IR 05000454/2002005

From kanterella
(Redirected from IR 05000455/2002005)
Jump to navigation Jump to search
IR 05000454-02-005, IR 05000455-02-005, on 04/01-06/30/2002, Exelon Generation Company, LLC; Byron Station; Units 1 & 2. Personnel Performance During Non Routine Plant Evolutions and Other Activities
ML022030353
Person / Time
Site: Byron  
Issue date: 07/22/2002
From: Ann Marie Stone
NRC/RGN-III/DRP/RPB3
To: Skolds J
Exelon Generation Co
References
EA-02-053 IR-02-005
Download: ML022030353 (45)


Text

July 22, 2002

SUBJECT:

BYRON STATION, UNITS 1 AND 2 INSPECTION REPORT 50-454/02-05; 50-455/02-05

Dear Mr. Skolds:

On June 30, 2002, the NRC completed an inspection at the Byron Station, Units1 and 2. The enclosed report documents the inspection findings which were discussed on June 28, 2002, with Mr. R. Lopriore and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the inspection results, the inspectors identified a Severity Level IV violation of NRC requirements. Specifically, in July 1998, your staff implemented a change to the Updated Final Safety Analysis Report (UFSAR) that involved an unreviewed safety question and for which prior NRC approval was not obtained per the requirements of 10 CFR 50.59 in effect at the time.

The change involved the elimination of performance requirements for one of two valves associated with precluding a loss of coolant accident following a thermal barrier heat exchanger rupture. The change also substituted operator manual actions in place of remote manual actions previously described in the UFSAR. We also evaluated the change against the current and revised 10 CFR 50.59 requirements. We determined that this issue would have been a violation of the revised 10 CFR 50.59 rule because the change created the possibility for an accident of a different type than previously evaluated in the UFSAR. However, because the violation was non-willful and non-repetitive and because it has been entered into your corrective action program, the NRC is treating this issue as a Non-Cited Violation in accordance with Section VI.A.1 of the NRCs Enforcement Policy.

In addition, one issue of very low risk significance (Green) was self revealed. The issue involved a failure to follow procedures during the Unit 1 plant shutdown for refueling outage B1R11 and was determined to involve a violation of NRC requirements. However, because of its very low safety significance and because it was entered into your corrective action program, the NRC is treating the issue as a Non-Cited Violation in accordance with Section VI.A.1 of the NRCs Enforcement Policy. If you contest the Non-Cited Violation, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN.: Document Control Desk, Washington, DC 20555-0001, with copies to the Regional Administrator, Region III; Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector at the Byron Station.

The NRC has increased security requirements at the Byron Station in response to terrorist acts on September 11, 2001. Although the NRC is not aware of any specific threat against nuclear facilities, the NRC issued an Order and several threat advisories to commercial power reactors to strengthen licensees capabilities and readiness to respond to a potential attack. The NRC continues to monitor overall security controls and will issue temporary instructions in the near future to verify by inspection the licensee's compliance with the Order and current security regulations.

In accordance with 10 CFR 2.790 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

/RA/

Ann Marie Stone, Chief Branch 3 Division of Reactor Projects Docket Nos. 50-454; 50-455 License Nos. NPF-37; NPF-66

Enclosure:

Inspection Report 50-454/02-05; 50-455/02-05 See Attached Distribution

DOCUMENT NAME: G:\\BYRO\\byr2002005 drp.wpd To receive a copy of this document, indicate in the box "C" = Copy without enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RIII N

RIII RIII N

NAME RSkokowski:dtp BClayton (per email)

AMStone DATE 07/22/02 07/22/02 07/22/02 OFFICIAL RECORD COPY

REGION III==

Docket Nos:

50-454; 50-455 License Nos:

NPF-37; NPF-66 Report No:

50-454/02-05; 50-455/02-05 Licensee:

Exelon Generation Company, LLC Facility:

Byron Station, Units 1 and 2 Location:

4450 N. German Church Road Byron, IL 61010 Dates:

April 1 through June 30, 2002 Inspectors:

R. Skokowski, Senior Resident Inspector P. Snyder, Resident Inspector T. Tongue, Project Engineer K. OBrien, Senior Reactor Inspector D. Pelton, Senior Operations Inspector N. Shah, Resident Inspector, Braidwood K. Walton, Reactor Inspector R. Alexander, Radiation Specialist C. Thompson, Illinois Department of Nuclear Safety Approved by:

Ann Marie Stone, Chief Branch 3 Division of Reactor Projects

SUMMARY OF FINDINGS IR 05000454-02-05, IR 05000455-02-05, Exelon Generation Company, LLC; on 04/01-06/30/2002; Byron Station; Units 1 & 2. Personnel performance during non routine plant evolutions and Other Activities.

The baseline inspection was conducted by resident and region-based inspectors. The inspectors identified one Green finding associated with a Non-Cited Violation and one Severity Level IV Non-Cited Violation related to an inadequate 10 CFR 50.59 safety evaluation. The significance of most findings is indicated by their color (Green, White, Yellow, Red) using Inspection Manual Chapter 0609, Significance Determination Process (SDP). The NRCs program for overseeing the safe operation of commercial nuclear power reactors is described at its Reactor Oversight Process website at http://www.nrc.gov/NRR/OVERSIGHT/ASSESS.

Findings for which the SDP does not apply are indicated by No Color or by the severity level of the applicable violation.

A.

Inspector Identified Findings Cornerstone: Barrier Integrity

Green. The inspectors identified (self-revealed) that the licensee failed to follow Byron General Operating Procedure 100-4, Power Descension, during the plant shutdown on March 11, 2002, by not placing the steam dump controls in the steam pressure mode prior to tripping the turbine generator, which resulted in an unanticipated lifting of the steam generator power operated relief valves.

This finding was determined to be of very low safety significance because the unanticipated lifting of the steam generator power operated relief valve did not result in an actual open pathway in the containment. A Non-Cited Violation of Technical Specification 5.4.1.a, for the failure to follow the procedure was identified.

(Section 1R14)

Cornerstone: Mitigating Systems

NCV. The inspectors identified a Severity Level IV Non-Cited Violation. In July 1998, the licensee implemented a change to the Updated Final Safety Analysis Report (UFSAR) that involved an unreviewed safety question for which prior NRC approval was not obtained per the requirements of 10 CFR 50.59 in effect at the time. Specifically, the licensee changed the UFSAR and failed to adequately evaluate: 1) an elimination of performance requirements for valve 1/2CC-9438 associated with isolation of a loss of coolant accident following a thermal barrier heat exchanger rupture; 2) a decrease in the number, from two to one, of valves in the component cooling water return line that were relied upon to meet the performance requirements of General Design Criteria 44 and 54; and 3) a substitution of operator manual actions for a remote manual valve closure.

This change to the facility, as described in the UFSAR, created the possibility for a new accident not previously evaluated in the UFSAR.

Because the Significance Determination Process (SDP) is not designed to assess the significance of violations that potentially impact or impede the regulatory process, this issue was dispositioned using the traditional enforcement process in accordance with Section IV of the NRC Enforcement Policy. However, the results of the violation, that is, the elimination of performance requirements for one of two valves relied upon to isolate a loss of coolant accident involving a thermal barrier heat exchanger rupture, were assessed using the SDP. The severity level of the violation was then based upon the SDP assessment for the results of the violation. The results of the violation were considered to have more than minor safety significance, in that, the results of the violation had a credible impact on safety by affecting the operability, availability, reliability, or functioning of the component cooling water system. However, the results of the violation did not cause a loss of function of the component cooling water system per the guidance of Generic Letter 91-18, Resolution of Degraded and Non-Conforming Conditions. Therefore, the results of the violation were determined to be of very low safety significance and the violation of 10 CFR 50.59 was classified as a Severity Level IV violation.

Because this non-willful violation was non-repetitive, and was captured in the licensees corrective action program, this issue is being treated as a Non-Cited Violation, consistent with the NRC Enforcement Policy (Section 4OA5).

B.

Licensee Identified Violations No violations of significance were identified.

Report Details Summary of Plant Status As the inspection period began, the licensee was returning Unit 1 to full power following the completion of refueling B1R11. Unit 1 was operated at or near full power until May 18, 2002, when the licensee reduced power to approximately 20 percent for planned repairs to a feedwater regulating valve. Following the repairs the licensee returned Unit 1 to full power on May 21, 2002. The unit was operated at or near full power for the remainder of the inspection period.

The licensee operated Unit 2 at or near full power until June 24, 2002, when the licensee completed an unplanned shutdown of the unit due to steam generator tube leakage in excess of the procedurally established limits. Following the repairs to the steam generator, the licensee returned Unit 2 to full power on June 28, 2002. The unit was operated at or near full power for the remainder of the inspection period.

1.

REACTOR SAFETY Cornerstones: Initiating Events, Mitigating Systems, Barrier Integrity 1R01 Adverse Weather Protection a.

Inspection Scope

The inspectors reviewed the licensees preparations for potential high temperature conditions during the summer season. Specifically, the inspectors performed the following:

Reviewed the Updated Safety Analysis Report (UFSAR), Technical Specifications and other plant documents to identify areas potentially challenged by summer temperatures;

Reviewed applicable licensee procedures and surveillance tests appropriate for monitoring plant conditions during summer weather;

Verified through interviews and record review, that Nuclear Shift Operators were familiar with plant systems potentially affected by high temperatures and that necessary procedural and/or contingency plans were in place; and

Verified that the licensee had performed summer readiness reviews for selected plant systems including the auxiliary feedwater, circulating water, main feedwater, main steam, and electrical (auxiliary power, switch yard, and DC battery) systems.

On June 4, 2002, the inspectors performed a walkdown of the A train of the units 1 and 2 auxiliary feedwater, centrifugal charging, and safety injection pumps; the units 1 and 2 component cooling water pumps; the unit 1 A and B emergency diesel generators; the units 1 and 2 miscellaneous electrical equipment rooms; and the main control room.

The purpose of the walkdown was to verify that the associated cooling and ventilation systems were working properly.

The inspectors also reviewed selected items identified by the licensee, to determine if they had been properly addressed by the licensees corrective action program.

Additionally, the inspectors reviewed the licensees response to the Severe Thunderstorms Warnings on June 3 and 4, 2002.

The documents listed at the end of this report were used by the inspectors to evaluate this area.

b.

Findings

No findings of significance were identified.

1R04 Equipment Alignment (71111.04)

a.

Inspection Scope The inspectors verified the system alignment of the equipment listed below during maintenance activities affecting the availability of associated redundant equipment:

2A Emergency Diesel Generator.

In addition, the inspectors performed a complete system walkdown of the following system:

  • Unit 1 125 Volt Trains A and B DC Battery and Distribution System.

These safety-related systems were selected because they were designed to mitigate the consequences of a potential accident. The inspectors performed a walkdown of the accessible portions of the systems and verified that the system lineup was in accordance with plant operating procedures and applicable system drawings. The inspectors also assessed the material condition of system equipment and verified that identified discrepancies were properly captured in the licensees corrective maintenance program.

The documents listed at the end of this report were also used by the inspectors to evaluate this area.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings No findings of significance were identified.

1R05 Fire Protection (71111.05)

a.

Inspection Scope

The inspectors examined the plant areas listed below to observe conditions related to fire protection:

C Auxiliary Building 383' Elevation (Zones 1D-11, 10-12),

C Auxiliary Building 426' Elevation (Zone 11.6-0),

C Auxiliary Building 346' Elevation (Zone 11.2-0), and

Main Control Room (Zone 2.1-0)

These areas were selected for inspection because risk significant systems, structures and components were located in the areas. The inspectors reviewed applicable portions of the Byron Station Fire Protection Report and assessed the licensees control of transient combustibles and ignition sources, material condition, and operational status of fire barriers and fire protection equipment. The documents listed at the end of this report were also used by the inspectors to evaluate this area.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings No findings of significance were identified.

1R06 Flood Protection Measures (71111.06)

a.

Inspection Scope The inspectors evaluated whether the licensee took appropriate precautions to mitigate the risk from external and internal flooding events. Specifically, the inspectors performed the following:

C Reviewed the UFSAR and other selected design basis documents to identify those areas susceptible to flooding; C

Performed a walkdown of the river screen house, essential service water pump rooms, emergency diesel generator 1A, 1B, 2A and 2B, fuel storage tank rooms, and auxiliary building fuel handling area to evaluate whether appropriate flood protection controls were being maintained; C

Reviewed selected surveillance tests and maintenance records for watertight doors, flood seal openings and selected instrumentation (such as sump alarms)

that help identify flooding events; C

Reviewed selected station operating procedures used to identify and mitigate flooding events; and

C Interviewed selected operating, training, maintenance and engineering staff regarding flood protection controls.

The river screen house, essential service water pump rooms, emergency diesel generator fuel tank rooms, and auxiliary building fuel handling area were selected for the plant walkdown based on their susceptibility to flooding events as described in the licensees design basis documents. The walkdown consisted primarily of observing equipment below the postulated floodline, floor and wall penetrations, flood seal openings and watertight doors, and room drains and sumps.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings No findings of significance were identified.

1R11 Licensed Operator Requalification (71111.11)

a.

Inspection Scope The inspectors assessed licensed operator performance and the training evaluators critique during a licensed operator training session in the Byron Station operations training simulator on May 21, 2002. The inspectors focused on alarm response, command and control of crew activities, communication practices, procedural adherence, and implementation of emergency plan requirements.

b.

Findings No findings of significance were identified.

1R12 Maintenance Rule Implementation (71111.12)

a.

Inspection Scope The inspectors evaluated the licensees implementation of the maintenance rule, 10 CFR 50.65, as it pertained to identified performance problems with the following equipment and systems:

C Maintenance Rule Function PC5 - Primary Containment System Leakage and Post Accident Monitoring Instruments.

During this inspection, the inspectors evaluated the licensees monitoring and trending of performance data, verified that performance criteria were established commensurate with safety, and verified that equipment failures were appropriately evaluated in accordance with the maintenance rule. The documents listed at the end of this report

were also used by the inspectors to evaluate this area. The inspectors interviewed system engineers, operations department personnel and the stations maintenance rule coordinator. The inspectors also attended the licensees maintenance rule expert panel for declaring Function PC5 a maintenance rule a(1) system, requiring performance monitoring.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings No findings of significance were identified.

1R13 Maintenance Risk Assessments and Emergent Work Evaluation (71111.13)

a.

Inspection Scope The inspectors reviewed the licensees evaluation of plant risk for maintenance activities for the following emergent issues:

C Increase Trend in the Unit 2C Steam Generator Tube Leakage; C

Simultaneous 1D Feedwater Flow Oscillations and 1D Reactor Coolant Pump Undervoltage Alarms; and

Decreasing Unit 2 Seal Injection Flow to the 2A and 2D Reactor Coolant Pump Seals.

The inspectors selected these emergent issues because they involved components that were risk significant in the licensees risk analysis, or were considered significant as potential initiating events. During this inspection, the inspectors reviewed the circumstances associated with each issue, and verified that the licensee evaluated the impact of the emergent issues on the planned maintenance activities. In addition, the inspectors reviewed the licensees development and implementation of contingency actions to address risk associated with the emergent issues. The inspectors interviewed operations, engineering, maintenance, and work control department personnel. The documents listed at the end of this report were also used by the inspectors to evaluate this area.

b.

Findings

No findings of significance were identified.

1R14 Personnel Performance During Non-routine Plant Evolutions (71111.14)

a.

Inspection Scope

The inspectors reviewed the licensees response to the following operational events:

Unit 1 Planned Down Power to Allow for the Repair of the 1D Feedwater Regulating Valve (May 18, 2002); and

Unit 2 Unplanned Shutdown due to Excessive Steam Generator Leakage (June 22, 2002).

The inspectors also reviewed Unresolved Item 50-454-02-03-02, pertaining to the procedure review to trip the turbine generator at a higher power than prescribed by the procedure that occurred during the plant shutdown for the Unit 1 refueling outage in March 2002. The inspector reviewed the associated condition reports, apparent cause evaluation and interviewed the operators and plant management associated with the shutdown.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

The documents listed at the end of this report were also used by the inspectors to evaluate this area.

b.

Findings A finding of very low safety significance (Green) was self-revealed. Specifically, the licensee failed to follow Byron General Operating Procedure 100-4, "Power Descension, during the plant shutdown on March 11, 2002, by not placing the steam dump controls in the pressure mode prior to tripping the turbine generator, which resulted in an unanticipated lifting of the steam generator power operated relief valves. The inspectors determined this to be a Non-Cited Violation of Technical Specification 5.4.1.a. No findings of significance were identified with the other activities reviewed.

During the plant shutdown on March 11, 2002, the licensee experienced difficulties with the startup feedwater pump, such that it was not available for use at the point specified in the Byron General Operating Procedure 100-4, Power Descension, Revision 24. Therefore, the operators used the motor driven feedwater pump to complete the shutdown. Although the use of the motor driven feedwater pump in lieu of the startup feedwater pump was described in the power descension procedure, the licensee decided to make an exception to the procedure and trip the turbine generator at 180 Megawatts electric (MWe) instead of the specified 100 MWe. Upon tripping the turbine generator, the steam dump valves did not open as expected. As a result, the steam generator (SG) pressure increased and the SG atmospheric relief valves lifted to provide the necessary plant cooldown.

Based on the review of the apparent cause evaluation and discussions with the operators and station management involved with the shutdown, the inspectors concluded that the operators failed to place the steam dump controls in the pressure

mode prior to tripping the turbine generator as specified by the power descension procedure. This resulted in the unanticipated lifting of the steam generator power operated relief valves.

The inspectors determined that this issue had a credible impact of safety, specifically on the barrier cornerstone because unanticipated lifting of a steam generator power operated relief valve could result in a bypass of the containment if there was a leak in the steam generator tubes. The inspectors evaluated the issue through the significance determination process (SDP) and determined that this issue was of very low safety significance (Green), because there was no indication of steam generator tube leakage and the failure did not result in an actual open pathway in the containment.

Technical Specification 5.4.1.a, states, in part, that written procedures shall be established, implemented, and maintained covering the following activities. The applicable procedures recommended in Regulatory Guide 1.33, Revision 2, Appendix A, February 1978. Appendix A to this Regulatory Guide specifies plant shutdown to hot standby as an example of a general operating procedure. Unit 1 Byron General Operating Procedure 100-4, "Power Descension, Revision 24, Step 20, requires that operators transfer steam dumps to the pressure mode at approximately 15 percent power (185 MWE). Contrary to the above, on March 11, 2002, during the plant shutdown for refueling outage B1R11, the operators failed to transfer steam dumps to pressure mode prior to tripping the turbine generator at approximately 15 percent power (185MWe). Because of the very low safety significance of the item and because the licensee had included this item in the corrective action program (Condition Report 00098784), this violation is being treated as a Non-Cited Violation (50-454-02-05-01).

1R15 Operability Evaluations (71111.15)

a.

Inspection Scope The inspectors evaluated the licensees basis that the issues identified in the following operability evaluations and condition reports did not render the involved equipment inoperable or result in an unrecognized increase in plant risk:

OD 02-007, 2B Diesel Generator Lube Oil Pressure Low,

OD 02-008, 2A Diesel Generator Lube Oil Pressure Low,

OD 02-010, CC9438 Potential Unreviewed Safety Question,

OD 02-011, 2A and 2B Diesel Generator Lube Oil Pressure Low,

Condition Report 00106083, Reactor Coolant Pump Undervoltage Reactor Trip Alert Alarm, and

Several condition reports related to the Unit 2 reactor coolant leak detection system.

The inspectors interviewed operations, engineering, maintenance and regulatory assurance department personnel and reviewed applicable portions of the UFSAR, and Technical Specification. The documents listed at the end of this report were also used by the inspectors to evaluate this area.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings No findings of significance were identified.

1R16 Operator Work-Arounds (71111.16)

a.

Inspection Scope The inspectors performed the semiannual review of the cumulative effects of operator work-arounds (OWA). During this review the inspectors considered the cumulative effects of OWA on the following:

The reliability, availability, and potential for mis-operation of a system;

The ability of operators to respond to plant transients or accidents in a correct and timely manner; and

The potential to increase an initiating event frequency or affect multiple mitigating systems.

Additionally, the inspectors reviewed the following OWA:

OWA 272, Containment Sump Monitor 2RF008.

The inspectors interviewed operating and engineering department personnel and reviewed selected procedures and documents listed at the end of this report. In addition, the inspectors reviewed the licensees changes to address the concerns with containment sump monitor and other associated Unit 2 reactor coolant leak detection system instruments.

b.

Findings No findings of significance were identified.

1R19 Post Maintenance Testing (71111.19)

a.

Inspection Scope The inspectors evaluated the licensees post maintenance testing activities for maintenance conducted on the following equipment:

C 2B Emergency Diesel Generator.

The inspectors selected this post maintenance activity because the system was identified as risk significant in the licensees risk analysis. The inspectors reviewed the scope of the work performed and evaluated the adequacy of the specified post maintenance testing. The inspectors verified that the post maintenance testing was performed in accordance with approved procedures, the procedures stated acceptance criteria, and the acceptance criteria were met. During this inspection activity, the inspectors interviewed maintenance and engineering department personnel and reviewed the completed post maintenance testing documentation. The documents listed at the end of this report were also used by the inspectors to evaluate this area.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings No findings of significance were identified.

1R20 Refueling and Outage Activities (71111.20)

a.

Inspection Scope The inspectors evaluated the licensees conduct of B2F23 forced outage activities to repair the excessive 2C steam generator tube leakage. The inspectors assessed the licensees control of plant configuration and management of shutdown risk, and verified that activities were completed in accordance with the Technical Specifications. The major outage activities evaluated included:

Identification and repair of the 2C Steam Generator tube leak, and

Repair activities associated with the Unit 2 reactor coolant leak detection system.

In addition, the inspectors evaluated portions of the restart activities to verify that requirements of the Technical Specifications and administrative procedure requirements were met prior to changing operational modes or plant configurations.

The inspectors interviewed operations, engineering, work control, radiological protection, and maintenance department personnel and reviewed selected procedures and documents.

The inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for refueling outage issues documented in selected condition reports.

The documents listed at the end of the report were used in the assessment of this area.

b.

Findings

No findings of significance were identified.

1R22 Surveillance Testing (71111.22)

a.

Inspection Scope The inspectors evaluated the surveillance testing activities listed below to verify that the testing demonstrated that the equipment was capable of performing its intended function:

Unit 1 ASME Surveillance Requirements for the 1A Charging Pump, and

Unit 1 ASME Surveillance Requirements for the 1A Containment Spray Pump.

The inspectors selected these surveillance test activities because the system functions were identified as risk significant in the licensees risk assessment and the components were credited as operable in the licensees safety analysis to mitigate the consequences of a potential accident. The inspectors interviewed operations, maintenance, and engineering department personnel; reviewed the completed test documentation; and observed the performance of all or portions of these surveillance testing activities. The documents listed at the end of this report were also used by the inspectors to evaluate this area.

In addition, the inspectors reviewed the issues that the licensee entered into its corrective action program to verify that identified problems were being entered into the program with the appropriate characterization and significance. The inspectors also reviewed the licensees corrective actions for the issues documented in selected condition reports.

b.

Findings

No findings of significance were identified.

Cornerstone: Emergency Preparedness 1EP6 Drill Evaluation (71114.06)

a.

Inspection Scope The inspectors observed the emergency response activities associated with the simulator training completed on May 21, 2002. Specifically, the inspectors verified that the emergency classification and simulated notifications were properly completed, and that the licensee adequately critiqued the training. Additionally, the inspectors determined that the results were properly counted in the Performance Indicators for emergency preparedness.

b.

Findings

No findings of significance were identified.

2.

RADIATION SAFETY Cornerstone: Occupational Radiation Safety (OS)

2OS2 As-Low-As-Is-Reasonably-Achievable (ALARA) Planning and Controls (71121.02)

.1 Post-B1R11 Outage ALARA Reviews a.

Inspection Scope The regional radiation protection inspector reviewed post-B1R11 Outage Radiation Work Permit (RWP)/ALARA reports to compare the results achieved with the dose estimates established in the licensees ALARA plans for these work activities. Included in this review, the inspector assessed the reasons (e.g., failure to adequately plan the activity, failure to provide sufficient work controls, etc.) for any inconsistencies between estimated and actual work activity doses. The inspector also reviewed the Radiation Protection (RP) Lessons Learned database and B1R11 RP-related Condition Reports (CRs) to assess the stations ability to identify repetitive problems, contributing causes, and the extent of conditions, and implement corrective actions intended to achieve lasting results for future refueling outages.

b.

Findings No findings of significance were identified.

Cornerstone: Public Radiation Safety (PS)

2PS2 Radioactive Material Processing and Transportation (71122.02)

.1 Review and Walkdowns of Radioactive Waste Systems a.

Inspection Scope The regional radiation protection inspector reviewed the liquid and solid radioactive waste system description in the UFSAR and the most recent Radiological Effluent Release Report (for calendar year 2000) for information on the types and amounts of radioactive waste (radwaste) generated for disposal.

The inspector performed walkdowns of the liquid and solid radwaste processing systems located in the Radwaste and Auxiliary Buildings to verify that the systems were as described in the UFSAR and the Process Control Program, and to assess the material condition and operability of the systems. The inspector also discussed the current operation of the system with members of the radioactive waste operations crew and the radwaste vendor representative. In the case of abandoned radwaste equipment (i.e.,

volume reduction and radwaste cement/drumming systems), the inspector reviewed the licensees administrative and physical controls implemented to isolate these systems to

verify the equipment would not contribute to an unmonitored radioactive material release path and would not inadvertently affect operating systems.

b.

Findings No findings of significance were identified.

.2 Waste Characterization and Classification a.

Inspection Scope The regional radiation protection inspector reviewed the licensees method and procedures for determining the classification of radioactive waste shipments, including the licensees use of scaling factors to quantify difficult-to-measure radionuclides (e.g., pure alpha or beta emitting radionuclides). Specifically, the inspector reviewed the licensees most recent radio-chemical analysis results for the primary resin, radwaste resin, filters, and dry active waste (DAW) waste streams. The inspector reviewed the report to verify that the licensees scaling factors were accurately determined such that waste shipments were classified in accordance with the requirements contained in 10 CFR Part 61 and the licensees Process Control Program. The inspector also reviewed the licensees process for transferring waste materials into shipping containers to determine if appropriate waste stream mixing and/or sampling procedures were utilized for the purposes of waste classification per 10 CFR 61.55.

The inspector additionally reviewed the licensees procedure employed to ensure that changes in operating parameters, which may result in changes to the waste stream composition, are identified between the annual or biennial scaling factor updates.

b.

Findings No findings of significance were identified.

.3 Shipment Preparation a.

Inspection Scope The regional radiation protection inspector observed shipment preparation for a high integrity container of dewatered bead resin on May 15, 2002, to ensure that the shipping activities were performed in accordance with the requirements of 49 CFR Parts 172 and 173 and those of the low-level burial ground (e.g., Barnwell, SC) site license.

Specifically, the inspector observed the movement of the liner from the storage facility, the final radiological survey, labeling, placarding, vehicle inspections, and the instructions provided to the driver. The inspector observed these activities to assess whether shipping personnel were knowledgeable of the shipping regulations and could adequately demonstrate the skills to accomplish the package preparation with respect to 49 CFR 172 Subpart H and licensee procedure requirements.

b.

Findings

No findings of significance were identified.

.4 Shipping Records a.

Inspection Scope The regional radiation protection inspector reviewed a selection of records for radioactive material shipments completed during calendar years 2001 - 2002 to verify compliance with NRC and Department of Transportation requirements (i.e., 10 CFR Parts 20 and 71; 49 CFR Parts 172 and 173). Specifically, the inspector reviewed the following radioactive materials/waste shipment records:

RMS01-064, Fuel Handling Pump [in a 55 gallon drum] (LSA-II, 09/25/2001)

RWS01-004, Dewatered Bead Resin (Type B, 04/02/2001)

RWS01-007, Dry Active Waste [in a 20' SeaVan] (LSA-II, 06/07/2001)

RWS01-008, Dewatered Bead Resin (LSA-II, 06/20/2001)

RWS01-009, Nozzle Covers [in a 20' SeaVan] (LSA-II, 07/11/2001)

RWS02-001, Dewatered Bead Resin (Type B, 01/20/2002)

RWS02-007, Dewatered Bead Resin (LSA-II, 05/15/2002)

b.

Findings No findings of significance were identified.

.5 Identification and Resolution of Problems a.

Inspection Scope The regional radiation protection inspector reviewed CRs, a Focused Area Self-Assessment, and a Nuclear Oversight Continuous Assessment Report completed since January 2001, which concerned the areas of radioactive waste processing/packaging and radioactive waste/material shipping. The inspector reviewed these documents to assess the licensees ability to identify repetitive problems, contributing causes, the extent of conditions, and implement corrective actions intended to achieve lasting results.

b.

Findings No findings of significance were identified.

4.

OTHER ACTIVITIES (OA)

4OA1 Performance Indicator Verification (71151)

a.

Inspection Scope The resident inspectors verified the following performance indicators for both units:

C Unplanned Scrams per 7000 Critical Hours, C

Scrams with Loss of Normal Heat Removal, and C

Unplanned Power Changes per 7000 Critical Hours.

The inspectors reviewed each of the licensee event reports from April 2001 to March 2002, determined the number of scrams that occurred, evaluated each of the scrams against the performance indicator definitions, and verified the licensees calculation of critical hours for both units. The inspectors also reviewed power history data for both operating units from April 2001 to March 2002, determined the number of power changes greater than 20 percent full power that occurred, and evaluated each of those power changes against the performance indicator definition.

The regional radiation protection inspector reviewed the licensees assessment of its performance indicator (PI) for occupational radiation safety, to determine if performance indicator related data was adequately assessed and reported. Since no reportable events were identified by the licensee for the 3rd and 4th quarters of calendar year 2001 and for the 1st quarter of calendar year 2002, the inspector compared the licensees data with the CR database for these time periods to verify that there were no unaccounted for occurrences in the Occupational Radiation Safety PI as defined by the applicable revision of Nuclear Energy Institute Document 99-02.

The regional radiation protection inspector reviewed the licensees assessment of its PI for public radiation safety by reviewing the dose records related to both liquid and gaseous effluent releases from the station from July 2001 to March 2002, to determine if this data was adequately assessed and reported. Since no reportable events were identified by the licensee for the 3rd and 4th quarters of calendar year 2001 and for the 1st quarter of calendar year 2002, the inspector also compared the licensees data with the CR database for these time periods to verify that there were no unaccounted for occurrences in the Public Radiation Safety PI as defined by the applicable revision of Nuclear Energy Institute Document 99-02.

b.

Findings No findings of significance were identified.

4OA2 Identification and Resolution of Problems (71152)

a.

Inspection Scope The inspectors assessed the licensees apparent cause evaluation (ACE) associated with Condition Report 00098784, B1R11 Shutdown Events and Unexpected Occurrences. In addition to reviewing the ACE, the inspectors also interviewed the operators and station management associated with the event. The documents listed at the end of this report were also used by the inspectors to evaluate this area. The technical issues associated with this event are described in Section 1R14 of this report.

b.

Findings The inspectors determined that the ACE associated with the event was adequate.

However, two significant shortcomings were identified.

First, during the investigation of the event, the licensee failed to interview the Unit 1 Unit Supervisor. The inspectors considered this a major oversight by the licensee since the Unit 1 Unit Supervisor was the main decision maker involved with the decision to trip the turbine generator at a higher power than that specified by the procedure, and his insights were critical in understanding why the steam dump controls were not placed in the pressure mode as prescribed by the procedure.

Second, during the evaluation of the event, the licensee identified that the reactor operators were not afforded the opportunity to weigh in on the decision to trip the turbine at a higher power level than that prescribed by the procedure. Based on the inspectors interviews of the operators involved with the event, the inspectors concluded that although the licensees corrective actions addressed improving the supervisory communications and command and control, no actions were taken to ensure that the management expectations and communications have been understood by the reactor operators.

4OA3 Event Follow-up (71153)

.1 (Closed) Licensee Event Report (LER) 50-454-2002-001-00: Multiple Main Steam Safety Valve (MSSV) Relief Tests Exceeded Required Tolerance Due to Disk to Nozzle Metallic Bonding and Setpoint Drift. On March 7 and 8, 2002, the licensee identified three of 20 MSSVs on Unit 1 had exceeded the Technical Specification limit of 3 percent of lift pressure during surveillance testing. After identifying each test failure, the licensee entered into the appropriate Technical Specification LCO, adjusted the MSSV setpoint, and retested the valve satisfactorily within the TS allowed outage time. The licensee evaluated the impact of the three MSSVs being out of tolerance and concluded that the condition was bounded by the safety analysis report. The inspectors reviewed and concurred with the licensees evaluation. The licensee entered this event into its action tracking system as CR 98531. This event did not constitute a violation of NRC requirements. This LER is closed.

.2 (Closed) LER 50-454-2002-002-00: Two of Three Pressurizer Safety Valve Relief Tests Exceeded Required Tolerance Due to Setpoint Drift. On March 8, 2002, the licensee was notified by a test vendor that two Unit 1 pressurizer safety relief valves (SRVs) had as found lift settings (+1.1 percent and +2.0 percent, respectively) above the

+ 1 percent tolerance allowed by Technical Specification 3.4.10. These valves provide for reactor coolant system overpressure protection and had been removed for testing during the prior Unit 1 refuel outage. The licensee identified no evidence of seat binding or prior maintenance that could have affected the valve performance. The out of tolerance was attributed to setpoint drift combined with the close tolerance between the Technical Specification requirements and the actual response capability of the valve.

Additionally, the licensee determined that even with the out of tolerance, all the acceptance criteria for the UFSAR Chapter 15 Accident Analyses were met. The inspectors reviewed the licensees investigation and had no findings. This event did not constitute a violation of NRC requirements. This LER is closed.

.3 (Closed) Unresolved Item 50-454/455/01-11-02: Failure to perform required testing of the Units 1 and 2 MSIVs. On September 26, 2001, the licensee identified that both units Main Steam Isolation Valves (MSIV) were not tested in Mode 3 as required by Technical Specifications. The licensee requested a Notice of Enforcement Discretion for both units. The NRC approved this NOED on September 27, 2001. The licensee determined the Mode 3 testing requirement was specifically stated in the Improved Technical Specifications, which was implemented in January 01, 1999. Prior to this date, the licensees Technical Specification did not explicitly require that the testing be performed in Mode 3; with testing typically occurring in Modes 4 or 5. The inspectors determined that the root cause was an administrative oversight during the change process to the Improved Technical Specifications. Subsequently the inspectors observed that the Units 1 and 2 MSIVs were successfully tested in Mode 3 on March 25 and June 27, 2002, respectively. The failure to perform the testing in Mode 3 as required in TS 3.7.2.1 constituted a violation of minor significance that is not subject to enforcement actions in accordance with Section IV of the NRCs Enforcement Policy.

This violation was captured in the licensees corrective action program (CR 76845).

4OA5 Other

.1 (Closed) Unresolved Item (URI) 50-454/455-01-03-01 (DRS): Review of the Licensees Change to the Performance Requirements for Valve 1/2CC-9438. The inspectors initiated a Task Interface Agreement which requested additional assistance from the Office of Nuclear Reactor Regulation (NRR).

The inspectors identified a Severity Level IV Non-Cited Violation associated with the licensees failure to obtain prior NRC approval and a licensee amendment, in accordance with 10 CFR 50.59, for a change to the performance requirements for component cooling water valve 1/2CC-9438.

In January 2001, the inspector identified a URI associated with a 10 CFR 50.59 evaluation for a change the licensee made to the UFSAR-specified performance requirements for valve 1/2CC-9438. Specifically, the change removed a UFSAR requirement that the valve would be available for [remote] manual isolation of the component cooling water return flow following a reactor coolant pump thermal barrier heat exchanger rupture and a concurrent failure of the automatic isolation valve. The change also substituted local, manual operator actions, to close the automatic isolation valve if the valve did not automatically close.

The inspectors determined that the licensee initiated the change, in part, due to the results of early 1990s motor operator valve testing. The testing identified that both the automatic (1/2CC-685) and remote-manual (1/2CC-9438) isolation valves, for this line, may not be able to close against the differential pressure expected following a thermal barrier heat exchanger rupture. The licensee implemented a separate plant equipment change, which upgraded the closing capability of the automatic isolation valve (1/2CC-685), to ensure that the automatic isolation valve could perform its intended safety function. However, the licensee did not implement changes to valve 1/2CC-9438 or to the UFSAR-specified valve performance requirements.

In March 2001, the 10 CFR 50.59 requirements were revised. Because the licensee reviewed and approved this change to the UFSAR in July 1998, the NRR staff reviewed the issue against the previous 10 CFR 50.59 requirements. The NRR staff concluded that the licensees actions to remove a UFSAR performance requirement for valve 1/2CC-9438 to be available and capable to respond to a thermal barrier heat exchanger rupture event was an unreviewed safety question. As such, the change required the licensee to obtain prior NRC review and approval. Specifically, the staff determined:

1.

A thermal barrier heat exchanger rupture was considered a credible event for Byron Station. The licensees modification to the performance requirements for valve 1/2CC-9438 introduced a previously unanalyzed, and potentially unisolable, containment-bypassing loss of coolant accident into Byron Stations licensing basis, thereby creating an unreviewed safety question.

2.

The licensee may not rely upon a single valve to isolate a thermal barrier heat exchanger rupture event. Two isolation barriers were required for compliance with the NRCs General Design Criteria 44 and 54, 10 CFR 50.46, and the plant licensing basis.

3.

The NRC had not accepted the radiological consequences for Byron Station resulting from an unisolable, containment-bypassing loss of coolant accident through the component cooling water thermal barrier heat exchanger return line.

This accident was not evaluated by the NRC during the Byron Stations initial licensing because the accident was not considered credible, based upon the requirements to which Byron Station was licensed.

Because violations of 10 CFR 50.59 are considered to be violations that could potentially impede or impact the regulatory process, they are dispositioned using the traditional enforcement process instead of the SDP. Since the SDP is not designed to assess the significance of violations that could potentially impact or impede the regulatory process, the results of a 10 CFR 50.59 violation are assessed using the SDP and the severity level of the violation is then based on this significance determination. In this case, the licensee modified the plant design by eliminating the performance requirements for one of two valves previously relied upon to isolate a loss of coolant accident following a thermal barrier heat exchanger rupture. The licensee formally eliminated the performance requirements in the UFSAR in 1998; however, the licensee was aware of the valves potential inability to meet the UFSAR-specified performance requirements since the early 1990s.

The inspectors concluded that the issue had a credible impact on safety because the licensees elimination of the valve performance requirements resulted in an increased likelihood of a malfunction and could have affected the operability, availability, reliability, or function of the component cooling water system. Because this issue only affected the mitigating systems cornerstone, the inspectors performed a Phase I analysis using the SDP. The inspectors answered yes to Question 1. Specifically, the inspectors determined that the licensees modification of the UFSAR and acceptance of deminished performance requirements for valve 1/2CC-9438 decreased the availability and reliability of the valve and the component cooling water systems ability to function following a loss of coolant accident. However, this issue did not result in a loss of the component cooling water systems function, per Generic Letter 91-18, Resolution of Degraded and Non-Conforming Conditions. Therefore, the issue was determined to be of very low safety significance.

Because this issue was identified prior to March 2001, the issue was evaluated against the previous 10 CFR 50.59 requirements. Specifically, 10 CFR 50.59(a)(1) stated, in part, that the holder of a license authorizing operation of a utilization facility may make changes in the facility, as described in the safety analysis report, without prior Commission approval, unless the proposed change involved an unreviewed safety question. A change in the facility was deemed to involve an unreviewed safety question, per 10 CFR 50.59(a)(2)(ii), if a possibility for an accident or malfunction of a different type than any evaluated previously in the safety analysis report may be created. The licensee was also required to maintain records of changes in the facility to the extent that these changes constitute changes in the facility, as described in the safety analysis report, per 10 CFR 50.59(b)(1). Prior to the licensees 1998 revision, the design basis of the 1/2CC-9438 valve to mitigate a thermal barrier heat exchanger rupture was described in the Byron Station UFSAR, Section 9.2.2.4.4, as follows: A second motor-operated valve in series with [1/2CC-685] is available for [remote] manual isolation of the line, if required.

The inspectors also evaluated the issue against the current 10 CFR 50.59 requirements in accordance with the guidance of Chapter 8 of the Enforcement Policy. The current 10 CFR 50.59 requirements, as outlined in 50.59(c)(1)(ii) and (c)(2)(v), allow, in part, that a licensee may make changes in the facility, as described in the final safety analysis report (as updated), without obtaining a license amendment only if the change does not create a possibility for an accident of a different type than previously evaluated in the final safety analysis report (as updated). Based upon NRRs review of the issue, the inspectors determined that, prior to the licensees July 1998 change to the performance requirements for valve 1/2CC-9438, the NRC did not consider a rupture of the thermal barrier heat exchanger followed by a failure of valves1/2CC-685 and 1/2CC-9438 to close as a credible accident scenario.

Contrary to the above, on July 28, 1998, the licensee failed to perform an adequate written safety evaluation which: 1) provided a bases that the facility change did not involve an unreviewed safety question [old 10 CFR 50.59 requirement], and 2) ensured that a possibility for an accident of a different type than previously evaluated in the UFSAR was not created [new 10 CFR 50.59 requirement]. Specifically, Safety Evaluation 6G-98-0200, Editorial Clarification to Byron/Braidwood UFSAR, Section 9.2.2.4.4, failed to adequately evaluate the licensees: 1) removal of a UFSAR

requirement for valve 1/2CC-9438 to be available and capable to respond to a thermal barrier heat exchanger rupture event; 2) decrease, from two to one, in the number of valves in the component cooling water return line that were relied upon to meet the performance requirements of General Design Criteria 44 and 54; and 3) substitution of operator manual actions for a remote manual valve closure. This change to the facility, as described in the UFSAR, created the possibility for an unanalyzed, unisolable, containment-bypassing loss of coolant accident. Since this type of accident had not been previously evaluated by the Commission as a part of the Byron Stations licensing basis, this change represented an unreviewed safety question that had not received prior Commission approval. The results of the violation were determined to be of very low safety significance; therefore, this violation of 10 CFR 50.59 was classified as a Severity Level IV violation. However, because this non-willful violation was non-repetitive, and was captured in the licensees corrective action program (CR 110460), it is considered a Non-Cited Violation (NCV 50-454/455-02-05-02 (DRP)) consistent with Section VI.A.1 of the NRC Enforcement Policy. This URI is closed.

.2 The inspectors reviewed the Institute of Nuclear Power Operations (INPO) Final Report of the July 2001 Evaluation of the Byron Station issued March 7, 2002.

4OA6 Meetings

.1 Interim Exits The results of the public radiation safety transportation and radioactive waste inspection were presented to Mr. Rich Lopriore and other members of licensee management at the conclusion of the inspection on May 17, 2002. The results of the thermal barrier heat exchanger issue was discussed with Mr. W. Grundmann on July 18, 2002. The inspectors asked the licensee whether any materials examined during the inspection should be considered proprietary. No proprietary information was identified.

.2 Resident Inspector Exit Meeting The inspectors presented the inspection results to Mr. R. Lopriore and other members of licensee management at the conclusion of the inspection on June 28, 2002. The licensee acknowledged the findings presented. The inspectors asked the licensee whether any materials examined during the inspection should be considered proprietary.

No proprietary information was identified.

KEY POINTS OF CONTACT Licensee B. Adams, Engineering B. Altman, Maintenance Manager D. Combs, Site Security Manager D. Drawbaugh, NRC Coordinator D. Goldsmith, Radiation Protection Director B. Grundmann, Regulatory Assurance Manager K. Hansing, Site Nuclear Oversight Manager D. Herrmann, Chemistry Radwaste Specialist D. Hoots, Operations Manager S. Kerr, Chemistry Manager W. Kolo, Work Management Director S. Kovall, Radiation Protection Shipping Specialist S. Kuczynski, Station Manager R. Lopriore, Site Vice President T. Roberts, Engineering Director B. Sambito, Byron Radiation Protection D. Spoerry, Training Manager S. Stimac, Shift Operations Superintendent D. Thompson, Radiation Protection Dose Assessment Health Physicist Nuclear Regulatory Commission K. Karwoski, Senior Level Advisor for Steam Generators and Material Inspection E. Murphy, Senior Materials Engineer A. Stone, Chief, Projects Branch 3, Division of Reactor Projects LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED Opened 50-454-02-05-01 NCV Failure to Follow the Power Descension Procedure 50-454/455-02-05-02 NCV Inadequate 50.59 evaluation related to thermal barrier heat exchangers Closed 50-454-02-05-01 NCV Failure to Follow the Power Descension Procedure 50-454-2002-001-00 LER Multiple Main Steam Safety Valve (MSSV) Relief Tests Exceeded Required Tolerance Due to Disk to Nozzle Metallic Bonding and Setpoint Drift

50-454-2002-002-00 LER Two of Three Pressurizer Safety Valve Relief Tests Exceeded Required Tolerance Due to Setpoint Drift 50-454/455/01-11-02 URI Failure to perform required testing of the Units 1 and 2 MSIVs Discussed None

LIST OF ACRONYMS USED ALARA As-Low-As-Reasonably-Achievable ASME American Society of Mechanical Engineers Aux Auxiliary B1R11 Byron Unit 1's Eleventh Refueling Outage BGP Byron General Operating Procedure BOA Byron Abnormal Operating Procedure BOL Byron Operating Limit Procedure BOP Byron Operating Procedure BOSR Byron Operating Surveillance Requirement Procedure BVSR Byron Technical Surveillance Requirement Procedure CC Component Cooling Water CFR Code of Federal Regulations CR Condition Report CV Chemical and Volume Control System CW Circulating Water DAW Dry Active Waste DC Direct Current DG Diesel Generator DRP Division of Reactor Projects ENV Environmental EPRI Electric Power Research Institute ER Engineering Requirements ESF Engineered Safety Features FASA Focus Area Self-Assessment Report FME Foreign Material Exclusion GPD Gallons Per Day HRSS High Radiation Shutdown Station IN Information Notice IST In-service Testing LCO Limiting Condition for Operation LCOAR Limiting Condition for Operation Action Requirement LER Licensee Event Report LI Level Indication LSA Low Specific Activity MSIV Main Steam Isolation Valves MSSV Main Steam Safety Valves MW Megawatt MWE Megawatt Electrical NCV Non-Cited Violation NEI Nuclear Energy Institute NRC Nuclear Regulatory Commission 0B Unit 0, Train B OD Operability Determination OOS Out-of-Service OP Operating OWA Operator Work-Around PBI Plant Barrier Impairment

PCS Primary Containment System PI Performance Indicator PTLR Pressure-Temperature Limits Report RC Reactor Coolant RCP Reactor Coolant Pump RCS Reactor Coolant System RP Radiation Protection RWP Radiation Work Permit RWST Refueling Water Storage Tank SDP Significance Determination Process SEC Secondary SWGR Switchgear or Switchgear Room TRM Technical Requirements Manual TS Technical Specification U1 Unit 1 U2 Unit 2 UFSAR Updated Final Safety Analysis Report WC Work Control WR Work Request

LIST OF DOCUMENTS REVIEWED 1R01 Adverse Weather Conditions Byron Station River Management Plan 2002 Revision 0 Exelon Generation Extreme Heat Implementation Plan for Byron Summer 2002 Transmission Planning Studies for Increased Ratings at Byron Station March 21, 2000 Action Item List Summer 2002 0B0A ENV-1 Adverse Weather Conditions Unit 0 Revision 100 2B0A ENV-1 Adverse Weather Conditions Unit 2 Revision 3 CR 00087079 Focus Area Self Assessment: Adverse Weather Preparation December 17, 2001 CR 00107759 Expectations for Severe Weather Checks Not Clear May 09, 2002 CR 00110607 Discrepancy Between TRM 3.7.d and UFSAR Table 3.11-2 June 28, 2001 CR 00110499 0/1/2 BOA ENV-1 Entry Due To Severe Thunderstorm Warning June 3, 2002 CR B2001-02150 0B CW Makeup Pump Motor Stator High Temperature Followup Report April 6, 2001 CR B2001-03270 High Temperatures in U2 MSIV Room July 23, 2001 Action Request Identification B2001-02150 0B CW Makeup Pump Motor Stator High Temperature Follow May 9, 2001 Action Request Identification B2001-02999 U1 Operation Liabilities During Hot Weather July 7, 2001 Operating Rounds, Aux-2 (12-Hr)

May 29, 2002 Work Order 00327018 High Temperature Equipment Protection April 2, 2002 Work Order 00446033 Determination of Maximum Allowable Lowdown May 24, 2002 Work Order 00448596 Determination of Maximum Allowable Lowdown June 2, 2002

0BOSR 0.1-0 Unit Common All Modes/All Times Shiftily and Daily Operating Surveillance Data Package Revision 8 June 3, 2002 OP-AA-108-109 Seasonal Readiness Revision 0 LER 2002-002-00 Two of Three Pressurizer Safety Valve Relief Tests Exceeded Required Tolerance Due to Setpoint Drift May 16, 2002 1R04 Equipment Alignment Technical Specifications Updated Final Safety Analysis Report (UFSAR)

Byron Unit 1 Pressure Temperature Limits Report (PTLR)

Revision June 28, 1999 1B0A ENV-1 Adverse Weather Conditions Unit 1 Revision 3 BOP DG-1 Diesel Generator Alignment To Standby Condition Revision 8 BOP DG-11 Diesel Generator Startup Revision 15 BOP DG-12 Diesel Generator Shutdown Revision 15 BOP DC-E1A DC Battery & Distribution System, Unit 1 Train A, Electrical Lineup Revision 1 BOP DC-E1B DC Battery & Distribution System, Unit 1, Electrical Lineup Revision 2 List of Open Work Requests CR 00100059 Possibly Multiple Missed LCOAR Entries March 20, 2002 CR 00103539 Personnel Entered Unit 2 HRSS Panel With Sampling in Progress April 11, 2002 Drawing 125V DC ESF Distribution Center Bus 111 Part 1 Drawing 125V DC ESF Distribution Center Bus 111 Part 2 1R05 Fire Protection Byron Station Pre-Fire Plans Revision 4

Byron Fire Protection Report, Section 2.3.9, Diesel Generator Areas Amendment 13 BGP 1100-3 Plant Barrier Impairment (PBI) Program Revision 17 BGP 1100-3TI Plant Barrier Impairment Permit (PBI No.

1999-483 Revision 4 CR B2001-00165 Excessive Combustible in Storage Cage January 11, 2001 CR B2001-00432 Use of Cable Risers as Storage Areas January 30, 2001 CR B2001-00513 Radiation Protection Cage Contains an Excessive Amount of Combustibles February 2, 2001 CR 00080246 Failed Fire Detector In Zone ID-20 October 25, 2001 CR 00098053 Non-Fire Retardant Wood Pallets In Auxiliary Building March 5, 2002 CR 00104178 Unsecured Carts on 346' Aux Building (NRC Identified)

April 17, 2002 WC-AA-201 Plant Barrier Impairment Permit (PBI No.01-327), (PBI No.01-328), (PBI No.02-027)

Revision 3 1R06 Flood Protection Measures (71111.06)

Byron Station Technical Specifications Byron/Braidwood Stations Updated Final Safety Analysis Report CR 00103324 WR 99090414 Set To Complete Without Work Being done April 11, 2002 CR 00103373 Inconsistency Between UFSAR Sections 3.4.1.1 and 2.4.2.3 April 11, 2002 CR 00109713 Water-Tight Barrier Inspection May 28, 2002 CR 00110551 The Inappropriate Action or Equipment Problem and its Negative Result June 4, 2002 CR B2001-02471 CC Surge Tank Flooding Concerns May 27, 2001 CC-AA-201 Plant Barrier Control Program Revision 3 LSA-AA-126 FASA for NRC IP 71111.06 Flood Protection Measures Revision 0

Assessment of Flooding Protection in Preparation for NRC Flooding Inspection, Byron Station April 12, 2002 Focus Area Self-Assessment Report Review of the Diesel Oil Storage Tank Rooms May 1, 2000 to May 10, 2000 1R12 Maintenance Rule Implementation Technical Requirements Manual Technical Specifications Maintenance Rule-Performance Criteria PC5 Primary Containment System Leakage and Post Accident Monitoring Instruments Byron Station Plant Review Report 01-068 Revision to Technical Specification Bases 3.4.15, RCS Leakage Detection Instrumentation December 26, 2001 CR 00078896 Tech Spec Instruments Affected By Containment Release October 14, 2001 CR 00083725 Unplanned LCOAR Entry For 2LI-PC003 November 22, 2001 CR 00088421 Improvement For 2LI-PC003 Comp. Action Documentation December 29, 2001 CR 00098062 Maintenance Rule: PC5 Enters (a)(1) Due to Repeat Failures March 1, 2002 CR 00098471 LCOAR Entry (2BOL 4.15) Due To 2LI-PC002 March 8, 2002 CR -1-241 Unplanned BOL Entry 2PC002 March 21, 2002 CR 00100961 Unplanned LCOAR Entry 2PC002 March 25, 2002 CR 00102319 Unplanned LCOAR For 2BOL 3.I On 2PC003 April 4, 2002 CR 00102733 Unplanned LCOAR Entry Into 2BOL 3.I For 2PC003 April 7, 2002 CR 00106076 Maintenance Rule: PC4 Enters (a)(1) Status April 26, 2002 WC-AA-11-Complex Troubleshooting Plan, RF008, PC002/3 March 18, 2002

Regulatory Guide 1.45 Reactor Coolant Pressure Boundary Leakage Detection Systems May 1973 ER-AA-310-1005 Maintenance rule (a)(1) Action Plan, Goals, and Monitoring Template, Function PCS Redundant Containment Sump Level Indication May 10, 2002 TRM LCO 3.0.c Failure To Restore 2LI-PC003 Within Required 30 Days Per 2BOL 3.I, Entered Probatively To Avoid Time Pressure. Do Not Expect To Correct This Condition Prior to 30 Days December 5, 2001 1R13 Maintenance Risk Assessments and Emergent Work Evaluation Byron Operating Department Policy 400-47 On-Line Risk/Protected Equipment Revision 2 Unit 2 Byron Abnormal Operating Procedure (2BOA) SEC-8 Steam Generator Tube Leak - Unit 2 Rev. 102 NRC Inspection Manual, Part 9900:

Technical Guidance Steam Generator Tube Primary-to-Secondary Leakage October 11, 2001 NRC Information Notice 91-43 Recent Incidents Involving Rapid Increases in Primary-to-Secondary Leak Rate July 5, 1991 NRC Information Notice 94-43 Determination of Primary-to-Secondary Steam Generator Leak Rate June 10, 1994 Apparent Cause Evaluation Content CV Seal Injection Flow Changes Caused By FME May 31, 2002 BGP 300-9 Steam Generator Tube Leak Rate Determination Revision 20 2BEP-3 Steam Generator Tube Rupture-Unit 2 Revision 100 2BOA RCP-2 Loss of Seal Cooling - Unit 2 Revision 100 BOP MS-11 Operation With Steam Generator Tube Leakage Revision 3 2BOSR 5.5.1-1 RCS Seal Injection Flow Verification Monthly Surveillance-Unit 2 Revision 2

Complex Troubleshooting Unexpected Receipt of TSLB Annunciator and Computer Point Alarms on Bus 159 April 30, 2002 Shift Manager Log April 30, 2002 CR 00105044 Unit 2 RC Filter Plugging By Unknown Contaminants April 23, 2002 CR 00105968 Feed Flow Oscillations Drive Calorimetric Oscillations April 29, 2002 CR 00106083 RCP Bus 159 Undervoltage Reactor Trip Alert Alarm April 30, 2002 CR 00106695 Increase Noted in Unit 2 Primary to Secondary Leak Rate May 2, 2002 CR 00106857 Superceded Standing Order Not Updated in Main Control Room - NRC Identified May 5, 2002 CR 00107072 U-2 Primary to Secondary Leak Greater than 30 GPD May 5, 2002 CR 00107210 Post Seal Injection Filter Change-up Surveillance May 7, 2002 CR 00107294 High D.S. On SI Filters and Seal Injection Flow Problems May 8, 2002 WC 0000337224 000 Potential FME (resin) on the 2A and 2D Reactor Coolant Pump (RCP) Seals and Pump Radial Bearing May 21, 2002 Unit 2 Standing Order Log Number 02-040 2C Steam Generator Tube Leak Mitigation Strategy May 3, 2002 Drawing M-64, Sheet 3A Diagram of Chemical & Volume Control &

Boron Thermal Regeneration Revision AW MA-AA-716-004 Complex Troubleshooting - Decreased Seal Injection Flow to 2A & 2D RCP Seal Revision 0 MA-AA-716-004 Complex Troubleshooting - Increasing RC Filter Revision 0 Contingency Plan For U-2 Seal Injection Issues Shift Manager Log May 8, 2002 Policy No 400-47 Byron Operating Department Policy Statement Revision 2 WC-AA-101 On Line Work Control Process Revision 6

WC-AA-101-1001 Work Screening and Processing Revision 1 WC-AA-101-1002 On Line Scheduling Process Revision 0 1R14 Personnel Performance During Non-routine Plant Evolutions Electric Power Research Institute (EPRI) Test Report No. TR-105872 Safety and Relief Valve Testing and Maintenance Guide August 1996 IN 86-92 Pressurizer Safety Valve Reliability November 4, 1986 IN 88-68 Setpoint Testing of Pressurizer Safety Valves with Filled Loop Seals Using Hydraulic Assist Devices August 22, 1988 IN 89-90 Pressurizer Safety Valve List Setpoint Shift December 28, 1989 IN 89-90, Supplement 1 Pressurizer Safety Valve Setpoint Shift April 3, 1991 IN 91-74 Changes in Pressurizer Safety Valve Setpoint Before Installation November 25, 1991 OP-AA-106-101-1001 Event Response Guidelines Revision 0 OP-AA-106-101 Significant Event Reporting Revision 0 1BGP 100-4 Power Descension Revision 24 BOP HD-2 Heater Drain System Shutdown Revision 5 BOP FW-2a Shutdown of a Unit 1 Turbine Driven Main Feedwater Pump Revision 8 BOP FW-7 Startup of a Motor Driven Feedwater Pump Revision 15 CR 00108684 1B FW pp Shutdown Due to High Vibration May 19, 2002 CR 00109577 Power Up-rate Numbers For MWs Not Updated In BGP May 19, 2002 CR 00109647 1C FW PP Did Not Go To Speed Setter When Pump Tripped May 19, 2002 CR 00112888 Gland Steam Not Aligned to AS Delaying U2 Cooldown June 22, 2002

CR 00112951 2C SG Primary to Secondary Tube Leak Greater Than 75 GPD June 21, 2002 Unit 2 Byron Abnormal Operating Procedure (2BOA) SEC-8 Steam Generator Tube Leak - Unit 2 Rev. 102 Shift Manager Log June 22, 2002 Apparent Cause Evaluation 98784-01 B1R11 Shutdown Events and Unexpected Occurrences March 12, 2002 98784 B1R11 Shutdown Events and Unexpected Occurrences March 12, 2002 98775 Unit 1 Steam Dump Operation Inappropriate Response March 12, 2002 GL 91-18 Information to Licensees Regarding NRC Inspection Manual Section on Resolution of Degraded and Nonconforming Conditions Revision 1 1R15 Operability Evaluations UFSAR Technical Specifications Regulatory Guide 1.45 Reactor Coolant Pressure Boundary Leakage Detection Systems May 1973 Complex Troubleshooting Unexpected Receipt of TSLB Annunciator and Computer Point Alarms on Bus 159 April 30, 2002 Byron Station Plant Review Report 01-068 Revision To Technical Specification Bases 3.4.15, RCS Leakage Detection Instrumentation December 26, 2001 TRM LCO 3.0.c Failure To Restore 2LI-PC003 Within Required 30 Days Per 2BOL 3.I, Entered Probatively To Avoid Time Pressure. Do Not Expect to Correct This Condition Prior To 30 Days December 5, 2001 CR 00078896 Tech Spec Instruments Affected By Containment Release October 14, 2001 CR 00083725 Unplanned LCOAR Entry For 2LI-PC003 November 22, 2001 CR 00088421 Improvement for 2LI-PC003 Comp. Action Documentation December 29, 2001

CR 00097770 Problems With RCS Leakage Detection Systems March 4, 2002 CR 00098471 LCOAR Entry (2BOL 4.15) Due to 2LI-PC002 March 8, 2002 CR 00097770 Apparent Cause Evaluation Content, Problems With The RCS Leakage Detection Systems May 8, 2002 CR 00100221 Seismic Concern With RCS Leak Detection March 20, 2002 CR 00100241 Unplanned BOL Entry 2PC002 March 21, 2002 CR 00100961 Unplanned LCOAR Entry 2PC002 March 25, 2002 CR 00102319 Unplanned LCOAR For 2BOL 3.I on 2PC003 April 4, 2002 CR 00102586 RM-11 Crash Requires MIS Assistance to Restore April 5, 2002 CR 00102558 RM-11 Loop-5 Communications Failure Causing Unexpected LCOAR April 5, 2002 CR 00102733 Unplanned LCOAR Entry Into 2BOL 3.I For 2PC003 April 7, 2002 CR 00103251 Observations/Issues Associated With Unit 2 RF Sump Inst.

April 10, 2002 CR 00103308 Unjustified Assumption Regarding RCS Leakage April 11, 2002 CR 00103605 Unplanned LCOAR Entry For 1PR11J April 12, 2002 CR 00104200 Maintenance Rule: RF1 Enters (a)(1)

Status April 12, 2002 CR 00104799 Unplanned LCOAR Entries to RM-11 Loss of Communication April 22, 2002 CR 00104996 Unplanned LCOAR Entries On RM-11 Radiation Monitors April 23, 2002 CR 00105565 Unplanned LCOAR Entry on Rad Monitors For Loss of Comm.

April 26, 2002 CR 00106083 BGP Bus 159 Undervoltage Reactor Trip Alert Alarm April 30, 2002 CR00110759 2LI-PC002 is showing Early Signs of Degradation June 5, 2002

CR 00108431 2B DG Turbocharger Lube Oil Pressure Alarm May 16, 2002 CR 00109147 Received 2B Diesel Generator Valves From Com Ed Investment May 22, 2002 CR 00109297 2B DG Low Oil Pressure May 23, 2002 CR 00110030 Lower Than Expected Lube Oil Pressure For 2A DG May 30, 2002 CR 00110840 Possible Inoperability of 2LI-PC002 But U-2 Unaware June 6, 2002 CR 00111315 2LI-PC002 Continued Degradation Following 6/7/02 BURP June 10, 2002 CR 00111712 Lower Than Expected Oil Pressure During 2B DG Surveillance June 12, 2002 CR 00112480 2LI-PC002 is Showing Signs of Degradation June 19, 2002 Shift Manager Log March 8, 2002 Shift Manager Log April 30, 2002 Supporting Operating Documentation 2A DG Lube Oil Pressure Low Revision 1 Drawing 6E-1-4017D Relaying and Metering Diagram 6900V SWGR Bus 159 Revision H Drawing 6E-1-4030AP13 Schematic Diagram 6.9KV SWGR. Bus 159 Undervoltage and Under frequency Relays Revision P Westinghouse Drawing 1046F57 A Schematic Diagram Universal Board Drawing 6E-1-4030EF12 Schematic Diagram Annunciator and Computer Demultiplexer, Part 1 Revision H Drawing 6E-1-4030EF28 Byron Unit 1 Schematic Diagram Reactor Protection - Reactor Coolant Pump Under frequency and Undervoltage and Overpower and Overtemperature Trips Revision G Drawing 6E-1-4030EF48 Schematic Diagram Demultiplexer Cont.

Cards 1PA17J - Part 1 Revision B Drawing 6E-1-4030EF72 Byron Unit 1 Schematic Diagram Reactor Prot. Reactor Coolant Pump Under frequency and Undervoltage and Over Power and Over Temperature Trips Revision F

Drawing 6E-1-4030AN094 Schematic Diagram Demultiplexer Control Cabinet 1PA17J, Part 4 Revision H WC-AA-110 Complex Troubleshooting Plan, RF008, PC002/3 March 18, 2002 2BOSR RF-1 Unit 2 Containment Floor Drain Monitoring System Non Routine Surveillance Revision 5 O.D. #02-007 2B DG Lube Oil Pressure Low May 17, 2002 O.D. #02-008 2A DG Lube Oil Pressure Low June 3, 2002 O.D. # 02-010 CC9438 Potential Unreviewed Safety Question June 14, 2002 O.D. #02-011 2A & 2B DG Lube Oil Pressure Low June 13, 2002 Unit 2 Standing Order 02-042 Engineering Evaluation Supporting Operability of 2LT-PC002 After 5/10/02 May 13, 2002 Engineering Change WC Evaluation Supporting Operability of 2LT-PC003 (Containment Floor Drain Sump Level Transmitter) As An RCS Leak Detection Instrument Per Requirements of TS 3.4.15 March 15, 2002 Engineering Change Evaluation Supporting Operability of 2LT-PC003 For Meeting Post Accident Monitoring (PAM) Instrumentation Requirements of TS Manual (TRM)

Section 3.3.1 March 19, 2002 Engineering Change Evaluation Supporting Operability of the 2LT-PC002 and 2LT-PC003 Containment Floor Drain Sump Level Transmitters for RCS Leakage Detection and Post Accident Monitoring March 21, 2002 GL 91-18 Resolution of Degraded and Nonconforming Conditions October 23, 1997 Info Notice 97-78 Crediting of Operator Actions in Place of Automatic Actions October 8, 1997 Operability Determination 02-010 CC9438 Potential Unreviewed Safety Question June 14, 2002 1104060 NRC Response to Unresolved Item 50-454/455-01-03-01 May 31, 2002

Memorandum Response to Task Interface Agreement 2001-009 Regarding Potential Unisolable Reactor Coolant Leak Outside Containment at the Byron Station (TAC NOS. MB2907 and MB2908)

May 24, 2002 1R16 Operator Workarounds OP-AA-101-303 Operator Work-Arounds Program Revision 0 Fourth Quarter 2001 Operator Work Around Aggregate Impact Assessment March 6, 2002 Operator Work Arounds April 10, 2002 OWA 272 Containment Sump Monitor 2RF008 May 1, 2002 Operator Work Around Committee Meeting Agenda April 4, 2002 1R19 Post Maintenance Testing 2BOSR 8.1.2-2 Unit Two 2B Diesel Generator Operability Surveillance Revision 10 BOP DG-3 Filling the Diesel Generator Jacket Water System Revision 9 BOP DG-4 Draining the Diesel Generator Jacket Water System Revision 7 CR 00077039 Apparent Cause Evaluation - 2A SI Pump Circuit Breaker Damaged April 8, 2002 CR 00077039 2A SI Pp Circuit Breaker Damaged September 30, 2001 CR 00076679 2VA04CB Failed to Start on 2A SI Pump Start September 27, 2001 1R20 Refueling and Outage Activities CR 00112862 Unit 2 Shutdown Due to 2C SG Tube Leak June 22, 2002 CR 00113088 Bubbler Tube Location for RF008 & WEIR Box Cover (NRC Identified)

June 24, 2002 Exelon Memo Tube Plugging List for Steam Generator C-B2F23 June 25, 2002

2C Steam Generator IN SITU Pressure Testing June 25, 2002 OU-AP-104 Shutdown Safety Management Program Byron/Braidwood Annex Revision 4 BOP FW-22 Pressurizing the Steam Generators with Nitrogen to Identify Primary to Secondary Tube Leaks June 22, 2002 1R22 Surveillance Testing Technical Specifications Updated Final Safety Analysis Report Memo 300.14 Byron Site Policy Memo (Subject: Climbing)

Revision 0 BOP CS-5 Containment Spray System Recirculation To The RWST Revision 7 BOP CV-29 Operation of the CV Pump on Recirculation Revision 1 1BOSR 3.2.8-644A Unit 1 Train A Automatic Containment Spray

- K644 Revision 0 BVP 200-1T3 Technical Review of Pump Performance Parameters May 15, 1989 1BVSR 5.2.4-5 Unit 1 Train A ASME Surveillance Requirements For Centrifugal Charging Pump 1A and Chemical and Volume Control System Valve Stroke Test Revision 6 1BVSR 6.6.4-1 Unit 1 ASME Surveillance Requirements For The 1A Containment Spray Pump Revision 3 CR00100536 Incorrect Recorder Connections During 1B DG Testing March 18, 2002 CR 00103267 Chart Recorder for Quarterly DG Start Not Properly Set-up April 10, 2002 CR 00080014 2B DG Inoperable, LCOAR, Slow Start Time October 23, 2001 CR 00080017 EDG Fast Starts Not Timed as Required By TS October 23, 2001 CR 00182931 Incorrectly Installed Test Equipment Caused Short Circuit on 2A DG Circuit.

November 14, 2001

Root Cause Review A Miss Wired Chart Recorder Hooked up to 2A DG Shorts Out the Voltage Regulator Causing the 2A DG To Be Inoperable January 8, 2002 Root Cause Review Procedure Revision Errors Result in Emergency Diesel Generator Fast Start Not Timed as Required by TS and Operating Complications March 4, 2002 Drawing M-64, Sheet

  1. 3A Diagram of Chemical and Volume Control and Boron Thermal Regeneration Revision AW Drawing M-64, Sheet
  1. 4A Diagram of Chemical and Volume Control and Boron Thermal Regeneration Revision K Drawing M-64, Sheet
  1. 4B Diagram of Chemical and Volume Control Boron Thermal Regeneration Revision 3 ER-AA-321 IST Pump Evaluation Form, Report 01-006, Pump EPN 1CV01PA March 16, 2001 WO 00406445 ASME Surveillance Requirements For CV Pump April 29, 2002 2PS2 Radioactive Material Processing and Transportation Byron/Braidwood Updated/Final Safety Analysis Report, Chapter 11 Revision 8 Focus Area Self-Assessment: Radioactive Material shipping April 15 - 26, 2002 BRP 5600-13 Trending for Shifts in Scaling Factors and Waste Stream Sampling Revision 4 CC-AA-109 Interim Abandoned Equipment Identification, Evaluation and Control Revision 1 CR B2001-01821 Shipment of Smoke Detectors to LaSalle Station without Appropriate Rad.

April 13, 2001 CR B2001-02827 Issue with Resin Beads Outside Burial Container at Barnwell June 22, 2001 CR 00079523 Resin Identified on Radwaste HIC Intended for Off-Site Disposal October 17, 2001 CR 00085686 Radwaste Vendor Hoses Plugged with Spent Resin December 7, 2001

CR 00105179 AB Condensate Demin Resin Too High in Activity to Ship April 24, 2002 CR 00107996 Radwaste Shipping Concerns May 10, 2002 CR 00108212 Tape Found on Outside of Radwaste Burial Container May 15, 2002 CR 001083371 Items Identified During NRC Walkdown May 14, 2002 CR 001085561 Resin Beads Outside Burial Container at Barnwell May 17, 2002 NOA-BY-01-3Q Nuclear Oversight Continuous Assessment Report October 16, 2001 Radioactive Material Shipment 01-064 Fuel Handling Pump (Shipped to Braidwood Station, IL)

September 25, 2002 Radioactive Waste Shipment 01-004 Dewatered Bead Resin (Shipped to Barnwell, SC)

April 2, 2001 Radioactive Waste Shipment 01-007 Dry Active Waste (Shipped to US Ecology in Oak Ridge, TN)

June 7, 2001 Radioactive Waste Shipment 01-008 Dewatered Bead Resin (Shipped to Barnwell, SC)

June 20, 2001 Radioactive Waste Shipment 01-009 Nozzle Covers (Shipped to GTS Duratek in Oak Ridge, TN)

July 11, 2001 Radioactive Waste Shipment 02-001 Dewatered Bead Resin (Shipped to Barnwell, SC)

January 20, 2002 Radioactive Waste Shipment 02-007 Dewatered Bead Resin (Shipped to Barnwell, SC)

May 15, 2002 RP-AA-600 Radioactive Material/Waste Shipments Revision 5 RP-AA-600-1003 Radioactive Waste Shipments to Barnwell and the Defense Consolidation Facility (DCF)

Revision 0 RP-AA-601 Surveying Radioactive Material Shipments Revision 2 RW-AA-1003 Process Control Program for Radioactive Wastes Revision 2 4OA1 Performance Indicator Verification First Quarter 2002 PI Data Submittal April 18, 2002

NEI [Nuclear Energy Institute] 99-02 Regulatory Assessment Performance Indicator Guideline Revision 2 Common Cause Analysis NEI NRC Performance Indicator for Unplanned Power Changes Exhibits Negative Trend December 5, 2001 CR B2001-02983 NEI/NRC PI-Unplanned Scrams-Has a Negative Trend July 6, 2001 CR B2001-03100 Data Error For NEI/NRC Unplanned Scrams PI July 16, 2001 CR 00074907 1FW510 Positioner Washer Missing Causes Derating to 25% Power September 11, 2001 Shift Manager Log April 25, 2001 CR 00077724 U-1 Secondary Chemistry Action Levels Due To 1B CW Box Leak October 2, 2001 CR 00078419 Increased Number of Unplanned Power Changes October 10, 2001 CR 00102052 RETDAS Software Disparity March 28, 2002 CR 00108504 Public Dose PI Notebook Contains Inaccurate Supporting Data May 16, 2002 LSA-AA-2140 Monthly Performance Indicator Data Elements for Occupational Exposure Control Effectiveness Revision 2 RS-AA-122-115 Performance Indicator - Occupational Exposure Control Effectiveness Revision 2 LSA-AA-2150 Monthly Performance Indicator Data Elements for RETS/ODCM Radiological Effluent Occurrences Revision 2 4OA2 Identification and Resolution of Problems Apparent Cause Evaluation 98784-01 B1R11 Shutdown Events and Unexpected Occurrences March 12, 2002 98784 B1R11 Shutdown Events and Unexpected Occurrences March 12, 2002 98775 Unit 1 Steam Dump Operation Inappropriate Response March 12, 2002

98912 Early Replacement of C/O delayed B1R11 SI Test March 12, 2002 99832 Unplanned BOL-Entry 2PR28-Bus 143 Outage March 18, 2002 99665 B1R11-Bus 143 Outage: Loss of Unit 2 RCDT Level Indication March 18, 2002 100065 Bus 143 Outage with Emrg. Lighting OOS &

No Temp Lighting March 19, 2002 100327 Summary of Bus 143 Outage items during B1R11 March 21, 2002 BOP AP-104 Bus 143 Outage while in Mode 5, 6, or Defueled Revision 0 4OA3 Event Follow-up Shift Manager Log March 29, 2002 Shift Manager Log April 4, 2002 WO 99267655 Main Steam Isolation Valves Full Stroke March 25, 2002 1BOSR 7.2.1-1 U-1 Main Steam Isolation Valve Operability Test Revision 2 CR 00102358 Missing Rubber Insulator on 2A DG Fuel Oil Supply Line (NRC Identified)

April 4, 2002 ER-AA-520 Instrument Performance Trending Revision 0 AR 98531 Main Steam Safety Valve Test Failure BMP 3114-15 Main Steam Safety Valve Verification of Lift Point Using Furmanites Trevitest Equipment Revision 12, May 5, 2000 Licensee Letter Request for Notice of Enforcement Discretion and Exigent Licensee Amendment for Technical Specification 3.7.2, Main Steam Isolation Valves (MSIVs)

October 1, 2001 NRC Letter Notice of Enforcement Discretion for Exelon Generation Company, LLC, Regarding Byron Station, Unit 1 and 2 October 3, 2001 Action Item 99785 &

100114 Multiple Failures of Pressurizer Safeties April 3, 2002

Document Procedure NWS-T-29 NWS Safety Valve Test Procedure for Commonwealth Edison Company - Byron Nuclear Station Crosby Pressurizer Safety Valves Revision 2 Letter Proposed Amendment to Technical Specifications for Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos.

50-454 and 50-455 June 8, 1987 Drawing Crosby Safety Relief Valves Used in Byron Pressurizer December 12, 1991 Drawing Dresser Main Steam Safety Valves Used at Byron Station February 15, 1975 CR B2000-02827 Pressurizer Safety As Found Test Lift Pressure Outside Limits September 30, 2000 LER 2002-02-00 Two of Three Pressurizer Safety Valve Relief Tests Exceeded Required Tolerance Due to Setpoint Drift May 16, 200 NUREG-1022 Event Reporting Guidelines 10 CFR 50.72 and 50.73 Revision 2 2BOSR 7.2.1-1 Un it 2 Main Steam Isolation Valve Operability Test June 27, 2002 1 - Condition Report issued as a result of the inspection