L-09-332, Discharge Monitoring Report (NPDES) Permit No. PA0025615
| ML093631135 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 12/22/2009 |
| From: | Lieb R FirstEnergy Nuclear Operating Co |
| To: | Office of Nuclear Reactor Regulation, State of PA, Dept of Environmental Protection, Bureau of Water Quality Management |
| References | |
| L-09-332 | |
| Download: ML093631135 (57) | |
Text
FEI~cyNOkaCp ~~
cm Beaver Valley Power Station Route 168
.- 0. Box 4 Shippingport, PAý 15077-0004 December 22, 2009 L-09-332 Department of Environmental Protection Bureau of Water Quality Management Attention: DMR Clerk 400 Waterfront Drive Pittsburgh, PA 15222
SUBJECT:
Beaver Valley Power Station Discharge Monitoring Report (NPDES) Permit No.
PA0025615 Enclosed is the November 2009 NPDES Discharge Monitoring Report (DMR) for FirstEnergy Nuclear Operating Company (FENOC), Beaver Valley Power Station, in accordance with the requirements of the Permit. Attachment 1 to this letter is supplemental monitoring data for Outfall 001 (dissolved oxygen). A review of the data indicates no permit parameters were exceeded during the month.
Should you have any questions regarding the attached and enclosed documents, please direct them to Mr. Michael Banko at 724-682-4117.
Sincerely, iaymon A. LiebO Director, Site Operations
Beaver Valley Power Station, Unit Nos. 1 and 2 L-09-332 Page 2 Attachment(s):
- 1. Weekly Dissolved Oxygen Monitoring Results at Outfall 001 Enclosure(s)
A. Discharge Monitoring Report cc:
Document Control Desk US NRC (NOTE: No new US NRC commitments are contained is this letter.)
US Environmental Protection Agency
Discharge Monitoring Report Attachment for NPDES Permit No. PA0025615 L-09-332
,FirstEnergy Nuclear Operating Company (FENOC)
Beaver Valley Power Station ATTACHMENT 1 Weekly Dissolved Oxygen Monitoring Results at Outfall 001 The following supplemental dissolved oxygen monitoring data for Outfall 001 is provided as agreed.
SAMPLE DATE SAMPLE TIME VALUE UNITS 11/2/09 0935 8.97 mg/L 11/9/09 1515 8.56 mg/L 11/16/09 0850 9.31 mg/L 11/23/09 1430 8.94 mg/L 11/30/09 0920 8.50 mg/L
- Attachment 1 END -
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 1
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBE 001A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNITS 1&2 COOLG. TOWER BLWDN External Outfall No Discharge F-1 FROM 7777MONITORING PERIOD FR MM/DD/YYYY 2
T MM/DD/YYYY FOI11/
01/ 2009 TO 111/
30/
200'9 QUANTITY OR LOADING QUALITY OR CONCENTRATIONNO.
FREQUENCY SAMPLE PARAMETER EX OF ANALYSIS TYPE PARAMETER
'Vi;r-SVALUE VALUE UNITS VALUE VALUE VALUE UNITS pH SAMPLE N/A N/A N/A 8.1 N/A 8.4 pH 0
1 / 7 GRAB MEASUREMENT 00400 1 0 PERMIT
-C0.
t"£0
'k7t mwniW4rym N/A
~
~
nr~'
-~
,f~
Effluent Gross REQUIREMENT ryan........
3/4. IiMINIMW
- t.
LK
,4MA'IMUIM pH e...ys.
GB Nitrogen, ammonia total (as N)
SAMPLE N/A N/A N/A N/A
<0.1
<0.1 mg/L 1 / 7 GRAB MEASUREMENT Effluent Gross REQUIREMENT t:*:i.
r&.S
- j.
MOAG(
,AL'QX mo/L r7r*G t, *i-,:*.*?**~,
-t*
CLAMTROL CT-1, TOTAL WATER SAMPLE N/A N/A N/A N/A GG GO GG GG GG MEASUREMENT 04251 1 0 PERMIT N/Ak or,
'L
,t2,3/4M'.>
When Effluent Gross REQUIREMENT I
ffl.*7 u
(-
.kM@A ADAlt.tMX*
molL
- eDisoharglng -,-
SAMPLE Flow, in conduit or thru treatment plant MEASUREMENT 5 4 MOD N/
N N/A N/A 50050 1 0 PERMIT R-q "Itr Mon Rý,I~y IJ;fvI
/
ýDiy
-~
OTN Effluent GrossREQUIREMENT MOAVG DA-iL4AMX:
Mgal/d 4
Wj~
2
.aa' N
Chlorine, total residual SAMPLE N/A N/A N/A N/A 0.0 0.02 mg/L 0
7 I 30 GRAB MEASUREMENT 500601 0 PERMIT I
N/A Effluent NA 4
GRB Effluent Gross REQUIREMENT
,A E
I M..
4mg/L Chlorine, free available SAMPLE N/A N/A N/A N/A 0.0 0.5 mg/L 0
CONT RORD MEASUREMENT 5 0 0 6 4 1 0 P E R M I T I*n
' Q 0 -
' 5 A r'
Effluent Gross REQUIREMENT N/A AVERAGEM U
m o/L itn.4 4
Hydrazine SAMPLE/A(5 Hyrzn ESURMPEN N/A N/A N/A N/A
<0.005
<0.005 mg/L 0
1 / 7 GRAB HyrzieMEASUREMENT m /
81313 1 0 PERMIT 3/4,.*n,.~w
~
lv
.,,4 Effluent Gross REQUIREMENT VJq K
NA MOVG 5 JDIYee/L
- ly NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I ceriy under penalty of lam that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualitied personnel D
properdy gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE pemsons who manegethe system or. those persons dirently responsible for gathering the 724 682-7773 12/ 22/ 2009 information, the information submitted is, to the best ot my knowledge and belief. true, accurate, O PERATIO NS and complete. I am ewane that there one significant penalties tor submitting talse information, including tre possibility of fine and imprisonment for knowing violations.
SIGNA E OF PRINCIPAL EXECUTIVE OFFICER OR TYPEO OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD(YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING. THE LIMIT IS 35 MG/L AS A DAILY MAX.
The plant was in wet layup during the first three weeks of this period. WMC 12-10-09 Computer Generated Version of EPA Form 3320-1 (rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 2
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAIMGR ENV & CHEM PA0025615 PERMIT NUMBER 0002A~
DISCARGENMBER11 DMR MAILING ZIP CODE:
150770004 MAJOR
('SUBR05)
INTAKE SCREEN BACKWASH External Outfall No Discharge F1 MONITORING PERIOD MM/DDIYYYY MMIDDIYYYY FROM 11/
01/
2009 TO 11/
30/ 2009 NAMErTITLE PRINCIPAL EXECUTIVE OFFICER t certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel property gather and e-atuate (he information submitted, Based on my inquiry of the person or I
Raymond A. Lieb, DIRECTOR OF SITE persons. wh manage the system.. orthose rsers directy responsiblefor gatherin the 724 682-7773 12/ 22/ 2009 information, the information submeied is. to the best of my knowledge and belief, true, accurate, OPERATIONS and complete. I am aware that there are significant penalties for submining false information.
including the possibility of fine and imprisonment for knowing violations, S
NA EFFICER OR A
TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DDIYYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 3
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAiMGR ENV & CHEM PA0025615 PERMIT NUMBER 003A I
DISCHARGE NUMBER]
DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 003 External Outfall No Discharge F--
MONITORING PERIOD MM/DDIYYYY I
MM/DD/YYYY FROM 11/
01/
2009 TO 11/
30/ 2009 certify under penalty of law that thin deoument ard all ahaohmeets mere prepared unoer wy I
I
.NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Raymond A. Lieb, DIRECTOR OF SITE OPERATIONS I eritiy under penalty of law that this document and all attachments were prepared under my direction or supervrsion in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persoes who manage the system, or those persons directly responsible for gathering the inf ormaton. the information submitted is, to the best oa my knowledge and belief, true, accurate, and complete I am aware that there are significant penahties for submitting false information.
including the possibility of fine and imprisonment for birowing violations.
TYPED OR PRINTED AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
THE FLOWS FOR OUTFALLS 103, 203, 303, AND 403 ARE TO BE TOTALED AND REPORTED AS THE 003 FLOW.
Computer Generated Version of EPA Form 3320-1 (rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 4
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA00256 1
5 PERMIT NUMBER 004A DISCHARGE NUMBER DMR MAILING ZIP CODE:
.150770004 MAJOR (SUBR05)
UNIT ONE COOLG TOWER OVERFLOW External Outfall No DischargeLFKJ MONITORING PERIOD MM/DD/YYYY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
30/ 2009 TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all atlachments here)
Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Fomen Approved 0MB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION, LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBE 006A DISCHARGE NUMBER Page 5
DMR MAILING ZIP CODE:
150770004, MAJOR (SUBR05)
AUX. INTAKE SCREEN BACKWASH External Outfall No Discharge MONITORING PERIOD MM/DDj/YYY0 I
MM/DDTM/
FROMI Ill 01/
20091 TO 11/
30/
20 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER t certity under penalty of law that this document and all attachments were p ditection or supervision in accordance with a system designed to assure th.
Raymond A. Lieb, DIRECTOR OF SITE OPERATIONS TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attach property gather and enaluate the information submitted. Based on my inquiry of the person or persons who manage the system. or those persons directly responsible for gathering the information, the information submitted is. to the best of my knowiledge and belief, true, ancurate, and complete. I am aware that there are signihicant penaltties for submitting false information, including the possibitity of fiee and imprisonment for Irrowing iolations torents here)
ComputaGenerated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
'if
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Fom-Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBfER 007A
[DISCHARGE NUMBER Page 6
DMR MAILING ZIP CODE:,
150770004 MAJOR (SUBR05)
AUX. INTAKE SYSTEM External Outfall MONITORING PERIOD MM/DD/YYYY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
30/
2009 No DischargeL-1 NAMETITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under mypOTELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the intormation submitted. Based on my inqoiry of the person or Raymond A. Lieb, DIRECTOR OF SITE pesons who rmanagethesystrem. orthose prsons directtyreponsible teforgatherng the inrtrmation, the intormation submitted is. to the best of my knowledge and beliet. true, dccurate, 724 682-7773 12/ 22/ 2009 O P E RATION S anrd complete. I am aware that there are significant penalties for submitting false intormation.
including the possibility of fine and imprisonment tor knowing violations.
SIGNA RE OF RINCI L EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here) l MONITORING FOR FLOW, FREE AVAILABLE CHLORINE, AND TOTAL RESIDUAL CHLORINE ARE REQUIRED ONLY DURING THOSE PERIODS OF DISCHARGE.FROM THE ALTERNATE FLOW PATH OF THE REACTOR PLANT RIVER WATER SYSTEM.
Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Fomi Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 7
- NAME:
ADDRESS:
FIRST ENERGY NUCLEAR OPERATING PA ROUTE 168 SHIPPINGPORT, PA 150770004 PA0025615 PERMIT NUMBER 008A IDISCHARGE NUMBER FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM DMR MAILING ZIP CODE:ý 150770004 MAJOR-(SUBR05)
UNIT 1 COOLING TOWER PUMPHOUSE External Outfall No DischargeL-*
MONITORING PERIOD MM/DD/YYYY MMIDD/YYYY FROM 11/
01/
2009 TO 11/
30/
2009 NAMEITITLE PRINCIPAL EXECUTIVE OFFICER I certify undor penalty of lew teat this document and all attachment, were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the informaton submitted, Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons who manage the system. or those persons directly responsible for gathering the I
724 682-7773 12/ 22! 2009 intormation, the information submitted is, to the best of my keossedge and belief, true. accurate.
7 OPERATION S arid complete. I tam ear that there are significant penalties for submating false information.
including the possibility of fine and imprisonment for knowing violations SIGNATIRE OF PRINCIPAL EXECUYIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
Computer Generated Version of EPA Form 3320-1 (rev. 01106)
Page 1
NATIONAL P 9LLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT fDMR)
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:.
FIRST ENERGY NUCLEAR OPERATING ADDRESS:,
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAIMGR ENV & CHEM PA0025615 N
PERMIT NUMBER DICARGE UMBER Form Approved OMB No. 2040-0004 Page 8
DMR MAILING ZIP CODE:
150770004 -
MAJOR (SUBR05)
UNIT 2 COOLING WATER External Outfall No Discharge F1 MONITORING PERIOD FR M
/ DD/YYY1 I
MM/DDfY`YY FROMý 11/
01/
20 TO 1 11/
30/
25009 QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE PARAMETER EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS pH SAMPLE N/A N/A N/A 7.9 N/A 7.9 pH 0
1 7
GRAB
~~MEASUREMENT 00400 1 0 PERMIT
¢-,-,6T d,
""'t
- h*C*
9.. " *
-- ~cs'I>
N/A
~
~
o u
E ffl uent G ross R E Q U IR EM E N T pH,*
M,
.F M.U M H
ý,l
'G R CLMRLC-,TTLWTR MAUEET N/A N/A N/A N/A GG GG mg/L GG GG GO Effluentros04 Gross RQUREQUIREMENT
- '"*"*d**y n..
)
%uy
- r
, y
- =.tM
/A.AyG*/*
iM r k 2,**
- lNS*',*,
M X 0
,. m IL Dis
!har t*;:,
COMP2-4*
SAMPLE Flow, in conduit or thru treatment plant ESRMLE 7.2 101 MGD N/A N/A N/A N/A 1 I 7 MEAS MEASUREMENT 50050 1 0 PERMIT cR'IMo:$i*Re
-M~n*;y
- t.
N/A MEASRD Effluent Gross REQUIREMENT I i /M
- VGV AL X~
M al/d Weiy<
SAMPLE Chlorine, total residual MEASUREMENT N/A N/A N/A N/A
<0.02
<0.02 mg/L 0
1 / 7 GRAB Effluent Gross REQUIREMENT
-g/L Chlorine, free available MSUMPE N/A N/A N/A N/A
<0.02
<0.02 mg/L 0
1 i 7
GRAB MEASUREMENT 50064 1 0 PERMIT P
n Ot.**5 yhecn r*:;I My Effluent Gross.
REQUIREMENT lm NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certity under penalty t lawc thot this doncument and all attachrnents.c... prepared under sty
- T L P O ED T
directien or super-uision In accordanteowith a systenm designed to assure that qualified perseonel T L P O ED T
property gather and evaluate the intormration submitted. eased en rey inquiry of the person en Raymond A. Lieb, DIRECTOR OF SITE pe....n. whr...... gethe syste......those pe....s dirnetty responsibleteogathecingthe 724 682-7773 t2/ 22/ 2009 information, the infotrmation submirtted is. to toe best or my knowledgte and belief, true, accurate.
OPERATIONS crd complete. i......
tamtn ther ar... significant penalties tor subritting raise intormation, iN
~
FPICPL CIIEOFCRO C h lerin en and itopa lso rrreat toP knoN Ang Nio tAtio
- s.
A ECNeATN U M B ERPL E U IVY TYPED OR PRINTED AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS SReference all attachmentsohere)
REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING (24 HR.T COMP.)
MG/L. (THE LIMIT IS 35 MG/L AS A DAILY MAX)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBER DIC 011A DISCHARGE NUMBER Form Approved OMB No. 2040-0004 Page 9
DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
DIESEL GEN & TURBINE DRAINS External Outfall No Discharge[j MONITORING PERIOD MM/DD[YYYY 200MMTDD/2 FO I
11/1 01/
2009 TO 1 11/
30/ 2009 PARAMETER.
QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX, OF ANALYSIS TYPE VALUE VALUE UIS VALUE VALUE VALUE UNITS Flow, in conduit or thru treatment plant 500501 0 Effluent Gross
- AIV I. L "
MEASUREMENT 0.004 0.004 MGD N/A I
N/A N/A N/A 1/7 EST PERMIT
< P IJ Pq I*7*
REQUIREMENT I
%'AV(
M,*
1?.*
,ý IOAUJYM Mgal/d I
or..
.1 r
~~~~N/A ee y';IE l&
I NAME/TITLE PRINCIPAL EXECUTIVE OFFICER
..cify under penalty of law that this docurent and all attachrents wore prepared under myTELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons. who managethe system, or those persons dinecty respensible for gathering the 724 682-7773 12/ 22/ 2009 information, the information submitted is, to the best of my knowledge and beliefn true. accurate.
OPERATIONS and complete. I tam awarthat there.are significant penalties for submitting false information.
including the possibility of fine and imprisonment for knowing violations OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 10 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA002561 PERMIT NUMBER I
012A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
BLOWDOWN FROM THE HVAC UNIT External Outfall
-- MONITORING PERIOD MM/DD/[YYY I
MM/DD0YYY/
FROM 111/
01/
20091 TO 11/
30/ 2009 No DischargeElI PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS pH 00400 1 0 Effluent Gross bAMlLl MEASUREMENT N/A N/A N/A 8.5 N/A 8.5 pH 0
1 / 30 GRAB ME------------IE...
IE-PERMIT
.2 -
",t*
j
-r REQUIREMENT N/A MINIMUMI I I. vi d I,
1e i9' i&~ ~i DH SAMPLE Copper, total (as Cu)
MEASUREMENT N/A N/A N/A N/A 0.1152 0.1610 mg/L 0
2 / 30 GRAB 01042 1 0 PERMIT
- *,r.u' Mon...
P L
--ot-N/A Mrý,
F-.- ~~~RB Effluent Gross REQUIREMENT NAIIY X
mg/L SAMPLE Zinc, total (as Zn)
MEASUREMENT N/A 0.1 0.2 mg/L 0
2 / 30 GRAB Effluent Gross REQUIREMENT 11-r AALMn m,/L r
t*dbth*,
SAMPLE]
Flow, in conduit or thru treatment plant SUME
<0.001
<0.001 MGD N/A N/A N/A N/A 1 / 30 EST MEASUREMENTI 50050 10 PERMIT ~ir (eMf
):r.ce~~-~NA
~
SIA Effluent Gross REQUIREMENT I*/a. MA
,?, AILY-MX*g*
Mgal/d,g P-
-U=
,,4io, SAMPLE Solids, total dissolved SUME N/A N/A N/A N/A 608 632 mg/L 0
2 / 30 GRAB MEASUREMENT m/
70295 1 0 PERMIT
,2 t'4RO**a 4
Ž a,.
,con
- i-r*Req'M.n.
Tv,',-
T...:P-*e
,Effluent Gross REQUIREMENT o
-I--
7 NAiMO AVr~GN4 DIYM mg/L O
ýZIpiiGRth1 NAMErrITLE PRINCIPAL EXECUTIVE OFFICER dcenity, uoder penalty of loon that thia document and all attachmrents were prepared uoder rmy TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE paronr. who manage the system. or those persons directly responsiblefor gathering the 724 682-7773 12/ 22/ 2009 information, the information submitted is, to the best of my knowledge and belief, true, accurate, OPERATIONS and complete. tam aware that thete are significant penalties for submitting false information.
including the possibilily of fine and imprisonment lotr knowing violations, SIGNAT RE OF PRINCIPKL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD!YYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all antachments here)
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 11 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM P
M0025615 PERMIT NUMBER
~013A I
DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
OUTFALL 013 External Outfall MONITORING PERIOD FROM MM/DD/
0 FO I
11/
01/
2009 T
MM/DD/YYYY TO 11/
301 2009 No Discharge F--
QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE PARAMETER EX OF ANALYSIS TYPE u:-'
VALUE VALUE UNITS VALUE VALUE VALUE UNITS pH SAMPLE N/A N/A N/A 6.7 N/A 7.2 N/A 0
1 / 7 GRAB MEASUREMENT COUP 0061bPERMIT
.~<-r
~#*o N/A I,-
u ~
~rr Effluent Gross REQUIREMENT
-i 4rK jr.;
- -ri*lNIMW XH Cyanide, total (as CN)
SAMPLE N/A N/A N/A N/A 0.01 0.01 N/A 0
2 / 30 COMH MEASUREMENTC 00720 1 0 PEMI
[-"IA i-**c*-wie!
Effluent Gross REQUIREMENT N/AMu.
A*
W I
- GRdMi.MX c"'
MTi[ir n Corotal SAMPLE 24 HR MEASUREMENT 0
N/A 0
2 / 30 COMP 01042 1 0 PERMIT Pit' n"e I
-g'4,
.1-T*i ei*:*
COM.
Effluent Gross REQUIREMENT
- K.
-Y'r"nr' M0t.
~u~ns~r
~
MOVG~K-~-rBll/~X mgIL Month Chlorobenzene SAMPLE N/A
<0 005N N/A 42 30 ESM MEASUREMENT 34301 1 0 PERMIT N/A
,:Rea MonnOC I
N/A RqfV j
Effluent Gross REQUIREMENT L,-
Ma/
M.
K-*//Dl;iY*M mLn C
P SAMPLE iu
- 141b Flow, in conduit or thru treatment plant MEASUREMENT 0.002 0.002 MGD N/A N/A N/A NA2
/ 30 EST 500010PERMIT Pr:
Ii-
"e o
~coNA~:~~>~
Twice Peri EfletGosREQUIREMENT LESTIMAMgl/
NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty or law thar
-this dT.unen... d air attachments were prepared under my/TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel property gather and enaluate the information submitted, Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons wh managethe system, or hose persons directly responsible for gathering the 724 682-7773 12! 22/ 2009 information, the information submitted is, to the best of my knowledge and belief, true, accurate, OPERATIONS end complete. I am aware that there arc significant penalties for submhtring false information.
including the possibility of fine and imprisonment for knowing niotation SIGNATORE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS.
.o r..er Vrsono
.E.. Frm 33.-..
o.....
Pa e Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE. MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 12 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBE 101A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 101 CHEMICAL WASTE TREATMENT Internal Outfall No Discharge j-MONITORING PERIOD MM/DD/Y`YY`Y I
MMTDD/fYYYY 11/IIl 01/
20091 TO 11/
301 2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervsion in accordance with a system designed to assure that qualifed personnel property gather and evetuate tho information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE ersonswho manao.gethe syst..ort.hos.. persons dorectly responsible for gathering the 724 682-7773 12/ 22/ 2009 information, the information submitted is, to the best of my knowledge and belief, true, accurate.
OPERATIONS andcomplote I......
that there are sgnificant penalties for submithng false informatAon.
O CU F
E including the possibility of fine and imprisonment for know0ng violations.
SIC FFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DDTYYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. SAMPLES SHALL BE TAKEN AT THE DISCHARGE FROM THE CHEMICAL WASTE SUMP PRIOR TO MIXING WITH ANY OTHER WATER.
Plant in wet layup during the first three weeks of this period. WMC 12-10-09 Computer Generated Versoon of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 13 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBE 102A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 102 INTAKE SCREEN HOUSE Internal Outfall No Discharge*j MONITORING PERIOD MM/DD/YY T
MMIDDIYYYo 11/
01111 201/
TO 1 11/
30/ 2009 11-1 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Raymond A. I-eb, DIRECTOR OF SITE OPERATIONS I oeoify under penalty of law that this document and all attachments were prepared under my direction or sup-rvlsion in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system. or those persons directly responsible for gathering the information. the reformation submitted is, to the best of my knowledge and belief, true. accurate, and complate.
l am aware that there are significant penalties for submitting false infarmation, including the possibility of fine and imprisonment for knowing violations.
SIGNATURE OF PRINCIPAL EXECUTIVE TYPED OR PRINTED AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE DISCHARGE OF COLLECTED PUMP BEARING LEAKAGE PRIOR TO MIXING'WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 14 PERMITTEE NAME/ADDRESS (include, Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING
. ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM 215 108A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD/YYYY I
MMTDDOI YYY FO I
11/
01/
20091 TO 1 11/
30/ 2009 DMR MAILING ZIP CODE:
150770.004 MAJOR (SUBR05)
SLUDGE SET-TLING BASIN Internal Outfall No DischargeF-1 COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE OVERFLOW FROM THE BASIN PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/061 Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004, PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 15 I PRMT NUMER-DISCHARGE NUMBERt DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 111 DIESEL GENERATOR BLDG Internal Outfall No DischargeF-1 MONITORING PERIOD MM/DD/YYYY I
MM/DD/YYYY FROM 11/
01 2009 TO 11/
30/
2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Raymond A. Lieb, DIRECTOR OF SITE OPERATIONS TYPED OR PRINTED COMMENTS AND EXPLANATION:OF ANY VIOLATIONS (Reference all attac I certify under penalty of law that this document and all attachments wmre prepared under my
/
),.
,i
/
TEL direction or supervsion in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system. or those persons directty responsible for gathering the 724 information, the rformation submitted is, to the best of my knowledge and belief, true. accurate.
and complete. I am aware that there are significant penalties for submitting false information.
including the possibility of fine and imprisonment for knowing violations.
IRN CER OR AUTHORIZED AGENT AREA Code EPHONE 682-7773 1I DATE 12/ 22/ 2009 NUMBER MM/DD/YYYY hments here)
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIQNAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) 41 DISCHARGE MONITORING REPORT (DMR)
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAIMGR ENV & CHEM PA00E25615 PERMIT NUMBER 113A,
DISCHARGE NU;MBE]R Form Approved OMB No. 2040-0004 Page 16 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 2 SEWAGE TMT PLANT Internal Outfall No Discharge L--*
NO.~
~
~
FRQEC SAPL MONITORING PERIOD MM/DD /YYY0 I
MMIDDf/YYY FO I
11/
01/
20091 TO 11/
30/ 2009 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE VX OF ANALYSIS TYPE VALUE VALUE UNITS VALU VALUE VALUE UNITS pH 0o0oo 1 0 Effluent Gross MEASUREMENT PERMIT REQUIREMENT 1 <11.
1 v$
i~i-~,~/-.:
,v~rr.v-~
MINIMI IM.1121'
~
- L 1A~IKIU~Th, 2TT~
1 r~ T R~T~I~2 -r2v nH SAMPLE Solids, total suspended MAME MEASUREMENT 00530 1 0 PERMIT
,30 460r T i
.'v,-
Effluent Gross REQUIREMENT I
MO,,
--,r-rMOAVG-,,
flLY IIX4*,:
mg/L Floyd, in conduit or thru treatment plant SAMPLE MEASUREMENT 500501 0 PERMIT.
(J42~'
2'~M~T~~r'2l
/A r
v.-r Effluent Gross REQUIREMENT N/AMO
-AVG)EL
.i)AILY1M )t M al/d EASR SAMPLE Chlorine, total residual M A M E NT MEASUREMENT' 50060 1 0 PERMIT
-~>4
- o-
-j4
.ieer'"
Effluent Gross REQUIREMENT Tm/LM Coliform, fecal general SUME MEASUREMENT 74055 1 1
-PERMIT
-~4
~O*1A~
Zr>
wc e
Effluent Gross REQUIREMENT
- d.
MO*Ed*
i,,,
,#/lO0mL,Mon h
BOD, carbonaceous, 05 day 20 C SAMPLE MEASUREMENT 80082 1 0 PERMIT
-**O r
5 t*<
Effluent Gross REQUIREMENT MO i'
1
-DAILY_,
j m./L M
COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT OVERFLOW FROM THE CHLORINE CONTACT TANK PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
PA0025615 203A jPERMIT NUMBER ARGE NUMBER F-MONITORING PERIOD MMIDD/YYYY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
301 2009j Form Approved OMB No. 2040-0004 Page 17 DMR MAILING ZIP CODE:
'150770004 MAJOR (SUBR05)
MAIN SEWAGE TMT PLANT Internal Outfall No Discharge F--
NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Raymond A. Lieb, DIRECTOR OF SITE OPERATIONS certify under penalty of law that this document and all attachments were prepared under my irection or supervision in accordance with a system designed to assure that qualified personnel roperly gather and uealuate the information submitted. Based on my inquiry of the person or ersons who manage the system, or those persons directly responsible for gathering the nformation, the information submitted is. to the best of my knowledge and belief, true, accurate, nd complete tam aware that there are significant penalies for submiting false information.
nctuding the possibility of fine and imprisonment for knowing violations.
SIGMATURE OF PRINCIPAL EXECUTIVE 0F1 TYPED OR PRINTED AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT OVERFLOW FROM THE CHLORINE CONTACT TANK PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 18 PA0025615 211A PERMIT NUMBER DISCHARGENLUMBERI F
MONITORING PERIOD FR MM/DD[YYYY TO MM/DDIYYYY FROMI 111/ 01/
20091T 1
11/1 30/12069 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 211 TURBINE BLDG Internal Outfall No Discharge ---
I Irort~vUr'vIrIItI I
COMMENTS AND EXPLANATION OF ANY VIOLATIONS iReference all attachments here)
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 19 NAME:
FIRST ENERGY NUCLEAR OPERATING
-ADDRESS:
PA ROUTE 168, SH!PPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 I
213A PERMIT NUMBER I DISCHARGE NUMBERI IMONITORING PERIOD FR MM/DD/YYYY I
I MM/DDTYYYO FOI 111 01/
2009 TO 1 11/
30/ 2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 2 COOL TOWER PUMPHOUSE Internal Outfall No DischargeLF-1 NAMEITITLE PRINCIPAL EXECUTIVE OFFICER lcedtiy utnder penalty Of law that tbis documrent arid all attachmoents atone prepared under moy
.e TLPO ED E
direction or supervision in accordance with a system designed to assure that qualtfed personnel propedy gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE Persons whmr
.n..gathersysten,.
orthose persons directly responsible for gathering the 724 682-7773 12/ 22/ 2009 intornation, the information submitted is. to the best of my knowledge and belief, true, accurate, OPERATIONS arid complete, I.
aware that there ate significant penalties tor submitting false information.
ihnluding rho possibility of fine and imprisonment for knowing violations.
SIGN URE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT DISCHARGE FROM THE PUMP HOUSE PRIOR TO MIXING WITH ANY OTHER WATER. NOTE: THE MONITORING OF THIS DISCHARGE IS NOT REQUIRED WHEN EFFLUENT FROM UNIT NO. 2 COOLING TOWER PUMP HOUSE FLOOR & EQUIPMENT DRAINS IS BEING RECYCLED TO THE UNIT NO. 2 WATER RECIRCULATION SYSTEM.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 20 PA0025615 PERMIT NUMBER 301A
]
DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 2 AUX BOILER BLOWDOWN Internal Outfall No Discharge F-j F
"MO"NITORING PERIOD R
MM/DDf/YYY T
MM[DD/YYYY-FROMI 111/ 01/
20091 TO 11/
30/
200-9 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS Solids, total suspended 00530 1 0 Effluent Gross MEASUREMENT N/A N/A N/A N/A
<4
<4 mg/L 0
2 / 30 GRAB f
PERMIT
)
REQUIREMENT t
r N/A I
DAILY, ~
I
~
I
'4~-X
'I.<'AF mg/L SAMPLE N/A N/A N/A N/A
<5
<5 mg/L 0
2 / 30 GRAB Oil & grease MEASUREMENT
<5 00556 1 0 PERMIT N/
I L~~Pr Effluent Gross REQUIREMENT A',1,3 L-2 N/A "mcf.,
- t.
<nL..
o..
SAMPLE<001
<.0 MGNANANANA1/7 ES Flow, in conduit or thru treatment plant MEASUREMENT
<0.001 0.001 MOD N/A 1
50050 1 0 PERMIT
'R.,t',ri iu4?
N/A Effluent Gross REQUIREMENT "MOAG
- ,>:,},DAILYM M
drir__
rit NAMEITITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of lawt thet this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted, Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons who marage thesyste...r.thoseprn.....
directly responsible forgathering the 724 6827773 12/ 22/ 2009 inforration. the information submitted is. to the best of my knowledge and belief, true, accurate.
O PERATIONS and Womptete.
I.....
re that thnr are significant penalties for submitting false information.
including the possibility of fine and imprisonment for knowing violations.
AREA Cd P
NUMBER MM/DDSYYYY TYPED OR PRINTED AUTHORIZED AGENT AREA Code COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE DISCHARGE OF BOILER BLOWN DOWN PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 21 PA0025615 303A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MFM/DD/YYYY T
I MM/DD/YY FROMI 11/
01/
2009 TO 1 11/
30/ 2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 1 OIL WATER SEPARATOR Internal Outfall No Discharge F j
PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS MEASUREMENT N/A N/A N/A 7.2 N/A 7.4 pH 0
1/
7 GRAB I ~
94/i.
+
4.....~+
~4.....4 4
-~
00400 1 0 Effluent Gross PERMIT N/A
~v.
~.uo:,il,~yryv>y..2 :2TX? V I..,
~..,
N/A nt-I
',,Ir,,ý I"
ý i;F'4f' W*1 SAMPLE Solids, total suspended MEASUREMENT N/A N/A N/A N/A 5
13 mg/L 0
1 / 7 GRAB 005301 0 PERMIT O
O*"
3Q P
100 Effluent Gross REQUIREMENT N/
1/
MO)AG r
4Ž7)DAILY MX:mg/L ky.--.-- GRAB SAMPLE Oil & grease MEASUREMENT N/A N/A N/A
<5
<5 mg/L 0
1 / 7 GRAB 00556 1 0 PERMIT
- 00*0*.'
- d*e
,e*yo
-ii 15:r N/A hO
~
Wely GA Effluent Gross REQUIREMENT 41~~~~
MOA~
ALM mg/L_________
SAMPLE Flow, in conduit or thru treatment plant MEASUEENT 0.019 0.056 MGD N/A N/A N/A N/A 1
/ 7 EST MASUREMENTANA S
50050 10 PERMIT
ý:qýc Req7 Mhi:A
-,wwo I0 0...
N/AF Effluent Gross REQUIREMENT O AG DA-ILYMX,,uu Mgal/d
- VWeekJ,
.. ESTIMA NAME/TITLE PRINCIPAL EXECUTIVE OFFICER oerirty under penalty of law thot this document and all atachiments were prepared under my TELEPHONE DATE dection or superision In accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted, Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons. wro managethe system or. those persons directly responsible for gathiering the 724 682-7773 12/ 22/ 2009 information, the information submitted is. to the best of my knowledge and belief. true. accurate, O PERATIONS and complete. Iam aware that there are significart penalties for submitting falseinformatior.
including the possibility of fine and impnsonment for knowing violations.
SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE OVERFLOW FROM THE OIL WATER SEPARATOR PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page I
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR).
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAIMGR ENV & CHEM PA0025615Y PERMIT NUMBER 31'3Aou DISCHARGE NUMBER~
Foem Approved
.OMB No. 2040-0004 Page 22 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 313 TURBINE BLDG DRAIN Internal Outfall No DischargejE MONITORING PERIOD MM/DDIYYYY I
MM/DDIYYYY FROM 11/
01/
2009 TO 11/
30/ 2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certfy under penalty of lawe that this document and all attachments were prepared under my TELEPHONE DATE direction or superorsion In accordance with a system designed to assure that qualified personnel property atther and ecaluate the infiormation submitted. Based on my inquiry of the person or Kevin L. Ostrowski, DIRECTOR OF SITE persons. who
.mangethe syste..
orthose persons directly responsible forgatheringthe 724 682-7773 12/ 22! 2009 information, the information submitted is. to the best of my knowledge and betiet, true, accurate, OPERATIONS and complete. Iam aware that there are s4gmficant penaties for sobmtting tease information.
including the possibility of fine and imprisonment tor lnowing uiolations, SIGN URE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MMIDD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT DISCHARGE FROM OWS #21 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
PERMITTEE NAME/ADDRESS (incfude Facflity NVame/Location dDifferent)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 401A PERMIT NUMBER DISCHARGE NUMBER FROMONITORING PERIOD IMMDDIYYYY I
MMIDD/YYYY FROM 11/
01/
2009 TO 11/
30/ 2009 Form Approved OMB No. 2040-0004 Page 23 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
CHEM.FEED AREA OF AUX BOILERS Internal Outfall No Discharge[I II cerity under penalty of law that this document and all attachmnents were prepared under my direction or supervision in accordance ewith a system designed to assure that qualified personn Ipropergalher and ealuate the lntormation submited. 8ased on myinqury ofthe person or persons who manage the system. or those persons directly responsible for gathering the information. the information submitted is, to the best of my knowledge and belief, true, securert and complete. I am aware that there are significant penalties for submitting false information.
COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT CHEMICAL FEED AREA DRAINS PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAM EIADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING
- ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBER 403A DISCHARGE NUMBER Page 24 DMR MAILING ZIP, CODE:
150770004 MAJOR (SUBR05)
CONDENSATE BLOWDOWN & RIVR WAT Internal Outfall No Discharge j
MONITORING PERIOD MM/DD/YYYY TO MMIDD/YYYY FROM 11/
01/
2009 TO 1 11/
30/ 2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under my TELEPHONE direction or supervision in accordance with a system designed to assure that qualified personnel TE property gather and evaluate the irformation subitted, Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons. whr emanage the system or. those parsons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate.
724 682-7773 12/ 22/ 2009 O P E RATIOIN S and complete, I am aware that there urn signifiCant penahies for submhting false Information, including the possibility of fine and rmprisonment for knowing violations.
SIGNATRE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING (24 HR. COMP.):
MG/L. (THE LIMIT IS 35 MG/L AS A DAILY MAX.) SAMPLES SHALL BE TAKEN AT MP 403 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 25 PERMITTEE.NAME/ADDRESS (include Facility Name/Location if Different)
NAME:.
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUM I
403A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004.
MAJOR (SUBR05)
CONDENSATE BLOWDOWN & RIVR WAT Internal Outfall No Discharge
-x-MONITORING PERIOD MMFDDIYYYY 1
1MM/DD/YYYY FROMI 11/
01/
2009 TO 1 11/
30/
2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel propedy gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons whn managethe system, or those persons directly responsibletorgahering the 724 682-7773 12/ 22/ 2009 information, the mnformation submitted is, to the best of my knowledge and beliet, true, accurate.
OPERATIONS and complete. I am aware that there are significant penalties for submitting false information.
including the possibility of fine and imprisonment for knowing violations.
SIGN URE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING (24 HR. COMP.):
MG/L. (THE LIMIT IS 35 MG/L AS A DAILY MAX.) SAMPLES SHALL BE TAKEN AT MP 403 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 2
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved.
OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 26 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 E
PERMIT NUMBfER SDISCHARGE NUMBERI DMR MAILING ZIP CODE:, 150770004 MAJOR (SUBR05)
BULK FUEL STORAGE DRAIN Internal Outfall No DischargeFj*
MONITORING PERIOD MMIDD/YYYY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
30/ 2009 S.direction or supervision in aceordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE person sho. managethe system. orthose perons directly responsible forgathering the information. the information submitted is, to the best or my knowledge and belief, true. accurate, OPERATIONS ard vomptete. t e auare that there
.e.
significant penalties for submitting false information, inrduding the possibitity of fine and imnrrsonment for hnowrsg violations.
TYPED OR PRINTED3 COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT DISCHARGE FROM OWS #24 PRIOR TO MIXING WITH ANY OTHER WATER.
computer Generated Version of EPA Form 3320-1 IRep. 011061 Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved 0MB NO. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 27 NAME:
- FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM
[
P005615 7 PERMT NUMBER
' 501A, DISCHARGE NUMBER DMR MAILING.ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 1 GENRTR BLWDWN FILT 8W Internal Outfall No Discharge[*
FROM
'MONITORING IPERIOD MM/DD/YYYY MM/DD/YYYY FRM 11/
01/
2009 TO 11/
30/ 2009 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS Solids, total suspended 00530 1 0 Effluent Gross SAMPLE MEASUREMENT PERMIT REQUIREMENT L
- em*
~u'-
30~'~
~
(5(5 tO'i~i4.
t->-,~,
--iv ~'u-
-~
~,
1/2eswvrsay, ssr~nu C
~
4MOAVG~.
~DAItoY M m /L ~V..
n
~
~
~o Flow, in conduit or thru treatment plant 50050 1 0 Effluent Gross SAMPLE MEASUREMENT
..... i i¸
- i i* i* ¸ y
- ii¸
=
11 =:
= *
- PERMIT M6*i~i
'R*'M.*n*
REQUIREMENT *:M rAVG,7/*V,.*;
DA!IY.MX-,
Mgal/d
- 05*5*
-~ '5
- ~n>~4.
Iproperty gather and enatuate the information submitted. Based no roy inquiry of the person or persons who manage Che system. en those persons directly responsible to, gatheriog the intormatione.tha rnformation submitted is. to the best of my knowledge and belief true. accuratn.
and comrplete. I ann emore toot nonre are significant nenatties ten subm*'inq fatne intormation.
inctuding the possibility ot fine and iorprisonment ton tinowrsng violations.
COMMENTS AND EXPLANATION OF ANY VIOLATIONS IReference all eggachments hterel SAMPLES SHALL BE TAKEN AT INTERNAL MP 501 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 1
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM P
TPA0025615 E
PERMIT NUMBER]
001A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNITS 1&2 COOLG. TOWER BLWDN External Outfall I
MONITORING PERIOD FROM L MD/0Y20 TOI MMIDD0YYY0 FRM 1!/
01/
20091 TO 111/
30/ 2009d No Discharge j7 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS N/A N/A N/A 8.1 N/A 8.4 pH 0
1 /7 GRAB MEASUREMENT MEASUREMENT
-~.~r.o~rv ru..~s' IsotrtnnsrSnnru ntl
.on~~.t ts si iti5h4......
> oxw.
00400 1 0 Effluent Gross REQUIREMENT
~.4futf~~iifry,0 N/A OMAXIMJJMr 7 PH Nitrogen, ammonia total (as N)
SAMPLE N/A N/A N/A N/A
<0.1
<0.1 mg/L 1 / 7 GRAB MEASUREMENT 006101 0 PERMIT IDW 1
fM NA 6n..
'.'F.-2GA Effluent Gross REQUIREMENT I
M....G.
NA"11 F
MXtur m /L CLAMTROL CT-1, TOTAL WATER SAMPLE N/A N/A N/A N/A GG GG GG GG GG MEASUREMENT 04251 1 0 PERMIT N/A.0..
.h f
Effluent Gross REURMNN/A
,ias..
r~-
-~
~
OP-.
SAMPLE Flow, in conduit or thru treatment plant MEASUREMENT4 MGD N/A Effluent Gross REQUIREMENT MO AVIG
-,DMLY MX' Mgal/d i
N, TIN SAMPLE Chlorine, total residual MEASUREMENT N/A N/A N/A N/A 0.0 0.02 mgI/L 0
7 / 30 GRAB 50060 10 PERMIT i~
1 ih.*00it,'51 Effluent Gross REQUIREMENT L
'6A mg/L SAMPLE Chlorine, free available SUME N/A N/A N/A N/A 0.0 0.5 mg/L 0
CONT RCRD MEASUREMENT 500641 0 PRI 2
0~u~,ttria<
~
f s
/-,,:~j 77~Cn~dIiROD Effluent Gross PEQREMNT N/A A
s HydrzineSAMPLE Hydrazine MESURMPEN N/A N/A N/A N/A
<0.005
<0.005 mg/L 0
1 / 7 GRAB MEASUREMENT 1
/
,UUm/
813131 0 PERMIT r
nt**om d.,:,
i*..
WkG E ffl u e n t G ro s s R E Q U IR E M E N T N /A r"V.
"/L 1.,
NAMEITITLE PRINCIPAL EXECUTIVE OFFICER difynundeu penalty of law that this document and all attachments were prepared under my TELEPHONE DATE dpretion or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted Based on my nquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE p esons whn managethe system or. (hose persons directly responsibletorgathering tha 724 682-7773 12/ 22! 2009 information. the information submitted is. to the best of my knowledge and belief, true, accurate, OPERATIO NS and complete. I am. are that thee are significant penalties for submiting false information.
includtng the possibility of fine and imprisonment for knowing violations.
SIGNA RE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DDIYYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments herel HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING. THE LIMIT IS 35 MG/L AS A DAILY MAX.
The plant was in wet layup during the first three weeks of this period. WMC 12-10-09 Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Fornm Approved OMB No. 2040-0004 PERMITTEE NAMEIADDRESS (include Facility Name/Location if Different)
Page 2
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 1
FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615Y PERMIT NUMBER 002A DISCHARGE NUMBER DMR MAILING ZIP CODE:
.150770004 MAJOR (SUBR05)
INTAKE SCREEN BACKWASH External Outfall No Discharge F--I MONITORING PERIOD MMJDDfYYY
)00 MMTJDDOj YYY FROMI 11/
01/
2009 TO L_
11/
30/
25009-Computer Generated Version of EPA Form 3320-1 (rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERM-ITEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 3
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025 6 15 003A PERMIT NUMBER DISCHARGE NUMBER FROMONITORING PERIOD FR MM[DD/lYYYY I
MMTDID 0YYY FOI 111 01/
20091 TO 1 11/
30/
2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 003 External Outfall No Discharge Fj I
NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I
NAMEITITLE PRINCIPAL EXECUTIVE OFFICER Raymond A. Lieb, DIRECTOR OF SITE OPERATIONS TYPED OR PRINTED Icanniy undar penalty of larw that this document and all attachments wre prepared under my
/*
=
f J
direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry or the person or persons who manage the system, or those persons directly responsible for gathering the information, the information subnitted is. to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penafties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
S-IlGNAT16RE OF PRINCIPAL EXECUTIVEO AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
THE FLOWS FOR OUTFALLS 103, 203, 303, AND 403 ARE TO BE TOTALED AND REPORTED AS THE 003 FLOW.
Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No, 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 4
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBER 004A DISCHARGE NUMBER DMR MAILING ZIP CODE:
,150770004 MAJOR (SUBR05)
UNIT ONE COOLG TOWER OVERFLOW External Outfall No Dischargel E
_O°MONITORING PERIOD FR MM/DD/YYYY I
I MM/DD/YYYY FOI 11/
01/
2009 TO 1 11/
30/ 2009 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE TUNITS VALUE VALUE VALUE UNITS pH 00400 1 0 Fff~l J~n frncv N/A MEASUREMENT PERMIT RFQUIRFMENT N/A
~MAMWM~
-4
~
9~ ~>
AB~
nH SAMPLE Flow, in conduit or thru treatment plant MEA SNMPE MASUREMENTI 50050 1 0 PERMIT F1'Rq'Mdrf k
ReFýq-Mon.
~
r-*NAWel MAR Effluent Gross REQUIREMENT
,.MO AVG,-.
L~YM Mgal/d 4
SAMPLE Chlorine, total residual MAUENTNIA 500601 0 PERMIT
- O
- 5.
12_
Effluent Gross REQUIREMENT mg/rNAM VG.-~-t Weky vGA SAMPLE Chlorine, free available MEASUREMENT N/A 500641 0 PERMIT
.N O***,
"*2.,
,.GRAB*
Effluent Gross R~EQUIREMENT N/A:
L F'AEAEMXMM m L-o r_
COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here) computer Generated Version otEPA Form 3320-1 Iree. 01/061 Page 1 Computer Generated Version of EPA Form 3320-1 (rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 5
PA0025615 006A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD/YYY0 MMTDD/YYYY FO I
11/
01/
20091 TO 1 11/
30/
2009' DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
AUX. INTAKE SCREEN BACKWASH External Outfall No Discharge j-j PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS Flow, in conduit or thru treatment plant bAMIjLL MEASUREMENT 50050 1 0 PERMIT Effluent Gross REQUIREMENT 0.002 0.016 MGD N/A N/A I
N/A N/A 1/7 EST R,
-Moll-I0
.Ž rl,
~..-~
.~~:Ii>~- >L
~~
N/A
~
~
-~SjM MnIn~/r NAMEMTITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under my
/
j TELEPHONE DATE direction or supecrvsion in accordance with a system designed to assure that qualifed personnel propedy gather and evaluate the information submided. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE perso.ns wh managethesystem. orthose persons dircty responsibleforgatherigthe 724 6827773 12/ 22/ 2009 information, the information submitted is. to the best of my knowledge and belief, true, accurate, OPERATIONS and complyte. tam awere that there are eignificant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR.
TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 6
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM S
PA0025615 PERMIT NUMBER
~007A DISCHARGE NUMBER DMR MAILING ZIP CODE:-
150770004 MAJOR (SUBR05)
AUX. INTAKE SYSTEM External Outfall No Discharge j
MONITORING PERIOD MMIDD
/YYY I
I MM/DDT/20 11MI l/
01/
2009 TO 1 11/
30/
2009 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS I_
I______
I______ -______
_1____
E FNLS TP pH 00400 1 0 F ffitua.nt flrAne 5AMPLE MEASUREMENT PERMIT T
- 7-I*1lh1IIIPIM I*1JT i-.
B
-e-**~7.{ I
~
.1
~
- LJ SAMPLE Flow, in conduit or thru treatment plant MEASUREMENT 50050 1 0 PERMIT tPk*_1Mc L[RiýiýKIi' M
ey 1,*
.QRAB Effluent Gross REQUIREMENT 07'MA
- * *-DAIIt Ugal/d-SAMPLE Chlorine, total residual MAME MEASUREMENT 50060 1 0 PERMIT
!"2)=
- 3/4 l
"=$* *We*.y' GRAB Effluent Gross REQUIREMENT AVG-Ij" I 1NMA, S§AMPLE Chlorine, free available MEASUREMENT 500641 0 PERMIT EEfuntGoslRQIRMETnt____Gross__
_______REQUIREMENT_____________________________________________
NAMEI11TE PRINCIAL EXECUIVE OFFIER oertty under penally ofla thaelot this document and all attachmenots were prepared under remyEEPOEDT direPtiRo or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE personsnuro hn.a.gethetsystem.. or hose persons directly responsibletor galering the 724 682-7773 12/ 22! 2009 Irtformation, the information submitted is, to the best of my Xnewledge and belief, true, accurate.
OPERATIONS aid uomplten. tam eare, that there are sig.i.... nt peý.o nis for submitting
- alse information.
ncluding the possibility of fine and imprisonment for knowing violations.
SG RE OF RINCI L EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MMIDD/YYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
MONITORING FOR FLOW, FREE AVAILABLE CHLORINE, AND TOTAL RESIDUAL CHLORINE ARE REQUIRED ONLY DURING THOSE PERIODS OF DISCHARGE FROM THE ALTERNATE FLOW PATH OF THE REACTOR PLANT RIVER WATER SYSTEM.
Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
- NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAIMGR ENV & CHEM IPA0025615' PERMIT NUMBER 008A
[DISCHARGE NUMBER Page 7
DMR MAILING ZIP CODE:
150770004
- MAJOR, (SUBR05)
UNIT 1 COOLING TOWER PUMPHOUSE External Outfall No Dischargef MONITORING PERIOD MMIDD/YY Y MM/DDT/YYY FO I
11/
01/
209 TO 1 11/
301 260509 COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here) uompulor ~ener~Iod Version 0? 61-'A -orm 13A)-1 Irev. 01106)
Page 1 Computer Generated Version of EPA Form 3320-1 (rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
I DISCHARGE MONITORING REPORT (DMR)
Form Approved 0MB No. 2040-0004 PERMITTEE NAM E/ADDRESS (include Facility Name/Location if Different)
Page 8
NAME: -
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 I
,010A PERMIT NUMBER
[DISCHARGE NUMBER MONITORING PERIOD MM/DD[YY I
MMIDD0YYYY 11/
01Ill 2011 TO 1 11/
30/ 2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 2 COOLING WATER External Outfall No Discharge COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING (24 HR. COMP.):
MG/L. (THE LIMIT IS 35 MG/L AS A DAILY MAX)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 9
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBE 011A DISCHARGE NUMBER DMR MAILING ZIP CODE:
MAJOR (SUBR05) 150770004 MONITORING PERIOD MMIDDIYYYY MMIDD/YYYY FROM 11/
01/
2009 TO 11/
30/
2009 DIESEL GEN & TURBINE DRAINS External OutfaJI No Discharge Fj QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE PRMTRIEX OF ANALYSIS TYPE PARAMETER, z
VALUE VALUE UNITS VALUE VALUE VALUE UNITS Flow, in conduit or thru treatment plant SAMPLE 0.004 0.004 MGD N/A N/A N/A N/A 1 / 7 EST MEASUREMENT 50050 1 0 PERMIT
-ReVý YR'Mf~~
i rX1 N/A~STM
,Effluent Gross REQUIREMENT :
M1~O'AV,ŽA. 7 2 I b~L
'i" Mgal/d '~t>
- ~~.Wk' COMMENTS AND EXPLANA TION OF ANY VIOLATIONS (Reference all attachments here)
Computer Generated Version of EPA Form 3320-1 IRev. 01/061 Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 10 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 012A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD/iYYYY 0 MM/DDT/YYY FRM 11/
011 20091 TO 11/
30/ 2009 DMR MAILING ZIP CODE:
MAJOR (SUBR05) 150770004 BLOWDOWN FROM THE HVAC UNIT External Outfall No Discharge F -
NAME/TTLE PRINCIPAL EXECUTIVE OFFICER 1 ventity under penalty at lava that this docnment and all aft-nnsmr peae ne
~T L P O ED T
direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE pnsons wht rumangethe system. yr tuho persona direcyresponsibletor gatherling the 724 682-7773 12! 22! 2009 information, the information submitted is. to the best of my knowledge and belief, true, accurate, OPERATIONS and complete. I am aware that there are significant penalties tot submitting false information.
including the possibility of tie and imprisonment for knowing violations.
SIGNAT RE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 11 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PEMI025615 R PERMIT NUMBER 01'3A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
OUTFALL 013 External Outfall No Discharge Fj F-MONITORING PERIOD FR MM/DD/2YYY00 MM/DDIYYYY FROMI 11/
01/
20091 TO 1 11/
30/
2009 COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
THERE SHALL BE NO DISCHARGE OF FLOATING SOLIDS OR VISIBLE FOAM IN OTHER THAN TRACE AMOUNTS.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page I
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Forn, Approved OMB No. 2040-0004 Page 12 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAIMGR ENV & CHEM PA0025615 PERMIT NUMBER
- 101A, DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 101 CHEMICAL WASTE TREATMENT Internal Outfall No Discharge j-j MONITORING PERIOD MMIDD/YYYY I
MM/DDIYYYY FROM Ill 01/
2009 TO 11/
30/ 2009 NAMErTITLE PRINCIPAL EXECUTIVE OFFICER I cortify under penalty of law that this document and all attachments were prepared under myOTELEPHONE DATE direction or supervision in accordance with a systenr designed to assure that qualified personnel property gather and evaluate rhe information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons dwho mnrage the systre. or those persons directly responsible for gathering the 724 682-7773 12/ 22/ 2009 intormation. the information submited is. to the best of my knowledge and belief. true,.7cure,e2 OP E RATI O NS n°d comp flete. I..... awrhat ther sgnificant penalties for submittinlg false information, including the possibility of fine and imprisonment for fno rhng iftio a
t i
SIG ATURE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MMIDD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. SAMPLES SHALL BE TAKEN AT THE DISCHARGE FROM THE CHEMICAL WASTE SUMP PRIOR TO MIXING WITH ANY OTHER WATER.
Plant in wet layup during the first three weeks of this period. WMC 12-10-09 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OM6B No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 13 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERAiMGR ENV &CHEM PA0025615 PERMIT NUMBER 1O02A DISCHARGE NUMBER[
DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 102 INTAKE SCREEN HOUSE Internal Outfall No Dischargef---
MONITORING PERIOD MM/DD/YY00 MMIDD/
200 FO I
111 01/
209 TO 1 11/
30/
2009 PARAMETER pH 00400 1 0 Effluent Gross' QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS bAMVLI:
MEASUREMENT N/A N/A N/A 7.8 N/A 7.8 pH 0
2 / 30 GRAB PERMIT o
i REQUIREMENT N/A M IIMINIUM GRAB)
[
oH SAMPLE Solids, total suspended MEASUREMENT N/A N/A NIA N/A 8.7 15.3 mg/L 0
2 / 30 GRAB 00530 1 0 PERMIT 7T
-(-
/
0-4-~~A0~TiePrC NA
-AB~
Effluent Gross REQUIREMENT I
.MSAV DlYX.
mg/L IMnt SAMPLE Oil & grease MEASUREMENT N/A N/A N/A N/A
<5
<5 mg/L 0
2
/ 30 GRAB 005561 0 PERMIT N.**
f-****
T'.e,,
,;er' Effluent Gross REQUIREMENT Mr N/A
/L";"'.,
- 'K ru l 15 "
<2 34't~~~-.
iOAG rAIL-M M /L Flow, in conduit or thru treatment plant SAMPLE
<0.001
<0.001 MGD N/A N/A N/A N/A 2 / 30 EST Flo, n onui o thu retmntplnt MEASUREMENT 500501E 0 PERMIT C et, I
Mgal/d NA" E
Effluent Gross REQUIREMENT U
MO :iA'
-ý
,j~1YX-Mgal/d
,44-7s, 'onh.-
ý1 i.
COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE DISCHARGE OF COLLECTED PUMP BEARING LEAKAGE PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 14 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
ADDRESS:
FIRST ENERGY NUCLEAR OPERATING PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM 5615 10A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD/fYYY I
MM0DD/YYYY FO I
111 01/
20091 TO 1 11/
30/ 2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
SLUDGE SETTLING BASIN Internal Outfall No Discharge F-TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE OVERFLOW FROM THE BASIN PRIOR TO MIXING WITH ANY OTHER WATER.
computer Generated Version of EPA Form 3320-1 IRe". 01/001 Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved 0MB No. 2040-0004 Page 15 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:.
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 111A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD/YYYY I
MM/DD/YYYY FOJ 11/
01/
2009 1TO 11/
30/ 2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 111 DIESEL GENERATOR BLDG Internal Outfall No DischargeF-j NAMEITITLE PRINCIPAL EXECUTIVE OFFICER ndcertidy under penalty of law that this document and aft attahhments were prepared under my directior or superision in accordance with a system designed to assure that qualifed persorn property gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE per..son who maeagethe system, at those persons dircntlyresponsible for gathering the information, the Information submitted is. to the best of my knowledge and belief. true, accurat OPERATIONS and oemplate. lam a.ar that the are. significant penalties for submitting false information, I
TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here) compuler Generofed Version of EPA Form 3320-I IRee. 01106)
Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 16 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 I113A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DDFYRYYY T
MM/DDlY0YYY FOI 11/
01/
20091 TO 11/ 30/
2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 2 SEWAGE TMT PLANT Internal Outfall No Discharge NAMErTITLE PRINCIPAL EXECUTIVE OFFICER I certity Under penalty of low that this document and all attachments were prepared under my direction on supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons. wro rr.nagethe systee. or those persons directly responsibetfor gathering the infor martion. the information submited is, to the best of my knowledge and belief, true, accurate.
OPERATIONS end complete. t r aware that ther
.are significant penalties for submitting false Information.
including the possibility of fine and imprisonment for knowing violations, TYPED OR PRINTED AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT OVERFLOW FROM THE CHLORINE CONTACT TANK PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01P06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if'Different)
Page 17 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PERMTNUMBER I 203A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
MAIN SEWAGE TMT PLANT Internal Outfall No Discharge*-
MONITORING PERIOD MM/DD/YiY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
301 2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Raymond A. Lieb, DIRECTOR OF SITE OPERATIONS I certify under penally of law that this document and all attachments were prepared under my direction or supervision In accordance with a System designed to assure that qualified personnel properly gather and ecaluate the information submrited. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the intor'ation, the information submitted is. to the best of my knowledge and belief, true, accurate, and nomplete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for kneoing violations.
SIGNFATURE OF PRINCIPAL EXECUTIVE OFF TYPED OR PRINTED AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT OVERFLOW FROM THE CHLORINE CONTACT TANK PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 IRen. 01/061 Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
IJATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 18 NAME:
ADDRESS:
FIRST ENERGY NUCLEAR OPERATING PA ROUTE 168 SHIPPINGPORT, PA 150770004 PA00256~15 t
211A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 211 TURBINE BLDG Internal Outfall FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM MONITORING PERIOD MM/DD[YY I
MM/DD/YYYO FROMý 11/
01/
209 TO 1 11/
30/
2009 No DischargeF -
TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS jReference all attachments here) computer Generated Version of EPA Form 3320-1 lRov. 01/061 Page 1 Computer Generated Version of EPA Form 332G-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 19 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168,
SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBER 213A DISCHARGE NUMBER DMR MAILING ZIP CODE:
- MAJOR (SUBR05) 150770004 MONITORING PERIOD MM/DDIYYYY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
30/ 2009 UNIT 2 COOL TOWER PUMPHOUSE Internal Outfall No Discharge Fj NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penally of law that this document and all allachments vare prepared under my TELEPHONE DATE direction or supervision in accordance oith a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE personswhro ranageethesyst.em. otihose persons directly responsible for gathering the 724 682-7773 12/ 22/ 2009 information, the information submitted is. to the best of my knomledge and belief, true, accurate, OPERATIONS and comnplete. I am aerae that thre are significant penalties for submitting false information, including the possibility of fine and imprisonment for knocing violations.
AGEN T AREA CEde U
RFICER ORRERFPC TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/Y"YYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here) w SAMPLES SHALL BE TAKEN AT DISCHARGE FROM THE PUMP HOUSE PRIOR TO MIXING WITH ANY OTHER WATER. NOTE: THE MONITORING OF THIS DISCHARGE IS NOT REQUIRED WHEN EFFLUENT FROM UNIT NO. 2 COOLING TOWER PUMP HOUSE FLOOR & EQUIPMENT DRAINS IS BEING RECYCLED TO THE UNIT NO. 2 WATER RECIRCULATION SYSTEM.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No..2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 20 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 301A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD[YYY-Y MM/DDT[
/YYY FROMI 111 01/
20091 TO 111/
30/
2009 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 2 AUX BOILER BLOWDOWN Internal Outfall No Discharge F-1 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE.
UNITS Solids, total suspended 00530 1 0 Effluent Gross N/A N/A N/A N/A
<4 mg/L 0
2 / 30 GRAB MEASUREMENT A
L........
PERMIT
.*****rr1*.
REQUIREMENT
- j*
.L!
N/A 100
-ILY Nl,',
V.~
~
~ -
I GRAB
~
~MOnth~
I i
A maiL Oil & grease SAMPLE N/A N/A
<5
<5 mg/L 0
2 / 30 GRAB MEASUREMENTI 00556 1 0 PERMIT i
/
20 4
-i')~
~~~
Effluent Gross REQUIREMENT
- '>MO*A*
G D'fl KMX m /L
MohtW<L *-RAB W(
SAMPLE Flow, in conduit or thru treatment plant MEASUREMENT MGD N/A 50050 1 0 PERMIT
,.- ji' F
qd*q.M K
N/A
ýi "I Effluent Gross REQUIREMENT LLM.....
-,.D ill, Y MX, Mga./d
- *,'&i*
b r
>*r'rr
',.4>
COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE DISCHARGE OF BOILER BLOWN DOWN PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168
'SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
PA0025615 303A PERMIT NUMBER DISCHARGE NUMBER MONITORING PERIOD MM/DD1/YYY MMTDD/YYYY FROMI 11/
011/
00 TO 1
111 301 2009 Page 21 Form Approved OMB No. 2040-0004 DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
UNIT 1 OIL WATER SEPARATOR Internal Outfall No Discharge F--
TYPED OR PRINTED AUTHORIZED A COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT THE OVERFLOW FROM THE OIL WATER SEPARATOR PRIOR TO MIXING WITH ANY OTHER WATER.
Compuler Generated Version of EPA Form 3320-1 lRev. 01/06)
Page 1 Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved
.OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 22 PA0025615 PERMIT NUMBER 31'3A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05) 313 TURBINE BLDG DRAIN Internal Outfall No DischargeF---
MONITORING PERIOD MM/DD/YYYY MM/DD/YYYY FROM 11/
01/
2009 TO 11/
30/ 2009 PARAMETER NO.
FREQUENCY SAMPLE QUANTITY OR LOADING QUALITY OR CONCENTRATION NO FRUNCY SAPE VALUE_ _
I_
VALUEEX OF ANALYSIS TYPE VALUE
[VALUE UNITS VALUE
[VALUE
[VALUE
[UNITS__
pH 00400 1 0 N/A N/A N/A MEASUREMENT 6.7 N/A 7.2 pH 0
1 /7 GRAB I~4eo 4f~ ~*~.4r~u.~-4o PERMIT DCfi IID~ICRAIMT1
-4y~ttr.t N/A kj lý OKI I
I
,--..~l
&~~*
I I ~ t~/~.kJyuI ~GR~B-.
SAMPLE 1
4 Solids, total suspended M SUMEN N/A N/A N/A N/A 15 23 mg/L 0
1 / 7 GRAB MEASUREMENT 00530 1 0 PERMIT
-*-*N/A I
1,017,/GIA Effluent Gross REQUIREMENT
.0 N/A i
MA G
- ;Ef+
T g/LA Oil & grease SAMPLE N/A N/A N/A N/A 4
8 mg/L 0
1 / 7 GRAB MEASUREMENT m/
005561 0 PERMIT 4
Effluent Gross REQUIREMENT A%,
T MDX mg/L Flow, in conduit or thru treatment plant SAMPLE 0.002 0.002 MGD N/A N/A N/A N/A 1 / 7 EST Flo, n onui o thu retmntplnt MEASUREMENT 50050 1 0 PEMI i*O5e*.1ý Mo.4**
t uI*
4**-,1r 4
.l~'4n44 o
Effluent Gross PQUIREMIT F
1 R
V(.2 Mgal/d N/A k.X WeqI*I*,-;r4-
- EST#t*A,>
NAME/TITLE PRINCIPAL EXECUTIVE OFFICER certy under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or Kevin L. Ostrowski, DIRECTOR OF SITE persons who nanage thesyster,. orthose parsons directly responsible for gathering the 724 682-7773 12/ 22! 2009 information, the information submited is. to the best of my knowledge and belief, true, accurate, O PERATIO NS and complete. I ar aware that there. am significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
SIGN CER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DDIYYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT DISCHARGE FROM OWS #21 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM Page 23 PERMT NUMBER 401 A DISCHARGE NUMBER DMR MAILING ZIP CODE:
150770004 MAJOR (SUBR05)
CHEM.FEED AREA OF AUX BOILERS Internal Outfall No Discharge*]
FROMMONITORING PERIOD FR MM/DDYYYY TO MMIDD/YYYY FO I
11/
011 20091T 11/
30/
2009 NAME[TITLE PRINCIPAL EXECUTIVE OFFICER I etity under penalty of law that this document and all attachments were prepared under myUTELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons wha mo m
genthe system,. orthose persons directly responsible for gathering the 724 682-7773 12/
22! 2009 intformafion. the information submitted is. to the best of my knowledge and belief. true, accurate, OPERATIONS and omplete. Iam aware that there am significant penalties for submitting false information, including the possibility of fine and imprisonment for knooeng violations.
SIGN URE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MMIDDIYYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT CHEMICAL FEED AREA DRAINS PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 24 PERMITTEE NAMEIADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM L PA0025615 PERMIT NUMBER I403A.
DISCHARGE NUMBER DMR MAILING ZIP-CODE:
150770004 MAJOR (SUBR05)
CONDENSATE BLOWDOWN & RIVR WAT Internal Outfall No Discharge F7-X --
F -MONITORING PERIOD FR MM/DD/2YYY0 MM/DD/YYYY FROMI 11/
01/
20091 TO 11/
30/ 2009 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under myTELEPHONE DATE direction or supernision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons who manegehe system or. those persons directly responsible for gathering the 724 682-7773 12/ 22/ 2009 information, the inforrmation submitted is. to the best of my knowledge and belief. true, accurate OPE RATIONS and omptete.
m
.awara that there are significant penalties tor submitting false information, including the possibility of fine and impdsonment for knowing violations SIGNAT ICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MMIDDIYYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING (24 HR. COMP.):
MG/L. (THE LIMIT IS 35 MG/L AS A DAILY MAX.) SAMPLES SHALL BE TAKEN AT MP 403 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 1
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 25 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:.
FIRST ENERGY NUCLEAR OPERATING ADDRESS:.
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 403A PERMIT NUMBR DISCHARGE NUMBER MONITORING PERIOD MM/DD/YYYY 2
T MM/DD/YYYY FOI 11/
01/
2009 TO 1
1/
30/ 2009 DMR MAILING ZIP CODE:
150770004.
MAJOR (SUBR05)
CONDENSATE BLOWDOWN & RIVR WAT Internal Outfall No Discharge JAI NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with ai system designed to assure that qualified personnel propedy gather and nevluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons wo managethe system or. those persons directly responsibleforgathering the 724 682-7773 12/ 22/ 2009 information, the formation submitted is. to the best of my knowledge and belief, true. accurate.
OPERATIONS and complete. I fi..rse. that there.e. significant penalties for submitting false rnlormation, Including the possibility of fine and imprisonrent for knowing violations.
SIGN URE OF PRINCIPAL EXECUTIVE OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MM/DD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
HYDRAZINE AND AMMONIA MONITORING TO APPLY DURING PERIODS OF WET LAYUP. REPORT THE DAILY MAXIMUM FOR BETZ DT-1 WHEN DISCHARGING (24 HR. COMP.):
MG/L. (THE LIMIT IS 35 MG/L AS A DAILY MAX.) SAMPLES SHALL BE TAKEN AT MP 403 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01/06)
Page 2
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
Page 26 NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 413A PERMIT NUMBER DISCHARGE NUMBER MO7777 NITORING PERIOD IR MM/DD/YY I
MM/DD/YYYY FO I
111 01/
209 TO 1 11/
30/
2009 DMR MAILING ZIP CODE:.150770004 MAJOR (SUBR05)
BULK FUEL STORAGE DRAIN Internal Outfall No Discharge fJAI PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS pH 00400 1 0 Effluent Gross N/A N/A N/A N/A pH MEASUREMENT I
~i.4------4 I~,-4----m----------,,nnB~.~.
~
I-
~
4 PERMIT
- i5n0**.
REQUIREMENT N/A
~Week 1,
-d 2
Solids, total suspended SAMPLE N/A N/A N/A mg/L MEASUREMENT 00530 1 0 PERMIT
-N/A 100,-'.,
Effluent Gross REQUIREMENT DrC.G`DAIDY1MX* mg/L Wkro Oil & grease SAMPLE N/A N/A N/A N/A mg/L MEASUREMENT N/A 00556 1 0 PERMIT
- zO0s, e.*,
i1 tkc-"2 Effluent Gross REQUIREMENT V
A mgNA.
nh--,
.L'R SAMPLEMGN/
Flow, in conduit or thru treatment plant MEASUREMENT MGD N/A 50050 1 0 PERMIT P"i )
~~~l~
i~R?.Mori
~
~
.o~*ETM N/
.Weeký4 1
rr Effluent Gross
[REQUIREMENT Mi AVC~,
IMgaI/d ii&i T~
/
NAMEfTITLE PRINCIPAL EXECUTIVE OFFICER I certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance With a system designed to assure that qualified personnel TE properly gather and evaluate the information submitted. Based on my inquiry of the person or Raymond A. Lieb, DIRECTOR OF SITE persons whr ena..gethe system or. those persoes directly responsible for gathering the 724 682-7773 12/ 22/ 2009 information, the information submitted is, to the best of my knowledge and belief, tnue. accurate, OPERATIONS and complete. l am aware that there Br.. ignificant penafines fto subritting false information, including the possibility of fine and imprisonment for knowing violations.
SIGN OFFICER OR TYPED OR PRINTED AUTHORIZED AGENT AREA Code NUMBER MMIDD/YYYY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT DISCHARGE FROM OWS #24 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page I
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
Form Approved OMB No. 2040-0004 Page 27 PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)
NAME:
FIRST ENERGY NUCLEAR OPERATING ADDRESS:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 FACILITY:
BEAVER VALLEY POWER STATION LOCATION:
PA ROUTE 168 SHIPPINGPORT, PA 150770004 ATTN: DONALD J SALERA/MGR ENV & CHEM PA0025615 PERMIT NUMBER A501A DISCHARGE NUMBER DMR MAILINGZIP CODE:
MAJOR (SUBR05) 150770004
ý MONITORING PERIOD FR MM/DD/YY 2 MM/DDLYYYY FROMI Ill1 01/1 00 TO 1 11/
30/ 2009 UNIT 1 GENRTR BLWDWN FILT BW Internal Outfall No Discharge[*
QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
FREQUENCY SAMPLE PARAMETER EX OF ANALYSIS TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE Solids, total suspended M A M E t.,
MEASUREMENT 00530 1 0 PERMIT
~ov*ov
~
~
- ee7-~,
3/40Y
~rL4-L Effluent Gross REQUIREMENT
,MA.VGIi BY m /L Flow, in conduit or thru treatment plant SAMPLE MEASUREMENT 50050 1 0 PERMIT RR q
" t Effluent Gross REQUIREMENT 5t,11 M1WS DIL X
MgalldL---
ts>_____
COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
SAMPLES SHALL BE TAKEN AT INTERNAL MP 501 PRIOR TO MIXING WITH ANY OTHER WATER.
Computer Generated Version of EPA Form 3320-1 (Rev. 01106)
Page 1