IR 05000455/1986002

From kanterella
Jump to navigation Jump to search
Insp Rept 50-455/86-02 on 860106-10.No Violation or Deviation Noted.Major Areas Inspected:Preoperational Testing QA Activities
ML20137J384
Person / Time
Site: Byron 
Issue date: 01/16/1986
From: Hawkins F, Walker H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20137J382 List:
References
50-455-86-02, 50-455-86-2, NUDOCS 8601220423
Download: ML20137J384 (3)


Text

--

.

.

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-455/86002 Docket No. 50-455 License No. CPPR-131 Licensee: Comonwealth Edison Company Post Office Box 767 Chicago, IL 60690 Facility Narre: Byron Station, Unit 2 Inspection At: Byron Site, Byron, Illinois Inspection Conducted: January 6-10, 1986 g. [

/4[f4 Inspector:

H. A. Walker

1 i-

-

Approved By:

F.

Hawkins, Chief 1/l4/%

'

Quality Assurance Programs Section Date Inspection Sumary

,

Inspection on January 6-10, 1986 (Report No. 50-455/86002(DRS))

Areas Inspected: Unannounced inspection by one regional inspector of preoperational testing quality assurance activities. The inspection involved a total of 34 inspector-hours onsite.

It was conducted in accordance with NRC inspection procedure No. 30703B and No. 35301B.

Resul ts: No violations or deviations were identified.

8601220423 860114 PDR ADOCK 05000455 G

PDR

-

-

.

.

DETAILS 1.

Persons Contacted Commonwealth Edison Company (CECO)

  • E. Briette, QA Engineer W. B. Burkamper, Operations QA Supervisor A. J. Chernick, Compliance Supervisor
  • P. Devine, Unit 2 Testing
  • E. E. Falb, Unit 2. Testing Superintendent

,

J. Lungan, tumpliance Staff

  • D. Milroy, Unit 2 Startup Engineer

,

!

R. Ploniewicz, Production Superintendent j

  • R. E. Querio, Byron Station Manager j.
  • A. Rosenbach, QA Engineer
  • R. Tuetken, Startup Superintendent U. S. Nuclear Regulatory Commission (NRC)
  • J. Hinds, Jr., Senior Reactor Inspector

,

J. A. Malloy, Resident Inspector

,

2.

Preoperational Testing Quality Assurance l

This inspection involved a review of the quality assurance program used for preoperational testing. Program implementation was also reviewes.

'

Compliance with regulatory requirements and quality assurance program

ccamitments was verified. The inspection was performed by observing work

activities, conducting personnel interviews and reviewing applicable i

procedures and records. Audits and surveillances of pre-test, testing and post-testing activities by the quality assurance organization were reviewed.

Test evaluations and reviews by the operations technical staff,

'

as well as methods used for documenting, tracking and resolving test

deficencies were also included in the inspection.

.

Preoperational testing for Byron Unit 2 is performed by systems test engineers (STEs) assigned to the operations technical staff. Pre-test

reviews and systems walk-downs are conducted at the time of system l

turnover to determine their status. This status is reviewed by STEs to i

determine system testability and the impact of incomplete or nonconforming

!

items on testing. Deficiencies noted prior to and during testing are documented on a deficiency form. Open and closed deficiency forms are included as a part of the test package. After testing is complete, the test is evaluated by the responsible STE.

This evaluation is documented i

and included in the test package.

The test package is then reviewed by

,

the cognizant group leader and the Test Review Board (TRB). These reviews j

,

,

I

.

-

-

.

..

.

include verification that the test is complete, test commitments have been met, retesting has been performed as required, and that open deficiencies are adequately docunented.

Deficiencies are tracked until appropriate action has been taken, the action has been verified and the deficiency closed.

The operations quality assurance organization performs either ardits or surveillances of test procedures prior to testing, selected portions of inprocess testing and completed test packages after testing is completed.

During this inspection the inspector reviewed several test packages to verify that accurate and appropriate reviews had been performed. Review checklists for both the TRB and the testing group leader were revicwed.

Records of preoperational testing audits and surveillances were reviewed, as well as the qualifications of the personnel performing the acdits and surveillances.

The inspector also irterviewed several systems test engineers and TRB members. Personnel interviewed appeared to be technically qualified and knowledgeable of preoperational testing requirements and the test review process. Records of preoperational testing audits and surveillances, and qualifications of personnel performing the audits and surveillances, were acceptable.

There were no violations or deviations noted.

3.

Exit Meeting The inspector met with licensee representatives (denoted in paragraph 1)

at the Byron Plant on January 10, 1986, and summarized the purpose, scope ar.d findings of the inspection. The inspector discussed the likely informational content of the inspection report with regard to documents or processes reviewed by the inspector during the inspection. The licensee did not identify any such documents or processes as proprietary.

.

,