| Title | Failure to Take Appropriate Corrective Action for the Charging System While in Maintenance Rule (a)(1) Status |
| Description | Green. An NRC-identified finding of very low safety significance and an associated NCV of Title 10 of the Code of Federal Regulations (CFR) 50.65(a)(1) was identified for the failure to take appropriate corrective actions for the charging system, while in Maintenance Rule (a)(1) status, when performance or condition goals were not met. Specifically, on April 2, 2015, the front cap of the B charging pump cracked, causing volume control tank (VCT) level and pressure to lower, most likely due to excessive local cavity pressures in the pump caused by the suction accumulator pressure being out of specification. Accumulator pressures being out of specification, which causes pressure oscillations and vibrations in the charging pumps and their associated suction and discharge piping, was a similar cause to previous maintenance rule system functional failures that occurred in 2013 and 2014, which transitioned the system to (a)(1) status in July 2014. The licensee documented the issue in their corrective action program (CAP), conducted an equipment apparent cause evaluation (EACE) for the most recent failure, and revised the Maintenance Rule (a)(1) Action Plan to address the on-going issues with the suction and discharge accumulators. The inspectors determined that the performance deficiency was more than minor in accordance with IMC 0612 because it was associated with the Equipment Performance attribute of the Mitigating Systems Cornerstone and adversely impacted the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The charging system provides the critical safety functions of pressure and inventory control in the emergency operating procedures. The finding screened as having very low safety significance (i.e., Green) based on answering No to all the screening questions under the Mitigating Structures, Systems, and Components (SSCs) and Functionality section of the significance determination process (SDP). The finding had a cross-cutting aspect of Evaluation in the Problem Identification and Resolution area. Specifically, the organization did not thoroughly evaluate previous data on the suction and discharge accumulators pressures being out of specification and what affect that may have on the system. Also, when the accumulator pressures were found out of specification, sometimes that information was not documented in condition reports (CRs), nor were the preventive maintenance (PM) frequencies re-evaluated in a technical and rigorous manner to ensure the correct PM activities were being conducted on these components in a timely manner to assure system reliability. |
| Site: | Palisades |
|---|---|
| Report | IR 05000255/2015002 Section 1R12 |
| Date counted | Jun 30, 2015 (2015Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | A Schwab B Bostn E Duncan J Beavers J Cassidy J Corujo-Sandin J Lennartz L Rodriguez M Holmberg P Lee V Myers A Nguyen |
| Violation of: | 10 CFR 50.65(a)(1) 10 CFR 50.65 |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |