_ _

-

!

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-255/86016(DRSS)

Docket No. 50-255 License No. DPR-20 Licensee:

Consumers Power Company 212 West Michigan Avenue Jackson, MI 49201 Fa.:ility Name: Palisades Nuclear Plant Inspection At:

Palisades Site, Covert, MI Inspection Conducted: May 5-8 and 12, 1986 Date of Last Physical Security Inspection: October 21-24, 1985 Type of Inspection: Unannounced Physical Security i

Inspectors:

4 L. Oafavte r d,/5/ff, J.' L. Belanger Date Physical Security Inspector f

-

LL.'?

L.- -

b

'

'

'G. M. Christoffer il Date Physical Security Inspector

,

Approved By:

O

8'

'

. R. Creed, Chief Date Safeguards Section l

Inspection Summary

'

Inspection on May 5-8, and 12,1986 (Report No. 50-255/86016(DRSS))

Areas Inspected:

Included a review of Security Plan and Implementing I

procedures; Management Effectiveness; Security Organization; Records and Reports; Testing and Maintenance; Locks, Keys and Combinations; Physical Barriers - Protected Area; Physical Barriers - Vital Areas; Security System Power Supply; Lighting; Compensatory Measures; Assessment Aids; Access Control

- Personnel; Access Control - Packages; Access Control - Vehicles; Detection Aids - Vital Areas; Communications; Safeguards Contingency Plan Implementation Review; and Safeguards Information. The inspectors also reviewed the licensee's actions regarding an open item relating to vital area doors.

i

!

Results: Of the 19 r.reas inspected, two violations were identified in the following areas:

8606160110 860609 Inclosuro Centning

?

$

"

r glffl0A ns Page is Decontrolled

-

.

1.

Access Control - Vehicles / Packages: The licensee failed to adequately search the cargo area of a vehicle entering the protected area.

(Section 11, Report Details).

2.

Safeguards Information: The licensee failed to properly protect some Safeguards Information.

(Section 14, Report Details).

One " Unresolved Item" was identified with respect to the capabilities of an assessment system. (Section 8, Report Details).

The open item relating to vital area doors from the previous security inspection report continues to remain open.

The licensee failed to accomplish the actions to which they had committed. (Section 2, Report Details).

Attachment: Report Details (Unclassified Safeguards Information).

.

SFicy * % ains

  • '

Upon se,$9S I'fCR!l T200isDcconlt

parag g j