05000255/FIN-2014008-09
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure To Include The Degraded Voltage Channel Time Delay In TS Surveillance Requirement 3.3.5.2.a |
Description | The inspectors identified a finding having very low safety significance and an associated Non-Cited Violation (NCV) of 10 CFR Part 50.36(c)(3), Surveillance Requirements, for the failure to ensure the channel time delay for the degraded-voltage monitor was included in Technical Specification (TS) Surveillance Requirement (SR) 3.3.5.2.a. Specifically, the licensee failed to include in the TS SR the required time delay after the voltage relay trips before the preferred source of power is isolated and 1E electrical loads transferred to the stand-by Emergency Diesel Generators (EDGs). This finding was entered into the licensees Corrective Action Program and the licensees preliminary verification determined the degraded voltage monitors were still operable but degraded or non-conforming. The performance deficiency was determined to be more than minor because if left uncorrected, it would have the potential to lead to more significant safety concern. Specifically, by not incorporating the total time delay requirements into the Technical Specifications, (TS) the time could be changed without going through the TS change process, possibly leading to spurious trips of offsite power sources or possibly exceeding the accident analysis time is the FSAR. The inspectors determined the finding was of very low safety significance (Green) because it did not cause a reactor trip and the loss of mitigation equipment relied upon to transition the plant from the onset of the trip to a stable shutdown condition. The inspectors did not identify a cross-cutting aspect associated with this finding because the finding was not representative of the licensees present performance. |
Site: | Palisades |
---|---|
Report | IR 05000255/2014008 Section 1R21 |
Date counted | Dec 31, 2014 (2014Q4) |
Type: | NCV: Green |
cornerstone | Initiating Events |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | A Stone C Baron C Brown C Zoia H Leake J Corujo-Sandin L Rodriguez S Sheldon |
Violation of: | 10 CFR 50.36 Technical Specification |
INPO aspect | |
' | |
Finding - Palisades - IR 05000255/2014008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Palisades) @ 2014Q4
Self-Identified List (Palisades)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||