LER 80-013/03L-0:on 800307,during Normal Operation,Circuit Breaker for R-11 & R-12 Sample Pump Tripped.Caused by Failure of Rubber Spider in Lovejoy L-100 Coupling.Complete Coupling Replaced & Air Sampler Tested
ML17326A639
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 04/02/1980
From: WIZNER D G
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17326A637 List:
References
LER-80-013-03L, LER-80-13-3L, NUDOCS 8004080529