-. - - - - - - - - _. - - - _ _ - _ _ - - _ - - - _ _ _ _ - - - - -
-
. - - - - - -
e
'O
+
_[#4t>#[s%,A%
t UNITED STATES '
NUCLEAR REGULATORY COMMISSION
,
'
O w.
g
'
REGION IV
o " * * * * +0[.
611 RYAN PLAZA DRIVE, SulTE 400
,s t
AR LINGTON, TEXAS 76011-8064 W,Y 2 6 1998 C. Randy Hutchinson, Vice President Operations Arkansas Nuclear One Entergy Operations, Inc.
1448 S.R. 333 Russellville, Arkansas 72801-0967.
SUt3 JECT:
RESPONSE TO iJRC INSPECTION REPORT 50-313/98-03; 50-368/98-03
Dear Mr. Hutchinson:
,
,
Thank you for your letter of May 18,1998, in response to our April 17,1998, letter and
!
!.
Notice of Violation conceming the failure to update posted radiological information. We have reviewed your reply and find it responsive to the concerns raised in our Notice of Violation. We will review the implementation of your corrective actions during a' future inspection to determine
!
.
. that full compliance has been achieved and will be maintained.
/
Sincerely,
[
0
<
- .
Elmo E. Collins, Chief Project Branch C Division of Reactor. Projects
. Docket Nos.: 50-313 l
50-368-License Nos.: DPR-51 NPF-6
/
cc:
I
. Executive Vice President '
e
.. & Chief Operating Officer
'
. Entergy Operations, Inc.
j P.O. Box 31995
- Jackson, Mississippi 39286-1995 f
WO6010386 990526
~"
PDR= ADOCK 05000313
PDR a
i
_ - _ - _ _ - _ - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ - - - _ - _ - _ - _ _ - _ _ _ _ - _ _ _ _ - _ - - _
,
.:
e
...
Entergy Operations, Inc.
-2-Vice President Operations Support i
Entergy Operations, l'nc.
P.O. Box 31995-1 Jackson, Mississippi.39286 L Manager, Washington Nuclear Operations ABB Combustion Engineering Nuclear-Power 12300 Twinbrook Parkway, Suite 330 :
Rockville, Maryland 20852 ~
County Judge of Pope County.
Pope County Courthouse Russellville, Arkansas '72801 Winston & Strawn 1400 L Street, N.W.
Washington, D.C. 20005-3502 David D. Snellings, Jr., Director
~
Division of Radiation Control and Emergency Manager'ent -
.
!
'4815 West Markham Street, Mail Slot 30 Little Rock, Arkansas 72205-3867 Manager Rockville Nuclear Licensing j
Framatome Technologies-s1700 Rockville Pike, Suite 525
,
Rockville, Maryland 20852
!
i-i I
..
!
l
,
!..
.
I '.
.
l
!
.
l Entergy Operations, Inc.
-3-MAY 2 61998 I
l bec to DCD, bec distrib. by RIV:
Regional Administrator Resident inspector i
DRP Director MIS System
!
Branch Chief (DRP/C)
RIV File j
Project Engineer (DRP/C)
DRS-PSB
!
Branch Chief (DRP/TSS)
'
I i
l
l l
'
,
-
l l
l f
- DOCUMENT NAME: R:\\_ANO%N803AK.KMK j
To receive copy of document, indicate in box: "C" = Copy wRhout enclosures "E" = Copy with enclosures "N" = No copy
,
'
RIV:C;QRP/C l
'
EE,Coliikidf
)
GJj198 l
OFFICIAL RECORD COPY i
J i
a,'
-'
'
..J
.. _
_ _
._
_ _ _ _. _.
.__
_
_____________-__-____-_ - - - - - -
,
,
.
Ent rgy oper:tions,Inc.
,
,
1448 S.R. 333
RsseMe AR 72801 Tel501858-5000
,,
l
/
..
'10CFR2.201
.._~,;_
,9
,
Oifpg
/
May 18,1998
/..
_g "/
n OCAN059803
.
U. S. Nuclear Regulatory Conunission
~ ~ ~,
Document Control Desk, OPI-17 Washington, DC 20555
,
Subject:
Arkansas Nuclear One - Units 1 and 2 Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPF-6 Response To Inspection Report 50-313/98-03;50-368/98-03 Gentlemen:
Pursuant to the provisions of 10CFR2.201, attached is the response to the Notice of ViolaCon en.IstW wills ilm ANG Radiolugid Factc;ction Prog..un.
Should you have any questions or comments, please call me at 501-858-4601.
Very truly yours, d/ ~ $
l h BET Dale E. James Acting Director, Nuclear Safety DEJ/mkg Attachment 9T-145(
nDono a n
.
U hWh7
U. S. NRC
.
May 18,1998
-
-
0CAN059803
,_
,
.,
,
cc:
Mr. Ellis W. Merschoff Regional Administrator U.S. Nuclear Regulatory Commission RegionIV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector
!
Arkansas Nuclear One P.O. Box 310
.
Lendon, AR72847 l
Mr. William D. Reckley NRR Project Manager Region IV/ANO-1 & 2 U.S. Nuclear Regulatory Commission NRR Mail Stop 13-H-3 One White Flint North 11555 Rockville Pike Rockville, MD 20852
.
l l
.-
l
.
.
f.
Attachment to
'.
OCAN059803
.
- ,
,Page1cf3
'
~
NOTICE OF VIOLATION During an NRC inspection conducted on February 15,1998, through March 28,1998, one violation of NRC requirements was identined. In accordance with the " General Statement of Policy ad Procedure for NRC Enforcement Actions," NUREG-1600, the violationis listed below.
Unit 2 Technical Specification 6.8.1.a etates, in part, that written procedures shall be established, innpl=aa*( and maintained covering the applicable procedures recommended in Appendix A ofRegulatory Guide 1.33, Revision 2, dated February 1978.
Regulatory Guide 1.33, Appaamv A, Section 7.e.2, includes radiation l
protection procedures for radiation surveys Procedure 1012.018, Revision 3, " Administration of Radiological Surveys," Step 6.1.2, states, in part, " Observe the following requirements when conducting any survey.... Update the radiological information posting located outside of the room or cubicle where the survey was coaAmed as applicable."
Contrary to the above, the licensee failed to update the radiological information posting at the entrance of High Pressure Safety Injection Pump Room A to reflect the results of radiological surveys performed between February 21 and March 2, 1998.
This is a Severity Level IV violation (Supplement IV) (50-368/9803-03).
!
Response to Notice Of Violation 313/9803-03
)
l (1) Reason for the violation; I
On March 3,1998, the ANO resident NRC inspector observed that a radiological information posting outside train "A" shutdown cooling pump room, referred to as
'
l the high pressure safety injection pump room "A" in the NRC report, had not been updated subsequent to a chemical cleaning of the reactor coolant system (RCS) at i
the t@ *=g of ANO-2 midcycle outage 2P98-1. The chemical cleaning of the l
RCS resulted in the release and removal oflarge amounts of radioactive corrosion j
products from the RCS and an overall reduction in radiation levels. Chemical cleaning has the potential of altering the radiological survey readings recorded on i
radiological information postings in the affected areas. During chemical cleaning the affected areas of the plant are posted as high radiation areas to restrict personnel access until the cleaning process is completed. The affected areas of the plant are re-surveyed prior to removal of the high radiation area postings.
Procedure 1012.018, Administmt/<m ofRadiological Sk rveys, requires radiological survey information recorded on radiological information postings be updated, as i
e
_. _.
.._....n.
.. _. _
,
Attachment to
'
OCAN059803
.
-
(
Page 2 cf3
'
applicable.
The term "as applicable" is not defined by Procedure 1012.018.
Interviews with radiation protection (RP) personnel revealed an inconsistency in the interpretation of when the rcom/ area survey results should be updated. The RP technicians responsible for the survey of the shutdown cooling pump room following chemical cleaning of the RCS did not consider updating the room / area survey results. With exception to train "A" shutdown cooling pump room, the dose rates at the time of deposting were not significantly different than the dose rates shown on the routine monthly surveys. Train "A" shutdown cooling pump room dose rates were approximately one mrem /hr to 18 mrem /hr higher at the time the room was deposted from a high radiation area in comparison to dose rates prior to chemical cleaning of the RCS. At the time of the NRC inspector's observation, train "A" shutdown cooling pump room dose rates were approximately one mrem /hr to seven mrem /hr higher than before chemical cleaning of the RCS.
The reason for the violation is that management expectations for revising radiological information postings as radiological conditions change were not well defined or understood. Current instructions for the maintenance and revision of radiological ' formation postings within radiologically controlled areas do not m
contain explicit guidance for when survey data must be updated.
!
(2) Corrective steos that have been taken and the results achieved:
"A" shutdown cooling pump room was resurveyed and the radiological information l
posting wa. ppdnted. Ai'ition !'y, other rooms affected by the chemin! cleaning
process were surveyed and the respective radiological information postings updated.
A plan for preventing this condition from recurring during ANO-1 refueling outage IR14 was developed and implemented.
RP personnel were appraised of management expectations regarding updating radiological information postings.
(3) Corrective stens that will be taken to avoid further violations:
Radiation vrotection Department Standing Order 004, Performance and Review of Radiological Surveys, will be revised by September 30, 1998, to provide more
explicit instructions regarding rnaintenance and revision requirements for radiological i
survey data at ANO.
Procedures 1012.018, Adninisaation of Radiological Surveys, and 1601.301, Radiological Surwys, will be revised to establish more consistency between ANO and other Entergy sites regarding maintenance and revision of radiological survey data posted in radiological control aress. The procedure revisions and associated training will be completed by September 30,1998.
>
'
Attachment to
,
OCAN059803
...
.
.
ge 3 of 3 Pa l
.
.
- (4) Date when full compliance will be achieved:
Full compliance was achieved on March 3,1998, when the train "A" shutdown cooling pump room was resurveyed and the radiological ' formation posting was m
updated.
- i
.
i
_ _ _ _ _ _ _ _ _ _ _ _ _. _
_ _ _ _ _ _ _
d A
..
.
Entergy Operations, Inc.
-3-MAY 2 61998 DDEQQg)
bec distrib. by RIV:
Regional Administrator Resident inspector DRP Director MIS System Branch Chief (DRP/C)
RIV File Project Engineer (DRP/C)
DRS-PSB Branch Chief (DRP/TSS)
!
DOCUMENT NAME: R:\\_ANO\\AN803AK.KMK To receive copy of document, Indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy RIV:C;ORP/C l
l l
l l
EF,Cofffri(df
,
611/98 l
OFFICIAL RECORD COPY
-