emergency Organization, EACC and the Public Information Duty Representative When the voice prompt "Thank You" or the page tones are heard, THEN wait 10 seconds and then hang up

c.

Level 3 Enter password from Step 1 followed by Dialing "948*8801*3#" to activate the Emergency Support Organization, Initial Response Emergency Organization, the EACC, and the Public Information Duty Representative.

When the voice prompt "Thank You" or the page tones are heard, THEN wait 10 seconds and then hang up.

d.

Level 4 Enter password from Step A followed by Dialing "948*8801*4#" to staff the Emergency Support Organization, Initial Response Emergency Organization, the EACC, and the Public Information Duty Representative On-Call section. When the voice prompt 'Thank You" or the page tones are heard, wait 10 seconds and hang up.

After individuals have had time to respond to the page, use any Meridian telephone to dial "8424".

(The voice prompt "Meridian mail. Mail box?" will be heard).

4.

Press the star (*) key.

5.

Enter mailbox number you wish to retrieve messages from:

9901 - On Duty 9902 - Extra IREO 9903 - Extra ESO

6.

Dial "CALL OUT#" (or "2255688#"). Press 1 to check unheard messages.

7.

At this point the steps of Exhibit 9, starting at Step 7.8.10, may be followed.

33

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No.

Emergency Notifications and Call Outs 37 EXHIBIT 7 Page 6 of 7

8.

If the group page activation was unsuccessful (no messages were posted on the voice mailboxes),

THEN utilize the "Backup EP Group Pager Number" and "Password" obtained in Step 1 and the instructions contained in Steps 2, 3, 4, 5, and 6 above to perform a second attempt.

9.

If the group page activation was successful (messages were posted on the voice mailboxes), THEN the steps of Exhibit 9, starting at Step 6.8.12, may be followed.

The Group Pagers Do Not Activate After Two (2) Attempts, THEN perform a manual call out of the ERO utilizing the EP Pager Call Back Line (948-8801) as follows:

1.

Contact the duty Emergency Preparedness Representative (Position 504 on the Emergency Support Organization Duty Roster) using the telephone numbers provided in the phone list kept with the duty rosters and request assistance with call outs.

2.

In coordination with the Emergency Preparedness Rep., call personnel individually at the numbers provided in the Duty Roster and telephone list.

2.1 Call the office number during normal work hours 2.2 Call the home number after normal work hours 2.3 Attempt to individually page personnel:

a.

Dial the pager number shown on the Duty Roster

b.

Dial one of the following numbers as indicated on the Emergency Report Form

1.

Level 1 dial - "948*8801*1#"

2.

Level 2 dial - "948*8801*2#"

3.

Level 3 dial - "948*8801*3#"

4.

Level 4 dial - "948*8801*4#

c.

After hearing the voice prompt "Thank you" or when the page tones are heard, THEN wait 10 seconds and then Hang up.

2.4 Repeat steps 2.1 through 2.3 for each individual required to respond.

If It Becomes Necessary To Perform Call-Outs From A Remote Location, THEN perform a manual activation of the automated call out system by following the instructions contained in the section of this Exhibit entitled "The Automated Call Out System Does Not Activate After Utilizing The Designated Buttons On The EP Pager Call Out Phone As Specified In Step 2.2 of Exhibits 1, 2, 3, or 4".

1.

If the successful activation of the automated call out system from a remote location can not be confirmed via the transmission of "RESPONSE STATUS REPORTS" to the ECC or EOF, THEN perform a manual activation of the group pagers AND utilize the EP Pager Call Back Line (948-8801) by following the instructions contained in the section of this Exhibit entitled "The Automated Call Out Systems DID NOT Activate After Utilizinq The EP Pager Call Out Phone And The Manual Activation Process Contained In This Exhibit And The Offsite Redundant Back Up System".

34

TMI Emergency Plan Implementing Procedure Title Emergency Notifications and Call Outs EXHIBIT 7 Number EPIP-TMI-.03 Revision No 37 Page 7 of 7 Middletown Switching System (Central Office) Failure

1.

Bypass the Middletown Central Office by using the GPU fiber optics system Using any Shift Manager's Office, Control Room, or TSC telephone, dial 2911-9-1-Area Code (if other than 610)-telephone number.

2.

Group pager activation may be completed by obtaining the number from the Shift Manager or Control Room Supervisor and dialing 2911-9-1-800-number from any Shift Manager's Office, Control Room, or TSC telephone.

Harrisburg Central Office Failure

1.

Dial local calls to telephone numbers with 944,948, and 367 prefixes in the normal manner.

/

2.

With the exception of Harrisburg exchanges, complete all other calls using the GPU fiber optics system.

Using any Shift Manager's Office, Control Room, or TSC telephone, dial 2911-9-1-Area Code (if other than 610)-telephone number.

35 NOTE All TMI local telephone lines and dedicated emergency lines (ML-8000 lines) to off-site facilities require the Middletown Central Office to be functional.

Local service to Middletown will not be available regardless of the method used below.

NOTE As the paging company utilizes the Harrsburg Central Office, group and individual pager service may not be available.

TMI Emergency Plan Implementing Procedure Title Emergency Notifications and Call Outs Number EPIP-TMI-.03 Revision No 37 Page 1 of 6 EXHIBIT 8 Emergency Status Log NOTE This exhibit should be used as a guide for transmittal of information to the NRC when the Emergency Response Data System is unavailable Communicator mobility available through the use of the cordless head-set in the Control RoomIECC will allow this exhibit to be completed as and if needed after contact with the NRC has been established. Do not exceed the one hour notification time limit.

NOTE If transmitting this information to the Region I Incident Response Center, it may be more efficient to telecopy these sheets to the telecopier number provided in the "Additional Assistance and Notification" procedure (EPIP-TMI-.06).

A Type of Event (Check the appropriate area[s])

50.72 (non-emergency)

Site Area Emergency

-_Physical Security Unusual Event Alert General Emergency Transportation B.

Facilities Activated ECC EOF OSC TSC C.

Description of Emergency (Include basis for event and event details) 36 Safeguards Other

TMI Emergency Plan Implementing Procedure Title

ý-j Emeraencv Notifications and Call Outs EXHIBIT 8 Event Time:

Power Level Prior to the Event:

Present Power Level:

Has the Reactor tripped?

Were the Emergency Safeguards Systems actuated7 If so, which ones (Check as applicable)

Number EPIP-TMI-.03 Revision No.

37 Page 2 of 6 Yes / No Yes I No Mode of Actuation High Pressure Injection Low Pressure Injection Core Flood 4 psig Reactor Building Isolation a

Reactor Building Spray Actuated What is the status (mode) of the plant At Power Hot Standby Hot Shutdown Cooling Down Describe Coolinq Mode (Circle as required)

AUTO / MANUAL AUTO / MANUAL AUTO / MANUAL AUTO / MANUAL AUTO / MANUAL Other Information:

Reactor Pressure psig Reactor Temperature _

F I.

Containment status (if applicable 37 D.

E F.

G.

H.

I.

TMI Emergency Plan Implementing Procedure Title Emerqencv Notifications and Call Outs EXHIBIT 8 J.

Is Off Site power available 0

If no, are both diesel generators operable K.

Have any personnel injuries occurred If so, is the injured person(s) contaminated

a.

What are the approximate radiation and/or contamination levels

_ mR/hr DPM/100 cm 2

L.

Are there excessive radiation levels and/or contamination levels If so, list below:

a.

Radiation levels (Whole Body)

b.

Contamination levels DPM/100 cm2 at

/

Location:

Plant Rad. Controls backup requested?

M.

Other problems Number EPIP-TMI-.03 Revision No 37 Page 3 of 6 Yes / No Yes / No Yes I No Yes I No Yes / No Yes I No N.

Plans 38 I

TMI Emergency Plan Implementing Procedure Title Emerqencv Notifications and Call Outs Number EPIP-TMI-.03 Revision No.

37 EXHIBIT 8 Pa

0.

The following additional information may be requested depending on the type of emergency.

Procedures In Use Personnel in Control Room

a.

Name

b.

Position Emergency Ventilation Status (Control Room)

DC Power Status Service Water Status

a.

Decay Heat River Water b

Reactor Building Emergency River Water

c.

Nuclear Services River Water

/

d.

Secondary Services River Water Primary Component Cooling Water Status

a.

Nuclear Services Closed Cooling Water

b.

Decay Heat Closed Cooling

c.

Intermediate Closed Cooling Secondary Component Cooling Water Status

a.

Secondary Services Closed Cooling Reactor Status

a.

Average Temp, 5 Highest Incore T/C's

/Trend

b.

Reactor Vessel Water Level

/Trend

c.

Emergency Boration Source

d.

Boron Concentration ge4 of 6 39

Title Emerqencv Notifications and Call Outs TMI Emergency Plan Implementing Procedure EXHIBIT 8 Number EPIP-TMI-.03 Revision No 37 Page 5 of 6 Primary Coolant System Status

a.

Reactor Coolant Pump Status

b.

Pressurizer Temperature

/Trend

c.

Safety Valve Status

d.

RCDT (also called PRTR or PDT) Level

/Pressure

e.

Loop Temperatures (Wide Range)

/Trend

f.

Subcooling Margin Loop Margin Incore Margin

g.

RCS Activity Gas Concentrations Specific Activity Total Containment Status

a.

Pressure Dose Equivalent 1-131 b.

C.

d.

e.

Sump Levels Sump Flood Hydrogen Concentration RB Spray Status LOCA Monitor Status RM-G22/23 Additional Rad Data should be requested over the Health Physics Network (HPN Line).

ECCS Status a

Makeup Pump Status/Indication (also called HPSI or Charging Pump Data) 40

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 8 Page 6 of 6 b

Decay Heat Removal Pump Statuslindication (also called LPSI or RHR Pump Data)

Secondary Plant Status

a.

Steam Generator Levels OTSG "A" OTSG "B"

b.

Steam Generator Pressures OTSG "A" OTSG "B"

c.

Steam Generator Status Tube Leakage (OTSG "A"/"B")

Isolated Cooling Supply

1.

Normal Feedwater Flow Rate

2.

Emergency (Auxiliary) Feedwater Flow Rate Cooling Sink

1.

Atmospheric Dump Valves 2

Turbine Bypass Valves

d.

Condensate Storage Tank Levels CO-T-1A CO-T-1B_

41

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 9 Page 1 of 12 CALL OUT OPERATIONS NOTE This exhibit and Emergency Report Form, Part 2 are required to perform the following steps.

1.0 Obtain the current "TMI-1 Initial Response Emergency Organization and Emergency Support Organization Duty Roster" from the Shift Manager's Office.

2.0 If the declaration is an Unusual Event with radiological considerations, THEN call out the duty RAC (Radiological Assessment Coordinator).

2.1 Obtain telephone numbers for Position 105 (RAC) on the Initial Response Emergency Organization Duty Roster and call the individual listed.

2.2 To individually page the duty RAC:

2.2.1 Dial the individual pager number.

2.2.2 Enter the call back number you wish the person to call.

(for example: 948*8778#)

2.3 After hearing the voice prompt "Thank you" or when the page tones are heard, wait 10 seconds and then hang up..

-3.0 IF the activation(s) were successfully initiated, THEN the automated call out system shall generate a "RESPONSE STATUS REPORT" every fifteen (15) minutes and transmit it to the ECC (or simulator for drills) and EOF facsimile (fax) machines.

3.1 After confirming that a "RESPONSE STATUS REPORT" is received, N/A Steps 7.0 through 12.0.

3.2 IF a "RESPONSE STATUS REPORT" IS NOT received within twenty-five (25) minutes after each activation attempt, THEN the automated call out system was NOT successfully activated. IMPLEMENT Exhibit 7, "Back-Up Communications,Section II - Equipment Failure Alternatives".

42

Title Emerqency TMI Emergency Plan Implementing Procedure Notifications and Call Outs Number EPIP-TMI-.03 Revision No 37 EXHIBIT 9 Page 2 of 12 4.0 In the event that the automated call out system did not function as-designed and the group pagers were manually activated AND the EP Pager Call Back Line (948-8801) was utilized, NA Steps 5.0 through 6.6.4 AND proceed directly to Step 7.0. Otherwise, proceed directly to Step 5.0.

5.0 Stop any lower level scenarios that are currently active in the automated call out system.

43 NOTE For the automated call out system to be fully effective, only one (1) scenario should be active. As a result, it may be necessary to stop any lower priority scenarios that may be running, e.g. if a Level 3 activation was initiated approximately 15-minutes after a Level 2 activation was initiated, stopping the Level 2 activation would allow the call out system to utilize its full resources to complete the Level 3 activation. DO NOT stop the highest level scenario that is currently activated (Level 3 is the highest level scenario followed by Level 2, and Level 1; Level 4 is the lowest level scenario. Also, at any given time, the latest scenario to be activated would be the highest-level scenario.)

Title Emergency Notifications and Call Outs TMI Emergency Plan Implementina Procedure Number EPIP-TMI-.03 Revision No 37 EXHIBIT 9 Page 3 of 12 Utilize the times for all scenarios NOT marked "NA" in the "Time Activation Initiated" columns in Step 2.4 of Exhibits 1-4 to complete columns 2, 3 and 4 of the following table:

APPLICABLE LEVEL (Level 3 is the highest level scenario followed by Level 2, and Level 1; Level 4 is the lowest level scenario) r T

ACTUAL EVENT or DRILL SCENARIO #

(Circle)

TIME ACTIVATED (T)

(NA If Not Applicable)

Place An "*" In The Space Next To The Highest Level Scenario Runninq)

TIME SCENARIO STOPPED (NA if "T" = NA or Scenario Has An ""

Next To It)

Level 1 401 / 405 Level 2 402 / 406 Level 3 403 I 407 Level 4 404 Utilize the scenario number information determined in Step 5.1 to stop any lower level scenarios, as necessary.

5.2.1 Lift the EP Pager Call Out Phone receiver or press the "SPEAKER" button.

5.2.2 Push the "Cancel" button.

5.2.3 After hearing the voice prompt: "This is the remote activation module. Please enter your scenario activation password followed by the pound (#) sign", enter the scenario number you wish to cancel followed by the pound (#) sign, e.g. "4 0 2 #".

5.2.4 After hearing the voice prompt: "To start a scenario enter the scenario ID followed by the pound (#) sign or press pound (#)

alone for more options", THEN promptly enter the same scenario number as Step 5.2.3 followed by the pound (#) sign, e.g. "4 0 2 #".

44 5.1 5.2

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 9 Page 4 of 12 5.2.5 IF the following voice prompt is heard : "To start the scenario press 3, to return to the main menu press pound (#)"THEN the scenario is not running.

5.2.5.1 Press the pound (#) button twice and hang-up the receiver. Place an "NA" in "Time Scenario Stopped" column for that scenario.

5.2.6 IF the following voice prompt is heard : "The scenario is currently active. Would you like to stop the scenario? Press "9" for "YES" or "6" for "NO" THEN the scenario is running.

5.2.6.1 Press "9" to stop the scenario.

5.2.6.2 After hearing the voice prompt: "The scenario will be stopped. To start a scenario press "l ", to stop a scenario press "2", to check scenario information press "3", to enter a different scenario activation password press "4", to end this call press V#", press the pound (#) button then hang-up the receiver or press the "SPEAKER" button.

5.2.7 If necessary, repeat Steps 5.2.1 through 5.2.6.2 for any additional lower priority scenarios.

45

Title Emergency Notifications and Call Outs TMI Emergency Plan Implementing Procedure Number EPIP-TMI-.03 Revision No.

37 EXHIBIT 9 Page 5 of 12 6.0 Review Emergency Response Organization response utilizing the "RESPONSE STATUS REPORTS" that are transmitted to the ECC facsimile machine.

For actual event activations, scenarios 401, 402 or 403, MONITOR the "RESPONSE STATUS REPORTS" as they are transmitted to the facsimile (fax) machine in the ECC. The reports list the positions that were staffed, any additional responders for each staffed position (denoted by an "X" behind the position number on the report), the required staffing level (identified on the report as "Persons Required" for the positions WITHOUT an "X"), and the individuals that staffed or are additional responders for each position along with the time that they called and their estimated travel time ("ETA").

6.1.1 For drill activations, scenarios 405, 406 or 407, MONITOR the "RESPONSE STATUS REPORTS" as they are transmitted to the facsimile (fax) machine in the ECC. The reports list the positions that were staffed, the required staffing level (identified on the report as "Persons Required"), and the individuals that staffed each position along with the time that they called and their estimated-time-of-arrival (ETA).

46 NOTES

1. The "400" series position numbers listed on the "RESPONSE STATUS REPORTS" DO NOT correspond with the TMI position numbers contained on the "TMI-1 Initial Response Emergency Organization and Emergency Support Organization Duty Roster". The TMI position numbers are located AFTER the position descriptions on the "RESPONSE STATUS REPORTS".
2. The following positions are staffed at each applicable level:

Level 1 - Position 111 Level 2 - Positions 101, 102, 103, 104, 105, 106, 107, 108, 109, 111,201,202, 301,302, 303, 304, 305, 307,401,601,610, 611 Level 3 - All Level 2 positions PLUS positions 501, 502, 503, 504, 505, 506, 507, 508, 509, 514, 704 Level 4 - All Level 3 positions EXCEPT positions 307, 507, 611,704.

6.1 I

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 9 Page 6 of 12 NOTE The "RESPONSE STATUS REPORTS" for drill activations, scenarios 405, 406 or 407, do not contain additional responders (denoted by an "X" behind the position number on the actual event reports).

6.2 After approximately thirty (30) minutes, utilize the most up-to-date "RESPONSE STATUS REPORT" to cross-off the staffed positions on the "TMI-1 Emergency Support Organization and Initial Response Emergency Organization Duty Roster". The number of names listed for each position (including the additional responders listed below the positions WITH an "X" behind the position) should match or exceed the number contained in the "Person Required" field of the positions that DO NOT contain an "X" behind the position number. IF any position contained on the "TMI-1 Emergency Support Organization and Initial Response Emergency Organization Duty Roster" IS NOT contained on the "RESPONSE STATUS REPORT" or DOES NOT contain the required number of responders, THEN utilize the information contained on the Shift Manager's office copy of the emergency response organization telephone list to page non-responding on-duty personnel:

6.2.1 Utilizing any touch-tone telephone, pickup the TELEPHONE RECEIVER and dial the individual pager number.

6.2.2 Enter the call back number, e.g., "948*8887#".

6.2.3 After hearing the voice prompt, "Thank You", or when the page tones are heard, wait ten (10) seconds and then hang-up the TELEPHONE RECEIVER.

6.3 If on-duty personnel do not respond to the paging attempts, utilize the home telephone information contained on the emergency response organization telephone list to contact them.

6.4 Replace non-responding duty personnel by utilizing Steps 6.2.1 through 6.2.3 to contact other qualified individuals indicated on the emergency response organization telephone list.

6.5 Periodically repeat Steps 6.2.1, 6.2.2 and 6.2.3 until all positions listed on the "TMI-1 Emergency Support Organization and Initial Response Emergency Organization Duty Roster" are staffed.

47

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No.

ErEmergency Notifications and Call Outs 37 EXHIBIT 9 Page 7 of 12 6.6 If activated, THEN check Emergency Response Facilities for emergency response personnel.

6.6.1 Shift Manager's Office/ECC/RAC, visual check.

6.6.2 Operations Support Center, call 8672 or 8833.

6.6.3 Technical Support Center, visual check.

6.6.4 Emergency Operations Facility, call 8903 or 9-657-0739.

7.0 Review Emergency Response Organization response using the EP Pager Call Back Line.

7.1 Dial "8424" on the EP Pager Call Back Line.

7.2 Press the star (*) key.

7.3 Enter 9901 for the on-duty mailbox.

7.4 Enter the mailbox password, 2255688.

7.5 At the main menu, press 1 to check unheard messages. At the end of a message, press 4 to replay, 7 to erase the message or 9 to save the message.

7.6 Check off responding individuals on duty roster.

7.7 To exit the mailbox, press the star (*) key until you hear "Goodbye" then hang up.

48

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No.

  • Emergency Notifications and Call Outs 37 EXHIBIT 9 Page 8 of 12 7.8 If Level 2, Level 3, or Level 4 button was selected and there are not a large number (Ž_20) of new voice mail messages in mailbox 9901, THEN hang up the EP Pager Call Back Line and re-activate the group pagers as follows:

7.8.1 Obtain the EP group pager telephone number from the Shift Manager's office safe or in the Control Room from the Control Room Supervisor desk cabinet.

7.8.2 Lift the EP Pager Call Out Phone receiver.

7.8.3 Manually dial the EP group pager number determined in Step 7.8.1.

7.8.4 After hearing the voice prompt "Please enter your caller password", promptly enter "948*8801"*#" where "#" is the applicable level. [Designated on Part 1 of the Emergency Report Form, i.e., Level 1, Level 2, Level 3, or Level 4].

S

_7.8.5 After hearing the voice prompt "Thank you" or when the page tones are heard wait 10 seconds and then Hang up.

7.8.6 If a failure of the group page system is suspected, THEN refer to the "Group Pager Activation Failure" section of Exhibit 7.

7.8.7 Dial "8424" on the EP Pager Call Back Line.

7.8.8 Press the star (*) key.

7.8.9 Enter 9901.

7.8.10 Enter password 2255688.

7.8.11 Press 1 to check unheard messages. At the end of a message, press 4 to replay, 7 to erase the message or 9 to save the message.

7.8.12 To exit the mailbox, press the star (*) key until you hear "Goodbye".

7.8.13 Check off the individual on the duty roster.

49

TMI Emergency Plan Implementinq Procedure Title Emerqencv Notifications and Call Outs EXHIBIT 9

+

Number EPIP-TMI-.03 Revision No 37 Page 9 of 12 Determine unmanned positions on the duty roster (i.e., the positions not checked).

8.1 If the unmanned position is part of the IREO/ESO THEN:

8.1.1 Dial 8424.

8.1.2 Press the star (*) key.

8.1.3 Enter mailbox number 0

9902 for IREO (Position numbers 101-401) 0 8.1.4 8.1.5 9903 for ESO (Position numbers 501 and higher)

Enter password 2255688.

Press 1 to check unheard messages. At the end of a message, press 4 to replay, 7 to erase the message or 9 to save the message.

8.1.6 To exit the mailbox, press the star (*) key until you hear "Goodbye".

9.0 If on-duty personnel have not responded, THEN contact non-responding duty personnel using the telephone numbers on the TMI Initial Response and Emergency Support Organization Telephone List. (Prioritize contacts to Coordinator positions and single person positions first.)

9.1 If necessary, THEN page non-responding personnel.

9.1.1 Dial the individual pager number.

9.1.2 Dial "948"8801#" for the call back number.

9.1.3 After hearing the voice prompt, "Thank you", or when the page tones are heard, wait 10 seconds and then Hang up.

10.0 Periodically repeat Steps 7.8.7 through 7.8.12 to review any new messages.

50 8.0 I

Number TMI Emergency Plan Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 9 Page 10 of 12 11.0 Replace non-responding personnel by contacting other qualified individuals indicated on the emergency response organization telephone list.

12.0 If activated, THEN check Emergency Response Facilities for emergency response personnel.

12.1 Shift Manager's Office/ECC/RAC. Visual check.

12.2 Operations Support Center. Call or 8672 or 8833.

12.3 Technical Support Center. Visual check.

12.4 Emergency Operations Facility. Call 8903 or 9-657-0739.

13.0 If notified by the RAC that BRP call back has not been received, THEN notify PEMA that BRP call back has not been received.

14.0 Contact the NRC Senior Resident Inspector.

14.1 Call J. Daniel Orr Site telephone 948-8253 Home telephone 1-610-932-3144 Pager number 9-280-0013 14.2 Read Emergency Report Form, Part 2 when contacted.

14.3 Record time contacted:

14.4 If contact cannot be made, THEN contact the NRC Resident Inspector.

14.4.1 Call Craig Smith Site telephone 948-8253 Home telephone 9-566-4757 Pager number 9-1-800-398-8135 14.4.2 Read Emergency Report Form, Part 2 when contacted.

14.4.3 Record time contacted:

I 14.5 If contact cannot be made, THEN note this in the "time contacted" blank in Step 14.3 and continue this procedure.

51

Title

'-ýEmergency TMI Emergency Plan ImDlementina Procedure Notifications and Call Outs Number n

........... *..........EPIP-TM I- 03 Revision No Notification an al us 1

52 EXHIBIT 9 Page 11 of 12 15.0 Confirm with Control Room personnel that the Public Information Duty Rep called in response to the group page.

15.1 If the Public Information Duty Rep did not call in, THEN perform the remainder of Step 15.

15.2 Obtain telephone numbers for Position 111 (Public Info Duty Rep) on the Initial Response Emergency Organization Duty Roster and call the individual listed.

15.3 Read Emergency Report Form, Part 2 to the Public Information Duty Representative.

15.4 Record the person contacted.

Name Time 15.5 To individually page the Public Information Duty Rep:

15.5.1 Dial the individual pager number.

15.5.2 Enter the call back number (for example: 948*8778#).

15.5.3 After hearing the voice prompt, "Thank you", hang up.

16.0 Contact the York Haven Power Station 16.1 Use the "EP Pager Call Out Phone" or Dial 9-848-7277 or 9-266-3654.

16.2 Read Emergency Report Form, Part 2.

16.3 Record the person contacted.

Name Time EPIP-TMI-.03

  • 7

Number TMI Emergency Plan "Implementing Procedure EPIP-TMI-.03 Title Revision No Emergency Notifications and Call Outs 37 EXHIBIT 9 Page 12 of 12 17.0 Contact the PECO Energy Resource Operator.

17.1 Use the "EP Pager Call Out Phone" or Dial 9-1-215-841-5141.

17.2 Read Emergency Report Form, Part 2.

17.3 Record the person contacted.

Name Time 18.0 If available, THEN inform the Emergency Director Assistant when all contacts have been completed.

19.0 Event Termination notifications.

19.1 NRC Resident Inspector contacted on Step 14.0.

Person Notified Time 19.2 York Haven Power Station contacted in Step 16.0.

Person Notified Time 19.3 PECO Energy Resource Operator contacted in Step 17.0.

Person Notified Time 20.0 Forward this procedure and all associated documentation to the Emergency Preparedness Department.

53