Comprehensive Engineering Team Inspection (CETI) Inspection Report 05000483/2023011
ML23158A092
Person / Time
Site: Callaway Ameren icon.png
Issue date: 06/15/2023
From: Vincent Gaddy
NRC/RGN-IV/DORS/EB1
To: Diya F
Ameren Missouri
References
IR 2023011
Download: ML23158A092 (1)


Text

June 15, 2023

SUBJECT:

CALLAWAY PLANT - COMPREHENSIVE ENGINEERING TEAM INSPECTION (CETI) INSPECTION REPORT 05000483/2023011

Dear Fadi Diya:

On May 25, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Callaway Plant and discussed the results of this inspection with Brent Jungmann, Senior Director, Nuclear Engineering, and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Vincent G. Gaddy, Chief Engineering Branch 1 Division of Operating Reactor Safety Docket No. 05000483 License No. NPF-30

Enclosure:

As stated

Inspection Report

Docket Number:

05000483

License Number:

NPF-30

Report Number:

05000483/2023011

Enterprise Identifier:

I-2023-011-0006

Licensee:

Ameren Missouri

Facility:

Callaway Plant

Location:

Steedman, MO

Inspection Dates:

May 08, 2023 to May 25, 2023

Inspectors:

J. Braisted, Senior Reactor Inspector

D. Bryen, Reactor Inspector

W. Cullum, Senior Reactor Inspector

C. Franklin, Reactor Inspector

N. Okonkwo, Reactor Inspector

D. Reinert, Senior Reactor Inspector

F. Thomas, Reactor Inspector

C. Young, Senior Reactor Analyst

Approved By:

Vincent G. Gaddy, Chief

Engineering Branch 1

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a comprehensive engineering team inspection (CETI) inspection at Callaway Plant, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

===71111.21M - Comprehensive Engineering Team Inspection The inspectors evaluated the following components and listed applicable attributes, permanent modifications, 10 CFR 50.59 evaluations/screens, and operating experience samples:

Structures, Systems, and Components (SSCs) (IP section 03.01)===

(1) CGD02A, Cooling Tower Electrical Room Supply Fan A

Compliance with the updated final safety analysis report (UFSAR), technical specifications (TS), and TS bases

Component modifications and associated evaluations

Design calculations including fan motor minimum voltage, control logic, and heat transfer capacity/heat balance

Visual inspection of fan, dampers, and instruments during walkdown

Vendor and design requirements

Applicable operating experience relevant to sample

(2) EFHV0066, Essential Service Water Cooling Tower Train B Bypass Valve

Design basis documents

System level procedures

Visual inspection of component during walkdown

System calculations

Logic for valve operation

Corrective action program documents

Preventative maintenance tasks and procedures

(3) NB0113, Feeder Breaker to NG01 Control Building Load Center

Compliance with the UFSAR, TS, and TS bases

Design calculations including voltage analysis and short circuit calculations

Visual inspection of equipment and surrounding area

Electrical drawings

Component maintenance history and corrective action program documents

Procedures for circuit breaker inspection, maintenance, and testing

(4) NG01B, A Train 480 VAC Auxiliary Building Motor Control Center

Compliance with the UFSAR, TS, and TS bases

Design calculations including voltage analysis and short circuit calculations

Visual inspection of equipment and surrounding area

Vendor and design requirements

Thermography procedure and results

(5) NK01, 125 VDC Distribution Panel Class IE Group 1

Compliance with UFSAR, TS, and TS bases and plant procedures

Visual inspection of charger and associated system during walkdown

Environmental conditions of equipment

Surveillance procedure, testing, operations and maintenance records

Protection setting and coordination study

Design basis document

Vendor manual for conformance with manufacturer instructions for installation and maintenance

Preventive maintenance and periodic verification testing and post-test analyses

Schematic and wiring drawings

System health report

Corrective action program documents

(6) NK21, 125 VDC Vital Battery Charger 1

Compliance with UFSAR, TS, and TS bases and plant procedures

Visual inspection of charger and associated system during walkdown

Environmental conditions of equipment

Design basis document

Preventive maintenance and periodic verification testing and post-test analyses

Surveillance procedure, testing, operations and maintenance records

Vendor manual for conformance with manufacturer instructions for installation and maintenance

Schematic and wiring drawings reviews

Corrective action program documents

Thermography inspection results of equipment internals

System health report

Protective settings and coordination study

Load test data study of batteries

(7) PEF01A, Essential Service Water Pump A

Design basis documents

System level procedures

Visual inspection of component during walkdown

System calculations

Water hammer analysis Thermal-hydraulic ultimate heat sink analysis

Preventative maintenance tasks and procedures

(8) SGL10A, Residual Heat Removal Room Cooler A

Heat exchanger testing procedures and performance history to assure consistency with vendor and industry recommendations

Room cooler maintenance history to verify the monitoring of potential degradation

Design calculations including required heat capacity, maximum tube plugging limits, and limiting flows and temperature inputs

Corrective action program documents

(9) TEG01A, Component Cooling Water Surge Tank A

Compliance with the UFSAR, TS, and TS bases

Calibration procedures and acceptance criteria calculations for level instrumentation

Component modifications and associated evaluations

Design calculations including minimum usable safety related inventory and tank level setpoints

Visual inspection of tank, valves, and instruments during walkdown

Review of vendor and design requirements

Evaluation of applicable operating experience relevant to sample

(10) XNG01, Transformer Load Center NG01 Load Center

Thermography procedure and results

Voltage analysis and short circuit calculations

Visual inspection during equipment walkdown

Review of vendor manual and plant design drawings

Modifications (IP section 03.02) (5 Samples)

(1) MP 18-0045, Approve Changes to NK Battery Connection System Required for RF23
(2) MP 19-0002, Thermocouple Core Cooling Monitor Replacement
(3) MP 19-0012, Setpoint Re-Adjustment (Lower Level) For Control Building Sump
(4) MP 19-0018, Ultimate Heat Sink Cooling Tower Return to Ultimate Heat Sink Pond
(5) RFR 170223, Gas Void in Containment Spray Pump Suction from Emergency Recirculation Sump 10 CFR 50.59 Evaluations/Screening (IP section 03.03) (20 Samples)
(1) CA2511-00892, MP 13-0001, Replace Essential Service Water Supply Fans CGD01A&B
(2) CA2511-00936, MP 13-0037, Polar Crane Bridge and Trolley Motor Controls Upgrade
(3) CA2511-01196, MP 19-0002, Thermocouple Core Cooling Monitor Replacement
(4) CA2511-01221, MP 19-0085, Cooling Tower Basin Level Indication Phase 2
(5) CA2511-01266, MP 19-0124, Replace KJV0820A/B, Diesel Generator Auxiliary Lube Oil Pump Pressure Relief Valves
(6) CA2511-01267, MP 20-0006, UHS Cooling Tower Fan Motor Circuits Relay Replacement
(7) CA2511-01271, MP 20-0015, XMB01 Exciter Transformer Replacement
(8) CA2511-01272, MP-19-0018, Ultimate Heat Sink Cooling Tower Return to Ultimate Heat Sink Pond
(9) CA2511-01318, MP 21-0009, Improve the Ground Fault Relaying on the C Phase of MA01
(10) CA2511-01344, MP 21-0001, Eliminate the Main Feedwater Regulating Valve Single Point Vulnerability and Improve Reliability
(11) CA2511-01363, MP 21-0020, Replace Batteries PK11 and PK12
(12) CA2511/TABLE 8-8B, Maximum Allowable Number of Fuel Assemblies Offloaded to the Spent Fuel Pool vs. Time after Shutdown Refuel Outage 26 and Spent Fuel Pool Water Temperature Limit for Fuel Handling Operations
(13) CA2512-00032, MP 19-0088, Atmospheric Steam Dump Valves Environmental Qualification
(14) CA2512-00034, Reduction in Containment Passive Heat Sinks
(15) CA2512-00036, MP 20-0012, Obsolete Transmitter - Vendor Cannot Quote Replacement Without Addition Information
(16) MP 19-0012, Setpoint Re-Adjustment (Lower Level) For Control Building Sump
(17) MP 19-0088, Atmospheric Steam Dump Valves Environmental Qualification
(18) MP 19-0116, Evaluate and Approve Electromagnetic Interference Improvements for New EGS Connectors/Connections
(19) MP 21-0021, RFR 210061, Reconfigure Select Intermediate Range Instruments
(20) MP 22-0018, Replacement of Protective Relay PA0210211F

Operating Experience Samples (IP section 03.04) (3 Samples)

(1) CR 201906202, Part 21 Fisher Information Notice 2019-01, Mechanical Setting of Disk/Stem Taper Pins for Fisher Type 7600, 7700, 7800, 9100, 9200, and 9500 Series Butterfly Valves
(2) CR 202101555, Adverse to Quality Condition Found From Cook Unit 2 Operating Experience Review
(3) CR 202104699, Wolf Creek DBAI Minor Violation of 10CFR50.65(a)(4) For Inadequate Model of the Startup Time of the NSAFWP Risk Value in PRA

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On May 25, 2023, the inspectors presented the comprehensive engineering team inspection (CETI) inspection results to Brent Jungmann, Senior Director, Nuclear Engineering, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

CN-CRA-19-5

Callaway Steam Tunnel GOTHIC Modeling Upgrade

E-B-13

Voltage Analysis

EDP-ZZ-01113

Infrared Thermography Program Guide

EF-45

Acceptance Criteria Used in Essential Service Water Flow

Balance Procedures

GD-342

Cooling Tower Electrical Room Ventilation

GK-05

Short Circuit Calculation

GL-137

SGL10A/B Room Cooler Heat Removal Capabilities

J-UEF03

Instrument Loop Uncertainty Estimate: UHS Cooling Tower

Fan Speed and Bypass Valve Control

M-EF-52

Heat Exchanger Performance Based on Reduced ESW

Temperature and Flow

M-EG-05 ADD 2

NPSH Available to the CCW Pumps with the Surge Tank

Empty

M-GK-370

Post-Accident Battery Room H2 Concentration Levels

001

NAI-2114-001

Evaluation of Gas Accumulation in Callaway Containment

Spray Suction Piping

NAI-2163-001

Callaway Energy Center UHS Thermal Performance

Analysis Using GOTHIC

NB-05

System NB Protective Relay Setpoints

004

NK-05

Class 1E Battery Capacity

010

NK-06

Class 1E DC Power System Fault Tree Model

000

NK-06 ADD 1

Class IE DC Power System Fault Tree Model

10/20/1998

NK-10

NK System DC Voltage Drop

2

NK-10

Attachments C, D, E, F, G, and K for NK-10 Calculation

2

ZZ-214

MOV Voltage Drop Calculation

ZZ-534

Quarter-turn MOV Capability and Margin Calculation

Calculations

ZZ-62

Plant Load Flow Calculation

71111.21M

Corrective Action

Documents

Condition Report

201904041, 201701094, 201901943, 201905148,

201906023, 202203343, 202203419, 201601612,

2002721, 202003059, 202003062, 202004888,

2100215, 202100247, 202101093, 202101766,

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

2200624, 202201540, 202001783, 202100910,

2101555, 202102021, 202102548, 202201363,

2300457, 200701515, 202007410, 201803185,

200408670, 200002868, 200409206, 202000763,

2201665, 200800976, 200901546, 201000245,

201004897, 201706920, 201803958, 201904646,

2005745, 202203112, 202204558, 202204863,

201901616, 201803185, 201802828, 201300761,

200801763, 202303127, 202302551, 202300381,

201806334, 201806919, 201905572, 201906202,

201905708, 202101276, 202103720, 201108964,

200803462, 201203653, 201305408, 202203151

Corrective Action

Documents

Resulting from

Inspection

Condition Report

2303237, 202303240, 202303241, 202303254,

2303269, 202303325, 202303400, 202303497,

2303510, 202303592, 202303596, 202303615,

2303621, 202303622, 202303623, 202303634,

2303643, 202303645, 202303676

10466-M-619.2-

23-01

1UEWOC Fan Curves

04/07/1978

E-009-00023

Metal-Clad Switchgear - Power & Control Circuits Electrical

Diagram - NB0113

E-050-00006

Batteries NK11 & NK14 60 Cell NCN-23S Layout ON-2-S07-

074530-816 Racks

014

E-050-00009

Batteries NK12 & NK13 - 60 Cell NCN-13S Layout ON-2-

S07-07 520-816 Racks

013

E-050-00032

Batteries - NCN & NCX Typical Termination Assemblies

003

E-051-00058

3PH SRC Controller Battery Charger Schematics

2

E-051-00079

Battery Chargers Wiring Diagram

009

E-051-00090

Phase Thyristor Control Class 1E 130V Battery Charger

NK21, NK22, NK23, NK24, NK25

011

E-21005(Q)

List of Loads Supplied by Emergency Diesel Generator.

038

E-21NB01(Q)

Lower Medium Voltage System Class 1E 4.16KV Single Line

Meter and Relay Diagram

Drawings

E-21NG01

Single Line Diagram

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

E-21NK01(Q)

Class IE 125V DC System Meter & Relay Diagram

018

E-23NK10

25 Volt DC Class 1E Power System Schematic

29

E-23NN01

Class 1E Instrument AC Schematic

014

E-U3EF05A(Q)

Schematic Diagram Cooling Tower Inlet Bypass Valve

E-U3GD02

Schematic Diagram ESW Elect. Room Supply Fan

M-105A-00002

Component Cooling Water Surge Tank

M-105A-003-02

Support Leg Cross Bracing Detail

01/04/1978

M-105A-009-02

Support Leg Detail

03/24/1977

M-1184-00015

Crosby Pressure Relief Valves

M-22EG01

P&ID Component Cooling Water System

M-22KJ03

P&ID Standby Diesel Generator "A" Lube Oil System

M-22KJ06

P&ID Standby Diesel Generator "B" Lube Oil System

M-619.2-00144

Fan Assembly drawing Buffalo Forge Co. Fan 330 BL ARR

9l Class 1

M-U2GD01

P&ID ESW Pumphouse & UHS Elec. Rm. HVAC

M-UG082

UHS Cooling Tower Arrangement

EC-46

Fuel Cycle 26 Decay Heat Load Calculation

MP 13-0037

Polar Crane Bridge and Trolley Motor Controls Upgrade

2

MP 19-0002

Thermocouple Core Cooling Monitor Replacement

MP 19-0018

UHS Cooling Tower Return to UHS Pond

MP 19-0085

Cooling Tower Basin Level Indication Phase 2

MP 19-0088

Atmospheric Steam Dump Valves Environmental

Qualification

003

MP 19-0116

Electromagnetic Interference Improvements for New EGS

Connectors/Connections

001

MP 19-0124

Replace KJV0820A/B, DG Aux Lube Oil Pump Pressure

Relief Valves

Engineering

Changes

MP 21-0001

Eliminate the Main Feedwater Regulating Valve Single Point

Vulnerability and Improve Reliability

003

19508715.500

Clean and Inspect Battery Charger NK21

000

19511729 NK21

Thermography Inspection Control Building. EL. 2016

000

2508001.500

Thermography Inspection - Control Building EL. 2016

000

Miscellaneous

ARC-1599

Independent Review of Crosby Engineering Calculation EC-

06/04/2020

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

24, R0

CA2507

Curve Book Evaluation Table 8-8B

CA2510

Screening for MP 08-0010

000

CA2510-01463

Improve the Ground Fault Relaying on the C Phase of MA01

50.59 review CA2510-01463 - MP 21-0009

000

CA2510eB

Screening for MP 18-0045 R001

001

CA2511-01318

50.59 Screen for MP 21-0009

000

CA2511-eB

50.59 Screening for MP 18-0045 Approve changes to NK

battery connection system required for RF23

000

CA2512-00034

Reduction in Containment Passive Heat Sinks

E-009-00319

Instruction Manual for SEL-251D Distribution Relay

000

E-050-00016

IM Batteries and Battery Packs Gould Inc, System: NK

Manual

017

E-27000A

Termination List Notes

033

GEH-262IC

General Electric Installation and Maintenance Instructions

for AV-Line Switchboards

06/01/1973

GEK-7320F

General Electric Instructions for Types AM-4.16-350-2C &

AM-4.16-350-2H Magne Blast Circuit Breaker

2/01/1980

GNB Industrial

Power Letter

March 14, 2012-03-14 letter from Paul Mattaliano of GNB

industrial Power to Nicole Weber of Ameren Missouri -

Callaway Energy Center on NCN Hydrogen Generation

Rates

03/14/2012

HI 2004101

Health Risk and Solution Option Ranking -Thermocouple

Core Cooling Monitor (TCCM) Obsolescence Issues (OBS)

J-2049-00000

Thermocouple Core Cooling Monitor Operations and

Maintenance Manual

J-601B-00074

IM Atmosphere Relief Valve - Masoneilan International

055

LDCN 19-0011

FSAR Markup/ LDCR CR# 201901616

FSAR SP SEC 9.3.3.5 for MP 19-0012,

M-2024-00001

IM Nitrogen Isolation - Velan Engineering Company

000

M-612-00062

IM Air Handling Units (Room Coolers) Carrier Corporation

M-619.2-00136

Instruction Manual for Safety Related Fans

M-924

Specification For Safety Related Fans CGD01A & B /

CGM01A & B

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

M-U0GD

System Description Essential Service Water Pump House

Ventilation System and UHS Cooling Tower Electrical Room

Ventilation System

MP 08-0010

CA2511

50.59 Screening for Setpoint adjustment for Control Building

Sump

001

MP 18-0045

Approve changes to NK battery connection system required

for RF23

003

MP 19-0012

Setpoint re-adjustment (lower level) for Control Building

Sump

001

MP 21-0009

Improve the Ground Fault Relaying on the C Phase of MA01

2

MP 21-0020

RFR 200020 - Replace Batteries PK11 & PK12

001

N/A

SEL-351A, -1 Relay Distribution Protection System

Instruction Manual

09/08/2019

NG-22

NK21CB1 Feeder Breaker Application Sheet

001

OTA-RK-00024

Addendum 94F

Miscellaneous Sumps Level High

005

RFR

AK Correction Factors on Room Coolers

B

RFR 004371B

Interstep Cable Connector Part Numbers

B

RFR 007519

Eval. NK Battery Interstep Cable material Equiv.

A

RFR 017225A

Material Equiv. for a different Subtier on a GNB lug

A

RFR 020132A

Update E-050 I/M'S Due NK Battery Replacement

A

RFR 170208

Approve Part Number Change for GNB Batteries (NCN and

NCX Series)

000

RFR 170223

Gas Void in CTMT Spray Pump Suction from Emergency

Recirculation Sump

RFR 170223

Gas Void in CTMT Spray Pump Suction from Emergency

Recirculation Sump

RFR 180078

Approve changes to NK battery connection system required

for RF23 and the battery swap out being done during refuel

000

RFR 200135

Retire Installed Hydrogen Analyzers in the NK, PK and

Comm. Corridor Battery Rooms

000

RFR 20115

Evaluate NK Battery Interstep Cable Material Equiv

000

RFR 210110

External Indication of Ventilation Status For Communications

Corridor Battery Room No. 1

000

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

RFR 210112

Evaluate If NK Battery Room Hydrogen Monitors Are

Required

000

RFR 210113

Evaluate if Communications Corridor Radio Room/Battery

Room Hydrogen Monitor Can Be Retired

000

ULDBD-EG-001

Component Cooling Water

ULDBD-GD-001

Essential Service Water Pumphouse and Ultimate Heat Sink

Ventilation Systems

ULDBD-GL-001

Auxiliary Building Ventilation System

ULDBD-NB-001

Lower Medium Voltage (Class 1E 4.16KV)

ULDBD-NG-001

Low Voltage (480V) - Class 1E

APA-ZZ-00143

CFR 50.59 AND 10 CFR 72.48 Reviews

2

APA-ZZ-00320

Work Execution

2

APA-ZZ-00330

Preventive Maintenance Program Administrative Correction

059

APA-ZZ-00395

Significant Operator Response Timing

033

APA-ZZ-00396

Gas Intrusion Program

APA-ZZ-00500

Corrective Action Program

075

APA-ZZ-00604

Requests For Resolution

2

E-017-00397

IM Load Center Unit Substations General Electric Company,

System: NG

28

E-050-00038

Seismic Qualification Report of Cable Clamps

000

E-051-00090

Phase Thyristor Control Class 1E 130V Battery Charger

NK21, NK22, NK23, NK24, NK25

011

E-051B-00002

Instruction Manual for Installation and Operation pf Class 1E

Electrically Operated Manually controlled Transfer Switches,

NK71-Thru NK78

000

E-1

Loss of Reactor or Secondary Coolant

23

E-1052-00017

IM FOR LGSB13 AND LGSB2 Circuit Breakers, Nuclear

Logistics Inc. System: PG

003

E-2

Faulted Steam Generator Isolation

2

E-21013

Installation, Inspection, and Testing Details For Electrical

Equipment and Cable

057

E-25000A

Cable and Raceway Notes, Details, and Tables

055

Procedures

E-3

Steam Generator Tube Rupture

25

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

ECA-0.0

Loss of All AC Power

2

EDP-ZZ-00396

Gas Intrusion Program Implementation

EDP-ZZ-01112

Heat Exchanger Predictive Performance Manual

EDP-ZZ-01113

Infrared Thermography Program Guide

2

EDP-ZZ-01133

Air Operated Valve Program Guide

26

ISF-EG-000L1

CCW Surge TK 'A' Level Channel OP Test

ISP-NF-0001A

LSELS Train A ESW and CCW Pump Start Inhibit Test

ITL-EG-00R09

CCW HX 'A' Inlet Process Rad Monitor Loop Cal

ITL-GD-00T51

LOOP-TMP; UHS Cooling Tower Elec. Rm Sply Fan

(CGD02A) Temp

ITM-ZZ-VT001

Diagnostic Calibration and Testing of Modulating Air

Operated Valves

25

MP 08-0010

Setpoint adjustment for Control Building Sump

001

MPE-NK-QB004

NK CLASS 1E Battery Charger Inspection

013

MPE-ZZ-QS003

Cleaning and Inspection of 120 VAC Distribution Panels,

25 VDC and 250 VDC Switchboards and Miscellaneous

Electrical Panels

014

MPE-ZZ-QS005

General Electric 4.16KV Breaker PM

034

MPE-ZZ-QS006

GE Magne Blast Breaker Overhaul

015

MPE-ZZ-QS008

G.E. 480 VOLT Load Center PM

29

MPM-ZZ-QH001

Inspection and Maintenance of Tornado Dampers

MPM-ZZ-QV009

Fisher Controls Nuclear Carbon Steel Butterfly Valves -

Disassembly Inspection and Reassembly

MPM-ZZ-QW002

Safety-Related Fan Belt Replacement/Tensioning

MPM-ZZ-QW002

Safety-Related Fan Belt Replacement/Tensioning

MSE-NK-QB002

Quarterly Surveillance on NK Quarterly Surveillance on NK

Large Station Batteries

016

MSE-NK-QB011

Inspection and Surveillance of NK11 Battery and Battery

Chargers NK21/NK25

27

MTE-ZZ-QB002

Battery Charger Maintenance, Field Adjustments, and

Troubleshooting

20

MTE-ZZ-QN005

Electrical Scheme Checkout

011

MTM-ZZ-QA002

Limitorque SMB-00 MOV Inspection and Overhaul

20

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

MTT-ZZ-00001

HVAC System Air Balancing

OSP-EJ-P001A

RHR Train A Inservice Test - Group A

OSP-EN-00002

Containment Spray System Venting

OTA-NK-00001,

Addendum 3A

Switchboard Bus Under Voltage

OTN-EG-00001

Component Cooling Water System

OTN-EG-00001

ADDENDUM 1

Transferring Water Between Surge Tanks

OTN-LF-00001

Addendum 9

Control Building Floor/Equipment Sump level High

004

OTO-EG-00001

CCW System Malfunction

ULNRC-05504

Three-Month Response to NRC Generic Letter 2008-

01,"Managing Gas Accumulation In Emergency Core

Cooling, Decay Heat Removal, and Containment Spray

Systems" (TAC NO. MD7806)

04/10/2008

ULNRC-05551

Three-Month Response to NRC Generic Letter 2008-

01,"Managing Gas Accumulation In Emergency Core

Cooling, Decay Heat Removal, and Containment Spray

Systems" (TAC NO. MD7806)

10/13/2008

ULNRC-05590

Three-Month Response to NRC Generic Letter 2008-

01,"Managing Gas Accumulation In Emergency Core

Cooling, Decay Heat Removal, and Containment Spray

Systems" (TAC NO. MD7806)

2/04/2009

ULNRC-06164

Supplemental Response to NRC Generic Letter 2008-

01,"Managing Gas Accumulation In Emergency Core

Cooling, Decay Heat Removal, and Containment Spray

Systems" (TAC NO. MD7806)

2/15/2014

71111.21M

Work Orders

Job

07510763.250, 10507443.250, 10507443.550,

11512464.500, 17004271.550, 20511173, 21502427,

2509934, 22500698, 20000796, 20002095, 13505629.500,

19508715.500, 19509000.500, 18000362.900,

18000363.900, 18000364.505, 18000365.520,

19003551.940, 21001642, 20511648, 14504618, 20509118,

21500183.500, 22001102.350, 22502362, 18512211.500