MONTHYEARML24016A2622023-10-25025 October 2023 Subsequent License Renewal Updated List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected Project L-2023-037, Annual Radioactive Effluent Release Report2023-03-0101 March 2023 Annual Radioactive Effluent Release Report L-2022-076, Subsequent License Renewal Application - Appendix E Environmental Report Supplement 22022-06-0909 June 2022 Subsequent License Renewal Application - Appendix E Environmental Report Supplement 2 L-2022-070, 2021 Annual Radiological Environmental Operating Report2022-05-0303 May 2022 2021 Annual Radiological Environmental Operating Report L-2022-031, Annual Radioactive Effluent Release Report2022-03-0101 March 2022 Annual Radioactive Effluent Release Report L-2021-243, Errata Corrections to FPL Letter L-2021-043 Re 2020 Annual Radioactive Effluent Release Report2021-12-16016 December 2021 Errata Corrections to FPL Letter L-2021-043 Re 2020 Annual Radioactive Effluent Release Report L-2021-099, 2020 Annual Radiological Environmental Operating Report2021-05-10010 May 2021 2020 Annual Radiological Environmental Operating Report L-2021-043, 2020 Annual Radioactive Effluent Release Report, January 2020 Through December 20202021-02-23023 February 2021 2020 Annual Radioactive Effluent Release Report, January 2020 Through December 2020 L-2020-079, 2019 Annual Radiological Environmental Operating Report for Turkey Point Units 32020-05-0707 May 2020 2019 Annual Radiological Environmental Operating Report for Turkey Point Units 3 L-2020-032, 2019 Annual Radioactive Effluent Release Report2020-02-27027 February 2020 2019 Annual Radioactive Effluent Release Report ML19221B5832019-07-25025 July 2019 Biological Opinion for Turkey Point Nuclear Plant Units 3 and 4 License Renewal ML19206B3492019-06-18018 June 2019 Required Turkey Point Annual Monitoring Data 3 - tn_1999_2018_022819 ML19151A7292019-05-31031 May 2019 Public Comment from Laura Reynolds on the Dseis for the Turkey Point SLRA L-2019-017, Submittal of 2018 Annual Radioactive Effluent Release Report2019-02-27027 February 2019 Submittal of 2018 Annual Radioactive Effluent Release Report L-2019-020, Subsequent License Renewal Application Environmental Report Environmental Authorizations Updated Information2019-01-23023 January 2019 Subsequent License Renewal Application Environmental Report Environmental Authorizations Updated Information ML18227A9572018-08-15015 August 2018 Submit Environmental Monitoring Report No. 10, January 1, 1977 Through December 31, 1977 ML18227A9612018-08-15015 August 2018 Submit Semiannual Environmental Report No. 7, January 1, 1976 Through June 30, 1976 ML18187A0302018-07-23023 July 2018 Cooling Tower Retrofit Is Feasible and Cost-Effective L-2018-054, Turkey Point, Units 3 and 4 - 2017 Annual Radioactive Effluent Release Report2018-02-16016 February 2018 Turkey Point, Units 3 and 4 - 2017 Annual Radioactive Effluent Release Report ML18066A5622018-02-16016 February 2018 2017 Annual Radioactive Effluent Release Report L-2017-083, Submittal of 2016 Annual Radiological Environmental Operating Report2017-05-11011 May 2017 Submittal of 2016 Annual Radiological Environmental Operating Report L-2017-029, Submittal of 2016 Annual Radioactive Effluent Release Report2017-02-28028 February 2017 Submittal of 2016 Annual Radioactive Effluent Release Report L-2017-028, Submittal of Special Report of Containment Tendon Corrosion Protection Medium Volume Reduction2017-02-22022 February 2017 Submittal of Special Report of Containment Tendon Corrosion Protection Medium Volume Reduction L-2016-106, Annual Radiological Environmental Operating Report for 20152016-05-12012 May 2016 Annual Radiological Environmental Operating Report for 2015 ML18187A0262016-03-22022 March 2016 FPL Faces Lawsuit Over Leaky Nuclear Cooling Canals at Turkey Point L-2016-029, Submittal of Radioactive Effluent Release Report for 20152016-02-26026 February 2016 Submittal of Radioactive Effluent Release Report for 2015 L-2015-102, Transmittal of 2014 Annual Radiological Environmental Operating Report2015-05-11011 May 2015 Transmittal of 2014 Annual Radiological Environmental Operating Report L-2015-038, 2014 Annual Radioactive Effluent Release Report for the Period January 1, 2014 Through December 31, 20142015-02-25025 February 2015 2014 Annual Radioactive Effluent Release Report for the Period January 1, 2014 Through December 31, 2014 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 10 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 10 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 13 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 13 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 9 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 9 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 8 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 8 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 7 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 7 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 6 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 6 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 5 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 5 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 4 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 4 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 3 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 3 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 2 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 2 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 1 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 1 of 18 ML15364A4222014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 5 of 18 ML15364A4202014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 3 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 11 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 11 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 12 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 12 of 18 ML15364A4232014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 6 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 14 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 14 of 18 ML15364A4182014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 1 of 18 ML15364A4212014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 4 of 18 L-2015-299, Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 17 of 182014-08-31031 August 2014 Turkey Point, Units 3 and 4 - Annual Post-Uprate Monitoring Report for Uprate Project. Part 17 of 18 ML15364A4372014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 18 of 18 ML15364A4342014-08-31031 August 2014 Annual Post-Uprate Monitoring Report for Uprate Project. Part 16 of 18 2023-03-01
[Table view] Category:Letter type:L
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-007, Inservice Inspection Program Owner'S Activity Report (OAR-1)2024-01-18018 January 2024 Inservice Inspection Program Owner'S Activity Report (OAR-1) L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-166, Turkey Points Units 3 and 4, Correction to the 2022 Annual Radioactive Effluent Release Report2023-12-0606 December 2023 Turkey Points Units 3 and 4, Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-172, Supplement to Exemption Request Regarding Enhanced Weapons. Firearms Background Checks. and Security Event Notifications Final Rule2023-11-29029 November 2023 Supplement to Exemption Request Regarding Enhanced Weapons. Firearms Background Checks. and Security Event Notifications Final Rule L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-146, Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule L-2023-078, License Amendment Request 278, Incorporate Advanced Fuel Products, Extend Surveillance Intervals and 10 CFR 50.46 Exemption Request to Facilitate Transition to 24-Month Fuel Cycles2023-11-15015 November 2023 License Amendment Request 278, Incorporate Advanced Fuel Products, Extend Surveillance Intervals and 10 CFR 50.46 Exemption Request to Facilitate Transition to 24-Month Fuel Cycles L-2023-077, License Amendment Request 277 Updated Spent Fuel Pool Criticality Analysis2023-10-11011 October 2023 License Amendment Request 277 Updated Spent Fuel Pool Criticality Analysis L-2023-110, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-08-25025 August 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-115, Inservice Inspection Program Owner'S Activity Report (OAR-1)2023-08-21021 August 2023 Inservice Inspection Program Owner'S Activity Report (OAR-1) L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-094, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-07-27027 July 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-086, Request Temporary Suspension of Turkey Point License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation.2023-06-28028 June 2023 Request Temporary Suspension of Turkey Point License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation. L-2023-074, Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update2023-06-0202 June 2023 Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update L-2023-069, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-05-31031 May 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-072, Preparation and Scheduling of Operator Licensing Examinations2023-05-22022 May 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-071, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal2023-05-22022 May 2023 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal L-2023-061, 2022 Annual Radiological Environmental Operating Report2023-05-12012 May 2023 2022 Annual Radiological Environmental Operating Report L-2023-062, Cycle 33 Core Operating Limits Report2023-04-27027 April 2023 Cycle 33 Core Operating Limits Report L-2023-060, Radiological Emergency Plan, Revision 752023-04-26026 April 2023 Radiological Emergency Plan, Revision 75 L-2023-054, Submittal of Periodic Reports2023-04-12012 April 2023 Submittal of Periodic Reports L-2023-049, Correction to U4R33 Steam Generator Tube Inspection Report2023-03-30030 March 2023 Correction to U4R33 Steam Generator Tube Inspection Report L-2023-021, Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-03-28028 March 2023 Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2023-025, Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-12023-03-15015 March 2023 Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-1 L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-040, Response to Requests for Additional Information (Rals) and Requests for Confirmation of Information (Rc Ls) Following Regulatory Audit of Subsequent License Renewal Application2023-03-0303 March 2023 Response to Requests for Additional Information (Rals) and Requests for Confirmation of Information (Rc Ls) Following Regulatory Audit of Subsequent License Renewal Application L-2023-037, Annual Radioactive Effluent Release Report2023-03-0101 March 2023 Annual Radioactive Effluent Release Report L-2023-017, Radiological Emergency Plan Revision 73 and Revision 7 42023-02-17017 February 2023 Radiological Emergency Plan Revision 73 and Revision 7 4 L-2023-010, Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of RPS / ESFAS / Nis2023-02-10010 February 2023 Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of RPS / ESFAS / Nis L-2023-004, Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of Huma Factors Results2023-01-17017 January 2023 Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement Project - Submittal of Huma Factors Results L-2022-185, Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-12-0909 December 2022 Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-181, Response to Request for Additional Information Regarding License Amendment Request for the Technical Specifications Conversion to NUREG-1431, Revision 52022-12-0101 December 2022 Response to Request for Additional Information Regarding License Amendment Request for the Technical Specifications Conversion to NUREG-1431, Revision 5 L-2022-182, Emergency Response Data System (Eros) Changes2022-11-17017 November 2022 Emergency Response Data System (Eros) Changes L-2022-180, CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2022-11-0909 November 2022 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2022-168, and Point Beach Units 1 and 2 - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report2022-10-26026 October 2022 and Point Beach Units 1 and 2 - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report L-2022-171, 10 CFR 50.59(d)(2) Summary Report2022-10-20020 October 2022 10 CFR 50.59(d)(2) Summary Report L-2022-167, Submittal of Periodic Reports2022-10-13013 October 2022 Submittal of Periodic Reports L-2022-166, Response to Request for Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement2022-10-0505 October 2022 Response to Request for Supplemental Information Regarding License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation System Replacement L-2022-149, U4R33 Steam Generator Tube Inspection Report2022-10-0404 October 2022 U4R33 Steam Generator Tube Inspection Report L-2022-160, Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-10-0404 October 2022 Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-148, Florida Power & Light Company, Comments on NRC Inspection Procedure (IP) 71111.21 N.03, Commercial Grade Dedication2022-09-16016 September 2022 Florida Power & Light Company, Comments on NRC Inspection Procedure (IP) 71111.21 N.03, Commercial Grade Dedication L-2022-151, Evacuation Time Estimate Study2022-09-15015 September 2022 Evacuation Time Estimate Study L-2022-142, Revised Diversity and Defense-In-Depth Evaluation (D3), Framatome Document No. 51-9324096-0042022-08-19019 August 2022 Revised Diversity and Defense-In-Depth Evaluation (D3), Framatome Document No. 51-9324096-004 L-2022-136, Response to Request for Additional Information Regarding Turkey Point Unit 3 Cycle 32 Steam Generator Tube Inspection Report2022-08-12012 August 2022 Response to Request for Additional Information Regarding Turkey Point Unit 3 Cycle 32 Steam Generator Tube Inspection Report L-2022-109, Inservice Inspection Program - Owner'S Activity Report (OAR-1)2022-06-27027 June 2022 Inservice Inspection Program - Owner'S Activity Report (OAR-1) L-2022-076, Subsequent License Renewal Application - Appendix E Environmental Report Supplement 22022-06-0909 June 2022 Subsequent License Renewal Application - Appendix E Environmental Report Supplement 2 2024-01-25
[Table view] |
Text
SEP 2 6 2003 FPL L-2003-238 10 CFR 50.36b U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 Editorial Corrections to the 2002 Annual Radiological Environmental Operating Report Florida Power and Light's (FPL) letter L-2003-112 submitted the 2002 Annual Radiological Environmental Operating Report for Turkey Point Units 3 and 4 on May 8, 2003, as required by the Technical Specification 6.9.1.3.
Subsequent review of the report discovered the need for minor editorial corrections. These corrections are described in the Enclosure with mark-up and clean pages included. These pages are replacement pages to the FPL letter submittal L-2003-112 dated May 8, 2003.
Should there be any questions, please contact Walter Parker at 246-6632.
Sincerely, Terry Os Vice President Turkey Point Plant SM Enclosure NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC.
T5i~2 an FPL Group company
Enclosure to L-2003-238 SUMMMARY OF EDITORIAL CORRECTIONS to L-2003-112
- TABLE 1, Page 6 of 8: The correct value for isotope 40K "Control Locations Mean (f0 Range" is 3068(212) instead of 3608(2/2).
- TABLE 1, Page 7 of 8: The correct value for isotope 4K "All Indicator Locations Mean (f)
Range" is 3722(24/24) instead of 722(24/24).
- TABLE IA, Pages 1 of 2 and 2 of 2: The year of the indicated "Dates" for each Pathway for sections A through D is 02 instead of 03.
- ATTACHMENT A, KEY TO SAMPLE LOCATIONS: Distant REMP Sampling Location:
This Map was changed to indicate the correct PTN location and to show locations NNE-22, and WSW-8.
- ATTACHMENT A, KEY TO SAMPLE LOCATIONS: The address for Natoma Substation is added in Page 1 of 4.
Enclosure to L-2003-238 Markup Pages
TABLE I Page 6 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL
SUMMARY
Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade. Florida , Reporting Period January 1 - December 31. 2002 (County, State)
PATHWAY: INGESTION SAMPLES COLLECTED: FISH UNITS: pC/kg, WET Location with Highest Annual Mean Name0 Mean (f)b Type and Total Number Lower Limit of All Indicator Distance & Range Control Locations-of Analyses Performed Detectiona (LLD) Locations Direction Mean (f)b Range Mean (f) Range Gamma Isotopic, 4
'Be <MDA <MDA 40K 130 2736 (2/2) T-81 2736 (2/2) 3683068 (2/2) 2263 - 3208 6 mi., S 2263 - 3208 2716 - 3421 54Mn 9 <MDA <MDA 59Fe 16 <MDA <MDA 8Co 9 <MDA <MDA 64 Co 10 <MDA <MDA 6Zn 17 <MDA <MDA 9 <MDA <MDA 137CS 9 <MDA <MDA "2Ra 20 < MDA) <MDA Number of Non-routine Reported Measurements = 0
TABLE 1 Page 7 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL
SUMMARY
Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade. Florida , Reporting Period January 1 - December 31. 2002 (County, State)
PATHWAY: INGESTION SAMPLES COLLECTED: BROAD LEAF VEGETATION UNITS: pCi/kg, WET Location with Highest Annual Mean Namec Mean (f)b Type and Total Number Lower Limit of All Indicator Distance & Range Control Locations of Analyses Performed Detectiona (LLD) Locations Direction Mean (f)b Range Mean (f) Range Gamma Isotopic, 36 7Be 71 1498 (24/24) T-40 1572 (12/12) 1306 (12/12) 596 - 3233 3mi.,W 596 - 3233 490- 1851 100 3722 (24/24) T-41 4531 (12/12) 4179 (12/12) I 1745 - 7035 2 mi., W/NW 2669 - 7035 2291 - 5922 58co 9 <MDA <MDA 10 <MDA <MDA 1311 9 <MDA <MDA 134Cs 8 <MDA <MDA 137cs 8 78 (23/24) T-41 78 (11/12) 46 (1/12) 22 - 208 2 mi., W/NW 22 - 208 210Pb 579 (3124) T-40 683 (1/12) 545 (1/12) 296 - 749 3mi.,W 200 (1/24) T-40 200 (1/12) <MDA 3 mi., W Number of Non routine Reported Measurements = 0
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT- UNITS 3 & 4 TABLE 1A (Page 1 of 2)
DEVIATIONS / MISSING DATA A) Pathway: Airborne, Radioiodines & Particulates Location: T-57, 4 miles NorthWest Dates: 02/05/03-2 to 02/14/0302 Deviation: Failure to provide continuous monitoring.
Description of Vacuum hose found disconnected from air sampling system; Problem: unknown cause.
Corrective Reconnected hose, ensured good fit; checked connections at Action: other air sampling locations.
B) Pathway: Airborne, Radioiodines & Particulates Location: T-51, 2 miles, NorthNorthWest Dates: 05106/032 to 05/13/0302 Deviation: Failure to provide continuous monitoring.
Description of Partial sample collected; sampling station damaged by gunfire Problem:
Corrective Repaired sampling station 'hut'; replaced sampling station Action: equipment, ensured equipment operating correctly.
C) Pathway: Airborne, Radioiodines & Particulates Location: T-72, < 1 mile WestSouthWest Dates: 06/03/002 to 06/12/0302 Deviation: Failure to provide continuous monitoring.
Description of Partial sample collected; suspect power interruptions during Problem: sampling period.
Corrective Ensured equipment operating correctly.
Action:
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 1A (Page 2 of 2)
DEVIATIONS I MISSING DATA D) Pathway: Airborne, Radioiodines & Particulates Location: T-72, < 1 mile WestSouthWest Dates: 08/2810302 to 09/1203-02 , two sampling periods I Deviation: Failure to provide continuous monitoring.
Description of Power was unavailable during the end of the first sampling period Problem: and beginning of second sampling period; cause was construction activities and temporary shutdown of power.
Corrective Ensured equipment operating correctly.
Action:
E) Pathway: Direct Exposure Location: WSW-8, 8 miles WestSouthWest Dates: Fourth calendar quarter Deviation: Failure to provide continuous monitoring.
Description of TLDs missing when collection was attempted.
Problem:
Corrective Replaced missing TLD.
Action:
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4
'A SP, DISTANT REMP SAMPLING LOCATIONS I-out. Pe.....
... * '~ utlis~rt T 67 * ::I .. ......
NW-1 - .O ..
. $1... ;.
NL X
- :/.:
f 4~~~
- ........Escei~ynte~..y
~~
.'....; 1'-
- N : - ...M7.:: -: ::: v~~~~~~..:.::.:::.:.. :-.
- ~~~~~.. . ... ... .. . t ;.'... ... , .@@*': ' i..0 w'.
- 3::......... ... ......................:::::::g:
e.:.:
N-7
".' .' - : . .. '.- ': . -: : ->-to~eaTEg
~omeead A 5; .j,'
- iW~t1 :X-: ... ::[-::!.: :,
- -ja :....:
' W.S ,$: T;.J f~~~..S' ... W-9
~~~~~~~~~~' ::N.. '. . .
. .'"~.. '"'... . .'. ..... ,-'
- ~~~~~~~~~~~~~~~~~~~~~~~~~~.. £:....... ...;re>u,:,,:...,.,-:
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT A PAGE 1 OF 4 PATHWAY: DIRECT RADIATION SAMPLES COLLECTED: TLD SAMPLE COLLECTION FREQUENCY: QUARTERLY Location (a)
Name Description N-2 Convey Point, Parking Area N-7 Black Point Marina Parking Lot N-10 Old Cutler Rd. approx. 196th Street NNW-2 East End North Canal Road NNW-10 Bailes Road & U.S. #1 NW-1 Turkey Point Entrance Road NW-5 Mowry Drive & 117th Avenue NW-10 Newton Road, North of Coconut Palm Drive WNW-10 Homestead Middle School W-1 On-Site, North Side of Discharge Canal W-5 Palm Drive & Tallahassee Road W-9 Card Sound Road, 0.6 mile from U.S. #1 WSW-8 Card Sound Road, 3.4 miles from U.S. #1 SW-1 On-Site near Land Utilization Offices SW-8 Card Sound Road, 5 miles from U.S. #1 SSW-5 On-Site, Southwest Corner of Cooling Canals SSW-i0 Card Sound Road, west side of Toll Plaza S-5 On-Site, South East Comer of Cooling Canals S-10 Card Sound Road at Steamboat Creek SSE-1 Turtle Point SSE-10 Ocean Reef Control NNE-22 Natoma Substation 2475 SW 16 Ct "The location name is the direction sector - approximate distance (miles)
Enclosure to L-2003-238 Replacement Clean Pages
TABLE 1 Page 6 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL
SUMMARY
Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade. Florida , Reporting Period Januarv 1 - December 31. 2002 (County, State)
PATHWAY: INGESTION SAMPLES COLLECTED: FISH UNITS: pCVkg, WET Location with Highest Annual Mean Namec Mean (f)b Type and Total Number Lower Limit of All Indicator Distance & Range Control Locations of Analyses Performed Detectiona (LLD) Locations Direction Mean (f)b Range Mean (f) Range Gamma Isotopic, 4
<MDA <MDA 130 2736(2/2) T-81 2736 (2/2) 3068 (2/2) 2263 - 3208 6 mi., S 2263 - 3208 2716 - 3421 54Mn 9 <MDA <MDA 59Fe 16 <MDA <MDA 58c.o 9 <MDA <MDA 10 <MDA <MDA 6Zn 17 <MDA <MDA 9 <MDA <MDA 9 <MDA <MDA 20 < MDA) <MDA Number of Non-routine Reported Measurements = 0
TABLE 1 Page 7 of 8 ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM ANNUAL
SUMMARY
Name of Facility Turkey Point Units 3 & 4, Docket No(s). 50-250 & 50-251 Location of Facility Miami-Dade. Florida , Reporting Period January 1 - December 31. 2002 (County, State)
PATHWAY: INGESTION SAMPLES COLLECTED: BROAD LEAF VEGETATION UNITS: DCVka. WET Location with Highest Annual Mean Name' Mean (f)b Type and Total Number Lower Limit of All Indicator Distance & Range Control Locations of Analyses Performed Detectiona (LLD) Locations Direction Mean (fib Range Mean (f) Range Gamma Isotopic, 36 7 Be 71 T-40 1498 (24/24) 1572 (12112) 1306 (12/12) 596 - 3233 3mi.,W 596 - 3233 490- 1851 100 3722 (24/24) T-41 4531 (12/12) 4179 (12/12) 1745 - 7035 2 mi., W/NW 2669 - 7035 2291 - 5922 58CO 9 <MDA <MDA 60CO 10 <MDA <MDA 131i 9 <MDA <MDA 134'CS 8 <MDA <MDA 8 78 (23124) T-41 78 (11/12) 46 (1/12) 22 - 208 2 mi., W/NW 22 - 208 579 (3124) T-40 683 (1/12) 545 (1/12) 296 - 749 3mi.,W mRa 200 (1/24) T-40 200 (1/12) <MDA 3mi.,W Number of Non routine Reported Measurements = 0
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT- UNITS 3 & 4 TABLE 1A (Page 1 of 2)
DEVIATIONS / MISSING DATA A) Pathway: Airborne, Radioiodines & Particulates Location: T-57, 4 miles NorthWest Dates: 02/05/02 to 02/14/02 Deviation: Failure to provide continuous monitoring.
Description of Vacuum hose found disconnected from air sampling system; Problem: unknown cause.
Corrective Reconnected hose, ensured good fit; checked connections at Action: other air sampling locations.
B) Pathway: Airborne, Radiolodines & Particulates Location: T-51, 2 miles, NorthNorthWest Dates: 05/06/02 to 05/13/02 Deviation: Failure to provide continuous monitoring.
Description of Partial sample collected; sampling station damaged by gunfire Problem:
Corrective Repaired sampling station 'hut'; replaced sampling station Action: equipment, ensured equipment operating correctly.
C) Pathway: Airborne, Radioiodines & Particulates Location: T-72, < 1 mile WestSouthWest Dates: 06/03/02 to 06/12/02 Deviation: Failure to provide continuous monitoring.
Description of Partial sample collected; suspect power interruptions during Problem: sampling period.
Corrective Ensured equipment operating correctly.
Action:
- 2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 TABLE 1A (Page 2 of 2)
DEVIATIONS / MISSING DATA D) Pathway: Airborne, Radioiodines & Particulates Location: T-72, < 1 mile WestSouthWest Dates: 08/28/02 to 09/12/02, two sampling periods Deviation: Failure to provide continuous monitoring.
Description of Power was unavailable during the end of the first sampling period Problem: and beginning of second sampling period; cause was construction activities and temporary shutdown of power.
Corrective Ensured equipment operating correctly.
Action:
E) Pathway Direct Exposure Location: WSW-8, 8 miles WestSouthWest Dates: Fourth calendar quarter Deviation: Failure to provide continuous monitoring.
Description of TLDs missing when collection was attempted.
Problem:
Corrective Replaced missing TLD.
Action:
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 DISTANT REMP SAMPLING LOCATIONS
~~P~~n~~%¶~~'NNE-22
_- y # l . .1 s ~~~.;.s,,R-!,...
.e............ ,,, , ... ;..
S0~ - m~~t ff} Nt ; .t4sw M1 ---. yX/5 J: 1~~~~~~~~. ........ ..s,.Xij. .;eii
.... ...... I...............
Old K~~~ey f - - 0 K T 5} M . ,40 i i el w~~~~~~~~. ..-.. ..........
t.
- - WX : :4: - -- s PTN s si :^^ ~~~~~~~..........
........... r s' i
- - s - - tl : t ; L ? S /~~~~~~~~ ........ o. .;,.>s
>.2
2002 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT TURKEY POINT PLANT - UNITS 3 & 4 ATTACHMENT A PAGE 1 OF 4 PATHWAY: DIRECT RADIATION SAMPLES COLLECTED: TLD SAMPLE COLLECTION FREQUENCY: QUARTERLY Location (a)
Name Description N-2 Convey Point, Parking Area N-7 Black Point Marina Parking Lot N-10 Old Cutler Rd. approx. 196th Street NNW-2 East End North Canal Road NNW-10 Bailes Road & U.S. #1 NW-1 Turkey Point Entrance Road NW-5 Mowry Drive & 11 7th Avenue NW-10 Newton Road, North of Coconut Palm Drive WNW-10 Homestead Middle School W-1 On-Site, North Side of Discharge Canal W-5 Palm Drive & Tallahassee Road W-9 Card Sound Road, 0.6 mile from U.S. #1 WSW-8 Card Sound Road, 3.4 miles from U.S. #1 SW-1 On-Site near Land Utilization Offices SW-B Card Sound Road, 5 miles from U.S. #1 SSW-5 On-Site, Southwest Corner of Cooling Canals SSW-l0 Card Sound Road, west side of Toll Plaza S-5 On-Site, South East Comer of Cooling Canals S-10 Card Sound Road at Steamboat Creek SSE-1 Turtle Point SSE-10 Ocean Reef Control NNE-22 Natoma Substation 2475 SW 16 Ct aThe location name is the direction sector - approximate distance (miles)