05000247/FIN-2014011-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Inadequate Analysis of Safety Injection Make-up Capabili |
Description | The team identified a finding of very low safety significance, involving a non-cited violation of Indian Point Units 2 and 3 Facility Operating Licenses Conditions 2.K and 2.H, respectively, for failure to implement and maintain in effect all provisions of the approved Fire Protection Program. Specifically, Entergy revised the safe shutdown (SSD) methodology to use the safety injection system as a credited reactor coolant system make-up source, but the thermo-hydraulic analysis used to validate the revised method was not consistent with the SSD analysis or with the operating procedures. Entergy entered this issue into its corrective action program and revised the thermo-hydraulic analysis prior to the end of this inspection to demonstrate the adequacy of the new methodology. This finding was more than minor because it was similar to Example 3.k of NRC IMC 0612, Appendix E, Examples of Minor Issues, and was associated with the Protection Against External Factors (e.g., Fire) attribute of the Mitigating Systems Cornerstone and affected the objective to ensure the reliability and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). The team performed a Phase 1 SDP screening, in accordance with IMC 0609, Appendix F, Fire Protection SDP. This finding affected the post-fire SSD category, and was determined to have a low degradation rating because a subsequent analysis verified that safety injection was sufficient to maintain the reactor coolant system sub-cooled. This finding had a cross-cutting aspect in the area of Human Performance, Documentation, because Entergy did not maintain complete, accurate, and up-to-date documentation used as critical design inputs for a thermo-hydraulic analysis. |
Site: | Indian Point |
---|---|
Report | IR 05000247/2014011 Section 4OA5 |
Date counted | Mar 31, 2015 (2015Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | |
Inspectors (proximate) | J Patel J Richmond J Rogge W Schmidt |
Violation of: | License Condition - Fire Protection |
CCA | H.7, Documentation |
INPO aspect | WP.3 |
' | |
Finding - Indian Point - IR 05000247/2014011 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2015Q1
Self-Identified List (Indian Point)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||