IR 05000280/1989013

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-280/89-13 & 50-281/89-13 on 890402-29.No Violations or Deviations Noted
ML18153B760
Person / Time
Site: Surry  
Issue date: 05/30/1989
From: Fredrickson P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML18152A226 List:
References
NUDOCS 8906190155
Download: ML18153B760 (1)


Text

I -*

M/,Y 3 O 1989 Virginia Electric and Power Company

- ATTN:

Mr. W. R. Cartwright, Vice President, Nuclear Operations 5000 Dominion Boulevard Glen Allen, VA 23060 Gentlemen:

SUBJECT:

NRC INSPECTION REPORT NOS. 50-280/89-13 AND 50-281/89-13 o-J2F,*c_ ;~;

This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by W. E. Holland, L. E. Nicholson, and J. W. York, on April 2 - 29, 198 The inspection included a review of activities authorized for your Surry facilit At the conclusion of the inspection, the findings were discussed with those members of your staff identified in the enclosed inspection repor Areas examined during the inspection are identified in the_ repor Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities in progres Within the scope of ttJe inspection, no violations or deviations were identifie In accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and its enclosures will be placed in the NRC Public Document Roo Should you have any questions concerning this letter, please contact u PDR ADOCK 05000280 G

PNU Enclosure:

NRC Inspection Report cc w/encl:

M. R. Kansler, Station Manager R. F. Saunders, Manager - Nuclear Programs and Licensing Commonwealth of Virginia bee w/encl:

NRC Resident Inspector Document Control Desk R~

SShaeffer 05~6/89

Sincerely, (Original signed by ARHerdt/for)

Paul E. Fredrickson, Acting Chief Reactor Projects Branch 2 Division of Reactor Projects