Text
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 2.1 Radioactive Liquid Waste Sampling and Analysis Program Batch Releases-: Each BatcW Eachl Batch Principal Gamma 5 x 10-'
Waste Tanks (Prior to (Prior to Emittersc I
Release) Release) 1-131 1 x 106 One Batch One Batch Dissolved and 1 x 104 Each Month Each Month Entrained Gases Each Batch Monthly H-3 1 x 10-
, Compositeb
- Gross alpha I 1 x10-7 Each Batch Quarterly Sr-89, Sr-90 5 x 108 Compositeb Fe-55 I x 16
- e. _
Continuous Releasee: ContinuoUsj,h,k Weekly Principal Gamma 5 x 10-7 Turbine Building Composite' Emittersc Sumps 1-131 1 x 104 I Weekly Grab Each Sample . Dissolved and 1 x 10-Sample Entrained Gases Continuousj,k Monthly H-3 I x 104 Compositef Gross Alpha 1 x 10-7 Continuousj,k Quarterly Sr-89, Sr-90 5 x 1 08 4
- Compositef 4-Fe-55 1 x 104 Continuous Releasee: Weekly Grab Each Sample Principal Gamma 5 x 10-7 Steam Generator Sample During Compositeb Emittersc Blowdown Releases' 1-131 1 x 104 Grab Sample Each Sample Dissolved and 1 x 106 Each Month Entrained Gases During Releases Weekly Grab Monthly H-3 1 x 10-Sample During Compositeb Releases Gross Alpha I x 10-7 Weekly Grab Quarterly Sr-89, Sr-90 5 x 108 Sample During Compositeb Releases' Fe-55 1 x 106
. PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 78o21 Table 2.1 Radioactive Liquid Waste Sampling and Analysis Program Table Notations
- a. The LLD is defined, for purposes of these controls, as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will d detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system, which may include radiochemical separation:
4.66 S E.V.2.22X106 LLD Y.exp(-AXA) where:
LLD = the "a priori" lower limit of detection (microCurie per unit mass or volume),
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (counts per minute),
E the counting efficiency (counts per disintegration),
V = the sample size (units of mass or volume),
2.22 x 106 = the number of disintegrations per minute per microCurie, Y = the fractional radiochemical yield, when applicable, X = the radioactive decay constant for the particular radionuclide (sec 1 ),
and AT = the elapsed time between the midpoint of sample collection and the time of counting (sec).
Typical values of E, V, Y, and AT should be used in the calculation.
It should be recognized that the LLD is defined as an a Driori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.
PR ARIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
H4 MANUAL (ODCM) REV: 17 Page 79 of 221 Table 2.1 Radioactive Liquid Waste Sampling and Analysis Program Table Notations [Co'nt'd]
- b. A coiposite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharge and in which the method of sampling employed results in a specimen which is representative of the liquids released.
- c. The principal gamma emitters for which the LLD specification will apply are exclusively the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144. This list does not mean that only the nuclides are to be detected and reported. Other peaks which are'measurable and identifiable, together with the above nuclides, SHALL also be identified and reported.
- d. Nuclides which are below the LLD for the-analyses should not be reported as being present at the LLD level. When unusual circumstances result in LLDs higher than required, the reasons SHALL be documented in the Annual Radioactive Effluent Report.
- e. A CONTINUOUS RELEASE is the discharge of liquid wastes of a non-discrete volume; e.g., from a volume of system that has an input flow during the continuous release.
- f. To be representative of the quantities and concentrations of radioactive materials in liquid effluents, samples SHALL be collected continuously in proportion to the rate of flow of the effluent stream. Prior to analyses, all samples taken for the composite SHALL be thoroughly mixed in order for the composite sample to be representative of the effluent release.
- g. A BATCH RELEASE is the discharge of liquid wastes of a discrete volume. Prior to sampling for analyses, each batch SHALL be isolated, and then thoroughly mixed to assure representative sampling.
- h. Daily grab samples from the turbine building sumps SHALL be collected and analyzed for principal gamma emitters, including 1-131, whenever primary to secondary leakage exceeds 150 gpd in any steam generator. This sampling is provided in lieu of continuous monitoring with automatic isolation.
- i. Grab samples SHALL be collected at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> when steam generator blowdown releases are being made and the specific activity of the secondary coolant is
>0.01 pCi/gram DOSE EQUIVALENT 1-131 or primary to secondary leakage exceeds 150 gpd.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 80 of 221 Table 2.1 Radioactive Liquid Waste Sampling and Analysis Program Table Notations [Cont'd]
- j. A continuous sample is one in which the sampling media is in place at all times during the release period, with the exception of periods necessary to change sampling media and scheduled short term equipment maintenance. If the sample media is not in place during the entire release period, an explanation of the occurrence, actions taken to restore the sampler and to prevent recurrence, and a summary description to explain the occurrence's effect on the analysis validity SHALL be included in the Annual Radioactive Effluent Report.
- k. Continuous samples of the Turbine Building Sumps are collected via on-line composite samplers. These samplers function on timers and collect a predetermined volume of effluent whenever the TBS pumps are in operation. Samples from these compositors are collected daily and saved for the preparation of a weekly composite prepared utilizing volumes proportional to the sample volumes collected daily by the compositor.
If the use of a submersible pump is necessary to maintain sump level, that pump should be positioned above the normal TBS pump controlling level and include a timer to allow the calculation of the additional release volume.
.~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~K
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 2.2 Radioactive Liquid Effluent Monitoring Instrumentation MINIMUM CHANNELS INSTRUMENT OPERABLE APPLICABILITY ACTION
- 1. Gross Radioactivity Monitors Providing Automatic Termination of Release
- a. Liquid Radwaste Effluent Line 1 During releases 1
- b. Steam Generator Blowdown 1/Unit During releases 2 Effluent Line
- 2. Flow Rate Measurement Devices
- a. Liquid RadwasteEffluent Line ; During releases 4 requiring throttling of flow
- b. Steam Generator Blowdown Flow 1/Gen During releases 4
- 3. Continuous Composite Samplers
- a. Each Turbine Building Sump 1/Unit During releases 3 Effluent Line
- 4. Discharge Canal Monitor I At all times 6
- 5. Tank'Level Monitor
- a. Condensate Storage Tanks - 1/Unit' When tanks are 5 in use
- b. Temporary Outdoor Tanks' Holding I/Tank When tanks are 5 Radioactive Liquid in use
- 6. Discharge Canal Flow System (Daily NA At all times determination and following changes in flow)
PRAJRIE ISLAND NUCLERAR GENEFRATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 .I MANUAL (ODCM) REV: 17
______________________________________________________ Pag e 82 o f 221 Table 2.2 Radioactive Liquid Effluent Monitoring Instrumentation Table Notations ACTION 1 With the number of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases may continue for up to 14 days provided that prior to each release:
- a. At least two independent samples are analyzed in accordance with Specification 2.2.1, and
- b. At least two technically qualified members of the Facility Staff independently verify the release rate calculations and discharge line valving.
Otherwise, suspend release of radioactive effluents via this pathway.
ACTION 2 With the number of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided grab samples are analyzed for gross radioactivity (beta or gamma) at a limit of detection of at least 10-7 [iCi/gram:
- 1. At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> when the specific activity of the secondary coolant is
>0.01 jtCi/gram DOSE EQUIVALENT 1-131, or
- 2. At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the specific activity of the secondary coolant is
<0.01 ,uCi/gram DOSE EQUIVALENT 1-131.
ACTION 3 With the numbers of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided that, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, grab samples are collected and saved for weekly composition and analysis in accordance with Table 2.1.
ACTION 4 With the number of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during actual releases. Pump curves may be used to estimate flow.
ACTION 5 With the number of channels Operable less than required by the Minimum Channels Operable requirement, liquid additions to the tank may continue for up to 30 days provided the tank liquid level is estimated during all liquid additions.
ACTION 6 With the numbers of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided that, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, grab samples are collected and analyzed for gamma emitters.
-PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCED)URE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 83 of 221 Table 2.3 Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Liquid Radwaste Etfluent uaiiy during Prior to eacn .Quarterly() At least once every Line Gross Radioactivity releases release 18 months(3)
Monitor Liquid Radwaste Effluent Daily during At least once every Line Flow Instrument releases 18 months Steam Generator Blowdown Daily during Monthly Quarterly(" At least once every Gross Radioactivity Monitors releases 18 months(3)
Steam Generator Blowdown Daily during _ At least once every Flow releases . 18 months Turbine Building Sump Daily during _
Continuous Composite releases Samplers (Includes sample volume check) .
Discharge Canal Monitor Daily during Monthly Quarterly(2) At least once every releases 18 months(3)
Discharge Canal Daily during At least once every Flow Instruments releases 18 months Condensate Storage Tank Daily Quarterly At least once every Level Monitors 18 months Level Monitors for Daily when in use Quarterly when in At least once every Temporary Outdoor Tanks use 18 months when in Holding Radioactive Liquid : - :- use I.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 84 of 221 Table 2.3 Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Table Notations
- 1. The CHANNEL FUNCTIONAL TEST SHALL also demonstrate that automatic isolation of this pathway and control room annunciation occurs if any of the following conditions exists:
- a. Instrument indicates measured levels above the alarm/trip setpoint.
- b. Circuit failure (if provided).
- c. Instrument indicates a downscale failure (if provided).
- d. Instrument controls not set in operate mode (if provided).
- 2. The CHANNEL FUNCTIONAL TEST SHALL also demonstrate that alarm annunciation occurs if any of the following conditions exists:
- a. Instrument indicates measured levels above the alarm/trip setpoint.
- b. Circuit failure (if provided).
- c. Instrument indicates a downscale failure (if provided).
- d. Instrument controls not set in operate mode (if provided).
- 3. The initial CHANNEL CALIBRATION SHALL be performed using one or more of the reference standards certified by the National Institute of Standards and Technology or using sources traceable to NIST standards. These standards SHALL permit calibrating the system over its intended range of energy and measurement range. For subsequent CHANNEL CALIBRATIONS, sources that have been related to the initial calibration SHALL be used.
- 4. The CHANNEL CHECK SHALL consist of verifying indication of flow during periods of release. A CHANNEL CHECK SHALL be made at least once daily on any day on which continuous, periodic, or batch releases are made.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 TABLE3iRPage 85 of 221 TABLE 3.1 Radioactive Gaseous Waste Sampling and Analysis Program CONTINUOUS RELEASE Weekly ',. Weekly Principal Gamma x104 Points: Gas Grab Sample Emitters e
, i, h Weekly c 1-131, 1-133 1 x 1012 Plant Vents: Continuous Charcoal Sample g,.ih Weekly c Principal Gamma I x 10-1 Unit 1 Aux Bldg.
Unit 2 Aux Bldg. Continuous Particulate Emitters e Radwaste Bldg. - Sample .
Spent Fuel Pool g, i h Monthly H-3 1 x 1O4 Unit 1 Shield Bldg. Continuous Silica Gel Unit 2 Shield Bldg. Sample g,i,h Each Gross Alpha I x 101 Continuous Particulate Sample g,I.h Quarterly d Sr-89, Sr-90 I x lo-,
Continuous Particulate
- __ Composite 9 Noble Gas Noble Gases, 1 x104 Continuous Monitor Gross beta and 4-gamma 1-Atmospheric Steam Daily J Releases k Grab Sample Each Principal Gamma During Release Sample Emitters e 5 x 10-7 1-131, 1-133 I x 1o4 Daily I Grab Sample Monthly I During Release Composite H-3 j xi04 Gross Alpha 1x 10-7 Daily J Quarterly ' Sr-89, Sr-90 5 x 1 08 Grab Sample Composite During Release
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page
_ _ _ _ _ __ 86 of 221 Table 3.1 Radioactive Gaseous Waste Sampling and Analysis Program Prior to each Purge Sample Emitters (Prior to Release)
Grab9g,m'Each H-3 x 4O Prior to Release and Sample Continuous Grabg9-m Charcoal 1-131, 1-133 1x 10-12 Prior to Release and Sample Continuous Grab9 hm,Particulate Principal Gamma I x 10-Prior to Release and Sample Emitters e Continuous Grabg9 h.m Each Gross Alpha 1 x 10-Prior to Release and Particulate Continuous Sample Grab9 h m Quarterly d Sr-89, Sr-90 1 x 1o-',
Prior to Release and Particulate Continuous Composite Waste Gas Gas Grab Sample Each Principal Gamma 1x Storage Tanks Prior to each Sample Emitters Release (Prior to Release)
Grab Sample Each H-3 1 x 106 Prior to each Sample Release (Prior to Release)
PRAIRIE ISLAND NUCLEAR GENERATING PLANT .HPROCEDURE Table 3.1 - Radioactive Gaseous Waste Sampling and Analysis Program Table Notations
- a. The LLD is defined, for purposes of these controls, as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system, which may include radiochemical separation:
4.66 -
LLD = Sb E.V 2.22X10 6 eY exp (-XAt) where:
LLD = the "a priori" lower limit of detection (microCurie per unit mass or volume.
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (counts per minute).
E = the counting efficiency (counts per disintegration),
V = the sample size (units of mass or volume),
2.22 x 106 = the number of disintegrations per minute per microCurie, Y = the fractional radiochemical yield, when applicable, X = the radioactive decay constant for the particular radionuclide (sec-1 ), and At = the elapsed time between the midpoint of sample collection and the time of counting (sec).
Typical values of E, V, Y, and At should be used in the calculation.
It should be recognized that the LLD is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 88 of 221 Table 3.1 - Radioactive Gaseous Waste Sampling and Analysis Program Table Notations [Cont'd]
- b. Grab samples taken at the ventilation exhausts are generally below minimum detectable levels for most nuclides with existing analytical equipment. If this is the case, PWR GALE Code noble gas isotopic ratios may be assumed.
- c. With >1 Cigm DOSE EQUIVALENT 1-131 in either Unit 1 or Unit 2 reactor coolant system, the iodine and particulate collection devices for all release points SHALL be removed and analyzed daily until it is shown that a pattern exists which can be used to predict the release rate. Sampling may then revert to weekly. When samples collected for one day are analyzed, the corresponding LLD's may be increased by a factor of 10.
Samples SHALL be analyzed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after removal.
- d. To be representative of the average quantities and concentrations of radioactive materials in particulate form in gaseous effluents, samples should be collected in proportion to the rate of flow of the effluent streams.
- e. The principal gamma emitters for which the LLD control applies include the following radionuclides: Kr-87, Kr-88, Xe-1 33, Xe-1 33m, Xe-1 35, and Xe-1 38 for noble gas analysis and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144 in iodine and particulate analysis. This list does not mean that only these nuclides are to be considered. Other gamma peaks that are identifiable, together with those of the above nuclides, SHALL also be detected and reported.
- f. Nuclides which are below the LLD for analyses should not be reported as being present at the LLD level for that nuclide. When unusual circumstances result in LLD's higher than reported, the reasons SHALL be documented in the Annual Radioactive Effluent Report.
- g. For continuous samples, the ratio of the sample flow rate to the samples stream flow rate SHALL be known for the time period sampled (Conservative assumptions may be used). Design flow rates may be used for building exhaust vent flow rates.
- h. A continuous sample is one in which the sampling media is in place at all times during the release period, with the exception of periods necessary to change sampling media and scheduled short term equipment maintenance of two hours or less. If the sample media is not in place during the entire release period (except as described above), an explanation of the occurrence, actions taken to restore the sampler and to prevent reoccurrence, and a summary description to explain the occurrence's effect on the analysis validity SHALL be included in the Annual Radioactive Effluent Report.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT I-. H PROCEDURE Table 3.1 Radioactive Gaseous Waste Sampling and Analysis Program Table Notations [Cont'd]
- i. Releases are made via the shield building vents only during PURGING, or operation of special ventilation systems. When ventilation fans in any vent path are not in service for the entire sample period, in lieu of weekly removal and analysis of iodine and particulate collection devices, these devices may be removed and analyzed following each release provided that the release lasts less than one week. Releases made via the plant ventilation paths as a result of routine surveillance tests, operational testing or scheduled short term maintenance activities of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or less do not require special sampling and analysis provided that plant conditions do not indicate the completion of these activities would cause an increase in the release of activity. Removal and analysis of collection devices is not required if releases are not being made.
- j. Grab samples for atmospheric steam releases are representative liquid grab samples from the respective steam generator.
- k. Atmospheric steam releases are the timed releases of steam from the steam generators to the atmosphere via either the power operated reliefs, steam dump valves or flash tank vents. It does not include steam dumped via the condenser.
I. A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of steam released and in which the method of sampling employed results in a specimen which is representative of the total steam released form the respective steam generator.
- m. Containment Purges includes PURGE releases with either the Inservice Purge or Containment Purge Fans and also VENTING of containment utilizing the Post Loca Vent System. When the release is completed via the Post Loca Vent, the pre-release tritium, particulate and charcoal samples should be used for all analyses, and continuous samples collected during the release are not required. During Cold Shutdown periods, the availability of ventilation systems and the position of containment air-lock doors may require that portions of the required samples be collected with installed continuous monitors or portable sampling equipment.
- PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
______ Page 90 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK "I
I i
i i
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 3.2 Radioactive Gaseous Effluent Monitoring Instrumentation MINIMUM CHANNELS INSTRUMENT, OPERABLE APPLICABILITY ACTION
- 1. Waste Gas Holdup-System Explosive Gas -2 During system 2 (Oxygen) Monitors operation
- 2. Effluent Release Points Unit 1 Aux Bldg.
Unit 2 Aux Bldg.
Rad Waste Bldg.
Spent Fuel Pool Unit 1 Shield Bldg.
Unit 2 Shield Bldg.
- a. Noble Gas Activity Monitor* I During releases 4,5,7
- b. Iodine Sampler Cartridge I During releases 3
- c. Particulate Sampler Filter I During releases 3
- d. Sampler Flow Integrator. During releases 1
- 3. Air Ejector Noble Gas Monitors 1 During power 6 (Each Unit) operation
- Noble gas activity monitors providing automatic termination of releases (except the Radwaste Building which has no automatic isolation function).
.PRAIRIE ISLANJD NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
! lOFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 F S l Page 92 of 221 Table 3.2 Radioactive Gaseous Effluent Monitoring Instrumentation Table Notations ACTION 1 With the number of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided the flow rate is estimated at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
Otherwise, suspend release of radioactive effluents via this pathway.
ACTION 2 With the number of channels Operable less than required by the Minimum Channels Operable requirement, operating of this system may continue for up to 14 days.
With two channels inoperable, manually isolate the oxygen addition line.
ACTION 3 With the numbers of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided samples are collected with auxiliary sampling equipment as required in Table 3.1.
ACTION 4 With the number of channels Operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue for up to 30 days provided grab samples are taken at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
ACTION 5 With the number of channels Operable less than required by the Minimum Channels Operable requirement, immediately suspend Purging of radioactive effluents via this pathway during periods when containment integrity is required or the primary system is initially opened to the atmosphere. (applicable to Reactor Building Vents)
ACTION 6 With the number of channels Operable less than required by the Minimum Channels Operable requirement, air ejector operation may continue for up to 30 days provided grab samples are taken at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
ACTION 7 With the number of channels operable less than required by the Minimum Channels operable requirement, the contents of the waste gas decay tanks may be released to the environment for up to 14 days provided that prior to initiating the release:
- a. At least two independent samples of the tank's contents are analyzed, and
- b. At least two technically qualified members of the Facility Staff independently verify the release rate calculations and discharge valve lineup; Otherwise, suspend release of radioactive effluents via this pathway (applicable to Unit 2 Auxiliary Building Vent).
PRAIRIE ISLAND NUCLEAR GENERATiNG PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 I-IMANUAL (ODCM) REV: 17
________________@S.Xi','H^a---g ........... Page 93 of 221 Table 3.3 - Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Waste Gas Holdup System Daily during Monthly(2) Quarterly(5)
Explosive Gas (Oxygen) system operation Monitors Effluent Release Points Unit 1 Aux Bldg.
Unit 2 Aux Bldg.
Rad Waste Bldg.
Spent Fuel Pool Unit 1 Shield Bldg.
Unit 2 Shield Bldg.
Noble Gas Activity - 'Daily during Monthly* Quarterly(') At least once every Monitor (4) releases 18 months( 3 )
(Except Radwaste Building)
Noble Gas Activity Monitor Daily during Monthly Quarterly(2 ) At least once every Radwaste Building (4) releases 18 months(3)
Iodine and Particulate Weekly Samplers Sampler Flow Rate Monitor Weekly _ At least once every 18 months Air Ejector Noble Gas Daily during Monthly Quarterly(2) At least once every Monitors (Each Unit) - releases 18 months( 3 )
- A SOURCE CHECK of the applicable nobles gas monitor SHALL be conducted prior to each waste gas decay tank or containment purge release.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 94 of 221 Table 3.3 - Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Table Notations
- 1. The CHANNEL FUNCTIONAL TEST SHALL also demonstrate that automatic isolation of this pathway and control room alarm annunciation occurs if any of the following exists.
- a. Instrument indicates measured levels above the alarm/trip setpoint.
- b. Circuit failure (if provided).
- c. Instrument indicates a downscale failure (if provided).
- d. Instrument controls not set in operate mode (if provided).
- 2. The CHANNEL FUNCTIONAL TEST SHALL also demonstrate that alarm annunciation occurs if any of the following conditions exists:
- a. Instrument indicates measured levels above the alarm/trip setpoint.
- b. Circuit failure (if provided).
- c. Instrument indicates a downscale failure (if provided).
- d. Instrument controls not set in operate mode (if provided).
- 3. The initial CHANNEL CALIBRATION SHALL be performed using one or more of the reference standards certified by the National Institute of Standards and Technology or using sources traceable to NIST standards. These standards SHALL permit calibrating the system over its intended range of energy and measurement range. For subsequent CHANNEL CALIBRATIONS, sources that have been related to the initial calibration SHALL be used.
- 4. Noble gas monitor in the Radwaste Building vent not provided with automatic isolation trip.
- 5. The CHANNEL CALIBRATION SHALL include the use of a nitrogen zero gas and an oxygen span gas with a nominal concentration suitable for the range of the instrument.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
.P _ ag e 95 of 221 Table 4.1 Liquid Source Terms Mo-99 2E-4 6.42E-3 1.415E-2 1-131 1E-5 3.061E-2 4.11E-2 Te-132 9E-5 2.12E-3 3.61 E-3 1-132 1E-3 2.83E-3 1.88E-2 1-133 1E-6 2.365E-2 4.856E-2 Cs-134 9E-6 1.464E-1 4.047E-2 1-135 3E-4 4.84E-3 1.792E-2 Cs-136 6E-5 5.743E-2 1.862E-2 Cs-1 37 1E-5 8.214E-2 2.69E-2 All Others 1E-7 0 2E-5 H-3 1E-2 1.89E2 1.41 E2 Noble gases 2E-4 _
TOTAL 1.894E2 1.412E2
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 96 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT .H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 97 of 221 Table 4.2 - Adult Ingestion Dose Values (At) for the Prairie Island Nuclear Generating Plant (MremlHr Per pjCiIml)
NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 O.OOE-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 C-14 3.13E 04 6.26E 03 6.26E 03 6.26E 03 6.26E 03 6.26E 03 6.26E 03 NA-24 4.07E 02 4.07E 02 4.07E 02 4.07E 02 4.07E 02 4.07E 02 4.07E 02 CR-51 O.OOE-01 O.OOE-01 1 27E 00 7.61 E-01 2.81 E-01 1.69E 00 3.20E 02 MN-54 O.OOE-01 4.38E 03 8.35E 02 0.OOE-01 1.30E 03 O.OOE-01 1.34E 04 MN-56 O.OOE-01 1.10E 02 1.95E 01 O.OOE-01 1.40E 02 O.OOE-01 3.51 E 03 FE-55 6.58E 02 4.55E 02 1.06E 02 O.OOE-01 O.OOE-01 2.54E 02 2.61 E 02 FE-59 1.04E 03 2.44E 03 9.36E 02 O.OOE-01 O.OOE-01 6.82E 02 8.14E 03 CO-57 O.OOE-01 2.1 OE 01 3.48E 01 -O.OOE-01 O.OOE-01 O.OOE-01 5.32E02 CO-58 O.OOE-01 8.92E 01 2.OOE 02 O.OOE-01 O.OOE-01 O.OOE-01 1.81 E 03 CO-60 O.OOE-01 2.56E 02 5.65E 02 .OOE-01 O.OOE-01 O.OOE-01 4.81 E 03 NI-63 3.11E 04 2.16E 03 1.04E 03 O.OOE-01 O.OOE-01 O.OOE-01 4.50E 02 NI-65 1.26E 02. 1.64E 01 7.49E 00 O.OOE-01 O.OOE-01 O.OOE-01 4.17E 02 CU-64 O.OOE-01 9.97E 00 4.68E 00 O.OOE-01 2.51 E 01 O.OOE-01 8.50E 02 ZN-65 2.32E 04 7.37E 04 3.33E 04 O.OOE-01 4.93E 04 0.OOE-01 4.64E 04 ZN-69 4.93E 01 9.43E 01 6.56E 00 0.OOE-01 6.13E 01 O.OOE-01 1.42E 01 BR-83 O.OOE-01 O.OOE-01 4.04E 01 O.OOE-01 O.OOE-01 O.OOE-01 5.82E 01 BR-84 O.OOE-01 O.OOE-01 5.24E 01 O.OOE-01 O.OOE-01 O.OOE-01 4.11E-04 BR-85 O.OOE-01 O.OOE-01 2.15E 00 O.OOE-01 O.OOE-01 O.OOE-01 1.01 E-1 5 RB-86 O.OOE-01 1.01E 05 4.71 E 04 O.OOE-01 O.OOE-01 O.OOE-01 1.99E 04 RB-88 O.OOE-01 2.90E 02 1.54E 02 O.OOE-01 O.OOE-01 O.OOE-01 4.00 E-09 RB-89 O.OOE-01 1.92E 02 -1.35E 02 O.OOE-01 O.OOE-01 O.OOE-01 1.12E-11 SR-89 2.21 E 04 O.OOE-01 6.35E 02 0.OOE-01 O.OOE-01 O.OOE-01 3.55E 03 SR-90 5.44E 05 O.OOE-01 1.34E 05 O.OOE-01 O.OOE-01 O.OOE-01 1.57E 04 SR-91 4.07E 02 O.OOE-01 1.64E 01 O.OOE-01 O.OOE-01 O.OOE-01 1.94E 03 SR-92 1.54E 02 0.OOE-01 6.68E 00 O.OOE-01 O.OOE-01 O.OOE-01 3.06E 03 Y-90 5.76E-01 O.OOE-01 1.54E-02 O.OOE-01 O.OOE-01 O.OOE-01 6.10E 03 Y-91M 5.44E-03 O.OOE-01 2.11 E-04 O.OOE-01 O.OOE-01 O.OOE-01 1.60E-02 Y-91 8.44E 00 O.OOE-01 2.26E-01 0.OOE-01 O.OOE-01 O.OOE-01 4.64E 03 Y-92 5.06E-02 O.OOE-01 1.48E-03 O.OOE-01 O.OOE-01 O.OOE-01 8.86E 02 Y-93 1.60E-01 O.OOE-01 4.43E-03 I O.OOE-01 O.OOE-01 O.OOE-01 5.09E 03 ZR-95 2.40E-01 7.70E-02 5.21 E-02 O.OOE-01 1.21 E-01 O.OOE-01 2.44E 02 ZR-97 1.33E-02 2.68E-03 I1.22E-03 -0.OOE-01 4.04E-03 O.OOE-01 8.30E 02 NB-95 4.47E 02 2.48E 02 1.34E 02 O.OOE-01 2.46E 02 O.OOE-01 1.51 E 04 NB-97 3.76E 00 9.48E-01 3.46E-01 O.OOE-01 1.11E 00 O.OOE-01 3.50E 03 MO-99 O.OOE-01 1.03E 02 1.96E 01 0.OOE-01 2.34E 02 O.OOE-01 2.39E 02 TC-99M 8.87E-03 2.51 E-02 3.19E-01 O.OOE-01 3.81 E-01 1.23E-02 1.48E 01 TC-101 9.12E-03 1.31 E-02 1.29E-01 -.OOE-01 2.37E-01 6.72E-03 3.95E-14 RU-1 03 4.43E 00 O.OOE-01 1.91 E 00 O.OOE-01 1.69E 01 O.OOE-01 5.17E 02 RU-105 3.69E-01 O.OOE-01 1.46E-01 O.OOE-01 4.76E 00 O.OOE-01 2.26E 02 RU-1 06 6.58E 01 O.OOE-01 8.33E 00 O.OOE-01 1.27E 02 O.OOE-01 4.26E 03
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 I MANUAL (ODCM) REV: 17
_____________________________________________ Page 98 of 221 Table 4.2 - Adult Ingestion Dose Values (Ait) for the Prairie Island Nuclear Generating Plant (Mrem/Hr Per jiCiIml)
NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI RH-105 2.92E 00 2.12E 00 1.40E 00 0.OOE-01 9.OOE 00 0.OOE-01 3.38E 02 AG-11 OM 8.81 E-01 8.15E-01 4.84E-01 0.OOE-01 1.60E 00 0.OOE-01 2.9E 02 SB-124 6.74E 00 1.27E-01 2.66E-01 1.63E-02 0.OOE-01 5.23E 00 1.91 E 02 SB-125 5.34E 00 5.75E-02 1.07E 00 4.74E-03 0.OOE-01 5.58E 02 4.72E 01 SB-126 2.75E 00 5.60E-02 9.94E-01 1.69E-02 0.00E-01 1.69E 00 2.25E 02 TE-125M 2.57E 03 9.30E 02 3.44E 02 7.72E 02 1.04E 04 0.OOE-01 1.02E 04 TE-1 27M 6.48E 03 2.32E 03 7.90E 02 1.66E 03 2.63E 04 0.OOE-01 2.17E 04 TE-127 1.05E-02 3.78E 01 2.28E 01 7.80E 01 4.29E 02 0.OOE-01 8.31 E 03 TE-129M 1.10E 04 4.11E 03 1.74E 03 3.78E 03 4.60E 04 0.OOE-01 5.54E 04 TE-129 3.01 E 01 1.13E 01 7.33E 00 2.31 E 01 1.26E 02 0.OOE-01 2.27E 01 TE-131M 1.66E 03 8.10E 02 6.75E 02 1.28E 03 8.21 E 03 0.OOE-01 8.04E 04 TE-131 1.89E 01 7.88E 00 5.96E 00 1.55E 01 8.26E 01 0.OOE-01 2.67E 00 5TE-1 32 2.41 E 03 1.56E 03 1.47E 03 1.72E 03 1.50E 04 0.OOE-01 7.38E 04 I-130 2.71 E 01 8.01 E 01 3.16E 01 6.79E 03 1.25E 02 0.OOE-01 6.89E 01 1-131 1.49E 02 2.14E 02 1.22E 02 7.OOE 04 3.66E 02 0.OOE-01 5.64E 01 1-132 7.29E 00 1.95E 01 6.82E 00 6.82E 02 3.11E 01 0.OOE-01 3.66E 00 I-133 5.10E 01 8.87E 01 2.70E 01 1.30E 04 1.55E 02 0.OOE-01 7.97E 01 1-134 3.81 E 00 1.03E 01 3.70E 00 1.79E 02 1.64E 01 0.OOE-01 9.01 E-03 I-135 1.59E 01 4.17E 01 1.54E 01 2.75E 03 6.68E 01 0.OOE-01 4.70E 01 CS-134 2.98E 05 7.09E 05 5.79E 05 0.OOE-01 2.29E 05 7.61 E 04 1.24E 04 CS-136 3.12E 04 1.23E 05 8.86E 04 0.OOE-01 6.85E 04 9.38E 03 1.40E 04 CS-137 3.82E 05 5.22E 05 3.42E 05 0.00E-01 1.77E 05 5.89E 04 1.01 E 04 CS-138 2.64E 02 5.22E 02 2.59E 02 0.00E-01 3.84E 02 3.79E 01 2.23E-03 BA-1 39 9.29E-01 6.62E-04 2.72E-02 0.00E-01 6.19E-04 3.75E-04 1.65E 00 BA-1 40 1.94E 02 2.44E-01 1.27E 01 0.00E-01 8.30E-02 1.40E-01 4.00E 02 BA-141 4.51 E-01 3.41 E-0.4 1.52E-02 0.OOE-01 3.17E-04 1.93E-04 2.13E-10 BA-1 42 2.04E-01 2.1 OE-04 1.28E-02 0.OOE-01 1.77E-04 1.1 9E-04 2.37E-19 LA-140 1.50E-01 7.54E-02 1.99E-02 0.OOE-01 0.OOE-01 0.00E-01 5.54E 03 LA-142 7.66E-03 3.48E-03 8.68E-04 0.00E-01 0.OOE-01 0.OOE-01 2.54E 01 CE-141 2.24E-02 1.52E-02 1.72E-03 0.00E-01 7.04E-03 0.OOE-01 5.79E 01 CE-143 3.95E-03 2.92E 00 3.23E-04 0.00E-01 1.29E-03 0.OOE-01 1.09E 02 CE-144 1.17E 00 4.88E-01 6.27E-02 0.00E-01 2.90E-01 0.00E-01 3.95E 02 PR-143 5.51 E-01 2.21 E-01 2.73E-02 0.OOE-01 1.27E-01 0.OOE-01 2.41 E 03 PR-144 1.80E-03 7.48E-04 9.16E-05 0.OOE-01 4.22E-04 0.OOE-01 2.59E-10 ND-147 3.76E-01 4.35E-01 2.60E-02 0.OOE-01 2.54E-01 0.OOE-01 2.09E 03 W-187 2.96E 02 2.47E 02 8.65E 01 0.00E-01 0.OOE-01 0.OOE-01 8.10E 04 NP-239 2.85E-02 2.80E-03 1.54E-03 0.OOE-01 8.74E-03 0.00E-01 5.75E 02 The values in the above table are calculated utilizing an adult fish consumption of 21 Kg/yr.
PRAIRIE ISLAL NUCLEAR GENERATING PLANT ( C H PRIJ,EDURE NUMBER:
OFFSITE DOSE CALCULATION H4 H976fyi§A5^j 1ssEt-Xjilii>
,te tt$N^zziiai ;z£l'r! rtiji MANUAL (ODCM) REV: 17 Page 99 of 221 Table 5.1 - Monitor Alarm Setpoint Determination for PINGP l < i4 ,<;50 YSOURCE; X : <KZ~A~j' KEFFLUENiT~FLWURELEAE REESE',, ~ OURCEO V ATE A~;<~ ~ RAiiO*
MONITOR POINT~~~~;4'RELEASE, ITBE52:t XQsTi~ ' 1F~Tf) ~ ~ tf 1R-30 Aux. Bldg. Aux. Bldg.
and Vent - Unit 1 Unit 1 Exhaust Aux. Bldg. 3.38E-5 2.9E+4 0.2 1R-37 Air Ejector Air Ejector 3.38E-5 2.9E+4 Unit 2R-30 Aux. Bldg. Aux. Bldg. -
and Vent - Unit 2 Unit 2 Exhaust Aux. Bldg. 3.38E-5 4.1 E+4 0.3 2R-37 Gas Decay Xe-133 (100%) 1.32E-4 4.1 E+4 Tanks Air Ejector Air Ejector 3.38E-5 4.1E+4 Unit 2 1R-12 and Shield Bldg. Cont. - Units 1&2 1R-22 Vent - Unit 1 Purge, Unit 1 Shield Bldg. 1.32E-4 3.2E+4 0.3 Inservice Purge (Note 2) 2R-12 and Shield Bldg. Cont. - Unit 2 Shield Bldg. 1.32E-4 4.6E+3 0.3 2R-22 Vent - Unit 2 Inservice Purge R-35 Radwaste Bldg. Radwaste Bldg. Aux. Bldg. 3.38E-5 6.1E+3 0.1 Vent Exhaust R-25 and Spent Fuel Pool Spent Fuel Pool Air Aux. Bldg. 3.38E-5 1.8E+4 0.1 R-31 Air Vent Exhaust I Values listed for Tm are nominal values only. They may be adjusted as necessary to allow a reasonable margin to the monitor setpoint. Duplicate values of Tm are assigned to both Shield Building vents since only one containment will be purged at any one time. The assigned Tm values of all active release points SHALL NOT be greater than unity.
When purging the Unit I containment via the nservice purge system, the monitor setpoints may be based on -
4.6E+3 cfm for the duration of the release.
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.2 Gaseous Source Terms Kr-85m 3EO 2EO Kr-85 2EO 2.2E1 Kr-87 l EO Kr-88 5EO IEO 3EO Xe-131 m 2EO 2.1 E IEO Xe-1 33m 5EO 2E1 3EO Xe-133 3.7E2 2.7E3 2.3E2 Xe-1 35 8EO 6EO 5EO Xe-138 lEO __ _
TOTAL 3.97E2 2.77E3 2.44E2
"-" indicates that the release is less than 1 Ci/yr.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
_ ___ __ Page 102 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT I H PROCEDURE-Table 5.3 Critical Organ Dose Values (Pil) for Child H-3 1.12 E3 Cr-51 1.70 E4 Mn-54 1.58 E6 Fe-59 1.27 E6 Co-58 1.11 E6 Co-60 7.07 E6 Zn-65 9.95 E5 Rb-86 1.98 E5 Sr-89 2.16 E6 Sr-90 1.01 E8 Y-91 2.63 E6 Zr-95 2.23 E6 Nb-95 6.14 E5 Ru-1 03 6.62 E5 Ru-106 1.43 E7 Ag-I1 Om 5.48 E6 Te-127m 1.48 E6 Te-129m 1.76 E6 Cs-134 1.01 E6 Cs-136 1.71 E5 Cs-137 9.07 E5 Ba-140 1.74 E6 Ce-141 5.44 E5 Ce-144 1.20 E7 1-131 1.62 E7
PRAJRIE ISLAND NUCLEAR GENERATING PLANT .. ~;H PROCEDURE.
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 104 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.4 Dose Factors for Noble Gases
- Kr-83m 7.56E-02 1.93E+01 2.88E+02 Kr-85m 1.17E+03 1.46E+03 1.97E+03 1.23E+03 Kr-85 1.61 E+01 1.34E+03 1.72E+01 1.95E+03 Kr-87 5.92E+03 9.73+03 6.17E+03 1.03E+04 Kr-88 1.47E+04 2.37E+03 1.52E+04 2.93E+03 Kr-89 1.66E+04 1.01E+04 1.73E+04 1.06E+04 Kr-90 1.56E+04 7.29E+03 163E+04 7.83E+03 Xe-131 m 9.15E+01 4.76E+02 1.56E+02 1.I1 E+03 Xe-133m 2.51 E+02 9.94E+02 3.27E+02 1.48E+03 Xe-133 2.94E+02 3.06E+02 3.53E+02 1.05E+03 Xe-135m 3.12E+03 7.1 E+02 3.36E+03 7.39E+02 Xe-135 1.81 E+03 1.86E+03 1.92E+03 2.46E+03 Xe-137 1.42E+03 1.22E+04 1.51 E+03 1.27E+04 Xe-138 8.83E+03 4.13E+03 9.21 E+03 4.75E+03 Ar-41 8.84E+03 2.69E+03 9.30E+03 3.28E+03
- The listed dose factors are for radionuclides that may be detected in gaseous effluents.
All others are 0.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
____ Page 106 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-1 R Values for the Prairie Island Nuclear Generating Plant*
- Ground, All Ages PATHWAY = GROUND NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 C-14 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 Na-24 1.42E+10 1.42E+10 1.42E+10 -1.42E+10 1.42E+10 1.42E+10 1.42E+10 1.65E+10 P-32 b.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 Cr-51 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 5.51 E+06 Mn-54 1 .39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.63E+09 MN-56 9.04E+05 9.04E+05 9.04E+05 9.04E+05 9.04E+05 9.04E+05 9.04E+05 1.07E+06 Fe-55 O.OOE+00 -O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 Fe-59 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 3.21 E+08 Co-58 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 4.44E+08 Co-60 2.15E+10 2.15E+10 2.15E+10 2.15E+10 2.15E+10 2.15E+10 2.15E+10 2.53E+10 Ni-63 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ni-65 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 3.45E+05 Cu-64 6.12E+05 6.12E+05 6.12E+05 6.12E+05 6.12E+05 6.12E+05 6.12E+05 -6.93E+05 Zn-65 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 8.59E+08 Zn-69. O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-83 8.15E+01 8.15E+01 8.15E+01 8.15E+01 8.15E+01 8.15E+01 8.15E+01 1.18E+02 Br-84 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.36E+05 Br-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06' 1.03E+07 Rb-88 3.31 E+04 3.31 E+04 3.31 E+04 3.31 E+04 3.31 E+04 3.31 E+04 3.31 E+04 3.78E+04 Rb-89 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 I1.23E+05 1.23E+05 1.47E+05 Sr-89 2.26E+04 2.26E+04 2.26E+04 2.26E+04 2.26E+04 2.26E+04 2.26E+04 2.62E+04 Sr-90 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-91 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.51 E+06 Sr-92 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 8.63E+05 Y-90: 4.49E+02 4.49E+02 4.49E+02 4.49E+02 4.49E+02 4.49E+02 4.49E+02 5.30E+02 Y-91 M 1.OOE+05 1.OOE+05 1.OOE+05 1.OOE+05 I1.OOE+05 1.OOE+05 1.OOE+05 1.16E+05 Y-91 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.21 E+06 Y-92 .1.80E+04 I1.80E+04 1.80E+04 1.80E+04 1.80E+04 1.80E+04 1.80E+04 2.14E+04 Y-93 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 2.51 E+05 Zr-95 2.45E+07 2.45E+07 2.45E+07 2.45E+07 2.45E+07 2.45E+07 2.45E+07 2.84E+07 Zr-97 2.96E+05 2.96E+05 2.96E+05 2.96E+05 2.96E+05 2.96E+05 2.96E+05 3.45E+05 Nb-95 1.36E+08 1.36E+08 1.36E+08 1.36E+08 1.36E+08 1.36E+08 1.36E+08 1.61 E+08 Mo-99 4.OOE+05 4.OOE+05 4.OOE+05 4.OOE+05 4.OOE+05 4.OOE+05 4.00E+05 4.63E+05 Tc-99M 1.84E+04 1.84E+04 1.84E+04 1.84E+04 1.84E+04 1.84E+04 1.84E+04 2.11E+04 Tc-101 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.26E+04 Ru-103 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.26E+08 Ru-1 05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 7.21 E+05 Ru-106 4.17E+08 4.17E+08 4.17E+08 4.17E+08 4.17E+08 4.17E+08 4.17E+08 5.01 E+08 Ag-110M 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 4.01 E+09 Te-125M 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 2.13E+06 Te-127M 9.17E+04 9.17E+04 9.17E+04 9.17E+04 9.17E+04 9.17E+04 9.17E+04 1.08E+05 Te-127 2.96E+03 2.96E+03 2.96E+03 2.96E+03 2.96E+03 2.96E+03 2.96E+03 3.25E+03 Te-129M 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 2.31 E+07 Te-129 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 3.1 OE+04 Te-131M 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 9.46E+06
PRAIRIE ISLAND NUCLEAR GENERATING PLANTHPRCDE . . H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION MANUAL (ODCM) IREV:
H4 17 IIb
_______ _______ _______ ______P age 108 of 221 Table 5.5-1 R Values for the Prairie Island Nuclear Generating Plant*
- Ground, All Ages PATHWAY = GROUND NUCLIDE BONE LIVER T. BODY. THYROID KIDNEY LUNG GI-LLI SKIN Te-1 31 2.92E+04 2.92E+04. 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 3.45E+07 Te-1 32 4.24E2+06 4.24 E+06 4.24E2+06 4.24E+06 4.24 E+06 4.24E+06 4.24 E+06 4.98E+06 1-130 5.512E+06 5.512E+06 5.51 E+06 5.51 E+06 5.51 E+06 5.51 E+06 5.51 E+06 6.69 E+06 I-131 1.72E+07 1.72E+07 1.72E+07 1.722+07 1.72E+07 1.72E+07 1.72E+07 2.09E+07 1-132 1.25E4+06 I.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 I1.47E+06 1-133 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.98E+06 1-134 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 5.312E+05 1-135 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53 E+06 2.53E+06 2.95E+06 Cs-134, 6.85E+09 6.85E+09 6.85E+09 6.85E+09 6.85E+09 6.85E+09 6.85E+09 8.OOE+09 Cs-1 36 1.49E+08 1.492+08 1 .49E+08 1.49E+08 I1.49E+0a 1.49E+08 1.49E+08 1 .69E+08 Cs-i 37 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.20E+10 Cs-I 38 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3. 59 E+05 3.59E+05 4.10E+05 Ba-i 39 1.06E+05 1.062+05 1.06E+05 1.062+05 1.06E+05 1.06E+05 1.06E+05 1.19E+05 Ba-140 2.05E+07 2.052+407 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.35E+07 Ba-141 4.11 E+04 4.1 1E+04 4.1 1E+04 4.1 1E+04 4.1 1E+04 4.112E+04 4.112E+04 4.68E+04 Ba-142 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 5.112E+04 La-140 I1.92E+07 I1.92E+07 1 .92E+07 1.92E+07 1 .92E+07 I1.92E+07 1.92E+07 2.18E+07 La-142 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 9.12E+05 Ce-141 1.37E+07 1.372+07 I1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.54E+07 Ce-143 2.31 E+06 2.312E+06 2.31 E+06 2.31 E+06 2.312E+06 2.31 E+06 2.31 E+06 2.63E+06 Ce-144 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 6.96E+07 8.04E+07 Pr-I143 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.002+00 0.00 E+00 Pr-i144 1.83E+03 1.832+03 1.83E+03 1.83E+03 I1.83E+03 1.83E+03 1.832+03 2.1iiE+03 Nd-147 8.39E+05 8.39E+05 8.39E+05 8.39E+05 8.39E+05 8.39E+05 8.39E+05 1.01 E+06 W-1 87 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06- 2.73E+06 Np-239 1.7 1E+06 1.7 1E+06 1.71 E+06 1.71 E+06 1.71 E+06 1.71 E+06 1.71 E+06 1.98E+06 Co-57 1.89E+06 1.89E+06 1.89E+06 1.89E+06 1.89E+06 1.89E+06 1.89E+06 2.07E+06 Br-82 2. 14E+06 2.14E+06 2.14E+06 2.14E+06 2.14E+06 2.14E+06 2.14E+06 2.47E+06 Nb-97 1.76E+05 1.76E+05 1.762+05 1.76E+05 1.76E+05 1 .76E+05 1.76E+05 2.07E+05 Sb-1 24 5.98E+07 5.98E+07 5.98E+07 5.98E+07 5.98E+07~ 5.98E+07 5.98E+07 6.90E+07 Sb-125- 2.33E+09 2.33E+09 2.33E+09 2.33E+09 2.33E+09 2.33E+09 2.33E+09 2.63E+09 Sb-1 26 5.06E+08 5.06E+08 5.06E2+08 5.06E+08 5.06E+08 5.06E+08 5.06E+08 5.69E+08 R VALUES IN UNITS OF MREMIYR PER P.CI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMIYR PER jiCi/SEC FOR ALL OTHERS.
PMRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION l _H4_l MANUAL (ODCM) REV: 17
- Page 109 of 221 Table 5.5-2 R Values for the Prairie Island Nuclear Generating Plant*
- Vegetable, Adult PATHWAY = VEGETABLE AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 0.OOE+00 2.26E+03 2.26E+03 2.26E+03 2.26E+03 2.26E+03 2.26E+03. 2.26E+03 C-14 1.43E+10 2.87E+09 2.87E+09 2.87E+09 2.87E+09 2.87E+09 2.87E+09 O.OOE+00 Na-24 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 O.OOE+00 P-32 1.53E+09 1.03E+08 5.92E+07 O.OOE+00 O.OOE+00 O.OOE+00 1.72E+08 O.OOE+00 Cr-51 0.OOE+00 O.OOE+00 4.49E+04 2.75E+04 1.01 E+04 6.09E+04 1.1 5E+07 O.OOE+00 Mn-54 0.OOE+00 3.08E+08 5.87E+07 0.00E+00 9.16E+07 O.OOE+00 9.43E+08 O.OOE+00 MN-56 0.OOE+00 1.59E+01 2.83E+00 0.OOE+00 2.02E+01 O.OOE+00 5.09E+02 O.OOE+00.
Fe-55 2.OOE+08 1.38E+08 3.22E+07 0.OOE+00 0.OOE+00 7.69E+07 7.91 E+07 O.OOE+00 Fe-59 1.24E+08 2.90E+08 1.11 E+08 0.OOE+00 O.OOE+00 8.11E+07 9.68E+08 O.OOE+00 Co-58 0.OOE+00 2.99E+07 6.71 E+07 0.OOE+00 O.OOE+00 O.OOE+00 6.07E+08 O.OOE+00 Co-60 0.OOE+00 1.66E+08 3.67E+08 0.OOE+00 O.OOE+O0 O.OOE+00 3.13E+09 O.OOE+00 Ni-63 1.20E+08 8.31 E+08 4.02E+08 0.OOE+00 O.OOE+00 O.OOE+00 1.73E+08 O.OOE+00 Ni-65 6.16E+01 8.01 E+00 3.65E+00 0.OOE+00 O.OOE+00 O.OOE+00 2.03E+02 O.OOE+00 Cu-64 0.OOE+00 9.42E+03 4.42E+03 0.OOE+00 2.37E+04 O.OOE+00 8.03E+05 O.OOE+00 Zn-65 4.01 E+08 1.28E+09 5.77E+08 0.OOE+00 8.54E+08 O.OOE+00 8.04E+08 O.OOE+00 Zn-69 5.61 E-06 1 .07E-05 7.46E-07 0.OOE+00 6.97E-06 O.OOE+00 1.61 E-06 I.OOE+00 Br-83 0.OOE+00 O.OOE+00 9.95E-179 0.OOE+00 O.OOE+OO O.OOE+00 1.43E-178 2.OOE+00, Br-84 0.OOE+00 O.OOE+00 2.57E-1 1 0.OOE+00 O.OOE+00 O.OOE+00 2.02E-16 3.OOE+00 Br-85 0.OOE+00 O.OOE+00 5.88E-144 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 4.OOE+00 Rb-86. 0.OOE+00 2.21 E+08 1.03E+08 0.OOE+00 O.OOE+00 O.OOE+O0 4.36E+07 5.OOE+00 Rb-88 0.OOE+00 3.47E-22 1.84E-22 0.OOE+00 O.OOE+00 O.OOE+00 4.79E-33 6.OOE+00 Rb-89 0.OOE+00 3.34E-26 2.35E-26 0.OOE+00 O.OOE+OO O.OOE+00 1.94E-39 O.OOE+00 Sr-89 1.01 E+10 O.OOE+00 2.90E+08 0.OOE+00 O.OOE+00 O.OOE+00 1.62E+09 O.OOE+00 Sr-90 6.71 E+11 O.OOE+00 I.65E+11 0.OOE+00 O.OOE+00 O.OOE+00 1.94E+10 O.OOE+00 Sr-91 3.05E+05 O.OOE+00 1.23E+04 0.OOE+00 O.OOE+00 O.OOE+00 1.45E+06 O.OOE+00 Sr-92 4.27E+02 O.OOE+00 1.85E+01 0.OOE+00 O.OOE+00 O.OOE+00 8.47E+03 O.OOE+00 Y-90 1.51 E+02 O.OOE+00 4.06E+00 0.OOE+00 O.OOE+00 O.OOE+00 1.60E+06 O.OOE+00 Y-91 M 5.24E-09 O.OOE+00 2.03E-10 0.OOE+00 O.OOE+00 O.OOE+00 1.54E-08 O.OOE+00 Y-91 4.99E+06 O.OOE+O0 1.33E+05 0.OOE+00 O.OOE+00 O.OOE+00 2.74E+09 O.OOE+00 Y-92 4.87E-20 O.OOE+00 1.42E-21 0.OOE+00 O.OOE+00 O.OOE+00 8.52E-16 O.OOE+00 Y-93 1.70E+02 O.OOE+OO 4.68E+00 0.OOE+00 O.OOE+00 O.OOE+00 5.38E+06 O.OOE+00 Zr-95 9.67E+04 3.1OE+04 2.1OE+04 0.OOE+00 4.87E+04 O.OOE+00 9.83E+07 O.OOE+00 Zr-97 5.23E-03 1.06E-03 4.83E-04 0.OOE+00 1.59E-03 O.OOE+00 3.27E+02 O.OOE+00 Nb-95 1.40E+05 7.79E+04 4.19E+04 0.00E+00 7.70E+04 O.OOE+00 4.73E+08 O.OOE+00 Mo-99 0.OOE+00 7.60E+04 1.45E+04 0.OOE+00 1.72E+05 O.OOE+00 1.76E+05 O.OOE+00 Tc-99M 5.68E-12 1.61 E-11 2.05E-10 0.OOE+00 2.44E-10 7.87 E-12 9.50E-09 O.OOE+00 Tc-101 8.43E-31 1.21 E-30 1.19E-29 0.OOE+00 2.19E-29 6.20E-31 3.65E-42 O.OOE+00 Ru-1 03 4.72E+06 O.OOE+00 2.04E+06 0.00E+00 1.80E+07 O.OOE+00 5.52E+08 O.OOE+00 Ru-1 05 5.40E+01 O.OOE+00 2.13E+01 0.OOE+00 6.98E+02 O.OOE+00 3.30E+04 O.OOE+00 Ru-I 06 1.94E+08 O.OOE+00 2.46E+07 0.00E+00 3.75E+08 O.OOE+00 1.26E+10 O.OOE+00 Ag-1I0M 1.13E+07 1.05E+07 6.22E+06 0.OOE+00 2.06E+07 O.OOE+00 4.27E+09 O.OOE+00 Te-1 25M 1.21 E+08 4.39E+07 1.62E+07 3.64E+07 4.92E+08 O.OOE+00 4.83E+08 O.OOE+00 Te-1 27M 5.03E+08 1.80E+08 6.13E+07 1.29E+08 2.04E+09 O.OOE+00 1.69E+09 O.OOE+00 Te-127 5.87E+03 2.11 E+03 1.27E+03 4.35E+03 2.39E+04 O.OOE+00 4.63E+05 O.OOE+00
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 lll1!
MANUAL (ODCM) REV: 17 Page 110 of 221 Table 5.5-2 R Values for the Prairie Island Nuclear Generating Plant*
- Vegetable, Adult PATHWAY = VEGETABLE AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-129M 2.94E+08 1.1OE+08 4.65E+07 1.01 E+08 1.23E+09 0.00E+00 1.48E+09 0.00E+00 Te-129 8.06E-04 3.03E-04 1.96E-04 6.19E-04 3.39E-03 0.00E+00 6.09E-04 0.OOE+00 Te-131M 9.66E+05 4.72E+05 3.94E+05 7.48E+05 4.79E+06 0.OOE+00 4.69E+07 0.OOE+00 Te-1 31 1.60E-15 6.67E-1 6 5.04E-1 6 1.31 E-15 6.99E-15 0.OOE+00 2.26E-16 0.OOE+00 Te-1 32 4.59E+06 2.97E+06 2.79E+06 3.28E+06 2.86E+07 0.OOE+00 1.40E+08 0.OOE+00 1-130 3.92E+05 1.16E+06 4.56E+05 9.80E+07 1.80E+06 0.OOE+00 9.95E+05 0.OOE+00 1-131 8.08E+07 1.16E+08 6.62E+07 3.79E+10 1.98E+08 0.OOE+00 3.05E+07 0.OOE+00 1-132 5.77E+01 1.54E+02 5.40E+01 5.40E+03 2.46E+02 0.OOE+00 2.90E+01 0.OOE+00 1-133 2.09E+06 3.63E+06 1.11 E+06 5.33E+08 6.33E+06 0.OOE+00 3.26E+06 0.00E+00 1-134 9.70E-05 2.63E-04 9.42E-05 4.56E-03 4.19E-04 0.OOE+00 2.30E-07 0.OOE+00 1-135 3.90E+04 1.02E+05 3.77E+04 6.74E+06 1.64E+05 0.OOE+00 1.15E+05 0.OOE+00 Cs-134 4.55E+09 1.08E+10 8.84E+09 0.OOE+00 3.50E+09 1.16E+09 1.89E+08 0.OOE+00 Cs-1 36 4.20E+07 1.66E+08 1.19E+08 0.OOE+00 9.22E+07 1.26E+07 1.88E+07 0.OOE+00 Cs-1 37 6.64E+09 9.08E+09 5.95E+09 0.OOE+00 3.08E+09 1.02E+09 1.76E+08 0.OOE+00 Cs-1 38 3.94E-1 1 7.79E-1 1 3.86E-1i1 0.OOE+00 5.72E-1 1 5.65E-12 3.32E-16 0.OOE+00 Ba-1 39 2.86E-02 2.04E-05 8.39E-04 0.OOE+00 1.91 E-05 1.16E-05 5.08E-02 0.00E+00 Ba-140 1.28E+08 1.61 E+05 8.41 E+06 0.OOE+00 5.48E+04 9.23E+04 2.64E+08 0.OOE+00 Ba-141 5.08E-22 3.84E-25 1.71 E-23 0.OOE+00 3.57E-25 2.18E-25 2.39E-31 0.OOE+00 Ba-142 6.09E-39 6.27E-42 3.83E-40 0.OOE+00 5.29E-42 3.55E-42 8.58E-57 0.OOE+00 La-140 1.98E+03 9.97E+02 2.63E+02 0.OOE+00 0.OOE+00 0.OOE+00 7.32E+07 0.00E+00 La-142 2.03E-04 9.21 E-05 2.29E-05 0.OOE+00 0.OOE+00 0.OOE+00 6.72E-01 0.OOE+00 Ce-141 1.94E+05 1.31 E+05 1.49E+04 0.OOE+00 6.11E+04 0.OOE+00 5.03E+08 0.00E+00 Ce-143 9.98E+02 7.38E+05 8.17E+01 0.OOE+00 3.25E+02 0.OOE+00 2.76E+07 0.OOE+00 Ce-144 3.15E+07 1.32E+07 1.69E+06 0.OOE+00 7.81 E+06 0.OOE+00 1.07E+10 0.OOE+00 Pr-143 6.25E+04 2.51 E+04 3.10E+03 0.OOE+00 1.45E+04 0.OOE+00 2.74E+08 0.OOE+00 Pr-144 3.13E-26 1.30E-26 1.59E-25 0.OOE+00 7.32E-27 0.OOE+00 4.50E-33 0.OOE+00 Nd-147 2.73E+03 3.15E+03 1.89E+02 0.OOE+00 1.84E+03 0.OOE+00 1.51 E+07 0.OOE+00 W-187 3.81 E+04 3.18E+04 1.11E+04 0.OOE+00 0.OOE+00 0.OOE+00 1.04E+07 0.OOE+00 Np-239 1.43E+03 1.40E+02 7.74E+01 0.00E+00 4.38E+02 0.OOE+00 2.88E+07 0.OOE+00
- R VALUES IN UNITS OF MREM/YR PER pCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M 2 -MREM/YR PER i[CI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT - H PROCEDURE Table 5.5-3 R Values for the Prairie Island Nuclear Generating Plant*
-Vegetable, Teen PATHWAY = VEGETABLE AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 O.OOE+00 2.59E+03 2.59E+03 2.59E+03 2.59E+03 2.59E+03 2.59E+03 2.59E+03 C-14 2.32E+10 4.65E+09 4.65E+09 4.65E+09 4.65E+09 4.65E+09 4.65E+09 O.OOE+00 Na-24 2.1 OE+08 2.1OE+08 2.1OE+08 2.1 0E+08 2.1 OE+08 2.1 OE+08 2.1OE+08 O.OOE+00 P-32 1.75E+09 1 .09E+08 6.80E+07 O.OOE+00 O.OOE+00 O.OOE+00 1.47E+08 O.OOE+00 Cr-51 O.OOE+00 O.OOE+OO 6.1OE+04 3.39E+04 1.34E+04 8.71 E+04 1.03E+07 O.OOE+00 Mn-54 O.OOE+00 4.47E+08 8.86E+07 O.OOE+00 1.33E+08 O.OOE+00 9.17E+08 O.OOE+00 MN-56 O.OOE+00 1.44E+02 2.56E+00 O.OOE+00 1.82E+01 O.OOE+00 9.46E+02 O.OOE+00 Fe-55 3.1 OE+08 2.20E+08 5.13E+07 O.OOE+00 O.OOE+00 1.40E+08 9.53E+07 O.OOE+00 Fe-59 1.76E+08 4.1OE+08 1.58E+08 O.OOE+00 O.OOE+00 1.29E+08 9.70E+08 O.OOE+00 Co-58 O.OOE+00 4.25E+07 9.78E+07 O.OOE+00 O.OOE+00 O.OOE+00 5.85E+08 O.OOE+00 Co-60 O.OOE+00 2.48E+08 5.58E+08 O.OOE+00 O.OOE+00 O.OOE+00 3.23E+09 O.OOE+00 Ni-63 1.85E+10 1.31 E+09 6.27E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.08E+08 O.OOE+00 NI-65 5.74E+0i 7.33E+00 3.34E+00 O.OOE+00 O.OOE+00 O.OOE+00 3.98E+02 O.OOE+00 Cu-64 O.OOE+00 8.53E+03 4.01 E+03 O.OOE+00 2.16E+04 O.OOE+00 6.62E+05 O.OOE+00 Zn-65 5.36E+08 1.86E+09 8.68E+08 O.OOE+00 1.19E+06 O.OOE+00 7.88E+08 0.OOE+00 Zn-69 5.25E-06 1.OOE-05 7.OOE-07 O.OOE+00 6.54E-06 O.OOE+00 1.84E-05 O.OOE+00 Br-83 O.OOE+OO O.OOE+00 9.33 E-179 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 2.34E-1 1 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+O0 5.50E-144 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 2.76E+08 1.30E+08 O.OOE+00 O.OOE+00 O.OOE+00 4.08E+07 O.OOE+00 Rb-88 O.OOE+00 3.21 E-22 1.71 E-22 O.OOE+O0 O.OOE+00 O.OOE+00 2.75E-29 O.OOE+00 Rb-89 O.OOE+00 3.01 E-26 1.58E-26 O.OOE+00 O.OOE+00 O.OOE+00 4.61 E-35 O.OOE+00 Sr-89 1.54E+10 O.OOE+00 4.41 E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.83E+09 O.OOE+00 Sr-90 8.33E+1 I O.OOE+00 2.06 E+1 1 O.OOE+OO O.OOE+00 O.OOE+00 2.34E+10 O.OOE+00 Sr-91 2.85E+05 O.OOE+O0 1.13E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.29E+06 O.OOE+00 Sr-92 3.98E+02 O.OOE+Ob I.70E+01 O.OOE+00 O.OOE+00 O.OOE+00 1.01 E+04 O.OOE+00 Y-90 1.41 E+02 O.OOE+00 3.81 E+0 O.OOE+00 O.OOE+00 O.OOE+00 1.17E+06 0.OOE+OO Y-91M 4.88E-09 O.OOE+OO 1.87E-10 O.OOE+00 O.OOE+00 O.OOE+00 2.31 E-07 O.OOE+00 Y-91 7.64E+06 O.OOE+00 2.05E+05 O.OOE+00 O.OOE+00 O.OOE+00 3.13E+09 O.OOE+00 Y-92 4.57E-20 O.OOE+00 1.32E-21 O.OOE+00 O.OOE+00 O.OOE+00 1.25E-15 O.OOE+00 Y-93 1.59E+02 O.OOE+00 4.36E+O0 O.OOE+00 -O.00E+OO O.OOE+00 4.86E+06 O.OOE+00 Zr-95 8.67E+04 2.74E+04 1.88E+04 O.OOE+00 4.02E+04 O.OOE+00 6.31 E+07 O.OOE+00 Zr-97 4.84E-03 9.58E-04 4.41 E-04 O.OOE+00 1.45E-03 O.OOE+00 2.59E+02 O.OOE+OO Nb-95 1.89E+05 1.05E+05 5.78E+04 O.OOE+00 1.02E+05 O.OOE+00 4.49E+08 O.OOE+OO Mo-99 O.OOE+OO 6.97E+04 1.33E+04 O.OOE+00 1.60E+05 O.OOE+00 1.25E+05 O.OOE+00 Tc-99M 5.01 E-12 1.40E-11 1.81 E-10 O.OOE+00 2.08E-1 0 7.76E-12 9.18E-09 O.OOE+00 Tc-101 7.84E-31 1.11E-30 1.1OE-29 O.OOE+00 2.02E-29 6.79E-31 1.91 E-37 O.OOE+00 Ru-1 03 6.75E+06 O.OOE+00 2.89E+06 O.OOE+00 2.38E+07 O.OOE+00 5.64E+08 O.OOE+00 Ru-105 5.02E+01 O.OOE+00 1.95E+01 O.OOE+00 6.33E+02 O.OOE+00 4.05E+04 O.OOE+00 Ru-1 06 3.12E+08 O.OOE+00 3.93E+07 O.OOE+00 6.02E+08 O.OOE+00 1.50E+10 O.OOE+00 Ag-i1 OM 1.63E+07 1.54E+07 9.37E+06 O.OOE+00 2.94E+07 O.OOE+00 4.33E+09 O.OOE+00 Te-125M 1.86E+08 6.70E+07 2.49E+07 5.19E+07 O.OOE+00 O.OOE+00 5.48E+08 O.OOE+00 Te-127M 7.95E+08 2.82E+08 9.45E+07 1.89E+08 3.22E+09 O.OOE+00 1.98E+09 O.OOE+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) l REV: 17 F Page 112o21 Table 5.5-3 R Values for the Prairie Island Nuclear Generating Plant*
- Vegetable, Teen PATHWAY = VEGETABLE AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 5.53E+03 1.96E+03 1.19E+03 3.82E+03 2.24E+04 0.00E+00 4.27E+05 0.00E+00 Te-129M 4.23E+08 1.57E+08 6.70E+07 1.37E+08 1.77E+09 0.OOE+00 1.59E+09 0.OOE+00 Te-129 7.55E-04 2.81 E-04 1.84E-04 5.39E-04 3.17E-03 0.OOE+00 4.13E-03 0.OOE+00 Te-131M 8.94E+05 4.29E+05 3.58E+05 6.45E+05 4.47E+06 0.OOE+00 3.44E+07 0.OOE+00 Te-131 1.48E-15 6.11E-16 4.64E-1 6 1.14E-15. 6.49E-1 5 0.OOE+00 1.22E-16 0.00E+00 Te-132 4.17E+06 2.64E+06 2.46E+06 2.78E+06 2.53E+07 0.00E+00 8.37E+07 0.OOE+00 1-130 3.50E+05 1.01 E+06 4.05E+05 8.27E+07 1.56E+06 0.OOE+00 7.79E+05 0.00E+00 1-13.1 7.69E+07 1.08E+08 5.78E+07 3.14E+10 1.85E+08 0.OOE+00 2.13E+07 0.00E+00 1-132 5.20E+01 1.36E+02 4.89E+01 4.59E+03 2.14E+02 0.OOE+00 5.93E+01 0.OOE+00 1-133 1.94E+06 3.29E+06 1.OOE+06 4.59E+08 5.77E+06 0.OOE+00 2.49E+06 0.00E+00 1-134 8.76E-05 2.32E-04 8.34E-05 3.87E-03 3.66E-04 0.OOE+00 3.06E-06 0.OOE+00 1-135 3.53E+04 9.07E+04 3.36E+04 5.84E+06 1.43E+05 0.OOE+00 1.01 E+05 0.OOE+00 Cs-1 34 6.91 E+09 1.63E+10 7.55E+09 0.OOE+00 5.17E+09 1.97E+09 2.02E+08 0.OOE+00 Cs-136 4.28E+07 1.69E+08 1.13E+08 O.OOE+00 9.18E+07 1.45E+07 1.36E+07 0.OOE+00 Cs-1 37 1.06E+10 1.41 E+10 4.90E+09 0.OOE+00 4.79E+09 1.86E+09 2.OOE+08 0.OOE+00 Cs-138 3.64E-11 6.98E-1 I 3.49E-11 0.OOE+00 5.16E- 1 6.OOE-12 3.17E-14 0.OOE+00 Ba-139 2.69E-02 1.90E-05 7.85E-04 0.OOE+00 1.79E-05 1.31 E-05 2.40E-01 0.OOE+00 Ba-140 1.38E+08 1.69E+05 8.89E+06 0.OOE+00 5.73E+04 1.14E+05 2.13E+08 0.OOE+00 Ba-141 4.75E-22 3.55E-25 1.59E-23 0.OOE+00 3.29E-25 2.43E-25 1.01 E-27 0.OOE+00 Ba-142 5.61 E-39 5.61 E-42 3.45E-40 0.OOE+00 4.75E-42 3.74E-42 1.72E-50 0.OOE+00 La-140 1.81 E+03 8.88E+02 2.36E+02 0.OOE+00 0.OOE+00 0.OOE+00 5.10E+07 0.OOE+00 La-142 1.86E-04 8.26E-05 2.06E-05 0.OOE+00 0.OOE+00 0.OOE+00 2.51 E+00 0.OOE+00 Ce-141 2.79E+05 1.86E+05 2.14E+04 0.OOE+00 8.77E+04 0.OOE+00 5.33E+08 O.OOE+00 Ce-143 9.33E+02 6.79E-05 7.58E+01 0.00E+00 3.05E+02 0.OOE+00 2.04E+07 0.00E+00 Ce-144 5.05E+07 2.09E+07 2.71 E+06 0.OOE+00 1.25E+07 0.OOE+00 1.27E+10 0.OOE+00 Pr-143 6.99E+04 2.79E+04 3.48E+03 0.OOE+00 1.62E+04 0.OOE+00 2.30E+08 0.OOE+00 Pr-144 2.93E-26 1.20E-26 1.49E-27 0.OOE+00 6.88E-27 0.OOE+00 3.23E-29 0.OOE+00 Nd-147 2.67E+03 2.90E+03 1.74E+02 0.OOE+00 1.70E+03 0.OOE+00 1.05E+07 0.OOE+00 W-187 3.54E+04 2.89E+04 1.01 E+04 0.OOE+00 0.OOE+00 0.OOE+00 7.81 E+06 0.OOE+00 Np-239 1.39E+03 1.31 E+02 7.26E+01 0.OOE+00 4.1OE+02 0.OOE+00 2.10E+07 0.OOE+00 R VALUES IN UNITS OF MREMYR PER 1iCI/M3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMYR PER jiCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 ffi i ;(ODCM)
MANUAL REV: 17 F Page 113 of 221 Table 5.5-4 R Values for the Prairie Island Nuclear Generating Plant*
- Vegetable, Child PATHWAY = VEGETABLE AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 0.00E+00 4.01 E+03 4.01 E+03 4.01 E+03 4.01 E+03 4.01 E+03 4.01 E+03 4.01 E+03 C-14 5.60E+10 1.12E+10 1.12E+10 1.12E+10 1.12E+10 1.12E+10 1.12E+10 0.OOE+00 Na-24 4.27E+08 4.27E+08 4.27E+08 4.27E+08 4.27E+08 4.27E+08 4.27E+08 0.OOE+00 P-32 3.67E+09 1.72E+08 1.42E+08 0.OOE+00 0.OOE+00 O.OOE+00 1.02E+08 0.00E+00 Cr-51 0.OOE+00 0.OOE+00 1.16E+05 6.43E+04 1.76E+04 I.17E+05 6.14E+06 0.OOE+00 Mn-54 0.OOE+00 6.54E+08 1.74E+08 0.00E+00 1.83E+08 0.00E+00 5.49E+08 0.OOE+00 MN-56 0.OOE+00 1.88E+01 4.20E+00 0.OOE+00 2.28E+01 0.OE+00 2.73E+03 0.OOE+00 Fe-55 7.63E+08 4.05E+08 1.25E+08 0.OOE+00 0.OOE+00 2.29E+08 7.50E+07 0.OOE+00 Fe-59 3.89E+08 6.30E+08 3.14E+08 0.00E+00 0.00E+00 1.83E+08 6.56E+08 0.OOE+00 Co-58 0.OOE+00 6.27E+07 1.92E+08 0.00E+00 0.OOE+00 0.OOE+00 3.66E+08 0.00E+00 Co-60 0.OOE+00 3.77E+08 1.1IE+09 0.00E+00 0.OOE+00 0.OOE+00 2.09E+09 0.OE+00 Ni-63 4.55E+10 2.44E+09 1.55E+09 0.OOE+00 0.OOE+00 0.00E+00 1.64E+08 0.OOE+00 Ni-65 1.05E+02 9.91 E+00 5.79E+00 0.00E+00 0.OOE+00 0.OOE+00 1.21 E+03 0.OOE+00 Cu-64 0.OOE+00 1.13E+04 6.80E+03 0.OOE+00 2.72E+04 0.OOE+00 5.28E+05 0.OOE+00 Zn-65 1.03E+09 2.89E+09 1.70E+09 0.OOE+00 1.72E+09 0.00E+00 4.81 E+08 0.00E+00 Zn-69 9.69E-06 1.40E-05 1.29E-06 0.OOE+00 8.49E-06 0.00E+00 8.83E-04 0.OOE+00 Br-83 0.OOE+00 0.OOE+00 .72E-178 0.OE+00 0.O0E+00 0.00E+00 0.OOE+00 O.OOE+00 Br-84 0.OOE+00 0.0OE+00 3.97E-11 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 Br-85 0.OOE+00 0.O0E+00 I.02E-143 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 Rb-86 0.00E+00 4.55E+08 2.80E+08 0.OOE+00 0.OOE+00 0.OOE+00 2.93E+07 0.00E+00 Rb-88 0.OOE+00 4.43E-22 3.08E-22 0.OOE+00 0.OOE+00 0.OOE+00 2.17E-23 0.OOE+00 Rb-89 0.OOE+00 3.96E-26 3.52E-26 0.OOE+00 0.OOE+00 0.00E+00 3.46E-28 0.OOE+00 Sr-89 3.66E+10 0.OOE+00 1.05E+09 0.OOE+00 0.OOE+00 0.00E+00 1.42E+09 0.00E+00 Sr-90 1.38E+12 0.OOE+00 3.50E+11 0.OOE+00 0.OE+0o 0.00E+00 1.86E+10 0.OOE+00 Sr-91 5.25E+05 0.OOE+00 1.98E+04 0.OOE+00 0.OOE+00 0.00E+00 1.16E+06 0.OOE+00 Sr-92 7.29E+02 0.OOE+00 2.92E+01 0.OOE+00 0.OOE+00 0.OOE+00 1.38E+04 0.OOE+00 Y-90 2.62E+02 0.OOE+00 7.02E+00 0.OOE+00 0.OOE+00 0.OE+00 7.47E+05 0.00E+00 Y-91 M 8.95E-09 0.OOE+0O 4.43E-10 0.OOE+00 0.OOE+00 0.OOE+00 1.75E-05 0.OOE+00 Y-91 1.82E+07 0.OOE+00 4.86E+05 0.00E+00 0.OOE+00 0.00E+00 2.42E+09 0.00E+00 Y-92 8.42E-20 0.OOE+00 2.41 E-21 0.00E+00 0.OOE+00 0.OOE+00 2.43E-15 0.00E+00 Y-93 2.93E+02 0.00E+00 8.05E+00 0.00E+00 0.OOE+00 0.OOE+00 4.37E+06 0.OOE+00 Zr-95 1.52E+05 3.34E+04 2.98E+04 0.OOE+00 4.79E+04 0o0E+00 3.49E+07 0.OOE+00 Zr-97 8.84E-03 1.28E-03 7.54E-04 0.OOE+00 1.83E-03 0.OE+00 1.93E+02 0.OOE+00 Nb-95 4.04E+05 1.57E+05 1.12E+05 0.OOE+00 1.48E+05 0.OOE+00 2.91 E+08 0.OOE+00 Mo-99 O.OOE+OO 9.52E+04 2.36E+04 0.OE+00 2.03E+05 0.OOE+00 7.88E+04 0.OOE+00 Tc-99M 8.63E-12 1.69E-11 2.80E-10 0.OOE+00 2.46E-10 8.59E-12 9.63E-09 0.OOE+00 Tc-101 1.44E-30 1.51 E-30 1.91 E-29 0.00E+00 2.57E-29 7.98E-31 4.80E-30 0.OOE+00 Ru-103 1.52E+07 0.OOE+00 5.84E+06 0.OOE+00 3.82E+07 0.00E+00 3.93E+08 0.OOE+00 Ru-105 9.19E+01 0.OOE+00 3.33E+01 0.OOE+00 8.08E+02 0.OOE+00 6.OOE+04 0.OOE+00 Ru-106 7.52E+08 0.OOE+00 9.38E+07 0.OOE+00 1.02E+09 0.OOE+00 1.17E+10 0.OOE+00 Ag-i1 OM 3.45E+07 2.33E+07 1.86E+07 0.OOE+00 4.34E+07 0.00E+00 2.77E+09 0.OOE+00 Te-125M 4.39E+08 1.19E+08 5.86E+07 1.23E+08 0.OOE+00 0.OOE+00 4.24E+08 0.OOE+00 Te-127M 1.90E+09 5.13E+08 2.26E+08 4.55E+08 5.43E+09 0.OOE+00 1.54E+09 0.OOE+00
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION I H4 MANUAL (ODCM) REV: 17 F Page 114 of 221 Table 5.5-4 R Values for the Prairie Island Nuclear Generating Plant*
- Vegetable, Child PATHWAY = VEGETABLE AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 1.02E+04 2.75E+03 2.19E+03 7.07E+03 2.91 E+04 0.00E+00 3.99E+05 0.OOE+00 Te-129M 9.84E+08 2.75E+08 1.53E+08 3.17E+08 2.89E+09 0.OOE+00 1.20E+09 0.00E+00 Te-129 1.40E-03 3.90E-04 3.32E-04 9.97E-04 4.09E-03 0.OOE+00 8.70E-02 0.00E+00 Te-131M 1.63E+06 5.65E+05 6.01 E+05 1.16E+06 5.47E+06 0.OOE+00 2.29E+07 0.OOE+00 Te-1 31 2.73E-1 5 8.33E-16 8.13E-16 2.09E-1 5 8.26E-15 0.OOE+00 1.43E-14 0.OOE+00 Te-132 7.47E+06 3.31 E+06 4.OOE+06 4.82E+06 3.07E+07 0.OOE+00 3.33E+07 0.OOE+00 1-130 6.15E+05 1.24E+06 6.40E+05 1.37E+08 1.86E+06 0.OOE+00 5.81 E+05 0.OOE+00 1-131 1.43E+08 1.44E+08 8.17E+07 4.76E+10 2.36E+08 0.OOE+00 1.28E+07 0.OOE+00 1-132 9.24E+01 1.70E+02 7.80E+01 7.87E+03 2.60E+02 0.OOE+00 2.OOE+02 0.OOE+00 1-133 3.53E+06 4.37E+06 1.65E+06 8.12E+08 7.28E+06 0.OOE+00 1.76E+06 0.OOE+00 1-134 1.56E-04 2.89E-04 1.33E-04 6.65E-03 4.42E-04 0.OOE+00 1.92E-04 0.OOE+00 1-135 6.26E+04 1.13E+05 5.33E+04 9.98E+06 1.73E+05 0.OOE+00 8.59E+04 0.OOE+00 Cs-134 1.56E+10 2.56E+10 5.41 E+09 0.OOE+00 7.94E+09 2.85E+09 1.38E+08 0.00E+00 Cs-1 36 8.05E+07 2.21 E+08 1.43E+08 0.OOE+00 1.1 8E+08 1.76E+07 7.78E+06 0.00E+00 Cs-137 2.50E+10 2.39E+10 3.53E+09 0.OOE+00 7.79E+09 2.80E+09 1.50E+08 0.OOE+00 Cs-138 6.62E-11 9.20E-11 5.83E-1 I 0.OOE+00 6.47E-11 6.96E-12 4.24E-1 1 0.OOE+00 Ba-139 4.97E-02 2.65E-05 1.44E-03 0.OOE+00 2.32E-05 1.56E-05 2.87E+00 0.OOE+00 Ba-1 40 2.76E+08 2.42E+05 1.61 E+07 0.OOE+00 7.88E+04 1.44E+05 1.40E+08 0.OOE+00 Ba-141 8.76E-22 4.91 E-25 2.85E-23 0.OOE+00 4.24E-25 2.88E-24 4.99E-22 0.OOE+00 Ba-1 42 1.02E-38 7.31 E-42 5.67E-40 0.OOE+00 5.92E-42 4.30E-42 1.32E-40 0.OOE+00 La-140 3.25E+03 1.13E+03 3.54E+02 0.OOE+00 0.OOE+00 0.OOE+00 3.16E+07 0.OOE+00 La-142 3.37E-04 1.07E-04 3.36E-05 0.OOE+00 0.OOE+00 0.OOE+00 2.13E+01 0.OOE+00 Ce-141 6.47E+05 3.23E+05 4.79E+04 0.OOE+00 1.41 E+05 0.OOE+00 4.03E+08 0.OOE+00 Ce-143 1.72E+03 9.31 E+05 1.35E+02 0.OOE+00 3.91 E+02 0.OOE+00 1.36E+07 0.OOE+00 Ce-144 1.22E+08 3.82E+07 6.50E+06 0.OOE+00 2.11 E+07 0.OOE+00 9.95E+09 0.OOE+00 Pr-143 1.45E+05 4.36E+04 7.21 E+03 0.OOE+00 2.36E+04 0.OOE+00 1.57E+08 0.OOE+00 Pr-144 5.44E-26 1.68E-26 2.74E-27 0.OOE+00 8.90E-27 0.OOE+00 3.62E-23 0.OOE+00 Nd-147 4.91 E+03 3.98E+03 3.08E+02 0.OOE+00 2.18E+03 0.OOE+00 6.30E+06 0.OOE+00 W-187 6.44E+04 3.81 E+04 1.71 E+04 0.OOE+00 0.OOE+00 ,0.OOE+00 5.36E+06 0.00E+00 Np-239 2.56E+03 1.84E+02 1.29E+02 0.OOE+00 5.31 E+02 0.OOE+00 1.36E+07 0.00E+00 Co-57 0.OOE+00 2.81 E+05 5.70E+05 0.OOE+00 0.OOE+00 0.OOE+00 2.31 E+06 0.00E+00 Br-82 0.OOE+00 0.OOE+00 3.38E+03 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 Nb-97 3.65E-06 6.59E-07 3.08E-07 0.OOE+00 7.32E-07 O.OOE+00 2.04E-01 0.OOE+00 Sb-124 1.42E+07 1.78E+05 4.82E+06 3.03E+04 0.OOE+00 7.63E+06 8.59E+07 0.00E+00 Sb-125 4.91 E+08 3.79E+06 1.03E+08 4.55E+05 0.00E+00 2.74E+08 1.17E+09 0.00E+00 Sb-126 1.58E+08 2.42E+06 5.69E+07 9.29E+05 0.OOE+00 7.56E+07 3.19E+09 0.OOE+00
- R VALUES IN UNITS OF MREMYR PER iCI/M3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMIYR PER ICI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-5 R Values for the Prairie Island Nuclear Generating Plant*
- Meat, Adult PATHWAY = MEAT AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 O.OOE+00 3.25E+02 3.25E+02 3.25E+02 3.25E+02 3.25E+02 3.25E+02 3.25E+02 C-14 5.38E+09 1.08E+09 1.08E+09 1.08E+09 1.08E+09 1.08E+09 1.08E+09 O.OOE+O0 Na-24 7.88E+07 7.88E+07 7.88E+07 7.88E+07 7.88E+07 7.88E+07 7.88E+07 O.OOE+O P-32 2.29E+09 1.54E+08 8.86E+07 O.OOE+00 O.OOE+OO O.OOE+OO 2.58E+08 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 3.20E+03 1.96E+03 7.21 E+02 4.35E+03 8.24E+05 O.OOE+00 Mn-54 O.OOE+00 4.96E+06 9.46E+05 O.OOE+00 1.47E+06 O.OOE+OO 1.52E+07 O.00E+OO MN-56 O.OOE+0O 7.79E-54 1.38E-54 O.OOE+0O 9.89E-54 O.OOE+0O 2.49E-52 O.00E+OO Fe-55 1.60E+08 1.11E+08 2.58E+07 O.OOE+OO O.OOE+00 6.17E+07 6.34E+07 O.OOE+00 Fe-59 1.25E+08 2.94E+08 1.13E+08 O.OOE+00 O.OOE+OO 8.21 E+07 9.80E+08 O.OOE+00 Co-58 O.OOE+00 8.87E+06 1.99E+07 O.OOE+00 O.OOE+OO 0.OOE+00 1.80E+08 O.OOE+00 Co-60 O.OOE+OO 4.25E+07 9.37E+07 O.OOE+00 O.OOE+OO O.OOE+00 7.98E+08 O.OOE+00 Ni-63 1.18E+10 8.16E+08 3.95E+08 O.OOE+00 O.OOE+OO O.OOE+00 1.70E+08 O.OOE+OO Ni-65 1.16E-52 i.50E-53 6.85E-54 O.OOE+00 O.OOE+00 O.OOE+00 3.81 E-52 O.OOE+OO Cu-64 O.OOE+00 1.69E-07 7.92E-08 O.OOE+00 4.25E-07 O.OOE+OO 1.44E-05 O.OOE+OO Zn-65 2.21 E+08 7.03E+08 3.18E+08 O.OOE+00 4.70E+08 O.OOE+00 4.43E+08 O.OOE+OO Zn-69 9.83E-154 1.88E-153 1.31 E-154 O.OOE+00 1.22E-1 53 O.OOE+00 2.82E-1 54 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO Br-84 O.OOE+00 O.OOE+00 3.82E-270 O.OOE+00 O.OOE+00 O.OOE+00 3.OOE-275 O.OOE+OO Br-85 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 2.30E+08 1.07E+08 b.OOE+00 O.OOE+00 O.OOE+00 4.53E+07 O.OOE+00 Rb-88 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-89 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 1.47E+08 O.OOE+OO 4.21 E+06 O.OOE+00 O.OOE+00 O.OOE+00 2.35E+07 O.OOE+OO Sr-90 7.57E+09 O.OOE+00 1.86E+09 O.OOE+OO 0.OOE+00 O.OOE+0O 2.19E+08 .OOE+bO Sr-91 7.66E-11 O.OOE+O0 3.09E-12 O.OOE+00 O.OOE+00 O.OOE+00 3.65E-10 O.OOE+O Sr-92 6.05E-50 O.OOE+OO 2.62E-51 O.OOE+OO 0.00E+0O O.OOE+00 1.20E-48 O.OOE+00 Y-90 2.86E-19 O.OOE+00 7.67E-21 O.OOE+00 O.OOE+00 O.OOE+00 3.03E-15 O.OOE+00 Y-91M 3.80E-174 O.OOE+00 1.47E-175 O.OOE+OO O.OOE+00 O.OOE+00 1.12E-173 O.OOE+00 Y-91 5.43E+06 O.OOE+00 1 :45E+05 O.OOE+00 O.OOE+OO O.OOE+0O 2.99E+09 O.OOE+OO Y-92 O.OOE+00 O.OOE+00 O.OOE+00 O.00E+OO O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+OO Y-93 2.36E-1 1 0.OOE+0O 6.52E-13 O.OOE+00 O.OOE+OO O.OOE+OO 7.49E-07 O.OOE+OO Zr-95 5.05E+04 1.62E+04 1.iOE+04 O.OOE+00 2.54E+04 O.OOE+O 5.13E+07 O.OOE+00 Zr-97 1.03E-83 2.08E-84 9.50E-85 O.OOE+0O 3.14E-84 O.OOE+0O 6.44E-79 O.OOE+00 Nb-95 1.07E+06 5.96E+05 3.20E+05 O.OOE+00 5.89E+05 O.OOE+00 3.62E+09 O.OOE+00 Mo-99 O.OOE+0O 1.13E-16 2.15E-17 O.OOE+00 2.56E-16 O.OOE+0O 2.62E-16 O.OOE+00 Tc-99M 1.37E-238 3.86E-238 4.91 E-237 O.OOE+0O 5.86E-237 1.89E-238 2.28E-235 O.OOE+00 Tc-101 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 Ru-1 03 4.94E+07 O.OOE+0O 2.13E+07 O.OOE+0O 1.89E+08 O.OOE+00 5.77E+09 O.OOE+OO Ru-105 2.94E-28 O.OOE+00 1.16E-28 O.OOE+OO 3.80E-27 O.OOE+00 1.80E-25 O.OOE+00 Ru-106 1.54E+09 O.OOE+00 1.95E+08 O.OOE+00 2.98E+09 O.OOE+OO 9.99E+10 O.OOE+00 Ag-1I OM 3.76E+06 3.48E+06 2.07E+06 O.OOE+0O 6.84E+06 O.OOE+OO 1.42E+09 O.OOE+OO Te-125M 1.95E+08 7.08E+07 2.62E+07 5.88E+07 7.95E+08 O.OOE+00 7.80E+08 O.OOE+OO Te-127M 7.05E+08 2.52E+08 8.59E+07 1.80E+08 2.86E+09 O.OOE+0O 2.36E+09 O.OOE+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
- ii!OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 116 of 221 Table 5.5-5 R Values for the Prairie Island Nuclear Generating Plant*
- Meat, Adult PATHWAY = MEAT AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I Te-127 8.57E-11 3.08E-11 1.85E- 1 6.35E-1 1 3.49E-10 O.OOE+00 6.76E-09 0.OOE+00 Te-129M 5.71E+08 2.13E+08 9.03E+07 1.96E+08 2.38E+09 O.OOE+00 2.87E+09 0.OOE+00 Te-129 2.42E-121 9.09E-122 5.89E-1 22 1.86E-121 1.02E-120 O.OOE+00 1.83E-121 0.OOE+00 Te-131M 2.31E+02 1.13E+02 9.40E+01 1.79E+02 1.14E+03 O.OOE+00 1.12E+04 0.OOE+00 Te-131 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Te-132 7.28E+05 4.71 E+05 4.42E+05 5.20E+05 4.53E+06 O.OOE+00 2.23E+07 0.OOE+00 1-130 1.04E-06 3.06E-06 1.21E-06 2.59E-04 4.77E-06 O.OOE+00 2.63E-06 0.OOE+00 1-131 5.28E+06 7.55E+06 4.33E+06 2.48E+09 1.29E+07 O.OOE+00 1.99E+06 0.OOE+00 1-132 3.59E-59 9.61 E-59 3.36E-59 3.36E-57 1.53E-58 O.OOE+00 1.81E-59 0.OOE+00 1-133 1.83E-01 3.19E-01 9.72E-02 4.68E+01 5.56E-01 O.OOE+00 2.87E-01 0.OOE+00 1-134 5.77E-162 1.57E-161 5.60E-162 2.72E-160 2.49E-161 O.OOE+00 1.37E-1 64 0.OOE+00 1-135 2.24E-17 5.86E-17 2.16E-17 3.86E-1 5 9.39E-17 O.OOE+00 6.62E-17 0.00E+00 Cs-134 3.62E+08 8.61E+08 7.04E+08 O.OOE+00 2.79E+08 9.26E+07 1.51 E+07 0.OOE+00 Cs-I 36 5.66E+06 2.23E+07 1.61E+07 O.OOE+00 1.24E+07 1.70E+06 2.54E+06 0.OOE+00 Cs-1 37 5.10E+08 6.98E+08 4.57E+08 O.OOE+00 2.37E+08 7.88E+07 1.35E+07 0.OOE+00 Cs-138 1.53E-267 3.03E-267 1.50E-267 O.OOE+00 2.22E-267 2.20E-268 1.29E-272 0.OE+00 Ba-139 6.54E-102 4.66E-105 1.92E-103 O.OOE+00 4.36E-105 2.64E-1 05 1.16E-101 0.OOE+00 Ba-140 1.38E+07 1.73E+04 9.02E+05 O.OOE+00 5.88E+03 9.90E+03 2.84E+07 0.OOE+00 Ba-141 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Ba-142 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 La-140 1.86E-02 9.36E-03 2.47E-03 O.OOE+00 O.OOE+00 O.OOE+00 6.87E+02 0.OOE+00 La-142 1.80E-92 8.19E-93 2.04E-93 O.OOE+00 O.OOE+00 O.OOE+00 5.98E-89 0.OOE+00 Ce-141 6.54E+03 4.42E+03 5.02E+02 O.OOE+00 2.05E+03 O.OOE+00 1.69E+07 0.OOE+00 Ce-143 1.01 E-02 7.44E+00 8.23E-04 O.OOE+00 3.27E-03 O.OOE+00 2.78E+02 0.OOE+00 Ce-144 7.72E+05 3.23E+05 4.14E+04 O.OOE+00 1.91 E+05 O.OOE+00 2.61 E+08 0.OOE+00 Pr-143 1.00E+04 4.01 E+03 4.96E+02 O.OOE+00 2.32E+03 O.OOE+00 4.38E+07 0.OOE+00 Pr-144 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Nd-147 6.72E-03 7.77E-03 4.65E-04 O.OOE+00 4.54E-03 O.OOE+00 3.73E+01 0.OOE+00 W-187 1.04E-02 8.67E-03 3.03E-03 O.OOE+00 O.OOE+00 O.OOE+00 2.84E+00 0.OOE+00 Np-239 1.30E-01 1.28E-02 7.03E-03 O.OOE+00 3.98E-02 O.OOE+00 2.62E+03 0.OOE+00 R VALUES IN UNITS OF MREM/YR PER jlCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREM/YR PER lCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-6 R Values for the Prairie Island Nuclear Generating Plant*
- Meat, Teen PATHWAY = MEAT AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 0.00E+00 1.94E+02 1.94E+02 1.94E+02 1.94E+02 1.94E+02 1.94E+02 1.94E+02 C-14 4.54E+09 9.08E+08 9.08E+08 9.08E+08 9.08E+08 9.08E+08 9.08E+08 0.00E+00 Na-24 6.30E+07 6.30E+07 6.30E+07 6.30E+07 6.30E+07 6.30E+07 6.30E+07 0.00E+00 P-32 1.94E+09 1.20E+08 7.51 E+07 0.OOE+00 0.OOE+00 0.OOE+00 1.63E+08 0.00E+00 Cr-51 0.00E+00 0.00E+00 2.62E+03 1.46E+03 5.74E+02 3.74E+03 4.40E+05 0.00E+00 Mn-54 0.OOE+00 3.78E+06 7.50E+05 0.OOE+00 1.13E+06 0.00E+00 7.75E+06 0.00E+00 MN-56 0.OOE+00 6.33E-53 1.13E-54 0.00E+00 8.01 E-54 0.00E+00 4.16E-52 0.00E+00 Fe-55 1.30E+08 9.22E+07 2.15E+07 0.OE+00 0.OOE+00 5.85E+07 3.99E+07 0.00E+00 Fe-59 1.OOE+08 2.33E+08 9.01 E+07 0.OOE+00 0.00E+00 7.36E+07 5.52E+08 0.00E+00 Co-58 0.OOE+00 6.84E+06 1.58E+07 0.OOE+00 0.00E+00 0.OOE+00 9.43E+07 0.OOE+00 Co-60 0.00E+00 3.30E+07 7.42E+07 0.00E+00 0.OOE+00 0.00E+00 4.29E+08. 0.00E+00 Ni-63 9.47E+09 6.69E+08 3.21 E+08 0.OOE+00 0.00E+00 0.OOE+00 1.06E+08 0.00E+00 Ni-65 9.69E-53 1.24E-53 5.64E-54 0.OOE+00 0.OOE+00 0.00E+00 6.71 E-52 0.00E+00 Cu-64 0.OOE+00 1.38E-07 6.47E-08 0.OOE+00 3.48E-07 0.OOE+00 1.07E-05 0.00E+00 Zn-65 1.55E+08 5.40E+08 2.52E+08 0.00E+00 3.45E+05 0.OOE+00 2.29E+08 0.00E+00 Zn-69 8.29E-154 1.58E-153 .11E-154 0.OOE+00 1.03E-153 0.OOE+00 2.91 E-153 0.00E+00 Br-83 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Br-84 0.OOE+00 0.OOE+00 3.13E-270 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 Br-85 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 Rb-86 0.OOE+00 1.92E+08 9.OOE+07 0.OOE+00 0.OOE+00 0.OOE+00 2.84E+07 0.OOE+00 Rb-88 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Rb-89 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 Sr-89 1.24E+08 0.00E+00 3.55E+06 0.OOE+00 0.00E+00 0.00E+00 1.47E+07 0.00E+00 Sr-90 4.90E+09 0.OOE+00 1.21 E+09 0.00E+00 0.OOE+00 0.OOE+00 1.37E+08 0.00E+00 Sr-91 6.44E-11 0.00E+00 2.56E-12 0.00E+00 0.OOE+00 0.00E+00 2.92E-10 0.00E+00 Sr-92 5.07E-50 0.OOE+00 2.16E-51 0.OOE+00 0.OOE+00 0.00E+00 1.29E-48 0.00E+00 Y-90 2.41 E-19 0.00E+00 6.48E-21 0.OOE+00 0.OOE+00 0.OOE+00 1.98E-15 0.00E+00 Y-91M 3.19E-174 0.00E+00 I.22E-175 0.OOE+00 0.OOE+00 0.OOE+00 1.50E-1 72 0.00E+00 Y-91 4.57E+06 0.00E+00 1.23E+05 0.OOE+00 0.00E+00 0.OOE+00 1.87E+09 0.00E+00 Y-92 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 Y-93 1.99E-11 0.OOE+00 5.47E-13 0.ooE+00 0.OOE+00 0.00E+00 6.09E-07 0.00E+00 Zr-95 4.04E+04 1.28E+04 8.77E+03 0.00E+00 1.87E+04 0.00E+00 2.94E+07 0.00E+00 Zr-97 8.59E-84 1.70E-84 7.83E-85 0.00E+00 2.58E-84 0.OOE+00 4.60E-79 0.00E+00 Nb-95 8.36E+05 4.64E+05 2.55E+05 0.OOE+00 4.50E+05 0.OOE+00 1.98E+09 0.OOE+00 Mo-99 0.OE+00 9.34E-17 1.78E-17 0.OOE+00 2.14E-16 0.OOE+00 1.67E-16 0.00E+00 Tc-99M 1.08E-238 3.03E-238 3.92E-237 0.00E+00 4.51 E-237 1.68E-238 1.99E-235 0.OOE+00 Tc-101 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 Ru-1 03 4.03E+07 0.OOE+00 1.72E+07 0.OOE+00 1.42E+08 0.OOE+00 3.36E+09 0.00E+00 K<' Ru-105 2.46E-28 0.00E+00 9.53E-29 0.00E+00 3.1 OE-27 0.00E+00 1.98E-25 0.00E+00 Ru-1 06 1.30E+09 0.OOE+00 1.64E+08 0.OOE+00 2.51 E+09 0.OOE+00 6.23E+10 0.00E+00 Ag-1OM 2.85E+06 2.69E+06 1.64E+06 0.OOE+00 5.14E+06 0.00E+00 7.57E+08 0.00E+00 Te-125M 1.65E+08 5.94E+07 2.21 E+07 4.61 E+07 0.00E+00 0.00E+00 4.87E+08 0.OOE+00 Te-1 27M 5.95E+08 2. IE+08 7.07E+07 1.41 E+08 2.41 E+09 0.00E+00 1.48E+09 0.00E+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM). REV: 17 F Page 118 of 221 Table 5.5-6 R Values for the Prairie Island Nuclear Generating Plant*
- Meat, Teen PATHWAY = MEAT AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I Te-127 7.27E-11 2.58E-11 1.56E-11 5.02 E-11 2.95E-10 O.OOE+00 5.62E-09 O.OOE+00 Te-129M 4.78E+08 1.77E+08 7.57E+07 1.54E+08 2.00E+09 O.OOE+00 1.79E+09 O.OOE+00 Te-129 2.04E-121 7.60E-122 4.96E-122 1.46E-121 8.56E-121 O.OOE+00 1.12E-120 O.OOE+00 Te-131 M 1.92E+02 9.22E+01 7.69E+01 1.39E+02 9.62E+02 O.OOE+00 7.40E+03 O.OOE+00 Te-1 31 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 Te-132 5.96E+05 3.77E+05 3.52E+05 3.98E+05 3.62E+06 O.OOE+00 1.19E+07 O.OOE+00 1-130 8.35E-07 2.42E-06 9.64E-07 1.97E-04 3.72E-06 O.OOE+00 1.86E-06 O.OOE+00 1-131 4.39E+06 6.14E+06 3.30E+06 1.79E+09 1.06E+07 O.OOE+00 1.22E+06 O.OOE+00 1-132 2.92E-59 7.64E-59 2.74E-59 2.57E-57 1.20E-58 O.OOE+00 3.33E-59 O.OOE+00 1-133 1.53E-01 2.60E-01 7.93E-02 3.63E+01 4.56E-01 O.OOE+00 1.97E-01 O.OOE+00 1-134 4.69E-162 1.24E-161 4.47E-162 2.07E-1 60 1.96E-161 O.OOE+00 1.64E-163 O.OOE+00 1-135 1.82E-17 4.69E-17 1.74E-17 3.01 E-15 7.40E-17 O.OOE+00 5.19E-17 O.OOE+00 Cs-134 2.88E+08 6.78E+08 3.14E+08 0.OOE+00 2.15E+08 8.22E+07 8.43E+06 O.OOE+00 Cs-I 36 4.41 E+06 1.74E+07 1.17E+07 0.00E+00 9.45E+06 1.49E+06 1.40E+06 O.OOE+00 Cs-1 37 4.24E+08 5.64E+08 1.96E+08 0.OOE+00 1.92E+08 7.46E+07 8.02E+06 O.OOE+00 Cs-138 1.27E-267 2.44E-267 1.22E-267 0.OOE+00 1.80E-267 2.1 OE-268 1.11 E-270 O.OOE+00 Ba-139 5.54E-102 3.90E-105 1.61 E-1 03 0.OOE+00 3.68E-105 2.69E-105 4.94E-101 O.OOE+00 Ba-140 1.14E+07 1.39E+04 7.34E+05 0.OOE+00 4.73E+03 9.38E+03 1.76E+07 O.OOE+00 Ba-141 O.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ba-142 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 La-140 1.53E-02 7.51 E-03 2.OOE-03 0.OOE+00 O.OOE+00 O.OOE+00 4.31 E+02 O.OOE+00 La-1 42 1.49E-92 6.61 E-93 1.65E-93 0.OOE+00 O.OOE+00 O.OOE+00 2.01 E-88 O.OOE+00 Ce-141 5.49E+03 3.67E+03 4.21 E+02 0.OOE+00 1.73E+03 O.OOE+00 1.05E+07 O.OOE+00 Ce-143 8.47E-03 6.16E+00 6.88E-04 0.OOE+00 2.76E-03 O.OOE+00 1.85E+02 O.OOE+00 Ce-144 6.51 E+05 2.69E+05 3.50E+04 0.OOE+00 1.61 E+05 O.OOE+00 1.64E+08 O.OOE+00 Pr-143 8.42E+03 3.36E+03 4.19E+02 0.OOE+00 1.95E+03 O.OOE+00 2.77E+07 O.OOE+00 Pr-144 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Nd-147 5.92E-03 6.44E-03 3.86E-04 0.OOE+00 3.78E-03 O.OOE+00 2.32E+01 O.OOE+00 W-187 8.69E-03 7.08E-03 2.48E-03 0.OOE+00 O.OOE+00 O.OOE+00 1.92E+00 O.OOE+00 Np-239 1.13E-01 1.07E-02 5.94E-03 0.OOE+00 3.36E-02 O.OOE+00 1.72E+03 0.OOE+00
- R VALUES IN UNITS OF MREMNR PER gCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMIYR PER iCI/SEC FOR ALL OTHERS.
PRAJRIE ISLAND NUCLEAR GENERATING PLANT HPROCEDURE Table 5.5-7 R Values for the Prairie Island Nuclear Generating Plant*
- Meat, Child PATHWAY = MEAT AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 O.OOE+00 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 C-14 8.54E+09 1.71 E+09 1.71 E+09 1.71 E+09 1.71 E+09 1.71 E+09 1.71 E+09 O.OOE+00 Na-24 1.OOE+08 I.OOE+08 1.OOE+08 1.OOE+08 1.OOE+08 1.OOE+08 1.OOE+08 O.OOE+00 P-32 3.65E+09 1.71 E+08 1.41 E+08 O.OOE+00 O.OOE+00 O.OOE+OO 1.01E+08 O.OOE+00 Cr-51 O.OOE+0 O.OOE+00 4.08E+03 2.27E+03 6.20E+02 4.14E+03 2.17E+05 O.OOE+00 Mn-54 O.OOE+00 4.33E+06 1.1 5E+06 O.OOE+00 1.21 E+06 O.OOE+00 3.63E+06 O.OOE+00 MN-56 O.OOE+00 8.44E-54 1.88E-54 O.OOE+00 1.02E-53 O.OOE+00 1.22E-51 O.OOE+00 Fe-55 2.49E+08 1.32E+08 4.1OE+07 O.OOE+00 O.OOE+00 7.48E+07 2.45E+07 O.OOE+00 Fe-59 1.77E+08 2.87E+08 1.43E+08 O.OOE+00 O.OOE+00 8.32E+07 2.99E+08 O.OOE+00 Co-58 0.OOE+00 7.99E+06 2.44E+07 O.OOE+00 O.OOE+00 O.OOE+00 4.66E+07 O.OOE+00 Co-60 O.OOE+00 3.91 E+07 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 2.17E+08 O.OOE+00 Ni-63 1.82E+10 9.72E+08 6.18E+08 O.OOE+00 O.OOE+00 O.OOE+00 6.55E+07 O.OOE+00 Ni-65 1.81 E-52 1.70E-53 9.95E-54 O.OOE+OO O.OOE+OO O.OOE+00 2.09E-51 O.OOE+00 Cu-64 O.OOE+OO ,1.85E-07 1.12 E-07. O.OOE+00 4.47E-07 O.OOE+00 8.68E-06 O.OOE+00 Zn-65 2.33E+08 6.55E+08 3.86E+08 O.OOE+00 3.91 E+08 O.OOE+00 1.09E+08 O.OOE+00 Zn-69 1.56E-153 2.25E-1 53 2.08E-154 O.OOE+00 1.37E-153 O.OOE00 1.42E-151 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 5.42E-270 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+OO 2.72E+08 1.67E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.75E+07 0.00E+00 Rb-88 O.OOE+00 b.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 Rb-89 O.OOE+00 0.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Sr-89 2.34E+08 O.OOE+00 6.69E+06 O.OOE+00 O.OOE+00 O.OOE+00 9.07E+06 O.OOE+00 Sr-90 6.33E+09 0.00+00 1.60E+09 O.OOE+OO 0.OOE+00 O.OOE+00 8.52E+07 O.OOE+00 Sr-91 1.21 E-10 b.OOE+OO 4.56E-12 O.OOE+00 O.OOE+00 O.OOE+00 2.67E-10 O.OOE+00 Sr-92 9.47E-50 O.OOE+00 3.80E-51 O.OOE+00 O.OOE+00 O.OOE+00 .1.79E-48 O.OOE+00 Y-90 4.55E-19 O.OOE+00 1.22E-20 O.OOE+00 O.OOE+00 O.OOE+00 1.30E-15 O.OOE+00 Y-91M 5.95E-174 0.00E+O 2.94E-1 75 O.OOE+00 O.OOE+00 O.OOE+00 1.17E-170 O.OOE+00 Y-91 8.64F+06 O.OOE+00 2.31 E+05 O.OOE+00 O.OOE+OO O.OOE+00 1.15E+09 O.OOE+00 Y-92 O.OOE+OO O.OOE+00 O.OOE+00 'O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-93 3.75E-11 O.OOE+OO 1.03E-12 O.OOE+O0 O.OOE+00 O.OOE+00 5.58E-07 O.OOE+00 Zr-95 7.18E+04 1.58E+04 1.40E+04 O.OOE+00 2.26E+04 O.OOE+00 1.65E+07 O.OOE+00 Zr-97 1.60E-83 2.31 E-84 1.36E-84 O.OOE+00 3.31 E-84 O.OOE+00 3.50E-79 O.OOE+00 Nb-95 1.44E+06 5.62E+05 4.02E+05 O.OOE+00 5.28E+05 O.OOE+00 1.04E+09 O.OOE+00 Mo-99 O.OOE+00 1.30E-16 3.22E-17 O.OOE+00 2.78E-16 O.OOE+00 1.07E-16 O.OOE+00 Tc-99M 1.90E-238 3.73E-238 6.18E-237 O.OOE+00 5.42E-237 1.89E-238 2.12E-235 O.OOE+00 Tc-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ru-103 7.28E+07 O.OOE+00 2.80E+07 O.OOE+00 1.83E+08 O.OOE+00 1.88E+09 O.OOE+00 K~' Ru-105 4.58E-28 O.OOE+00 1.66E-28 O.OOE+00 4.03E-27 O.OOE+00 2.99E-25 O.OOE+00 Ru-106 2.45E+09 O.OOE+00 3.05E+08 O.OOE+00 3.30E+09 O.OOE+00 3.81 E+10 O.OOE+00 Ag-1 OM 4.72E+06 3.19E+06 2.55E+06 O.OOE+00 5.94E+06 O.OOE+00 3.79E+08 O.OOE+00 Te-125M 3.1 OE+08 8.40E+07 4.13E+07 8.69E+07 O.OOE+00 O.OOE+00 2.99E+08 O.OOE+00 Te-127M 1.1 2E+09 3.02E+08 1.33E+08 2.68E+08 3.20E+09 O.OOE+00 9.08E+08 O.OOE+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 6 E m (ODCM)
MANUAL REV: 17 F5, .Page 120 of 221 Table 5.5-7 R Values for the Prairie Island Nuclear Generating Plant*
- Meat, Child PATHWAY = MEAT AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-1 27 1.37E-10 3.69E-11 2.93E-1 I 9.46E-1 I 3.89E-1 0 0.OOE+00 5.34E-09 0.00E+00 Te-129M 9.01 E+08 2.52E+08 1.40E+08 2.90E+08 2.64E+09 0.OOE+00 1.10E+09 0.OOE+00 Te-129 3.85E-121 1.07E-121 9.13E-122 2.74E-121 1.13E-120 0.00E+00 2.39E-119 0.00E+00 Te-131 M 3.58E+02 1.24E+02 1.32E+02 2.55E+02 1.20E+03 0.OOE+00 5.02E+03 0.00E+00 Te-131 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Te-132 1.09E+06 4.81 E+05 5.81 E+05 7.01 E+05 4.47E+06 0.OOE+00 4.84E+06 0.OOE+00 1-130 1.49E-06 3.02E-06 1.55E-06 3.32E-04 4.51 E-06 0.OOE+00 1.41 E-06 0.OOE+00 1-131 8.14E+06 8.19E+06 4.65E+06 2.71 E+09 1.34E+07 0.OOE+00 7.29E+05 0.OE+00 1-132 5.28E-59 9.70E-59 4.46E-59 4.50E-57 1.48E-58 0.00E+00 1.14E-58 0.OOE+00 1-133 2.85E-01 3.52E-01 1.33E-01 6.54E+01 5.87E-01 0.OOE+00 1.42E-01 0.OOE+00 1-134 8.50E-162 1.58E-161 7.26E-162 3.63E-160 2.41 E-1 61 0.OOE+00 1.05E-161 0.OOE+00 1-135 3.29E:17 5.93E-17 2.80E-17 5.25E-1 5 9.09E-17 0.OOE+00 4.52E-17 0.OOE+00 Cs-134 5.08E+08 8.33E+08 1.76E+08 0.OOE+00 2.58E+08 9.26E+07 4.49E+06 0.OOE+00 Cs-136 7.62E+06 2.09E+07 1.35E+07 0.OOE+00 1.1 E+07 1.66E+06 7.36E+05 0.OOE+00 Cs-137 7.81 E+08 7.47E+08 1.10E+08 0.OOE+00 2.43E+08 8.76E+07 4.68E+06 0.00E+00 Cs-1 38 2.36E-267 3.28E-267 2.08E-267 0.OOE+00 2.31 E-267 2.48E-268 1.51 E-267 0.00E+00 Ba-1 39 1.04E-101 5.56E-105 3.02E-103 0.OOE+00 4.85E-1 05 3.27E-1 05 6.01 E-100 0.OOE+00 Ba-1 40 2.1OE+07 1.84E+04 1.23E+06 0.OOE+00 5.99E+03 1.10E+04 1.06E+07 0.OOE+00 Ba-141 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Ba-i 42 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 La-140 2.80E-02 9.77E-03 3.05E-03 0.OOE+00 0.OOE+00 0.OOE+00 2.72E+02 0.OOE+00 La-142 2.75E-92 8.76E-93 2.74E-93 0.OOE+00 0.OOE+00 0.OOE+00 1.74E-87 0.OOE+00 Ce-141 1.03E+04 5.16E+03 7.66E+02 0.OOE+00 2.26E+03 0.OOE+00 6.43E+06 0.OOE+00 Ce-143 1.59E-02 8.61 E+00 1.25E-03 0.OOE+00 3.61 E-03 0.OOE+00 1.26E+02 0.0OE+00 Ce-1 44 1.23E+06 3.84E+05 6.55E+04 0.OOE+00 2.13E+05 0.OOE+00 1.OOE+08 0.OOE+00 Pr-143 1.59E+04 4.79E+03 7.91 E+02 0.OOE+00 2.59E+03 0.OOE+00 1.72E+07 0.OOE+00 Pr-144 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00
- Nd-147 1.11 E-02 9.OOE-03 6.97E-04 0.OOE+00 4.94E-03 0.OOE+00 1.43E+01 0.OOE+00 W-187 1.61 E-02 9.53E-03 4.28E-03 0.OOE+00 0.OOE+00 0.OOE+00 1.34E+00 0.00E+00 Np-239 2.13E-01 1.53E-02 1.08E-02 0.OOE+00 4.43E-02 0.OOE+00 1.13E+03 0.OOE+00 R VALUES IN UNITS OF MREMYR PER CI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMNR PER pCIISEC FOR ALL OTHERS.
'j
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE:
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) .. REV. 17
~
___________________ ~ ~ ~ ~ ~ ~ ~ F Page 12I f 2 Table 5.5-8 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Adult PATHWAY = COW MILK AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 O.OOE+00 7.63E+02 7.63E+02 7.63E+02 7.63E+02 7.63E+02 7.63E+02 7.63E+02 C-14 5.87E+09 1.17E+09 1.17E+09 1.17E+09 1.17E+09 1.17E+09 I.17E+09 O.OOE+OO Na-24 3.01 E+08 3.01 E+08 3.01 E+08 3.01 E+08 3.01 E+08 3.01 E+08 3.01 E+08 O.OOE+0O P-32 8.41 E+09 5.67E+08 3.25E+08 O.OOE+OO O.OOE+OO O.OOE+00 9.46E+08 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 1.30E+04 7.94E+03 2.93E+03 1.76E+04 3.34E+06 O.OOE+OO Mn-54 O.OOE+00 4.54E+06 8.67E+05 O.OOE+OO 1.35E+06 O.OOE+00 1.39E+07 O.OOE+OO MN-56 O.OOE+00 2.08E-03 3.69E-04 O.OOE+00 2.64E-03 O.OOE+00 6.65E-02 O.OOE+OO Fe-55 1.37E+07 9.47E+06 2.21 E+06 00OOE+00 O.OOE+0O 5.28E+06 5.43E+06 O.OOE+00 Fe-59 1.40E+07 3.29E+07 1.26E+07 O.OOE+0O O.OOE+0O 9.19E+06 1.1OE+08 O.OOE+OO Co-58 O.OOE+00 2.29E+06 5.14E+06 O.OOE+OO O.OOE+00 O.OOE+OO 4.65E+07 O.OOE+O0 Co-60 O.OOE+00 9.27E+06 2.04E+07 O.OOE+00 O.OOE+OO O.OOE+0O 1.74E+08 O.OOE+00 Ni-63 4.20E+09 2.91 E+08 1.41 E+08 O.OOE+00 O.OOE+0O O.OOE+OO 6.07E+07 O.OOE+OO Ni-65 1.86E-01 2.41 E-02 1.1OE-02 O.OOE+00 O.OOE+00 O.OOE+OO 6.11E-01 O.OOE+OO Cu-64 O.OOE+0O 1.23E+04 5.77E+03 O.OOE+00 3.1 OE+04 O.OOE+0O 1.05E+06 O.OOE+00 Zn-65 8.52E+08 2.71 E+09 1.23E+09 O.OOE+00 1.81 E+09 O.OOE+00 1.71 E+09 O.OOE+00 Zn-69 I1.06E-12 2.03E-12 1.41 E-13 O.OOE+00 1.32E-12 O.OOE+00 3.05E-13 O.OOE+00 Br-83 O.OOE+00 O.OOE+OO O.OOE+0O O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 Br-84 O.OOE+OO O.OOE+00 8.24E-24 O.OOE+0O O.OOE+00 b.OOE+OO 6.47E-29 O.OOE+00 Br-85 O.00E+OO O.OOE+00 3.40E-288 O.OOE+0O O.OOE+00 O.OOE+OO O.OOE+OO 0.OOE+OO Rb-86 O.O0E+OO 1.22E+09 5.70E+08 O.OOE+0O 0.OOE+OO O.OOE+00 2.41 E+08 O.OOE+0O Rb-88 O.0OE+OO 1.09E-45 5.76E-46 O.OOE+OO 0.OOE+OO O.OOE+OO 1.50E-56 O.OOE+00 Rb-89 O.OOE+00 1.59E-53 1.12E-53 O.OOE+OO O.OOE+00 O.OOE+00 9.23E-67 O.OOE+0O Sr-89 6.99E+08 O.OOE+00 2.OOE+07 O.OOE+OO O.OOE+00 O.OOE+OO 1.12E+08 O.OOE+0O Sr-90 2.85E+10 O.OOE+00 6.99E+09 O.OOE+OO O.OOE+00 O.OOE+00 8.22E+08 O.OOE+0O Sr-91 1.45E+04 O.OOE+00 5.85E+02 O.OOE+00 O.OOE+OO O.OOE+OO 6.90E+04 O.OOE+00 Sr-92 2.45E-01 O.OOE+OO 1.06E-02 O.OOE+00 O.OOE+0O O.OOE+O0 4.85E+00 O.OOE+OO Y-90 3.82E-02 0.OOE+OO 1.02E-03 O.OOE+00 O.OOE+0O O.OOE+OO 4.05E+02 O.OOE+OO Y-91M 3.02E-20 O.OOE+00 1.17E-21 O.OOE+0O O.OOE+0O O.OOE+0O 8.86E-20 O.OOE+OO Y-91 4.12E+03 O.OOE+00 1.1OE+02 O.OOE+0O O.OOE+OO O.OOE+0O 2.27E+06 O.OOE+0O Y-92 4.79E-43 O.OOE+00 1.40E-44 O.OOE+OO O.OOE+OO O.OOE+00 8.38E-39 O.OOE+0O Y-93 1.12E-01 -O.OOE+OO 3.09E-03 O.OOE+OO O.OOE+00 O.OOE+OO 3.55E+03 O.OOE+00 Zr-95 1.47E+02 4.72E+01 3.19E+01 O.OOE+0O 7.40E+01 O.OOE+00 1.50E+05 O.OOE+0O Zr-97 4.50E-1 0 9.07E-1 I 4.15E-11 O.OOE+00 1.37E-1 0 O.OOE+OO 2.81 E-05 O.OOE+OO Nb-95 3.85E+04 2.14E+04 1.15E+04 O.OOE+00 2.12E+04 O.OOE+00 1.30E+08 0.OOE+0O Mo-99 O.OOE+00 1.55E+04 2.96E+03 O.OOE+00 3.52E+04 O.OOE+00 3.60E+04 O.OOE+00 Tc-99M 4.04E-23 1.14E-22 1.46E-21 O.OOE+0O 1.74E-21 5.60E-23 6.76E-20 O.OOE+0O Tc-101 1.34E-60 1.93E-60 1.89E-59 O.OOE+00 3.48E-59 9.87E-61 5.81 E-72 O.OOE+OO Ru-103 4.79E+02 O.OOE+00 2.06E+02 O.00E+0O 1.83E+03 O.OOE+OO 5.59E+04 .OOE+0O Ru-1 05 4.29E-04 O.OOE+OO 1.70E-04 O.OOE+00 5.55E-03 O.OOE+0O 2.63E-01 O.OOE+0O Ru-1 06 1.12E+04 O.OOE+00 1.42E+03 O.OOE+0O 2.17E+04 O.OOE+OO 7.28E+05 O.OOE+00 Ag-110M 3.28E+07 3.03E+07 1.80E+07 O.OOE+0O 5.96E+07 O.OOE+OO 1.24E+10 O.OOE+0O Te-125M 8.87E+06 3.21 E+06 1.19E+06 2.67E+06 3.61 E+07 O.OOE+00 3.54E+07 O.OOE+00 Te-1 27M 2.89E+07 1.03E+07 3.53E+06 7.39E+06 1.18E+08 O.OOE+0O 9.70E+07 O.OOE+0O
PRAIRIE ISLAND NUCLEAR GENERATING PLANT - H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 l t ! (ODCM)
MANUAL REV: 17 Page 122 of 221 Table 5.5-8 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Adult PATHWAY = COW MILK AGE GROUP = ADULT NUCLIDE BONE Li' IER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 3.23E+02 1.16E+02 7.00E+01 2.40E+02 1.32E+03 0.00E+00 2.55E+04 O.OOE+00 Te-129M 3.03E+07 1.13E+07 4.79E+06 1.04E+07 1.26E+08 0.00E+00 1.52E+08 0.00E+00 Te-129 1.45E-10 5.44E-11 3.53E-11 1.11E-10 6.09E-10 0.00E+00 1.09E-10 0.00E+00 Te-131M 1.84E+05 9.01 E+04 7.51 E+04 1.43E+05 9.13E+05 0.00E+00 8.95E+06 0.00E+00 Te-131 1.87E-33 7.80E-34 5.90E-34 1.54E-33 8.18E-33 0.00E+00 2.64E-34 0.00E+00 Te-132 1.23E+06 7.95E+05 7.46E+05 8.78E+05 7.66E+06 0.00E+00 3.76E+07 0.OOE+00 1-130 2.10E+05 6.18E+05 2.44E+05 5.24E+07 9.65E+05 0.00E+00 5.32E+05 0.00E+00 1-131 1.46E+08 2.08E+08 1.19E+08 6.82E+10 3.57E+08 0.00E+00 5.49E+07 0.OOE+00 1-132 8.24E-02 2.20E-01 7.71 E-02 7.71 E+00 3.51 E-01 0.00E+00 4.14E-02 0.00E+00 1-133 1.94E+06 3.37E+06 1.03E+06 4.95E+08 5.88E+06 0.00E+00 3.03E+06 0.OOE+00 1-134 1.02E-12 2.76E-12 9.88E-13 4.79E-11 4.39E-12 0.00E+00 2.41 E-15 0.OOE+00 1-135 6.43E+03 1.68E+04 6.21 E+03 1.11E+06 2.70E+04 0.00E+00 1.90E+04 0.OOE+00 Cs-134 3.11 E+09 7.41 E+09 6.05E+09 0.00E+00 2.40E+09 7.96E+08 1.30E+08 0.OOE+00 Cs-I 36 1.25E+08 4.94E+08 3.55E+08 0.00E+00 2.75E+08 3.77E+07 5.61 E+07 0.OOE+00 Cs-137 4.32E+09 5.91 E+09 3.87E+09 0.00E+00 2.01 E+09 6.67E+08 1.14E+08 0.00E+00 Cs-1 38 4.58E-24 9.05E-24 4.48E-24 0.00E+00 6.65E-24 6.57E-25 3.86E-29 0.OOE+00 Ba-1 39 2.22E-08 1.58E-11 6.50E-10 0.00E+00 1.48E-11 8.98E-12 3.94E-08 0.00E+00 Ba-1 40 1.29E+07 1.62E+04 8.44E+05 0.00E+00 5.50E+03 9.26E+03 2.65E+07 0.OOE+00 Ba-141 4.00E-47 3.03E-50 1.35E-48 0.00E+00 2.81 E-50 1.72E-50 1.89E-56 0.OOE+00 Ba-142 1.38E-80 1.42E-83 8.70E-82 0.00E+00 1.20E-83 8.05E-84 1.95E-98 0.00E+00 La-140 2.26E+00 1.14E+00 3.01E-01 0.00E+00 0.00E+00 0.00E+00 8.35E+04 0.OOE+00 La-142 9.33E-12 4.24E-12 1.06E-12 0.00E+00 0.00E+00 0.00E+00 3.1 OE-08 0.OOE+00 Ce-1 41 2.26E+03 1.53E+03 1.73E+02 0.00E+00 7.08E+02 0.00E+00 5.83E+06 0.00E+00 Ce-143 2.08E+01 1.54E+04 1.70E+00 0.00E+00 6.77E+00 0.00E+00 5.75E+05 0.00E+00 Ce-1 44 1.89E+05 7.92E+04 1.02E+04 0.OOE+00 4.70E+04 0.00E+00 6.41 E+07 0.00E+00 Pr-143 7.54E+01 3.02E+01 3.74E+00 0.00E+00 1.75E+01 0.00E+00 3.30E+05 0.00E+00 Pr-1 44 3.01 E-54 1.25E-54 1.53E-53 0.00E+00 7.05E-55 0.00E+00 4.33E-61 0.00E+00 Nd-1 47 2.50E+00 2.89E+00 1.73E-01 0.00E+00 1.69E+00 0.OOE+00 1.39E+04 0.00E+00 W-187 3.26E+03 2.72E+03 9.53E+02 0.OOE+00 0.00E+00 0.00E+00 8.92E+05 0.00E+00 Np-239 1.84E+00 1.81 E-01 9.96E-02 0.00E+00 5.63E-01 0.00E+00 3.70E+04 0.00E+00
- R VALUES IN UNITS OF MREMYR PER iLCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMIYR PER piCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE
,f'4 ,r g :Y.NUMBER:
LI OFFSITE DOSE CALCULATION H4 EL ~MANUAL (ODCM) REV: 17
_________________ I_ Page 123 of 221 Table 5.5-9 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Teen PATHWAY = COW MILK AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN - I H-3 O.OOE+00 9.94E+02 9.94E+02 9.94E+02 9.94E+02 9.94E+02 9.94E+02 9.94E+02 C-14 1.08E+10 2.16E+09 2.16E+09 2.16E+09 2.16E+09 2.16E+09 2.16E+09 0.OOE+00 Na-24 5.25E+08 5.25E+08 5.25E+08 5.25E+08 5.25E+08 5.25E+08 5.25E+08 0.OOE+00 P-32 1.55E+10 9.62E+08 6.02E+08 O.OOE+00 O.OOE+00 O.OOE+O0 1.30E+09 0.OOE+00 Cr-51 O.OOE+00 O.OOE+OO 2.32E+04 1.29E+04 5.08E+03 3.31 E+04 3.90E+06 0.OOE+ 00 Mn-54 O.OOE+00 7.57E+06 1.50E+06 O.OOE+00 2.26E+06 O.OOE+00 1.55E+07 0.OOE+00 MN-56 O.OOE+00 3.69E-02 6.57E-04 O.OOE+00 4.67E-03 O.OOE+00 2.43E-01 0.OOE+00 Fe-55 2.43E+07 1.72E+07 4.02E+06 O.OOE+00 O.OOE+00 1.09E+07 7.46E+06 0.OOE+00 Fe-59 2.44E+07 5.70E+07 2.20E+07 O.OOE+00 O.OOE+00 1.80E+07 1.35E+08 0.00E+00 Co-58 O.OOE+00 3.86E+06 8.90E+06 O.OOE+00 O.OOE+00 O.OOE+00 5.32E+07 0.OOE+00 Co-60 O.OOE+00 1.57E+07 3.54E+07 O.OOE+00 O.OOE+00 O.OOE+00 2.05E+08 0.OOE+00 Ni-63', 7.37E+09 5.21 E+08 2.50E+08 O.OOE+00 O.OOE+00 O.OOE+00 8.29E+07 0.OOE+OO Ni-65 3.40E-01 4.34E-02 I1.98E-02 O.OOE+00 O.OOE+00 O.OOE+00 2.35E+00 0.OOE+OO Cu-64 O.OOE+00 2.19E+04 1.03E+04 O.OOE+00 5.54E+04 O.OOE+00 1.70E+06 0.OOE+00 Zn-65 1.31 E+09 4.54E+09 2.12E+09 O.OOE+00 2.91 E+06 O.OOE+00 1.92E+09 0.OOE+00 Zn-69 1.95E-12 3.72E-12 2.60E-13 O.OOE+00 2.43E-12 O.OOE+00 6.85E-12 0.OOE+00 Br-83 O.OOE+00 O.OOE+O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+Ob O.OOE+00 0.OOE+00 Br-84 O.OOE+OO O.OOE+00 1.47E-23 b.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 0.OOE+00 Br-85 O.OOE+00 O.OOE+00 6.26E-288 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 Rb-86 O.OOE+00 2.23E+09 1.05E+09 O.OOE+00 O.OOE+00 O.OOE+00 3.30E+08 0.OOE+00 Rb-88 O.OOE+00 1.97E-45 1.05E-45 O.OOE+00 O.OOE+00 O.OOE+00 1.69E-52 0.OOE+00 Rb-89 O.OOE+00 2.81 E-53 1.48E-53 0.OOE+O O.OOE+00 O.OOE+00 4.31 E-62 0.OOE+00 Sr-89 1.29E+09 O.OOE+00 3.69E+07 O.OOE+O0 O.OOE+00 O.OOE+00 1.53E+08 0.OOE+00 Sr-90 4.02E+10 O.OOE+00 9.93E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.13E+09 0.OOE+00 Sr-91 2.66E+04 O.OOE+00 1.06E+03 b.OOE+OO O.OOE+00 O.OOE+00 1.21 E+05 0.OOE+00 Sr-92 4.48E-01 O.OOE+0 1.91 E-02 O.OOE+00 O.OOE+00 O.OOE+OO 1.14E+01 0. OOE+00 Y-90 7.02E-02 O.OOE+00 1.89E-03 O.OOE+00 O.OOE+OO O.OOE+00 5.79E+02 0.OOE+00 Y-91M 5.53E-20 O.OOE+O0 2.11E-21 O.OOE+00 O.OOE+00 O.OOE+00 2.61 E-18 O.OOE+00 Y-91 7.57E+03 O.OOE+00 2.03E+02 b.OOE+OO O.OOE+00 O.OOE+00 3.1 OE+06 0.OOE+OO Y-92 8.84E-43 O.OOE+00 2.56E-44 O.OOE+00 O.OOE+00 O.OOE+00 2.43E-38 O.00E+00 Y-93 2.06E-01 0.OOE+00 5.65E-03 O.OOE+00 O.OOE+00 O.OOE+00 6.30E+03 0.00E+00 Zr-95 2.57E+02 8.12E+01 5.58E+01 O.OOE+OO 1.19E+02 O.OOE+00 1.87E+05 0.OOE+00 Zr-97 8.18E-10 1.62E-10 7.46E-1 I O.OOE+00 2.45E-10 O.OOE+00 4.38E-05 0.OOE+00 Nb-95 6.57E+04 3.64E+04 2.OOE+04 O.OOE+00 3.53E+04 O.OOE+00 1.56E+08 0.OOE+00 Mo-99 O.OOE+00 2.81 E+04 5.35E+03 O.OOE+00 6.42E+04 O.OOE+00 5.03E+04 0.OOE+00 Tc-99M 7.01 E-23 1.96E-22 2.53E-21 O.OOE+00 2.92E-21 1.09E-22 1.28E-19 0.OOE+00 Tc-101 2.45E-60 3.49E-60 3.43E-59 O.OOE+00 6.31 E-59 2.12E-60 5.96E-67 0.OOE+00 Ru-103 8.51 E+02 O.OOE+00 3.64E+02 O.OOE+00 3.OOE+03 O.OOE+00 7.11 E+04 0.OOE-I00 Ru-1 05 7.84E-04 O.OOE+00 3.04E-04 O.OOE+00 9.89E-03 O.OOE+00 6.33E-01 0.00 E+00 Ru-106 2.07E+04 O.OOE+00 2.61 E+03 O.OOE+00 3.99E+04 O.OOE+00 9.92E+05 0.00E+OO Ag-1i1M 5.42E+07 5.13E+07 3.12E+07 O.OOE+00 9.78E+07 O.OOE+00 1.44E+10 O.OOE+OO Te-125M 1.64E+07 5.89E+06 2.19E+06 4.57E+06 O.OOE+00 O.OOE+00 4.82E+07 0.OOE+00 Te-127M 5.33E+07 1.89E+07 6.34E+06 1.27E+07 2.16E+08 O.OOE+00 1.33E+08 0.OOE+OO
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 124 of 221 Table 5.5-9 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Teen PATHWAY = COW MILK AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 5.99E+02 2.12E+02 1.29E+02 4.13E+02 2.43E+03 0.00E+00 4.63E+04 0.OOE+00 Te-129M 5.54E+07 2.06E+07 8.77E+06 1.79E+07 2.32E+08 0.00E+00 2.08E+08 0.OE+00 Te-129 2.67E-10 9.94 E- 11 6.48E- 1 1.90E-10 1.12E-09 0.OOE+00 1.46E-09 0.OOE+00 Te-131 M 3.35E+05 1.61 E+05 1.34E+05 2.42E+05 1.68E+06 0.OOE+00 1.29E+07 0.00E+00 Te-131 3.41 E-33 1.41 E-33 1.07E-33 2.63E-33 1.49E-32 0.OOE+00 2.80E-34 0.00E+00 Te-132 2.20E+06 1.39E+06 1.30E+06 1.47E+06 1.33E+07 0.OOE+00 4.41 E+07 0.00E+00 1-130 3.68E+05 1.07E+06 4.26E+05 8.69E+07 1.64E+06 0.OOE+00 8.19E+05 0.00E+00 1-131 2.64E+08 3.70E+08 1.99E+08 1.08E+1I 6.37E+08 0.OOE+00 7.31 E+07 0.OE+00 1-132 1.46E-01 3.82E-01 1.37E-01 1.29E+01 6.02E-01 0.00E+00 1.67E-01 0.OOE+00 1-133 3.54E+06 6.OOE+06 1.83E+06 8.37E+08 1.05E+07 0.00E+00 4.54E+06 0.OOE+00 1-134 1.81 E-12 4.79E-12 1.72E-12 7.98E-1 I 7.55E-12 0.00E+00 6.31 E-14 0.00E+00 1-135 1.14E+04 2.94E+04 1.09E+04 1.89E+06 4.64E+04 0.00E+00 3.26E+04 0.00E+00 Cs-134 5.40E+09 1.27E+10 5.90E+09 0.OOE+00 4.04E+09 1.54E+09 1.58E+08 0.00E+00 Cs-1 36 2.13E+08 8.38E+08 5.63E+08 0.OOE+00 4.56E+08 7.19E+07 6.74E+07 0.00E+00 Cs-1 37 7.83E+09 1.04E+10 3.63E+09 0.OOE+00 3.55E+09 1.38E+09 1.48E+08 0.00E+00 Cs-1 38 8.31 E-24 1.60E-23 7.98E-24 0.OOE+00 1.18E-23 1.37E-24 7.24E-27 0.OOE+00 Ba-139 4.11E-08 2.89E-i 1 1.20E-09 0.OOE+00 2.72E-1 1 1.99E-11 3.66E-07 0.OOE+00 Ba-140 2.32E+07 2.85E+04 1.50E+06 0.OOE+00 9.66E+03 1.92E+04 3.59E+07 0.OOE+00 Ba-141 7.36E-47 5.49E-50 2.46E-48 0.OOE+00 5.1 0E-50 3.76E-50 1.57E-52 0.OOE+00 Ba-142 2.51 E-80 2.51 E-83 1.54E-81 0.OOE+00 2.12E-83 1.67E-83 7.69E-92 0.00E+00 La-140 4.05E+00 1.99E+00 5.30E-01 0.00E+00 0.OOE+00 0.00E+00 1.14E+05 0.OOE+00 La-142 1.68E-11 7.48E-1 2 1.86E-12 0.OOE+00 0.00E+00 0.OOE+00 2.28E-07 0.OOE+00 Ce-141 4.14E+03 2.76E+03 3.17E+02 0.OOE+00 1.30E+03 0.OOE+00 7.90E+06 0.00E+00 Ce-143 3.82E+01 2.78E+04 3.11 E+00 0.OOE+00 1.25E+01 0.OOE+00 8.36E+05 0.OOE+00 Ce-i 44 3.49E+05 1.44E+05 1.87E+04 0.OOE+00 8.62E+04 0.OOE+00 8.77E+07 0.OOE+00 Pr-1 43 1.38E+02 5.53E+01 6.89E+00 0.OOE+00 3.21 E+01 0.00E+00 4.56E+05 0.00E+00 Pr-144 5.55E-54 2.27E-54 2.81 E-55 0.OOE+00 1.30E-54 0.00E+00 6.11E-57 0.00E+00 Nd-147 4.81 E+00 5.23E+00 3.13E-01 0.OOE+00 3.07E+00 0.00E+00 1.89E+04 0.00E+00 W-187 5.96E+03 4.86E+03 1.70E+03 0.00E+00 0.OOE+00 0.OOE+00 1.31 E+06 0.00E+00 Np-239 3.51 E+00 3.31 E-01 1.84E-01 0.OOE+00 1.04E+00 0.OOE+00 5.32E+04 0.00E+00
- R VALUES IN UNITS OF MREM/YR PER gCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M -MREMNYR PER pCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-10 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Child PATHWAY = COW MILK AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 O.OOE+00 I.57E+03 1.57E+03 1.57E+03 i .57E+03 I1.57E+03 1.57E+03 1.57E+03:
C-14 2.66E+10 5.32E+09 5.32E+09 5.32E+09 5.32E+09 5.32E+09 5.32E+09 0.OOE+00 Na-24 1.09E+09 1.09E+09 1.09E+09 1.09E+09 1.09E+09 1.09E+09 1.09E+09 0.OOE+00 P-32 3.83E+10 1.79E+09 1.48E+09 O.OOE+00 O.OOE+00 0.OOE+00 1.06E+09 0.OOE+00 Cr-51 O.OOE+00 O.OOE+00 4.73E+04 2.63E+04 7.17E+03 4.79E+04 2.51 E+06 0.OOE+00 Mn-54 O.OOE+O0 1.13E+07 3.02E+06 O.OOE+00 3.17E+06 0.OQE+00 9.50E+06 0.OOE+00 MN-56 O.OOE+00 6.44E-03 1.44E-03 O.OOE+00 7.79E-03 0.OQE+00 9.33E-01 0.OOE+00 Fe-55 6.10E+07 3.24E+07 1.OOE+07 O.OOE+00 O.OOE+00 I1.83E+07 6.OOE+06 0.OOE+00 Fe-59 5.66E+07 9.16E+07 4.56E+07 O.OOE+00 O.OOE+00 2.66E+07 9.54E+07 0.OOE+00 Co-58 O.OOE+00 5.90E+06 1.81 E+07 O.OOE+OO O.OOE+00 0.OOE+00 3.44E+07 0.OOE+00 Co-60 O.OOE+00 2.44E+07 7.19E+07 O.OOE+00 O.OOE+00 0.OOE+00 1.35E+08 0.OOE+00 Ni-63 1.85E+10 9.90E+08 6.29E+08 O.OOE+00 O.OOE+00 0.OOE+00 6.67E+07 0.OOE+00 Ni-65 8.30E-01 7.82E-02 4.56E-02 O.OOE+00 O.OOE+00 0.OOE+00 9.58E+00 0.OOE+00 Cu-64 O.OOE+00 3.85E+04 2.32E+04 O.OOE+OO 9.29E+04 0.OOE+00 1.81 E+06 0.OOE+00 Zn-65 2.57E+09 7.22E+09 4.25E+09 O.OOE+OO 4.31 E+09 0.OOE+00 1.20E+09 0.00E+00 Zn-69 4.80E-12 6.93E-12 6.41 E-13 O.OOE+OO 4.21 E-12 0.OOE+00 4.37E-10 0.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+OO b.OOE+OO O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Br-84 O.OOE+00 O.OOE+00 3.34E-23 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Br-85 O.OOE+00 O.OOE+00 1.54E-287 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Rb-86 O.OOE+00 4.13E+09 2.54E+09 O.OOE+00 O.OOE+00 0.OOE+00 2.66E+08 0.OOE+00 Rb-88 O.OOE+00 3.63E-45 2.52E-45 O.OOE+00 O.OOE+00 0.OOE+00 1.78E-46 0.OOE+00 Rb-89 O.OOE+00 4.94E-53 4.39E-53 O.OOE+OO O.OOE+00 0.OOE+00 4.30E-55 0.OOE+00 Sr-89 3.19E+09 O.OOE+00 9.1 OE+07 O.OOE+00 O.OOE+00 0.OOE+00 1.23E+08 0.OOE+00 Sr-90 6.80E+10 O.OOE+00 1.72E+10 O.OOE+00 O.OOE+00 0.00E+00 9.15E+08 0.OOE+00 Sr-91 6.52E+04 O.OOE+00 2.46E+03 O.OOE+00 O.OOE+00 0.OOE+00 1.44E+05 0OE+OO Sr-92 1.09E+00 O.OOE+00 4.39E-02 0.OOE+00 O.OOE+00 0.OOE+00 2.07E+01 0.OOE+00 Y-90 1.74E-01 O.OOE+00 4.65E-03 O.OOE+OO O.OOE+00 0.OOE+00 4.95E+02 0.OOE+OO Y-91 M 1.35E-19 O.OOE+00 6.68E-21 O.OOE+00 O.OOE+00 0.OOE+00 2.64E-16 0.OOE+00 Y-91 1.87E+04 O.OOE+00 5.OOE+02 O.OOE+00 O.OOE+00 0.OOE+00 2.49E+06 0.OOE+00 Y-92 2.17E-42 O.OOE+00 6.21 E-44 O.OOE+00 O.OOE+00 0.OOE+00 6.27E-38 0.OOE+00 Y-93 5.06E-01 O.OOE+00 1.39E-02 O.OOE+00 O.OOE+00 0.OOE+00 7.55E+03 0.00E+00 Zr-95 5.98E+02 1.31 E+02 1.17E+02 O.OOE+O0 1.88E+02 0.OOE+00 1.37E+05 0.OOE+00 Zr-97 1.99E-09 2.88E-10 1.70E-10 O.OOE+OO 4.13E-10 0.OOE+00 4.36E-05 0.OOE+00 Nb-95 1.48E+05 5.77E+04 4.12E+04 O.OOE+00 5.42E+04 0.OOE+00 1.07E+08 0.OOE+00 Mo-99 O.OOE+OO 5.11E+04 1.26E+04 O.OOE+00 1.09E+05 0.OOE+00 4.22E+04 0.OOE+00 Tc-99M 1.61 E-22 3.15E-22 5.23E-21 O.OOE+OO 4.58E-21 1.60E-22 1.80E-19 0.OOE+00 Tc-101 6.01 E-60 6.29E-60 7.98E-59 O.OOE+00 1.07E-58 3.33E-60 2.OOE-59 0.OOE+00 Ru-103 2.01 E+03 O.OOE+00 7.74E+02 O.OOE+OO 5.07E+03 0.OOE+00 5.20E+04 0.OOE+OO Ru-105 1.91 E-03 O.OOE+00 6.95E-04 O.OOE+OO 1.68E-02 0.OOE+00 1.25E+00 0.OOE+00 Ru-I 06 5.09E+04 O.OOE+00 6.36E+03 O.OOE+00 6.88E+04 0.OOE+00 7.93E+05 0.OOE+00 Ag-1I OM 1.18E+08 7.94E+07 6.34E+07 O.OOE+00 1.48E+08 0.OOE+00 9.44E+09 0.OOE+OO Te-125M 4.02E+07 1.09E+07 5.35E+06 1.13E+07 O.OOE+00 0.OOE+00 3.87E+07 0.OOE+00 Te-127M 1.31 E+08 3.54E+07 1.56E+07 3.14E+07 3.75E+08 0.OOE+00 1.06E+08 0.OOE-'00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 t1 l, l (ODCM)
MANUAL REV: 17 Page 126 of 221 Table 5.5-10 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Child PATHWAY = COW MILK AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-1 27 1.47E+03 3.97E+02 3.16E+02 1.02E+03 4.19E+03 0.OOE+00 5.76E+04 0.OOE+00 Te-129M 1.37E+08 3.81 E+07 2.12E+07 4.40E+07 4.01 E+08 0.OOE+00 1.67E+08 0.OOE+00 Te-129 6.58E-10 1.84E-10 1.56E-10 4.69E-10 1.92E-09 0.00E+00 4.09E-08 0.OOE+00 Te-131M 8.17E+05 2.82E+05 3.01 E+05 5.81 E+05 2.73E+06 0.OOE+00 1.15E+07 0.00E+00 Te-131 8.38E-33 2.55E-33 2.49E-33 6.41 E-33 2.53E-32 0.OOE+00 4.40E-32 0.OOE+00 Te-132 5.24E+06 2.32E+06 2.80E+06 3.38E+06 2.15E+07 0.OOE+00 2.34E+07 0.OOE+00 1-130 8.62E+05 1.74E+06 8.97E+05 1.92E+08 2.60E+06 0.OOE+00 8.15E+05 0.OOE+00 1-131 6.41 E+08 6.44E+08 3.66E+08 2.13E+11 1.06E+09 0.OOE+00 5.74E+07 0.OOE+00 1-132 3.46E-01 6.35E-01 2.92E-01 2.95E+01 9.72E-01 0.OOE+00 7.48E-01 0.OOE+00 1-133 8.59E+06 1.06E+07 4.02E+06 1.97E+09 1.77E+07 0.OOE+00 4.28E+06 0.OOE+00 1-134 4.28E-12 7.94E-1 2 3.65E-12 1.83E-10 1.21 E-11 0.OOE+00 5.27E-12 0.OOE+00 1-135 2.70E+04 4.87E+04 2.30E+04 4.31 E+06 7.46E+04 0.OOE+00 3.71 E+04 0.OOE+00 Cs-1 34 1.25E+10 2.05E+10 4.31 E+09 0.OOE+00 6.34E+09 2.27E+09 1.1OE+08 0.OOE+00 Cs-1 36 4.81 E+08 1.32E+09 8.55E+08 0.00E+00 7.04E+08 1.05E+08 4.64E+07 0.OOE+00 Cs-137 1.89E+10 1.81 E+ 10 2.67E+09 0.00E+00 5.89E+09 2.12E+09 1.13E+08 0.OOE+00 Cs-1 38 2.02E-23 2.80E-23 1.78E-23 0.OOE+00 1.97E-23 2.12E-24 1.29E-23 0.00E+00 Ba-i 39 1.01 E-07 5.39E- 1 2.93E-09 0.OOE+00 4.71 E-11 3.17E-1i1 5.83E-06 0.OOE+00 Ba-1 40 5.61 E+07 4.92E+04 3.28E+06 0.OOE+00 1.60E+04 2.93E+04 2.84E+07 0.OOE+00 Ba-141 1.81 E-46 1.01 E-49 5.89E-48 0.OOE+00 8.77E-50 5.95E-49 1.03E-46 0.OOE+00 Ba-142 6.04E-80 4.35E-83 3.37E-81 0.OOE+00 3.52E-83 2.56E-83 7.88E-82 0.OOE+00 La-140 9.70E+00 3.39E+00 1.06E+00 0.OOE+00 0.OOE+00 0.OOE+00 9.45E+04 0.OOE+00 La-142 4.07E-11 1.30E-1 1 4.06E-12 0.OOE+00 0.OOE+00 0.OOE+00 2.57E-06 0.00E+00 Ce-141 1.02E+04 5.08E+03 7.54E+02 0.OOE+00 2.23E+03 0.OOE+00 6.34E+06 0.OOE+00 Ce-1 43 9.38E+01 5.08E+04 7.36E+00 0.OOE+00 2.13E+01 0.OOE+00 7.44E+05 0.OOE+00 Ce-144 8.60E+05 2.69E+05 4.59E+04 0.OOE+00 1.49E+05 0.OOE+00 7.03E+07 0.OOE+00 Pr-143 3.43E+02 1.03E+02 1.70E+01 0.OOE+00 5.57E+01 0.OOE+00 3.70E+05 0.OOE+00 Pr-144 1.37E-53 4.24E-54 6.90E-55 0.OOE+00 2.24E-54 0.OOE+00 9.14E-51 0.OOE+00 Nd-147 1.18E+01 9.55E+00 7.40E-01 0.OOE+00 5.24E+00 0.OOE+00 1.51 E+04 0.OOE+00 W-187 1.45E+04 8.56E+03 3.84E+03 0.OOE+00 0.OOE+00 0.OOE+00 1.20E+06 0.OOE+00 Np-239 8.63E+00 6.20E-01 4.35E-01 0.OOE+00 1.79E+00 0.OOE+00 4.58E+04 0.OOE+00 R VALUES IN UNITS OF MREMYR PER PCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMYR PER 1iCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE H
NUMBER:
k OFFSITE DOSE CALCULATION R H4 MANUAL (ODCM) RV Pg1o217l
-~~~~~~~ r. ~~~~~~~~~~Page 127 of 2211 Table 5.5-11 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Infant PATHWAY = COW MILK AGE GROUP = INFANT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 O.OOE+00 2.38E+03 2.38E+03 2.38E+03 2.38E+03 2.38E+03 2.38E+03 2.38E+03 C-14 5.21E+10 1.11E+10 1.11E+10 1.11E+10 1.11E+10 1.11E+10 1.11E+10 O.OOE+00 Na-24 1.90E+09 1.90E+09 1.90E+09 1.90E+09 1.90E+09 1.90E+09 1.90E+09 O.OOE+00' P-32 7.89E+10 4.64E+09 3.22E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.07E+09 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 7.49E+04 4.89E+04 1.07E+04 9.51 E+04 2.18E+06 0.OOE+00 Mn-54 O.OOE+O0 2.11 E+07 4.77E+06 O.OOE+00 4.67E+06 O.OOE+00 7.73E+06 O.OOE+00 MN-56 O.OOE+00 1.58E-02 2.72E-03 O.OOE+00 1.36E-02 O.OOE+00 1.43E+00 O.OOE+00 Fe-55 7.37E+07 4.76E+07 1.27E+07 O.OOE+00 O.OOE+OO 2.33E+07 6.05E+06 O.OOE+00 Fe-59 1.06E+08 1.85E+08 7.28E+07 O.OOE+00 O.OOE+00 5.46E+07 8.82E+07 O.OOE+00 Co-58 O.OOE+00 1.18E+07 2.93E+07 O.OOE+00 O.OOE+00 O.OOE+00 2.94E+07 O.OOE+00 Co-60 O.OOE+OO 4.98E+07 1.18E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.18E+08 O.OOE+00 Ni-63 2.18E+10 1.35E+09 7.56E+08 O.OOE+00. O.OOE+00 O.OOE+00 6.70E+07 O.OOE+00 Ni-65 1.76E+00 1.99E-01 9.05E-02 O.OOE+00 O.OOE+00 O.OOE+00 1.52E+01 O.OOE+00 Cu-64 O.OOE+00 9.56E+04 4.43E+04 O.OOE+00 1.62E+05 O.OOE+00 1.96E+06 O.OOE+00 Zn-65 2.51E+09 1.18E+10 5.45E+09 O.OOE+00 5.74E+09 O.OOE+00 9.99E+09 O.OOE+00 Zn-69 1.02E-11 1.84E-11 1.37E-12 O.OOE+00 7.65E-12 O.OOE+00 1.50E-09 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 6.43E-23 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.O0E+OO 3.29E-287 O.OOE+O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.05E+10 5.18E+09 0.OOE+00 O.OOE+00 O.OOE+00 2.68E+08 O.OOE+00 Rb-88 O.OOE+00 9.52E-45 5.22E-45 O.OOE+00 O.OOE+00 O.OOE+00 9.27E-45 O.OOE+OO Rb-89 O.OOE+00 .1.21 E-52 8.31 E-53 O.OOE+00 O.OOE+00 O.OOE+00 4.11 E-53 O.OOE+00 Sr-89 6.06E+09 O.OOE+00 1.74E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.25E+08 O.OOE+00 Sr-90 7.40E+10 O.OOE+00 1.88E+10 O.OOE+00 O.OOE+00 O.O0E+OO 9.23E+08 O.OOE+OO Sr-91 1.36E+05 O.OOE+O0 4.92E+03 O.OOE+00 O.OOE+O0 O.OOE+00 1.61 E+05 O.OOE+00 Sr-92 2.33E+00 O.OOE+00 8.65E-02 O.OOE+00 O.OOE+00 O.OOE+00 2.51 E+01 O.OOE+00 Y-90 3.67E-01 O.OOE+00 .9.85E-03 O.OOE+00 O.OOE+O0 O.OOE+00 5.07E+02 O.OOE+00 Y-91M 2.86E-19 O.OOE+00 9.75E-21 O.OOE+00 O.OOE+00 O.OOE+00 9.54E-16 O.OOE+00 Y-91 3.54E+04 O.OOE+00 9.35E+02 O.OOE+00 O.OOE+00 O.OOE+00 2.52E+06 O.OOE+00 Y-92 4.61 E-42 O.OOE+00 1.30E-43 O.OOE+00 O.OOE+00 O.OOE+00 8.80E-38 O.OOE+00 Y-93 1.08E+00 O.OOE+00 2.94E-02 O.OOE+00 O.OOE+00 O.OOE+00 8.53E+03 O.OOE+00 Zr-95 1.06E+03 2.59E+02 1.83E+02 O.OOE+O0 2.79E+02 O.OOE+00 1.29E+05; O.OOE+00 Zr-97 4.22E-09 7.23E-10 3.30E-10 O.OOE+00 7.29E-10 O.OOE+00 4.61E-05 O.OOE+00 Nb-95 2.77E+05 1.14E+05 6.59E+04 O.OOE+00 8.17E+04 O.OOE+O0 9.62E+07 O.OOE+00 Mo-99 O.OOE+00 1.31 E+05 2.55E+04 O.OOE+00 1.95E+05 O.OOE+00 4.30E+04 O.OOE+00 Tc-99M 3.35E-22 6.90E-22 8.89E-21 O.OOE+00 7.42E-21 3.61 E-22 2.00E-19 O.OOE+00 Tc-101 1.28E-59 1.61E-59 1.59E-58 O.OOE+00 1.91E-58 8.77E-60 2.73E-57 O.OOE+00 Ru-103 4.08E+03 O.0OE+OO 1.36E+03 O.OOE+OO 8.48E+03 O.OOE+00 4.96E+04 O.OOE+00 Ru-105 4.04E-03 O.OOE+00 1.34E-03 O.OOE+00 2.97E-02 O.OOE+00 1.61 E+00 O.OOE+00 Ru-106 1.05E+05 O.OOE+00 1.31 E+04 O.OOE+OO 1.24E+05 O.OOE+00 7.97E+05 O.OOE+00 Ag-11 OM 2.17E+08 1.58E+08 1.05E+08 O.OOE+00 2.27E+08 O.OOE+00 8.22E+09 O.OOE+00 Te-125M 8.21E+07 2.74E+07 1.11E+07 2.76E+07 O.OOE+00 O.OOE+00 3.91E+07 O.OOE+00 Te-127M 2.66E+08 8.92E+07 3.22E+07 7.69E+07 6.55E+08 O.OOE+00 1.07E+08 O.OOE+00
I PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-11 R Values for the Prairie Island Nuclear Generating Plant*
- Cow Milk, Infant PATHWAY = COW MILK AGE GROUP = INFANT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 3.13E+03 1.05E+05 6.73E+02 2.55E+03 7.64E+03 0.OOE+00 6.57E+04 0.OOE+00 Te-129M 2.80E+08 9.62E+07 4.32E+07 1.08E+08 7.01 E+08 0.OOE+00 1.67E+08 0.OOE+00 Te-129 1.39E-09 4.81E-10 3.25E-10 1.17E-09 3.47E-09 0.OOE+00 1.11E-07 0.0OE+00 Te-131M 1.72E+06 6.94E+03 5.73E+05 1.41E+06 4.78E+06 0.OOE+00 1.17E+07 0.0OE+00 Te-131 1.78E-32 6.56E-33 4.95E-33 1.58E-32 4.54E-32 0.OOE+00 7.17E-31 0.OOE+00 Te-132 1.08E+07 5.35E+06 4.99E+06 7.89E+06 3.34E+07 O.00E+00 1.98E+07 0.OOE+00 1-130 1.77E+06 3.90E+06 1.56E+06 4.37E+08 4.28E+06 0.OOE+00 8.35E+05 0.00E+00 1-131 1.34E+09 1.58E+09 6.93E+08 5.18E+11 1.84E+09 O.OOE+00 5.62E+07 0.OE+00 1-132 7.17E-01 1.46E+00 5.18E-01 6.83E+01 1.62E+00 0.OOE+00 1.18E+00 0.0OE+00 1-133 1.81 E+07 2.64E+07 7.74E+06 4.80E+09 3.11 E+07 0.OOE+00 4.47E+06 0.00E+00 1-134 8.87E-12 1.82E-11 6.24E-12 4.24E-10 2.03E-11 0.OOE+00 1.88E-11 0.00E+00 1-135 5.62E+04 1.12E+05 4.08E+04 9.96E+06 1.25E+05 0.OOE+00 4.05E+04 0.OOE+00 Cs-1 34 2.01E+10 3.74E+10 3.78E+09 0.OOE+00 9.64E+09 3.95E+09 1.02E+08 0.OE+00 Cs-136 9.39E+08 2.76E+09 1.03E+09 0.OOE+00 1.10E+09 2.25E+08 4.19E+07 0.OOE+00 Cs-137 3.01E+10 3.53E+10 2.50E+09 0.OOE+00 9.46E+09 3.83E+09 1.1OE+08 0.OOE+00 Cs-138 4.25E-23 6.91 E-23 3.27E-23 0.OOE+00 3.45E-23 5.38E-24 1.10E-22 0.OOE+00 Ba-139 2.15E-07 1.42E-10 6.22E-09 0.00E+00 8.56E-11 8.63E-11 1.36E-05 0.OOE+00 Ba-140 1.15E+08 1.15E+05 5.95E+06 0.OOE+00 2.74E+04 7.09E+04 2.84E+07 0.OOE+00 Ba-141 3.84E-46 2.63E-49 1.21 E-47 0.00E+00 1.58E-49 1.60E-49 4.70E-45 O.OOE+00 Ba-142 1.27E-79 1.06E-82 6.26E-81 0.OOE+00 6.09E-83 6.40E-83 5.25E-79 0.OOE+00 La-140 2.03E+01 7.99E+00 2.06E+00 0.OOE+00 0.OOE+00 0.OOE+00 9.39E+04 0.OOE+00 La-142 8.54E-1 1 3.14E-1 1 7.51 E-12 0.OOE+00 0.OOE+00 0.OOE+00 5.33E-06 0.OOE+00 Ce-141 2.02E+04 1.23E+04 1.45E+03 0.OOE+00 3.80E+03 0.OOE+00 6.36E+06 0.OOE+00 Ce-143 1.99E+02 1.32E+05 1.50E+01 0.OOE+00 3.84E+01 0.OOE+00 7.69E+05 0.OOE+00 Ce-144 1.23E+06 5.04E+05 6.90E+04 0.OOE+00 2.04E+05 0.OOE+00 7.07E+07 0.OOE+00 Pr-143 7.09E+02 2.65E+02 3.51 E+01 0.OOE+00 9.86E+01 0.OOE+00 3.74E+05 0.OOE+00 Pr-144 2.92E-53 1.13E-53 1.47E-54 0.OOE+00 4.09E-54 0.OOE+00 5.24E-49 O.OOE+00 Nd-147 2.34E+01 2.40E+01 1.47E+00 0.OOE+00 9.26E+00 0.OOE+00 1.52E+04 0.OOE+00 W-187 3.04E+04 2.12E+04 7.31E+03 0.OOE+00 0.OOE+00 0.OOE+00 1.24E+06 0.OOE+00 Np-239 1.82E+01 1.63E+00 9.22E-01 0.OOE+00 3.25E+00 0.OOE+00 4.72E+04 0.OOE+00
- R VALUES IN UNITS OF MREMIYR PER iCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREM/YR PER piCI/SEC FOR ALL OTHERS.
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE
- ~~~~~~~~~~~~NUMBER:
OFFSITE DOSE CALCULAION H4*
MANUAL (ODCM) REV: 17
_________________ Page 129 of 221 Table 5.5-12 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Adult PATHWAY = GOAT MILK AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN -
H-3 O.OOE+00 1.56E+03 1.56E+03 1.56E+03 1.56E+03 1.56E+03 1.56E+03 1.56E+03 C-14 5.87E+09 1.17E+09 1.17E+09 1.17E+09 1.17E+09 1.17E+09 1.17E+09 O.OOE+00 Na-24 3.61 E+07 3.61 E+07 3.61 E+07 3.61 E+07 3.61 E+07 3.61 E+07 3.61 E+07 O.OOE+00 P-32 1.01 E+10 6.80E+08 3.90E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.14E+09 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 1.56E+03 9.52E+02 3.51 E+02 2.11E+03 4.01 E+05 O.OOE+00 Mn-54 O.OOE+00 5.45E+05 1.04E+05 O.OOE+00 1.62E+05 O.OOE+00 1.67E+06 O.OOE+00 MN-56 O.OOE+00 2.50E-04 4.43E-05 O.OOE+00 3.17E-04 O.OOE+00 7.97E-03 O.OOE+00 Fe-55 1.78E+05 1.23E+05 2.87E+04 O.OOE+00 O.OOE+00 6.87E+04 7.06E+04 O.OOE+OO Fe-59 1.82E+05 4.28E+05 1.64E+05 O.OOE+00 O.OOE+00 1.1 9E+05 1.43E+06 O.OOE+OO Co-58 O.OOE+00 2.75E+05 6.17E+05 O.OOE+00 O.OOE+00 O.OOE+00 5.58E+06 O.OOE+00 Co-60 O.OOE+00 1.11E+06 2.45E+06 O.OOE+00 O.OOE+00 O.OOE+00 2.09E+07 O.OOE+O0 Ni-63 5.03E+08 3.49E+07 1.69E+07 O.OOE+00 O.OOE+00 O.OOE+00 7.28E+06 O.OOE+00 Ni-65 2.23E-02 2.89E-03 1.32E-03 O.OOE+OO O.OOE+00 O.OOE+00 7.34E-02 O.OOE+00 Cu-64 O.OOE+00 1.37E+03 6.43E+02 O.OOE+OO 3.45E+03 O.OOE+00 1.17E+05 O.OOE+00 Zn-65 1.02E+08 3.25E+08 1.47E+08 O.OOE+OO 2.18E+08 O.OOE+00 2.05E+08 O.OOE+00 Zn-69 1.27E-13 2.43E-13 1.69E-14 O.OOE+00 1.58E-13 O.OOE+00 3.66E-14 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 9.89E-25 O.OOE+00 O.OOE+00 O.OOE+00 7.77E-30 O.OOE+00 Br-85 0.OOE+00 O.OOE+00 4.09E-289 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.47E+08 6.84E+07 O.OOE+0O O.OOE+00 O.OOE+00 2.89E+07 O.OOE+00 Rb-88 O.OOE+00 1.30E-46 6.91 E-47 O.OOE+00 O.OOE+00 O.OOE+00 1.80E-57 O.OOE+00 Rb-89 O.OOE+00 1.91 E-54 1.34E-54 O.OOE+00 O.OOE+Ob O.OOE+00 1.11 E-67 O.OOE+00 Sr-89 1.47E+09 O.OOE+00 4.21 E+07 O.OOE+00 O.OOE+00 O.OOE+00 2.35E+08 O.OOE+00 Sr-90 5.98E+10 O.OOE+00 1.47E+10 O.OOE+00 O.OOE+00 O.OOE+00 1.73E+09 O.OOE+00 Sr-91 3.04E+04 O.OOE+00 1.23E+03 O.OOE+00 O.OOE+00 O.OOE+00 1.45E+05 O.OOE+00 Sr-92 5.14E-01 O.OOE+00 2.22E-02 O.OOE+00 O.OOE+00 O.OOE+00 1.02E+01 O.OOE+00 Y-90 4.58E-03 O.OOE+OO 1.23E-04 O.OOE+OO O.OOE+00 O.OOE+00 4.86E+01 O.OOE+00 Y-91 M 3.62E-21 O.OOE+00 1.40E-22 b.O0E+OO O.OOE+00 O.OOE+00 1.06E-20 O.OOE+00 Y-91 4.94E+02 O.OOE+00 1.32E+01 O.OOE+00 O.OOE+OO O.OOE+00 2.72E+05 O.OOE+00 Y-92 5.74E-44 O.OOE+00 1.68E-45 O.OOE+00 O.OOE+OO O.OOE+00 1.01 E-39 O.OOE+00 Y-93 1.34E-02 O.OOE+OO 3.70E-04 - O.OOE+00 O.OOE+OO O.OOE+00 4.25E+02 O.OOE+00 Zr-95 1.77E+01 5.66E+00 3.83E+00 O.OOE+00 8.88E+00 O.OOE+00 1.79E+04 O.OOE+00 Zr-97 5.39E-1 1 1.09E-11 4.98E-12 O.OOE+00 1.64E-11 O.OOE+00 3.37E-06 O.OOE+00 Nb-95 4.62E+03 2.57E+03 1.38E+03 O.OOE+00 2.54E+03 O.OOE+00 1.56E+07 O.OOE+00 Mo-99 O.OOE+00 1.87E+03 3.55E+02 O.OOE+OO 4.22E+03 O.OOE+00 4.32E+03 O.OOE+00 Tc-99M 4.85E-24 1.37E-23 1.75E-22 O.OOE+00 2.08E-22 6.72E-24 8.11E-21 O.OOE+00 Tc-i 01 1.61 E-61 2.32E-61 2.27E-60 O.OOE+00 4.17E-60 1.1 8E-61 6.97E-73 O.OOE+00 Ru-103 5.74E+01 O.OOE+00 2.47E+01 O.OOE+00 2.19E+02 O.OOE+00 6.70E+03 O.OOE+00 Ru-105 5.15E-05 O.OOE+00 2.03E-05 O.OOE+OO 6.66E-04 O.OOE+00 3.15E-02 O.OOE+00 Ru-106 1.35E+03 O.OOE+OO 1.71 E+02 O.OOE+OO 2.61 E+03 O.OOE+00 8.74E+04 .OOE+OO Ag-1I1M 3.93E+06 3.64E+06 2.16E+06 O.OOE+00 7.15E+06 O.OOE+00 1.48E+09 O.OOE+00 Te-125M 1.06E+06 3.86E+05 1.43E+05 3.20E+05 4.33E+06 O.OOE+00 4.25E+06 O.OOE+00 Te-127M 3.47E+06 1.24E+06 4.23E+05 8.87E+05 1.41 E+07 O.OOE+00 1.16E+07 O.0OE+OO
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-12 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Adult PATHWAY = GOAT MILK AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 3.88E+01 1.39E+01 8.40E+00 2.87E+01 1.58E+02 0.OOE+00 3.06E+03 0.00E+00 Te-129M 3.63E+06 1.36E+06 5.75E+05 1.25E+06 1.52E+07 0.00E+00 1.83E+07 0.00E+00 Te-129 1.74E-1 1 6.53E-12 4.23E-1 2 1.33E-11 7.30E-1 1 0.OOE+00 1.31 E-1I 0.00E+00 Te-131M 2.21 E+04 1.08E+04 9.01 E+03 1.71 E+04 1.1OE+05 0.OOE+00 1.07E+06 0.00E+00 Te-1 31 2.24E-34 9.36E-35 7.08E-35 1.84E-34 9.82E-34 0.OOE+00 3.17E-35 0.00E+00 Te-132 1.47E+05 9.54E+04 8.95E+04 1.05E+05 9.19E+05 0.OOE+00 4.51 E+06 0.OOE+00 1-130 2.52E+05 7.42E+05 2.93E+05 6.29E+07 1.16E+06 0.OOE+00 6.39E+05 0.OOE+00 1-131 1.75E+08 2.50E+08 1.43E+08 8.19E+10 4.28E+08 0.00E+00 6.59E+07 0.00E+00 1-132 9.89E-02 2.64E-01 9.25E-02 9.25E+00 4.21 E-0I 0.OOE+00 4.97E-02 0.00E+00 1-133 2.32E+06 4.04E+06 1.23E+06 5.94E+08 7.05E+06 0.E00+00 3.63E+06 0.00E+00 1-134 1.22E-12 3.31 E-12 1.19E-12 5.74 E-1 1 5.27E-1 2 0.OOE+00 2.89E-15 0.00E+00 1-135 7.71 E+03 2.02E+04 7.45E+03 1.33E+06 3.24E+04 0.OOE+00 2.28E+04 0.OOE+00 Cs-i 34 9.34E+09 2.22E+10 1.82E+10 0.OOE+00 7.19E+09 2.39E+09 3.89E+08 0.OOE+00 Cs-1 36 3.75E+08 1.48E+09 1.07E+09 0.OOE+00 8.24E+08 1.13E+08 1.68E+08 0.OOE+00 Cs-I 37 1.30E+10 1.77E+10 1.16E+10 0.OOE+00 6.02E+09 2.OOE+09 3.43E+08 0.OOE+00 Cs-1 38 1.37E-23 2.71 E-23 1.34E-23 0.OOE+00 2.00E-23 1.97E-24 1.16E-28 0.OOE+00 Ba-1 39 2.67E-09 1.90E-12 7.81 E-1I 0.OOE+00 1.78E-12 1.08E-12 4.73E-09 0.00E+00 Ba-140 1.55E+06 1.94E+03 1.01 E+05 0.OOE+00 6.60E+02 1.11 E+03 3.18E+06 0.OOE+00 Ba-141 4.80E-48 3.63E-51 1.62E-49 0.OOE+00 3.38E-51 2.06E-51 2.26E-57 0.00E+00 Ba-142 1.66E-81 1.71 E-84 1.04E-82 0.OOE+00 1.44E-84 9.66E-85 2.34E-99 0.OOE+00 La-140 2.71 E-01 1.36E-01 3.61 E-02 0.OOE+00 0.OOE+00 0.OOE+00 1.OOE+04 0.OOE+00 La-142 1.12E-12 5.09E-13 1.27E-13 0.00E+00 0.OOE+00 0.OOE+00 3.72E-09 0.00E+00 Ce-141 2.71 E+02 1.83E+02 2.08E+01 0.OOE+00 8.50E+01 0.OOE+00 7.OOE+05 0.OOE+00 Ce-143 2.49E+00 1.84E+03 2.04E-01 0.OOE+00 8.12E-01 0.OOE+00 6.89E+04 0.OOE+00 Ce-144 2.27E+04 9.50E+03 1.22E+03 0.OOE+00 5.64E+03 0.OOE+00 7.69E+06 0.OOE+00 Pr-143 9.04E+00 3.63E+00 4.48E-01 0.OOE+00 2.09E+00 0.OOE+00 3.96E+04 0.OOE+00 Pr-1 44 3.61 E-55 1.50E-55 1.83E-54 0.OOE+00 8.45E-56 0.OOE+00 5.19E-62 0.OOE+00 Nd-147 3.OOE-01 3.46E-01 2.07E-02 0.OOE+00 2.03E-01 0.OOE+00 1.66E+03 0.OOE+00 W-187 3.91 E+02 3.27E+02 1.14E+02 0.OOE+00 0.OOE+00 0.OOE+00 1.07E+05 0.OOE+00 Np-239 2.20E-01 2.17E-02 1.19 E-02 0.OOE+00 6.76E-02 0.OOE+00 4.45E+03 0.00E+00
- R VALUES IN UNITS OF MREM/YR PER PiCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M 2 -MREM/YR PER 1iCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-13 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Teen PATHWAY = GOAT MILK AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 O.OOE+00 2.03E+03 2.03E+03 2.03E+03 2.03E+03 2.03E+03 2.03E+03 2.03E+03 C-14 1.08E+10 2.16E+09 2.16E+09 2.16E+09 2.16E+09 2.16E+09 2.16E+09 O.OOE+00 Na-24 6.30E+07 6.30E+07 6.30E+07 6.30E+07 6.30E+07 6.30E+07 6.30E+07 O.OOE+00 P 1.86E+10 1.15E+09 7.22E+08 O.OOE+00 O.OOE+00 O.OOE+Ob 1.57E+09 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 2.78E+03 1.55E+03 6.1 0E+02 3.97E+03 4.68E+05 O.OOE+00 Mn-54 O.OOE+00 9.08E+05 1.80E+05 O.OOE+00 2.71 E+05 O.OOE+00 1.86E+06 O.OOE+00 MN-56 O.OOE+00 4.43E-03 7.88E-05 O.OOE+00 5.61 E-04 O.OOE+00 2.92E-02 O.OOE+00 Fe-55 3.16E+05 2.24E+05 5.23E+04 O.OOE+00 O.OOE+00 1.42E+05 9.70E+04 O.OOE+00 Fe-59 3.17E+05 7.41 E+05 2.86E+05 O.OOE+00 O.OOE+00 2.34E+05 i1.75E+06 O.OOE+00 Co-58 O.OOE+Ob 4.63E+05 1.07E+06 O.OOE+00 O.OOE+00 O.OOE+00 6.39E+06 O.OOE+00 Co-60 O.OOE+00 1.88E+06 4.24E+06 O.OOE+00 O.OOE+00 O.OOE+00 2.45E+07 O.OOE+00 K>y; Ni-63 8.85E+08 6.25E+07 3.OOE+07 O.OOE+00 O.OOE+OO O.OOE+00 9.95E+06 O.OOE+00 Ni-65 4.08E-02 5.21 E-03 2.37E-03 O.OOE+00 O.OOE+00 O.OOE+00 2.82E-01 O.OOE+00 Cu-64 O.OOE+00 2.44E+03 1.15E+03 O.OOE+00 6.17E+03 O.OOE+00 1.89E+05 O.OOE+00 Zn-65 1.57E+08 5.45E+08 2.54E+08 O.OOE+00 3.49E+05 O.OOE+00 2.31 E+08 O.OOE+00 Zn-69 2.34E-13 4.46 E-13 3.12E-14 O.OOE+00 2.92E-13 O.OOE+00 8.22E-13 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 0.OOE+00 O.OOE+00 1.77E-24 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 7.51 E-289 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 2.67E+08 1.26E+08 O.OOE+00 O.OOE+00 O.OOE+00 3.96E+07 O.OOE+00 Rb-88 O.OOE+00 2.37E-46 1.26E-46 O.OOE+00 O.OOE+00 O.OOE+00 2.03E-53 O.OOE+00 Rb-89 O.OOE+00 3.38E-54 1.77E-54 O.OOE+00 O.OOE+00 O.OOE+00 5.17E-63 O.OOE+00 Sr-89 2.70E+09 O.OOE+00 7.74E+07 O.OOE+00 O.OOE+00 O.OOE+00 3.22E+08 O.OOE+00 Sr-90 8.45E+10 O.OOE+00 2.09E+1 0 O.OOE+00 O.OOE+00 O.OOE+00 2.37E+09 O.OOE+00 Sr-91 5.58E+04 O.OOE+00 2.22E+03 0.OOE+00 O.OOE+00 O.OOE+00 2.53E+05 O.OOE+00 Sr-92 9.41 E-01 O.OOE+00 4.01 E-02 O.OOE+00 O.OOE+00 O.OOE+00 2.40E+01 O.OOE+00 Y-90 8.42E-03 O.OOE+00 2.27E-04 O.OOE+00 O.OOE+00 O.OOE+00 6.95E+01 O.OOE+00 Y-91M 6.63E-21 O.OOE+00 2.53E-22 O.OOE+00 O.OOE+00 O.OOE+00 3.13E-19 O.OOE+00 Y-91 9.09E+02 O.OOE+O0 2.44E+01 O.OOE+00 O.OOE+00 O.OOE+00 3.73E+05 O.OOE+00 Y-92 1.06E-43 0.OOE+00 . 3.07E-45 O.OOE+00 O.OOE+00 O.OOE+00 2.91 E-39 O.OOE+00 Y-93 2.47E-02 O.OOE+00 6.78E-04 O.OOE+00 O.OOE+00 O.OOE+00 7.56E+02 O.OOE+00 Zr-95 3.09E+01 9.74E+00 6.70E+00 O.OOE+00 1.43E+01 0.OOE+00 2.25E+04 O.OOE+00 Zr-97 9.82E-1 1 1.94E-1 1 8.95E-12 O.OOE+00 2.95E-1 1 O.OOE+00 5.26E-06 O.OOE+00 Nb-95 7.88E+03 4.37E+03 2.41 E+03 0.OOE+0O 4.24E+03 O.OOE+O0 1.87E+07 O.OOE+00 Mo-99 O.OOE+00 3.37E+03 6.42E+02 O.OOE+00 7.71 E+03 O.OOE+00 6.03E+03 O.OOE+00 Tc-99M 8.42E-24 2.35E-23 3.04E-22 O.OOE+00 3.50E-22 1.30E-23 1.54E-20 O.OOE+00 Tc-101 2.94E-61 4.18E-61 4.11E-60 O.OOE+00 7.57E-60 2.55E-61 7.15E-68 O.OOE+00 Ru-103 1.02E+02 O.OOE+00 4.37E+01 O.OOE+00 3.60E+02 O.OOE+00 8.53E+03 O.OOE+00 Ru-105 9.41 E-05 O.OOE+00 3.65E-05 O.OOE+00 1.19E-03 O.OOE+00 7.60E-02 O.OOE+00 Ru-106 2.48E+03 O.OOE+00 3.13E+02 O.OOE+00 4.79E+03 O.OOE+00 1.19E+05 O.OOE+00 Ag-110M 6.50E+06 6.15E+06 3.74E+06 O.OOE+00 1.17E+07 O.OOE+00 1.73E+09 O.OOE+00 Te-125M 1.96E+06 7.07E+05 2.62E+05 5.48E+05 O.OOE+00 O.OOE+00 5.79E+06 O.OOE+00 Te-127M 6.40E+06 2.27E+06 7.61 E+05 1.52E+06 2.59E+07 O.OOE+00 1.59E+07 O.OOE+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 13I f 2 Table 5.5-13 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Teen PATHWAY = GOAT MILK AGE GROUP = TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-1 27 7.19E+01 2.55E+01 1.55E+01 4.96E+01 2.91 E+02 O.OOE+00 5.55E+03 O.OOE+00 Te-129M 6.65E+06 2.47E+06 1.05E+06 2.15E+06 2.78E+07 O.OOE+0O 2.50E+07 O.OOE+00 Te-129 3.20E-11 1.19E-11 7.78E-1 2 2.28E-1 1 1.34E-10 O.OOE+00 1.75E-10 O.OOE+00 Te-131M 4.03E+04 1.93E+04 1.61 E+04 2.90E+04 2.01 E+05 O.OOE+00 1.55E+06 O.OOE+00 Te-1 31 4.10E-34 1.69E-34 1.28E-34 3.16E-34 1.79E-33 O.OOE+0O 3.36E-35 O.OOE+00 Te-132 2.64E+05 1.67E+05 1.56E+05 1.76E+05 1.60E+06 O.OOE+00 5.29E+06 O.OOE+00 1-130 4.42E+05 1.28E+06 5.11E+05 1.04E+08 1.97E+06 O.OOE+00 9.83E+05 O.OOE+00 1-131 3.17E+08 4.44E+08 2.38E+08 1.29E+11 7.64E+08 O.OOE+00 8.78E+07 O.OOE+00 1-132 1.75E-01 4.59E-01 1.65E-01 1.55E+01 7.23E-01 O.OOE+00 2.OOE-01 O.OOE+00 1-133 4.24E+06 7.20E+06 2.20E+06 1.OOE+09 1.26E+07 O.OOE+00 5.45E+06 O.OOE+00 1-134 2.17E-12 5.75E-12 2.06E-12 9.58E-1 1 9.06E-12 O.OOE+00 7.57E-14 O.OOE+00 1-135 1.37E+04 3.53E+04 1.31 E+04 2.27E+06 5.57E+04 O.OOE+00 3.91 E+04 O.OOE+00 Cs-1 34 1.62E+10 3.82E+10 1.77E+10 0.OOE+00 1.21E+10 4.63E+09 4.75E+08 O.OOE+00 Cs-1 36 6.39E+08 2.51 E+09 1.69E+09 0.OOE+00 1.37E+09 2.16E+08 2.02E+08 O.OOE+00 Cs-137 2.35E+10 3.13E+10 1.09E+10 0.OOE+00 1.06E+10 4.13E+09 4.45E+08 O.OOE+00 Cs-138 2.49E-23 4.79E-23 2.39E-23 0.OOE+00 3.54E-23 4.11E-24 2.17E-26 O.OOE+00 Ba-139 4.93E-09 3.47E-1 2 1.44E-10 0.OOE+00 3.27E-12 2.39E-12 4.40E-08 O.OOE+00 Ba-140 2.79E+06 3.42E+03 1.80E+05 0.OOE+00 1.16E+03 2.30E+03 4.30E+06 O.OOE+00 Ba-141 8.83E-48 6.59E-51 2.95E-49 0.OOE+00 6.12E-51 4.51 E-51 1.88E-53 O.OOE+00 Ba-142 3.01 E-81 3.01 E-84 1.85E-82 0.OOE+00 2.54E-84 2.OOE-84 9.23E-93 O.OOE+00 La-140 4.86E-01 2.39E-01 6.36E-02 0.OOE+00 O.OOE+00 O.OOE+00 1.37E+04 O.OOE+00 La-142 2.02E-12 8.98E-1 3 2.24E-1 3 0.OOE+00 O.OOE+00 O.OOE+00 2.73E-08 O.OOE+00 Ce-141 4.96E+02 3.31 E+02 3.81 E+01 0.OOE+00 1.56E+02 O.OOE+00 9.48E+05 O.OOE+00 Ce-143 4.58E+00 3.34E+03 3.73E-01 0.OOE+00 1.50E+00 O.OOE+00 1.OOE+05 O.OOE+00 Ce-144 4.18E+04 1.73E+04 2.25E+03 0.OOE+00 1.03E+04 O.OOE+00 1.05E+07 O.OOE+00 Pr-143 1.66E+01 6.63E+00 8.27E-01 0.OOE+00 3.86E+00 O.OOE+00 5.47E+04 O.OOE+00 Pr-144 6.65E-55 2.72E-55 3.37E-56 0.OOE+00 1.56E-55 O.OOE+00 7.33E-58 O.OOE+00 Nd-147 5.77E-01 6.27E-01 3.76E-02 0.OOE+00 3.68E-01 O.OOE+00 2.26E+03 O.OOE+00 W-187 7.15E+02 5.83E+02 2.04E+02 0.OOE+00 O.OOE+00 O.OOE+00 1.58E+05 O.OOE+00 Np-239 4.21 E-01 3.97E-02 2.20E-02 0.OOE+00 1.25E-01 O.OOE+00 6.38E+03 O.OOE+OD
- R VALUES IN UNITS OF MREMIYR PER [LCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M 2 -MREM/YR PER tCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE -
Table 5.5-14 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Child PATHWAY = GOAT MILK AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 O.OOE+00 3.20E+03 3.20E+03 3.20E+03 3.20E+03 3.20E+03 3.20E+03 3.20E+03 C-14 2.66E+10 5.32E+09 5.32E+09 5.32E+09 5.32E+09 5.32E+09 5.32E+09 O.OOE+00 Na-24 1.31 E+08 1.31 E+08 1.31 E+08 1.31 E+08 1.31 E+08 1.31 E+08 1.31 E+08 O.OOE+00 P-32 4.59E+10 2.15E+09 1.77E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.27E+09 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 5.68E+03 3.15E+03 8.61 E+02 5.75E+03 3.01 E+05 O.OOE+00 Mn-54 O.OOE+00 1.36E+06 3.62E+05 O.OOE+00 3.81 E+05 O.OOE+00 1.14E+06 0.00E+00 MN-56 O.OOE+00 7.73E-04 1.72E-04 O.OOE+00 9.34E-04 O.OOE+00 .1.12E-01 O.OOE+00 Fe-55 7.93E+05. 4.21 E+05 1.30E+05 O.OOE+00 O.OOE+00 2.38E+05 7.79E+04 O.OOE+00 Fe-59 7.36E+05 1.19E+06 5.93E+05 O.OOE+00 O.OOE+00 3.45E+05 1.24E+06 O.OOE+00 Co-58 O.OOE+00 7.08E+05 2.17E+06 O.OOE+00 O.OOE+00 O.OOE+00 4.13E+06 O.OOE+00 Co-60 O.OOE+00 2.93E+06 8.63E+06 O.OOE+00 O.OOE+00 O.OOE+00 1.62E+07 O.OOE+00 Ni-63 2.22E+09 1.19E+08 7.54E+07 O.OOE+00 O.OOE+00 O.OOE+00 8.OOE+06 O.OOE+00 Ni-65 9.97E-02 9.38E-03 5.48E-03 O.OOE+00 O.OOE+00 O.OOE+00 1.15E+00 O.OOE+00 Cu-64 0.OOE+00 4.29E+03 2.59E+03 O.OOE+00 1.04E+04 0.OOE+00 2.01 E+05 O.OOE+00 Zn-65 3.08E+08 8.66E+08 5.11 E+08 O.OOE+00 5.17E+08 O.OOE+00 1.44E+08 O.OOE+00 Zn-69 5.76E-13 8.32E-13 7.69E-14 O.OOE+00 5.05E-13 O.OOE+00 5.25E-1 I O.OOE+00 Br-83 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 0.0E+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 4.OOE-24 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 0.00+00 O.OOE+00 1.85E-288 O.OOE+O0 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 4.96E+08 3.05E+08 O.OOE+00 0.OOE+00 O.OOE+00 3.19E+07 O.OOE+00 Rb-88 O.OOE+00 4.36E-46 3.03E-46 O.OOE+00 O.OOE+00 O.OOE+00 2.14E-47 O.OOE+00 Rb-89. O.OOE+00 5.92E-54 5.27E-54 O.OOE+00 O.OOE+00 O.OOE+00 5.16E-56 O.OOE+00 Sr-89 6.69E+09 O.OOE+00 1.91 E+08 O.OOE+00 O.OOE+00 O.OOE+00 2.59E+08 O.OOE+00 Sr-90 1.43E+11 O.OOE+00 3.62E+10 O.OOE+00 O.OOE+00 O.OOE+00 1.92E+09 O.OOE+00 Sr-91 1.37E+05 0.001+00 5.17E+03 O.OOE+00 O.OOE00 O.OOE+00 3.03E+05 O.OOE+00 Sr-92 2.30E+00 O.OOE+00 9.22E-02 O.OOE+00 0.001+00 O.OOE+00 4.35E+01 O.OOE+00 Y-90 2.09E-02 O.OOE+00 5.58E-04 O.OOE+00 O.OOE+00 O.OOE+00 5.94E+01 O.OOE+00 Y-91M 1.62E-20 O.OOE+00 8.01 E-22 O.OOE+00 O.OOE+00 O.OOE+00 3.17E-17 O.OOE+00 Y-91 2.25E+03 O.OOE+00 6.OOE+01 O.OOE+00 O.OOE+00 O.OOE+00 2.99E+05 O.OOE+00 Y-92 2.61 E-43 O.OOE+00 7.45E-45 O.OOE+00 O.OOE+00 O.OOE+00 7.53E-39 O.OOE+00 Y-93 6.07E-02 O.OOE+OO 1.67E-03 O.OOE+00 O.OOE+00 O.OOE+00 9.06E+02 O.OOE+00 Zr-95 7.17E+01 1.58E+01 1.40E+01 O.OOE+00 2.26E+01 O.OOE+00 1.64E+04 O.OOE+00 Zr-97 2.39E-10 3.45E-11 2.04E-11 O.OOE+00 4.96E-11 O.OOE+00 5.23E-06 O.OOE+00 Nb-95 1.78E+04 6.93E+03 4.95E+03 0.00+00 6.51 E+03 O.OOE+00 1.28E+07 O.OOE+00 Mo-99 O.OOE+00 6.13E+03 1.52E+03 O.OOE+00 1.31 E+04 O.OOE+00 5.07E+03 O.OOE+00 Tc-99M 1.93E-23 3.79E-23 6.27E-22 O.OOE+00 5.50E-22 1.92E-23 2.15E-20 O.OOE+00 Tc-101 7.21 E-61 7.55E-61 9.57E-60 O.OOE+00 1.29E-59 3.99E-61 2.40E-60 O.OOE+00 Ru-1 03 2.42E+02 O.OOE+00 9.28E+01 O.OOE+00 6.08E+02 O.OOE+00 6.24E+03 O.OOE+00 Ru-105 2.30E-04 O.OOE+00 8.33E-05 O.OOE+00 2.02E-03 O.OOE+00 1.50E-01 O.OOE+00 Ru-106 6.11E+03 O.OOE+00 7.63E+02 O.OOE+00 8.26E+03 0.001+00 9.51 E+04 O.OOE+00 Ag-IIOM 1.41 E+07 9.52E+06 7.61 E+06 O.OOE+00 1.77E+07 O.OOE+00 1.13E+09 O.OOE+00 Te-125M 4.82E+06 1.31 E+06 6.42E+05 1.35E+06 O.OOE+00 O.OOE+00 4.65E+06 O.OOE+00 Te-127M 1.58E+07 4.25E+06 1.87E+06 3.77E+06 4.50E+07 O.OOE+00 1.28E+07 O.OOE+00
I
. PRAIRIE ISLAND NUCLEAR GENERATING PLANT ' H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 134 of 221 Table 5.5-14 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Child PATHWAY = GOAT MILK AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 Te-129M 1.77E+02 1.64E+07 4.77E+01 4.58E+06 3.79E+01 2.54E+06 1.22E+02 5.28E+06 5.03E+02 4.81 E+07 0.OOE+00 0.OOE+00 6.91 E+03 2.OOE+07 0.OOE+00 0.OOE+00 I
Te-129 7.89E- 1 2.20 E-11 1.87E-11 5.63E- 1I 2.31 E-10 0.00E+00 4.91 E-09 0.OOE+00 Te-131M 9.80E+04 3.39E+04 3.61 E+04 6.97E+04 3.28E+05 0.OOE+00 1.37E+06 0.OOE+00 Te-1 31 1.01 E-33 3.06E-34 2.99E-34 7.69E-34 3.04E-33 0.00E+00 5.28E-33 0.OOE+00 Te-132 6.29E+05 2.78E+05 3.36E+05 4.06E+05 2.59E+06 0.OOE+00 2.80E+06 0.OOE+00 1-130 1.03E+06 2.09E+06 1.08E+06 2.30E+08 3.12E+06 0.00E+00 9.77E+05 0.OOE+00 1-131 7.69E+08 7.73E+08 4.39E+08 2.56E+1 I 1.27E+09 0.OOE+00 6.88E+07 0.OOE+00 1-132 4.15E-01 7.62E-01 3.51 E-01 3.54E+01 1.17E+00 0.OOE+00 8.97E-01 0.OOE+00 1-133 1.03E+07 1.27E+07 4.82E+06 2.37E+09 2.12E+07 0.OOE+00 5.14E+06 0.OOE+00 1-134 5.13E-12 9.53 E-12 4.39E-12 2.19E-10 1.46E-11 0.OOE+00 6.32E-12 0.00E+00 1-135 3.24E+04 5.84E+04 2.76E+04 5.17E+06 8.95E+04 0.OOE+00 4.45E+04 0.OOE+00 Cs-1 34 3.74E+10 6.14E+10 1.29E+10 0.00E+00 1.90E+10 6.82E+09 3.31 E+08 0.OOE+00 Cs-1 36 1.44E+09 3.96E+09 2.56E+09 0.OOE+00 2.11 E+09 3.15E+08 1.39E+08 0.00E+00 Cs-1 37 5.66E+10 5.42E+10 8.OOE+09 0.00E+00 1.77E+10 6.35E+09 3.39E+08 0.OOE+00 Cs-1 38 6.05E-23 8.40E-23 5.33E-23 0.OOE+00 5.91 E-23 6.36E-24 3.87E-23 0.OOE+00 Ba-1 39 1.21 E-08 6.47E-12 3.51 E-10 0.OOE+00 5.65E-12 3.80E-12 6.99E-07 0.OOE+00 Ba-140 6.73E+06 5.90E+03 3.93E+05 0.OOE+00 1.92E+03 3.52E+03 3.41 E+06 0.OOE+00 Ba-141 2.17E-47 1.22E-50 7.07E-49 0.OOE+00 1.05E-50 7.14E-50 1.24E-47 0.OOE+00 Ba-142 7.25E-81 5.22E-84 4.05E-82 0.OOE+00 4.22E-84 3.07E-84 9.46E-83 0.OOE+00 La-140 1.16E+00 4.07E-01 1.27E-01 0.OOE+00 0.OOE+00 0.OOE+00 1.13E+04 0.OOE+00 La-142 4.88E-12 1.56E-12 4.87E-1 3 0.OOE+00 0.OOE+00 0.OOE+00 3.08E-07 0.OOE+00 Ce-1 41 1.22E+03 6.09E+02 9.05E+01 0.OOE+00 2.67E+02 0.OOE+00 7.60E+05 0.OOE+00 Ce-1 43 1.13E+01 6.1OE+03 8.84E-01 0.OOE+00 2.56E+00 0.OOE+00 8.93E+04 0.OOE+00 Ce-144 1.03E+05 3.23E+04 5.50E+03 0.OOE+00 1.79E+04 0.OOE+00 8.43E+06 0.OOE+00 Pr-143 4.11E+01 1.23E+01 2.04E+00 0.OOE+00 6.69E+00 0.OOE+00 4.44E+04 0.OOE+00 Pr-1 44 1.65E-54 5.09E-55 8.29E-56 0.00E+00 2.69E-55 0.OOE+00 1.10E-51 0.OOE+00 Nd-147 1.42E+00 1.15E+00 8.88E-02 0.00E+00 6.29E-01 0.OOE+00 1.82E+03 0.OOE+00 W-1 87 1.73E+03 1.03E+03 4.61 E+02 0.OOE+00 0.OOE+00 0.OOE+00 1.44E+05 0.00E+00 Np-239 1.04E+00 7.43E-02 5.23E-02 0.OOE+00 2.15E-01 0.OOE+00 5.50E+03 0.OOE+00
- R VALUES IN UNITS OF MREM/YR PER 1iCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREM/YR PER pICI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4
.~i[ MANUAL (ODCM) REV: 17 I, _ Page 135 of 221 Table 5.5-15 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Infant PATHWAY = GOAT MILK AGE GROUP = INFANT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 0.OOE+00 4.86E+03 4.86E+03 4.86E+03 4.86E+03 4.86E+03 4.86E+03 4.86E+03r C-1 4 5.21 E+1 0 1.11E+10 1.11E+10 1.11E+10 1.11E+10 1.11E+10 1.11E+10 0.OOE+00 Na-24 2.28E+08 2.28E+08 2.28E+08 2.28E+08 2.28E+08 2.28E+08 2.28E+08 0.OOE+00 P-32 9.47E+10 5.57E+09 3.87E+09 0.OOE+00 0.OOE+00 0.OOE+00 1.28E+09 O.OOE+00 Cr-51 0.00E+00 0.OOE+00 8.99E+03 5.87E+03 1.28E+03 1.14E+04 2.62E+05 0.OOE+00 Mn-54 0.00E+00 2.53E+06 5.73E+05 0.00E+00 5.60E+05 0.OOE+00 9.28E+05 O.OOE+00 MN-56 0.OOE+00 1.89E-03 3.26E-04 0.OOE+00 1.63E-03 0.OOE+00 1.72E-01 0.OOE+00 Fe-55 9.59E+05 6.19E+05 1.66E+05 0.OOE+00 0.OOE+00 3.03E+05 7.86E+04 0.OOE+00 Fe-59 1.37E+06 2.40E+06 9.46E+05 0.OOE+00 0.OOE+00 7.09E+05 I.15E+06 0.OOE+00 Co-58 0.OOE+00 1.42E+06 3.51 E+06 0.OOE+00 0.OOE+00 0.OOE+00 3.53E+06 0.OOE+00 Co-60 0.OOE+00 5.97E+06 1.41 E+07 0.OOE+00 0.00E+00 0.OOE+00 1.42E+07 0.OOE+00 Ni-63 2.61 E+09 1.62E+08 9.07E+07 0.OOE+00 O.OOE+00 0.OOE+00 8.04E+06 0.OOE+00 Ni-65 2.11E-01 2.39E-02 '1.09E-02 0.OOE+00 0.00E+00 0.OOE+00 1.82E+00 0.00E+00 Cu-64 0.OOE+00 1.07E+04 4.93E+03 0.OOE+00 1.80E+04 0.OOE+00 2.19E+05 0.OOE+00 Zn-65 3.01 E+08 1.42E+09 6.55E+08 0.OOE+00 6.88E+08 0.OOE+00 1.20E+09 0.OOE+00 Zn-69 1.23E-12 2.21E-12 1.64E-13 0.OOE+00 9.18E-13 0.OOE+00 -I80E-10 0.O0E+00 Br-83 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Br-84 0.OOE+00 0.OOE+00 7.72E-24 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Br-85 0.OOE+00 0.OOE+00 3.94E-288 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Rb-86 0.OOE+00 1.26E+09 6.22E+08 0.OOE+00 0.OOE+00 0.OOE+00 3.22E+07 0.OOE+00 Rb-88 0.OOE+00 1.14E-45 6.26E-46 0.OOE+00 0.OOE+00 0.OOE+00 1.11 E-45 0.OOE+00 Rb-89 0.OOE+00 '.45E-53 9.97E-54 0.OOE+00 0.OOE+00 0.OOE+00 4.93E-54 0.OOE+00 Sr-89 1.27E+10 0.OOE+00 3.65E+08 0.OOE+00 0.OOE+00 0.OOE+00 2.62E+08 0.OOE+00 Sr-90 1.55E+11 0.OOE+00 3.95E+10 0.OOE+00 0.OOE+00 0.OOE+00 1.94E+09 0.OOE+00 Sr-91 2.85E+05 O.0OE+00 1.03E+04 0.OOE+00 0.OOE+00 0.00E+00. 3.38E+05 0.OOE+00 Sr-92 4.89E+00 O.OOE+00 1.82E-01 0.OOE+00 0.OOE+00 0.OOE+00 5.27E+01 0.OOE+00 Y-90 4.41 E-02 0.OOE+00 1.18E-03 0.OOE+00 0.OOE+00 0.OOE+00 6.09E+01 0.OOE+00 Y-91M *3.43E-20 0.OOE+00 1.17E-21 O.OOE+00 0.OOE+00 0.OOE+00 1.14E-16 0.OOE+00 Y-91 4.25E+03 O.OOE+00 1.12E+02 O.00E+00 O.OOE+00 O.00E+00 3.02E+05 0.OOE+00 Y-92 5.54E-43 0.OOE+00 1.56E-44 0.OOE+00 0.OOE+00 0.OOE+00 1.06E-38 0.OOE+00 Y-93 1.29E-01 0.OOE+00 3.53E-03 0.OOE+00 0.OOE+00 O.00E+00 1.02E+03 0.OOE+00 Zr-95 1.27E+02 3.10E+01 2.20E+01 0.OOE+00 3.34E+01 0.00E+00 1.55E+04 0.OOE+00 Zr-97 5.06E-10 8.68E-11 3.96E-11 0.OOE+00 8.75E- 1 0.OOE+00 5.54E-06 0.OOE+00 Nb-95 3.32E+04 1.37E+04 7.91 E+03 0.OOE+00 9.81 E+03 0.OOE+00 1.15E+07 O.OOE+00 Mo-99 0.OOE+00 1.57E+04 3.05E+03 0.OOE+00 2.34E+04 0.OOE+00 5.16E+03 0.OOE+00 Tc-99M 4.02E-23 8.28E-23 1.07E-21 0.OOE+00 8.91 E-22 4.33E-23 2.40E-20 O.00E+00 Tc-101 1.53E-60 1.93E-60 1.91 E-59 0.OOE+00 2.29E-59 1.05E-60 3.28E-58 0.OOE+00 Ru-I 03 4.89E+02 0.OOE+00 1.64E+02 0.OOE+00 1.02E+03 0.OOE+00 5.95E+03 0.00E+00 Ru-1 05 4.84E-04 0.OOE+00 1.61 E-04 0.OOE+00 3.56E-03 0.OOE+00 1.93E-01 0.OOE+00 Ru-106 1.26E+04 0.OOE+00 1.57E+03 0.OOE+00 1.49E+04 0.OOE+00 9.56E+04 0.OOE+00 Ag-1I0M 2.61 E+07 1.90E+07 1.26E+07 0.OOE+00 2.72E+07 0.OOE+00 9.86E+08 0.OOE+00 Te-125M 9.85E+06 3.29E+06 1.33E+06 3.31 E+06 0.OOE+00 0.OOE+00 4.69E+06 0.OOE+00 Te-1 27M 3.19E+07 1.07E+07 3.86E+06 9.22E+06 7.86E+07 0.OOE+00 1.29E+07 0.OOE+00
PRAIR.IE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE 4" 2NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
__________________ Page 136 of 221 Table 5.5-15 R Values for the Prairie Island Nuclear Generating Plant*
- Goat Milk, Infant PATHWAY = GOAT MILK AGE GROUP = INFANT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-1 27 3.75E+02 1.26E+04 8.07E+01 3.06E+02 9.16E+02 0.OOE+00 7.89E+03 0.00E+00 Te-129M 3.36E+07 1.15E+07 5.18E+06 1.29E+07 8.41 E+07 0.00E+00 2.01 E+07 0.OOE+00 Te-129 1.67E-10 5.77 E- 1 3.90E- 1 1.40E-10 4.16E-10 0.OOE+00 1.34E-08 0.00E+00 Te-131M 2.07E+05 8.33E+02 6.87E+04 1.69E+05 5.73E+05 0.OOE+00 1.40E+06 0.00E+00 Te-131 2.13E-33 7.87E-34 5.95E-34 1.90E-33 5.45E-33 0.00E+00 8.61 E-32 0.OOE+00 Te-132 1.30E+06 6.42E+05 5.99E+05 9.47E+05 4.01 E+06 0.OOE+00 2.37E+06 0.00E+00 1-130 2.12E+06 4.67E+06 1.88E+06 5.24E+08 5.13E+06 0.OOE+00 1.OOE+06 0.00E+00 1-131 1.60E+09 1.89E+09 8.31 E+08 6.21 E+11 2.21 E+09 0.OOE+00 6.75E+07 0.OOE+00 1-132 8.61 E-01 1.75E+00 6.22E-01 8.19E+01 1.95E+00 0.00E+00 1.42E+00 0.OOE+00 1-133 2.18E+07 3.17E+07 9.28E+06 5.76E+09 3.73E+07 0.OOE+00 5.36E+06 0.00E+00 1-134 1.06E-11 2.18E-1I 7.49E-12 5.08 E-10 2.44E- 1 0.OOE+00 2.25E- 1 0.OOE+00 1-135 6.75E+04 1.34E+05 4.89E+04 1.20E+07 1.50E+05 0.OOE+00 4.86E+04 0.OOE+00 Cs-1 34 6.02E+10 1.12E+1I 1.13E+10 0.OOE+00 2.89E+10 1.19E+10 3.05E+08 0.OOE+00 Cs-136 2.82E+09 8.28E+09 3.09E+09 0.OOE+00 3.30E+09 6.75E+08 1.26E+08 0.OOE+00 Cs-137 9.04E+10 1.06E+1I 7.50E+09 0.OOE+00 2.84 E+1 0 1.15E+10 3.31 E+08 0.00E+00 Cs-1 38 1.28E-22 2.07E-22 9.81 E-23 0.00E+00 1.03E-22 1.61 E-23 3.31 E-22 O.00E+00 Ba-1 39 2.58E-08 1.71E-11 7.46E-10 0.OOE+00 1.03E-11 1.04E-11 1.63E-06 0.00E+00 Ba-140 1.39E+07 1.39E+04 7.14E+05 0.OOE+00 3.29E+03 8.51 E+03 3.40E+06 0.00E+00 Ba-141 4.61 E-47 3.16E-50 1.45E-48 0.OOE+00 1.90E-50 1.92E-50 5.63E-46 0.00E+00 Ba-142 1.53E-80 1.27E-83 7.51 E-82 0.OOE+00 7.31 E-84 7.68E-84 6.30E-80 0.OOE+00 La-1 40 2.43E+00 9.59E-01 2.47E-01 0.OOE+00 0.OOE+00 0.OOE+00 1.13E+04 0.OOE+00 La-1 42 1.02E-11 3.76E-12 9.01 E-13 0.OOE+00 0.OOE+00 0.OOE+00 6.39E-07 0.OOE+00 Ce-141 2.42E+03 1.48E+03 1.74E+02 0.OOE+00 4.56E+02 0.00E+00 7.63E+05 0.OOE+00 Ce-143 2.38E+01 1.58E+04 1.80E+00 0.OOE+00 4.60E+00 0.00E+00 9.22E+04 0.00E+00 Ce-144 1.48E+05 6.05E+04 8.28E+03 0.OOE+00 2.44E+04 0.OOE+00 8.48E+06 0.00E+00 Pr-143 8.51 E+01 3.18E+01 4.22E+00 0.OOE+00 1.18E+01 0.OOE+00 4.49E+04 0.00E+00 Pr-144 3.50E-54 1.35E-54 1.76E-55 0.OOE+00 4.90E-55 0.00E+00 6.29E-50 0.OOE+00 Nd-147 2.81 E+00 2.88E+00 1.77E-01 0.OOE+00 1.11 E+00 0.OOE+00 1.83E+03 0.OOE+00 W-187 3.65E+03 2.54E+03 8.77E+02 0.OOE+00 0.OOE+00 0.OOE+00 1.49E+05 0.00E+00 Np-239 2.19E+00 1.96E-01 1.11E-01 0.OOE+00 3.90E-01 0.OOE+00 5.66E+03 0.OOE+00
- R VALUES IN UNITS OF MREMYR PER iCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMYR PER pCI/SEC FOR ALL OTHERS.
'j
PRAIRIE ISLAND NUCLEAR GENERATING PLANT' H PROCEDURE NUMBER:
) LI sOFFSITE DOSE CALCULATION H4 EU 5 sMANUAL (ODCM) REV: 17 Table 5.5-16 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Adult PATHWAY = INHALATION AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 O.OOE+OO 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 O.OOE+OO Na-24 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 O.OOE+OO P-32 1.32E+06 7.71 E+04 5.01 E+04 O.OOE+OO O.OOE+OO O.OOE+O0 8.64E+04 O.OOE+OO Cr-51 O.OOE+OO O.OOE+OO 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 O.OOE+OO Mn-54 O.OOE+OO 3.96E+04 6.30E+03 O.OOE+OO 9.84E+03 1.40E+06 7.74E+04 O.OOE+OO MN-56 O.OOE+OO 1.24E+00 1.83E-01 O.OOE+OO 1.30E+00 9.44E+03 2.02E+04 O.OOE+OO Fe-55 2.46E+04 1.70E+04 3.94E+03 O.OOE+OO O.OOE+OO 7.21 E+04 6.03E+03 O.OOE+OO Fe-59 1.18E+04 2.78E+04 1.06E+04 O.OOE+OO O.OOE+OO 1.02E+06 1.88E+05 O.OOE+O0 Co-58 O.OOE+OO 1.58E+03 2.07E+03 O.OOE+OO O.OOE+OO 9.28E+05 1.06E+05 O.OOE+OO Co-60 O.OOE+OO 1.15E+04 1.48E+04 O.OOE+OO O.OOE+OO 5.97E+06 2.85E+05 O.OOE+OO Ni-63 4.32E+05 3.14E+04 1.45E+04 O.OOE+OO O.OOE+OO 1.78E+05 1.34E+04 O.OOE+OO Ni-65 1.54E+00 2.10E-01 9.12E-02 O.OOE+OO O.OOE+OO 5.60E+03 1.23E+04 O.OOE+OO Cu-64 O.OOE+OO 1.46E+00 6.15E-O1 O.OOE+O0 4.62E+00 6.78E+03 4.90E+04 O.OOE+OO Zn-65 3.24E+04 1.03E+05 4.66E+04 O.OOE+OQ 6.90E+04 8.64E+05 5.34E+04 O.OOE+OO Zn-69 3.38E-02 6.51 E-02 4.52E-03 O.OOE+OO 4.22E-02 9.20E+02 1.63E+01 O.OOE+OO Br-83 O.OOE+OO O.OOE+OO 2.41 E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.32E+02 O.OOE+OO Br-84 O.OOE+00 O.OOE+OO 3.13E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.64E-03 O.OOE+OO Br-85 O.OOE+O0 O.OOE+OO 1.28E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Rb-86 O.OOE+OO 1.35E+05 5.90E+04 O.OOE+OO O.OOE+O0 O.OOE+OO 1.66E+04 O.OOE+OO Rb-88 O.OOE+OO 3.87E+02 1.93E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.34E-09 O.OOE+OO Rb-89 O.OOE+OO 2.56E+02 1.70E+02 O.OOE+O0 O.OOE+OO O.OOE+O0 9.28E-12 O.OOE+OO Sr-89 3.04E+05 O.OOE+00 8.72E+03 O.OOE+OO O.OOE+OO 1.40E+06 3.50E+05 O.OOE+OO Sr-90 9.92E+07 O.OOE+OO 6.10E+06 O.OOE+OO O.OOE+OO 9.60E+06 7.22E+05 O.OOE+OO Sr-91 6.19E+01 O.OOE+OO 2.50E+OO O.OOE+OO O.OOE+OO 3.65E+04 1.91 E+05 O.OOE+OO Sr-92 6.74E+OO O.OOE+OO 2.91 E-01 O.OOE+OO O.OOE+OO 1.65E+04 4.30E+04 O.OOE+OO Y-90 2.09E+03 O.OOE+OO 5.61 E+01 O.OOE+OO O.OOE+OO 1.70E+05 5.06E+05 O.OOE+OQ Y-91 M 2.61 E-01 O.OOE+OO 1.02E-02 O.OOE+OO O.OOE+OO 1.92E+03 1.33E+OO O.OOE+OO Y-91 4.62E+05 O.OOE+OO 1.24E+04 O.OOE+OO O.OOE+OO 1.70E+06 3.85E+05 O.OOE+OO Y-92 1.03E+01 O.OOE+OO 3.02E-01 O.OOE+OO O.OOE+OO 1.57E+04 7.35E+04 O.OOE+OO Y-93 9.44E+01 O.OOE+OO 2.61 E+OO O.OOE+OO O.OOE+OO 4.85E+04 4.22E+05 O.OOE+OO Zr-95 1.07E+05 3.44E+04 2.33E+04 O.OOE+OO 5.42E+04 1.77E+06 1.50E+05 O.OOE+OO Zr-97 9.68E+01 1.96E+01 9.04E+OO O.OOE+OO 2.97E+01 7.87E+04 5.23E+05 O.OOE+OO Nb-95 1.41 E+04 7.82E+03 4.21 E+03 O.OOE+OO 7.74E+03 5.05E+05 1.04E+05 O.OOE+OO Mo-99 O.OOE+OO 1.21 E+02 2.30E+01 O.OOE+OO 2.91 E+02 9.12E+04 2.48E+05 O.OOE+OO Tc-99M 1.03E-03 2.91 E-03 3.70E-02 O.OOE+OO 4.42E-02 7.64E+02 4.16E+03 O.OOE+OO Tc-101 4.18E-05 6.02E-05 5.90E-04 O.OOE+OO 1.08E-03 3.99E+02 1.09E-11 O.OOE+OO Ru-103 1.53E+03 O.OOE+OO 6.58E+02 O.OOE+OO 5.83E+03 5.05E+05 1.1OE+05 O.OOE+OO Ru-105 7.90E-01 O.OOE+OO 3.11E-01 O.OOE+OO 1.02E+00 1.10E+04 4.82E+04 O.OOE+OO Ru-106 6.91 E+04 O.OOE+OO 8.72E+03 O.OOE+OO 1.34E+05 9.36E+06 9.12E+05 O.OOE+OO Ag-110M 1.08E+04 1.OOE+04 5.94E+03 O.OOE+OO 1.97E+04 4.63E+06 3.02E+05 O.OOE+OO Te-125M 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 O.OOE+OO Te-127M 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 O.OOE+OO
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE PLANT GENERATING NUCLEAR ISLAND PRAIRIE HPROCEDURE~~~~~~
NUMBER:
OFFSITE DOSE CALCULATION H4 X X U MANUAL (ODCM) REV: 17 DC M)
MANUAL (O ~~~~Page 138 of 221 Table 5.5-16 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Adult PATHWAY = INHALATION AGE GROUP = ADULT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 1.40E+00 6.42E-01 3.10E-01 1.06E+00 5.10E+00 6.51 E+03 5.74E+04 0.OOE+00 Te-129M 9.76E+03 4.67E+03 1.57E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 O.OOE+00 Te-129 4.98E-02 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 O.0OE+00 Te-131M 6.99E+01 4.36E+01 2.90E-02 5.50E+01 3.09E+02 1.46E+05 5.56E+05 0.0OE+00 Te-131 1.11 E-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 0.OOE+00 Te-132 2.60E+02 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.1OE+05 0.OOE+00 1-130 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 0.OE+00 7.69E+03 0.OOE+00 1-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 0.00E+00 6.28E+03 O.OOE+00 1-132 1.16E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 0.OOE+00 4.06E+02 0.OOE+00 1-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 0.OOE+00 8.88E+03 O.OOE+00 1-134 6.44E+02 1.73E+03 6.15E+02 2.98E+04 2.75E+03 O.OOE+00 1.01E+00 O.OOE+00 1-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.11 E+04 0.00E+00 5.25E+03 0.OOE+00 Cs-134 3.73E+05 8.48E+05 7.28E+05 0.OOE+00 2.87E+05 9.76E+04 1.04E+04 0.OOE+00 Cs-136 3.90E+04 1.46E+05 1.10E+05 O.OOE+00 8.56E+04 1.20E+04 1.17E+04 0.OOE+00 Cs-137 4.78E+05 6.21 E+05 4.28E+05 0.OE+00 2.22E+05 7.52E+04 8.40E+03 O.OOE+00 Cs-138 3.31 E02 6.21 E+02 3.24E+02 0.OOE+00 4.80E+02 4.86E+01 1.86E-03 0.OOE+00 Ba-1 39 9.36E-01 6.66E-04 2.74E-02 0.OOE+00 6.22E-04 3.76E+03 8.96E+02 0.OOE+00 Ba-140 3.90E+04 4.90E+01 2.57E+03 0.OOE+00 1.67E+01 1.27E+06 2.18E+05 0.OOE+00 Ba-141 1.OOE-01 7.53E-05 3.36E-03 O.0OE+00 7.OOE-05 1.94E+03 1.16E-07 0.00E+00 Ba-142 2.63E-02 2.70E-05 1.66E-03 0.OOE+00 2.29E-05 1.19E+03 1.57E-16 0.OOE+00 La-140 3.44E+02 1.74E+02 4.58E+01 0.OOE+00 0.00E+00 1.36E+05 4.58E+05 0.OOE+00 La-142 6.83E-01 3.10E-01 7.72E-02 O.OOE+00 O.OOE+00 6.33E+03 2.11E+05 O.OOE+00 Ce-141 1.99E+04 1.35E+04 1.53E+03 0.OOE+00 6.26E+03 3.62E+05 1.20E+05 0.OOE+00 Ce-143 1.86E+02 1.38E+02 1.53E+01 0.OOE+00 6.08E+01 7.98E+04 2.26E+05 0.OOE+00 Ce-144 3.43E+06 1.43E+06 1.84E+05 0.OOE+00 8.48E+05 7.78E+06 8.16E+05 0.OOE+00 Pr-143 9.36E+03 3.75E+03 4.64E+02 0.OOE+00 2.16E+03 2.81 E+05 2.OOE+05 0.OOE+00 Pr-144 3.01 E-02 1.25E-02 1.53E-03 0.OOE+00 7.05E-03 1.02E+03 2.15E-08 O.OOE+00 Nd-147 5.27E+03 6.10E+03 3.65E+02 0.OOE+00 3.56E+03 2.21 E+05 1.73E+05 0.OOE+00 W-187 8.48E+00 7.08E+00 2.48E+00 0.OOE+00 0.OOE+00 2.90E+04 1.55E+05 0.OE+00 Np-239 2.30E+02 2.26E+01 1.24E+01 0.OOE+00 7.OOE+01 3.76E+04 1.19E+05 0.OOE+00
- R VALUES IN UNITS OF MREM/YR PER plCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREM/YR PER iLCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-17 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Teen PATHWAY = INHALATION AGE GROUP ; TEEN NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 0.00E+00 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 C-14 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 0.00E+00 Na-24 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 0.00E+00 P-32 1.89E+06 1.10E+05 7.16E+04 1.27E+03 0.00E+00 0.00E+00 9.28E+04 0.OOE+00 Cr-51 0.00E+00 0.00E+00 1.35E+02 4.87E+03 3.07E+01 2.10E+04 3.00E+03 0.00E+00 Mn-54 0.OOE+00 5.11 E+04 8.40E+03 1.38E+04 1.27E+04 1.98E+06 6.68E+04 0.00E+00 MN-56 0.00E+00 1.70E+00 2.52E-01 0.00E+00 1.79E+00 1.52E+04 5.74E+04 0.00E+00 Fe-55 3.34E+04 2.38E+04 5.54E+03 7.50E+01 0.OOE+00 1.24E+05 6.39E+03 0.00E+00 Fe-59 8.72E+03 3.70E+04 1.43E+04 0.00E+00 0.00E+00 1.53E+06 1.78E+05 0.00E+00 Co-58 0.00E+00 2.07E+03 2.78E+03 0.00E+00 0.00E+00 1.34E+06 9.52E+04 0.00E+00 Co-60 0.00E+00 1.51 E+04 1.98E+04 0.OOE+00 0.00E+00 8.72E+06 2.59E+05 O.OOE+00 Ni-63 5.80E+05 4.34E+04 1.98E+04 0.00E+00 0.00E+00 3.07E+05 1.42E+04 0.00E+00 Ni-65 2.18E+00 2.93E-01 1.27E-01 0.OOE+00 0.00E+00 9.36E+03 3.67E+04 0.00E+00 Cu-64 0.00E+00 2.03E+00 8.48E-01 0.OOE+00 6.41E+00 1.11E+04 6.14E+04 0.OOE+00 Zn-65 3.86E+04 1.34E+05 6.24E+04 0.OOE+00 8.64E+04 1.24E+06 4.66E+04 0.OOE+00 Zn-69 4.83E-02 9.20E-02 6.46E-03 0.OOE+00 6.02E-02 1.58E+03 2.85E+02 0.00E+00 Br-83 0.OOE+00 0.00E+00 3.44E+02 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 Br-84 0.OOE+00 0.OOE+00 4.33E+02 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 Br-85 0.00E+00 0.00E+00 1.83E+01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Rb-86 0.OOE+00 1.90E+05 8.40E+04 0.00E+00 0.00E+00 0.00E+00 1.77E+04 0.00E+00 Rb-88 0.00E+00 5.46E+02 2.72E+02 0.00E+00 0.00E+00 0.00E+00 2.92E-05 0.00E+00 Rb-89, 0.OOE+00 3.52E+02 2.33E+02 0.00E+00 0.OOE+00 0.00E+00 3.38E-07 0.OOE+00 Sr-89 4.34E+05 0.00E+00 1.25E+04 0.00E+00 0.00E+00 2.42E+06 3.71 E+05 0.00E+00 Sr-90 1.08E+08 0.00E+00 6.68E+06 0.00E+00 0.OOE+00 1.65E+07 7.65E+05 0.00E+00 Sr-91 8.80E+01 0.0OE+00 3.51 E+00 0.00E+00 0.00E+00 6.07E+04 2.59E+05 0.00E+00 Sr-92 9.52E+00 0.00E+00 4.06E-01 0.00E+00 0.00E+00 2.74E+04 1.19E+05 0.00E+00 Y-90 2.98E+03 0.00E+00 8.00E+01 0.00E+00 0.OOE+00 2.93E+05 5.59E+05 0.00E+00 Y-91 M 3.70E-01 0.00E+00 1.42E-02 0.00E+00 0.00E+00 3.20E+03 3.02E+01 0.00E+00 Y-91 6.61 E+05 0.00E+00 1.77E+04 0.00E+00 0.00E+00 2.94E+06 4.09E+05 0.00E+00 Y-92 1.47E+01 0.00E+00 4.29E-01 0.00E+00 0.00E+00 2.68E+04 1.65E+05 0.00E+00 Y-93 1.35E+02 0.00E+00 3.72E+00 -0.00E+00 0.00E+00 8.32E+04 5.79E+05 0.00E+00 Zr-95 1.46E+05 4.58E+04 3.152+04 - 0.00E+00 6.74E+04 2.69E+06 1.49E+05 0.OOE+00 Zr-97 1.38E+02 2.72E+01 1.26E+01 0.00E+00 4.12E+01 1.30E+05 6.30E+05 0.00E+00 Nb-95 1.86E+04 1.03E+04 5.66E+03 0.00E+00 1.OOE+04 7.51 E+05 9.68E+04 0.00E+00 Mo-99 0.00E+00 1.69E+02 3.22E+01 0.00E+00 4.11 E+02 1.54E+05 2.69E+05 0.00E+00 Tc-99M 1.38E-03 3.86E-03 4.99E-02 0.00E+00 5.76E-02 1.15E+03 6.13E+03 0.00E+00 Tc-101 5.92E-05 8.40E-05 8.24E-04 0.00E+00 1.52E-03 6.67E+02 8.72E-07 0.OOE+00 Ru-103 2.10E+03 0.00E+00 8.96E+02 0.00E+00 7.43E+03 7.83E+05 1.09E+05 0.00E+00 Ru-105 1.12E+00 0.00E+00 4.34E-01 0.00E+00 1.41 E+00 1.82E+04 9.04E+04 0.00E+00 Ru-106 9.84E+04 0.00E+00 1.24E+04 0.00E+00 1.90E+05 1.61E+07 9.60E+05 0.00E+00 Ag-110M 1.38E+04 1.31 E+04 7.99E+03 0.00E+00 2.50E+04 6.75E+06 2.73E+05 0.00E+00 Te-125M 4.88E+03 2.24E+03 6.67E+02 1.40E+03 0.00E+00 5.36E+05 7.50E+04 0.00E+00 Te-127M 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 0.00E+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-17 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Teen PATHWAY = INHALATION AGE GROUP = TEEN NUCLIDE BONE LIVE R T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 2.01 E+00 9.12E-01 4.42E-01 1.42E+00 7.28E+00 1.12E+04 8.08E+04 O.OOE+00 Te-129M 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 O.OOE+00 Te-129 7.1 OE-02 3.38E-02 1.76E-02 5.1 8E-02 2.66E-01 3.30E+03 1.62E+03 O.OOE+00 Te-131M 9.84E+01 6.01 E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21 E+05 O.OOE+00 Te-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51 E+01 O.OOE+00 Te-132 3.60E+02 2.90E+04 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 O.OOE+00 1-130 6.24E+03 1.79E+04 7.17E+03 1.49E+06 2.75E+04 O.OOE+00 9.12E+03 O.OOE+00 1-131 3.54E+04 4.91 E+04 2.64E+04 1.46E+07 8.40E+04 O.OOE+00 6.49E+03 O.OOE+00 1-132 1.59E+03 4.38E+03 1.58E+03 1.51 E+05 6.92E+03 O.OOE+00 1.27E+03 O.OOE+00 1-133 1.22E+04 1.89E+04 6.22E+03 2.92E+06 3.59E+04 O.OOE+00 1.03E+04 O.OOE+00 1-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 O.OOE+00 2.04E+01 O.OOE+00 1-135 3.70E+03 9.44E+03 3.49E+03 6.21 E+05 1.49E+04 O.OOE+00 6.95E+03 O.OOE+00 Cs-1 34 5.02E+05 1.13E+06 5.49E+05 0.OOE+00 3.75E+05 1.46E+05 9.76E+03 O.OOE+00 Cs-1 36 5.15E+04 1.94E+05 1.37E+05 0.OOE+00 1.1OE+05 1.78E+04 1.09E+04 O.OOE+00 Cs-1 37 6.70E+05 8.48E+05 3.11 E+05 0.OOE+00 3.04E+05 1.21 E+05 8.48E+03 O.OOE+00 Cs-I 38 4.66E+02 8.56E+02 4.46E+02 0.OOE+00 6.62E+02 7.87E+01 2.70E-01 O.OOE+00 Ba-1 39 1.34E+00 9.44E-04 3.90E-02 0.OOE+00 8.88E-04 6.46E+03 6.45E+03 O.OOE+00 Ba-1 40 5.47E+04 6.70E+01 3.52E+03 0.OOE+00 2.28E+01 2.03E+06 2.29E+05 O.OOE+00 Ba-141 1.42E-01 1.06E-04 4.74E-03 0.OOE+00 9.84E-05 3.29E+03 7.46E-14 O.OOE+00 Ba-1 42 3.70E-02 3.70E-05 2.27E-03 0.OOE+00 3.14E-05 1.91 E+03 4.79E-10 O.OOE+00 La-140 4.79E+02 2.36E+02 6.26E+01 0.OOE+00 O.OOE+00 2.14E+05 4.87E+05 O.OOE+00 La-142 9.60E-01 4.25E-01 1.06E-01 0.OOE+00 O.OOE+00 1.02E+04 1.20E+04 O.OOE+00 Ce-141 2.84E+04 1.90E+04 2.17E+03 0.00E+00 8.88E+03 6.14E+05 1.26E+05 O.OOE+00 Ce-143 2.66E+02 1.94E+02 2.16E+01 0.OOE+00 8.64E+01 1.30E+05 2.55E+05 O.OOE+00 Ce-1 44 4.89E+06 2.02E+06 2.62E+05 0.OOE+00 1.21 E+06 1.34E+07 8.64E+05 O.OOE+OO Pr-1 43 1.34E+04 5.31 E+03 6.62E+02 0.OOE+00 3.09E+03 4.83E+05 2.14E+05 O.OOE+00 Pr-1 44 4.30E-02 1.76E-02 2.18E-03 0.OOE+00 1.01 E-02 1.75E+03 2.35E-04 O.OOE+00 Nd-147 7.86E+03 8.56E+03 5.13E+02 0.OOE+00 5.02E+03 3.72E+05 1.82E+05 O.OOE+00 W-187 1.20E+01 9.76E+00 3.43E+00 0.OOE+00 O.OOE+00 4.74E+04 1.77E+05 O.OOE+00 Np-239 3.38E+02 3.19E+01 1.77E+01 0.OOE+00 1.OOE+02 6.49E+04 1.32E+05 O.OOE+00
- R VALUES IN UNITS OF MREMIYR PER ~iCI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREM/YR PER pCI/SEC FOR ALL OTHERS.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-18 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Child PATHWAY = INHALATION AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN I H-3 O.OOE+00 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 O.OOE+00 Na-24 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 O.OOE+00 P-32 2.60E+06 1.14E+05 9.88E+04 O.OOE+00 O.OOE+00 O.OOE+00 4.22E+04 O.OOE+00 Cr-51 O.OOE+Ob O.OOE+00 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 O.OOE+00 Mn-54 O.OOE+00 4.29E+04 9.51 E+03 0.OOE+00 1.OOE+04 1.58E+06 2.29E+04 O.OOE+00 MN-56 O.OOE+00 1.66E+00 3.12E-01 O.OOE+00 1.67E+00 1.31 E+04 1.23E+05 O.OOE+00 Fe-55 4.74E+04 2.52E+04 7.77E+03 O.OOE+00 O.OOE+00 1. 1 E+05 2.87E+05 O.OOE+O0 Fe-59 2.07E+04 3.34E+04 1.67E+04 O.OOE+00 O.OOE+00 1.27E+06 7.07E+04 O.OOE+O0 Co-58 O.OOE+00 1.77E+03 3.16E+03 O.OOE+00 O.OOE+00 1.11 E+06 3.44E+04 O.OOE+00 Co-60 O.OOE+00 1.31 E+04 2.26E+04 O.OOE+00 O.OOE+00 7.07E+06 9.62E+04 O.OOE+00 Ni-63 8.21 E+05 4.63E+04 2.80E+04 O.OOE+00 O.OOE+00 2.75E+05 6.33E+03 O.OOE+00 Ni-65 2.99E+O0 2.96E-01 1.64E-01 O.OOE+00 O.OOE+00 8.18E+03 8.40E+04 O.OOE+00 Cu-64 O.OOE+00 1.99E+00 1.07E+00 O.OOE+00 6.03E+00 9.58E+03 3.67E+04 O.OOE+00 Zn-65 4.26E+04 1.13E+05 7.03E+04 O.OOE+00 7.14E+04 9.95E+05 1.63E+04 O.OOE+00 Zn-69 6.70E-02 9.66E-02 8.92E-03 O.OOE+00 5.85E-02 1.42E+03 1.02E+04 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 4.74E+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 5.48E+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 2.53E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.98E+05 1.14E+05 O.OOE+00 O.OOE+00 O.OOE+00 7.99E+03 O.OOE+00 Rb-88 O.OOE+00 5.62E+02 3.66E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.72E+01 O.OOE+00 Rb-89 O.OOE+00 3.45E+02 2.90E+02 O.OOE+00 O.OOE+00 O.OOE+00 1.89E+00 O.OOE+00 Sr-89 5.99E+05 O.OOE+00 1.72E+04 O.OOE+00 O.OOE+00 2.16E+06 1.67E+05 O.OOE+00 Sr-90 1.01 E+08 O.OOE+00 6.44E+06 O.OOE+O0 O.OOE+00 1.48E+07 3.43E+05 O.OOE+00 Sr-91 1.21 E+02 O.OOE+00 4.59E+00 O.OOE+00 O.OOE+00 5.33E+04 1.74E+05 O.OOE+00 Sr-92 1.31 E+01 O.OOE+00 5.25E-01 O.OOE+00 O.OOE+00 2.40E+04 2.42E+05 O.OOE+00 Y-90 4. 1 E+03 O.OOE+00 1.11E+02 O.OOE+00 O.OOE+00 2.62E+05 2.68E+05 O.OOE+00 Y-91M 5.07E-01 O.OOE+00 1.84E-02 O.OOE+00 O.OOE+00 2.81 E+03 1.72E+03 O.OOE+00 Y-91 9.14E+05 O.OOE+00 2.44E+04 O.OOE+O0 O.OOE+00 2.63E+06 1.84E+05 O.OOE+00 Y-92 2.04E+01 O.OOE+00 5.81 E-01 O.OOE+00 O.OOE+00 2.39E+04 2.39E+05 O.OOE+00 Y-93 1.86E+02 O.OOE+00 5.1 E+00 O.OOE+00 O.OOE+00 7.44E+04 3.89E+05 O.OOE+00 Zr-95 1.90E+05 4.18E+04 3.70E+04 O.OOE+00 5.96E+04 2.23E+06 6. 1 E+04 O.OOE+00 Zr-97 1.88E+02 2.72E+01 1.60E+01 O.OOE+00 3.89E+01 1.13E+05 3.51 E+05 O.OOE+00 Nb-95 2.35E+04 9.18E+03 6.55E+03 O.OOE+00 8.62E+03 6.14E+05 3.70E+04 O.OOE+00 Mo-99 O.OOE+00 1.72E+02 4.26E+01 O.OOE+00 3.92E+02 1.35E+05 1.27E+05 O.OOE+00 Tc-99M 1.78E-03 3.48E-03 5.77E-02 O.OOE+00 5.07E-02 9.51 E+02 4.81 E+03 O.OOE+00 Tc-101 8.10E-05 8.51 E-05 1.08E-03 O.OOE+OO 1.45E-03 5.85E+02 1.63E+01 O.OOE+00 Ru-103 2.79E+03 O.OOE+00 1.07E+03 O.OOE+00 7.03E+03 6.62E+05 4.48E+04 O.OOE+00 Ru-1 05 1.53E+O0 O.OOE+O0 5.55E-01 O.OOE+00 1.34E+00 1.59E+04 9.95E+04 O.OOE+00 Ru-1 06 1.36E+05 O.OOE+00 1.69E+04 O.OOE+00 1.84E+05 1.43E+07 4.29E+05 O.OOE+00 Ag-11 OM 1.69E+04 1.14E+04 9.14E+03 O.OOE+00 2.12E+04 5.48E+06 1.OOE+05 O.OOE+00 Te-125M 6.73E+03 2.33E+03 9.14E+02 1.92E+03 O.OOE+00 4.77E+05 3.38E+04 O.OOE+00 Te-127M 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 O.OOE+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table 5.5-18 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Child PATHWAY = INHALATION AGE GROUP = CHILD NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 2.77E+00 9.51 E-01 6.11E-01 1.96E+00 7.07E+00 1.OOE+04 5.62E+04 O.OOE+00 Te-129M 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 O.OOE+00 Te-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 O.OOE+00 Te-131M 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.OOE+02 2.06E+05 3.08E+05 O.OOE+00 Te-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 O.OOE+00 Te-132 4.81 E+02 2.72E+02 2.63E+02 3.17E+02 1.77E+03 3.77E+05 1.38E+05 O.OOE+00 1-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 O.OOE+00 5.11E+03 O.OOE+00 1-131 4.81 E+04 4.81 E+04 2.73E+04 1.62E+07 7.88E+04 O.OOE+00 2.84E+03 0.00E+00 1-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 O.OOE+00 3.20E+03 O.OOE+00 1-133 1.66E+04 2.03E+04 7.70E+02 3.85E+06 3.38E+04 O.OOE+00 5.48E+03 O.OOE+00 1-134 1.17E+03 2.03E+03 9.95E+02 5.07E+04 3.30E+03 O.OOE+00 9.55E+02 O.OOE+0O 1-135 4.18E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 O.OOE+00 4.44E+03 O.OOE+00 Cs-I 34 6.51 E+05 1.01 E+06 2.25E+05 0.00E+00 3.30E+05 1.21 E+05 3.85E+03 O.OOE+00 Cs-1 36 6.51 E+04 1.71 E+05 1.16E+05 0.00E+00 9.55E+04 1.45E+04 4.18E+03 O.OOE+00 Cs-1 37 9.07E+05 8.25E+05 1.28E+05 0.OOE+00 2.82E+05 1.04E+05 3.62E+03 O.OOE+00 Cs-I 38 6.33E+02 8.40E+02 5.55E+02 0.OOE+00 6.22E+02 6.81 E+01 2.70E+02 O.OOE+00 Ba-1 39 1.84E+00 9.84E-04 5.37E-02 0.OOE+00 8.62E-04 5.77E+03 5.77E+04 O.OOE+00 Ba-140 7.40E+04 6.48E+01 4.33E+03 0.OOE+00 2.11E+01 1.74E+06 1.02E+05 O.OOE+00 Ba-141 1.96E-01 1.09E-04 6.36E-03 0.OOE+00 9.47E-05 2.92E+03 2.75E+02 O.OOE+00 Ba-142 5.OOE-02 3.60E-05 2.79E-03 0.OOE+00 2.91 E-05 1.64E+03 2.74E+00 O.OOE+00 La-1 40 6.44E+02 2.25E+02 7.55E+01 0.OOE+00 O.OOE+00 1.83E+05 2.26E+05 O.OOE+0O La-1 42 1.30E+00 4.11E-01 1.29E-01 0.OOE+00 O.OOE+00 8.70E+03 7.59E+04 O.OOE+00 Ce-141 3.92E+04 1.95E+04 2.90E+03 0.OOE+00 8.55E+03 5.44E+05 5.66E+04 O.OOE+00 Ce-143 3.66E+02 1.99E+02 2.87E+01 0.OOE+00 8.36E+01 1.15E+05 1.27E+05 O.OOE+O0 Ce-144 6.77E+06 2.12E+06 3.61 E+05 0.OOE+00 1.17E+06 1.20E+07 3.89E+05 O.OOE+O0 Pr-143 1.85E+04 5.55E+03 9.14E+02 0.OOE+00 3.OOE+03 4.33E+05 9.73E+04 O.OOE+00 Pr-144 5.96E-02 1.85E-02 3.OOE-03 0.OOE+00 9.77E-03 1.57E+03 1.97E+02 O.OOE+00 Nd-147 1.08E+04 8.73E+03 6.81 E+02 0.OOE+00 4.81 E+03 3.28E+05 8.21 E+04 O.OOE+O0 W-187 1.63E+01 9.66E+00 4.33E+00 0.OOE+00 O.OOE+00 4.11E+04 9.1OE+04 O.OOE+00 Np-239 4.66E+02 3.34E+01 2.35E+01 0.OOE+00 9.73E+01 5.81 E+04 6.40E+04 O.OOE+00 R VALUES IN UNITS OF MREM/YR PER IICI/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREM/YR PER CI/SEC FOR ALL OTHERS.
!1,
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 q ! N iw MAN UAL (O D C M ) REV: 17 Page 143 of 221 Table 5.5-19 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Infant PATHWAY = INHALATION AGE GROUP = INFANT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN H-3 O.OOE+00 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 C-14 2.65E+04 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 O.OOE+00 Na-24 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 O.OOE+00 P-32 2.03E+06 1.12E+05 7.74E+04 O.OOE+00 O.OOE+00 O.OOE+00 1.61 E+04 O.OOE+00 Cr-51 O.OOE+00 O.OOE+00 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 O.OOE+00 Mn-54 O.OOE+00 2.53E+04 4.98E+03 O.OOE+00 4.98E+03 1.OOE+06 7.06E+03 O.OOE+00 MN-56 O.OOE+00 1.54E+00 2.21 E-01 O.OOE+00 1.10E+00 1.25E+04 7.17E+04 O.OOE+00 Fe-55 1.97E+04 1.17E+04 3.33E+03 O.OOE+00 O.OOE+00 8.69E+04 1.09E+03 O.OOE+00 Fe-59 1.36E+04 2.35E+04 9.48E+03 O.OOE+00 O.OOE+00 1.02E+06 2.48E+04 O.OOE+00 Co-58 O.OOE+00 1.22E+03 1.82E+03 O.OOE+00 O.OOE+00 7.77E+05 1.11 E+04 O.OOE+00 Co-60 O.OOE+00 8.02E+03 1.1 8E+04 O.OOE+00 O.OOE+00 4.51 E+06 3.19E+04 O.OOE+00 iK J Ni-63 3.39E+05 2.04E+04 1.16E+04 O.OOE+00 O.OOE+00 2.09E+05 2.42E+03 O.OOE+00 Ni-65 2.39E+00 2.84E-01 1.23E-01 O.OOE+00 O.OOE+00 8.12E+03 5.01 E+04 O.OOE+00 Cu-64 O.OOE+00 1.88E+00 7.74E-01 O.OOE+00 3.98E+00 9.30E+03 1.50E+04 O.OOE+00 Zn-65 1.93E+04 6.26E+04 3.11 E+04 O.OOE+00 3.25E+04 6.47E+05 5.14E+04 O.OOE+00 Zn-69 5.39E-02 9.67E-02 7.18E-03 O.OOE+00 4.02E-02 1.47E+03 1.32E+04 O.OOE+00 Br-83 O.OOE+00 O.OOE+00 3.81 E+02 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 Br-84 O.OOE+00 O.OOE+00 4.00E+02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Br-85 O.OOE+00 O.OOE+00 2.04E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Rb-86 O.OOE+00 1.90E+05 8.82E+04 O.OOE+00 O.OOE+00 O.OOE+00 3.04E+03 O.OOE+00 Rb-88 O.OOE+00 5.57E+02 2.87E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.39E+02 O.OOE+00 Rb-89 O.OOE+00 3.21 E+02 2.06E+02 O.OOE+00 O.OOE+00 O.OOE+00 6.82E+01 O.OOE+00 Sr-89 3.98E+05 O.OOE+00 1.14E+04 O.OOE+00 O.OOE+00 2.03E+06 6.40E+04 O.OOE+00 Sr-90 4.09E+07 O.OOE+00 2.59E+06 O.OOE+00 O.OOE+00 1.12E+07 1.31 E+05 O.OOE+00 Sr-91 9.56E+01 O.OOE+00 3.46E+00 O.OOE+00 O.OOE+00 5.26E+04 7.34E+04 O.OOE+00 Sr-92 1.05E+01 b.OOE+00 3.91 E-01 O.OOE+00 0.00E+00 2.38E+04 1.40E+05 O.OOE+00 Y-90 3.29E+03 O.00E+OO 8.82E+01 O.OOE+00 O.OOE+00 2.69E+05 1.04E+05 O.OOE+00 Y-91 M 4.07E+19 O.OOE+00 1.39E-02 O.OOE+00 O.OOE+00 2.79E+03 2.35E+03 O.OOE+00 Y-91 5.88E+05 O.OOE+00 1.57E+04 O.OOE+O0 O.OOE+00 2.45E+06 7.03E+04 O.OOE+00 Y-92 1.64E+01 O.OOE+00 4.61 E-01 O.OOE+00 O.OOE+00 2.45E+04 1.27E+05 O.OOE+00 Y-93 1.50E+02 O.OO0+0O 4.07E+00 O.OOE+00 O.OOE+00 7.64E+04 1.67E+05 O.OOE+00 Zr-95 1.15E+05 2.79E+04 2.03E+04 O.OOE+00 3.11E+04 1.75E+06 2.17E+04 O.OOE+00 Zr-97 1.50E+02 2.56E+01 1.17E+01 O.OOE+00 2.59E+01 1.10E+05 1.40E+05 O.OOE+00 Nb-95 1.57E+04 6.43E+03 3.78E+03 O.OOE+00 4.72E+03 4.79E+05 1.27E+04 O.OOE+00 Mo-99 O.OOE+00 1.65E+02 3.23E+01 O.OOE+00 2.65E+02 1.35E+05 4.87E+04 O.OOE+00 Tc-99M 1.40E-03 2.88E-03 3.72E-02 O.OOE+00 3.11E-02 8.11 E+02 2.03E+03 O.OOE+00 Tc-101 6.51 E-05 8.23E-05 8.12E-04 O.OOE+00 9.79E-04 5.84E+02 8.44E+02 O.OOE+00 Ru-1 03 2.02E+03 O.OOE+00 6.79E+02 O.OOE+00 4.24E+03 5.52E+05 1.61 E+04 O.OOE+00 KXi Ru-105 1.22E+00 O.OOE+00 4.10 E-01 O.OOE+00 8.99E-01 1.57E+04 4.84E+04 O.OOE+00 Ru-1 06 8.68E+04 O.OOE+00 1.09E+04 O.OOE+00 1.07E+05 1.16E+07 1.64E+05 O.OOE+00 Ag-110M 9.98E+03 7.22E+03 5.00E+03 O.OOE+00 1.09E+04 3.67E+06 3.30E+04 O.OOE+00 Te-125M 4.76E+03 1.99E+03 6.58E+02 1.62E+03 O.OOE+00 4.47E+05 1.29E+04 O.OOE+00 Te-127M 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31 E+06 2.73E+04 O.OOE+00
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION
" W 1: (ODCM)
MANUAL REV:
H4 17 11 F Page 144 of 221 Table 5.5-19 R Values for the Prairie Island Nuclear Generating Plant*
- Inhalation, Infant PATHWAY = INHALATION AGE GROUP = INFANT NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI SKIN Te-127 2.23E+00 9.53E-01 4.76E-01 1.85E+00 4.86E+00 1.03E+04 2.44E+04 O.OOE+00 Te-129M 1.41 E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 O.OOE+00 Te-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.OOE+03 2.63E+04 O.OOE+00 Te-131 M 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+03 1.19E+05 O.OOE+00 Te-131 1.74E-02 8.22E-03 5.OOE-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 O.OOE+00 Te-132 3.72E+02 2.37E+02 1.76E+02 2.79E+02 1.03E+03 3.40E+05 4.41 E+04 O.OOE+00 1-130 6.36E+03 1.39E+03 5.57E+03 1.60E+06 1.53E+04 O.OOE+O0 1.99E+03 O.OOE+00 1-131 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 O.OOE+00 1.06E+03 O.OOE+00 1-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 O.OOE+00 1.90E+03 O.OOE+00 1-133 1.32E+04 1.92E+03 5.60E+03 3.56E+06 2.24E+04 O.OOE+00 2.16E+03 O.OOE+00 1-134 9.21 E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 O.OOE+00 1.29E+03 O.OOE+00 1-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 O.OOE+00 1.83E+03 O.OOE+00 Cs-I 34 3.96E+05 7.03E+05 7.45E+04 O.OOE+00 1.90E+03 7.97E+04 1.33E+03 O.OOE+00 Cs-1 36 4.83E+04 1.35E+05 5.29E+04 O.OOE+00 5.64E+04 1.18E+04 1.43E+03 O.OOE+00 Cs-1 37 5.49E+05 6.12E+05 4.55E+04 O.OOE+00 1.72E+05 7.13E+04 1.33E+03 O.OOE+00 Cs-i 38 5.05E+02 7.81 E+02 3.98E+02 O.OOE+00 4.1OE+02 6.54E+01 8.76E+02 O.OOE+00 Ba-1 39 1.48E+00 9.84E-04 4.30E-02 O.OOE+00 5.92E-04 5.95E+03 5.1 OE+03 O.OOE+00 Ba-140 5.60E+04 5.60E+01 2.90E+03 O.OOE+00 1.34E+01 1.60E+06 3.84E+04 O.OOE+00 Ba-141 1.57E-01 1.08E-04 4.97E-03 O.OOE+00 6.50E-05 2.97E+03 4.75E+03 O.OOE+00 Ba-142 3.98E-02 3.30E-05 1.96E-03 O.OOE+00 1.90E-05 1.55E+03 6.93E+02 O.OOE+00 La-140 5.05E+02 2.OOE+02 5.15E+01 O.OOE+00 O.OOE+00 1.68E+05 8.48E+04 O.OOE+00 La-142 1.03E+00 3.77E-01 9.04E-02 O.OOE+00 O.OOE+00 8.22E+03 5.95E+04 O.OOE+00 Ce-141 2.77E+04 1.67E+04 1.99E+03 O.OOE+00 5.25E+03 5.17E+05 2.16E+04 O.OOE+00 Ce-143 2.93E+02 1.93E+02 2.21 E+01 O.OOE+00 5.64E+01 1.16E+05 4.97E+04 O.OOE+00 Ce-144 3.19E+06 1.21 E+06 1.76E+05 O.OOE+00 5.38E+05 9.84E+06 1.48E+05 O.OOE+00 Pr-1 43 1.40E+04 5.24E+03 6.99E+02 O.OOE+00 1.97E+03 4.33E+05 3.72E+04 O.OOE+00 Pr-144 4.79E-02 1.85E-02 2.41 E-03 O.OOE+00 6.72E-03 1.61 E+03 4.28E+03 O.OOE+00 Nd-147 7.94E+03 8.13E+03 5.OOE+02 O.OOE+00 3.15E+03 3.22E+05 3.12E+04 O.OOE+00 W-187 1.30E+01 9.02E+00 3.12E+00 O.OOE+00 O.OOE+00 3.96E+04 3.56E+04 O.OOE+00 Np-239 3.71 E+02 3.32E+01 1.88E+01 O.OOE+00 6.62E+01 5.95E+04 2.49E+04 O.OOE+00
- R VALUES IN UNITS OF MREM/YR PER [tCl/M 3 FOR INHALATION AND TRITIUM, AND IN UNITS OF M2 -MREMIYR PER pCI/SEC FOR ALL OTHERS.
PRAIRIE ISLALu NUCLEAR GENERATING PLANT
( H PRCEDURE NUMBER:
t$$XSup.iWx I ~~~~~~~~~~~~
z6:X jfitUS<mS OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 145 of 221 Table 7.1 Radiological Environmental Monitoring Program Sample Collection and Analysis
- annples,'V',g'; y ,,i,-',SampHngiandkiggg
- 1. AIRBORNE dsure',,P zithWayt,,',
e, NU Samples from 5 locations:
oca ions, t 1 Qni Frequen Continuous Sampler operation c 11,y WA y,-g uenc Radioiodine analysis weekly for
'V, Radioiodine and 3 samples from offsite locations (in with 'sample collection weekly 1-131 '
Particulates different sectors) of the highest calculated annual average ground level DIQ, Particulate:
1 sample from the vicinity of a community Gross beta activity on each filter having the highest calculated 'annual weekly*. Analysis SHALL be average ground-level D/Q, and 1 sample performed more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> from a control location specified in the following filter change. Perform REMP gamma isotopic analysis on I composite (by location) sample quarterly.
- 2. DIRECT RADIATION 32 TLD stations established with duplicate Quarterly Gamma dose dosimeters placed at the following quarterly locations:
- 1. Using the 16 meteorological wind sectors as guidelines, an inner ring of stations in the general area of the site boundary is established and an outer ring of stations in the 4 to 5 mile distance from the plant site is established. Because of inaccessibility, seven sectors in the inner and outer rings are not covered
- If Gross beta activity in any indictor sample exceeds 10 times the yearly average of the control sample, a gamma isotopic analysis is required.
- Sample locations are further described by the REMP.
NUMBER:
OFFSITE DOSE CALCULATION MANUAL (ODCM)
Table 7.1 Radiological Environmental Monitoring Program Sample Collection and Analysis Ex;poueawy j~>/ubrfSmlsamping ,d, 4<,Tye n Feuec andlor l0~ ampele.lo~
~ ~~~~~~~~'a ' adSamplLocaidn"*-6lct5nFrq e,n°E ,le'dionwa', 6y6WL ~fnayi I'=S1
- 2. DIRECT RADIATION
[Cont'd]
- 2. Seven dosimeters are established at special interest areas and a control station.
- 3. WATERBORNE
- a. Surface Upstream & downstream locations Monthly Composite of weekly Gamma isotopic analysis of each samples (water & ice conditions monthly composite permitting)
Tritium analysis of quarterly composites of monthly composites
- b. Ground 3 samples from wells within 5 miles of the Quarterly Gamma isotopic and tritium plant site and 1 sample from a well greater analyses of each sample than 10 miles from the plant site
- c. Drinking 1 sample from the City of Red Wing water Monthly Composite of weekly 1-131 Analysis and Gross beta supply samples and gamma isotopic analyses of each monthly composite Tritium analysis of quarterly composites of monthly composites
- Sample locations are further described by the REMP.
C PRAIRIE ISLANu NUCLEAR GENERATING PLANT ( C H PROvEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
_______________- . Page 147 of 221 Table 7.1 Radiological Environmental Monitoring Program Sample Collection and Analysis Exposur-Pethway $2j'l M merfSam pl f Sapffionlin aii 3 Yp6AnAe andlor Sa,iiple~~~~~~~~,.
~~~ 7j'nd)S~~~~~rii~~I6 Locatio~~~~~~s**~~~ ~~>j~~C6llecti6h Fi~~~~~~~g&en~~~y I ~~~ ~~of Analtyesisn'
- 3. WATERBORNE
[Cont'd]
- d. Sediment from One sample upstream of plant, one Semiannually Gamma isotopic analysis of each shoreline sample downstream of plant, and one sample from shoreline of recreational area.
- 4. INGESTION
- a. Milk One sample from dairy farm having Semimonthly when animals are Gamma isotopic and 1-131 *1 highest D/Q, one sample from each of on pasture; monthly at other analysis of each sample three dairy farms calculated to have doses times.
from 1-131 >
1 mRem/yr, and one sample from 10-20 miles
- b. Fish and One sample of one game specie of fish Semiannually Gamma isotopic analyses on Invertebrates located upstream and downstream of the each sample (edible portion only plant site on fish) -
One sample of Invertebrates upstream and downstream of the plant site
- Sample locations are further described by the REMP.
NUMBER:
OFFSITE DOSE CALCULATION H4
'0 ~~~~~~ REV: 17 i v~~~~~~~~~
- ., .t ,0-iji/
MANUAL (ODCM)
Page 148 of 221 Table 7.1 Radiological Environmental Monitoring Program Sample Collection and Analysis
'E-xpos-""'e-"P"h""~~ A 'Nurie oSmls 4 Sapkg ypeanc Freqec
,, n!"dPbl" r-Sampl dfidaamPleL,`cations a o IIlection F,ieuency$
- 4. INGESTION
[Cont'd]
- c. Food Products One sample of corn from any field that is At time of harvest Gamma isotopic analysis of irrigated by water into which liquid plant edible portion of each sample wastes have been discharged***
One sample of broad leaf vegetation from At time of harvest 1-131 analyses of edible portion highest D/Q garden and one sample from of each sample 10-20 miles
- Sample locations are further described by the REMP.
- As determined by methods outlined in the ODCM.
C PRAIRIE ISLAi,., NUCLEAR GENERATING PLANT (7 C H PRLt;EDURE Table 7.2 - Reporting Levels for Radioactivity Concentration in Environmental Samples WATER AIRBORNE FISH MILK FOOD ANALYSIS (pCiI) PARTICULATE OR (pCi/kg, wet) (pCi/I) PRODUCTS GASES (pCi/i 3) (pCi/kg, wet)
H-3 20,000(a)
Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400(b) 1-131 2(a) 0.9 3 100 Cs-134 30 10 1,000 60 1,000 Cs-1 37 50 20 2,000 70 2,000 Ba-La-140 200 (b) 300 (b)
(a) Drinking water pathway level.-
(b) Total for parent and daughter.
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
THIS PAGE IS LEFT INTENTIONALLY BLANK
C PRAIRIE ISLANu. NUCLEAR GENERATING PLANT
( C H PROt.EDURE NUMBER:
Hsxri4ti! sK; j§X - OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 151 of 221 Table 7.3 - Detection Capabilities for Environmental Sample Analysis Lower Limit of Detection (LLD)(a)
ANALYSIS WATER AIRBORN FISH MILK FOOD SEDIMENT (pCUI) PARTICULATE (pCi/kg, wet) (pil) PRODUCTS (pCi/kg, dry)
OR GASES- (pCi/kg, wet)
(Pcl/M3)
Gross Beta 4 -0.01 I H-3t 2400(b)
Mn-54 15 130 Fe-9 30 260 Co-58, 6 15 130 Zm-65 30 260 Zr-Nb-95 15 (c).
1-131 (d) 1 (b) 0.07 1 60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-La-1 40 15(C) 15(0)
NUMBER:
OFFSITE DOSE CALCULATION H4 Mj~ XMANUAL (ODCM) REV: 17 Page 152 of 221 Table 7.3 - Table Notation a - The LLD is the smallest concentration of radioactive material in a sample that will be detected with 95% probability with 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system (which may include radiochemical separation):
LLD = 4.66Sb E.V.2.22.Y.exp(-A AT)
Where:
LLD is the apriori lower limit of detection as defined above (as picocurie per unit mass or volume), b is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute). In calculating the LLD for a radionuclide determined by gamma-ray spectrometry, the background SHALL include the typical contributing of other radionuclides normally present in the samples (e.g., potassium-40 in milk samples). Typical values of E, V, Y and At SHALL be used in the calculations.
E is the counting efficiency (as counts per transformation),
2.22 is the number of transformation per minute per picocurie, Y is the fractional radiochemical yield (when applicable),
X is the radioactive decay constant for the particular radionuclide, and AT is the elapsed time between sample collection (or end of the sample collection period) and time of counting.
b - Drinking water pathway limit.
c - Total for parent and daughter d - These LLDs apply only where 13il analysis" is specified.
e - Where "Gamma Isotopic Analysis" is specified, the LLD specification applies to the following radionuclides:
54Mn, 59 Fe, 5 8Co, 600o, 65Zn, Zr-Nb, I 7Cs, 134Cs, and 140Ba-La. Other peaks which are measurable and identifiable, together with the above nuclides, SHALL also be identified and reported.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MAN UAL (O D CM )
11 REV: 17 Page 153 of 221 Figure 3.1 - Prairie Island Nuclear Generating Plant Site Boundary For Liquid Effluents 0
s WISCONSON / ~l~ o~~~~~~~~~~~~,"
Un~~~~~~n rZ Z W l S °}D_X" I I I
If V
Z,
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
_____ Page 154 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 155 of 221 Figure 3.2 - Prairie Island Nuclear Generating Plant Site Boundary For Gaseous Effluents
%=J sc oCO h I 0_iA w ~~~~0
~~ 0 ~~~w
-j
-0
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE GENERATING NUCLEAR PLANT PRAIRIEISLAD H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (DCM) REV: 17 Page 156 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) XREV: 17
_ _I__ Page 157 of 221 Appendix A Meteorological Analyses Table A-1 Release Conditions Table A-2 Distance to Site Boundary Table A-3 Long Term - Ground Level - Site Boundary - X/Q and D/Q Table A-4 Long Term - Ground Level - Standard Distances -
%IQ Table A-5 Long Term - Ground Level - Standard Distances -
- D/Q Table A-6 Short Term - Ground Level - Site Boundary - X/q and D/q Table A-7 Short Term - Ground Level - Standard Distances - X/q Table A-8 Short Term - Ground Level - Standard Distances - D/q
.PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 F___Page 158 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT HNPROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 159 of 221 Appendix A Summary of Dispersion Calculational Procedures Undepleted, undecayed dispersion parameters were computed using the computer program XOQDOQ (Sagendorf and Goll, 1977). Specifically, sector average X/Q and D/Q values were obtained for a sector width of 22.5 degrees. Building wake corrections were used to adjust calculations for ground-level releases. Standard open terrain recirculation correction factors were also applied as available as default values in XOQDOQ.
Dispersion calculations were based on ground level releases for the shield buildings, turbine buildings, and auxiliary building (hereafter referred to as the plant complex). A summary of release conditions used as input to XOQDOQ is presented in Table A-1 and controlling site boundary distances are defined in Table A-2. Computed X/Q and D/Q values for site boundary locations (relative to release points) and for standard distances (to five miles from the source in 0.1 mile increments) are presented in Tables A-3 through A-8.
Onsite meteorological data for the period April 1, 1977 through March 31, 1978 (as presented in Appendix B) were used as input to XOQDOQ. Data were collected and AT stability classes were defined in conformance with NRC Regulatory Guide 1.23. Dspersion calculations for the plant complex were based on AT 42.7-1 2.2m and 12.2 meter wind data aoint data recovery of 96 percent).
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 160 of 221 REFERENCES
- 1. Sagendorf, J.F. and Goll, J.T., XOQDOQ Program for the Evaluation of Routine Effluent Releases at Nuclear Power Stations, NUREG-0324, U.S. Nuclear Regulatory Commission, September 1977.
C PRAIRIE ISLANU NUCLEAR GENERATING PLANT
( H PRQtdDURE p*g::,6E.~ ,'; NUMBER: , ........ b';9.,2,I'.,,
.7
- OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 161 of 221 Table A Prairie Island Release Conditions Shield Buildings Auxiliary Building Turbine Building Type Release Ground Level Ground Level Ground Level (Long Term and Short Term) (Long Term) (Long Term)
Release Point Height (m) 56.4 24.4 33.6, 12.2 Adjacent Building Height 62.2 62.2* 62.2*
Relative Location to Adjacent Structures Adjacent to Adjacent to Adjacent to Auxiliary Building Auxiliary Building Auxiliary Building Exit Velocity (m/sec) N.A. N.A. N.A.
Internal Stack Diameter (m) N.A. N.A. N.A.
Building Cross-Sectional Area (M2) 2,170 2,170** 2,170**
Purge Frequency *** (times/yr) 20 N.A. N.A.
Purge Duration*** (hours/release) 5 N.A. N.A.
- Height of Shield Buildings
- Shield Building cross-sectional area
- Applied to short-term calculations only
NUMBER:
U.
U-. OFFSITE DOSE CALCULATION H4 I...' MANUAL (ODCM) REV: 17 Page 162 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
H4 OFFSITE DOSE CALCULATION REV: 17 iw l ~MANUAL (ODCM)
Page 163 of 221 Table A-2 Distances (Miles) to Controlling Site Boundary Locations As Measured from Edge of Plant Complex Sector Distance N 0.28 NNE 0.26 NE 0.84*
ENE 0.62*
E 0.59*
ESE 0.61*
SE 0.67 SSE 0.43 S 0.43 SSW 0.40 SW 0.40 WSW 0.37 W 0.36 WNW 0.36 NW 0.43 NNW 0.48
- Over-water distances
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE.
NUMBER:
H4 OFFSITE DOSE CALCULATION REV: 17 MANUAL (ODCM)
____ Page 164 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLANu NUCLEAR GENERATING PLANT ( C H PRU%..EDURE NUMBER:
OFFSITE DOSE CALCULATION R 1
.MANUAL(ODCM) Page 17 REV:165 of 221 Table A-3 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters for Long Term Ground Level Releases
> 500 Hrs/Yr or > 150 Hrs/QTR for Site Boundary Locations (identified in Table A-2)
Site vIQ (sec/m 3 ) DIQ (u/M2 )
Boundary Sector N 1.82E-05 1.18E-07 NNE 1.52E-05 8.55E-08 NE 1.83E-06 7.74E-09 ENE 3.25E-06 1.84E-08 E 1.05E-05 4.23E-08 ESE 1.86E-05 7.30E-08 SE 1.67E-05 6.80E-08 SSE 1.95E-05 6.81 E-08 S 8.12E-06 3.19E-08 SSW 7.08E-06 2.55E-08 SW 7.66E-06 2.77E-08 WSW 1.13E-05 3.53E-08 w 2.66E-05 7.63E-08 WNW 3.38E-05 1.42E-07 NW 2.13E-05 9.02E-08 NNW 1.11E-05 5.43E-08 Period of Record: 4/1/77 - 3/31/78
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLANu NUCLEAR GENERATING PLANT
( H PROEDURE Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/Q), SEC/M 3 , for Long Term Ground Level Releases
> 500 HrsNr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector - 0.1 0.2 0.3 0.4 0.5 ' 0.6 0.7 N 1.20E-04 3.44E-05 1.66E-05 1.02E-05 7.04E-06 5.29E-06 4.13E-06 NNE 8.53E-05 2.44E-05 1.18E-05 7.20E-06 4.93E-06 3.67E-06 2.83E-06 NE 8.18E-05 2.35E-05 1.14E-05 6.87E-06 4.69E-06 3.49E-06 2.69E-06 ENE 7.88E-05 2.26E-05 1.1 OE-05 6.70E-06 4.62E-06 3.46E-06 2.69E-06 E - 2.40E-04' 6.89E-05 3.34E-05 2.02E-05 1.38E-05 1.02E-05 7.88E-06 ESE 4.52E-04' 1.30E-04 6.28E-05 3.80E-05 2.59E-05 1.92E-05 1.48E-05 SE 4.85E-04 1.39E-04 6.74E-05 4.07E-05 2.77E-05 2.04E-05 1.56E-05 SSE 2.59E-04 7.44E-05 3.60E-05 2.17E-05 1.48E-05 1.10E-05 8.44E-06
'S 1.08E-04 3.09E-05 1.46E-05 9.06E-06 6.20E-06 4.62E-06 3.58E-06 SSW 8.60E-05 2.46E-05 1.19E-05 7.19E-06 4.91 E-06 3.66E-06 2.83E-06 SW 9.19E-05 2.62E-05 1.26E-05 7.72E-06 5.31 E-06 3.98E-06 3.09E-06 WSW 1.17E-04 3.35E-05 1.61 E-05 9.80E-06 6.70E-06 4.97E-06 3.83E-06 W 2.64E-04 7.56E-05 3.66E-05 2.22E-05 1.51 E-05 1.12E-05 8.61 E-06 WNW 3.42E-04 9.80E-05 4.75E-05 2.88E-05 1.98E-05 1.47E-05 1.14E-05 NW 2.91 E-04 8.35E-05 4.05E-05 ,2.46E-05 1.68E-05 1.25E-05 9.67E-06 NNW 1.76E-04 5.04E-05 2.45E-05 1.50E-05 1.03E-05 7.70E-06 5.99E-06 Period of Record: 4/1/77 - 3/31/78
NUMBER:
H01111- -1 OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 168 of 221 Aj. . _
Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/Q), SEC/M 3 , for Long Term Ground Level Releases
> 500 Hrs/Yr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 0.8 0.9 1.0 1.1 1.2 1.3 1.4 N 3.18E-06 2.39E-06 1.87E-06 1.51 E-06 1.24E-06 1.04E-06 8.80E-07 NNE 2.17E-06 1.62E-06 1.27E-06 1.02E-06 8.33E-07 6.95E-07 5.90E-07 NE 2.06E-06 1.54E-06 1.20E-06 9.60E-07 7.86E-07 6.56E-07 5.56E-07 ENE 2.07E-06 1.55E-06 1.21 E-06 9.72E-07 7.98E-07 6.66E-07 5.65E-07 E 6.02E-06 4.51 E-06 3.52E-06 2.82E-06 2.31 E-06 1.93E-06 1.64E-06 ESE 1.13E-05 8.44E-06 6.58E-06 5.28E-06 4.33E-06 3.62E-06 3.07E-06 SE 1.19E-05 8.92E-06 6.96E-06 5.58E-06 4.58E-06 3.82E-06 3.25E-06 SSE 6.45E-06 4.82E-06 3.76E-06 3.01 E-06 2.47E-06 2.06E-06 1.75E-06 S 2.74E-06 2.06E-06 1.61 E-06 1.29E-06 1.06E-06 8.88E-07 7.54E-07 SSW 2.17E-06 1.63E-06 1.27E-06 1.02E-06 8.36E-07 6.99E-07 5.93E-07 SW 2.38E-06 1.78E-06 1.39E-06 1.12E-06 9.17E-07 7.66E-07 6.50E-07 WSW 2.93E-06 2.19E-06 1.71 E-06 1.37E-06 1.12E-06 9.35E-07 7.93E-07 W 6.57E-06 4.91 E-06 3.83E-06 3.07E-06 2.51 E-06 2.1OE-06 1.78E-06 WNW 8.77E-06 6.58E-06 5.14E-06 4.13E-06 3.39E-06 2.83E-06 2.41 E-06 NW 7.40E-06 5.56E-06 4.35E-06 3.50E-06 2.88E-06 2.41 E-06 2.05E-06 NNW 4.60E-06 3.46E-06 2.71 E-06 2.18E-06 1.79E-06 1.50E-06 1.28E-06 Period of Record: 4/1/77 - 3/31/78
C PRAIRIE ISLANu, NUCLEAR GENERATING PLANT (3 H PRtiJDURE NUMBER:
OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 169 of 221 Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/Q), SEC/M 3 , for Long Term Ground Level Releases
> 500 HrsYr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 1.5 1.6 1.7 1.8 1.9 2.0 2.1
-N 7.57E-07 6.59E-07 5.79E-07 5.13E-07 4.59E-07 4.14E-07 3.76E-07 NNE 5.07E-07 4.41 E-07 3.87E-07 3.43E-07 3.07E-07 2.77E-07 2.52E-07 NE 4.77E-07 4.15E-07 3.64E-07 3.23E-07 2.89E-07 2.61 E-07 2.38E-07 ENE 4.86E-07 4.23E-07 3.71 E-07 3.29E-07 2.94E-07 2.65E-07 2.41 E-07 E 1.41 E-06 1.23E-06 1.08E-06 9.55E-07 8.56E-07 7.75E-07 7.05E-06 ESE 2.64E-06 2.30E-06 2.02E-06 1.79E-06 1.61 E-06 1.46E-06 1.32E-06 SE 2.79E-06 2.43E-06 2.14E-06 1.90E-06 1.70E-06 1.54E-06 1.40E-06 SSE 1.50E-06 1.31 E-06 1.15E-06 1.02E-06 9.12E-07 8.25E-07 7.51 E-07 S 6.49E-07 5.65E-07 4.97E-07 4.41 E-07 3.95E-07 3.56E-07 3.24E-07 SSW 5.1 OE-07 4.44E-07 3.90E-07 3.46E-07 3.1 OE-07 2.801E-07 2.54E-07 SW 5.59E-07 4.87E-07 4.27E-07 3.79E-07 3.39E-07 3.06E-07 2.78E-07 WSW 6.82E-07 5.93E-07 5.21 E-07 4.61 E-07 4.13E-07 3.74E-07 3.40E-07 W 1.53E-06 1.33E-06 1.17E-06 1.04E-06 9.29E-07 8.40E-07 7.64E-07 WNW 2.07E-06 1.80E-06 1.59E-06 1.41 E-06 1.26E-06 I.14E-06 1.03E-06 NW 1.76E-06 1.54E-06 1.35E-06 1.20E-06 1.08E-06 9.72E-06 8.83E-07 NNW 1.1OE-06 9.59E-07 8.43E-07 7.47E-07 6.69E-07 6.04E-07 5.49E-07 Period of Record: 4/1/77 - 3/31/78
$ III-.1.-
NUMBER:
- S.~~~~~
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 170 of 221 Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/Q), SEC/M 3 , for Long Term Ground Level Releases
> 500 HrsNr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 2.2 2.3 2.4 2.5 2.6 2.7 2.8 N 3.42E-07 3.14E-07 2.89E-07 2.67E-07 2.47E-07 2.30E-07 2.15E-07 NNE 2.30E-07 2.11E-07 1.94E-07 1.80E-07 1.67E-07 1.56E-07 1.45E-07 NE 2.17E-07 1.99E-07 1.84E-07 1.70E-07 1.58E-07 1.47E-07 1.38E-07 ENE 2.20E-07 2.01 E-07 1.85E-07 1.71 E-07 1.59E-07 1.48E-07 1.38E-07 E 6.44E-07 5.92E-07 5.46E-07 5.05E-07 4.70E-07 4.38E-07 4.09E-07 ESE 1.21 E-06 1.11E-06 1.03E-06 9.51 E-07 8.84E-07 8.25E-07 7.71 E-07 SE 1.28E-06 1.18E-06 1.09E-06 1.01 E-06 9.37E-07 8.74E-07 8.17E-07 SSE 6.86E-07 6.31 E-07 5.82E-07 5.39E-07 5.01 E-07 4.67E-07 4.37E-07 S 2.96E-07 2.71 E-07 2.50E-07 2.31 E-07 2.15E-07 2.OOE-07 1.87E-07 SSW 2.32E-07 2.13E-07 1.96E-07 1.82E-07 1.69E-07 1.57E-07 1.47E-07 SW 2.53E-07 2.32E-07 2.14E-07 1.98E-07 1.83E-07 1.71 E-07 1.59E-07 WSW 3.11E-07 2.85E-07 2.63E-07 2.43E-07 2.26E-07 2.11E-07 1.97E-07 W 6.99E-07 6.42E-07 5.93E-07 5.49E-07 5.1 OE-07 4.76E-07 4.45E-07 WNW 9.44E-07 8.67E-07 7.99E-07 7.39E-07 6.86E-07 6.39E-07 5.97E-07 NW 8.07E-07 7.41 E-07 6.83E-07 6.32E-07 5.87E-07 5.47E-07 5.12E-07 NNW 5.01 E-07 4.59E-07 4.23E-07 3.91 E-07 3.63E-07 3.38E-07 3.15E-07 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAL UCLEAR GENERATING PLANT
( HPRL..OLRE NUMBER:
OFFSITE DOSE CALCULATION l1 MANUAL (ODCM) REV: 17 Pagel171 of 22 Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (X/Q), SEC/M 3 , for Long Term Ground Level Releases
> 500 HrsYr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 2.9 3.0 3.1 3.2 3.3 3.4 3.5 N 2.01 E 1.88E-07 1.77E-07 1.67E-07 1.58E-07 1.49E-07 1-.42E-07 NNE 1.36E-07 1.28E-07 1.20E-07 1;14E-07 1.07E-07 1.02E-07 9.65E-08 NE 1.29E-07 1.21 E-07 I .14E-07 1.08E-07 1.02E-07 9.69E-08 9.20E-08 ENE 1.29E-07 1.21 E-07 1.14E-07 1,07E-07 1.01 E-07 9.60E-08 9.11 E-08 E 3.84E-07 3.61 E-07 3,40E-07 3.21 E-07 3.04E-07 2.88E-07 2.74E-07 ESE 7.23E-07 6.80E-07 6.41 E-07 6.05E-07 5.73E-07 5.43E-07 5.16E-07 SE 7,67E-07 7.21 E-07 6.80E-07 6.42E-07 6.08E-07 5.77E-07 5.48E-07 SSE 4.1OE-07 3.85E-07 3.63E-07 3.43E-07 3.24E-07 3.08E-07 2.92E-07
. S 1.75E-07 1.64E-07 1.55E-07 1,46E-07 1.38E-07 1.31 E-07 1.24E-07 SSW 1.38E-07 1.29E-07 1.22E-07 1.15E-07 1.09E-07 1.03E-07 9.77E-08 SW 1.49E-07 1.40E-07 1.32E-07 1.24E-07 1.17E-07 1.11 E-07 1.05E-07 WSW 1.85E-07 1.74E-07 1.64E-07 1.54E-07 1.46E-07 1.39E-07 1.32E-07 W 4.17E-07 3.92E-07 3.70E-07 3.49E-07 3.30E-07 3.13E-07 2.98E-07 WNW 5.60E-07 5.26E-07 4.95E-07 4.67E-07 4.42E-07 4.19E-07 3.98E-07 NW 4.79E-07 4.50E-07 4.24E-07 4.OOE-07 3.79E-07 3.59E-07 3.41 E-07 NNW 2.95E-07 2.77E-07 2.61 E-07 2.46E-07 2.32E-07 2.20E-07 2.09E-07
\Period of Record: 4/1/77 - 3/31/78
- A;:L:n~~~~~~~~~~~~~~-k-"1,'.
NUMBER:
Jn.:
- a)7Ww~~~~~~~z . 41--
H4 OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 172 of 221 I_ _ _ _ _ _ _ _
Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (X/Q), SEC/M 3, for Long Term Ground Level Releases
> 500 Hrs/Yr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 3.6 3.7 3.8 3.9 4.0 4.1 4.2 N 1.35E-07 1.28E-07 1.22E-07 1.16E-07 1.1IE-07 1.07E-07 1.02E-07 NNE 9.18E-08 8.74E-08 8.34E-08 7.97E-08 7.62E-08 7.30E-08 7.OOE-08 NE 8.75E-08 8.34E-08 7.96E-08 7.61 E-08 7.28E-08 6.98E-08 6.70E-08 ENE 8.66E-08 8.24E-08 7.86E-08 7.50E-08 7.17E-08 6.86E-08 6.58E-08 E 2.60E-07 2.48E-07 2.37E-07 2.26E-07 2.17E-07 2.08E-07 1.99E-07 ESE 4.91 E-07 4.68E-07 4.47E-07 4.27E-07 4.09E-07 3.92E-07 3.76E-07 SE 5.22E-07 4.97E-07 4.75E-07 4.54E-07 4.35E-07 4.17E-07 4.00E-07 SSE 2.78E-07 2.65E-07 2.53E-07 2.42E-07 2.32E-07 2.22E-07 2.13E-07 S 1.18E-07 1.12E-07 1.07E-07 1.02E-07 9.79E-08 9.38E-08 8.99E-08 SSW 9.29E-08 8.85E-08 8.44E-08 8.07E-08 7.72E-08 7.39E-08 7.09E-08 SW 1.OOE-07 9.54E-08 9.1 OE-08 8.69E-08 8.31 E-08 7.95E-08 7.62E-08 WSW 1.25E-07 1.19E-07 1.14E-07 1.09E-07 1.04E-07 9.98E-08 9.57E-08 W 2.83E-07 2.70E-07 2.58E-07 2.47E-07 2.36E-07 2.26E-07 2.17E-07 WNW 3.78E-07 3.60E-07 3.44E-07 3.28E-07 3.14E-07 3.01 E-07 2.89E-07 NW 3.24E-07 3.09E-07 2.95E-07 2.82E-07 2.70E-07 2.58E-07 2.48E-07 NNW 1.99E-07 1.89E-07 1.80E-07 1.72E-07 1.65E-07 1.58E-07 1.51 E-07 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAND NUCLEAR GENERATING PLANT C C-H PRO"DURE Table A-4 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/Q), SEC/M 3 , for Long Term Ground Level Releases
> 500 HrsNr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5.0 N 9.79E-08 9.41 E-08 9.04E-08 8.71 E-08 8.39E-08 8.09E-08 7.81 E-08 7.54E-08 NNE 6.72E-08 6.46E-08 6.22E-08 5.99E-08 5.77E-08 5.57E-08 5.38E-08 5.20E-08 NE 6.43E-08 6.18E-08 5.95E-08 5.74E-08 5.53E-08 5.34E-08 5.16E-08 4.99E-08 ENE 6.31 E-08 6.06E-08 5.83E-08 5.62E-08 5.41 E-08 5.22E-08 5.04E-08 4.87E-08 E 1.91 E-07 1.84E-07 1.77E-07 1.71 E-07 1.65E-07 1.59E-07 1.54E-07 1.49E-07 ESE 3.62E-07 3.48E-07 3.35E-07 3.23E-07 3.11E-07 3.01 E-07 .2.91 E-07 2.81 E-07 SE 3.85E-07 3.70E-07 3.56E-07 3.44E-07 3.31 E-07 3.20E-07 3.09E-07 2.99E-07 SSE 2.05E-07 1.97E-07 1.90E-07 1.83E-07 1.76E-07 1.70E-07 1.65E-07 1.59E-07 S 8.63E-08 8.30E-08 7.98E-08 7.69E-08 7.41 E-08 7.15E-08 6.91 E-08 6.68E-08 SSW 6.81 E-08 6.55E-08 6.30E-08 6.07E-08 5.85E-08 5.65E-08 5.46E-08 5.27E-08 SW 7.32E-08 7.03E-08 6.76E-08 6.51 E-08 6.28E-08 6.06E-08 5.85E-08 5.65E-08 WSW 9.19E-08 8.84E-08 8.51 E-08 8.20E-08 7.91 E-08 7.64E-08 7.38E-08 7.14E-08 W 2.09E-07 2.01 E-07 1.93E-07 1.86E-07 1.80E-07 1.73E-07 1.68E-07 1.62E-07 WNW 2.77E-07 2.66E-07 2.56E-07 2.47E-07 2.38E-07 2.30E-07 2.22E-07 2.15E-07 NW 2.38E-07 2.29E-07 2.20E-07 2.12E-07 2.05E-07 1.97E-07 1.91 E-07 1.84E-07 NNW 1.45E-07 1.39E-07 1.34E-07 1.29E-07 1.24E-07 1.20E-07 1I.16E-07 1.12E-07 Period of Record: 4/1/77 - 3/31178
NUMBER:
I . ; m)..t..
., Z.SX >b\..,,
- 4.jj tg' '4s'>'4 ,.ri,j, ili4 OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 174 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
(
PRAIRIE ISLA. NUCLEAR GENERATING PLANT
( H PRCL.tDURE
- NUMBER:
KI j>j4t3Sssti W >OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 175 of 221 Table A-5 Prairie Island Dispersion Parameters
- Prairie Island Dispersion Parameters (D/Q),1/r 2 , for Long Term Ground Level Releases
> 500 Hrs/Yr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector '0.1 0.2 - 0.3 0.4 0.5 0.6 - 0.7.
N 5.38E-07 2.01 E-07 1.09E-07 6.97E-08 4.87E-08 3.62E-08, 2.81 E-08 NNE 3.39E-07 1.27E-07 6.87E-08 4.39E-08 3.07-08 2.28E-08 1.77E-08 NE 2.21 E-07 8.28E-08 4.49E-08 2.87E-08 2.01 E-08 1.49E-08 1.16E-08 ENE 2.88E-07 1.08E-07 5.85E-08 3.73E-08 2.61 E-08 1.94E-08 1.51 E-08 E 6.15E-07.' 2.30E-07 I.25E-07 7.97E-08 5.57E-08 4.14E-08 3.22E-08 ESE 1.12E-06 4.19E-07 2.27E-07 1.45E-07 1.02E-07 7.54E-08' 5.86E-08 SE' 1.22E-06 4.55E-07 2.47E-07 1.58E-07 1.1OE-07 8.19E-08 6.36E-08 SSE 5.81 E-07 2.17E-07 1.18E-07 7.53E-08 5.27E-08 3.91 E-08 3.04E-08 S 2.72E-07 1.02E-07 5.53E-08 3.53E-08 2.47E-08 1.83E-08 1.42E-08 SSW 2.00E-07 7.47E-08 4.06E-08 2.59E-08 1.81 E-08 1.34E-08 1.04E-08 SW 2.16E-07 8.06E-08 4.38E-08 2.79E-08 1.95E-08 1.45E-08 1.13E-08 WSW 2.39E-07 8.93E-08 4.85E-08 3.09E-08 2.16E-08 1.61 E-08 1.25E-08 W 5.00E-07 1.87E-07 1.01 E-07, 6.47E-08 4.53E-08 3.36E-08 2.61 E-08 WNW 9.50E-07 3.55E-07 1.93E-07 1.23E-07 8.60E-08 6.39E-08 4.96E-08 NW 7.95E-07 2.97E-07 1.61 E-07 7.03E-07 7.20E-08 5.35E-08 4.15E-08 NNW 5.54E-07 2.07E-07 1.12E-07 7.17E-08 5.02E-08 3.72E-08 2.89E-08 Period of Record: 4/1/77 - 3/31/78
NUMBER:
H4 OFFSITE DOSE CALCULATION MANUAL (ODCM)
Table A-5 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/Q), 1/M2 , for Long Term Ground Level Releases
> 500 HrsYr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 0.8 0.9 1.0 1.1 1.2 1.3 1.4 N 2.13E-08 1.56E-08 1.19E-08 9.32E-09 7.47E-09 6.1OE-09 5.07E-09 NNE 1.34E-08 9.84E-09 7.49E-09 5.87E-09 4.70E-09 3.84E-09 3.19E-09 NE 8.76E-09 6.43E-09 4.90E-09 3.83E-09 3.07E-09 2.51 E-09 2.09E-09 ENE 1.14E-08 8.37E-09 6.37E-09 4.99E-09 4.OOE-09 3.27E-09 2.72E-09 E 2.43E-08 1.79E-08 1.36E-08 1.07E-08 8.54E-09 6.98E-09 5.80E-09 ESE 4.43E-08 3.26E-08 2.48E-08 1.94E-08 1.56E-08 1.27E-08 1.06E-08 SE 4.81E-08 3.54E-08 2.69E-08 2.11E-08 1.69E-08 1.38E-08 1.15E-08 SSE 2.30E-08 1.69E-08 1.29E-08 1.01 E-08 8.07E-09 6.59E-Q9 5.48E-09
-S 1.08E-08 7.92E-09 6.03E-09 4.72E-09 3.78E-09 3.09E-09 2.57E-09 SSW 7.91 E-09 5.81 E-09 4.42E-09 3.46E-09 2.77E-09 2,27E-09 1.88E-09 SW 8.53E-09 6.26E-09 4.77E-09 3.73E-09 2.99E-09 2.45E-09 2.03E-09 WSW 9.45E-09 6.94E-08 5.28E-09 4.14E-09 3.32E-09 2.71 E-09 2.25E-09 W 1.98E-08 1.45E-08 1.10E-08 8.65E-09 6.93E-09 5.67E-09 4.71E-09 WNW 3.76E-08 2.76E-08 2.1OE-08 1.64E-08 1.32E-08 1.08E-08 8.95E-09 NW 3.14E-08 2.31E-08 1.76E-08 1.38E-08 1.10E-08 9.02E-09 7.49E-09 NNW 2.19E-08 1.61E-08 1.22E-08 9.59E-09 7.68E-09 6.28E-09 5.22E-09 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAC NUCLEAR GENERATING PLANT ( C H PR-,-dDURE NUMBER:
OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 177 of 221 Table A-5 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (DIQ),1/r 2, for Long Term Ground Level Releases
> 500 HrsYr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 1.5 1.6 1.7 1.8 1.9 2.0 2.1 N 4.27E-09 3.65E-09 3.14E-09 2.73E-09 2.40E-09 2.12E-09 1.89E-09 NNE 2.69E-09 2.30E-09 1.98E-09 1.72E-09 1.51 E-09 1.33E-09 1.19E-09 NE 1.76E-09 1.50E-09 1.29E-09 1.13E-09 9.87E-1 0 8.72E-10 7.76E-1 0 ENE 2.29E-09 1.95E-09 1.68E-09 1.46E-09 1.28E-09 1.14E-09 1.01 E-09 E 4.88E-09 4.17E-09 3.59E-09 3.13E-09 2.74E-09 2.42E-09 2.16E-09 ESE 8.90E-09 7.59E-09 6.54E-09 5.69E-09 4.99E-09 4.41 E-09 3.93E-09 SE 9.66E-09 8.25E-09 7.11E-09 6.18E-09 5.43E-09 4.79E-09 4.27E-09 SSE 4.61 E-09 3.94E-09 3.39E-09 2.95E-09 2.59E-09 2.29E-09 2.04E-09 S: 2.16E-09 1.85E-09 1.59E-09 1.38E-09 1.21 E-09 1.07E-09 9.55E-1 0 SSW 1.59E-09 1.35E-09 1.17E-09 1.02E-09 8.91 E-1 0 7.87E-1 0 7.OOE-10 SW 1.71 E-09 1.46E-09 1.26E-09 1.10E-09 9.61 E-10 8.49E-10 7.56E-1 0 WSW 1.90E-09 1.62E-09 1.40E-09 1.21 E-09 1.06E-09 9.41 E-1 0 8.37E-1 0 w 3.97E-09 3.39E-09 2.92E-09 2.54E-09 2.23E-09 1.97E-09 1.75E-09 WNW 7.54E-09 6.44E-09 5.55E-09 4.83E-09 4.23E-09 3.74E-09 3.33E-09 NW 6.31 E-09 5.39E-09 4.64E-09 4.04E-09 3.54E-09 3.13E-09 2.79E-09 NNW 4.40E-09 3.75E-09 3.23E-09 2.81 E-09 2.47E-09 2.18E-09 1.94E-09 Period of Record: 4/1/77 - 3/31/78
<H ,~
~~~~k",, OFFSITE DOSE CALCULATION MANUAL (ODCM)
NUMBER:
REV:
H4 17 Page 178 of 221 Table A-5 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/Q), 1/M2, for Long Term Ground Level Releases
> 500 Hrs/Yr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 2.2 2.3 2.4 2.5 2.6 2.7 2.8 N 1.69E-09 1.52E-09 1.37E-09 1.25E-09 1.14E-09 1.04E-09 9.58E-10 NNE 1.06E-09 9.56E-10 8.65E-1 0 7.86E-1 0 7.17E-10 6.57E-1 0 6.03E-10 NE 6.95E-1 0 6.25E-1 0 5.65E-10 5.13E-10 4.69E-10 4.29E-10 3.94E-1 0 ENE 9.40E-10 8.14E-1 0 7.36E-1 0 6.68E-1 0 6.1 OE-1 0 5.59E-10 5.13E-10 E 1.93E-09 1.74E-09 1.57E-09 1.43E-09 1.30E-09 1.19E-09 1.10E-09 ESE 3.51 E-09 3.16E-09 2.86E-09 2.60E-09 2.37E-09 2.17E-09 2.OOE-09 SE 3.82E-09 3.44E-09 3.11 E-09 2.82E-09 2.58E-09 2.36E-09 2.17E-09 SSE 1.82E-09 1.64E-09 1.48E-09 1.35E-09 1.23E-09 1.13E-09 1.04E-09 S 8.55E-1 0 7.69E-10 6.95E-1 0 6.32E-10 5.77E-1 0 5.28E-10 4.85E-10 SSW 6.27E-1 0 5.64E-10 5.1 OE-1 0 4.63E-1 0 4.23E-1 0 3.87E-1 0 3.56E-10 SW 6.76E-1 0 6.09E-1 0 5.50E-10 5.00E-1 0 4.56E-1 0 4.18E-10 3.84E-1 0 WSW 7.49E-10 6.74E-1 0 6.10E-10 5.54E-1 0 5.06E-1 0 4.63E-1 0 4.26E-1 0 W 1.57E-09 1.41 E-09 1.28E-09 1.16E-09 1.06E-09 9.68E-1 0 8.90E-1 0 WNW 2.98E-09 2.68E-09 2.42E-09 2.20E-09 2.01 E-09 1.84E-09 1.69E-09 NW 2.49E-09 2.24E-09 2.03E-09 1.84E-09 1.68E-09 1.54E-09 1.42E-09 NNW 1.74E-09 1.56E-09 1.41 E-09 1.28E-09 1.17E-09 1.07E-09 9.86E-1 0 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAND NUCLEAR GENERATING PLANT ( H PRCE-OURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 179 of 221 Table A-5 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/Q), I/M2 , for Long Term Ground Level Releases
> 500 HrsYr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector ' 2.9 3.0 3.1 3.2 3.3 3.4 3.5
-N 8.84E-10 8.17E-10 7.58E-10 7.05E-1 0 6.57E-1 0 6.14E-10 5.75E-1 0 NNE 5.56E-1 0 5.15E-10 4.77E-1 0 4.44E-1 0 4.14E-1 0 3.87E-1 0 3.62E-1 0 NE 3.64E-10 3.36E-1 0 3.12E-10 2.90E-1 0 2.70E-10 2.53E-1 0 2.37E-1 0 ENE 4.73E 4.38E-1 0 4.06E-1 0 3.78E-1 0 3.52E-1 0 3.29E-1 0 3.08E-1 0 E 1.01 E-09 9.34E-1 0 8.67E-1 0 8.06E-1 0 7.51 E-1 0 7.02E-1 0 6.57E-10 ESE 1.84E-09 1.70E-09 1.58E-09 1.47E-09 1.37E-09 1.28E-09 1.20E-09 SE 2.OOE-09 1.85E-09 1.71 E-09 1.59E-09 1.49E-09 1.39E-09 1.30E-09 SSE 9.55E-1 0 8.83E-1 0 8.19E-10 7.61 E-1 0 7.10E-10 6.63E-1 0 6.21 E-10 S 4.47E-1 0 4.14E-10 3.84E-1 0 3.57E-10 3.33E-1 0 3.11 E-10 2.91 E-10 SSW 3.28E-1 0 3.04E-10 2.82E-10 2.62E-10 2.44E-10 2.28E-10 2.14E-10 SW 3.54E-10 3.27E-1 0 3.04E-1 0 2.82E-1 0 2.63E-1 0 2.46E-10 2.30E-1 0 WSW 3.92E-10 3.63E-1 0 3.37E-1 0 3.13E-1 0 2.92E-1 0 2.73E-1 0 2.55E-1 0 w 8.20E-10 7.59E-1 0 7.04E-1 0 6.54E-1 0 6.1 OE-1 0 5.70E-1 0 5.34E-1 0 WNW 1.56E-09 I1.44E-09 1.34E-09 1.24E-09 1.16E-09 1.08E-09 1.01E-09 NW 1.31 E-09 1.21 E-09 1.12E-09 1.04E-09 9.71 E-1 0 9.07E-1 0 8.49E-10 NNW 9.09E-1 0 8.41 E-10 7.80E-1 0 7.25E-1 0 6.76E-1 0 6.32E-1 0 5.92E-1 0 Period of Record: 4/1/77 - 3/31/78
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
Table A-5 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/Q), 1/M2 , for Long Term Ground Level Releases
> 500 HrsYr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 3.6 3.7 3.8 3.9 4.0 4.1 4.2 N 5.40E-10 5.07E-1 0 4.78E-10 4.51 E-10 4.26E-10 4.03E-1 0 3.82E-1 0 NNE 3.40E-10 3.19E-1 0 3.01 E-10 2.84E-1 0 2.68E-1 0 2.54E-1 0 2.41 E-10 NE 2.22E-1 0 2.09E-10 1.97E-1 0 1.86E-10 1.75E-10 1.66E-10 1.57E-1 0 ENE 2.89E-1 0 2.72E-1 0 2.56E-1 0 2.42E-10 2.28E-1 0 2.16E-10 2.05E-1 0 E 6.17E-10 5.80E-1 0 5.46E-1 0 5.16E-10 4.87E-1 0 4.61 E-1 0 4.37E-1 0 ESE 1.12E-09 1.06E-09 9.95E-1 0 9.39E-1 0 8.87E-10 8.40E-10 7.96E-1 0 SE 1.22E-09 1.15E-09 1.08E-09 1.02E-09 9.64E-1 0 9.12E-10 8.65E-1 0 SSE 5.83E-1 0 5.48E-1 0 5.16E-10 4.87E-1 0 4.60E-1 0 4.36E-10 4.13E-10 S 2.73E-10 2.57E-1 0 2.42E-10 2.28E-1 0 2.16E-1 0 2.04E-10 1.94E-10 SSW 2.OOE-10 1.88E-10 1.78E-10 1.67E-10 1.58E-10 1.50E-10 1.42E-10 SW 2.16E-10 2.03E-10 1.92E-10 1.81 E-10 1.71 E-10 1.62E-10 1.53E-10 WSW 2.40E-10 2.25E-1 0 2.12E-10 2.OOE-1 0 1.89E-10 1.79E-10 1.70E-1 0 W 5.01 E-10 4.71E-10 4.44E-10 4.19E-10 3.96E-1 0 3.75E-1 0 3.55E-1 0 WNW 9.53E-1 0 8.96E-1 0 8.44E-1 0 7.96E-10 7.52E-1 0 7.12E-10 6.75E-1 0 NW 7.97E-1 0 7.50E-1 0 7.06E-1 0 6.66E-10 6.29E-10 5.96E-10 5.65E-1 0 NNW 5.55E-1 0 5.22E-10 4.92E-1 0 4.64E-1 0 4.38E-1 0 4.15E-10 3.93E-10 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLANu NUCLEAR GENERATING PLANT
( C H PRtJ.,EDURE
.. !agrr, >><. . NUMBER:
OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 181 of 221 Table A-5 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/Q), 1/M2 , for Long Term Ground Level Releases
> 500 Hrs/Yr or > 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5.0 N 3.63E-10 3.45E-10 3.28E-10 3.13E-10 2.99E-10 2.85E-10 2.73E-10 2.61 E-1 0 NNE 2.29E-1 0 2.17E-10 2.07E-10 1.97E-10 1.88E-1 0 1.80E-10 1.72E-10 1.64E-10 NE 1.49E-10 1.42E-10 1.35E-10 1.29E-1 0 1.23E-10 1.17E-10 1.12E-10 1.07E-10 ENE 1.94E-10 1.85E-10 1.76E-10 1.68E-1 0 1.60E-10 1.53E-10 1.46E-10 1.40E-10 E 4.15E-10 3.94E-1 0 3.75E-1 0 3.58E-1 0 3.41 E-1 0 3.26E-10 3.12E-10 2.98E-10 ESE 7.56E-10 7.18E-10 6.84E-1 0 6.52E-1 0 6.22E 5.94E-1 0 5.68E-1 0 5.43E-1 0 SE 8.21 E-1 0 7.80E-10 7.45E-1 0 7.08E-1 0 6.75E-1 0 6.45E-1 0 6.17E-10 5.90E-1 0 SSE 3.92E-1 0 3.73E-10 3.55E-1 0 3.38E-1 0 3.23E-1 0 3.08E-10 2.94E-1 0 2.82E-1 0 S 1.84E-10 1.75E-10 1.66E-10 1.58E-1 0 1.51 E-10 1.44E-10 1.38E-10 1.32E-1 0 SSW 1.35E-10 1.28E-10 1.22E-1 0 1.16E-10 1.11E-10 1.06E-10 1.01 E-10 9.69E-1 1 SW 1.45E-10 1.38E-10 1.32E-10 1.25E-1 0 1.20E-1 0 1.14E-10 1.09E-10 1.05E-10 WSW 1.61E-10 1.53E-10 1.46E-10 1.39E-1 0 1.33E-10 1.27E-10 1.21 E-10 1.16E-10 W 3.37E-1 0 3.20E-10 3.05E-1 0 2.91 E-10 2.77E-1 0 2.65E-1 0 2.53E-1 0 2.42E-10 WNW 6.41 E-1 0 6.09E-10 5.80E-1 0 5.52E-1 0 5.27E-1 0 5.03E-10 4.81 E-10 4.61E-10 NW 5.36E-1 0 5.1OE-10 4.85E-1 0 4.62E-10 4.41 E-10 4.21 E-1 0 4.03E-1 0 3.85E-10 NNW 3.75E-1 0 3.55E-1 0 3.38E-1 0 3.22E-10 3.07E-1 0 2.93E-1 0 2.80E-1 0 2.68E-1 0 Period of Record: 4/1/77 - 3/31/78
NUMBER:
H
~ ,4,.
- ~~':i~~: OFFSITE DOSE CALCULATION MANUAL (ODCM) REV:
H4 17 S =- ES(-tx Page 182 of 221 4 I~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
THIS PAGE IS LEFT INTENTIONALLY BLANK
C PRAIRIE ISLANu NUCLEAR GENERATING PLANT (. HPRC.IcDURE NUMBER:
. 7 J'Y OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
________________ Page 183 of221 Table A-6 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters for Short Term Ground Level Releases
< 500 HrsNr or < 150 Hrs/QTR for Site Boundary Locations (identified in Table A-2)
Site Boundary Sector Sector xlq (secm 3) Dlq (1/m2)
N 7.09E-05 4.60E-07 NNE 7.32E-05 4.11 E-07 NE 1.60E-05 6.77E-08 ENE 1.97E-05 1.11 E-07 E 4.92E-05 1.99E-07 ESE 6.40E-05 2.52E-07 SE 5.98E-05 2.43E-07 SSE 8.79E-05 3.08E-07 S 5.18E-05 2.04E-07 SSW 5.26E-05 1.89E-07 SW 5.25E-05 1.90E-07 WSW 7.83E-05 2.44E-07 W 1.32E-04 3.78E-07 WNW 1.1 OE-04 4.61 E-07 NW 7.67E-05 3.25E-07 NNW 4.79E-05 2.34E-07 Period of Record: 4/1/77 - 3/31/78
NUMBER:
H OFFSITE DOSE CALCULATION MANUAL (ODCM) REV:
H4 17 Page 184 of 221 JI THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAL NUCLEAR GENERATING PLANT C CD H PRO..cDURE
- >> NUMBER:
^ . .: 0Vt ................ .n. . .
OFFSITE DOSE CALCULATION H4 HIa.w7t;>. .. MANUAL j (ODCM) REV: 17 Page 185 of 221 Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/q), sec/r 3 , for'Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Se'ctor I0.1- 0.2 0.3 0.4 0.5 0.6 0.7 N 3.76E-04 1,13E-04 6.59E-05 4.39E-05 3.15E-05 2.47E-05 1.90E-05' NNE 3.35E-04 1.05E-04 5.94E-05' 3.93E-05 2.77E-05 2.19E-05 1.65E-05, NE 4.38E-04' 1.33E-04 7.71 E-05' 4.94E-05 3.39E-05 2.68E-05 2.12E-05 ENE 3.27E-04 1.02E-04 5.93E-05 4.01 E-05 2.80E-05 2.:19E-05 1.69E-05 E 8.12E-04 2.43E-04 1.39E-04 8.80E-05 6.16E-05 4.84E-05 3.78E-05 ESE 1.17E-03 3.52E-04 1.98E-04 1.27E-04 8.80E-05 6.84E-05 5.32E-05 SE 1.27E-03 3.85E-04 2.06E-04' 1.31 E-04 9.32E-05 7.34E-05 5.67E-05 SSE 5.30E-04 2.82E-04 1.57E-04 9.85E-05 6.75E-05 5.39E-05 4.30E-05 S 5.01 E-04 1.57E-04 8.75E-05 5.74E-05 3.97E-05 3.I1 E-05 2.51 E-05 SSW 4.54E-04 1.43E-04 8.26E-05 5.34E-05 3.60E-05 2.85E-05 2.31 E-05 SW 4.46E-04 1.44E-04 8.25E-05 5.30E-05 3.58E-05 2.85E-05 2.35E-05 WSW 6.1 OE-04 1.95E-04 1.08E-04 6.78E-05 4.59E-05 3.67E-05 3.05E-05 W 1.OOE-03 3.1 OE-04 1.74E-04 1.1 OE-04 7.59E-05 6.07E-05 4.89E-05 WNW 8.70E-04 2.65E-04 1.50E-04 9.70E-05 6.86E-05 5.33E-05 4.17E-05 NW 8.41 E-04 2.50E-04 1.38E-04 8.89E-05 6.37E-05 4.97E-05 3.84E-05 NNW 5.69E-04 1.71 E-04 9.73E-05 6.28E-05 4.54E-05 3.55E-05 2.78E-05 Period of Record: 4/1/77 - 3/31/78
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/q), sec/m 3 , for Short Term Ground Level Releases
< 500 Hrs/Yr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 0.8 0.9 1.0 1.1 1.2 1.3 - 1.4 N 1.57E-05 1.26E-05 1.06E-05 8.97E-06 7.73E-06 6.76E-06 5.91 E-06 NNE 1.35E-05 1.11E-05 9.26E-06 7.87E-06 6.81 E-06 5.96E-06 5.27E-06 NE 1.74E-05 1.44E-05 1.21 E-05 1.02E-05 8.57E-06 7.50E-06 6.63E-06 ENE 1.39E-05 1.14E-05 9.46E-06 8.04E-06 6.83E-06 5.97E-06 5.27E-06 E 3.1 1E-05 2.51 E-05 2.11 E-05 1.80E-05 1.53E-05 1.33E-05 1.18E-05 ESE 4.35E-05 3.58E-05 2.98E-05 2.54E-05 2.19E-05 1.91 E-05 1.71 E-05 SE 4.65E-05 3.79E-05 3.18E-05 2.71 E-05 2.32E-05 2.03E-05 1.81 E-05 SSE 3.53E-05 2.87E-05 2.41 E-05 2.05E-05 1.72E-05 1.51 E-05 1.35E-05 S 2.05E-05 1.66E-05 1.38E-05 1.17E-05 1.01 E-05 8.83E-06 7.81 E-06 SSW 1.89E-05 1.54E-05 1.29E-05 1.1OE-05 9.05E-06 7.93E-06 7.02E-06 SW 1.95E-05 1.54E-05 1.30E-05 1.12E-05 9.19E-06 8.05E-06 7.21 E-06 WSW 2.51 E-05 2.05E-05 1.72E-05 1.47E-05 1.21 E-05 1.06E-05 9.41 E-06 W 4.01 E-05 3.24E-05 2.70E-05 2.30E-05 1.89E-05 1.65E-05 1.46E-05 WNW 3.44E-05 2.75E-05 2.31 E-05 1.96E-05 1.68E-05 1.48E-05 1.31 E-05 NW 3.15E-05 2.57E-05 2.17E-05 1.85E-05 1.60E-05 1.40E-05 1.24E-05 NNW 2.28E-05 1.86E-05 1.54E-05 1.31 E-05 1.12E-05 9.85E-06 8.82E-06 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAL NUCLEAR GENERATING PLANT ( H PRt..eDURE NUMBER:
H4
-i§>Se'sit' U. ^a'S,.Y OFFSITE DOSE CALCULATION 11.!r ~MANUAL (ODCM) REV: 17 Page 187 of 221 Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (x/q), sec/m 3 , for Short Term Ground Level Releases 500 HrsNr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 1 5- 1.6 1.7 1.8 1.9 2.0 2.1 N 5.27E-06 4.74E-06 4.30E-06 3.91 E-06 3.59E-06 3.32E-06 3.07E-06 NNE 4.70E-06 4.22E-06 3.82E-06 3.47E-06 3.18E-06 2.97E-06 2.75E-06 NE 5.89E-06' 5.30E-06 4.80E-06 4.37E-06 4.01 E-06 3.69E-06 3.42E-06 ENE 4.67E-06 4.21 E-06 3.80E-06 3.45E-06 3.16E-06 2.91 E-06 2.70E-06 E 1.06E-05 9.52E-06 8.66E-06 7.90E-06 7.25E-06 6.74E-06 6.25E-06 ESE 1.52E-05 1.38E-05 1.25E-05 1.13E-05 1.04E-05 9.72E-06 9.03E-06 SE 1.62E-05 1.46E-05 1.33E-05 1.21 E-05 1.11E-05 1.03E-05 9.59E-06 SSE 1.20E-05 1.09E-05 9.84E-06 8.96E-06 8.23E-06 7.58E-06 7.04E-06 S 6.97E-06 6.27E-06 5.68E-06 5.18E-06 4.75E-06 4.36E-06 4.04E-06 SSW 6.28E-06. 5.66E-06 5.14E-06 4.69E-06 4.31 E-06 3.92E-06 3.64E-06 SW 8.43E-06 5.78E-06 5.24E-06 4.77E-06 4.37E-06 3.90E-06 3.62E-06 WSW 8.41 E-06 7.58E-06 6.87E-06 6.27E-06 5.77E-06 5.17E-06 4.80E-06 W 1.30E-05 1.17E-05 1.06E-05 9.62E-06 8.83E-06 8.33E-06 7.73E-06 WNW 1.17E-05 1.05E-05 9.65E-06 8.80E-06 8.08E-06 7.42E-06 6.89E-06 NW 1.11E-05 1.OOE-05 9.09E-06 8.30E-06 7.63E-06 7.13E-06 6.62E-06 NNW 7.89E-06 7.11E-06 6.47E-06 5.89E-06 5.41 E-06 5.01 E-06 4.64E-06 Period of Record: 4/1/77 - 3/31/78
NUMBER:
H4 mM Lj OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 188 of 221 I _ _ _ _ _ _ _ _ _
Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/q), sec/m 3 , for Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 2.2 2.3 2.4 2.5 2.6 2.7 2.8 N 2.87E-06 2.67E-06 2.50E-06 2.32E-06 2.27E-06 1.94E-06 1.84E-06 NNE 2.56E-06 2.39E-06 2.24E-06 2.09E-06 2.03E-06 1.76E-06 1.66E-06 NE 3.19E-06 2.98E-06 2.79E-06 2.63E-06 2.57E-06 2.24E-06 2.11E-06 ENE 2.51 E-06 2.34E-06 2.19E-06 2.05E-06 1.97E-06 1.74E-06 1.64E-06 E 5.82E-06 5.44E-06 5.1OE-06 4.89E-06 4.75E-06 4.14E-06 3.92E-06 ESE 8.41 E-06 7.87E-06 7.38E-06 7.16E-05 7.09E-06 6.11E-06 5.78E-06 SE 8.93E-06 8.35E-06 7.82E-06 7.70E-05 7.60E-06 6.62E-06 6.26E-06 SSE 6.56E-06 6.14E-06 5.76E-06 5.55E-06 5.36E-06 4.73E-06 4.47E-06 S 3.76E-06 3.51 E-06 3.29E-06 3.18E-06 3.06E-06 2.73E-06 2.59E-06 SSW 3.39E-06 3.16E-06 2.96E-06 2.89E-06 2.75E-06 2.42E-06 2.28E-06 SW 3.37E-06 3.15E-06 2.95E-06 2.84E-06 2.70E-06 2.44E-06 2.30E-06 WSW 4.47E-06 4.18E-06 3.92E-06 3.85E-06 3.67E-06 3.28E-06 3.1OE-06 W 7.21 E-06 6.74E-06 6.32E-06 6.45E-06 6.03E-06 5.30E-06 5.02E-06 WNW 6.42E-06 6.OOE-06 5.65E-06 5.32E-06 5.23E-06 4.55E-06 4.30E-06 NW 6.16E-06 5.76E-06 5.40E-06 5.16E-06 5.03E-06 4.37E-06 4.13E-06 NNW 4.31 E-06 4.02E-06 3.76E-06 3.57E-06 3.46E-06 3.OOE-06 2.83E-06 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAND NUCLEAR GENERATING PLANT
( C H PRCAFDURE
'+ 0'@$'K2t t5t+t5N4>fiXZ-5X8w>)Z<iiz ~~~~~NUMBER:
OFFSITE DOSE CALCULATION H4
[I 7rtl<R}9Ju$lzignl4^inv g MANUAL (ODCM) REV: 17
.i'iE
_________.,_______> & 2 Page 189 of 221 Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/q), sec/m 3 , for Short Term Ground Level Releases
< 500 HrsNr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
-- Miles Sector 2.9 3.0 3.1 3.2 3.3 3.4 3.5 N 1.74E-06 1.66E-06 1.58E-06 1.50E-06 1.43E-06 1.37E-06 1.31 E-06 NNE 1.57E-06 1.50E-06 1.43E-06 1.36E-06 1'.30E-06 1.24E-06 1.19E-06 NE 2.OOE-06 1.9bE-06 1.81 E-06 1.73E-06 1.65E-06' 1.58E-06 1.51 E-06 ENE 1.55E-06 1.48E-06 1.40E-06 1.33E-06 1.27E-06 1.21 E-06 1.16E-06 E 3.71 E-06 3.51 E-06 3.34E-06' 3.19E-06 3.04E-06 2.91 E-06 2.79E ESE 5.48E-06 5.18E-06 4.93E-06 4.70E-05 4.49E-06 4.29E-06 4.11 E-06' SE5 5.93E-06 5.63E-06 5.36E-06 5.11E-05 4.87E-06 4.66E-06 4.46E-06 SSE 4.24E-06 3.97E-06 3.78E-06 3.60E-06 3.44E-06 3.29E-06 3.15E-06 S 2.45E-06 2.25E-06 2.14E-06 2.04E-06 1.94E-06 i.85E-06 1.77E-06 SSW 2.16E-06 1.96E-06 1.87E-06 1.78E-06 1.70E-06 1.63E-06 1.56E-06 SW 2.18E-06 2.03E-06 1.93E-06 1.84E-06 1.75E-06 1.67E-06 1.60E-06 WSW 2.94E-06 2.70E-06 2.57E-06 2.45E-06 2.34E-06 2.24E-06 2.14E-06 W 4.76E-06 4.34E-06 4.13E-06 3.95E-06 3.77E-06 3.61 E-06 3.47E-06 WNW 4.07E-06 3.86E-06 3.67E-06 3.50E-06 3.34E-06 3.20E-06 3.06E-06 NW 3.92E-06 3.69E-06 3.51 E-06 3.35E-06 3.20E-06 3.06E-06 2.94E-06 NNW 2.68E-06 2.53E-06 2.40E-06 2.28E-06 2.18E-06 2.08E-06 1.99E-06 Period of Record: 4/1/77 - 3/31/78
NUMBER:
- 2. -
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 190 of 221 Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/q), sec/m 3 , for Short Term Ground Level Releases
<500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 3.6 3.7 3.8 3.9 4.0 4.1 4.2 N 1.25E-06 1.20E-06 1.15E-06 1.10E-06 1.06E-06 1.02E-06 9.88E-07 NNE 1.14E-06 1.09E-06 1.05E-06 1.01 E-06 9.73E-07 9.37E-07 9.04E-07 NE 1.45E-06 1.39E-06 1.34E-06 1.29E-06 1.24E-06 1.20E-06 1.16E-06 ENE 1.11E-06 1.07E-06 1.02E-06 9.83E-07 9.46E-07 9.11E-07 8.79E-07 E 2.67E-06 2.57E-06 2.47E-06 2.38E-06 2.29E-06 2.21 E-06 2.13E-06 ESE 3.94E-06 3.78E-06 3.64E-06 3.50E-06 3.38E-06 3.26E-06 3.15E-06 SE5 4.27E-06 4.10 E-06 3.94E-06 3.79E-06 3.65E-06 3.52E-06 3.39E-06 SSE 3.02E-06 2.90E-06 2.79E-06 2.68E-06 2.59E-06 2.50E-06 2.41 E-06 S 1.70E-06 1.63E-06 1.57E-06 1.51 E-06 1.45E-06 1.40E-06 1.35E-06 SSW 1.50E-06 1.44E-06 1.38E-06 1.33E-06 1.29E-06 1.24E-06 1.20E-06 SW 1.53E-06 1.47E-06 1.41 E-06 1.36E-06 1.29E-06 1.25E-06 1.20E-06 WSW 2.06E-06 1.98E-06 1.90E-06 1.83E-06 1.76E-06 1.70E-06 1.64E-06 W 3.33E-06 3.20E-06 3.08E-06 2.97E-06 2.87E-06 2.77E-06 2.68E-06 WNW3 2.93E-06 2.81 E-06 2.70E-06 2.60E-06 2.51 E-06 2.42E-06 2.33E-06 NW 2.82E-06 2.71 E-06 2.60E-06 2.50E-06 2.41 E-06 2.32E-06 2.24E-06 NNW 1.91 E-06 1.83E-06 1.76E-06 1.69E-06 1.63E-06 1.57E-06 1.52E-06 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLANu NUCLEAR GENERATING PLANT
( H PRLeDURE NUMBER:
OFFSITE DOSE CALCULATION H4
'11,jMANUAL(00CM) REV: 17 Page 191 of 22 Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (/q), sec/m 3 , for Short Term Ground Level Releases
< 500 HrsNr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 4.3 4.4 4.5 4.6 4.7 4.8 4.9 N 9.59E-07 9.27E-07 8.97E-07 8.68E-07 8.41 E-07 8.16E-07 7.92E-07 NNE 8.73E-07 8.44E-07 8.16E-07 7.90E-07 7.65E-07 7.42E-07 7.20E-07 NE 1.12E-06 1.08E-06 1.05E-06 1.01E-06 9.18E-07 9.51 E-07 9.23E-07 ENE 8.47E-07 8.18E-07 7.91 E-07 7.66E-07 7.41 E-07 7.18E-07 6.97E-07 E 2.06E-06 2.OOE-06 1.93E-06 1.87E-06 1.82E-06 1.76E-06 1.71 E-06 ESE 3.04E-06 2.94E-06 2.85E-06 2.76E-06 2.67E-06 2.60E-06 2.52E-06 SE5 3.27E-06 3.16E-06 3.06E-06 2.97E-06 2.88E-06 2.79E-06 2.70E-06 SSE 2.34E-06 2.26E-06 2.19E-06 2.12E-06 2.07E-06 2.01 E-06 1.95E-06 S 1.30E-06 1.26E-06 1.22E-06 1.18E-06 1.15E-06 1.11E-06 1.08E-06 SSW 1.16E-06 1.12E-06 1.09E-06 1.05E-06 1.02E-06 9.94E-07 9.66E-07 SW 1.16E-06 1.12E-06 1.09E-06 1.05E-06 1.02E-06 9.91 E-07 9.62E-07 WSW 1.59E-06 1.54E-06 1.49E-06 1.44E-06 1.39E-06 1.35E-06 1.31 E-06 W 2.59E-06 2.51 E-06 2.43E-06 2.36E-06 2.29E-06 2.23E-06 2.17E-06 WNW3 2.25E-06 2.18E-06 2.11E-06 2.04E-06 1.98E-06 1.92E-06 1.86E-06 NW 2.16E-06 2.09E-06 2.01 E-06 1.95E-06 1.89E-06 1.84E-06 1.79E-06 NNW 1.46E-06 1.41 E-06 1.36E-06 1.32E-06 1.28E-06 1.24E-06 1.20E-06 Period of Record: 4/1/77 - 3/31/78
-.11-1111,, "-4, NUMBER:
?4- z v-,,', ,,
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 192 of 221 I ___________________________________
Table A-7 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (Iq), sec/m 3 , for Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 5.0 N 7.67E-07 NNE 6.99E-07 NE 8.97E-07 ENE 6.76E-07 E 1.67E-06 ESE 2.45E-06 SE 2.62E-06 SSE 1.89E-06 S 1.05E-06 SSW 9.39E-07 SW 9.35E-07 WSW 1.27E-06 W 2. 1E-06 WNW 1.81 E-06 NW 1.74E-06 NNW 1.17E-06 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAhu NUCLEAR GENERATING PLANT (. C H PRUL.EDURE NUMBER:
'lUnIigssast OFFSITE DOSE CALCULATION H4
,^'YU;§g ,l MANUAL (ODCM) REV: 17 Page 193 of 221 Table A-8 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q), 1/M2, for Short Term Ground Level Releases
<500 HrsNr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector '0.1 ' 0.2 0.3 0.4 0.5 0.6 0.7 N 1.68E-06 6.63E-07 4.32E-07 3.OOE-07 2.18E-07 1.69E-07 1.29E-07 NNE 1.33E-06 5.43E-07 3.46E-07 2.40E-07 1.72E-07 1.36E-07 1.03E-07 NE' 1.19E-06 4.68E-07 3.05E-07 2.06E-07 1.45E-07 1.14E-07 9.1OE-08 ENE 1.20E-06 4.86E-07 3.17E-07 2.23E-07 1.58E-07 1.23E-07 9.49E-08 E 2.08E-06 8.09E-07 5.21 E-07 3.46E-07 2.49E-07. 1.96E-07 1.54E-07 ESE 2.90E-06 1.14E-06 7.17E-07 4.85E-07 3.45E-07 2.69E-07 2.11E-07 SE 3.20E-06 1.26E-06 7.54E-07 5.08E-07 3.71 E-07 2.94E-07 2.31 E SSE 2.09E-06 8.24E-07 5.16E-07 3.41 E-07 2.40E-07 1.92E-07 1.55E-07 S 1.27E-06 5.18E-07 3.24E-07 2.23E-07 1.58E-07 1.23E-07 1.OOE-07
'SSW 1.06E-06 4.33E-07 2.82E-07 1.92E-07 1.33E-07 1.05E-07 8.51 E-08 SW 1.05E-06 4.42E-07 2.85E-07 1.91 E-07 1.31 E-07 1.04E-07 8.55E-08 WSW 1.24E-06 5.19E-07 3.24E-07 2.14E-07 1.48E-07 1.19E-07 1.94E-08 W 1.90E-06 7.65E-07 4.83E-07 3.22E-07 2.27E-07 1.82E-07 1.48E-07 WNW 2.42E-06 9.62E-07 6.1 OE-07 4.14E-07 2.99E 2.31 E-07 1.81 E-07 NW 2.30E-06 8.91 E-07 5.49E-07 3.72E-07 2.73E-07 2.12E-07 1.65E-07 NNW 1.79E-06 7.01 E-07 4.46E-07 3.01 E-07 2.21 E-07 1.72E-07 1.34E-07 Period of Record: 4/1/77 - 3/31/78
, R:""",'W,4 NUMBER:
11, 1 11,,, " "
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 194 of 221 L
Table A-8 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q),1/r 2 , for Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 0.8 0.9 1.0 1.1 1.2 1.3 1.4 N 1.05E-07 8.25E-08 6.73E-08 5.55E-08 4.66E-08 3.99E-08 3.41 E-08 NNE 8.35E-08 6.76E-08 5.48E-08 4.55E-08 3.85E-08 3.29E-08 2.85E-08 NE 7.39E-08 5.99E-08 4.95E-08 4.08E-08 3.35E-08 2.87E-08 2.49E-08 ENE 7.67E-08 6.15E-08 4.97E-08 4.13E-08 3.42E-08 2.93E-08 2.53E-08 E 1.25E-07 9.96E-08 8.17E-08 6.79E-08 5.63E-08 4.82E-08 4.18E-08 ESE 1.71 E-07 1.38E-07 1.12E-07 9.32E-08 7.87E-08 6.71 E-08 5.86E-08 SE 1.88E-07 1.50E-07 1.23E-07 1.02E-07 8.55E-08 7.34E-08 6.38E-08 SSE 1.26E-07 1.01E-07 8.26E-08 6.86E-08 5.63E-08 4.83E-08 4.22E-08 S 8.06E-08 6.40E-08 5.16E-08 4.29E-08 3.60E-08 3.07E-08 2.66E-08 SSW 6.87E-08 5.49E-08 4.50E-08 3.73E-08 3.OOE-08 2.57E-08 2.23E-08 SW 7.OOE-08 5.41 E-08 4.47E-08 3.73E-08 3.OOE-08 2.57E-08 2.25E-08 WSW 8.11 E-08 6.49E-08 5.32E-08 4.44E-08 3.59E-08 3.08E-08 2.67E-08 W 1.21 E-07 9.57E-08 7.80E-08 6.48E-08 5.22E-08 4.46E-08 3.86E-08 WNW 1.47E-07 1.15E-07 9.45E-08 7.80E-08 6.54E-08 5.61 E-08 4.86E-08 NW 1.34E-07 1.07E-07 8.78E-08 7.30E-08 6.13E-08 5.23E-08 4.53E-08 NNW 1.08E-07 8.62E-08 6.96E-08 5.74E-08 4.82E-08 4.12E-08 3.60E-08 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLANu NUCLEAR GENERATING PLANT ( H PRL_dDURE TABLE A-8 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q), 1/M2, for Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 1.5 1.6 1.7 1.8 1.9 2.0 2.1 N 2.98E-08 2.62E-08 2.33E-08 2.08E-08 1.87E-08 1.70E-08 1.54E-08 NNE 2.49E-08 2.20E-08 1.95E-08 1.74E-08 1.56E-08 1.43E-08 1.30E-08 NE 2. 17E-08 1.92E-08, 1.70E-08 1.52E-08 1.37E-08 1.23E-08 1.12E-08 ENE 2.20E-087 1.94E-08 1.72E-08 1.54E-08 1.38E-08 1.25E-08 1.13E-08 E 3.66E-08 3.24E-08 2.89E-08 2.58E-08 2.32E-08 2.11E-08 1.91 E-08 ESE 5.12E-08 4.53E-08 4.03E-08 3.60E-08 3.23E-08 2.95E-08 2.68E-08 SE - 5.61 E-08 4.96E-08 4.41 E-08 3.95E-08 3.55E-08 3.21 E-08 2.92E-08 SSE 3.70E-08 3.27E-08 2.91 E-08 2.60E-08 2.34E-08 2.1 OE-08 1.91 E-08.
S 2.32E-08 2.05E-08 1.82E-08 1.63E-08 1.46E-08 1.31 E-08 1.19E-08 SSW 1.95E-08 1.73E-08 1.54E-08 1.38E-08 1.24E-08 1.1OE-08 1.OOE-08
.SW' 1.97E-08 1.74E-08 1.54E-08 1.38E-08 1.24E-08 1.08E-08 9.86E-09 WSW 2.34E-08 2.07E-08 1.84E-08 1.65E-08 1.49E-08 1.30E-08 1.18E-08 Ww W 3.37E-08 2.97E-08 2.64E-08 2.36E-08 2.12E-08 1.95E-08 1.77E-08 WNW 4.26E-08: 3.76E-08 3.38E-08 3.02E-08 2.72E-08 2.44E-08 2.22E-08 NW 3.97E-08 3.51 E-08 3.12E-08 2.80E-08 2.52E-08 2.30E-08 2.09E-08 NNW 3.15E-08 2.78E-08 2.48E-08 2.22E-08 1.99E-08 1.81 E-08 1.64E-08 Period of Record: 4/1/77 - 3/31/78
NUMBER:
H4 K: OFFSITE DOSE CALCULATION MANUAL (ODCM) REV: 17 Page 196 of 221 I1 Table A-8 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q), 1/M2, for Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 2.2 2.3 2.4 2.5 2.6 2.7 I 2.8 N 1.41 E-08 1.29E-08 1.19E-08 1.09E-08 1.05E-08 8.80E-09 8.23E-09 NNE 1.18E-08 1.08E-08 9.96E-09 9.12E-09 8.70E-09 7.42E-09 6.90E-09 NE 1.02E-08 9.34E-09 8.58E-09 7.92E-09 7.61 E-09 6.51 E-O9 6.05E-09 ENE 1.03E-08 9.45E-09 8.69E-09 7.99E-09 7.58E-09 6.56E-09 6.10E-09 E 1.74E-08 1.60E-08 1.47E-08 1.38E-08 1.32E-08 1.13E-08 1.05E-08 ESE 2.44E-08 2.24E-08 2.05E-08 1.96E-08 1.90E-08 1.61 E-08 1.50E-08 SE 2.66E-08 2.43E-08 2.24E-08 2.16E-08 2.09E-08 1.79E-08 1.66E-08 SSE 1.74E-08 1.60E-08 1.47E-08 1.39E-08 1.32E-08 1.14E-08 1.06E-08 S 1.09E-08 9.97E-09 9.17E-09 8.70E-09 8.23E-09 7.22E-09 6.73E-09 SSW 9.14E-09 8.37E-09 7.70E-09 7.37E-09 6.91 E-09 5.96E-09 5.54E-09 SW 9.OOE-09 8.25E-09 7.60E-09 7.18E-09 6.72E-09 5.98E-09 5.56E-09 WSW 1.08E-08 9.89E-09 9.09E-09 8.77E-09 8.21 E-09 7.20E-09 6.69E-09 W 1.62E-08 1.48E-08 1.36E-08 1.36E-08 1.25E-08 1.08E-08 1.OOE-08 WNW 2.02E-08 1.86E-08 1.71 E-08 1.59E-08 1.53E-08 1.31 E-08 1.22E-08 NW 1.90E-08 1.74E-08 1.60E-08 1.51 E-08 1.44E-08 1.23E-08 1.14E-08 NNW 1.50E-08 1.37E-08 1.26E-08 1.17E-08 1.12E-08 9.53E-09 8.86E-09 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLANu NUCLEAR GENERATING PLANT C HPRQ.;DURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 197 of 221 Table A Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q),1/r 2 , for Short Term Ground Level Releases
< 500 HrsNr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 2.9 3.0 3.1 3.2 -3.3 3.4 3.5 N 7.68E-09 7.22E-09 6.76E-09 6.35E-09 5.97E-09 5.63E-09 5.31 E-09.
NNE 6.44E-09 6.04E-09 5.66E-09 5.32E-09 5.OOE-09 4.72E-09 4.46E-09 NE 5.64E-09 5.27E-09 4.94E-09 4.64E-09 4.36E-09 4.11E-09 3.89E-09 ENE 5.69E-09 5.33E-09 5.00E-09 4.69E-09 4.41 E-09 4.16E-09 3.92E-09 E 9.78E-09 9.1 OE-09 8.52E-09 8.00E-09 7.52E-09 7.09E-09 6.69E-09 ESE 1.39E-08 1.30E-08 1.21 E-08 1.14E-08 1.07E-08 1.01 E-08 9.53E-09 SE 1.55E-08 1.44E-08 1.35E-08 1.27E-08 1.19E-08 1.12E-08 1.06E-08 SSE 9.88E-09 9.11E-09 8.52E-09 8.00E-09 7.52E-09 7.08E-09 6.69E-09 S 6.27E-09 5.67E-09 5.31 E-09 4.98E-09 4.68E-09 4.41 E-09 4.16E-09 SSW 5.1 6E-09 4..61 E-09 4.32E-09 4.06E-09 3.82E-09 3.61 E-09 3.41 E-09 SW 5.18E-09 4.74E-09 4.45E-09 4.17E-09 3.93E-09 3.70E-09 3.50E-09 WSW 6.24E-09 5.64E-09 5.28E-09 4.96E-09 4.67E-09 4.40E-09 4.16E-09 W 9.36E-09 8.39E-08 7.87E-09 7.40E-09 6.97E-09 6.58E-09 6.22E-09 WNW 1.13E-08 1.06E-08 9.92E-09 9.31 E-09 8.76E-09 8.27E-09 7.81 E-09 NW 1.07E-08 9.88E-09 9.26E-09 8.70E-09 8.19E-09 7.72E-09 7.31 E-09 NNW 8.26E-09 7.66E-09 7.17E-09 6.73E-09 6.33E-09 5.97E-09 5.63E-09 Period of Record: 4/1/77 - 3/31/78
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
Table A-8 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q), 1/M2 , for Short Term Ground Level Releases
< 500 Hrs/Yr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 3.6 3.7 3.8 3.9 4.0 4.1 4.2 N 5.01 E-09 4.75E-09 4.50E-09 4.28E-09 4.07E-09 3.88E-09 3.70E-09 NNE 4.22E-09 4.OOE-09 3.79E-09 3.60E-09 3.42E-09 3.26E-09 3.11E-09 NE 3.68E-09 3.49E-09 3.31 E-09 3.15E-09 3.OOE-09 2.85E-09 2.72E-09 ENE 3.71 E-09 3.51 E-09 3.33E-09 3.17E-09 3.01 E-09 2.87E-09 2.74E-09 E 6.33E-09 6.OOE-09 5.69E-09 5.41 E-09 5.15E-09 4.91 E-09 4.68E-09 ESE 9.02E-09 8.54E-09 8.1 OE-09 7.70E-09 7.32E-09 6.98E-09 6.66E-09 SE 9.99E-09 9.46E-09 8.96E-09 8.51 E-09 8.09E-09 7.70E-09 7.33E-09 SSE 6.33E-09 5.99E-09 5.68E-09 5.40E-09 5.14E-09 4.90E-09 4.67E-09 S 3.94E-09 3.73E-09 3.54E-09 3.36E-09 3.20E-09 3.05E-09 2.91 E-09 SSW 3.23E-09 3.06E-09 2.91 E-09 2.77E-09 2.64E-09 2.51 E-09 2.40E-09 SW 3.31 E-09 3.14E-09 2.98E-09 2.83E-09 2.66E-09 2.53E-09 2.42E-09 WSW 3.94E-09 3.73E-09 3.54E-09 3.37E-09 3.21 E-09 3.06E-09 2.92E-09 W 5.89E-09 5.59E-09 5.31 E-09 5.05E^09 4.81 E-09 4.59E-09 4.38E-09 WNW 7.39E-09 7.00E-09 6.64E-09 6.31 E-09 6.OOE-09 5.72E-09 5.45E-09 NW 6.93E-09 6.56E-09 6.23E-09 5.92E-09 5.63E-09 5.36E-09 5.11E-09 NNW 5.33E-09 5.05E-09 4.79E-09 4.58E-09 4.34E-09 4.13E-09 3.94E-09 Period of Record: 411/77 - 3/31/78
C PRAIRIE ISLANu NUCLEAR GENERATING PLANT C H PRU.EDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 199 of 221 Table A-8 Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q), 1/M2, for Short Term Ground Level Releases
< 500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 4.3 4.4 4.5 4.6 4.7 4.8 4.9 N 3.55E-09 3.40E-09 3.26E-09 3.12E-09 2.99E-09 2.87E-09 2.76E-09 NNE 2.97E-09 2.84E-09 2.71 E-09 2.60E-09 2.49E-09 2.39E-09 2.30E-09 NE 2.60E-09 2.48E-09 2.37E-09 2.27E-09 2.18E-09 2.09E-09 2.01 E-09 ENE 2.61E-09 2.49E-09 2.39E-09 2.29E-09 2.19E-09 2.1OE-09 2.02E-09 E 4.48E-09 4.28E-09 4.1 OE-09 3.93E-09 3.77E-09 3.62E-09 3.47E-09 ESE 6.35E-09 6.07E-09 5.81E-09 5.57E-09 5.34E-09 5.13E-09 4.92E-09 SE 6.99E-09 6.68E-09 6.38E-09 6.12E-09 5.86E-09 5.62E-09 5.38E-09 SSE 4.48E-09 4.28E-09 4.1 OE-09 3.93E-09 3.78E-09 3.63E-09 3.48E-09 S 2.78E-09 2.65E-09 2.54E-09 2.43E-09 2.34E-09 2.24E-09 2.15E-09 SSW 2.30E-09 2.20E-09 2.11 E-09 2.02E-09 1.94E-09 1.86E-09 1.79E-09 SW 2.31E-09 2.21E-09 2.12E-09 2.03E-09 1.95E-09 1.87E-09 1.80E-09 WSW 2.79E-09 2.67E-09 2.55E-09 2.45E-09 2.33E-09 2.24E-09 2.15E-09 W 4.19E-09 4.01E-09 3.84E-09 3.69E-09 3.54E-09 3.40E-09 3.27E-09 WNW 5.20E-09 4.98E-09 4.76E-09 4.57E-09 4.38E-09 4.21 E-09 4.04E-09 NW 4.88E-09 4.66E-09 4.44E-09 4.25E-09 4.08E-09 3.92E-09 3.77E-09 NNW 3.76E-09 3.60E-09 3.43E-09 3.29E-09 3.16E-09 3.03E-09 2.9-1 E-09 Period of Record: 4/1/77 - 3/31/78
NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM)
Table A Prairie Island Dispersion Parameters Prairie Island Dispersion Parameters (D/q), 1/M2 , for Short Term Ground Level Releases
<500 HrsYr or < 150 Hrs/QTR for Standard Distances (As Measured from Edge of Plant Complex)
Miles Sector 5.0 N 2.65E-09 NNE 2.21 E-09 NE 1.93E-09 ENE 1.94E-09 E 3.34E-09 ESE 4.73E-09 SE 5.17E-09 SSE 3.35E-09 S 2.07E-09 SSW 1.73E-09 SW 1.73E-09 WSW 2.07E-09 W 3.15E-09 WNW 3.89E-09 NW 3.63E-09 NNW 2.80E-09 Period of Record: 4/1/77 - 3/31/78
PRAIRIE ISLAND NUCLEAR GENERATING PLANT .H PROCEDURE:
NUMBER:
H OFFSITE DOSE CALCULATION
~~~~MANUAL,(ODCM) -REV:
H4 1
Page 201 of 221 Appendix B Prairie Island 12.2m Wind and AT42.7-12.2m Stability Joint Frequency Distributions (411177 - 3131178)
PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 4/1/77 THROUGH 3/31/78 STABILITY CLASS A ELEVATION 40 FT.
WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1 TO 3 4 TO 7 8 TO 12 13 TO 18 19 TO 24 ABOVE 24 TOTAL N 7 22 29 11 0 69 NNE 13 19 20 4 0 56 NE 11 35 16 I 0 63 ENE 11 33 20 0 0 64 E 14 37 24 0 0 75 ESE 4 45 49 7 2 107 SE 4 10 22 13 1 50 SSE 1 7 19 12 2 41 S 2 23 45 27 0 97 SSW 1 22 39 14 0 76 SW 2 17 30 3 0 52 WSW 0 21 25 11 .0 57 W 1 29 46 18 2 96 WNW 6 34 64 56 20 181 NW 12 42 72 53 20 199 NNW 11 43 49 20 2 125 VAR 0 0 0 0 0 0 TOTAL HOURS THIS CLASS 1408 HOURS OF CALM THIS CLASS 0 PERCENT OF ALL DATA THIS CLASS 16.81
PRAIRE ISLAND NUCLEAP.GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4
^ MANUAL(ODCM). REV: 17 H MANUAL (ODCM) Page 202 of 221 PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 4/1/77 THROUGH 3/31/78 STABILITY CLASS B ELEVATION 40 FT.
WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1TO3 4TO7 8TO12 13TO18 19TO24 ABOVE24 TOTAL N 3 5 I 0 9 NNE 2 1 0 5 NE 2 0 0 0 2 ENE 3 2 0 0 5 E 1 1 0 0 2 ESE 5. 10 6 0 23 SE 2 8 4 0 16 SSE 3 4 3 0 10 S 0 7 9 0 17 SSW 1 7 0 0 8 SW 4 1 0 0 5 WSW 2 5 I 0 9 W 8 7 3 0 18 WNW 5 8 6 0 23 NW 4 11 10 0 28 NNW 5 3 1 1 11 VAR 0 0 0 0 0 TOTAL HOURS THIS CLASS 191 HOURS OF CALM THIS CLASS 0 PERCENT OF ALL DATA THIS CLASS 2.28
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
_____ Page 203 of 221 PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 4/1/77 THROUGH 3/31/78 STABILITY CLASS C ELEVATION 40 FT.
- WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1 TO3 4 TO 7 8 TO412 13 TO 18 19 TO 24 ABOVE 24 TOTAL N 2 4 4 1 0 0 11 NNE 2 3 I .0 0 0 6 NE 1 5 1 0 0 0 7 ENE 0 3 I 0 0 0 4 E 1 8 3 0 0 0 12 ESE 0 7 11 -2 0 0 20 SE 0 2 5 16 0 0 13 SSE 0O 2 6 7 0 16 S 0 2 10 4 0 16 0
SSW 1 6 4 0 0 11
~0 SW 2 2 3 2 0 9 WSW 1 6 5 -I 2 0 15 W 0 2 11 I4 I 0 18 WNW 1 3 6 -7 I 0 18 NW 2 .7 11 .16 6 I1 43 NNW 3 5 -7 3 0 21 VAR I0 "o 0 :0 0 0 TOTAL HOURS THIS CLASS 240 HOURS OF CALM THIS CLASS 0 PERCENT OF ALL DATA THIS CLASS 2.87
PRAJRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE tN tl g F NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 204 of 221 PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 4/1/77 THROUGH 3/31/78 STABILITY CLASS D ELEVATION 40 FT.
WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1 TO 3 4 TO 7 8 TO 12 13 TO 18 19 TO 24 ABOVE 24 TOTAL N 9 24 11 8 0 52 NNE 6 22 9 0 0 37 NE 16 26 4 0 0 46 ENE 11 41 4 0 0 56 E 11 95 27 0 0 133 ESE 8 57 154 19 0 238 SE 10 30 90 38 5 173 SSE 8 40 59 51 10 168 S 1 51 72 17 4 145 SSW 5 29 30 12 0 76 SW 4 15 17 4 0 40 WSW 5 23 31 21 3 87 W 6 53 61 28 6 155 WNW 14 57 76 75 21 243 NW 14 44 72 110 41 281 NNW 16 22 41 25 13 117 VAR 0 0 0 0 0 0 TOTAL HOURS THIS CLASS 2051 HOURS OF CALM THIS CLASS 4 PERCENT OF ALL DATA THIS CLASS 24.49
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 411/77 THROUGH 3/31/78 STABILITY CLASS E ELEVATION 40 FT.
WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1ITO 3 4 TO 7 8 TO 12 13 TO 18 19 TO24 ABOVE 24: TOTAL N 22 30 9 ,101 0 73 NNE 18 29 7 0 54 NE 22 26 7 1 0 56 ENE 19 30 5 1 0 55 E 25 96 10 0 0 131 ESE 28 144 140 27 0 349 SE 24 107 125 41 0 299 SSE 21 67 74 23 0O 185
- S 11 56 73 29 0 170 SSW 3 26 29 40 0 99 SW 14 22 17 12 0 ,65 WSW 14 24 24 11 0 74 W 26 73 48 18 0 166 WNW 46 136 127 44 0 357 NW 46 98 101 62 0 315 NNW -43 53 48 10 0 157 VAR I 0 0 0 0 0 0 TOTAL HOURS THIS CLASS 2612 HOURS OF CALM THIS CLASS 7 PERCENT OF ALL DATA THIS CLASS 31.18
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
Hl 0 i l OFFSITE DOSE CALCULATION MANUAL (ODCM) REV:
H4 17 Page 26o 2 PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 4/1/77 THROUGH 3/31/78 STABILITY CLASS F ELEVATION 40 FT.
WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1TO3 4TO 7 8 TO 12 13 TO 18 19 TO 24 ABOVE 24 TOTAL N 18 8 3 0 29 NNE 11 6 1 0 18 NE 11 5 2 0 18 ENE 13 7 0 0 20 E 29 33 2 0 64 ESE 39 61 9 1 110 SE 38 69 36 3 146 SSE 27 32 17 2 79 S 12 16 21 .7 56 SSW 6 11 17 6 40 SW 5 3 9 4 21 WSW 8 8 8 0 24 W 25 39 12 2 78 WNW 56 63 12 0 131 NW 66 71 16 3 156 NNW 29 19 6 2 56 VAR 0 0 0 0 0 TOTAL HOURS THIS CLASS 1053 HOURS OF CALM THIS CLASS 7 PERCENT OF ALL DATA THIS CLASS 12.57
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 207 of 221 PRAIRIE ISLAND NUCLEAR GENERATING PLANT SITE METEOROLOGY -
FREQUENCY DISTRIBUTION TABLES -
HOURS AT EACH WIND SPEED AND DIRECTION PERIOD: 4/1/77 THROUGH 3/31/78 STABILITY CLASS G ELEVATION 40 FT.
WIND SPEED (MPH) AT 40 FT LEVEL DIRECTION 1 TO 3 4 TO 7 8 TO 12 13 TO 18 19 TO 24 ABOVE 24 TOTAL N 14 5 19 NNE 13 2 16 NE 12 2 15 ENE 22 1 25 E 52 8 62 ESE 50 17 68 SE 37 23 69 SSE 18 8 35 S 11 4 19 SSW 13 2 17 SW 15 5 21
'WSW 10 1 12 W 41 19 61 WNW 75 50 125 NW 80 66 149 NNW 47 19 71 VAR 0 0 0 TOTAL HOURS THIS CLASS 821 HOURS OF CALM THIS CLASS 37 PERCENT OF ALL DATA THIS CLASS 9.80
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 208 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATiNG PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 209 of 221 Appendix C - Dose Parameters for Radioiodines, Particulates and Tritium This appendix contains the methodology which was used to calculate the dose parameters for radioiodines, particulates, and tritium to show compliance with 10CFR20 and Appendix I of 10CFR50 for gaseous effluents. These dose parameters, Pi and R1, were calculated using the methodology outlines in NUREG-0133 along with Regulatory Guide 1.109 Revision 1. The following sections provide the specific methodology which was utilized in calculating the Pi and R1 values for the various exposure pathways.
C.1 Calculation of Pi The parameter, Pi, contained in the radioiodine and particulates portion of Section 5.2, includes pathway transport parameters of the ith radionuclide, the receptor's usage of the pathway media and the dosimetry of the exposure. Pathway usage rates and the internal dosimetry are functions of the receptor's age: however, the child age group, will always receive the maximum dose under the exposure conditions assumed.
C.1.1 Inhalation Pathway Pi1 = K' (BR) DFAi (C.1-1) where:
Pi1 = dose parameter for radionuclide i for the inhalation pathway, mrem/yr per ptci/m3 K' = a constant of unit conversion:
6
- 10 pCi/pCi:
BR = the breathing rate of the child age group, 3
m /yr; DFAi = the maximum organ inhalation dose factor for the child age group for radionuclide i, mrem/pCi.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 210 of 221]
The age group considered is the child group. The child's breathing rate is taken as 3700 m 3 /yr from Table E-5 of Regulatory Guide 1.109 Revision 1. The inhalation dose factors for the child DFAJ, are presented in Table E-9 of Regulatory Guide 1.109 in units of mrem/pCi. The total body is considered as an organ in the selection of DFA. The incorporation of breathing rate of the child and the unit conversion factor results in the following:
Pi 1 = 3.7 x I09 FA (C.1-2)
C.2 Calculation of RI The radioiodine and particulate specification is applicable to the location in the unrestricted area where the combination of existing pathways and receptor age groups indicates the maximum potential exposure occurs. The inhalation and ground plane exposure pathways SHALL be considered to exist at all locations. The grass-goat-milk, the grass-cow-milk, grass-cow-meat, and vegetation pathways are considered based on their existence at the various locations. R values have been calculated for the adult, teen, child, and infant age groups for the ground plane, cow milk, goat milk, vegetable and beef ingestion pathways. The methodology which was utilized to calculate these values is presented below.
C.2.1 Inhalation Pathway R,= K' (BR)a (DFAi)a (C.2-1) where:
RI, = dose factor for each identified radionuclide I of the organ of interest, mrey/yr per [Ci/m 3 K' = a constant of unit conversion:
= 106 pCi/p.Ci; (BR)a = breathing rate of the receptor of age group a, m 3/yr; (DFAi)a = organ inhalation dose factor for radionuclide i for the receptor of age group a, mrem/pCi.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT . H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV:. 17 Page 211 of 221 The breathing'rates (BR)a for the various age groups are tabulated below, as given in Table E-5 of the Regulatory Guide 1.109 Revision 1.
Age Group (a) Breathing Rate (m 3/vr)
I'nfant 1400 Child 3700 Teen 8000 Adult 8000 Inhalation dose factors (DFAj)a for the various age groups are given in Tables E-7 through E-10 of Regulatory Guide 1.109 Revision 1.
C.2.2 Ground Plane Pathway RG = I K'K" (SF) DFGi (1-e` t)/1X (C.2-2) where:
RiG = dose factor for the ground plane pathway for each identified radionuclide i for the organ of interest, m2 -mrem/yr per pCi/sec per; K' = a constant of unit conversion; 6
10 pCi/pCi; K" = a constant of unit conversion;
= 8760 mr/year; Xj = the radiological decay constant for radionuclide i, sec 1 ;>
t = the exposure time, sec; 8
= 4.73 X 10 sec (5 years)'
DFGi = the ground plant dose conversion factor for radionuclide i; mrem/hr per pCi/m SF = the shielding factor (dimensionless)
Ii = factor to account for fractional deposition of radionuclide i.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE "MW ~~~~~~~~~~~~~~NUMBER:
OFFSITE DOSE CALCULATION: H4 1~~~~1 ~~MANUAL (ODCM) REV: 17 Page 212 of 221 For radionuclides other than iodine, the factor li is equal to one. For radioiodines, the value of II may vary. However, a value of 1.0 was used in calculating the R values in Table 5.5-1.
A shielding factor of 0.7 from Table E-1 5 of Regulatory Guide 1.109 Revision is used.
A tabulation of DFGI values is presented in Table E-6 of Regulatory Guide 1.109 Revision 1.
C.2.3 Grass-Cow or Goat-Milk Pathway RIM = 11K'QF Uap Fm (DFLi)a exitffpfs r( Eitep) + B rv(I-eXib) 1 +
(1 fpfs) r_l_ e___E_tes Er(1-e +
Bi (l -e - i ) .t j1-hj -Ektes) (C.2-3) where:
RiM dose factor for the cow milk or goat milk pathway, for each identified radionuclide i for the organ of interest, m2 _mrey/yr per pCi/sec; K' = a constant of unit conversion;
= 106 pCi4iCi; QF = the cow's or goat's feed consumption rate, kg/day (wet weight);
Uap = the receptor's milk consumption rate for age group a, liters/yr; Yp = the agricultural productivity by unit area of pasture feed grass, kg/M 2 ;
YS = the agricultural productivity by unit areas of stored feed, kg/m; Fm = the stable element transfer coefficients, pCi/liter per pCI/day; r =
- fraction of deposited activity retained on cow's feed grass;
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 F2SA .Page 213 of 221 (DFLi)a = the organ ingestion dose factor for radionuclide I for the receptor in age group a, mrem/pCI; XE = Xi + Xw; Xi = the readiological decay constant for radionuclide 1,
-1 sec xw = the decay constant for removal of activity on leaf and plant surfaces by weathering, sec 1
= 5.73 X 10 sec (corresponding to a 14 day half-lift);
tf = the transport time from feed to cow or goat to milk to receptor, sec; th = the transport time from harvest, to cow or goat, to consumption, sec; tb = period of time that activity builds up in soil, sec; Biv concentration factor for uptake of radionuclide i from the soil by the edible parts of crops, pCi/kg (wet weight) per PCi/kg (dry soil);
P = effective surface density for soil, (dry weight) kg/M 2 ;
fp = fraction of the year that the cow or goat is on pasture; fs = fraction of the cow feed that is pasture grass while the cow is on pasture; t
ep = period of pasture grass exposure during the growing season, sec; tes = period of crop exposure during the growing season, sec; II = factor to account for fractional deposition of radionuclide i.
For radionuclides other than iodine, the factor I is equal to one. For radioiodines, the value of may vary. However, a value of 1.0 was used in calculating the R values Tables 5.5-8 through 5.5-15.
Milk cattle and goats are considered to be fed from two potential sources, pasture grass and stored feeds. Following the development in Regulatory Guide 1.109 Revision 1, the value of fs was considered unity in lieu of site-specific information. The value of fp was 0.5 based upon a 6-month grazing period.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 214 of 221 Table C-1 contains the appropriate parameter values and their source in Regulatory Guide 1.109 Revision 1.
The concentration of tritium in milk is based on the airborne concentration rather than the deposition. Therefore, the RI is based on X/Q:
RTM = K'K"' FmQFUap(DFLi)a 0.75 (0.5/H) (C.24) where:
RTM = dose factor for the cow or goat milk pathway for tritium for the organ of interest, mrem/yr per OCi/m 3 ;
K"' = a constant of unit conversion;
= 103 gm/kg; H = absolute humidity of the atmosphere, gm/m3 0.75 = the fraction of total feed that is water; 0.5 = the ratio of the specific activity of the feed grass to the atmospheric water.
and other parameters and values are given below. A value of H of 8 grams/meter 3 , was used in lieu of site-specific information.
C.2.4 Grass-Cow-Meat Pathway The integrated concentration in meat follows in a similar manner to the development for the milk pathway, therefore:
RB= Ii K'QF Uap Ff (DFLi)aexiS rle Eyt ep) + B v(1 1 - let ]
(1- fpff)r( + B1 (1-e ) e -Xith (C.2-5)
PSL YSX Ei + J
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 215 of 221 where:
RiB dose factor for the meat ingestion pathway for radionuclide i for any organ of interst, m2 mrem/yr per EICi/sec; Ff = the stable element transfer coefficients, pCi/Kg per pCi/day; Uap = the receptor's meat consumption rate for age group a, kg/yr; ts = the transport time from slaughter to consumption, sec; th = the transport time from harvest to animal consumption, sec; tep = period of pasture grass exposure during the growing season, sec; tes period of crop exposure during the growing season, sec; Ij = factor to account for fractional desposition of radionuclide i.
For radionuclides other than iodine, the factor I is equal to one. For radioiodines, the value of I may vary. However, a value of 1.0 was used in calculating the R values in Tables 5.5-5 through 5.5-7.
All other terms remain the same as defined in Equation C.2-3. Table C-2 contains the values which were used in calculating R for the meat pathway.
The concentration of tritium in meat is based on its airborne concentration rather than the deposition. Therefore, the RI is based on X/Q.
RTB = K'K" ' FfQFUap(DFLI)a 0.75 (0.5/H) (C.2-6) where:
RTB = dose factor for the meat ingestion pathway for tritium for any organ of interest, mrem/yr per ,Ci/rM3 .
All other terms are defined in Equation C.2-4 and C.2-5, above.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT .HPROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 F SI. .Page 216 of 221 C.2.5 Vegetation Pathway The integrated concentration in vegetation consumed by man follows the expression developed in the derivation of the milk factor. Man is considered to consume two types of vegetation (fresh and stored) that differ only in the time period between harvest and consumption, therefore:
Biv(1 e-Xib ) 1 Ri = K'(DFLi)a PAi (U Sfge Xi'h where:
Fr(1-L e-7Eite)
YV XEi B1v (- e-i'b)
PA 1
J I (C.2-7)
RTv = dose factor for vegetable pathway for radionuclide i for organ of interest, m2 _mrem/yr per [iCi/sec; K' = a constant of unit conversion;
= 106 pCi/pCi; L
Ua = the consumption rate of fresh leafy vegetation by the receptor in age group a, kg/yr; us a = the consumption the or stored vegetation by the receptor in age group a, kg/yr; fL = the fraction of the annual intake of fresh leafy vegetation grown locally; fg = the fraction of the annual intake of stored vegetation grown locally; tL = the average time between harvest of leafy vegetation and its consumption, sec; th = the average time between harvest of stored vegetation and its consumption, sec;
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE YV = the vegetation areal density, kg/m2; te = period of leafy vegetable exposure during growing season, sec; Ii = factor to account for fractional deposition of radionuclide i.
For radionuclides other than iodine, the factor lI is equal to one. For radioiodines, the value of Ij may vary. However, a value of 1.0 was used in calculating the R values in tables 5.5-2 through 5.5-4.
All other factors were defined above.
Table C-3 presents the appropriate parameter values and their source in Regulatory Guide 1.109 Revision 1.
In lieu of site-specific data default values for fL and fg, 1.0 and 0.76, respectively were used in the calculation of Ri. These values were obtained from Table E-15 of Regulatory Guide 1.109 Revision 1.
The concentration of tritium in vegetation is based on the airborne concentration rather than the deposition. Therefore, the R1 is based on X/Q:
RTV = K'K"' [U fL + Uafg] (DFLI)a 0.75 (0.5/H) (C.2-8) where:
RTV = dose factor for the vegetable pathway for tritium for any organ of interest, m2 _mrem/yr per Ci/m3 .
All other terms remain'the same as those in Equations C.2-4 and C.2-7.
PRAIRIE ISLAND NUCLEAR GENERATING PLANT -- H PROCEDURE Table C-1 - Parameters for Cow and Goat Milk Pathways Parameter Value Reference (Req. Guide 1.109 Rev. 1)
QF (kg/day) 50 (cow) Table E-3 6 (goat) Table E-3 Yp (kg/m 2 ) 0.7 Table E-15
- 5 Table E-15 tf (seconds) 1.73 x 10 (2 days) r 1.0 (radioiodines) Table E-15 0.2 (particulates) Table E-15 (DFLi)a- (mrem/pCi) Each radionuclide Tables E-11 to E-14 Fm (pCi/day per pCi/liter) Each stable element Table E-1 (cow)
Table E-2 (goat) tb (seconds), 4.73x10 (15yr) Table E-15 yS (kg/m 2) 2.0 Table E-15 Yp (kg/m 2 ) 0.7 Table E-15 th (seconds) 7.78 x 106 (90 days) Table E-15 Uap (liters/yr) 330 infant Table E-5 330 child Table E-5 400 teen Table E-5 310 adult Table E-5 6
tep (seconds) 2.59 x 10 (30 days) Table E-15 tes (seconds) 5.18 x 10 (60 days) Table E-15 Biv (pCi/Kg (wet weight) Each stable element Table E-1 per pCi/Kg (dry soil))
P (Kg/m (dry weight)) 240 Table E-15
PRAIRIE ISLAND NUCLEAR GENERATING PLANT HPROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17 Page 219 of 221 Table C-2 Parameters for the Meat Pathway Parameter Value Reference (Req. Guide 1.109 Rev. 1) r 1.0 (radioiodines) Table E-15 0.2 (particulates) Table E-15 Ff (pCi/Kg per pCi/day' Each stable element Table E-1 Uap (Kgfyr) 0 infant Table E-5 41 child Table E-5 65 teen Table E-5 110 adult.X Table E-5 (DFLi)a (mrem/pCi) Each radionuclide Tables E-1 1 to E-14 Yp (kg/m ) 0.7 Table E-15 Ys (kg/m ) 2.0 Table E-15 tb (seconds) 4.73 x 10 (15 yr) Table E-15 ts (seconds) 1.73 x 106 (20 days) Table E-15 th (seconds) 7.78 x 10 (90 days) Table E-15 tep (seconds) 2.59 x 10 (30 days) Table E-15 tes (seconds) 5.18 x 10 (60 days) Table E-15 Qf (kg/day) 50 Table E-3 B1v (pCi/Kg (wet weight )? Each stable element Table E-1 per pCi/Kg (dry soil)
P (Kg/m (dry weight)) 240 Table E-15
PRAIRIE ISLAND NUCLEAR GENERATING PLANT . I; . . . H PROCEDURE NUMBER:
OFFSITE DOSE CALCULATION H4 MANUAL (ODCM) REV: 17
_ _ _ __ .Page 220 of 221 THIS PAGE IS LEFT INTENTIONALLY BLANK
PRAIRIE ISLAND NUCLEAR GENERATING PLANT H PROCEDURE Table C Parameters for the Vegetable Pathway Parameter Value Reference (Req. Guide 1.109 Rev. 1) r (dimensionless) 1.0 (radioiodines) Table E-1 0.2 (particulates) Table E-1 (DFLi)a (mrem/pCi) Each radionuclide Tables E-1 1 to E-14 Ua (kg/yr) - Infant 0 Table E-5
- Child 26 Table E-5
- Teen 42 Table E-5
- Adult 64 Table E-5 Ua (kg/yr) - Infant 0 Table E-5
- Child 520 Table E-5
- Teen 630 Table E-5
- Adult 520 Table E-5 4 Table E-15 tL (seconds) 8.6 x 10 (1 day) th (seconds) 5.18 x 10 (60 days) Table E-15 Yv (kg/mi2 ) 2.0 Table E-15 te (seconds) 5.18 x 106 (60 days) Table E-15 tb (seconds) 4.73 x 108 (15 yr) Table E-15 P(Kg/m (dry weight)) 240 Table E-15 Biv (pCi/Kg (wet weight) Each stable element Table E-1 per pCi/kg (dry soil))