IR 05000255/1986025

From kanterella
Jump to navigation Jump to search
Partially Withheld Safeguards Insp Rept 50-255/86-25 on 860818-21 (Ref 10CFR73.21(c)(2)).Violation Noted:Failure to Control Access to Protected Area
ML20214N309
Person / Time
Site: Palisades Entergy icon.png
Issue date: 09/12/1986
From: Belanger J, Christoffer G, Creed J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20214N294 List:
References
50-255-86-25, NUDOCS 8609160233
Download: ML20214N309 (1)


Text

.

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-255/86025(DRSS)

Docket No. 50-255 Licensee: Consumers Power Company 212 West Michigan Avenue Jackson, MI 49201 Facility Name: Palisades Nuclear Plant Inspection At: Palisades Site, Covert, MI Inspection Conducted: August 18-21, 1986 Date of Last Physical Security Inspection: May 5-8 and 12, 1986 Type of Inspection: Unannounced Physical Security and Allegation Follow-up Inspectors: 4 L. brws q[h/J6 J. 'L. Belangeld Dat'e Physical Security Inspector Mb 8h

. M. Christoffer Dat'e P ysical Security Inspector Approved By:

86 R. Creed, Chief Date afeguards Section Inspection Summary Inspection on August 18-21, 1986 (Report No. 50-255/86025(DRSS)J Areas _ Inspected:

Included a review of previous inspection findings and ToTlow-up on an allegation received by the resident inspector.

Results:

Five of 11 previously identified violations and open items were closed. The allegation was substantiated, resulting in one violation in the following area:

Access Control - personnel:

The licensee failed to adequately control access to the protected area in accordance with established procedures. (Section 4 Report Details)

(Details - UNCLASSIFIED )

8609160233 860912 Enclosure contains ADOCK 0500

{DR Upon separation this pago is Decontrolled

.

-

-

-

-

-

-