05000247/FIN-2015003-03
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Conduct Operations to Minimize the Introduction of Residual Radioactivity to the Site |
| Description | The inspectors identified a Green NCV of Title 10 of the Code of Federal Regulations (10 CFR) 20.1406(c) in that Entergy did not conduct operations to minimize the introduction of residual radioactivity into the site. Specifically, Entergy did not identify a new leak of tritium into groundwater based on monitoring well results obtained in February 2015 and did not take action to minimize the introduction of residual radioactivity into the subsurface of the site. Entergy entered this issue into their CAP as CR-IP2-2015-03806 with actions to characterize and evaluate this new leak. The issue is more than minor because it is associated with the program and process attribute of the Public Radiation Safety cornerstone, and adversely affected the cornerstone objective to ensure Entergys ability to prevent inadvertent release and/or loss of control of licensed material to an unrestricted area. In accordance with IMC 0609, Appendix D, Public Radiation Safety Significance Determination Process, the finding was determined to be of very low safety significance (Green) because the issue involved radioactive material control but did not involve: (1) transportation or (2) public exposure in excess of 0.005 rem. The finding had a cross-cutting aspect in the area of Human Performance, Problem Identification and Resolution, in that the resolutions to address the causes for the 2014 tritium leak did not include an extent of condition that recognized the February 2015 tritium spike as a new leak |
| Site: | Indian Point |
|---|---|
| Report | IR 05000247/2015003 Section 4OA2 |
| Date counted | Sep 30, 2015 (2015Q3) |
| Type: | NCV: Green |
| cornerstone | Or Safety |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Bolger A Burritt B Pinson G Newman H Gray J Furia J Stewart O Masnyk-Bailey S Barr S Rich |
| Violation of: | 10 CFR 20.1406, Minimization of contamination 10 CFR 20, Standards for Protection Against Radiation |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Indian Point - IR 05000247/2015003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2015Q3
Self-Identified List (Indian Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||