IE Insp Repts 50-348/82-24 & 50-364/82-23 on 820913-17.No Noncompliance Noted.Major Areas Inspected:Radiation Protection
ML20027E557
Person / Time
Site: Farley  
Issue date: 10/05/1982
From: Barr K, Peery W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20027E549 List:
References
50-348-82-24, 50-364-82-23, NUDOCS 8211150490
Download: ML20027E557 (4)


Text

. _ _

. - -

-

p# RE%q'o UNITED STATES e

'

NUCLEAR REGULATORY COMMISSION

,

,g

,.

o REGloN ll

i$

101 MARIETTA STREET.N.W.

o ATLANTA, GEORGI A 30303

'%,,,,,/

October 6, 1982 Report Nos. 50-348/82-24 and 50-364/82-23 Licensee: Alabama Power Company 600 North 18th Street Birmincham, AL 35291 Facility Name:

Farley 1 and 2 Docket Nos. 50-348 and 50-364 License Nos. NPF-2 and NPF-8 Inspection at Farley si e near Dothan, Alabama

~ / 82, Inspector.

-

/

W. W Peery

)

Date' signed Approve by -

M

/I!

h 7 K. Barr, ec n Chief I

Date Signed

Technical Inspection Bran :h Division of Engineering and Technical Programs SUMftARY Inspection on September 13-17, 1982 Areas Inspected This routine, unannounced inspection involved 32 inspector-hours on site in the area of radiation protection.

Results

Of the areas inspected, no violations or deviations were identified.

i l

l i

' 8211150490 821006' ~

j gDRADOCK 0500034g

'

PDR I

-

- _ - -.

-

.

.*

REPORT DETAILS 1.

Persons Contacted Licensee Employees

  • W. G. Hairston, Plant Manager
  • J. D. Woodard, Assistant Plant Manager
  • C. D. Nesbitt, Technical Superintendent
  • H. M. McClellan, Generating Plant Engineer-Superivsor
  • W. G. Wade Supervisor - SAER
  • M. W. Mitchell, Chemistry and Health Physics Section Supervisor-
  • J. P. Higginbotham, Environmental Engineer W. Gripentog, Chemistry and Health Physics Supervisor Other licensee employees contacted included three technicians.

NRC Resident Inspector W. H. Bradford, Senior Resident Inspector

  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on September 17, 1982, with those persons indicated in paragraph 1 above.

3.

Licensee Action on Previous Enforcement Matters Not inspected.

Unresolved Items Unresolved items were not identified during this inspection.

5.

Instruments and Equipment The inspector verified the availability and calibration of instruments and that appropriate equipment was available. No violation was identified.

6.

Exposure Control The inspector reviewed the licensee's records of external and internal exposures and observed no exposures in excess of applicable limits.

The record revealed elevated exposures for five mechanical maintenance depart-ment personnel up to a maximum of 1495 mrem for the fourth quarter of 1981.

A

-

--

-_

, _ _. - -

- _ _ _.

--

_-

.

- _ -.

-

..- - - -...

.

..

-.

-

_

_

O

,

-

i

i i

!

Form NRC-4 or equivalent was established for these individuals. A licensee

!

representative stated that the exposures resulted from the Unit I refueling involving steam generator activities and work around the reactor head. The licensee's ALARA program includes plans to reduce such exposures including i

the addition of shielding for the reactor head. No violations or deviations were identified in the areas of external and internal exposures.

7.

Posting, Labeling and Control I

During tours of Unit 1 and 2 the inspector observed posting, labeling and control being exercised for high radiation areas.

No violations were

,

identified.

8.

Surveys The inspector reviewed records of routine and special surveys including surveys associated with Radiation Work Permits and airborne survey results.

The inspector also performed independent radiation measurements and compared

'

the findings with licensee recorded and posted survey results and found acceptable comparisons. No violations were identified.

!

9.

Notifications and Reports

-

Through discussion and record review the inspector determined that the j

licensee has complied with the notification and reporting requirements of 10 CFR 20 and Technical Specifications.

i l

10.

Inspection of Facilities l

l The inspector observed support facilities and activities as follows:

Radiochemistry laboratories Counting rooms

.

Access points to restricted and radiation areas Change rooms Personnel decontaminution areas Equipment and laundry decontamination area

.

Radioactive material storage areas

,

High radiation area controls Activity under a Radiation Work Permit No violations associated with the facilities were observed. The activity

observed under a Radiation Work Permit involved an entry to Unit I contain-ment. No violations were observed.

11.

Radioactive Effluent Releases - Liquid and Gaseous l

The inspector reviewed licensee records of liquid and gaseous releases and observed that limits on liquid and gaseous effluents have been met and no violations were identified.

I

__

-

--

-_.

.

..

,,.

_

12. Additional Records Review The inspector reviewed additional records as follows:

Scaled source leak tests Portable instrument calibrations Radwaste shipment records Fixed instrument calibrations High radiation and contamination control areas Radiation Work Permit Whole body counting records No violations were identified.

__

__