05000261/FIN-2010011-06
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Translate Vendor Recommendations Into Procedures for 480V Circuit Breakers |
Description | The team identified a Green NCV of 10 CFR 50, Appendix B, Criterion V, Procedures, Instructions and Drawings, for failure to follow procedure EGRNGGC- 006, Vendor Manuals, which requires performance of reviews to determine technical accuracy and potential changes to procedures, processes or equipment; specifically for safety related 480V Breakers and reactor trip breakers. The licensee performed a gap analysis, reviewed the discrepancies, and concluded that they did not impede the ability of the breakers from performing their associated function. Further actions are being tracked in the corrective action program under NCRs 422184 and 422976. The team concluded that the failure to perform reviews to determine technical accuracy and potential changes to procedures for circuit breaker vendor manual changes was a performance deficiency. This finding is more than minor because it affects the mitigating systems cornerstone objective to ensure the reliability, availability, and capability of systems that respond to initiating events and is associated with the attribute of procedure quality, in that procedure inconsistencies were identified in procedures MST-012-1, Maintenance and Testing of A Reactor Trip Breaker, and PM-466, Westinghouse Type 50DH350E 1200 Amp 4160V Air Circuit Breaker Maintenance. This finding also closely parallels IMC 0612, Appendix E, Example 4.a., in that the procedure discrepancies indicate that the licensee routinely failed to perform reviews EGRNGGC- 006, Vendor Manuals, which requires performance of reviews to determine technical accuracy and potential changes to procedures, processes or equipment. The team determined the finding was of very low safety significance because it was a design deficiency that did not result in a loss of operability or functionality. The team also evaluated the finding for cross-cutting aspects and determined it to involve the area of Problem Identification and Resolution associated with Operating Experience for the licensees failure to thoroughly evaluate vendor recommendations, as well as NRC Information Notice 2008-02 which identified an issue relating to improper maintenance of circuit breakers involving failure to follow vendor maintenance recommendations P.2(b). |
Site: | Robinson |
---|---|
Report | IR 05000261/2010011 Section 1R21 |
Date counted | Dec 31, 2010 (2010Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | S Walker G Skinner M Yeminy S Sandal B Desai J Eargle P Braxton |
CCA | P.5, Operating Experience |
INPO aspect | CL.1 |
' | |
Finding - Robinson - IR 05000261/2010011 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Robinson) @ 2010Q4
Self-Identified List (Robinson)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||