MONTHYEARL-23-260, Corrections to the 2022 Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station2023-12-0707 December 2023 Corrections to the 2022 Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station L-23-243, Independent Spent Fuel Storage Installation - Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-12-0606 December 2023 Independent Spent Fuel Storage Installation - Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation L-23-215, Changes to Emergency Plan2023-10-19019 October 2023 Changes to Emergency Plan L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-175, Submittal of Fifth Ten Year Inservice Testing Program2023-08-0101 August 2023 Submittal of Fifth Ten Year Inservice Testing Program L-23-034, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-06-13013 June 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-135, Response to Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations2023-05-31031 May 2023 Response to Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-131, Readiness for Resumption of NRC Supplemental Inspection2023-05-12012 May 2023 Readiness for Resumption of NRC Supplemental Inspection L-23-101, Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station - 20222023-05-12012 May 2023 Combined Annual Radiological Environmental Operating Report and Radioactive Effluent Release Report for the Davis-Besse Nuclear Power Station - 2022 L-23-092, Occupational Radiation Exposure Report for Year 20222023-04-27027 April 2023 Occupational Radiation Exposure Report for Year 2022 L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-037, and Perry Nuclear Power Plant - Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2023-03-29029 March 2023 and Perry Nuclear Power Plant - Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-059, Response to Apparent Violation in NRC Inspection Report 05000346/2022091; EA 23-0022023-03-0909 March 2023 Response to Apparent Violation in NRC Inspection Report 05000346/2022091; EA 23-002 L-22-212, CFR 50.55a Request RP-5 Regarding Inservice Pump Testing2023-03-0606 March 2023 CFR 50.55a Request RP-5 Regarding Inservice Pump Testing L-23-048, Response to Request for Additional Information Regarding Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report2023-03-0101 March 2023 Response to Request for Additional Information Regarding Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-253, Submittal of Pressure and Temperature Limits Report, Revision 52023-01-10010 January 2023 Submittal of Pressure and Temperature Limits Report, Revision 5 L-22-284, Request for Notice of Enforcement Discretion for Technical Specification 3.7.9, Ultimate Heat Sink (UHS)2022-12-28028 December 2022 Request for Notice of Enforcement Discretion for Technical Specification 3.7.9, Ultimate Heat Sink (UHS) L-22-211, Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report2022-09-29029 September 2022 Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report L-22-216, Submittal of Pressure and Temperature Limits Report. Revision 42022-09-27027 September 2022 Submittal of Pressure and Temperature Limits Report. Revision 4 L-22-213, Occupational Radiation Exposure Report for Year 2021 - Correction2022-09-23023 September 2022 Occupational Radiation Exposure Report for Year 2021 - Correction L-22-129, Submittal of the Updated Final Safety Analysis Report, Revision 342022-09-20020 September 2022 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-22-194, Submittal of Supplemental Information for the Reanalysis for Protection Against Low Temperature Reactor Coolant System Overpressure Events2022-09-19019 September 2022 Submittal of Supplemental Information for the Reanalysis for Protection Against Low Temperature Reactor Coolant System Overpressure Events L-22-203, Submittal of Evacuation Time Estimates2022-09-12012 September 2022 Submittal of Evacuation Time Estimates L-22-050, Summary of Changes to the Energy Harbor Nuclear Corp. Quality Assurance Program Manual2022-08-0909 August 2022 Summary of Changes to the Energy Harbor Nuclear Corp. Quality Assurance Program Manual L-22-152, Response to Request for Additional Information Regarding a License Amendment Request That Revises the Davis-Besse Nuclear Power Station Emergency Plan2022-07-0505 July 2022 Response to Request for Additional Information Regarding a License Amendment Request That Revises the Davis-Besse Nuclear Power Station Emergency Plan L-22-068, Cycle 22 and Refueling Outage 22 Inservice Inspection Summary Report2022-06-30030 June 2022 Cycle 22 and Refueling Outage 22 Inservice Inspection Summary Report L-22-037, 2021 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2022-06-30030 June 2022 2021 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-22-149, Post Accident Monitoring Report2022-06-23023 June 2022 Post Accident Monitoring Report L-22-153, Readiness for NRC Supplemental Inspection Required for a White Finding2022-06-22022 June 2022 Readiness for NRC Supplemental Inspection Required for a White Finding L-22-098, Withdrawal of Proposed Inservice Inspection Alternative RR-A22022-06-22022 June 2022 Withdrawal of Proposed Inservice Inspection Alternative RR-A2 L-22-136, Steam Generator Tube Circumferential Crack Report - Spring 2022 Refueling Outage2022-06-0707 June 2022 Steam Generator Tube Circumferential Crack Report - Spring 2022 Refueling Outage L-22-102, Report of Facility Changes, Tests, and Experiments2022-05-16016 May 2022 Report of Facility Changes, Tests, and Experiments L-22-092, Combined Annual Radiological Environmental Operating Report and Radiological Effluent Release Report for the Davis-Besse Nuclear Power Station - 20212022-05-16016 May 2022 Combined Annual Radiological Environmental Operating Report and Radiological Effluent Release Report for the Davis-Besse Nuclear Power Station - 2021 L-22-124, Response to Request for Additional Information Regarding License Amendment Request to Revise the Design Basis for the Shield Building2022-05-12012 May 2022 Response to Request for Additional Information Regarding License Amendment Request to Revise the Design Basis for the Shield Building L-22-047, Unit No.1 - Core Operating Limits Report, Cycle 23, Revision O and Revision 12022-05-10010 May 2022 Unit No.1 - Core Operating Limits Report, Cycle 23, Revision O and Revision 1 L-22-127, Readiness for NRC Supplemental Inspection Required for a Greater than Green Finding2022-05-0606 May 2022 Readiness for NRC Supplemental Inspection Required for a Greater than Green Finding L-22-089, Occupational Radiation Exposure Report for Year 20212022-04-12012 April 2022 Occupational Radiation Exposure Report for Year 2021 L-22-056, Energy Harbor Nuclear Corp., Annual Notification of Property Insurance Coverage2022-03-22022 March 2022 Energy Harbor Nuclear Corp., Annual Notification of Property Insurance Coverage L-22-059, Response to Request for Additional Information on Proposed Inservice Test Alternative RP-32022-03-21021 March 2022 Response to Request for Additional Information on Proposed Inservice Test Alternative RP-3 L-22-074, Response to Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations2022-03-15015 March 2022 Response to Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations L-22-061, Ile Post Exam Letter L-22-0612022-02-24024 February 2022 Ile Post Exam Letter L-22-061 L-22-023, Retrospective Premium Guarantee2022-02-17017 February 2022 Retrospective Premium Guarantee L-21-266, Response to Request for Additional Information on Proposed Inservice Inspection Alternative RR-A22022-01-27027 January 2022 Response to Request for Additional Information on Proposed Inservice Inspection Alternative RR-A2 L-20-289, Emergency Plan Amendment Request2022-01-19019 January 2022 Emergency Plan Amendment Request L-21-290, Response to NRC Inspection Report 05000346/2021091, EA-21-1762021-12-21021 December 2021 Response to NRC Inspection Report 05000346/2021091, EA-21-176 2023-09-12
[Table view] Category:Response to Request for Additional Information (RAI)
MONTHYEARL-23-048, Response to Request for Additional Information Regarding Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report2023-03-0101 March 2023 Response to Request for Additional Information Regarding Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report ML22292A0232022-10-18018 October 2022 Framatome Inc., Document ANP-2718-007Q1NP, Revision 0, Response to Request for Additional Information on Appendix G Pressure-Temperature Limits for 52 EFPY for Davis-Besse Nuclear Power Station - First Energy Nuclear Operating Company L-22-229, Response to Request for Additional Information Regarding Request to Withhold Information in Framatome Inc. Document ANP-2718P-007 from Public Disclosure & Affidavit2022-10-13013 October 2022 Response to Request for Additional Information Regarding Request to Withhold Information in Framatome Inc. Document ANP-2718P-007 from Public Disclosure & Affidavit L-22-152, Response to Request for Additional Information Regarding a License Amendment Request That Revises the Davis-Besse Nuclear Power Station Emergency Plan2022-07-0505 July 2022 Response to Request for Additional Information Regarding a License Amendment Request That Revises the Davis-Besse Nuclear Power Station Emergency Plan L-22-124, Response to Request for Additional Information Regarding License Amendment Request to Revise the Design Basis for the Shield Building2022-05-12012 May 2022 Response to Request for Additional Information Regarding License Amendment Request to Revise the Design Basis for the Shield Building L-22-059, Response to Request for Additional Information on Proposed Inservice Test Alternative RP-32022-03-21021 March 2022 Response to Request for Additional Information on Proposed Inservice Test Alternative RP-3 ML22081A1472022-03-11011 March 2022 R22 (March 2022) - Steam Generator Tube Inspection Discussion Points 11 March 2022 ML22049A0662022-02-10010 February 2022 Response to NRC Questions from 2/1/2022 Regulatory Conference on Failed Field Flash Selector Switch L-21-266, Response to Request for Additional Information on Proposed Inservice Inspection Alternative RR-A22022-01-27027 January 2022 Response to Request for Additional Information on Proposed Inservice Inspection Alternative RR-A2 ML21130A2192021-05-10010 May 2021 Request for Additional Information Regarding Steam Generator Tube Inspection Reports (EPIDs L2020-LRO-0055, L-2020-LRO-0082, and L2020-LRO-0083) ML21088A3442021-03-29029 March 2021 Final Supplemental Response to Nuclear Regulatory Commission Generic Letter 2004-02 L-21-101, Final Supplemental Response to Nuclear Regulatory Commission Generic Letter 2004-022021-03-29029 March 2021 Final Supplemental Response to Nuclear Regulatory Commission Generic Letter 2004-02 L-21-030, Response to Request for Additional Information Regarding an Amendment to Incorporate the Applicable Standard Technical Specification 5.2.2, Unit Staff, Into the Facility Technical Specifications (EPID L-20202021-01-27027 January 2021 Response to Request for Additional Information Regarding an Amendment to Incorporate the Applicable Standard Technical Specification 5.2.2, Unit Staff, Into the Facility Technical Specifications (EPID L-2020 L-20-313, Response to Request for Additional Information Regarding Request for Exemption -Part 73 Force-on-Force2020-12-0707 December 2020 Response to Request for Additional Information Regarding Request for Exemption -Part 73 Force-on-Force L-20-183, Response to Request for Additional Information Regarding License Amendment Request for Adoption of TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force2020-06-23023 June 2020 Response to Request for Additional Information Regarding License Amendment Request for Adoption of TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force L-20-155, Response to Request for Additional Information Regarding Request for Exemptions to Certain Periodic Training Requirements for Security Personnel (Epids L-2020-LLE-0026 to -0040)2020-05-0606 May 2020 Response to Request for Additional Information Regarding Request for Exemptions to Certain Periodic Training Requirements for Security Personnel (Epids L-2020-LLE-0026 to -0040) L-20-041, Response to Request for Additional Information Regarding License Amendment Request to Extend Containment Leakage Test Interval2020-02-0303 February 2020 Response to Request for Additional Information Regarding License Amendment Request to Extend Containment Leakage Test Interval L-19-182, Response to RAI Regarding an Application for Order Consenting to Transfer of License2019-08-0202 August 2019 Response to RAI Regarding an Application for Order Consenting to Transfer of License L-19-178, Response to Request for Additional Information Regarding Request for Approval of Decommissioning Quality Assurance Program for the Davis-Besse Nuclear Power Station2019-07-16016 July 2019 Response to Request for Additional Information Regarding Request for Approval of Decommissioning Quality Assurance Program for the Davis-Besse Nuclear Power Station L-19-166, Response to Request for Additional Information and Supplemental Information Regarding License Amendment Request for Proposed Post-Shutdown Emergency Plan2019-07-0808 July 2019 Response to Request for Additional Information and Supplemental Information Regarding License Amendment Request for Proposed Post-Shutdown Emergency Plan L-19-160, Response to Request for Additional Information Regarding License Amendment Request for Permanently Defueled Technical Specifications2019-06-26026 June 2019 Response to Request for Additional Information Regarding License Amendment Request for Permanently Defueled Technical Specifications L-18-121, Response to Request for Supplemental Information Regarding Generic Letter 2016-01 Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools.2018-05-25025 May 2018 Response to Request for Supplemental Information Regarding Generic Letter 2016-01 Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools. L-18-125, Response to Follow-up Request for Additional Information Regarding Exemption Request for a Physical Barrier Requirement IEPID-L-2017-l-LE-0019 (CAC Nos.000976/05000334/-L-2017-LLE-0019 MG0010, 000976/05000334/L-2017-LLE-0019 MG0011,000976/02018-05-0202 May 2018 Response to Follow-up Request for Additional Information Regarding Exemption Request for a Physical Barrier Requirement IEPID-L-2017-l-LE-0019 (CAC Nos.000976/05000334/-L-2017-LLE-0019 MG0010, 000976/05000334/L-2017-LLE-0019 MG0011,000976/0 L-18-085, Response to Request for Additional Information and Supplemental Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 8052018-04-0202 April 2018 Response to Request for Additional Information and Supplemental Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 805 L-18-061, Units. 1 & 2, Davis-Besse, and Perry, Response to Request for Additional Information Regarding Exemption Request for a Physical Barrier Requirement2018-03-16016 March 2018 Units. 1 & 2, Davis-Besse, and Perry, Response to Request for Additional Information Regarding Exemption Request for a Physical Barrier Requirement L-17-372, Response to Request for Additional Information Regarding Request to Use ASME Code Case N-513-4 (EPID 000976/05000334/L-2017-LLR-0088,000976/05000346/L-2017-LLR-0088, 000976/05000412/L-2017-LLR-0088, and 000976/05000440/L-2017-LLR-0088)2017-12-23023 December 2017 Response to Request for Additional Information Regarding Request to Use ASME Code Case N-513-4 (EPID 000976/05000334/L-2017-LLR-0088,000976/05000346/L-2017-LLR-0088, 000976/05000412/L-2017-LLR-0088, and 000976/05000440/L-2017-LLR-0088) L-17-253, Supplemental Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 8052017-10-0909 October 2017 Supplemental Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 805 L-17-233, High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information, Per 10CFR50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force (NTTF) Review of Insights from the Fukishima Dai-ichi Accident2017-08-0202 August 2017 High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information, Per 10CFR50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force (NTTF) Review of Insights from the Fukishima Dai-ichi Accident L-17-189, Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 8052017-06-16016 June 2017 Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 805 ML17163A4122017-06-0808 June 2017 Areva, ANP-3542Q1NP, Revision 0, Response to NRC Request for Additional Information on Time-Limited Aging Analysis for the DB-1 Reactor Vessel Internals. L-17-158, Reply to Request for Additional Information Re License Renewal Commitment No. 422017-05-12012 May 2017 Reply to Request for Additional Information Re License Renewal Commitment No. 42 L-17-070, Reply to Request for Additional Information Related to License Renewal Commitment2017-02-22022 February 2017 Reply to Request for Additional Information Related to License Renewal Commitment L-16-371, Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 8052017-01-17017 January 2017 Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 805 L-16-345, Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Cnfpa) Standard 8052016-12-16016 December 2016 Response to Request for Additional Information Regarding License Amendment Request to Adopt National Fire Protection Association Cnfpa) Standard 805 L-16-323, Spent Fuel Pool Evaluation Supplemental Report, Response to NRC Request for Information Pursuant to CFR 50.54(f) Regarding Recommendation 2.1 of the Near Term Task Force Review of Insights from Fukushima Dai-inchi Accident2016-12-0909 December 2016 Spent Fuel Pool Evaluation Supplemental Report, Response to NRC Request for Information Pursuant to CFR 50.54(f) Regarding Recommendation 2.1 of the Near Term Task Force Review of Insights from Fukushima Dai-inchi Accident L-16-291, Response to Generic Letter 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools2016-11-0101 November 2016 Response to Generic Letter 2016-01, Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools L-16-279, Reply to Request for Additional Information Related to License Renewal Commitment 422016-09-26026 September 2016 Reply to Request for Additional Information Related to License Renewal Commitment 42 L-16-123, Completion of Required Action by NRC Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events2016-09-23023 September 2016 Completion of Required Action by NRC Order EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events L-16-256, Response to Request for Additional Information Regarding a Request to Revise the Emergency Plan2016-09-0606 September 2016 Response to Request for Additional Information Regarding a Request to Revise the Emergency Plan L-16-220, Response to Regulatory Issue Summary 2016-09, Preparation and Scheduling of Operator Licensing Examinations.2016-07-20020 July 2016 Response to Regulatory Issue Summary 2016-09, Preparation and Scheduling of Operator Licensing Examinations. L-16-085, Request for Additional Information Response Related to Modification of Technical Specification 5.3.1, Unit Staff Qualifications.2016-03-22022 March 2016 Request for Additional Information Response Related to Modification of Technical Specification 5.3.1, Unit Staff Qualifications. L-16-079, Supplemental Information for License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 8052016-03-0707 March 2016 Supplemental Information for License Amendment Request to Adopt National Fire Protection Association (NFPA) Standard 805 L-16-040, Response to Request for Additional Information Regarding License Amendment Request to Revise Emergency Diesel Generator Minimum Voltage and Frequency Surveillance Requirements2016-02-19019 February 2016 Response to Request for Additional Information Regarding License Amendment Request to Revise Emergency Diesel Generator Minimum Voltage and Frequency Surveillance Requirements ML15299A1432015-10-19019 October 2015 Additional Information for the Advisory Committee on Reactor Safeaquards Review of the License Renewal Application, Including Enclosure a, Bechtel Affidavit L-15-268, Response to Request for Additional Information Regarding License Amendment Request to Revise Emergency Diesel Generator Minimum Voltage and Frequency Surveillance Requirements2015-10-14014 October 2015 Response to Request for Additional Information Regarding License Amendment Request to Revise Emergency Diesel Generator Minimum Voltage and Frequency Surveillance Requirements ML15280A2872015-10-0606 October 2015 Additional Information for the Advisory Committee on Reactor Safeguards Review of License Renewal Application L-15-263, Response to Request for Additional Information Related to Security Plan Changes2015-08-17017 August 2015 Response to Request for Additional Information Related to Security Plan Changes L-15-197, Response to Request for Additional Information Regarding a Request to Amend Technical Specification 5.5.15. Containment Leakage Rate Testing Program2015-06-26026 June 2015 Response to Request for Additional Information Regarding a Request to Amend Technical Specification 5.5.15. Containment Leakage Rate Testing Program 2023-03-01
[Table view] |
Text
FENOC' 2' 5501 North State Route 2 FirstEnergy Nuclear Operating Company Oak Harbor, Ohio 43449 Brian D. Boles 419-321-7676 Vice President, Fax: 419-321-7582 Nuclear September 26, 2016 L-16-279 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Davis-Besse Nuclear Power Station, Unit No. 1 Docket No. 50-346, License Number NPF-3 Reply to Request for Additional Information Related to License Renewal Commitment 42 (CAC MF7626)
By letter dated April 21, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16112A079), FirstEnergy Nuclear Operating Company (FENOC) submitted a Fatigue Monitoring Program evaluation for Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS), to address License Renewal Commitment 42.
By email dated August 26, 2016, the NRC staff requested additional information on the Fatigue Monitoring Program evaluation to complete its review.
The Attachment provides the FENOC reply to the NRC request for additional information.
There are no regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Patrick McCloskey, Manager- Regulatory Compliance, at (419) 321-7274 .
Sincerely, Brian D. Boles
Davis-Besse Nuclear Power Station, Unit No. 1 L-16-279 Page 2
Attachment:
Reply to Request for Additional Information Related to Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS), License Renewal Commitment 42 cc: NRC Region Ill Administrator NRC Resident Inspector N RC Project Manager Utility Radiological Safety Board
Attachment L-16-279 Reply to Request for Additional Information (RAI) Related to Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS),
License Renewal Commitment 42 Page 1 of 10 By letter dated April 21, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16112A079), FirstEnergy Nuclear Operating Company (FENOC) submitted a Fatigue Monitoring Program evaluation for Davis-Besse Nuclear Power Station, Unit No. 1 (DBNPS), to address License Renewal Commitment 42.
By an email dated August 26, 2016, the NRC staff requested additional information on the Fatigue Monitoring Program evaluation to complete its review. The requested information is provided below. The NRC staff request is shown in bold text, followed by the FENOC reply.
NRC STAFF RAI
Background
Section 2.C(11), "License Renewal Conditions," of Renewed Facility Operating License No. NPF-3 specifies that the Commitments in Appendix A of NUREG-2193, Supplement 1, "Safety Evaluation Report Related to the License Renewal of Davis-Besse Nuclear Power Station," published April 2016 (ADAMS Accession No. ML16104A350), are part of the DBNPS Updated Final Safety Analysis Report.
License renewal Commitment No. 42 in Appendix A of NUREG 2193, Supplement 1, states the following:
Enhance the Fatigue Monitoring Program to:
- Evaluate additional plant-specific component locations in the reactor coolant pressure boundary that may be more limiting than those considered in NUREG/CR-6260 1* This evaluation will include identification of the most limiting fatigue location exposed to reactor coolant for each material type (i.e., [carbon steel] CS, [/ow-alloy steel]
LAS, [stainless steel] SS, and [nickel-based alloy] NBA) and that each bounding material/location will be evaluated for the effects of the reactor coolant environment on fatigue usage. Nickel-based alloy items will be evaluated using NUREGICR-69092* Submit the evaluation to the NRC 1 year prior to the period of extended operation.
1 NUREG/CR-6260, "Application of NUREG/CR-5999 Interim Fatigue Curves to Selected Nuclear Power Plant Components, dated February 1995, ADAMS Accession No. ML031480219.
2 NUREG/CR-6909 "Effect of LWR Coolant Environments on the Fatigue Life of Reactor Materials," dated February 2007.
Attachment L-16-279 Page 2 of 10 Enclosure B of the licensee's letter dated June 17, 2011 (ADAMS Accession No.
ML11172A389}, provides AREVA Report No. 51-9157140-001. Table 3-9 of the AREVA Report contains the environmentally-assisted fatigue (EAF) values for the NUREG/CR-6260 locations. Table 3-8 of the AREVA Report contains a summary of the reactor coolant system pressure boundary locations with environmentally-adjusted cumulative usage factor (CUFen) values that exceed the limit of 1.0.
In its April 21, 2016,, letter, the licensee submitted the results of its evaluations associated with Commitment No. 42. The letter stated that locations were screened in accordance with the methodology of Electric Power Research Institute (EPRI) Technical Report 1024995, "Environmentally Assisted Fatigue Screening[:] Process and Technical Basis for Identifying EAF Limiting Locations," dated 2012. The letter also identified the most limiting locations for each of the four material types (i.e., CS, LAS, SS, and NBA). The CUFen values are provided for two of the four limiting locations. The CUFen values are not provided for the LAS and NBA locations. The LAS and NBA locations reference EPRI Technical Report 1024995.
The April 21, 2016, letter, describes the results of the licensee's evaluation and references the generic methodologies (e.g., EPRI Technical Report 1024995) used, but it does not provide sufficient details about the actual evaluation. The plant-specific methodology and criteria used to select the most limiting locations for EAF is not clearly described. The letter does not explain how the plant-specific screening methodology conservatively evaluates EAF effects, with the same degree of analytical rigor for all locations, to identify the bounding locations. Additionally, the licensee uses different material types to bound limiting locations for LAS and NBA without justification.
EPRI Technical Report 1024995 has not been submitted to the NRC for approval and has not been endorsed by the NRC. The licensee does not explain how the plant-specific implementation of the generic procedures in EPRI Technical Report 1024995 will identify the most limiting plant-specific locations. The NRC staff lacks sufficient information to evaluate the plant-specific methodology and criteria used to select the most limiting locations for EAF.
Attachment L-16-279 Page3of10 Request (1) Describe the plant-specific methodology and criteria used to rank locations and select the most limiting locations for EAF. Describe relevant factors for each step of the process, such as thermal zones, material types, transient complexity, temperature effects, and complexity of the systems (as applicable). Justify the use of different material types to bound locations.
Justify that the process is appropriately conservative.
(2) Describe and justify any engineering judgement, plant-specific assumptions, and plant-specific criteria used in the EAF analysis or screening process.
This should include the systematic process used to eliminate locations as limiting and examples showing how the process was implemented.
(3) Describe how the screening process was applied to the locations in Table 3-8 of the AREVA Report No. 51-9157140-001.
(4) State the locations being managed by the fatigue monitoring program to maintain the CUFen values below the limit of 1.0 through the period of extended operation. Provide the CUFen values for the locations being managed by the fatigue monitoring program.
FENOC REPLY TO RAI (1) Describe the plant-specific methodology and criteria used to rank locations and select the most limiting locations for EAF. Describe relevant factors for each step of the process, such as thermal zones, material types, transient complexity, temperature effects, and complexity of the systems (as applicable). Justify the use of different material types to bound locations.
Justify that the process is appropriately conservative.
To reduce the size of the set, a location was eliminated if it met one of the following prescreening criteria:
- The location has a usage factor that is so low that, even if the maximum possible environmental fatigue correction factor (Fen) were applied, the resulting EAF usage factor (Uen) would be less than 0.8, which is the example EAF screening limit provided in EPRI Technical Report 1024995.
- The location is not exposed to reactor water, and therefore EAF is not applicable.
- The location is not part of the primary pressure boundary and is therefore excluded from the EPRI screening process.
Attachment L-16-279 Page 4of10 Sentinel locations are determined based on the locations remaining after prescreening. Sentinel locations are those locations chosen for more detailed analysis or monitoring. These locations are chosen to have bounding Uen*
(estimated Uen) compared with other locations. Estimated Uen is determined using an estimated Fen. Estimated Fen (Fen*) is calculated as the average of the value based on a qualitative estimate of strain rate, and the value based on the worst possible strain rate, using the same values of dissolved oxygen and estimated upper bound temperature for design transients in both cases.
Based on the locations that pass prescreening, each location is conservatively assumed to exist in its own thermal zone. Therefore, the rules in the EPRI screening process for reducing the number of sentinel locations across thermal zones are used as follows:
- One thermal zone (that is, location) can bound another thermal zone (location) in a system if the cumulative usage factor (CUF) and Fen values for one sentinel location in one thermal zone are each higher than those for the sentinel locations in other thermal zones, and the Uen is more than twice those in the other zones.
- One material in a thermal zone (location) can bound other materials in the same thermal zone (location) if the CUF and Fen values for one sentinel location composed of one material are each higher than the CUF and Fen values for the sentinel locations composed of all other materials, and the Uen is more than twice those for the other materials.
- One material in a thermal zone can bound other materials in another thermal zone if both of the preceding two criteria are true.
The limiting locations were then evaluated per NUREG/CR-6260, Section 4.3, "Potential Adjustments to Licensees' Calculations that Might Reduce the CUF," to determine sources of conservatism in the existing fatigue usage calculations.
As described in FENOC letter L-11-203 dated June 17, 2011 (ADAMS Accession No. ML11172A389), the Reactor Coolant Pump Bearing Cavity, Pressurizer Heater Bundle Diaphragm Plate and Diaphragm Plate Seal Weld each had EAF values greater than 1.0, requiring a detailed analysis. Detailed analyses were completed for those components with EAF values greater than 1.0, and the results were provided in FENOC letter L-16-148 dated Apri l 21, 2016 (ADAMS Accession No.
ML16112A079).
Attachment L-16-279 Page 5of10 (2) Describe and justify any engineering judgement, plant-specific assumptions, and plant-specific criteria used in the EAF analysis or screening process.
This should include the systematic process used to eliminate locations as limiting and examples showing how the process was implemented.
Assumptions used in the evaluation :
- The initial screening applied a conservative Fen multiplier to each location.
This approach is conservative since the Fen factor considered the worst strain rate of 0.0004%/sec and dissolved oxygen level of 0.05 ppm, which results in higher (conservative) Fen values.
- Each location that initially screens in is conservatively assumed to exist in a separate thermal zone.
The screening process is conservative since the original usage factors are determined based on the design transient cycles. The design transient cycles are bounded by the 60-year projected cycles (reference FENOC letter L-11-166 (ADAMS Accession No. ML11159A132}, EnclosureTable4.3-1, "60-Year Projected Cycles"), which are currently tracked under the Davis-Besse Allowable Operating Transient Cycles (AOTC) Program.
No credit is taken for components that were recently replaced to screen out limiting locations. Recently replaced components include those associated with the reactor vessel closure head and control rod drive mechanisms (2011 }, steam generators (2014) and reactor coolant system hot leg piping between the flow meter and the steam generators (2014).
The screening of initial sentinel locations is shown in Table 1, "Screening of Initial Sentinel Locations."
Attachment L-16-279 Page 6 of 10 Table 1: Screening of Initial Sentinel Locations System Location Material Fen
Fen u Uen Not Bounded?
Type smaller? smaller? <half! 6260?
RV continuous vent nozzle, I-groove weld Ni-Cr-Fe 4.784 0.90 4.31 TRUE TRUE TRUE TRUE TRUE RC pump cover, cooling hole ligament (Note 1) SS RC pump cover, bearing cavity SS 13.117 0.964 12.64 FALSE FALSE FALSE TRUE FALSE PZR spray nozzle, internal pipe SS 9.013 0.33 2.97 TRUE TRUE TRUE TRUE TRUE PZR heater bundle closure, diaphragm plate SS 11.486 0.6 6.89 TRUE TRUE FALSE TRUE FALSE PZR heater bundle closure, seal weld SS 11.486 0.86 9.88 TRUE TRUE FALSE TRUE FALSE PZR manway closure, studs LAS 2.455 0.35 0.86 TRUE TRUE TRUE TRUE TRUE Spray piping (Node 73) SS 9.013 0.5184 4.67 TRUE TRUE TRUE TRUE TRUE Spray piping (Node 74) SS 9.013 0.0951 0.86 TRUE TRUE TRUE TRUE TRUE Spray piping (Node 80) SS 9.013 0.4124 3.72 TRUE TRUE TRUE TRUE TRUE RC Letdown piping (Node 859) SS 13.117 0.604 7.92 FALSE TRUE FALSE TRUE FALSE RC drain nozzles SS 15.348 0.132 2.03 FALSE TRUE TRUE TRUE FALSE Hot leg, new upper 180° elbow cs 1.740 0.827 1.44 TRUE TRUE TRUE TRUE TRUE SG primary manways LAS 2.455 0.34 0.83 TRUE TRUE TRUE TRUE TRUE SG primary manway seal weld (Note 2)
SG primary handhole cover LAS 2.455 0.37 0.91 TRUE TRUE TRUE TRUE TRUE SG primary handhole seal weld (Note 2)
SG inlet nozzle primary head juncture LAS 2.455 0.79 1.94 TRUE TRUE TRUE TRUE TRUE SG tubesheet, postulated thin ligament, primary LAS 2.455 0.39 side 0.96 TRUE TRUE TRUE TRUE TRUE SG lower spherical/flat head juncture LAS 2.455 0.33 0.81 TRUE TRUE TRUE TRUE TRUE
Attachment L-16-279 Page 7 of 10 Table 1: Screening of Initial Sentinel Locations (cont.}
System Location Material Fen
Fen u Uen Not Bounded?
Type smaller? smaller? <half? 6260?
SG tubes Ni-Cr-Fe 4.784 0.36 1.72 TRUE TRUE TRUE TRUE TRUE RC SG tube seal welds Ni-Cr-Fe 4.784 0.42 2.01 TRUE TRUE TRUE TRUE TRUE SG tube plug seal welds Ni-Cr-Fe 4.784 0.23 1.10 TRUE TRUE TRUE TRUE TRUE Decay heat nozzle cs 1.740 0.89 1.55 TRUE FALSE FALSE TRUE FALSE Decay heat containment isol. valves SS 9.568 0.14594 1.40 TRUE TRUE FALSE TRUE FALSE DHR Low pressure injection check valves SS 9.568 0.14099 1.35 TRUE TRUE FALSE TRUE FALSE Low pressure injection containment isol. valves SS 13.117 0.18261 2.40 FALSE FALSE FALSE TRUE FALSE CF Core.flood piping (Node 490) SS 9.013 0.582 5.25 FALSE FALSE FALSE TRUE FALSE Note 1 - This location is exposed to component cooling water and not Reactor Coolant, therefore is not evaluated for EAF.
Note 2 - This cover is sealed using gaskets, and the seal weld was never made. Therefore, fatigue calculations are not needed .
RC = Reactor Coolant OHR = Decay Heat Removal CF = Core Flood ing
"
Attachment L-16-279 Page 8 of 10 (3) Describe how the screening process was applied to the locations in Table 3-8 of the AREVA Report No. 51-9157140-001.
The screening process described in response to Request 1 of this RAI was applied to all non-NUREG/CR-6260 reactor coolant pressure boundary components exposed to reactor coolant water listed in Tables 3-1 through 3-7 of AREVA Report No. 51-9157140-001 3 that are not exempt from fatigue, and not just those components previously identified in Table 3-8 with EAF CUF greater than 1.0. The locations evaluated are based on current plant design and analysis. The EAF associated with the reactor vessel closure head and control rod mechanisms (2011), steam generators (2014) and hot leg portion between the flow meter and the steam generators (2014) have changed due to replacements.
In addition to the components listed in AREVA Report No. 51-9157140-001, the following valves were also evaluated for EAF:
- decay heat containment isolation valves
- decay heat bypass containment isolation valves
- low pressure injection containment isolation valves (4) State the locations being managed by the fatigue monitoring program to maintain the CUFen values below the limit of 1.0 through the period of extended operation. Provide the CUFen values for the locations being managed by the fatigue monitoring program.
The Davis-Besse Allowable Operating Transient Cycles (AOTC) Program tracks the actual number of plant transients. The program prevents the fatigue time limited aging analysis (TLAA) from becoming invalid by assuring that the fatigue usage resulting from actual operational transients does not exceed the Code design limit of 1.0, including environmental effects where applicable. The procedure uses the systematic counting of transient cycles and the evaluation of operating data to ensure that the allowable cycle limits are not exceeded, thereby ensuring that component fatigue usage limits are not exceeded. Transient documentation is updated at least once per plant operating cycle.
3 AREVA Report No. 51-9157140-001, "DB-1 Design CUFs and NUREG/CR-6260 Screening for License Renewal," dated June 10, 2011 was included as an Enclosure to FENOC letter L-11-203 dated June 17, 2011 (ADAMS Accession No. ML11172A389).
Attachment L-16-279 Page 9of10 When the sum of the transients in the AOTC Logs indicate that the total number of transients is within 75% of the designated number of design cycles or within 10%
of the 60-year projected cycles for any transient classification, a condition report shall be initiated. Some of the EAF evaluations used 60-year projected cycles versus design cycles. The 60-year projected cycles are more limiting than the design cycles and therefore, become the allowable when considering environmental effects. When the accumulated cycles approach the allowable cycles, corrective action is taken that includes an engineering evaluation to ensure the Code design limit of 1.0 is not exceeded, including environmental effects where applicable. For transient cycles that are projected to exceed the allowable cycle limit by the end of the next plant operating cycle (Davis-Besse operating cycles are normally two years in duration), the corrective action shall include an update of the fatigue usage calculation for the affected component(s). Acceptance criterion is to maintain the cumulative fatigue usage below the Code design limit of 1.0 through the period of extended operation, including environmental effects where applicable.
All non-NUREG/CR-6260 locations evaluated for EAF are evaluated for at least the 60-year projected Cycles documented in FENOC letter L-11-166 (ADAMS Accession No. ML11159A132), Enclosure Table 4.3-1, "60-Year Projected Cycles,"
with the following exceptions. The pressurizer heater bundle diaphragm plate and seal weld were evaluated for the best estimate 60-year heatup and cooldowns of 114 (reference FENOC letter L-11-203 dated June 17, 2011 (ADAMS Accession No. ML11172A389)) instead of 128. Locations for the core flood piping, letdown piping, Low Pressure Injection (LPI) check valves, LPI containment isolation valves, and OHR containment isolation valves as listed in Table 2 are currently evaluated for one transient number 11 (rod withdrawal accident), 18 (loss of feedwater heater), and 28 (maximum probable earthquake (OBE)) since these transients have not occurred. The limiting number of transients evaluated in the EAF analysis will be tracked in the AOTC program as the transient cycle limit.
Therefore, all locations are managed by the Fatigue Monitoring Program.
The CU Fen values for locations that screen out as described in the FENOC response to Request 1, above, were not determined. Table 2, below, lists the CUFen value for the components evaluated .
Attachment L-16-279 Page 10of10 Table 2: EAF Usage Factors (Uen)
Material Location Uen Type Reactor Coolant Drain Nozzle and Adjacent SS 0.8866 Piping*
Core Flood Piping Point 490 SS 0.61 Letdown Piping Point 859 SS 0.73 Low Pressure Injection Check Valves SS 0.14 Low Pressure Injection Containment Isolation SS 0.20 Valves Decay Heat Removal Containment Isolation SS 0.19 Valves Decay Heat Removal Nozzle, CS Portion cs 0.92 RCP Cover, Bearing Cavity SS 0.49 Pressurizer Heater Closure, Plate SS 0.92 Pressurizer Heater Closure, Seal Weld SS 0.75
- Uen determined using NUREG/CR-6909 rules. The strain amplitude is less than the strain amplitude threshold of 0.10% in all cases, Fen does not need to be applied.