ML17326A639

From kanterella
Revision as of 09:11, 6 July 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
LER 80-013/03L-0:on 800307,during Normal Operation,Circuit Breaker for R-11 & R-12 Sample Pump Tripped.Caused by Failure of Rubber Spider in Lovejoy L-100 Coupling.Complete Coupling Replaced & Air Sampler Tested
ML17326A639
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 04/02/1980
From: WIZNER D G
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17326A637 List:
References
LER-80-013-03L, LER-80-13-3L, NUDOCS 8004080529
Download: ML17326A639 (2)


Text

U.S.NUCLEAR REGULATORY COMMISSION 0 Q3 4 1 1 1 1 04~Qs 25 26 LICENSE TYPE 30 57 CAT 58 SAMPLE PUMP TR I PPED.THI S CONST I TUTED INOPERABLE RAD~MON I TOR INST~NRC FORM 366 (7.77)ICENSEE EVENT REPORT 8'OATROL BLOCK: Qi{PLEASE PRINT OR TYPE ALI.REQUIRED INFORMATION)

I 6 M I D C C 2Q2 0 0-0 0 0 0 0-0 7 8 9 I ICENSEE CODE 14 15 LICENSE NUMBER CON'T~01~LQB 0 5 0 0 0 3]6 Q7 0 3 0 7 8 0 QB 0 4 0 2 8 0 Q9 7 8 60 61 DOCKET NUMBER 68 69, EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES Q10~O2 DURING NORMAL OPERATIONS THE CI RCU IT BREAKER FOR THE R 1 1 AND R 12 CHANNELS PER T.S.3.3.3.1 AND TABLE 3.3-6.THE ACTION RE UIREMENTS WERE MET.THIS EVENT HAD NO AFFECT ON PUBLIC HEALTH AND SAFETY.SIMILAR o 6 EVENTS REPORTED INCLUDE R 0 79 034/03L 0 AND FOR DOCKET NO'50 315 RO 79 0 12/03 L-0 AND 79-048/03 L-0~~OB 80 7 8 9~O9 7 8 0 SYSTEM CAUSE CAUSE COMP.VAI.VE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE~II Ql B 012~B 013 P U N P x x 8 LJQTE~z 8 9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LERIRO EVENT YEAR REPORT NO.CODE TYPE NO.Q17 REPORT~fl 0+~~i 3 U~LOD3I Ll Ll U 21 22 23 24 26 27 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRDC PRIME COMP.COMPONENT TAKEN ACTION ON PLANT METHOD HOURS+22 SUBMITTED FORM SUB.SUPPLIER MANUFACTURER Qls~~Qls~~Q20~~02\0 0 0 1I N 023~Q24~A 02s 1 2 0 028 33 34 35 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 FAILURE WAS DUE TO FAILURE OF THE RUBBER SPIDER IN THE LOVEJOY L-100 COUPLING.THE COMPLETE COUPLING WAS REPLACED AND THE AIR SAMPLER TESTED.PRESENT PLANS ARE TO REPLACE THE ENTIRE SYSTEM AS PART OF MODIFICATION 3 RFC DC 12-2448.80 7 8 9 FACILITY STATUS%POWER OTHER STATUS QP~75 B Q28~10 0 08 8 9 10 12 13 44 ACTIVITY CONTENT RELEASED OF RELEASE AMOUNT OF ACTIVITY Q~s~Z033~Z@4 NA 7 8 9 10 11 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION Q39 7~00 0 Q37 z Q38 NA 7 8 9 11 12 13 PERSONNEL INJURIES NUMBER DESCRIPTION Q41 8~pp Q48 NA 7 8 9 11 12 LOSS OF OR DAMAGE.TO FACILITY 43 TYPE DESCRIPTION 9 7 Q42 NA 7 8 9 10 PUBLICITY ISSUED DESCRIPTION 05 O~NQ44<NA 8 9 10 NAME OF PREPARER DAVID G.WIZNER METHOD OF CIISCOVERY DISCOVERY DESCRIPTION Q32 Q31 OPERATOR OBSERVAT ION 45 46 1 LOCATION OF RELEASE QB 80 80 45 80 80 goo Sopor~80 NRC USE ONLY 44 68 69 80 PHQNE.616-465-5901'XT.

398 0 0 l